Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Intervalo de ano de publicação
1.
J Clin Microbiol ; 61(2): e0161722, 2023 02 22.
Artigo em Inglês | MEDLINE | ID: mdl-36719243

RESUMO

In 2022, the Clinical and Laboratory Standards Institute (CLSI) updated piperacillin-tazobactam (TZP) breakpoints for Enterobacterales, based on substantial data suggesting that historical breakpoints did not predict treatment outcomes for TZP. The U.S. Food and Drug Administration (FDA) has not yet adopted these breakpoints, meaning commercial manufacturers of antimicrobial susceptibility testing devices cannot obtain FDA clearance for the revised breakpoints. We evaluated the Phoenix (BD, Sparks, MD), MicroScan (Beckman Coulter, Sacramento, CA), and Vitek2 (bioMérieux, Durham, NC) TZP MICs compared to reference broth microdilution for a collection of 284 Enterobacterales isolates. Phoenix (n = 167 isolates) demonstrated 84.4% categorical agreement (CA), with 4.2% very major errors (VMEs) and 1.8% major errors (MEs) by CLSI breakpoints. In contrast, CA was 85.0% with 4.3% VMEs and 0.8% MEs for the Phoenix with FDA breakpoints. MicroScan (n = 55 isolates) demonstrated 80.0% CA, 36.4% VMEs, and 4.8% MEs by CLSI breakpoints and 81.8% CA, 44.4% VMEs, and 0.0% MEs by FDA breakpoints. Vitek2 (n = 62 isolates) demonstrated 95.2% CA, 6.3% VMEs, and 0.0% MEs by CLSI and 96.8% CA, 0.0% VMEs, and 2.2% MEs by FDA breakpoints. Overall, the performance of the test systems was not substantially different using CLSI breakpoints off-label than using on-label FDA breakpoints. However, limitations were noted with higher-than-desired VME rates (all three systems) and lower-than-desired CA (MicroScan and Phoenix). Laboratories should consider adoption of the revised CLSI breakpoints with automated test systems but be aware that some performance challenges exist for testing TZP on automated systems, regardless of breakpoints applied.


Assuntos
Antibacterianos , Humanos , Testes de Sensibilidade Microbiana , Combinação Piperacilina e Tazobactam
2.
J Clin Microbiol ; 61(11): e0035723, 2023 11 21.
Artigo em Inglês | MEDLINE | ID: mdl-37877730

RESUMO

The bioMérieux BIOFIRE Joint Infection (JI) Panel is a multiplex in vitro diagnostic test for the simultaneous and rapid (~1 h) detection of 39 potential pathogens and antimicrobial resistance (AMR) genes directly from synovial fluid (SF) samples. Thirty-one species or groups of microorganisms are included in the kit, as well as several AMR genes. This study, performed to evaluate the BIOFIRE JI Panel for regulatory clearance, provides data from a multicenter evaluation of 1,544 prospectively collected residual SF samples with performance compared to standard-of-care (SOC) culture for organisms or polymerase chain reaction (PCR) and sequencing for AMR genes. The BIOFIRE JI Panel demonstrated a sensitivity of 90.9% or greater for all but six organisms and a positive percent agreement (PPA) of 100% for all AMR genes. The BIOFIRE JI Panel demonstrated a specificity of 98.5% or greater for detection of all organisms and a negative percent agreement (NPA) of 95.7% or greater for all AMR genes. The BIOFIRE JI Panel provides an improvement over SOC culture, with a substantially shorter time to result for both organisms and AMR genes with excellent sensitivity/PPA and specificity/NPA, and is anticipated to provide timely and actionable diagnostic information for joint infections in a variety of clinical scenarios.


Assuntos
Anti-Infecciosos , Artrite Infecciosa , Humanos , Saccharomyces cerevisiae/genética , Líquido Sinovial/microbiologia , Reação em Cadeia da Polimerase Multiplex , Bactérias/genética , Artrite Infecciosa/diagnóstico
3.
J Clin Microbiol ; 60(8): e0012222, 2022 08 17.
Artigo em Inglês | MEDLINE | ID: mdl-35852363

RESUMO

Bloodstream infection poses a significant medical emergency that necessitates timely administration of appropriate antibiotics. Standard laboratory workup for antimicrobial susceptibility testing (AST) involves subculture of organisms from positive blood bottles followed by testing using broth microdilution; however, this process can take several days. The Accelerate Pheno Blood Culture panel (Pheno) provides rapid phenotypic testing of selected Gram-negative organisms directly from positive blood cultures. This has the potential to shorten the AST process to several hours and impact time to antimicrobial optimization and subsequent clinical outcomes; however, these metrics have not been assessed in pediatric populations. We retrospectively compared two patient cohorts with blood cultures positive for on-panel Gram-negative organisms: 82 cases tested by conventional AST methods, and 80 cases postintervention at our pediatric hospital. Susceptibility testing from the Pheno yielded 91.5% categorical agreement with a broth microdilution-based reference method with 7.4% minor error, 1.1% major error, and 0.1% very major error rates. The median time from blood culture positivity to AST decreased from 20.0 h to 9.7 h (P < 0.001), leading to an overall decrease in time from blood culture positivity to change in therapy from 36.0 h to 25.0 h (P < 0.001). There was no observed change in length of stay or 30-day mortality. Median duration on meropenem decreased from 64.8 h to 31.6 h (P = 0.04). We conclude the Pheno had accurate performance and that implementation allowed for faster AST reporting, improved time to optimal therapy, and decreased duration on meropenem in children.


Assuntos
Anti-Infecciosos , Bacteriemia , Infecções por Bactérias Gram-Negativas , Antibacterianos/farmacologia , Antibacterianos/uso terapêutico , Anti-Infecciosos/uso terapêutico , Bacteriemia/diagnóstico , Bacteriemia/tratamento farmacológico , Criança , Bactérias Gram-Negativas , Infecções por Bactérias Gram-Negativas/tratamento farmacológico , Hospitais Pediátricos , Humanos , Meropeném , Testes de Sensibilidade Microbiana , Estudos Retrospectivos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA