Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros

Base de dados
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Mol Pharm ; 14(10): 3577-3587, 2017 10 02.
Artigo em Inglês | MEDLINE | ID: mdl-28834434

RESUMO

In this study, two dissolution models were developed to achieve in vitro-in vivo relationship for immediate release formulations of Compound-A, a poorly soluble weak base with pH-dependent solubility and low bioavailability in hypochlorhydric and achlorhydric patients. The dissolution models were designed to approximate the hypo-/achlorhydric and normal fasted stomach conditions after a glass of water was ingested with the drug. The dissolution data from the two models were predictive of the relative in vivo bioavailability of various formulations under the same gastric condition, hypo-/achlorhydric or normal. Furthermore, the dissolution data were able to estimate the relative performance under hypo-/achlorhydric and normal fasted conditions for the same formulation. Together, these biorelevant dissolution models facilitated formulation development for Compound-A by identifying the right type and amount of key excipient to enhance bioavailability and mitigate the negative effect of hypo-/achlorhydria due to drug-drug interaction with acid-reducing agents. The dissolution models use readily available USP apparatus 2, and their broader utility can be evaluated on other BCS 2B compounds with reduced bioavailability caused by hypo-/achlorhydria.


Assuntos
Acloridria/complicações , Liberação Controlada de Fármacos , Modelos Químicos , Administração Oral , Disponibilidade Biológica , Química Farmacêutica , Interações Medicamentosas , Humanos , Concentração de Íons de Hidrogênio , Solubilidade , Comprimidos
2.
Heliyon ; 10(12): e32949, 2024 Jun 30.
Artigo em Inglês | MEDLINE | ID: mdl-39021958

RESUMO

Osteoclasts are essential for bone remodeling by adapting their resorptive activity in response to their mechanical in vivo environment. However, the molecular mechanisms underlying this process remain unclear. Here, we demonstrated the role of tartrate-resistant acid phosphatase (TRAP, Acp5), a key enzyme secreted by osteoclasts, in bone remodeling and mechanosensitivity. Using CRISPR/Cas9 reporter mice, we demonstrated bone cell reporter (BCRIbsp/Acp5) mice feature fluorescent TRAP-deficient osteoclasts and examined their activity during mechanically driven trabecular bone remodeling. Although BCRIbsp/Acp5 mice exhibited trabecular bone impairments and reduced resorption capacity in vitro, RNA sequencing revealed unchanged levels of key osteoclast-associated genes such as Ctsk, Mmp9, and Calcr. These findings, in conjunction with serum carboxy-terminal collagen crosslinks (CTX) and in vivo mechanical loading outcomes collectively indicated an unaltered bone resorption capacity of osteoclasts in vivo. Furthermore, we demonstrated similar mechanoregulation during trabecular bone remodeling in BCRIbsp/Acp5 and wild-type (WT) mice. Hence, this study provides valuable insights into the dynamics of TRAP activity in the context of bone remodeling and mechanosensation.

3.
J Anal Toxicol ; 2020 Dec 05.
Artigo em Inglês | MEDLINE | ID: mdl-33277901

RESUMO

The impact of the hematocrit (HCT) on the dried blood spot's (DBS) spreading area is one of the most important hurdles which prevents the full acceptance of quantitative microsampling strategies. Several destructive- and non-destructive strategies to assess the HCT from a DBS post-sampling have been presented. Unfortunately, the current methods are either labor-intensive, require a complicated algorithm, or are not automatable. Here, we present a novel setup that permits the fully automated reflectance analysis to measure the HCT from a DBS. The underlying principle is based on the concept presented by Capiau et al. for the non-destructive single-wavelength measurement of the HCT. The novel module was embedded within the DBS-MS 500 platform to enable high-throughput analysis of hematocrit values in combination with automated DBS extraction. The novel setup was assessed and optimized for the probe to card distance, stability, anti-coagulant, spotting volume, scan number, calibration variability, accuracy, and precision. It showed excellent inter-day (≤3.7%) and intra-day (≤1.16%) precision, as well as high accuracy when analyzing authentic samples 101%±7% (range:87%-127%). Besides, the simple and straightforward application of an HCT correction for DBS was demonstrated during a pharmacokinetic study with diclofenac involving three subjects. Thereby, the sample's HCT and the HCT impact on the analyte was assessed and compensated. In conclusion, the novel setup enables quantitative analysis of non-volumetric samples in an automated fashion without compromising the concept of cost-effective, minimally invasive sampling.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA