Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 13 de 13
Filtrar
1.
Orthopade ; 46(2): 142-147, 2017 Feb.
Artigo em Alemão | MEDLINE | ID: mdl-28083683

RESUMO

BACKGROUND: In case of hip revision arthroplasty, one component (cup/stem) is often well fixed and does not need to be exchanged. The newly implanted component needs to be compatible with the well-fixed implant. The combination of implants from different companies leads to "mix and match" or even mismatch between the implants. OBJECTIVES AND METHODS: The objective of this work was to describe possible combinations including their specifications that need to be considered in partial exchange of hip prostheses. For this purpose the literature, surgical techniques of companies and judgements concerning this topic were analysed and our own results and experiences were included. RESULTS AND CONCLUSIONS: Partial revision arthroplasty can be challenging and needs to be planned in detail. In case of isolated cup or inlay revision with exchange of a modular head the cone of the stem needs to be identified. A ceramic head may be used in revision with a titanium sleeve even from a different company as long as they are compatible. Patients however need to give their informed consent for this mix and match procedure. This procedure is done frequently and good study results support this, however from a juristic point of view a definite recommendation cannot be given. If the inlay of a cup is replaced, the original inlay should be used. If this is not available anymore, it can be manufactured as a special product in many cases. If this is also not possible, an inlay can also be cemented into a well-fixed cup. Biomechanical and clinical studies support this off-label technique. In case of an isolated exchange of the stem with a ceramic inlay that is retained in a well-fixed cup, the revision stem and ceramic head need to be from the same company as the cup. In case of ceramic fracture, a ceramic head with a titanium sleeve should be combined with a PE or ceramic inlay, a metal head or inlay should never be used.


Assuntos
Artroplastia de Quadril/instrumentação , Artroplastia de Quadril/métodos , Prótese de Quadril , Osteoartrite do Quadril/cirurgia , Reoperação/instrumentação , Reoperação/métodos , Acetabuloplastia/instrumentação , Acetabuloplastia/métodos , Acetábulo/cirurgia , Terapia Combinada , Medicina Baseada em Evidências , Humanos , Osteotomia/instrumentação , Osteotomia/métodos , Desenho de Prótese , Procedimentos de Cirurgia Plástica/instrumentação , Procedimentos de Cirurgia Plástica/métodos , Resultado do Tratamento
2.
Acta Chir Belg ; 113(2): 123-8, 2013.
Artigo em Inglês | MEDLINE | ID: mdl-23741931

RESUMO

BACKGROUND: Hip resurfacing arthroplasty is known to increase the metal ion concentration in the serum, urine and whole blood, with potentially adverse effects on the organism. However, only few data are available about the metal ion concentrations in erythrocytes, although they are directly exposed to the higher concentrations of the serum. METHODS: The ion levels of chromium, cobalt, nickel and molybdenum in erythrocytes of 25 patients with a hip resurfacing implant were analysed with high resolution ICP-sf-MS (inductively-coupled-plasma-sector-field-mass-spectrometry). The results were compared to the ion levels in the serum and urine of the patients, and also to the ion levels of 27 control persons without an implant. RESULTS: Compared to the control group, ion levels in the erythrocytes of the hip resurfacing group were markedly increased for cobalt (0.10 vs. 3.26 microg/kg) and slightly for chromium (6.04 vs. 7.38 microg/kg). In contrast, ion levels in the serum of the hip resurfacing group were increased for cobalt (0.21 vs. 1.92 microg/l), chromium (1.48 vs. 5.64 microg/l), nickel (1.53 vs. 4.25 microg/l) and molybdenum (2.17 vs. 3.78 microg/l). CONCLUSION: Ion concentrations of cobalt and chromium are also increased in erythrocytes after hip resurfacing arthroplasty. Further research is required to evaluate the impact of the elevated ion levels on the erythrocytes, and to evaluate if metal ions also accumulate in other tissues of the body.


Assuntos
Artroplastia de Quadril , Eritrócitos/metabolismo , Prótese de Quadril , Artropatias/metabolismo , Próteses Articulares Metal-Metal , Metais Pesados/metabolismo , Adulto , Estudos de Casos e Controles , Feminino , Humanos , Íons/sangue , Íons/urina , Artropatias/patologia , Artropatias/cirurgia , Masculino , Pessoa de Meia-Idade , Desenho de Prótese
3.
Orthopade ; 41(7): 552-9, 2012 Jul.
Artigo em Alemão | MEDLINE | ID: mdl-22732771

RESUMO

BACKGROUND: One of the main goals of the preoperative planning of hip prostheses is adequate shaft positioning with reconstruction of leg length and offset. The purpose of this study was to compare the planned and achieved shaft positions using a modified program for migration measurement. METHODS: In 60 cases of total hip replacement the preoperative planning was compared with the postoperative radiograph using a modified version of the well-established EBRA-FCA program. The results of this new measurement were compared to conventional measurements. In 25 cases the intraobserver and interobserver reliability was determined. RESULTS: The novel measurements correlated best with the measured distance between the greater trochanter and the center of rotation and yielded the best intraobserver and interobserver reliability. In general, cementless stems had a slightly more proximal position (0.65 mm) compared to cemented stems. CONCLUSIONS: The modified program for migration measurement facilitates a reproducible and fast comparison of the planned and achieved shaft positions thus implementing an early and objective control of postoperative shaft position.


Assuntos
Artroplastia de Quadril/instrumentação , Artroplastia de Quadril/métodos , Articulação do Quadril/diagnóstico por imagem , Articulação do Quadril/cirurgia , Instabilidade Articular/diagnóstico por imagem , Instabilidade Articular/cirurgia , Cuidados Pré-Operatórios/métodos , Idoso , Feminino , Humanos , Masculino , Radiografia , Recuperação de Função Fisiológica , Resultado do Tratamento
4.
Orthopade ; 40(10): 848, 850-2, 854, 2011 Oct.
Artigo em Alemão | MEDLINE | ID: mdl-21938492

RESUMO

The patellofemoral joint constitutes a complex anatomical and functional entity. The tensile force of the quadriceps femoris muscle is transmitted through the patella and patellar ligament onto the tibial tuberosity. This particular three-dimensional arrangement increases the torsional moment acting on the knee joint. Dynamic alignment of the patella is determined by trochlear geometry and is supported by active muscular and passive connective tissue stabilizers. In addition to the retinaculum of the patella, the medial patellofemoral ligament is attracting increasing clinical attention. Multidirectional motion of the patella is closely connected to retropatellar pressure distribution which can be modulated by moving the patellar ligament insertion. Implantation of a knee endoprosthesis changes the joint surface geometry and consequently patella kinematics and retropatellar pressure distribution. Finite element analysis provides the possibility to assess retropatellar pressure distribution before and after implantation of prostheses.


Assuntos
Artroplastia do Joelho , Articulação Patelofemoral/fisiopatologia , Complicações Pós-Operatórias/fisiopatologia , Fenômenos Biomecânicos/fisiologia , Análise de Elementos Finitos , Humanos , Patela/fisiopatologia , Luxação Patelar/fisiopatologia , Ligamento Patelar/fisiopatologia , Pressão , Desenho de Prótese , Músculo Quadríceps/fisiopatologia , Amplitude de Movimento Articular/fisiologia , Resistência à Tração/fisiologia , Torção Mecânica , Suporte de Carga/fisiologia
5.
Orthopade ; 40(7): 607-13, 2011 Jul.
Artigo em Alemão | MEDLINE | ID: mdl-21347859

RESUMO

BACKGROUND: Cementless hip cups require adequate primary stability in order to achieve osseointegration. Depending on implant design, a different biomechanical behavior in osteoporotic bone and in bone with normal bone mineral density might be expected. MATERIAL AND METHODS: The micromovement between bone and implant was determined in macerated human hip acetabula with reduced and with normal bone density for two different cementless screwed cups and two different cementless press-fit cups. The bone mineral density was assessed by means of Q-CT and 20 implantations were performed for each acetabulum with reduced and with normal bone density. RESULTS: Screwed cups showed significantly less micromovement than press-fit cups. The average micromovement of all cups, with the exception of the Monoblock cup, remained below the value of 100 µ, the upper limit for successful osseointegration. Values of over 200 µ were measured only for the Monoblock cup and only in some of the tests. There was no significant difference between the micro-movement in acetabula with reduced bone mineral density and with normal bone. CONCLUSION: Impaired osseointegration in osteoporotic bone because of increased micromovement is not to be expected in the investigated cementless hip cups as no relevant differences in micromovement were found between normal and osteoporotic bone stock. On the basis of the good clinical results with the Monoblock cup, the upper limit of 100 µ of micromotion for osseointegation in macerated bone is probably set too low.


Assuntos
Acetábulo/cirurgia , Prótese de Quadril , Osseointegração/fisiologia , Osteoporose/cirurgia , Complicações Pós-Operatórias/etiologia , Falha de Prótese , Acetábulo/fisiopatologia , Cimentos Ósseos , Parafusos Ósseos , Humanos , Osteoporose/fisiopatologia , Complicações Pós-Operatórias/fisiopatologia , Desenho de Prótese
6.
Proc Inst Mech Eng H ; 223(1): 45-52, 2009 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-19239066

RESUMO

In revision hip arthroplasty with bone defects of the proximal femur, a well-established treatment method is reconstruction with impacted allograft spongiosa chips and cemented implantation of a polished stem. Building on this principle of impacted bone grafting, a femoral implant, which is suited to uncemented hip arthroplasty as well as for uncemented revisions, was designed. This so-called compression-rotation stem (CR stem) is collarless and has flanks which compress the impacted bone chips during implantation and thereby increase the rotational stability. To evaluate the primary stability of this new shaft after impaction grafting, the micromotion was determined using six motion transducers. Under physiological loading conditions with simulation of the muscle activities at the proximal femur the application was dynamically loaded for 15,000 cycles with 1000 +/- 500 N and afterwards for 5000 cycles with 1300 +/- 1000 N. Uncemented CR stems and the control Exeter stems were implanted in a standardized manner according to the X-Change method. Therefore they were implanted into artificial femora that had been previously resected, hollowed, and filled with impacted human spongeous bone allograft to simulate bone defects. Subsequently, the femora were loaded under identical conditions and the micromotions measured. In the majority of the implantations, no significant differences could be found. In conclusion, similar clinical results for the two stems should be expected.


Assuntos
Análise de Falha de Equipamento , Cabeça do Fêmur/fisiopatologia , Cabeça do Fêmur/cirurgia , Prótese de Quadril , Instabilidade Articular/prevenção & controle , Modelos Biológicos , Força Compressiva , Simulação por Computador , Módulo de Elasticidade , Humanos , Instabilidade Articular/cirurgia , Movimento (Física) , Desenho de Prótese , Rotação , Estresse Mecânico
7.
Orthopade ; 38(4): 308, 310-12, 314-5, 2009 Apr.
Artigo em Alemão | MEDLINE | ID: mdl-19296081

RESUMO

Surgery in metastatic disease to the bone is the most common procedure in orthopaedic oncology. To assess an adequate therapeutic approach we analysed 513 surgeries performed on 453 patients between 1980 and 2005 and reviewed the literature.The most significant factor is the histology of the primary tumour. A biopsy is mandatory to confirm the diagnosis in an unknown primary tumour, especially in cases of solitary lesions. Pulmonary carcinoma has an unfavourable prognosis compared to breast and renal cell carcinoma patients. Radical resection in isolated metastatic disease in renal cell carcinoma reduces the risk of local recurrence and even may result in a long progression-free survival. In breast cancer osseous and visceral dissemination is the most decisive factor for prognosis. An interdisciplinary approach is mandatory in every patient.


Assuntos
Neoplasias Ósseas/secundário , Neoplasias Ósseas/cirurgia , Osteotomia/mortalidade , Biópsia , Neoplasias Ósseas/mortalidade , Neoplasias Ósseas/patologia , Intervalo Livre de Doença , Humanos , Incidência , Prognóstico , Medição de Risco/métodos , Fatores de Risco , Análise de Sobrevida , Taxa de Sobrevida
8.
Orthopade ; 38(5): 461-70; quiz 471-2, 2009 May.
Artigo em Alemão | MEDLINE | ID: mdl-19415234

RESUMO

Prognosis of cemented total hip replacement seems to be excellent for elderly patients. In younger age the outcome is less favourable and early revision is more common. Thus, different concepts with better prognosis and preservation of bone stock for possible revisions were needed. After more than 30 years of application with excellent short-term and long-term results, uncemented total hip arthroplasty is nowadays generally regarded as the standard procedure for younger patients. New bone-preserving implants, such as surface replacement or short-stemmed femoral shaft prostheses, have been introduced especially for younger patients. Some of these new procedures are still under development, and the long-term results of new implant concepts have to be evaluated over the next decades. Regarding recently published scientific studies an overview about non-cemented total hip arthroplasty is given and current concepts and developments are presented.


Assuntos
Artroplastia de Quadril/instrumentação , Artroplastia de Quadril/métodos , Articulação do Quadril/cirurgia , Prótese de Quadril , Instabilidade Articular/cirurgia , Cimentos Ósseos , Cimentação , Humanos , Desenho de Prótese
9.
Orthopade ; 36(10): 935-8, 940, 942-3, 2007 Oct.
Artigo em Alemão | MEDLINE | ID: mdl-17891377

RESUMO

In the event of a hip dislocation following THA analysis of its mechanism is the main priority. In addition, the time since the operation and the direction of the dislocation need to be taken into account. When the cause of the dislocation is analysed the formation of the neocapsule plays a part at least in the case of early dislocations (within the first 6 weeks after the operation). Most dislocations happen during this postoperative period, and these can usually be treated nonoperatively by closed reduction with only a short period of general anaesthesia. Late dislocations (in the 7th and subsequent postoperative week) generally occur because of malpositioning or migration of the components of the prosthesis and quite often do need operative treatment. Dislocation after implantation of a total hip replacement is a serious complication; it should be treated quickly, and initially it confronts the operator with many unanswered questions, from the causes to their treatment.


Assuntos
Artroplastia de Quadril/instrumentação , Artroplastia de Quadril/estatística & dados numéricos , Lesões do Quadril/epidemiologia , Lesões do Quadril/cirurgia , Luxações Articulares/epidemiologia , Falha de Prótese , Análise de Falha de Equipamento/estatística & dados numéricos , Humanos , Incidência , Desenho de Prótese
10.
Oper Orthop Traumatol ; 26(2): 171-83, 2014 Apr.
Artigo em Alemão | MEDLINE | ID: mdl-24699924

RESUMO

OBJECTIVE: Total hip arthroplasty with a minimal-incision technique that can be performed in the widely used supine position. The accustomed and good overview of this position allows safe positioning of the implant and combines this with the advantage of a soft tissue preserving technique. All standard instruments and implants can be further applied. INDICATIONS: Primary and secondary coxarthrosis, femoral head necrosis. CONTRAINDICATIONS: Revision surgery, severe anatomic deformity, implantation of hip resurfacing arthroplasty. SURGICAL TECHNIQUE: Supine position. The skin incision runs from the innominate tubercle proximally and falls slightly in the dorsal direction (20-30°). Incision of the iliotibial tract and exposure of the vastogluteal muscle sling. Starting from the greater trochanter, the sinewy onset of the minimal and medium gluteal muscle is split with an arched-shaped incision, which also falls proximally in the dorsal direction. Exposition of the joint capsule, longitudinal incision and resection of the ventrolateral parts. Dislocation of the hip by a combined adduction and external rotation movement. Osteotomy of the femoral neck and resection of the femoral head are performed in a figure-of-four position without adduction. To prepare the acetabulum and to insert the cup, the leg is placed in neutral position with a slight flexion of 20° in the hip. Preparation of the femur and implantation of the stem is again performed in a figure-of-four position in adduction. Reduction of the hip and stepwise wound closure. POSTOPERATIVE MANAGEMENT: Mobilization on postoperative day 1. Starting with half weight bearing and after completed wound healing rapid increase to full weight bearing. Intensive physiotherapy and rehabilitation. Thrombosis prophylaxis according to guidelines. RESULTS: The mini-incision approach has successfully been used in our clinic for years. Between September 2004 and November 2005, the less-invasive technique was evaluated in a randomized controlled trial with 51 patients (52 hips). Compared to the standard approach a significantly shorter incision length (8.9 vs. 14.0 cm) and a slightly lower blood loss (502 vs. 660 ml) were observed for the modified mini-Hardinge. Moreover, the mini-incision group showed slightly better functional results in the early course. A higher rate of implant malpositioning or a higher peri- and postoperative complication rate was not observed.


Assuntos
Artroplastia de Quadril/métodos , Necrose da Cabeça do Fêmur/cirurgia , Procedimentos Cirúrgicos Minimamente Invasivos/métodos , Osteoartrite do Quadril/cirurgia , Posicionamento do Paciente/métodos , Fraturas Periprotéticas/cirurgia , Feminino , Necrose da Cabeça do Fêmur/diagnóstico por imagem , Humanos , Masculino , Pessoa de Meia-Idade , Osteoartrite do Quadril/diagnóstico por imagem , Fraturas Periprotéticas/diagnóstico por imagem , Radiografia , Decúbito Dorsal , Resultado do Tratamento
11.
Z Orthop Unfall ; 148(2): 168-73, 2010 Mar.
Artigo em Alemão | MEDLINE | ID: mdl-20376759

RESUMO

For decades the cemented anchorage of hip prostheses, especially for elderly patients, is the standard procedure. The cementing technique has turned out to be the determining factor for the survival of the implant. In the last few years developments in this field have been able to further improve the long-term survival. Established components of the modern cementing technique are vacuum-mixed cements, medullary canal plugs, centralising elements und the use of jet-lavages. The design of the cemented shaft depends on the more important surface finish. In the most clinical studies, polished shafts turned out to be slightly superior as compared to shafts with rough surfaces.


Assuntos
Artroplastia de Quadril/métodos , Cimentos Ósseos/uso terapêutico , Idoso , Fenômenos Biomecânicos , Análise de Falha de Equipamento , Humanos , Desenho de Prótese , Temperatura
12.
Arch Orthop Trauma Surg ; 127(6): 397-401, 2007 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-17602233

RESUMO

INTRODUCTION: A new femoral stem was developed with a design that leads to compression of cancellous bone in the calcar region which results in proximal loading. The cross-sectional design of the implant provides rotational stability. MATERIALS AND METHODS: In the first clinical investigation ten patients underwent uncemented total hip arthroplasty between January 1999 and May 1999 using the CR-stem((R)) (Implantcast GmbH, Buxtehude, Germany). Results were investigated using the Harris-hip-score (HHS) and antero-posterior and lateral radiographs. Migration was evaluated with the EBRA-FCA-method with a follow-up of 7 years. RESULTS: We demonstrated a mean subsidence rate of 2.23 +/- 1.13 mm 7 years after implantation thus providing basic data for extensive testing in a clinical environment. DISCUSSION: As small subsidence rates are regarded as predictor for superior long-term results in uncemented total hip arthroplasty according to the literature, the CR-stem shows promise for excellent long-term results.


Assuntos
Artroplastia de Quadril , Prótese de Quadril , Adulto , Idoso , Seguimentos , Humanos , Pessoa de Meia-Idade , Desenho de Prótese , Rotação , Resultado do Tratamento
13.
Radiologe ; 46(9): 785-93, 2006 Sep.
Artigo em Alemão | MEDLINE | ID: mdl-16612604

RESUMO

The implantation of a knee arthroplasty is still a demanding operation. There is still no "golden standard" available, although a lot of guidelines have been declared. Because of this fact this article should provide the radiologist with an overview of and some background knowledge for the radiological evaluation of knee arthroplasty.


Assuntos
Prótese do Joelho , Osteoartrite do Joelho/cirurgia , Complicações Pós-Operatórias/diagnóstico por imagem , Desenho de Prótese , Falha de Prótese , Seguimentos , Humanos , Osteoartrite do Joelho/diagnóstico por imagem , Radiografia , Amplitude de Movimento Articular/fisiologia , Sensibilidade e Especificidade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA