Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 9 de 9
Filtrar
1.
Proc Natl Acad Sci U S A ; 119(3)2022 01 18.
Artigo em Inglês | MEDLINE | ID: mdl-35022244

RESUMO

Experimental data and a suitable material model for human aortas with smooth muscle activation are not available in the literature despite the need for developing advanced grafts; the present study closes this gap. Mechanical characterization of human descending thoracic aortas was performed with and without vascular smooth muscle (VSM) activation. Specimens were taken from 13 heart-beating donors. The aortic segments were cooled in Belzer UW solution during transport and tested within a few hours after explantation. VSM activation was achieved through the use of potassium depolarization and noradrenaline as vasoactive agents. In addition to isometric activation experiments, the quasistatic passive and active stress-strain curves were obtained for circumferential and longitudinal strips of the aortic material. This characterization made it possible to create an original mechanical model of the active aortic material that accurately fits the experimental data. The dynamic mechanical characterization was executed using cyclic strain at different frequencies of physiological interest. An initial prestretch, which corresponded to the physiological conditions, was applied before cyclic loading. Dynamic tests made it possible to identify the differences in the viscoelastic behavior of the passive and active tissue. This work illustrates the importance of VSM activation for the static and dynamic mechanical response of human aortas. Most importantly, this study provides material data and a material model for the development of a future generation of active aortic grafts that mimic natural behavior and help regulate blood pressure.


Assuntos
Aorta/fisiologia , Fenômenos Biomecânicos , Músculo Liso Vascular/fisiologia , Adenosina , Adulto , Idoso , Alopurinol , Glutationa , Humanos , Insulina , Pessoa de Meia-Idade , Modelos Biológicos , Músculo Liso Vascular/citologia , Soluções para Preservação de Órgãos , Rafinose , Estresse Mecânico
2.
J Mech Behav Biomed Mater ; 153: 106492, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38479211

RESUMO

The effect of residual stresses on the deformation of human aortas under pulsatile pressure is relevant. Experimental measurements of residual deformations are necessary to characterize residual stresses in human aortas. For this reason, an experimental study is carried out. In the present study, longitudinal and circumferential strips from descending thoracic aortas obtained from 21 donors, harvested during organ donation explant, underwent residual deformation measurements. The intact wall and the three separated layers were tested in both directions, resulting in 8 tests per donor, which gives a relevant set of experimental data for further studies. Results show significant residual deformations both in circumferential and longitudinal directions, which are compatible with a significantly compressed intima in the unloaded aorta. In particular, the measured mean effective curvature was -0.193 ± 0.064 (1/mm) for the circumferential strips and -0.076 ± 0.030 (1/mm) for longitudinal strips of the full wall. The effects of age and gender were also investigated.


Assuntos
Aorta Torácica , Aorta , Humanos , Estresse Mecânico , Pressão , Fenômenos Biomecânicos
3.
J Mech Behav Biomed Mater ; 148: 106216, 2023 12.
Artigo em Inglês | MEDLINE | ID: mdl-37924665

RESUMO

A human aorta from a female donor affected by Klippel-Trenaunay syndrome was retrieved during a surgery for organ donation for transplant. The aorta was preserved in refrigerated Belzer UW organ preservation solution and tested within a few hours for mechanical characterization with and without vascular smooth muscle activation. KCl and Noradrenaline were used as vasoactive agents in bubbled Krebs-Henseleit buffer solution at 37 °C. A quasi-static and a dynamic mechanical characterization of the full wall and the three individual layers were carried out for strips taken in longitudinal and circumferential directions. The full wall in the descending portion of the aorta underwent mechanical tests with and without smooth muscle activation. Results were compared to data obtained from healthy aortas and show a reduced stiffness of the full wall in circumferential direction. Also, a significant reduction of the response to vasoactive agents in circumferential direction was observed, while the longitudinal response was similar to healthy cases.


Assuntos
Aorta Torácica , Síndrome de Klippel-Trenaunay-Weber , Humanos , Feminino , Aorta Torácica/fisiologia , Aorta , Norepinefrina , Músculo Liso Vascular
4.
Acta Biomater ; 160: 59-72, 2023 04 01.
Artigo em Inglês | MEDLINE | ID: mdl-36792047

RESUMO

Decellularized porcine aortas are proposed as scaffolds for revolutionary active aortic grafts. A change in the static and dynamic mechanical properties, associated with the microstructure of elastin and collagen fibers, corresponds to alteration in the cyclic expansion and perfusion, in addition to possible graft damage. Therefore, the present study thoroughly investigates the mechanical response of the decellularized scaffolds of human and porcine origin to static and dynamic mechanical loads. The responses of the native human and porcine aortas are also compared; this is unavailable in the literature. Because the aorta is subjected to pulsatile blood pressure, dynamical responses to cyclic loads and their associated viscoelastic properties are particularly relevant for advanced graft design. In parallel, this study examines the microstructure of the decellularized aorta. The resulting data are compared to the analogous data obtained for the native human and porcine tissues. The results indicate that by using an optimized decellularization protocol - based on sodium dodecyl sulfate (SDS) and DNase - that minimizes mechanical and structural changes of the tissue, layered scaffolds with static and dynamic properties very similar to natural human aortas are obtained. In particular, a decellularized porcine aorta is non-inferior to a decellularized human aorta. STATEMENT OF SIGNIFICANCE: About 55,000 patients undergo abdominal aortic aneurysm repair annually in the USA. The currently implanted grafts present a large mechanical mismatch with the native tissue. This increases the pulsatile nature of the blood flow with negative consequences to the organ perfusion. For this reason, biomimetic and mechanically compatible grafts for aortic repair are urgently needed and they can be obtained through tissue engineering. In this study, scaffolds from porcine and human aortas are obtained from an optimized decellularization protocol. They are accurately compared to the native tissue and present the ideal static and dynamic mechanical properties for developing innovative aortic grafts.


Assuntos
Aorta , Engenharia Tecidual , Suínos , Humanos , Animais , Engenharia Tecidual/métodos , Dodecilsulfato de Sódio/química , Alicerces Teciduais , Matriz Extracelular/química
5.
J Mech Behav Biomed Mater ; 130: 105205, 2022 06.
Artigo em Inglês | MEDLINE | ID: mdl-35390678

RESUMO

Healthy human descending thoracic aortas, obtained during organ donation for transplant and research, were tested in a mock circulatory loop to measure the mechanical response to physiological pulsatile pressure and flow. The viscoelastic properties of the aortic segments were investigated at three different pulse rates. The same aortic segments were also subjected to quasi-static pressure tests in order to identify the aortic dynamic stiffness ratio, which is defined as the ratio between the stiffness in case of pulsatile pressure and the stiffness measured for static pressurization, both at the same value of pressure. The loss factor was also identified. The shape of the deformed aorta under static and dynamic pressure was measured by image processing to verify the compatibility of the end supports with the natural deformation of the aorta in the human body. In addition, layer-specific experiments on 10 human descending thoracic aortas allowed to precisely identify the mass density of the aortic tissue, which is an important parameter in cardiovascular dynamic models.


Assuntos
Aorta Torácica , Rigidez Vascular , Aorta/fisiologia , Aorta Torácica/fisiologia , Humanos , Modelos Cardiovasculares , Viscosidade
6.
Acta Biomater ; 130: 291-307, 2021 08.
Artigo em Inglês | MEDLINE | ID: mdl-34082105

RESUMO

Experiments were carried out on 15 human descending thoracic aortas from heart-beating healthy donors who donated organs for transplant. The aortas were kept refrigerated in organ preservation solution and tested were completed within 48 hours from explant. Donors' age was comprised between 25 and 70 years, with an average of 51.7 ± 12.8 years. Quasi-static and dynamic uniaxial tensile test were carried out in thermally controlled physiological saline solution in order to characterize the viscoelastic behavior. Strips were tested under harmonic deformation of different frequency, between 1 and 11 Hz, at three initial pre-stretches. Cyclic deformations of two different amplitudes were used: a physiological one and a small one, the latter one for comparison purposes to understand the accuracy limits of viscoelastic models. Aortic strips in circumferential and longitudinal directions were cut from each aorta. Some strips were dissected to separate the three layers: intima, media and adventitia. They were tested individually in order to obtain layer-specific data. However, strips of the intact wall were also tested. Therefore, 8 strips per donors were tested. Viscoelastic parameters are accurately evaluated from the hysteresis loops. Results show that small-amplitude cyclic strain over-estimate the storage modulus and under-estimate the loss-factor. Therefore, cyclic deformation of physiological amplitude is necessary to obtain correct viscoelastic data of aortic tissue. The value of the applied pre-stretch is significant on the dynamic stiffness ratio (storage modulus divided by the corresponding quasi-static stiffness), while it is less significant for the loss factor. The median of the dynamic stiffness ratios, in physiological conditions, varies between 1.14 and 1.33 for the different layers and the intact wall; the corresponding median of the loss factors varies between 0.050 and 0.066. The lowest dynamic stiffness ratios and loss factors were obtained from donors of the youngest age group. STATEMENT OF SIGNIFICANCE: There is an increasing interest in replacing traditional Dacron grafts used to repair thoracic aortas after acute dissection and aneurysm, with grafts in innovative biomaterials that mimic the mechanical properties and the dynamic behavior of the aorta. The human aorta is a complex laminated structure with hyperelastic and viscoelastic material properties and residual stresses. This study aims to characterize the nonlinear viscoelastic properties of ex-vivo human descending thoracic aortas by measuring hysteresis loops of physiological amplitude under harmonic strain. Results show the necessity to characterize the viscoelastic material properties of the aorta under physiological conditions, as well as the necessity to introduce improved models that take better into account the influence of the initial pre-stretch and amplitude of the cyclic load.


Assuntos
Aorta Torácica , Aorta , Adulto , Túnica Adventícia , Idoso , Fenômenos Biomecânicos , Elasticidade , Coração , Humanos , Pessoa de Meia-Idade , Estresse Mecânico
7.
Acta Biomater ; 134: 401-421, 2021 10 15.
Artigo em Inglês | MEDLINE | ID: mdl-34303867

RESUMO

The mechanical properties of human aortas are linked to the layered tissue and its microstructure at different length scales. Each layer has specific mechanical and structural properties. While the ground substance and the elastin play an important role in tissue stiffness at small strain, collagen fibers carry most of the load at larger strains, which corresponds to the physiological conditions of the aorta at maximum pulsatile blood pressure. In fact, collagen fibers are crimped in the unloaded state. Collagen fibers show different orientation distributions when they are observed in a plane that is tangent to the aortic wall (in-plane section) or along a direction orthogonal to it (out-of-plane section). This was systematically investigated using large images (2500 × 2500 µm) with high resolution obtained by second harmonic generation (SHG) in order to homogenize tissue heterogeneity after a convergence analysis, which is a main goal of the study. In addition, collagen fibers show lateral interactions due to entanglements and the presence of transverse elastin fibers, observed on varying length scales using atomic force microscopy and a three-dimensional rendering obtained by stacking a sequence of SHG and two-photon fluorescence images; this is another important contribution. Human descending thoracic aortas from 13 heartbeat donors aged 28 to 66 years were examined. Uniaxial tensile tests were carried out on the longitudinal and circumferential strips of the aortic wall and the three separated layers (intima, media and adventitia). A structurally-motivated material model with (i) a term to describe the combined response of ground substance and elastin and (ii) terms to consider four families of collagen fibers with different directions was applied. The exclusion of compressed fibers was implemented in the fitting process of the experimental data, which was optimized by a genetic algorithm. The results show that a single fiber family with directional and dispersion parameters measured from SHG images can describe the mechanical response of all 39 layers (3 layers for each of the 13 aortas) with very good accuracy when a second (auxiliary) family of aligned fibers is introduced in the orthogonal direction to account for lateral fiber interaction. Indeed, all observed distributions of collagen directions can be accurately fitted by a single bivariate von Mises distribution. Statistical analysis of in-plane and out-of-plane dispersion of fiber orientations reveals structural differences between the three layers and a change of collagen dispersion parameters with age. STATEMENT OF SIGNIFICANCE: The stiffness of healthy young aortas is adjusted so that a diameter expansion of about 10 % is possible during the heartbeat. This creates the Windkessel effect, which smooths out the pulsating nature of blood flow and benefits organ perfusion. The specific elastic properties of the aorta that are required to achieve this effect are related to the microstructure of the aortic tissue at different length scales. An increase in the aortic stiffness, in addition to reducing cyclic expansion and worsening perfusion, is a risk factor for clinical hypertension. The present study relates the microstructure of healthy human aortas to the mechanical response and examines the changes in microstructural parameters with age, which is a key factor in increasing stiffness.


Assuntos
Aorta Torácica , Elastina , Túnica Adventícia , Aorta , Fenômenos Biomecânicos , Humanos , Estresse Mecânico
8.
J Mech Behav Biomed Mater ; 112: 104079, 2020 12.
Artigo em Inglês | MEDLINE | ID: mdl-33126083

RESUMO

The effect of the exclusion of the compressed fibers in the identification of material parameters from uniaxial tensile tests on two orthogonal strips is investigated. The micro-structurally based constitutive model with two dispersion parameters developed by Holzapfel and his colleagues is utilized in the study. A new exclusion method, based on the coefficient reflecting the percentage of stretched fibers, is proposed. The material parameters are identified by using experimental data from 30 uniaxial tensile tests (5 donors, 6 strips per donor) and a genetic algorithm code that is capable to find the optimal set of parameters. The contraction of the strip width computed by using the hyperelastic model with the identified material parameters is compared to the experimental data for two human aortas (one from literature and one experiment, specific for this study), in order to show the accuracy of the identified model. The complex behavior of the thickness deformation of the strip is also obtained and compared to the experimental data derived from in-plane measurements and the incompressibility condition. Results show that the in-plane fiber exclusion is appropriate for aortic material characterization with uniaxial tensile tests, reducing very significantly the computational cost. At the same time, thickness growth of strips during uniaxial tests is possible, depending on fiber dispersion and orientation.


Assuntos
Aorta , Modelos Biológicos , Elasticidade , Humanos , Pressão , Estresse Mecânico , Resistência à Tração
9.
J Mech Behav Biomed Mater ; 110: 103804, 2020 10.
Artigo em Inglês | MEDLINE | ID: mdl-32898986

RESUMO

In vascular surgery, most synthetic vascular grafts currently used for large vessels replacements are made of Dacron (polyethylene terephthalate; PET). In this study, the dynamic response of these synthetic arterial substitutes to physiological pulsatile conditions is investigated in depth. Experiments were performed on a mock circulatory loop developed to replicate physiological pulsatile pressure and flow. Two different models of Dacron grafts (branched and straight) were tested at various heart rate conditions. Results are presented in terms of cyclic axisymmetric diameter changes, hysteretic loops of the pressure-diameter change, and viscoelastic parameters, such as loss factor and storage modulus that are identified from the hysteresis loop. The amplitude of cyclic diameter change of the Dacron graft was found to be always below 0.2% for all the heart rates considered (from 57 to 187 bpm). The loss factor of the Dacron graft slightly increased with the heart rate; almost no effect of the pulse rate was observed on the storage modulus, which was identified to be around 100 MPa. Both glycerol-water mixture (i.e. the blood analogue fluid) and saline solution were used in the circulatory loop and results did not present significant differences between the two cases. This shows that the effect of the shear load on the dynamic response of Dacron grafts is negligible. A comparison between Dacron vascular implants and human thoracic aortas shows a large mismatch in their viscoelastic mechanical properties.


Assuntos
Prótese Vascular , Polietilenotereftalatos , Humanos , Pressão , Fluxo Pulsátil , Procedimentos Cirúrgicos Vasculares
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA