Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 12 de 12
Filtrar
Mais filtros

Base de dados
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Anal Chem ; 87(6): 3187-94, 2015 Mar 17.
Artigo em Inglês | MEDLINE | ID: mdl-25688836

RESUMO

A fiber-based laser with a pulse duration of 435 fs and a wavelength of 1042 nm was used to vaporize biological macromolecules intact from the condensed phase into the gas phase for nanospray postionization and mass analysis. Laser vaporization of dried standard protein samples from a glass substrate by 10 Hz bursts of 20 pulses having 10 µs pulse separation and <50 µJ pulse energy resulted in signal comparable to a metal substrate. The protein signal observed from an aqueous droplet on a glass substrate was negligible compared to either a droplet on metal or a thin film on glass. The mass spectra generated from dried and aqueous protein samples by the low-energy, fiber laser were similar to the results from high-energy (500 µJ), 45-fs, 800-nm Ti:sapphire-based femtosecond laser electrospray mass spectrometry (LEMS) experiments, suggesting that the fiber-based femtosecond laser desorption mechanism involves a nonresonant, multiphoton process, rather than thermal- or photoacoustic-induced desorption. Direct analysis of whole blood performed without any pretreatment resulted in features corresponding to hemoglobin subunit-heme complex ions. The observation of intact molecular ions with low charge states from protein, and the tentatively assigned hemoglobin α subunit-heme complex from blood suggests that fiber-based femtosecond laser vaporization is a "soft" desorption source at a laser intensity of 2.39 × 10(12) W/cm(2). The low-energy, turnkey fiber laser demonstrates the potential of a more robust and affordable laser for femtosecond laser vaporization to deliver biological macromolecules into the gas phase for mass analysis.


Assuntos
Citocromos c/química , Lasers , Muramidase/química , Fibras Ópticas , Espectrometria de Massas por Ionização por Electrospray/instrumentação , Animais , Vidro/química , Aço Inoxidável/química , Fatores de Tempo , Volatilização , Água/química , Itérbio
2.
Anal Chem ; 85(14): 6667-73, 2013 Jul 16.
Artigo em Inglês | MEDLINE | ID: mdl-23751016

RESUMO

A comparison of the mass spectral response for myoglobin, cytochrome c, and lysozyme is presented for laser electrospray mass spectrometry (LEMS) and electrospray ionization-mass spectrometry (ESI-MS). Analysis of multicomponent protein solutions using nonresonant femtosecond (fs) laser vaporization with electrospray postionization mass spectrometry exhibited significantly reduced ion suppression effects in comparison with conventional ESI analysis, enabling quantitative measurements over 4 orders of magnitude in concentration. No significant charge reduction was observed in the LEMS experiment while the ESI measurement revealed charge reduction for myoglobin and cytochrome c as a function of increasing protein concentration. Conventional ESI-MS of each analyte from a multicomponent solution reveals that the ion signal detected for myoglobin and cytochrome c reaches a plateau and then begins to decrease with increasing protein concentration preventing quantitative analysis. The ESI mass spectral response for lysozyme from the mixture initially decreased, before increasing, with increasing multicomponent solution concentration.


Assuntos
Citocromos c/análise , Muramidase/análise , Mioglobina/análise , Espectrometria de Massas por Ionização por Electrospray/métodos , Espectrometria de Massas/métodos , Proteínas/análise
3.
Anal Chem ; 85(1): 296-302, 2013 Jan 02.
Artigo em Inglês | MEDLINE | ID: mdl-23215164

RESUMO

A direct, sensitive, and rapid method for the detection of smokeless powder components, from five different types of ammunition, is demonstrated using laser electrospray mass spectrometry (LEMS). Common components found in powder, such as ethyl centralite, methyl centralite, dibutyl phthalate, and dimethyl phthalate, are detected under atmospheric conditions without additional sample preparation. LEMS analysis of the powders revealed several new mass spectral features that have not been identified previously. Offline principal component analysis and discrimination of the LEMS mass spectral measurements resulted in perfect classification of the smokeless powder with respect to manufacturer.

4.
Anal Chem ; 85(7): 3629-37, 2013 Apr 02.
Artigo em Inglês | MEDLINE | ID: mdl-23452308

RESUMO

Quantitative measurements of atenolol, tioconazole, tetraethylammonium bromide, and tetrabutylammonium iodide using laser electrospray mass spectrometry (LEMS) reveal monotonic signal response as a function of concentration for single analytes, two- and four-component equimolar mixtures, and two-component variable molarity mixtures. LEMS analyses of single analytes as a function of concentration were linear over ~2.5 orders of magnitude for all four analytes and displayed no sign of saturation. Corresponding electrospray ionization (ESI) measurements displayed a nonmonotonic increase as saturation occurred at higher concentrations. In contrast to the LEMS experiments, the intensity ratios from control experiments using conventional ESI-MS deviated from expected values for the equimolar mixture measurements due to ion suppression of less surface active analytes, particularly in the analysis of the four-component mixture. In the analyses of two-component nonequimolar mixtures, both techniques were able to determine the concentration ratios after adjustment with response factors although conventional ESI-MS was subject to a greater degree of saturation and ion suppression at higher analyte concentrations.


Assuntos
Lasers , Espectrometria de Massas por Ionização por Electrospray/instrumentação , Atenolol/química , Desenho de Equipamento , Imidazóis/química , Compostos de Amônio Quaternário/química , Espectrometria de Massas por Ionização por Electrospray/métodos , Tetraetilamônio/química
5.
Anal Chem ; 84(14): 6225-32, 2012 Jul 17.
Artigo em Inglês | MEDLINE | ID: mdl-22697315

RESUMO

Laser electrospray mass spectrometry (LEMS) coupled with offline multivariate statistical analysis is used to discriminate eight phenotypes from a single plant organ class and to find potential biomarkers. Direct analysis of the molecules from the flower petal is enabled by interfacing intense (10(13) W/cm(2)), nonresonant, femtosecond laser vaporization at ambient pressure with electrospray ionization for postionization of the vaporized analytes. The observed mass spectral signatures allowed for the discrimination of various phenotypes using principal component analysis (PCA) and either linear discriminant analysis (LDA) or K-nearest neighbor (KNN) classifiers. Cross-validation was performed using multiple training sets to evaluate the predictive ability of the classifiers, which showed 93.7% and 96.8% overall accuracies for the LDA and KNN classifiers, respectively. Linear combinations of significant mass spectral features were extracted from the PCA loading plots, demonstrating the capability to discover potential biomarkers from the direct analysis of tissue samples.


Assuntos
Flores/química , Impatiens/química , Lasers , Fenótipo , Espectrometria de Massas por Ionização por Electrospray/métodos , Biomarcadores/análise , Análise Discriminante , Flores/genética , Impatiens/genética , Análise Multivariada , Análise de Componente Principal
6.
Anal Chem ; 83(18): 7115-22, 2011 Sep 15.
Artigo em Inglês | MEDLINE | ID: mdl-21774526

RESUMO

The mass spectral detection of low vapor pressure, inorganic-based explosive signatures including ammonium nitrate, chlorate, perchlorate, sugar, and the constituents contained within black powder are reported using laser electrospray mass spectrometry. The ambient pressure mass spectrometry technique combining nonresonant, femtosecond laser vaporization with electrospray postionization revealed primary and secondary signatures for trace quantities of inorganic explosives. A mixture of complexation agents in the electrospray solvent enabled the simultaneous detection of vaporized cations, anions, and neutrals in a single measurement. An offline classifier discriminated the inorganic-based explosives based on the mass spectral signatures resulting in high fidelity identification.

7.
Electrophoresis ; 31(20): 3466-74, 2010 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-20922760

RESUMO

A sensitive method was developed for the determination of the major inorganic ions in commercial mineral waters using gradient elution moving boundary electrophoresis with capacitively coupled contactless conductivity detection. This application was the first to demonstrate the separation of cations and anions simultaneously using gradient elution moving boundary electrophoresis. Seven ionic analytes (calcium, chloride, magnesium, nitrate, potassium, sodium, and sulfate) were separated in less than 7 min with detection values in the low µmol/L to sub-µmol/L range. Calculated values of the major ions in three commercial mineral waters were compared to reported values with good correlation. In another application, phosphate and arsenate were separated in less than 2 min with limits of detection of 300 and 140 nmol/L, respectively. For all standard analyses, the RSD for migration times and peak areas were under 3%.


Assuntos
Arseniatos/análise , Eletroforese/métodos , Águas Minerais/análise , Ânions/análise , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
8.
J Am Soc Mass Spectrom ; 27(3): 542-51, 2016 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-26667178

RESUMO

Direct analysis of plant and animal tissue samples by laser electrospray mass spectrometry (LEMS) was investigated using low-energy, femtosecond duration laser vaporization at wavelengths of 800 and 1042 nm followed by nanospray postionization. Low-energy (<50 µJ), fiber-based 1042 nm LEMS (F-LEMS) allowed interrogation of the molecular species in fresh flower petal and leaf samples using 435 fs, 10 Hz bursts of 20 pulses from a Ytterbium-doped fiber laser and revealed comparable results to high energy (75-1120 µJ), 45 fs, 800 nm Ti:Sapphire-based LEMS (Ti:Sapphire-LEMS) measurements. Anthocyanins, sugars, and other metabolites were successfully detected and revealed the anticipated metabolite profile for the petal and leaf samples. Phospholipids, especially phosphatidylcholine, were identified from a fresh mouse brain section sample using Ti:Sapphire-LEMS without the application of matrix. These lipid features were suppressed in both the fiber-based and Ti:Sapphire-based LEMS measurements when the brain sample was prepared using the optimal cutting temperature compounds that are commonly used in animal tissue cryosections.


Assuntos
Química Encefálica , Plantas/química , Espectrometria de Massas por Ionização por Electrospray/instrumentação , Animais , Antocianinas/análise , Carboidratos/análise , Desenho de Equipamento , Lasers , Camundongos , Fosfolipídeos/análise , Volatilização
9.
J Am Soc Mass Spectrom ; 26(5): 716-24, 2015 May.
Artigo em Inglês | MEDLINE | ID: mdl-25724375

RESUMO

The internal energy of p-substituted benzylpyridinium ions after laser vaporization using low energy, femtosecond duration laser pulses of wavelengths 800 and 1042 nm was determined using the survival yield method. Laser vaporization of dried benzylpyridinium ions from metal slides into a buffered nanospray with 75 µJ, 800 nm laser pulses resulted in a higher extent of fragmentation than conventional nanospray due to the presence of a two-photon resonance fragmentation pathway. Using higher energy 800 nm laser pulses (280 and 505 µJ) led to decreased survival yields for the four different dried benzylpyridinium ions. Analyzing dried thermometer ions with 46.5 µJ, 1042 nm pulse-bursts resulted in little fragmentation and mean internal energy distributions equivalent to nanospray, which is attributable to the absence of a two-photon resonance that occurs with higher energy, 800 nm laser pulses. Vaporization of thermometer ions from solution with either 800 nm or 1042 nm laser pulses resulted in comparable internal energy distributions to nanospray ionization.

10.
J Am Soc Mass Spectrom ; 26(5): 706-15, 2015 May.
Artigo em Inglês | MEDLINE | ID: mdl-25753972

RESUMO

Femtosecond (fs) laser vaporization is used to transfer cytochrome c, myoglobin, lysozyme, and ubiquitin from the condensed phase into an electrospray (ES) plume consisting of a mixture of a supercharging reagent, m-nitrobenzyl alcohol (m-NBA), and trifluoroacetic acid (TFA), acetic acid (AA), or formic acid (FA). Interaction of acid-sensitive proteins like cytochrome c and myoglobin with the highly charged ES droplets resulted in a shift to higher charge states in comparison with acid-stable proteins like lysozyme and ubiquitin. Laser electrospray mass spectrometry (LEMS) measurements showed an increase in both the average charge states (Zavg) and the charge state with maximum intensity (Zmode) for acid-sensitive proteins compared with conventional electrospray ionization mass spectrometry (ESI-MS) under equivalent solvent conditions. A marked increase in ion abundance of higher charge states was observed for LEMS in comparison with conventional electrospray for cytochrome c (ranging from 19+ to 21+ versus 13+ to 16+) and myoglobin (ranging from 19+ to 26+ versus 18+ to 21+) using an ES solution containing m-NBA and TFA. LEMS measurements as a function of electrospray flow rate yielded increasing charge states with decreasing flow rates for cytochrome c and myoglobin.


Assuntos
Citocromos c/química , Muramidase/química , Mioglobina/química , Ubiquitina/química , Ácido Acético/química , Ácido Acético/farmacologia , Animais , Álcoois Benzílicos/química , Álcoois Benzílicos/farmacologia , Bovinos , Galinhas , Formiatos/química , Formiatos/farmacologia , Cavalos , Indicadores e Reagentes/química , Indicadores e Reagentes/farmacologia , Lasers de Estado Sólido , Desnaturação Proteica/efeitos dos fármacos , Estabilidade Proteica/efeitos dos fármacos , Solventes/química , Espectrometria de Massas por Ionização por Electrospray , Ácido Trifluoracético/química , Ácido Trifluoracético/farmacologia , Volatilização
11.
J Am Soc Mass Spectrom ; 25(9): 1572-82, 2014 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-25012513

RESUMO

The internal energy distributions for dried and liquid samples that were vaporized with femtosecond duration laser pulses centered at 800 nm and postionized by electrospray ionization-mass spectrometry (LEMS) were measured and compared with conventional electrospray ionization mass spectrometry (ESI-MS). The internal energies of the mass spectral techniques were determined by plotting the ratio of the intact parent molecular features to all integrated ion intensities of the fragments as a function of collisional energy using benzylpyridinium salts and peptides. Measurements of dried p-substituted benzylpyridinium salts using LEMS resulted in a greater extent of fragmentation in addition to the benzyl cation. The mean relative internal energies, were determined to be 1.62 ± 0.06, 2.0 ± 0.5, and 1.6 ± 0.3 eV for ESI-MS, dried LEMS, and liquid LEMS studies, respectively. Two-photon resonances with the laser pulses likely caused lower survival yields in LEMS analyses of dried samples but not liquid samples. In studies with larger biomolecules, LEMS analyses of dried samples from glass showed a decrease in survival yield compared with conventional ESI-MS for leucine enkephalin and bradykinin of ~15% and 11%, respectively. The survival yields for liquid LEMS analyses were comparable to or better than ESI-MS for benzylpyridinium salts and large biomolecules.


Assuntos
Compostos de Benzil/química , Peptídeos/química , Compostos de Piridínio/química , Espectrometria de Massas por Ionização por Electrospray/métodos , Bradicinina/química , Encefalina Leucina/química , Desenho de Equipamento , Íons/química , Sais/química , Espectrometria de Massas por Ionização por Electrospray/instrumentação , Temperatura , Termodinâmica
12.
Bioanalysis ; 2(4): 815-27, 2010 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-21083276

RESUMO

CE has evolved as one of the most efficient separation techniques for a wide range of analytes, from small molecules to large proteins. Modern microdevices facilitate integration of multiple sample-handling steps, from preparation to separation and detection, and often rely on CE for separations. However, CE frequently requires complex geometries for performing sample injections and maintaining zone profiles across long separation lengths in microdevices. Two novel methods for performing electrophoretic separations, gradient elution moving boundary electrophoresis (GEMBE) and gradient elution isotachophoresis (GEITP), have been developed to simplify microcolumn operations. Both techniques use variable hydrodynamic counterflow and continuous sample injection to perform analyses in short, simple microcolumns. These properties result in instruments and microdevices that have minimal 'real-world' interfaces and reduced footprints. Additionally, GEITP is a rapid enrichment technique that addresses sensitivity issues in CE and microchips.


Assuntos
Eletroforese/métodos , Biologia/instrumentação , Biologia/métodos , Eletroforese/instrumentação , Eletroforese Capilar
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA