Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 64
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
Q J Nucl Med Mol Imaging ; 67(1): 4-13, 2023 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-36633588

RESUMO

The use of alpha emitting radiotherapeutics is increasing, with further growth expected due to a number of clinical trials currently running involving new alpha emitters. However, literature concerning radiation safety aspects of alpha emitting radionuclides is limited and most of the available literature concerns 223Ra. In general, the occupational exposure from alpha emitting radionuclides is expected to be low, as are doses to the public from external exposure. However, care must be taken to avoid skin contamination, inhalation, and ingestion. Not all alpha emitting radionuclides are identical, they often have very different associated decay chains and emissions. The decay chains and the manufacturing process should be carefully examined to identify any long-lived progeny or impurities. These may have an impact on the radiation safety processes required to limit occupational exposure and for waste management. Doses to the public must also be assessed, either arising directly from exposure to patients treated with radiotherapeutics, or via waste streams. Risk assessments should be in place when starting a new service covering all aspects of the preparation and administration, as well as any foreseeable incidents such as skin contamination or patient death, and the appropriate steps to take in these instances. It is imperative that with the increase in the use of alpha emitting radiotherapeutics more literature is published on radiation safety aspects, especially for new alpha emitting radiotherapeutics which often have very different characteristics than the currently established ones.


Assuntos
Proteção Radiológica , Humanos , Radioisótopos/efeitos adversos , Medição de Risco , Partículas alfa/efeitos adversos , Doses de Radiação
2.
Eur J Nucl Med Mol Imaging ; 49(9): 3247-3256, 2022 07.
Artigo em Inglês | MEDLINE | ID: mdl-35320386

RESUMO

PURPOSE: Concern is growing about long-term side effects of differentiated thyroid cancer treatment, most notably radioactive iodine (RAI) therapy. However, published studies on the subject have had heterogeneous cohorts and conflicting results. This review seeks to provide an updated evaluation of published evidence, and to elucidate the risk of second primary malignancies (SPMs), especially secondary hematologic malignancies (SHMs), attributable to RAI therapy. METHODS: An extensive literature search was performed in Ovid MEDLINE, Ovid MEDLINE and In-Process & Other Non-Indexed Citations, Ovid MEDLINE Epub Ahead of Print, Cochrane Central Register of Controlled Trials (CENTRAL) and PubMed. Studies regarding RAI-induced SPMs or a dose-response relationship between RAI therapy and SPMs were identified, 10 of which were eligible for the analysis. We evaluated risk of bias in each study and judged quality of evidence (QOE) across all studies using the Grading of Recommendations, Assessment, Development and Evaluations approach. RESULTS: For the outcome "SPM", the relative effect (relative risk, hazard ratio, or odds ratio) of RAI vs. no RAI ranged from 1.14 to 1.84 across studies, but most results were not statistically significant. For the outcome "SHM", reported relative effects ranged from 1.30 to 2.50, with 2/3 of the studies presenting statistically significant results. In 7/8 of the studies, increased risk for SPM was shown with increasing cumulative RAI activity. QOE was "very low" regarding SPM after RAI and regarding a dose-response relationship, and "low" for SHM after RAI. CONCLUSION: Based on low quality evidence, an excess risk for the development of SPM cannot be excluded but is expected to be small.


Assuntos
Adenocarcinoma , Neoplasias Induzidas por Radiação , Segunda Neoplasia Primária , Neoplasias da Glândula Tireoide , Adenocarcinoma/complicações , Humanos , Radioisótopos do Iodo/efeitos adversos , Neoplasias Induzidas por Radiação/etiologia , Segunda Neoplasia Primária/etiologia , Risco , Neoplasias da Glândula Tireoide/radioterapia
3.
J Radiol Prot ; 41(4)2021 Nov 11.
Artigo em Inglês | MEDLINE | ID: mdl-34261047

RESUMO

Biokinetic models developed for healthy humans are not appropriate to describe biokinetics in thyroid cancer patients following thyroidectomy. The aim of this study was to adjust the population model for iodine proposed by the International Commission on Radiological Protection (ICRP) for the use in these patients. Rate constants of the ICRP publication 128 model for iodine were adjusted using the population modelling software package Monolix to describe activity retention in whole-body, thyroid, blood and protein-bound iodine observed in 23 patients. The new set of rate constants was compared to the four uptake scenarios proposed in ICRP publication 128. Flow from the inorganic iodide in blood compartment into the first thyroid compartment decreases to 0.15 d-1compared to a value of 7.27 d-1for the ICRP publication 128 model with a medium uptake. The transfer from first to second thyroid compartments and the outflow from the second thyroid compartment increases. An increased turnover rate of extrathyroidal organic iodine is observed. The rate constant from inorganic iodide in blood to kidney was also adjusted. Overall a good agreement was found between the adjusted model and the activity retention in thyroid cancer patients. The adjustment of population pharmacokinetic models to describe the biokinetic properties of specific patient populations for therapeutic radiopharmaceuticals is essential to capture the changes in biokinetics. The proposed set of rate constants for the established ICRP publication 128 model can be used to more accurately assess radiation protection requirements for the treatment of thyroid cancer patients using radioiodine.


Assuntos
Iodo , Proteção Radiológica , Neoplasias da Glândula Tireoide , Humanos , Iodetos , Radioisótopos do Iodo/uso terapêutico , Neoplasias da Glândula Tireoide/cirurgia , Tireoidectomia
4.
Q J Nucl Med Mol Imaging ; 63(3): 271-277, 2019 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-31315346

RESUMO

The field of molecular radiotherapy is expanding rapidly, with the advent of many new radiotherapeutics for the treatment of common as well as for rare cancers. Treatment outcome is dependent on the absorbed doses delivered to target volumes and to healthy organs-at-risk, which are shown to vary widely from fixed administrations of activity. There have been significant developments in quantitative imaging and internal dosimetry in recent years, although clinical implementation of these methods has been slow in comparison with external beam radiotherapy, partly due to there being relatively few patients treated at single centers. Multicenter clinical trials are therefore essential to acquire the data required to ensure best practice and to develop the personalized treatment planning that this area is well suited to, due to the unrivalled opportunity to image the therapeutic drug in vivo. Initial preparation for such trials requires a significant effort in terms of resources and trial design. Imaging systems in participating centers must be characterized and set up for quantitative imaging to allow for collation of data. Data transfer for centralized processing is usually necessary but is hindered in some cases by data protection regulations and local logistics. Recent multicenter clinical trials involving radioiodine therapy have begun to establish the procedures necessary for quantitative SPECT imaging in a multicenter setting using standard and anthropomorphic phantoms. The establishment of national and international multicenter imaging and dosimetry networks will provide frameworks to develop and harmonize best practice with existing therapeutic procedures and to ensure rapid and optimized clinical implementation of new radiotherapeutics across all centers of excellence that offer molecular radiotherapy. This will promote networks and collaborations that can provide a sound basis for further developments and will ensure that nuclear medicine maintains a key role in future developments.


Assuntos
Ensaios Clínicos como Assunto/métodos , Radioisótopos do Iodo/uso terapêutico , Estudos Multicêntricos como Assunto/métodos , Neoplasias da Glândula Tireoide/patologia , Neoplasias da Glândula Tireoide/radioterapia , Humanos , Radiometria
5.
Eur J Nucl Med Mol Imaging ; 45(13): 2456-2474, 2018 12.
Artigo em Inglês | MEDLINE | ID: mdl-30218316

RESUMO

A framework is proposed for modelling the uncertainty in the measurement processes constituting the dosimetry chain that are involved in internal absorbed dose calculations. The starting point is the basic model for absorbed dose in a site of interest as the product of the cumulated activity and a dose factor. In turn, the cumulated activity is given by the area under a time-activity curve derived from a time sequence of activity values. Each activity value is obtained in terms of a count rate, a calibration factor and a recovery coefficient (a correction for partial volume effects). The method to determine the recovery coefficient and the dose factor, both of which are dependent on the size of the volume of interest (VOI), are described. Consideration is given to propagating estimates of the quantities concerned and their associated uncertainties through the dosimetry chain to obtain an estimate of mean absorbed dose in the VOI and its associated uncertainty. This approach is demonstrated in a clinical example.


Assuntos
Neoplasias/radioterapia , Guias de Prática Clínica como Assunto , Planejamento da Radioterapia Assistida por Computador/métodos , Algoritmos , Humanos , Compostos Radiofarmacêuticos/administração & dosagem , Compostos Radiofarmacêuticos/uso terapêutico , Dosagem Radioterapêutica , Incerteza , Radioisótopos de Ítrio/administração & dosagem , Radioisótopos de Ítrio/uso terapêutico
6.
Eur J Nucl Med Mol Imaging ; 44(11): 1832-1844, 2017 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-28612079

RESUMO

PURPOSE: The aims of this study were to calculate bone lesion absorbed doses resulting from a weight-based administration of 223Ra-dichloride, to assess the relationship between those doses and corresponding 18F-fluoride uptake and to assess the potential of quantitative 18F-fluoride imaging to predict response to treatment. METHODS: Five patients received two intravenous injections of 223Ra-dichloride, 6 weeks apart, at 110 kBq/kg whole-body weight. The biodistribution of 223Ra in metastatic lesions as a function of time after administration as well as associated lesion dosimetry were determined from serial 223Ra scans. PET/CT imaging using 18F-fluoride was performed prior to the first treatment (baseline), and at week 6 immediately before the second treatment and at week 12 after baseline. RESULTS: Absorbed doses to metastatic bone lesions ranged from 0.6 Gy to 44.1 Gy. For individual patients, there was an average factor difference of 5.3 (range 2.5-11.0) between the maximum and minimum lesion dose. A relationship between lesion-absorbed doses and serial changes in 18F-fluoride uptake was demonstrated (r2 = 0.52). A log-linear relationship was demonstrated (r2 = 0.77) between baseline measurements of 18F-fluoride uptake prior to 223Ra-dichloride therapy and changes in uptake 12 weeks after the first cycle of therapy. Correlations were also observed between both 223Ra and 18F-fluoride uptake in lesions (r = 0.75) as well as between 223Ra absorbed dose and 18F-fluoride uptake (r = 0.96). CONCLUSIONS: There is both inter-patient and intra-patient heterogeneity of absorbed dose estimates to metastatic lesions. A relationship between 223Ra lesion absorbed dose and subsequent lesion response was observed. Analysis of this small group of patients suggests that baseline uptake of 18F-fluoride in bone metastases is significantly correlated with corresponding uptake of 223Ra, the associated 223Ra absorbed dose and subsequent lesion response to treatment.


Assuntos
Radioisótopos de Flúor/farmacocinética , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada/métodos , Neoplasias de Próstata Resistentes à Castração/diagnóstico por imagem , Compostos Radiofarmacêuticos/farmacocinética , Rádio (Elemento)/farmacocinética , Idoso , Ensaios Clínicos Fase I como Assunto , Humanos , Masculino , Pessoa de Meia-Idade , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada/normas , Neoplasias de Próstata Resistentes à Castração/radioterapia , Radioisótopos/administração & dosagem , Radioisótopos/uso terapêutico , Compostos Radiofarmacêuticos/administração & dosagem , Compostos Radiofarmacêuticos/uso terapêutico , Rádio (Elemento)/administração & dosagem , Rádio (Elemento)/uso terapêutico
7.
Eur J Nucl Med Mol Imaging ; 44(4): 620-629, 2017 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-27770145

RESUMO

PURPOSE: To investigate the role of patient-specific dosimetry as a predictive marker of survival and as a potential tool for individualised molecular radiotherapy treatment planning of bone metastases from castration-resistant prostate cancer, and to assess whether higher administered levels of activity are associated with a survival benefit. METHODS: Clinical data from 57 patients who received 2.5-5.1 GBq of 186Re-HEDP as part of NIH-funded phase I/II clinical trials were analysed. Whole-body and SPECT-based absorbed doses to the whole body and bone lesions were calculated for 22 patients receiving 5 GBq. The patient mean absorbed dose was defined as the mean of all bone lesion-absorbed doses in any given patient. Kaplan-Meier curves, log-rank tests, Cox's proportional hazards model and Pearson's correlation coefficients were used for overall survival (OS) and correlation analyses. RESULTS: A statistically significantly longer OS was associated with administered activities above 3.5 GBq in the 57 patients (20.1 vs 7.1 months, hazard ratio: 0.39, 95 % CI: 0.10-0.58, P = 0.002). A total of 379 bone lesions were identified in 22 patients. The mean of the patient mean absorbed dose was 19 (±6) Gy and the mean of the whole-body absorbed dose was 0.33 (±0.11) Gy for the 22 patients. The patient mean absorbed dose (r = 0.65, P = 0.001) and the whole-body absorbed dose (r = 0.63, P = 0.002) showed a positive correlation with disease volume. Significant differences in OS were observed for the univariate group analyses according to disease volume as measured from SPECT imaging of 186Re-HEDP (P = 0.03) and patient mean absorbed dose (P = 0.01), whilst only the disease volume remained significant in a multivariable analysis (P = 0.004). CONCLUSION: This study demonstrated that higher administered activities led to prolonged survival and that for a fixed administered activity, the whole-body and patient mean absorbed doses correlated with the extent of disease, which, in turn, correlated with survival. This study shows the importance of patient stratification to establish absorbed dose-response correlations and indicates the potential to individualise treatment of bone metastases with radiopharmaceuticals according to patient-specific imaging and dosimetry.


Assuntos
Ácido Etidrônico/administração & dosagem , Compostos Organometálicos/administração & dosagem , Neoplasias de Próstata Resistentes à Castração/radioterapia , Doses de Radiação , Compostos Radiofarmacêuticos/administração & dosagem , Planejamento da Radioterapia Assistida por Computador , Neoplasias Ósseas/diagnóstico por imagem , Neoplasias Ósseas/secundário , Ensaios Clínicos Fase I como Assunto , Ensaios Clínicos Fase II como Assunto , Ácido Etidrônico/uso terapêutico , Humanos , Masculino , Compostos Organometálicos/uso terapêutico , Neoplasias de Próstata Resistentes à Castração/diagnóstico por imagem , Neoplasias de Próstata Resistentes à Castração/patologia , Compostos Radiofarmacêuticos/uso terapêutico , Dosagem Radioterapêutica , Análise de Sobrevida , Tomografia Computadorizada de Emissão de Fóton Único
8.
Eur J Nucl Med Mol Imaging ; 40(10): 1532-41, 2013 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-23740370

RESUMO

PURPOSE: (32)P-chromic phosphate colloid treatments of astrocytoma and craniopharyngioma cystic brain tumours in paediatric patients are conventionally based on a sphere model under the assumption of uniform uptake. The aims of this study were to determine the distribution of the absorbed dose delivered by (32)P on a patient-specific basis and to evaluate the accuracy with which this can be predicted from a pretherapy administration of (99m)Tc-Sn colloid. METHODS: Three patients were treated with (32)P-chromic phosphate colloid following (99m)Tc-Sn colloid administrations. Convolution dosimetry was performed using pretherapy and posttherapy sequential SPECT imaging, and verified with EGSnrc Monte Carlo radiation transport simulations. Mean absorbed doses to the cyst wall and dose-volume histograms were also calculated and compared with those obtained by the sphere model approach. RESULTS: Highly nonuniform uptake distributions of both the (99m)Tc and (32)P colloids were observed and characterized by dose-volume histograms to the cyst wall. Mean absorbed doses delivered to the cyst wall, obtained with the convolution method, were on average 21 % (SD 18 %) and 50 % (SD 30 %) lower than those predicted by the (99m)Tc distribution and the uniform assumption of the sphere model, respectively. CONCLUSION: Absorbed doses delivered to the cyst wall by (32)P are more accurately predicted from image-based patient-specific convolution dosimetry than from simple sphere models. These results indicate the necessity to perform personalized treatment planning and verification for intracavitary irradiation of cystic brain tumours treated with radiocolloids. Patient-specific dosimetry can be used to guide the frequency and levels of repeated administrations and would facilitate data collection and comparison to support the multicentre trials necessary to progress this therapy.


Assuntos
Astrocitoma/radioterapia , Neoplasias Encefálicas/radioterapia , Compostos de Cromo/farmacocinética , Craniofaringioma/radioterapia , Fosfatos/farmacocinética , Neoplasias Hipofisárias/radioterapia , Radiometria , Compostos Radiofarmacêuticos/farmacocinética , Astrocitoma/diagnóstico por imagem , Neoplasias Encefálicas/diagnóstico por imagem , Criança , Compostos de Cromo/uso terapêutico , Coloides/farmacocinética , Coloides/uso terapêutico , Craniofaringioma/diagnóstico por imagem , Cistos/diagnóstico por imagem , Cistos/radioterapia , Relação Dose-Resposta a Droga , Feminino , Humanos , Imageamento por Ressonância Magnética , Masculino , Modelos Biológicos , Fosfatos/uso terapêutico , Neoplasias Hipofisárias/diagnóstico por imagem , Compostos de Tecnécio/farmacocinética , Compostos de Tecnécio/uso terapêutico , Compostos de Estanho/farmacocinética , Compostos de Estanho/uso terapêutico , Tomografia Computadorizada de Emissão de Fóton Único
10.
J Nucl Med ; 64(7): 1125-1130, 2023 07.
Artigo em Inglês | MEDLINE | ID: mdl-37116914

RESUMO

Radioactive iodine is well established as a successful treatment for differentiated thyroid cancer (DTC), although around 15% of patients have local recurrence or develop distant metastases and may become refractory to radioactive iodine (RAI). A personalized approach to treatment, based on the absorbed radiation doses delivered and using treatments to enhance RAI uptake, has not yet been developed. Methods: We performed a multicenter clinical trial to investigate the role of selumetinib, which modulates the expression of the sodium iodide symporter, and hence iodine uptake, in the treatment of RAI-refractory DTC. The iodine uptake before and after selumetinib was quantified to assess the effect of selumetinib. The range of absorbed doses delivered to metastatic disease was calculated from pre- and posttherapy imaging, and the predictive accuracy of a theranostic approach to enable personalized treatment planning was investigated. Results: Significant inter- and intrapatient variability was observed with respect to the uptake of RAI and the effect of selumetinib. The absorbed doses delivered to metastatic lesions ranged from less than 1 Gy to 1,170 Gy. A strong positive correlation was found between the absorbed doses predicted from pretherapy imaging and those measured after therapy (r = 0.93, P < 0.001). Conclusion: The variation in outcomes from RAI therapy of DTC may be explained, among other factors, by the range of absorbed doses delivered. The ability to assess the effect of treatments that modulate RAI uptake, and to estimate the absorbed doses at therapy, introduces the potential for patient stratification using a theranostic approach. Patient-specific absorbed dose planning might be the key to more successful treatment of advanced DTC.


Assuntos
Neoplasias da Glândula Tireoide , Humanos , Neoplasias da Glândula Tireoide/diagnóstico por imagem , Neoplasias da Glândula Tireoide/radioterapia , Neoplasias da Glândula Tireoide/tratamento farmacológico , Radioisótopos do Iodo/uso terapêutico , Radiometria , Diagnóstico por Imagem
11.
J Nucl Med ; 63(3): 485-492, 2022 03.
Artigo em Inglês | MEDLINE | ID: mdl-34353873

RESUMO

This paper presents standardized methods for performing dose calculations for radiopharmaceuticals. Various steps in the process are outlined, with some specific examples given. Special models for calculating time-activity integrals (urinary bladder, intestines) are also reviewed. This article can be used as a template for designing and executing kinetic studies for calculating radiation dose estimates from animal or human data.


Assuntos
Análise de Dados , Compostos Radiofarmacêuticos , Animais , Cinética , Doses de Radiação , Radiometria/métodos
12.
J Nucl Med ; 63(2): 316-322, 2022 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-34353875

RESUMO

This paper presents standardized methods for collecting data to be used in performing dose calculations for radiopharmaceuticals. Various steps in the process are outlined, with some specific examples given. This document can be used as a template for designing and executing kinetic studies for calculating radiation dose estimates, from animal or human data.


Assuntos
Radiometria , Compostos Radiofarmacêuticos , Animais , Cinética , Doses de Radiação , Radiometria/métodos
13.
EJNMMI Phys ; 9(1): 86, 2022 Dec 13.
Artigo em Inglês | MEDLINE | ID: mdl-36512147

RESUMO

BACKGROUND: Accurate quantification of radioactivity in a source of interest relies on accurate registration between SPECT and anatomical images, and appropriate correction of partial volume effects (PVEs). For small volumes, exact registration between the two imaging modalities and recovery factors used to correct for PVE are unreliable. There is currently no guidance relating to quantification or the associated uncertainty estimation for small volumes. MATERIAL AND METHODS: A method for quantification of small sources of interest is proposed, which uses multiple oversized volumes of interest. The method was applied to three Na[131I]I activity distributions where a Na[131I]I capsule was situated within a cylindrical phantom containing either zero background, uniform background or non-uniform background and to a scenario with small lesions placed in an anthropomorphic phantom. The Na[131I]I capsule and lesions were quantified using the proposed method and compared with measurements made using two alternative quantification methods. The proposed method was also applied to assess the absorbed dose delivered to a bone metastasis following [131I]mIBG therapy for neuroblastoma including the associated uncertainty estimation. RESULTS: The method is accurate across a range of activities and in varied radioactivity distributions. Median percentage errors using the proposed method in no background, uniform backgrounds and non-uniform backgrounds were - 0.4%, - 0.3% and 1.7% with median associated uncertainties of 1.4%, 1.4% and 1.6%, respectively. The technique is more accurate and robust when compared to currently available alternative methods. CONCLUSIONS: The proposed method provides a reliable and accurate method for quantification of sources of interest, which are less than three times the spatial resolution of the imaging system. The method may be of use in absorbed dose calculation in cases of bone metastasis, lung metastasis or thyroid remnants.

14.
Eur J Nucl Med Mol Imaging ; 38 Suppl 1: S57-68, 2011 May.
Artigo em Inglês | MEDLINE | ID: mdl-21484382

RESUMO

This paper reviews issues concerning (86)Y positron emission tomography (PET), (90)Y PET and (90)Y bremsstrahlung imaging. Specific methods and corrections developed for quantitative imaging, for application in preclinical and clinical studies, and to assess (90)Y dosimetry are discussed. The potential imaging capabilities with the radioisotopes (87)Y and (88)Y are also considered. Additional studies required to assess specific unaddressed issues are also identified.


Assuntos
Tomografia por Emissão de Pósitrons/métodos , Radiometria/métodos , Radioisótopos de Ítrio/administração & dosagem , Radioisótopos de Ítrio/química , Animais , Previsões , Meia-Vida , Humanos , Compostos Radiofarmacêuticos/administração & dosagem , Compostos Radiofarmacêuticos/farmacocinética , Planejamento da Radioterapia Assistida por Computador/métodos , Distribuição Tecidual , Tomografia Computadorizada de Emissão/métodos
15.
Thyroid ; 31(12): 1829-1838, 2021 12.
Artigo em Inglês | MEDLINE | ID: mdl-34598656

RESUMO

Background: Patients with Graves' disease are commonly treated with radioiodine. There remains controversy over whether the aim of treatment should be to achieve euthyroidism or hypothyroidism, and whether treatments should be administered with standard levels of radioactivity or personalized according to the radiation absorbed doses delivered to the thyroid. The aim of this review was to investigate whether a relationship exists between radiation absorbed dose and treatment outcome. Methods: A systematic review and meta-analysis of all reports published before February 13, 2020, were performed using PubMed, Web of Science, OVID MEDLINE, and Embase. Proportion of patients achieving nonhyperthyroid status was the primary outcome. Secondary outcomes were proportion of patients who were specifically euthyroid or hypothyroid. A random-effects meta-analysis of proportions was performed for primary and secondary outcomes, and the impact of the radiation absorbed dose on treatment outcome was assessed through meta-regression. The study is registered with PROSPERO (CRD42020175010). Results: A total of 1122 studies were identified of which 15, comprising 2303 Graves' disease patients, were eligible for the meta-analysis. A strong association was found between radiation absorbed dose and nonhyperthyroid and hypothyroid outcomes (odds ratio [OR] = 1.11 [95% confidence interval {CI} 1.08-1.14] and OR = 1.09 [CI 1.06-1.12] per 10 Gy increase). Higher rates of euthyroid outcome were found for radiation absorbed doses within the range 120-180 Gy when compared with outside this range (n = 1172, OR = 2.50 [CI 1.17-5.35], p = 0.018). A maximum euthyroid response of 38% was identified at a radiation absorbed dose of 128 Gy. Conclusions: The presented radiation absorbed dose-response relationships can facilitate personalized treatment planning for radioiodine treatment of patients with Graves' disease. Further studies are required to determine how patient-specific covariates can inform personalized treatments.


Assuntos
Doença de Graves/radioterapia , Radioisótopos do Iodo/farmacocinética , Dosagem Radioterapêutica , Glândula Tireoide/efeitos da radiação , Humanos , Radioisótopos do Iodo/uso terapêutico
16.
Phys Med ; 89: 1-10, 2021 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-34339928

RESUMO

PURPOSE: The aims of this study were to develop and apply a method to correct for the differences in partial volume effects of pre-therapy Technetium-99 m (99mTc)-MAA SPECT and post-therapy Yttrium-90 (90Y) bremsstrahlung SPECT imaging in selective internal radiation therapy, and to use this method to improve quantitative comparison of predicted and delivered 90Y absorbed doses. METHODS: The spatial resolution of 99mTc SPECT data was converted to that of 90Y SPECT data using a function calculated from 99mTc and 90Y point spread functions. This resolution conversion method (RCM) was first applied to 99mTc and 90Y SPECT phantom data to validate the method, and then to clinical data to assess the power of 99mTc SPECT imaging to predict the therapeutic absorbed dose. RESULTS: The maximum difference between absorbed doses to phantom spheres was 178%. This was reduced to 27% after the RCM was applied. The clinical data demonstrated differences within 38% for mean absorbed doses delivered to the normal liver, which were reduced to 20% after application of the RCM. Analysis of clinical data showed that therapeutic absorbed doses delivered to tumours greater than 100 cm3 were predicted to within 52%, although there were differences of up to 210% for smaller tumours, even after the RCM was applied. CONCLUSIONS: The RCM was successfully verified using phantom data. Analysis of the clinical data established that the 99mTc pre-therapy imaging was predictive of the 90Y absorbed dose to the normal liver to within 20%, but had poor predictability for tumours smaller than 100 cm3.


Assuntos
Embolização Terapêutica , Neoplasias Hepáticas , Humanos , Microesferas , Agregado de Albumina Marcado com Tecnécio Tc 99m , Tomografia Computadorizada de Emissão de Fóton Único , Radioisótopos de Ítrio/uso terapêutico
17.
Eur J Nucl Med Mol Imaging ; 37(2): 270-5, 2010 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-19760413

RESUMO

PURPOSE: The aim of this study was to determine the range of absorbed doses delivered to thyroid remnants, blood, and red marrow from fixed administrations of radioiodine and to ascertain whether the success of ablation is more dependent on these absorbed doses than on the administered activity. METHODS: Twenty-three patients received 3,000 MBq radioiodine following near-total thyroidectomy. The maximum absorbed dose to remnants was calculated from subsequent single photon emission tomography scans. Absorbed doses delivered to blood and red marrow were calculated from blood samples and from whole-body retention measurements. The protein bound iodine (PBI) was also calculated. RESULTS: Maximum absorbed doses to thyroid remnants ranged from 7 to 570 Gy. Eighteen of the 23 patients had a successful ablation. A significant difference was seen between the absorbed doses delivered to thyroid remnants, blood, and red marrow for those patients that had a successful ablation compared to those with a failed ablation (p = 0.030, p = 0.043 and p = 0.048, respectively). The difference between the PBI values acquired at day 1 and day 6 were also indicative of response (p = 0.074). CONCLUSIONS: A successful ablation is strongly dependent on the absorbed dose to the thyroid remnant. Dosimetry-based personalized treatment can prevent both sub-optimal administrations, which entails further radioiodine therapy, and excessive administration of radioactivity, which increases the potential for radiation toxicity.


Assuntos
Radioisótopos do Iodo/uso terapêutico , Eficiência Biológica Relativa , Neoplasias da Glândula Tireoide/radioterapia , Adolescente , Adulto , Idoso , Relação Dose-Resposta à Radiação , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Radiometria , Cintilografia , Dosagem Radioterapêutica , Neoplasias da Glândula Tireoide/diagnóstico por imagem , Adulto Jovem
18.
Cancer Biother Radiopharm ; 35(7): 530-539, 2020 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-32429699

RESUMO

Introduction: Thorium-227 is an alpha-emitting radioisotope with potential therapeutic applications in targeted alpha therapy. Thorium-227 decays to Radium-223, which may have an independent biodistribution to that of the parent Thorium-227 radiopharmaceutical. Quantitative in vivo imaging with sodium iodide (NaI) detectors is challenging due to cross-talk between neighboring γ-photopeaks as well as scattered γ-photons. The aim of this work was to validate the use of a spectral analysis technique to estimate the activity of each isotope within a region of interest applied to a pair of conjugate view planar acquisitions, acquired at multiple energy windows. Methods: Energy spectra per unit activity arising from unscattered Thorium-227 photons and Radium-223 photons as well as from scattered photons were modeled. These spectra were scaled until the combination of these component spectra resulted in the closest match to the measured data in four energy windows. Results: Measured estimates of activity followed the known decay curves in phantoms representative of a human torso. The mean errors in estimating Thorium-227 and Radium-223 were 5.1% (range -8.0% to 40.0%) and 3.4% (range -50.0% to 48.7%), respectively. The differences between the integrals of the theoretical and estimated time activity curve were <10% for both Thorium-227 and Radium-223. Conclusion: γ-camera quantification of Thorium-227 and Radium-223 can be achieved by using multiple energy window acquisitions.


Assuntos
Modelos Teóricos , Compostos Radiofarmacêuticos/farmacocinética , Rádio (Elemento)/farmacocinética , Tório/farmacocinética , Câmaras gama , Humanos , Modelos Anatômicos , Imagens de Fantasmas , Radiometria/métodos , Espectrometria gama/instrumentação , Espectrometria gama/métodos , Distribuição Tecidual , Tronco/diagnóstico por imagem
19.
EJNMMI Phys ; 7(1): 63, 2020 Oct 12.
Artigo em Inglês | MEDLINE | ID: mdl-33044651

RESUMO

BACKGROUND: Internal dosimetry evaluation consists of a multi-step process ranging from imaging acquisition to absorbed dose calculations. Assessment of uncertainty is complicated and, for that reason, it is commonly ignored in clinical routine. However, it is essential for adequate interpretation of the results. Recently, the EANM published a practical guidance on uncertainty analysis for molecular radiotherapy based on the application of the law of propagation of uncertainty. In this study, we investigated the overall uncertainty on a sample of a patient following the EANM guidelines. The aim of this study was to provide an indication of the typical uncertainties that may be expected from performing dosimetry, to determine parameters that have the greatest effect on the accuracy of calculations and to consider the potential improvements that could be made if these effects were reduced. RESULTS: Absorbed doses and the relative uncertainties were calculated for a sample of 49 patients and a total of 154 tumours. A wide range of relative absorbed dose uncertainty values was observed (14-102%). Uncertainties associated with each quantity along the absorbed dose calculation chain (i.e. volume, recovery coefficient, calibration factor, activity, time-activity curve fitting, time-integrated activity and absorbed dose) were estimated. An equation was derived to describe the relationship between the uncertainty in the absorbed dose and the volume. The largest source of error was the VOI delineation. By postulating different values of FWHM, the impact of the imaging system spatial resolution on the uncertainties was investigated. DISCUSSION: To the best of our knowledge, this is the first analysis of uncertainty in molecular radiotherapy based on a cohort of clinical cases. Wide inter-lesion variability of absorbed dose uncertainty was observed. Hence, a proper assessment of the uncertainties associated with the calculations should be considered as a basic scientific standard. A model for a quick estimate of uncertainty without implementing the entire error propagation schema, which may be useful in clinical practice, was presented. Ameliorating spatial resolution may be in future the key factor for accurate absorbed dose assessment.

20.
Phys Med Biol ; 65(17): 175019, 2020 09 08.
Artigo em Inglês | MEDLINE | ID: mdl-32640429

RESUMO

Quality control tests of molecular imaging systems are hampered by the complexity of phantom preparation. It is proposed that radioisotopes can be directly incorporated into photo-polymer resins. Use of the radio-polymer in a 3D printer allows phantoms with more complex and reliable activity distributions to be produced whilst simplifying source preparation. Initial tests have been performed to determine the practicality of integrating Tc-99m into a photo-polymer and example phantoms produced to test suitability for quality control. Samples of build and support resins were extracted from the print cartridges of an Objet30Pro Polyjet 3D printer. The response of the resin to external factors including ionising radiation, light and dilution with Tc-99m pertechnetate were explored. After success of the initial tests the radio-polymer was used in the production of different phantoms. Radionuclide dose calibrator and gamma camera acquisitions of the phantoms were used to test accuracy of activity concentration, print consistency, uniformity and heterogeneous reproducibility. Tomographic phantoms were also produced including a uniform hot sphere, a complex configuration of spheres and interlacing torus's and a hot rod phantom. The coefficient of variation between repeat prints of a 12 g disk phantom was 0.08%. Measured activity within the disks agreed to within 98 ± 2% of the expected activity based on initial resin concentration. Gamma camera integral uniformity measured across a 3D printed flood field phantom was 5.2% compared to 6.0% measured with a commercial Co-57 flood source. Heterogeneous distributions of activity were successfully reproduced for both 2D and 3D imaging phantoms. Count concentration across regions of heterogeneity agreed with the planned activity assigned to those regions on the phantom design. 3D printing of radioactive phantoms has been successfully demonstrated and is a promising application for quality control of Positron Emission Tomography and Single Photon Emission Computed Tomography systems.


Assuntos
Imagem Molecular/instrumentação , Imagens de Fantasmas , Impressão Tridimensional , Calibragem , Humanos , Imageamento Tridimensional , Reprodutibilidade dos Testes , Tecnécio
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA