Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 23
Filtrar
1.
Anal Chem ; 95(30): 11510-11517, 2023 08 01.
Artigo em Inglês | MEDLINE | ID: mdl-37458293

RESUMO

Spontaneous conversion of aspartic acid (Asp) to isoaspartic acid (isoAsp) is a ubiquitous modification that influences the structure and function of proteins. This modification of Asp impacts the stability of biotherapeutics and has been linked to the development of neurodegenerative diseases. We explored the use of 193 nm ultraviolet photodissociation (UVPD) to distinguish Asp and isoAsp in the protonated and deprotonated peptides. The differences in the relative abundances of several fragment ions uniquely generated by UVPD were used to differentiate isomeric peptide standards containing Asp or isoAsp. These fragment ions result from the cleavage of bonds N-terminal to Asp/isoAsp residues in addition to the side-chain losses from Asp/isoAsp or the losses of COOH, CO2, CO, or H2O from y-ions. Fragmentation of Asp-containing tryptic peptides using UVPD resulted in more enhanced w/w + 1/y - 1/x ions, while isoAsp-containing peptides yielded more enhanced y - 18/y - 45/y - 46 ions. UVPD was also used to identify an isomerized peptide from a tryptic digest of a monoclonal antibody. Moreover, UVPD of a protonated nontryptic peptide resulted in more enhanced y ions N- and C-terminal to isoAsp and differences in b/y ion ratios that were used to identify the isoAsp peptide.


Assuntos
Ácido Isoaspártico , Peptídeos , Ácido Isoaspártico/análise , Ácido Isoaspártico/química , Sequência de Aminoácidos , Espectrometria de Massas/métodos , Peptídeos/química , Ácido Aspártico/química , Íons , Raios Ultravioleta
2.
Anal Chem ; 94(16): 6191-6199, 2022 04 26.
Artigo em Inglês | MEDLINE | ID: mdl-35421308

RESUMO

Isomeric peptide analyses are an analytical challenge of great importance to therapeutic monoclonal antibody and other biotherapeutic product development workflows. Aspartic acid (Asp, D) to isoaspartic acid (isoAsp, isoD) isomerization is a critical quality attribute (CQA) that requires careful control, monitoring, and quantitation during the drug discovery and production processes. While the formation of isoAsp has been implicated in a variety of disease states such as autoimmune diseases and several types of cancer, it is also understood that the formation of isoAsp results in a structural change impacting efficacy, potency, and immunogenic properties, all of which are undesirable. Currently, lengthy ultrahigh-performance liquid chromatography (UPLC) separations are coupled with MS for CQA analyses; however, these measurements often take over an hour and drastically limit analysis throughput. In this manuscript, drift tube ion mobility spectrometry-mass spectrometry (DTIMS-MS) and both a standard and high-resolution demultiplexing approach were utilized to study eight isomeric Asp and isoAsp peptide pairs. While the limited resolving power associated with the standard DTIMS analysis only separated three of the eight pairs, the application of HRdm distinguished seven of the eight and was only unable to separate DL and isoDL. The rapid high-throughput HRdm DTIMS-MS method was also interfaced with both flow injection and an automated solid phase extraction system to present the first application of HRdm for isoAsp and Asp assessment and demonstrate screening capabilities for isomeric peptides in complex samples, resulting in a workflow highly suitable for biopharmaceutical research needs.


Assuntos
Espectrometria de Mobilidade Iônica , Ácido Isoaspártico , Cromatografia Líquida , Espectrometria de Mobilidade Iônica/métodos , Ácido Isoaspártico/análise , Espectrometria de Massas/métodos , Peptídeos
3.
J Org Chem ; 84(8): 4763-4779, 2019 04 19.
Artigo em Inglês | MEDLINE | ID: mdl-30557503

RESUMO

A robust process to manufacture AMG 232 was developed to deliver drug substance of high purity. Highlights of the commercial process development efforts include the following: (i) use of a novel bench-stable Vilsmeier reagent, methoxymethylene- N, N-dimethyliminium methyl sulfate, for selective in situ activation of a primary alcohol intermediate; (ii) use of a new crystalline and stable isopropyl calcium sulfinate reagent ensuring robust preparation of a sulfone intermediate; (iii) development of a safe ozonolysis process conducted in an aqueous solvent mixture in either batch or continuous manufacturing mode; and (iv) control of the drug substance purity by crystallization of a salt rejecting impurities effectively. The new process was demonstrated to afford the drug substance (99.9 LC area %) in 49.8% overall yield from starting material DLAC (1).


Assuntos
Acetatos/síntese química , Ozônio/química , Piperidonas/síntese química , Acetatos/química , Acetatos/isolamento & purificação , Estrutura Molecular , Piperidonas/química , Piperidonas/isolamento & purificação
4.
Anal Chem ; 90(6): 3856-3862, 2018 03 20.
Artigo em Inglês | MEDLINE | ID: mdl-29436814

RESUMO

Mass spectrometers are sensitive tools used to identify and quantify both small and large analytes using the mass-to-charge ratios ( m/ z) of ions generated by electrospray ionization (ESI) or other methods. Ionization typically generates protonated or deprotonated forms of the analytes or adducts with adventitious metal ions derived from the spray solvent. The formation of a variety of ionized forms of the analyte as well as the presence of cluster ions complicates the data and can have deleterious effects on the performance of the mass spectrometer, especially under high salt or buffer conditions. To address this, a method involving a dual-electrode nano-electrospray source has been implemented to rapidly and temporarily desalt the spray solution of interfering cationic and anionic species using electrophoretic transport from the spray tip. Peptides, proteins, and pharmaceutical drugs all showed improved results after the desalting process as measured by the quality of the mass spectra and the limits of detection achieved. Importantly ordinary phosphate buffers could be used to record protein mass spectra by nano-ESI.

5.
Anal Chem ; 89(13): 6969-6975, 2017 07 05.
Artigo em Inglês | MEDLINE | ID: mdl-28520396

RESUMO

Advances in chemical sampling using miniature mass spectrometer technology are used to monitor slow reactions at a frequency of ca. 180 h-1 (on the Mini 12) with no sample carryover and with inline derivatization in the case of poorly ionizing compounds. Moreover, we demonstrate high reproducibility with a relative error of less than 10% for major components. Monitoring is enabled using a continuous-flow nanoelectrospray (CF-nESI) probe contained in a custom-built 3D-printed rotary holder. The holder position is automatically set using a stepper motor controlled by a microcontroller. Reaction progress of up to six reactions, including hydrazone formation and Katritzky transamination, can be monitored simultaneously without carryover for several hours.

6.
Analyst ; 141(8): 2441-6, 2016 Apr 21.
Artigo em Inglês | MEDLINE | ID: mdl-26979554

RESUMO

Chiral analysis of constituents in solution-phase reaction mixtures can be performed by tandem mass spectrometry using the kinetic method to determine the enantiomeric excess (ee). Simply diluting an aliquot of a reaction mixture, adjusting the pH, and adding reagents necessary to form a chiral cluster ion allows chiral analysis. The product of a stereospecific N-selective alkylation reaction, 2-(3-(2-methoxyethoxy)-5-oxo-1,6-naphthyridin-6(5H)-yl)propanoic acid, was monitored for ee during the course of reaction, and it showed the expected inversion without ee erosion. Base-catalyzed racemization of the reaction product showed the expected decrease in ee as the reaction proceeded. The base-catalyzed racemization of ibuprofen was monitored on-line, providing near real-time data on ee.

7.
Anal Chem ; 87(6): 3300-7, 2015 Mar 17.
Artigo em Inglês | MEDLINE | ID: mdl-25664640

RESUMO

The chirality of substituents on an amino acid can significantly change its mode of binding to a metal ion, as shown here experimentally by traveling wave ion mobility spectrometry-mass spectrometry (TWIMS-MS) of different proline isomeric molecules complexed with alkali metal ions. Baseline separation of the cis- and trans- forms of both hydroxyproline and fluoroproline was achieved using TWIMS-MS via metal ion cationization (Li(+), Na(+), K(+), and Cs(+)). Density functional theory calculations indicate that differentiation of these diastereomers is a result of the stabilization of differing metal-complexed forms adopted by the diastereomers when cationized by an alkali metal cation, [M + X](+) where X = Li, Na, K, and Cs, versus the topologically similar structures of the protonated molecules, [M + H](+). Metal-cationized trans-proline variants exist in a linear salt-bridge form where the metal ion interacts with a deprotonated carboxylic acid and the proton is displaced onto the nitrogen atom of the pyrrolidine ring. In contrast, metal-cationized cis-proline variants adopt a compact structure where the carbonyl of the carboxylic acid, nitrogen atom, and if available, the hydroxyl and fluorine substituent solvate the metal ion. Experimentally, it was observed that the resolution between alkali metal-cationized cis- and trans-proline variants decreases as the size of the metal ion increases. Density functional theory demonstrates that this is due to the decreasing stability of the compact charge-solvated cis-proline structure with increased metal ion radius, likely a result of steric hindrance and/or weaker binding to the larger metal ion. Furthermore, the unique structures adopted by the alkali metal-cationized cis- and trans-proline variants results in these molecules having significantly different quantum mechanically calculated dipole moments, a factor that can be further exploited to improve the diastereomeric resolution when utilizing a drift gas with a higher polarizability constant.


Assuntos
Hidroxiprolina/química , Hidroxiprolina/isolamento & purificação , Espectrometria de Massas/métodos , Metais Alcalinos/química , Prolina/análogos & derivados , Modelos Moleculares , Conformação Molecular , Nitrogênio/química , Prolina/química , Prolina/isolamento & purificação , Prótons , Solventes/química , Estereoisomerismo
8.
J Am Soc Mass Spectrom ; 34(11): 2491-2497, 2023 Nov 01.
Artigo em Inglês | MEDLINE | ID: mdl-37823612

RESUMO

Oligonucleotide characterization is a rapidly advancing field in the biopharmaceutical industry. Understanding critical quality attributes, such as intact mass and impurities, requires a toolbox of analytical techniques, which commonly includes liquid chromatography-mass spectrometry (LC-MS). Oligonucleotide LC-MS analysis frequently requires sample run times upward of 15 min to achieve separation of multiple oligonucleotide species. Additionally, LC methods frequently employ mobile phase additives such as triethylamine and 1,1,1,3,3,3-hexafluoro-2-propanol that are not always desired for use in MS instrumentation. Here, microfluidic capillary electrophoresis mass spectrometry (CE-MS) via ZipChip technology was employed to enable rapid intact mass analysis of oligonucleotide single strands. Baseline separation of equal length oligonucleotides was achieved in less than 4 min. Additionally, the potential of the ZipChip platform for separation of oligonucleotide full-length products (FLPs) and their impurities was evaluated.


Assuntos
Microfluídica , Oligonucleotídeos , Oligonucleotídeos/química , Espectrometria de Massas/métodos , Cromatografia Líquida , Eletroforese Capilar/métodos
9.
Anal Chem ; 84(17): 7511-7, 2012 Sep 04.
Artigo em Inglês | MEDLINE | ID: mdl-22881839

RESUMO

The presence of many salts, such as sodium chloride, can adversely affect the performance of native electrospray ionization mass spectrometry for the analysis of proteins and protein complexes by reducing the overall molecular ion abundances and distributing signal for any given charge state into many cationized forms with various numbers of adducts attached. Several solution additives, such as ammonium bromide, ammonium iodide, and NaSbF(6), can significantly lower the extent of sodium ion adduction to the molecular ions of proteins and protein complexes. For ubiquitin, addition of 25 mM ammonium bromide or ammonium iodide into aqueous solutions also containing 1.0 mM NaCl results in a factor of 72 and 56 increase, respectively, in the relative abundances of the fully protonated molecular ions compared to when these additives are not present. The effectiveness of this method for reducing sodium ion adduction is related to the low proton affinity (PA) values of the anions. Anions with very low PA also have a propensity to adduct as an acid molecule, but these adducts can be readily dissociated from the molecular ions either by activation in the source or subsequently by collisional activation in the mass spectrometer. This method of reducing sodium ion adduction to proteins is simple and requires no experimental modifications, making it an attractive alternative to other methods for desalting proteins prior to mass spectrometry analysis.


Assuntos
Proteínas/análise , Espectrometria de Massas por Ionização por Electrospray , Brometos/química , Íons/química , Compostos de Amônio Quaternário/química , Cloreto de Sódio/química , Soluções/química , Ubiquitina/análise
10.
Anal Chem ; 83(6): 2210-4, 2011 Mar 15.
Artigo em Inglês | MEDLINE | ID: mdl-21338067

RESUMO

A solution additive has been discovered that can be used to measure the number of basic sites in a peptide or protein using electrospray ionization (ESI) mass spectrometry. Addition of millimolar amounts of perchloric acid (HClO(4)) to aqueous solutions that contain peptides or proteins results in the noncovalent adduction of HClO(4) molecules to the multiply charged ions formed by ESI. For 18 oligopeptides and proteins, ranging in molecular weight from 0.5 to 18.3 kDa, the sum of the number of protons plus maximum number of HClO(4) molecules adducted to the lower charge state ions is equal to the number of basic sites in the molecule. This method provides a rapid means of obtaining information about the composition of a peptide or protein and does not require high-resolution measurements or any instrumental or experimental modifications.


Assuntos
Peptídeos/química , Proteínas/química , Espectrometria de Massas por Ionização por Electrospray , Animais , Bovinos , Concentração de Íons de Hidrogênio , Peso Molecular , Percloratos/química
11.
J Am Soc Mass Spectrom ; 32(8): 1901-1909, 2021 Aug 04.
Artigo em Inglês | MEDLINE | ID: mdl-33390012

RESUMO

Aspartic acid (Asp) to isoaspartic acid (isoAsp) isomerization in therapeutic monoclonal antibodies (mAbs) and other biotherapeutics is a critical quality attribute (CQA) that requires careful control and monitoring during the drug discovery and production processes. The unwanted formation of isoAsp within biotherapeutics and resultant structural changes in the peptide backbone may negatively impact the efficacy, potency, and safety of the molecule or become immunogenic, especially if the isomerization occurs within the mAb complementarity determining region (CDR). Herein we describe a MALDI-TOF/TOF mass spectrometry method that affords unequivocal identification of the presence and the exact position of the isoAsp residue(s) in peptide standards ranging in size from a tripeptide to a docosapeptide (22 residues). In general, the peptide bond immediately N-terminal to the isoAsp residue is more susceptible to MALDI-TOF/TOF fragmentation than its unmodified counterpart. In some of the peptides evaluated in this study, fragmentation of the peptide bond C-terminal to the isoAsp residue (the aspartate effect) is also enhanced when compared to the control. Relative quantification by MALDI-TOF/TOF of this chemical modification is dependent upon a successful reversed-phase HPLC (rpHPLC) separation of the control and modified peptides. This method has also been validated on a therapeutic mAb that contains a well-documented isoAsp residue in the heavy chain CDR3 after forced degradation. Moreover, we also demonstrate that higher energy C-trap dissociation of only the singly charged species, and not the multiply charged form, of the isoAsp containing peptide, separated by rpHPLC, results in LC-MS/MS fragmentation that is highly consistent to that of MALDI-TOF/TOF.


Assuntos
Ácido Aspártico/análise , Ácido Aspártico/química , Peptídeos/química , Espectrometria de Massas por Ionização e Dessorção a Laser Assistida por Matriz/métodos , Anticorpos Monoclonais/análise , Anticorpos Monoclonais/química , Regiões Determinantes de Complementaridade/química , Ácido Isoaspártico/análise , Ácido Isoaspártico/química , Peptídeos/análise , Peptídeos/normas , Espectrometria de Massas em Tandem
12.
J Am Soc Mass Spectrom ; 32(8): 1952-1963, 2021 Aug 04.
Artigo em Inglês | MEDLINE | ID: mdl-33730487

RESUMO

The aspiration of the multi-attribute method (MAM) is to utilize a single mass spectrometry-based method that can measure multiple attributes simultaneously, thus enabling data-driven decisions more quickly and efficiently. However, challenges associated with identifying and quantitating critical quality attributes such as asparagine deamidation and isoaspartic acid using conventional ultrahigh-pressure liquid chromatography (UHPLC) coupled to mass spectrometry have necessitated long gradients to ensure sufficient separation for quantitation. Microfluidic chip-based capillary zone electrophoresis mass spectrometry (CZE-MS) shows potential to enable rapid charge-based separation of peptide mixtures, and this approach was evaluated using multipeptide mixtures of synthetic peptides as well as digested protein therapeutics. In these experiments, repeatability, linearity, and peak-to-peak resolution of several peptide families containing asparagine deamidation and/or isoaspartic acid were demonstrated. In addition, a comparison of peptide map results acquired with both UHPLC-MS and CZE-MS for two enzymatically digested biological therapeutics showed comparable sequence coverage and quantitation results between the two approaches. As MAM becomes increasingly utilized for analysis of biological therapeutics, MS instrument demand will rapidly increase, resulting in a bottleneck. A CZE-based separation shows potential to alleviate this bottleneck by drastically increasing MAM throughput while providing results comparable to those acquired using conventional UHPLC separations.


Assuntos
Eletroforese Capilar/instrumentação , Eletroforese Capilar/métodos , Espectrometria de Massas/métodos , Peptídeos/análise , Anticorpos Monoclonais/análise , Anticorpos Monoclonais/química , Asparagina/química , Produtos Biológicos/análise , Produtos Biológicos/química , Cromatografia Líquida de Alta Pressão/métodos , Interações Hidrofóbicas e Hidrofílicas , Imunoglobulina G/análise , Imunoglobulina G/química , Ácido Isoaspártico/química , Dispositivos Lab-On-A-Chip , Mapeamento de Peptídeos , Peptídeos/química , Peptídeos/isolamento & purificação , Reprodutibilidade dos Testes
13.
Anal Chem ; 82(4): 1179-82, 2010 Feb 15.
Artigo em Inglês | MEDLINE | ID: mdl-20092258

RESUMO

Accurate and rapid quantitation is advantageous to identify counterfeit and substandard pharmaceutical drugs. A standard-free electrospray ionization mass spectrometry method is used to directly determine the dosage in the prescription and over-the-counter drugs Tamiflu, Sudafed, and Dramamine. A tablet of each drug was dissolved in aqueous solution, filtered, and introduced into solutions containing a known concentration of l-tryptophan, l-phenylalanine, or prednisone as a clustering agent. The active ingredient(s) incorporates statistically into large clusters of the clustering agent where effects of differential ionization/detection are substantially reduced. From the abundances of large clusters, the dosages of the active ingredients in each of the tablets were determined to typically better than 20% accuracy even when the ionization/detection efficiency of the individual components differed by over 100x. Although this unorthodox method for quantitation is not as accurate as using conventional standards, it has the advantages that it is fast, it can be applied to mixtures where the identities of the analytes are unknown, and it can be used when suitable standards may not be readily available, such as schedule I or II controlled substances or new designer drugs that have not previously been identified.


Assuntos
Aminoácidos/química , Dimenidrinato/análise , Oseltamivir/análise , Pseudoefedrina/análise , Dimenidrinato/química , Oseltamivir/química , Pseudoefedrina/química , Soluções , Espectrometria de Massas por Ionização por Electrospray , Comprimidos
14.
Mol Pharm ; 7(5): 1466-77, 2010 Oct 04.
Artigo em Inglês | MEDLINE | ID: mdl-20701327

RESUMO

Dissolution testing is frequently used to determine the rate and extent at which a drug is released from a dosage form, and it plays many important roles throughout drug product development. However, the traditional dissolution approach often emphasizes its application in quality control testing and usually strives to obtain 100% drug release. As a result, dissolution methods are not necessarily biorelevant and meaningful application of traditional dissolution methods in the early phases of drug product development can be very limited. This article will describe the development of a biorelevant in vitro dissolution method using USP apparatus 4, biorelevant media, and real-time online UV analysis. Several case studies in the areas of formulation selection, lot-to-lot variability, and food effect will be presented to demonstrate the application of this method in early phase formulation development. This biorelevant dissolution method using USP apparatus 4 provides a valuable tool to predict certain aspects of the in vivo drug release. It can be used to facilitate the formulation development/selection for pharmacokinetic (PK) and clinical studies. It may also potentially be used to minimize the number of PK studies, and to aid in the design of more efficient PK and clinical studies.


Assuntos
Química Farmacêutica/métodos , Farmacocinética , Animais , Disponibilidade Biológica , Química Farmacêutica/instrumentação , Formas de Dosagem , Interações Alimento-Droga , Humanos , Concentração de Íons de Hidrogênio , Absorção Intestinal , Solubilidade
15.
J Phys Chem A ; 114(2): 854-60, 2010 Jan 21.
Artigo em Inglês | MEDLINE | ID: mdl-19950916

RESUMO

Structures of trivalent lanthanide metal cations La(3+), Ho(3+), and Eu(3+) with deprotonated Ala(n) (n = 2-5) or Leu-enk (Tyr-Gly-Gly-Phe-Leu) are investigated with infrared multiple photon dissociation (IRMPD) spectroscopy between 900 and 1850 cm(-1) and theory. In all of these complexes, a salt bridge is formed in which the metal cation coordinates to the carboxylate group of the peptide, resulting in a limited conformational space and many sharp IRMPD spectral bands. The IRMPD spectra clearly indicate that all carbonyl groups solvate the metal cation in each of the Ala(n) complexes. Due to strong vibrational coupling between the carbonyl groups, a sharp, high-energy amide I band due to in-phase stretching of all of the amide carbonyl groups bound to the metal cation is observed that is separated by approximately 50 cm(-1) from a strong, lower-energy amide I band. This extent of carbonyl coupling, which is sometimes observed in condensed-phase peptide and protein IR spectroscopy, has not been reported in IRMPD spectroscopy studies of other cationized peptide complexes. Intense bands due to carbonyl groups not associated with the metal cation are observed for Leu-enk complexes, indicating that a side chain group, such as the Tyr or Phe aromatic ring, prevents complete carbonyl coordination of the metal cation. Substitution of smaller lanthanide cations for La(3+) in these peptide complexes results only in minor structural changes consistent with the change in metal cation size. These are the first IRMPD spectra reported for lanthanide metal cationized peptides, and comparison to previously reported protonated and alkali metal or alkaline earth metal cationized peptide complexes reveals many trends consistent with the higher charge state of the lanthanide cations.


Assuntos
Cátions/química , Metais/química , Oligopeptídeos/química , Algoritmos , Amidas/química , Ácidos Carboxílicos/química , Encefalina Leucina/química , Európio/química , Hólmio/química , Lantânio/química , Modelos Moleculares , Simulação de Dinâmica Molecular , Peptídeos/química , Conformação Proteica , Espectrofotometria Infravermelho/métodos
16.
Anal Chem ; 81(10): 3965-72, 2009 May 15.
Artigo em Inglês | MEDLINE | ID: mdl-19354265

RESUMO

In electrospray ionization mass spectrometry, ion abundances depend on a number of different factors, including analyte surface activity, competition between analytes for charge, analyte concentration, as well as instrumental factors, including mass-dependent ion transmission and detection. Here, a novel method for obtaining quantitative information about solution-phase concentrations of peptide mixtures is described and demonstrated for five different peptide mixtures with relative concentrations ranging from 0.05% to 50%. In this method, the abundances of large clusters containing anywhere from 0 to 13 impurity molecules are measured and directly related to the relative solution-phase concentration of the peptides. For clusters containing approximately 15 or more peptides, the composition of the clusters approaches the statistical value indicating that these clusters are formed nonspecifically and that any differences in ion detection or ionization efficiency are negligible at these large cluster sizes. This method is accurate to within approximately 20% or better, even when the relative ion intensities of the protonated monomers can differ by over an order of magnitude compared to their solution-phase concentrations. Although less accurate than other quantitation methods that employ internal standards, this method does have the key advantages of speed, simplicity, and the ability to quantitate components in solution even when the identities of the components are unknown.


Assuntos
Peptídeos/análise , Espectrometria de Massas por Ionização por Electrospray/métodos , Bradicinina/análise , Bradicinina/química , Encefalina Leucina/análise , Encefalina Leucina/química , Peptídeos/química
17.
Anal Chem ; 81(20): 8434-40, 2009 Oct 15.
Artigo em Inglês | MEDLINE | ID: mdl-19754104

RESUMO

Ion abundances in electrospray ionization mass spectra depend on many factors, including molecular hydrophobicity, basicity, solution composition, and instrumental parameters. A recently introduced method that uses nonspecific cluster ion abundances to obtain solution-phase molar fractions of analytes directly from ESI mass spectra without using standards was evaluated using solutions containing 0.03-24% L-threonine, D-threonine, L-leucine, L-lysine, L-glutamic acid, or diglycine with L-serine as a major component. Because of the propensity of serine clusters to exhibit "magic" numbers, which can be chirally selective, these experiments provide a rigorous test of this standard-free cluster quantitation method, which requires that clusters form statistically from analytes in solution. For each of these solutions, the compositions of clusters containing > or = 32 molecules reflect the solution molar fractions of each component. From the abundances of these larger clusters, the solution molar fraction can be determined to better than 10% accuracy over nearly 3 orders of magnitude in concentration. In contrast, the ionization/detection efficiency of the individual amino acids differs by as much as a factor of 460 in these experiments. The protonated octamer incorporates some molecules statistically but efficiently excludes other molecules that have significantly different properties or chirality. This standard-free quantitation method may be most advantageous for rapidly characterizing mixtures, such as products of chemical synthesis, which contain unknown products or molecules for which suitable standards are not readily available.


Assuntos
Espectrometria de Massas por Ionização por Electrospray/métodos , Aminoácidos/análise , Aminoácidos/química , Padrões de Referência , Espectrometria de Massas por Ionização por Electrospray/normas
18.
J Am Soc Mass Spectrom ; 24(2): 193-201, 2013 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-23283726

RESUMO

With electrospray ionization from aqueous solutions, trivalent metal ions readily adduct to small peptides resulting in formation of predominantly (peptide + M(T) - H)(2+), where M(T) = La, Tm, Lu, Sm, Ho, Yb, Pm, Tb, or Eu, for peptides with molecular weights below ~1000 Da, and predominantly (peptide + M(T))(3+) for larger peptides. ECD of (peptide + M(T) - H)(2+) results in extensive fragmentation from which nearly complete sequence information can be obtained, even for peptides for which only singly protonated ions are formed in the absence of the metal ions. ECD of these doubly charged complexes containing M(T) results in significantly higher electron capture efficiency and sequence coverage than peptide-divalent metal ion complexes that have the same net charge. Formation of salt-bridge structures in which the metal ion coordinates to a carboxylate group are favored even for (peptide + M(T))(3+). ECD of these latter complexes for large peptides results in electron capture by the protonation site located remotely from the metal ion and predominantly c/z fragments for all metals, except Eu(3+), which undergoes a one electron reduction and only loss of small neutral molecules and b/y fragments are formed. These results indicate that solvation of the metal ion in these complexes is extensive, which results in the electrochemical properties of these metal ions being similar in both the peptide environment and in bulk water.


Assuntos
Complexos de Coordenação/química , Elementos da Série dos Lantanídeos/química , Peptídeos/química , Espectrometria de Massas por Ionização por Electrospray/métodos , Cátions/química , Elétrons
19.
J Am Soc Mass Spectrom ; 24(11): 1654-62, 2013 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-23733259

RESUMO

Changes in protein ion conformation as a result of nonspecific adduction of metal ions to the protein during electrospray ionization (ESI) from aqueous solutions were investigated using traveling wave ion mobility spectrometry (TWIMS). For all proteins examined, protein cations (and in most cases anions) with nonspecific metal ion adducts are more compact than the fully protonated (or deprotonated) ions with the same charge state. Compaction of protein cations upon nonspecific metal ion binding is most significant for intermediate charge state ions, and there is a greater reduction in collisional cross section with increasing number of metal ion adducts and increasing ion valency, consistent with an electrostatic interaction between the ions and the protein. Protein cations with the greatest number of adducted metal ions are no more compact than the lowest protonated ions formed from aqueous solutions. These results show that smaller collisional cross sections for metal-attached protein ions are not a good indicator of a specific metal-protein interaction in solution because nonspecific metal ion adduction also results in smaller gaseous protein cation cross sections. In contrast, the collisional cross section of α-lactalbumin, which specifically binds one Ca(2+), is larger for the holo-form compared with the apo-form, in agreement with solution-phase measurements. Because compaction of protein cations occurs when metal ion adduction is nonspecific, elongation of a protein cation may be a more reliable indicator that a specific metal ion-protein interaction occurs in solution.


Assuntos
Íons/química , Conformação Proteica , Proteínas/química , Cátions Bivalentes/química , Citocromos c/química , Gases/química , Lactalbumina/química , Metais/química , Soluções , Espectrometria de Massas por Ionização por Electrospray/métodos , Ubiquitina/química
20.
J Am Soc Mass Spectrom ; 23(11): 1885-95, 2012 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-22948901

RESUMO

Addition of 1.0 mM LaCl(3) to aqueous ammonium acetate solutions containing proteins in their folded native forms can result in a significant increase in the molecular ion charging obtained with electrospray ionization as a result of cation adduction. In combination with m-nitrobenzyl alcohol, molecular ion charge states that are greater than the number of basic sites in the protein can be produced from these native solutions, even for lysozyme, which is conformationally constrained by four intramolecular disulfide bonds. Circular dichroism spectroscopy indicates that the conformation of ubiquitin is not measurably affected with up to 1.0 M LaCl(3), but ion mobility data indicate that the high charge states that are formed when 1.0 mM LaCl(3) is present are more unfolded than the low charge states formed without this reagent. These and other results indicate that the increased charging is a result of La(3+) preferentially adducting onto compact or more native-like conformers during ESI and the gas-phase ions subsequently unfolding as a result of increased Coulomb repulsion. Electron capture dissociation of these high charge-state ions formed from these native solutions results in comparable sequence coverage to that obtained for ions formed from denaturing solutions without supercharging reagents, making this method a potentially powerful tool for obtaining structural information in native mass spectrometry.


Assuntos
Metais/química , Espectrometria de Massas por Ionização por Electrospray/métodos , Animais , Cátions/química , Bovinos , Galinhas , Dicroísmo Circular , Lantânio/química , Proteínas/análise , Proteínas/química
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA