Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 617
Filtrar
Mais filtros

Intervalo de ano de publicação
1.
Cell ; 181(2): 293-305.e11, 2020 04 16.
Artigo em Inglês | MEDLINE | ID: mdl-32142653

RESUMO

Pulmonary tuberculosis, a disease caused by Mycobacterium tuberculosis (Mtb), manifests with a persistent cough as both a primary symptom and mechanism of transmission. The cough reflex can be triggered by nociceptive neurons innervating the lungs, and some bacteria produce neuron-targeting molecules. However, how pulmonary Mtb infection causes cough remains undefined, and whether Mtb produces a neuron-activating, cough-inducing molecule is unknown. Here, we show that an Mtb organic extract activates nociceptive neurons in vitro and identify the Mtb glycolipid sulfolipid-1 (SL-1) as the nociceptive molecule. Mtb organic extracts from mutants lacking SL-1 synthesis cannot activate neurons in vitro or induce cough in a guinea pig model. Finally, Mtb-infected guinea pigs cough in a manner dependent on SL-1 synthesis. Thus, we demonstrate a heretofore unknown molecular mechanism for cough induction by a virulent human pathogen via its production of a complex lipid.


Assuntos
Tosse/fisiopatologia , Glicolipídeos/metabolismo , Nociceptores/fisiologia , Fatores de Virulência/metabolismo , Adulto , Animais , Linhagem Celular , Tosse/etiologia , Tosse/microbiologia , Feminino , Glicolipídeos/fisiologia , Cobaias , Interações Hospedeiro-Patógeno , Humanos , Lipídeos/fisiologia , Pulmão/microbiologia , Macrófagos/microbiologia , Masculino , Camundongos , Mycobacterium tuberculosis/metabolismo , Mycobacterium tuberculosis/patogenicidade , Cultura Primária de Células , Tuberculose/microbiologia , Tuberculose Pulmonar/microbiologia , Tuberculose Pulmonar/fisiopatologia , Fatores de Virulência/fisiologia
2.
Cell ; 165(4): 867-81, 2016 May 05.
Artigo em Inglês | MEDLINE | ID: mdl-27133164

RESUMO

Fanconi anemia (FA) pathway genes are important tumor suppressors whose best-characterized function is repair of damaged nuclear DNA. Here, we describe an essential role for FA genes in two forms of selective autophagy. Genetic deletion of Fancc blocks the autophagic clearance of viruses (virophagy) and increases susceptibility to lethal viral encephalitis. Fanconi anemia complementation group C (FANCC) protein interacts with Parkin, is required in vitro and in vivo for clearance of damaged mitochondria, and decreases mitochondrial reactive oxygen species (ROS) production and inflammasome activation. The mitophagy function of FANCC is genetically distinct from its role in genomic DNA damage repair. Moreover, additional genes in the FA pathway, including FANCA, FANCF, FANCL, FANCD2, BRCA1, and BRCA2, are required for mitophagy. Thus, members of the FA pathway represent a previously undescribed class of selective autophagy genes that function in immunity and organellar homeostasis. These findings have implications for understanding the pathogenesis of FA and cancers associated with mutations in FA genes.


Assuntos
Proteína do Grupo de Complementação C da Anemia de Fanconi/metabolismo , Animais , Autofagia , Embrião de Mamíferos/citologia , Proteína do Grupo de Complementação C da Anemia de Fanconi/genética , Proteínas de Grupos de Complementação da Anemia de Fanconi/metabolismo , Fibroblastos/metabolismo , Células HeLa , Herpesvirus Humano 1/metabolismo , Humanos , Inflamassomos/metabolismo , Camundongos , Mitofagia , Espécies Reativas de Oxigênio/metabolismo , Sindbis virus/metabolismo
3.
Cell ; 157(3): 636-50, 2014 Apr 24.
Artigo em Inglês | MEDLINE | ID: mdl-24766809

RESUMO

CLP1 is a RNA kinase involved in tRNA splicing. Recently, CLP1 kinase-dead mice were shown to display a neuromuscular disorder with loss of motor neurons and muscle paralysis. Human genome analyses now identified a CLP1 homozygous missense mutation (p.R140H) in five unrelated families, leading to a loss of CLP1 interaction with the tRNA splicing endonuclease (TSEN) complex, largely reduced pre-tRNA cleavage activity, and accumulation of linear tRNA introns. The affected individuals develop severe motor-sensory defects, cortical dysgenesis, and microcephaly. Mice carrying kinase-dead CLP1 also displayed microcephaly and reduced cortical brain volume due to the enhanced cell death of neuronal progenitors that is associated with reduced numbers of cortical neurons. Our data elucidate a neurological syndrome defined by CLP1 mutations that impair tRNA splicing. Reduction of a founder mutation to homozygosity illustrates the importance of rare variations in disease and supports the clan genomics hypothesis.


Assuntos
Doenças do Sistema Nervoso Central/genética , Mutação de Sentido Incorreto , Proteínas Nucleares/metabolismo , Doenças do Sistema Nervoso Periférico/genética , Fosfotransferases/metabolismo , RNA de Transferência/metabolismo , Fatores de Transcrição/metabolismo , Anormalidades Múltiplas/genética , Anormalidades Múltiplas/patologia , Animais , Doenças do Sistema Nervoso Central/patologia , Cérebro/patologia , Pré-Escolar , Endorribonucleases/metabolismo , Feminino , Fibroblastos/metabolismo , Humanos , Lactente , Masculino , Camundongos , Camundongos Endogâmicos CBA , Microcefalia/genética , Doenças do Sistema Nervoso Periférico/patologia , RNA de Transferência/genética , Proteínas de Ligação a RNA
4.
Circulation ; 149(9): 644-655, 2024 02 27.
Artigo em Inglês | MEDLINE | ID: mdl-37883682

RESUMO

BACKGROUND: The optimal treatment in patients with severe aortic stenosis and small aortic annulus (SAA) remains to be determined. This study aimed to compare the hemodynamic and clinical outcomes between transcatheter aortic valve replacement (TAVR) and surgical aortic valve replacement (SAVR) in patients with a SAA. METHODS: This prospective multicenter international randomized trial was performed in 15 university hospitals. Participants were 151 patients with severe aortic stenosis and SAA (mean diameter <23 mm) randomized (1:1) to TAVR (n=77) versus SAVR (n=74). The primary outcome was impaired valve hemodynamics (ie, severe prosthesis patient mismatch or moderate-severe aortic regurgitation) at 60 days as evaluated by Doppler echocardiography and analyzed in a central echocardiography core laboratory. Clinical events were secondary outcomes. RESULTS: The mean age of the participants was 75.5±5.1 years, with 140 (93%) women, a median Society of Thoracic Surgeons predicted risk of mortality of 2.50% (interquartile range, 1.67%-3.28%), and a median annulus diameter of 21.1 mm (interquartile range, 20.4-22.0 mm). There were no differences between groups in the rate of severe prosthesis patient mismatch (TAVR, 4 [5.6%]; SAVR, 7 [10.3%]; P=0.30) and moderate-severe aortic regurgitation (none in both groups). No differences were found between groups in mortality rate (TAVR, 1 [1.3%]; SAVR, 1 [1.4%]; P=1.00) and stroke (TAVR, 0; SAVR, 2 [2.7%]; P=0.24) at 30 days. After a median follow-up of 2 (interquartile range, 1-4) years, there were no differences between groups in mortality rate (TAVR, 7 [9.1%]; SAVR, 6 [8.1%]; P=0.89), stroke (TAVR, 3 [3.9%]; SAVR, 3 [4.1%]; P=0.95), and cardiac hospitalization (TAVR, 15 [19.5%]; SAVR, 15 [20.3%]; P=0.80). CONCLUSIONS: In patients with severe aortic stenosis and SAA (women in the majority), there was no evidence of superiority of contemporary TAVR versus SAVR in valve hemodynamic results. After a median follow-up of 2 years, there were no differences in clinical outcomes between groups. These findings suggest that the 2 therapies represent a valid alternative for treating patients with severe aortic stenosis and SAA, and treatment selection should likely be individualized according to baseline characteristics, additional anatomical risk factors, and patient preference. However, the results of this study should be interpreted with caution because of the limited sample size leading to an underpowered study, and need to be confirmed in future larger studies. REGISTRATION: URL: https://www.clinicaltrials.gov; Unique identifier: NCT03383445.


Assuntos
Insuficiência da Valva Aórtica , Estenose da Valva Aórtica , Implante de Prótese de Valva Cardíaca , Próteses Valvulares Cardíacas , Acidente Vascular Cerebral , Substituição da Valva Aórtica Transcateter , Humanos , Feminino , Idoso , Idoso de 80 Anos ou mais , Masculino , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Insuficiência da Valva Aórtica/diagnóstico por imagem , Insuficiência da Valva Aórtica/cirurgia , Insuficiência da Valva Aórtica/etiologia , Estudos Prospectivos , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Resultado do Tratamento , Substituição da Valva Aórtica Transcateter/efeitos adversos , Fatores de Risco , Acidente Vascular Cerebral/etiologia
5.
Eur Heart J ; 45(21): 1904-1916, 2024 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-38554125

RESUMO

BACKGROUND AND AIMS: There is significant potential to streamline the clinical pathway for patients undergoing transcatheter aortic valve implantation (TAVI). The purpose of this study was to evaluate the effect of implementing BENCHMARK best practices on the efficiency and safety of TAVI in 28 sites in 7 European countries. METHODS: This was a study of patients with severe symptomatic aortic stenosis (AS) undergoing TAVI with balloon-expandable valves before and after implementation of BENCHMARK best practices. Principal objectives were to reduce hospital length of stay (LoS) and duration of intensive care stay. Secondary objective was to document patient safety. RESULTS: Between January 2020 and March 2023, 897 patients were documented prior to and 1491 patients after the implementation of BENCHMARK practices. Patient characteristics were consistent with a known older TAVI population and only minor differences. Mean LoS was reduced from 7.7 ± 7.0 to 5.8 ± 5.6 days (median 6 vs. 4 days; P < .001). Duration of intensive care was reduced from 1.8 to 1.3 days (median 1.1 vs. 0.9 days; P < .001). Adoption of peri-procedure best practices led to increased use of local anaesthesia (96.1% vs. 84.3%; P < .001) and decreased procedure (median 47 vs. 60 min; P < .001) and intervention times (85 vs. 95 min; P < .001). Thirty-day patient safety did not appear to be compromised with no differences in all-cause mortality (0.6% in both groups combined), stroke/transient ischaemic attack (1.4%), life-threatening bleeding (1.3%), stage 2/3 acute kidney injury (0.7%), and valve-related readmission (1.2%). CONCLUSIONS: Broad implementation of BENCHMARK practices contributes to improving efficiency of TAVI pathway reducing LoS and costs without compromising patient safety.


Assuntos
Estenose da Valva Aórtica , Benchmarking , Tempo de Internação , Substituição da Valva Aórtica Transcateter , Humanos , Substituição da Valva Aórtica Transcateter/métodos , Estenose da Valva Aórtica/cirurgia , Masculino , Feminino , Idoso de 80 Anos ou mais , Tempo de Internação/estatística & dados numéricos , Idoso , Procedimentos Clínicos , Europa (Continente)/epidemiologia , Complicações Pós-Operatórias/epidemiologia , Complicações Pós-Operatórias/prevenção & controle , Segurança do Paciente
6.
Eur Heart J ; 45(8): 586-597, 2024 Feb 21.
Artigo em Inglês | MEDLINE | ID: mdl-37624856

RESUMO

BACKGROUND AND AIMS: Benefit of tricuspid regurgitation (TR) correction and timing of intervention are unclear. This study aimed to compare survival rates after surgical or transcatheter intervention to conservative management according to a TR clinical stage as assessed using the TRI-SCORE. METHODS: A total of 2,413 patients with severe isolated functional TR were enrolled in TRIGISTRY (1217 conservatively managed, 551 isolated tricuspid valve surgery, and 645 transcatheter valve repair). The primary endpoint was survival at 2 years. RESULTS: The TRI-SCORE was low (≤3) in 32%, intermediate (4-5) in 33%, and high (≥6) in 35%. A successful correction was achieved in 97% and 65% of patients in the surgical and transcatheter groups, respectively. Survival rates decreased with the TRI-SCORE in the three treatment groups (all P < .0001). In the low TRI-SCORE category, survival rates were higher in the surgical and transcatheter groups than in the conservative management group (93%, 87%, and 79%, respectively, P = .0002). In the intermediate category, no significant difference between groups was observed overall (80%, 71%, and 71%, respectively, P = .13) but benefit of the intervention became significant when the analysis was restricted to patients with successful correction (80%, 81%, and 71%, respectively, P = .009). In the high TRI-SCORE category, survival was not different to conservative management in the surgical and successful repair group (61% and 68% vs 58%, P = .26 and P = .18 respectively). CONCLUSIONS: Survival progressively decreased with the TRI-SCORE irrespective of treatment modality. Compared to conservative management, an early and successful surgical or transcatheter intervention improved 2-year survival in patients at low and, to a lower extent, intermediate TRI-SCORE, while no benefit was observed in the high TRI-SCORE category.


Assuntos
Procedimentos Cirúrgicos Cardíacos , Implante de Prótese de Valva Cardíaca , Insuficiência da Valva Tricúspide , Humanos , Resultado do Tratamento , Cateterismo Cardíaco
7.
N Engl J Med ; 385(23): 2150-2160, 2021 12 02.
Artigo em Inglês | MEDLINE | ID: mdl-34449183

RESUMO

BACKGROUND: The role of direct oral anticoagulants as compared with vitamin K antagonists for atrial fibrillation after successful transcatheter aortic-valve replacement (TAVR) has not been well studied. METHODS: We conducted a multicenter, prospective, randomized, open-label, adjudicator-masked trial comparing edoxaban with vitamin K antagonists in patients with prevalent or incident atrial fibrillation as the indication for oral anticoagulation after successful TAVR. The primary efficacy outcome was a composite of adverse events consisting of death from any cause, myocardial infarction, ischemic stroke, systemic thromboembolism, valve thrombosis, or major bleeding. The primary safety outcome was major bleeding. On the basis of a hierarchical testing plan, the primary efficacy and safety outcomes were tested sequentially for noninferiority, with noninferiority of edoxaban established if the upper boundary of the 95% confidence interval for the hazard ratio did not exceed 1.38. Superiority testing of edoxaban for efficacy would follow if noninferiority and superiority were established for major bleeding. RESULTS: A total of 1426 patients were enrolled (713 in each group). The mean age of the patients was 82.1 years, and 47.5% of the patients were women. Almost all the patients had atrial fibrillation before TAVR. The rate of the composite primary efficacy outcome was 17.3 per 100 person-years in the edoxaban group and 16.5 per 100 person-years in the vitamin K antagonist group (hazard ratio, 1.05; 95% confidence interval [CI], 0.85 to 1.31; P = 0.01 for noninferiority). Rates of major bleeding were 9.7 per 100 person-years and 7.0 per 100 person-years, respectively (hazard ratio, 1.40; 95% CI, 1.03 to 1.91; P = 0.93 for noninferiority); the difference between groups was mainly due to more gastrointestinal bleeding with edoxaban. Rates of death from any cause or stroke were 10.0 per 100 person-years in the edoxaban group and 11.7 per 100 person-years in the vitamin K antagonist group (hazard ratio, 0.85; 95% CI, 0.66 to 1.11). CONCLUSIONS: In patients with mainly prevalent atrial fibrillation who underwent successful TAVR, edoxaban was noninferior to vitamin K antagonists as determined by a hazard ratio margin of 38% for a composite primary outcome of adverse clinical events. The incidence of major bleeding was higher with edoxaban than with vitamin K antagonists. (Funded by Daiichi Sankyo; ENVISAGE-TAVI AF ClinicalTrials.gov number, NCT02943785.).


Assuntos
4-Hidroxicumarinas/uso terapêutico , Fibrilação Atrial/tratamento farmacológico , Inibidores do Fator Xa/uso terapêutico , Piridinas/uso terapêutico , Tiazóis/uso terapêutico , Substituição da Valva Aórtica Transcateter , Vitamina K/antagonistas & inibidores , 4-Hidroxicumarinas/efeitos adversos , Idoso , Idoso de 80 Anos ou mais , Anticoagulantes/efeitos adversos , Anticoagulantes/uso terapêutico , Inibidores do Fator Xa/efeitos adversos , Feminino , Hemorragia Gastrointestinal/induzido quimicamente , Humanos , Análise de Intenção de Tratamento , Estimativa de Kaplan-Meier , Masculino , Mortalidade , Fenindiona/análogos & derivados , Fenindiona/uso terapêutico , Complicações Pós-Operatórias/prevenção & controle , Piridinas/efeitos adversos , Tiazóis/efeitos adversos , Tromboembolia/prevenção & controle , Substituição da Valva Aórtica Transcateter/efeitos adversos
8.
Am Heart J ; 271: 68-75, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38401649

RESUMO

BACKGROUND: Both transcatheter edge-to-edge repair (TEER) of mitral regurgitation or left atrial appendage closure (LAAC) require periprocedural anticoagulation with unfractionated heparin (UFH) that is administered either before or immediately after transseptal puncture (TSP). The optimal timing of UFH administration (before or after TSP) is unknown. The Strategy To Optimize PeriproCeduraL AnticOagulation in Structural Transseptal Interventions trial (STOP CLOT Trial) was designed to determine if early anticoagulation is effective in reducing ischemic complications without increasing the risk of periprocedural bleeding. METHODS: The STOP CLOT trial is a multicenter, prospective, double-blind, placebo-controlled, randomized trial. A total of 410 patients scheduled for TEER or LAAC will be randomized 1:1 either early UFH administration (iv. bolus of 100 units/kg UFH or placebo, given after obtaining femoral vein access and at least 5 minutes prior to the start of the TSP) or late UFH administration (iv. bolus of 100 units/kg UFH or placebo given immediately after TSP). Prespecified preliminary statistical analysis will be performed after complete follow-up of the first 196 randomized subjects. To ensure blinding, a study nurse responsible for randomization and UFH/placebo preparation is not involved in the care of the patients enrolled into the study. The primary study endpoint is a composite of (1) major adverse cardiac and cerebrovascular events (death, stroke, TIA, myocardial infarction, or peripheral embolization) within 30 days post-procedure, (2) intraprocedural fresh thrombus formation in the right or left atrium as assessed with periprocedural transesophageal echocardiography, or (3) occurrence of new ischemic lesions (diameter ≥4 mm) on brain magnetic resonance imaging performed 2 to 5 days after the procedure. The safety endpoint is the occurrence of moderate or severe bleeding complications during the index hospitalization. CONCLUSIONS: Protocols of periprocedural anticoagulation administration during structural interventions have never been tested in a randomized clinical trial. The Stop Clot trial may help reach consensus on the optimal timing of initiation of periprocedural anticoagulation. CLINICAL TRIALS REGISTRATION NUMBER: The study protocol is registered at ClinicalTrials.gov, identifier NCT05305612.


Assuntos
Anticoagulantes , Apêndice Atrial , Cateterismo Cardíaco , Heparina , Insuficiência da Valva Mitral , Feminino , Humanos , Masculino , Anticoagulantes/administração & dosagem , Apêndice Atrial/cirurgia , Apêndice Atrial/diagnóstico por imagem , Cateterismo Cardíaco/métodos , Método Duplo-Cego , Septos Cardíacos/cirurgia , Heparina/administração & dosagem , Insuficiência da Valva Mitral/cirurgia , Estudos Prospectivos , Estudos Multicêntricos como Assunto , Ensaios Clínicos Controlados Aleatórios como Assunto
9.
Am Heart J ; 270: 86-94, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38309610

RESUMO

BACKGROUND: Patients with severe aortic stenosis (AS) frequently present with concomitant obstructive coronary artery disease (CAD). In those, current guidelines recommend combined coronary artery bypass grafting (CABG) and surgical aortic valve replacement (SAVR) as the preferred treatment option, although this surgical approach is associated with a high rate of clinical events. Combined transcatheter aortic valve implantation (TAVI) and percutaneous coronary intervention (PCI) with or without FFR have evolved as a valid alternative for cardiac surgery in patients with AS and multivessel or advanced CAD. To date, no dedicated trial has prospectively evaluated the outcomes of a percutaneous versus surgical treatment for patients with both severe AS and CAD. AIMS: To investigate whether fractional-flow reserve (FFR)-guided PCI and TAVI is noninferior to combined CABG and SAVR for the treatment of severe AS and multivessel or advanced CAD. METHODS: The Transcatheter Valve and Vessels (TCW) trial (clinicaltrial.gov: NCT03424941) is a prospective, randomized, controlled, open label, international trial. Patients ≥ 70 years with severe AS and multivessel (≥ 2 vessels) or advanced CAD, deemed feasible by the heart team for both; a full percutaneous or surgical treatment, will be randomised in a 1:1 fashion to either FFR-guided PCI followed by TAVI (intervention arm) vs. CABG and SAVR (control arm). The primary endpoint is a patient-oriented composite of all-cause mortality, myocardial infarction, disabling stroke, unscheduled clinically-driven target vessel revascularization, valve reintervention, and life threatening or disabling bleeding at 1 year. The TCW trial is powered for noninferiority, and if met, superiority will be tested. Assuming a primary endpoint rate of 30% in the CABG-SAVR arm, with a significance level α of 5%, a noninferiority limit delta of 15% and a loss to follow-up of 2%, a total of 328 patients are needed to obtain a power of 90%. The primary endpoint analysis is performed on an intention-to-treat basis. SUMMARY: The TCW Trial is the first prospective randomized trial that will study if a less invasive percutaneous treatment for severe AS and concomitant advanced CAD (i.e., FFR-guided PCI-TAVI) is noninferior to the guidelines recommended approach (CABG-SAVR).


Assuntos
Estenose da Valva Aórtica , Doença da Artéria Coronariana , Reserva Fracionada de Fluxo Miocárdico , Intervenção Coronária Percutânea , Substituição da Valva Aórtica Transcateter , Humanos , Doença da Artéria Coronariana/complicações , Doença da Artéria Coronariana/diagnóstico , Doença da Artéria Coronariana/cirurgia , Valva Aórtica/cirurgia , Intervenção Coronária Percutânea/efeitos adversos , Estudos Prospectivos , Ponte de Artéria Coronária , Estenose da Valva Aórtica/complicações , Estenose da Valva Aórtica/diagnóstico , Estenose da Valva Aórtica/cirurgia , Resultado do Tratamento
10.
Am Heart J ; 2024 Jun 03.
Artigo em Inglês | MEDLINE | ID: mdl-38838970

RESUMO

BACKGROUND: The impact of prosthesis-patient mismatch (PPM) on major endpoints after transcatheter aortic valve replacement (TAVR) is controversial and the effects on progression of heart damage are poorly investigated. Therefore, our study aims to evaluate the prevalence and predictors of PPM in a "real world" cohort of patients at intermediate and low surgical risk, its impact on mortality and the clinical-echocardiographic progression of heart damage. METHODS: 963 patients who underwent TAVR procedure between 2017 and 2021, from the RECOVERY-TAVR international multicenter observational registry, were included in this analysis. Multiparametric echocardiographic data of these patients were analyzed at 1-year follow-up (FU). Clinical and echocardiographic features were stratified by presence of PPM and PPM severity, as per the most current international recommendations, using VARC-3 criteria. RESULTS: 18% of patients developed post-TAVR. PPM, and 7.7% of the whole cohort had severe PPM. At baseline, 50.3% of patients with PPM were male (vs 46.2% in the cohort without PPM, p=0.33), aged 82 (IQR 79-85y) years vs 82 (IQR 78-86 p=0.46), and 55.6% had Balloon-Expandable valves implanted (vs 46.8% of patients without PPM, p=0.04); they had smaller left ventricular outflow tract (LVOT) diameter (20 mm, IQR 19-21 vs 20 mm, IQR 20-22, p=0.02), reduced SVi (34.2 vs 38 ml/m2, p<0.01) and transaortic flow rate (190.6 vs 211 ml/s, p<0.01). At pre-discharge FU patients with PPM had more paravalvular aortic regurgitation (moderate-severe AR 15.8% vs 9.2%, p<0.01). At 1-year FU, maladaptive alterations of left ventricular parameters were found in patients with PPM, with a significant increase in end-systolic diameter (33 mm vs 28 mm, p=0.03) and a significant increase in left ventricle end systolic indexed volume in those with moderate and severe PPM (52 IQR 42-64 and 52, IQR 41-64 vs.44 IQR 35-59 in those without, p=0.02)). No evidence of a significant impact of PPM on overall (p=0.71) and CV (p=0.70) mortality was observed. Patients with moderate/severe PPM had worse NYHA functional class at 1 year (NYHA III-IV 13% vs 7.8%, p=0.03). Prosthesis size≤23 mm (OR 11.6, 1.68-80.1) was an independent predictor of PPM, while SVi (OR 0.87, 0.83-0.91, p<0.001) and LVOT diameter (OR 0.79, 0.65-0.95, p=0.01) had protective effect. CONCLUSIONS: PPM was observed in 18% of patients undergoing TAVR. Echocardiographic evaluations demonstrated a PPM-related pattern of early ventricular maladaptive alterations, possibly precursor to a reduction in cardiac function, associated with a significant deterioration in NYHA class at 1 year. These findings emphasize the importance of prevention of PPM of any grade in patients undergoing TAVR procedure, especially in populations at risk.

11.
RNA ; 28(9): 1263-1278, 2022 09.
Artigo em Inglês | MEDLINE | ID: mdl-35764396

RESUMO

Measurement of gene expression at the single-cell level has advanced the study of transcriptional regulation programs in healthy and disease states. In particular, single-cell approaches have shed light on the high level of transcriptional heterogeneity of individual cells, both at baseline and in response to experimental or environmental perturbations. We have developed a method for high-content imaging (HCI)-based quantification of relative changes in transcript abundance at the single-cell level in human primary immune cells and have validated its performance under multiple experimental conditions to demonstrate its general applicability. This method, named hcHCR, combines the sensitivity of the hybridization chain reaction (HCR) for the visualization of RNA in single cells, with the speed, scalability, and reproducibility of HCI. We first tested eight cell attachment substrates for short-term culture of primary human B cells, T cells, monocytes, or neutrophils. We then miniaturized HCR in 384-well format and documented the ability of the method to detect changes in transcript abundance at the single-cell level in thousands of cells for each experimental condition by HCI. Furthermore, we demonstrated the feasibility of multiplexing gene expression measurements by simultaneously assaying the abundance of three transcripts per cell at baseline and in response to an experimental stimulus. Finally, we tested the robustness of the assay to technical and biological variation. We anticipate that hcHCR will be suitable for low- to medium-throughput chemical or functional genomics screens in primary human cells, with the possibility of performing screens on cells obtained from patients with a specific disease.


Assuntos
Regulação da Expressão Gênica , Genômica , Humanos , RNA Mensageiro/genética , Reprodutibilidade dos Testes
12.
Artigo em Inglês | MEDLINE | ID: mdl-38736245

RESUMO

BACKGROUND: Malnutrition is associated with poor prognosis in several cardiovascular diseases; however, its role in patients with secondary mitral regurgitation (SMR) is poorly known. AIMS: To evaluate the impact of nutritional status, assessed using different scores, on clinical outcomes in patients with SMR undergoing transcatheter edge-to-edge repair (TEER) in a real-world setting. METHODS: A total of 658 patients with SMR and complete nutritional data were identified from the MIVNUT registry. Nutritional status has been assessed using controlling nutritional status index (CONUT), prognostic nutritional index (PNI), and geriatric nutritional risk index (GNRI) scores. Outcomes of interest were all-cause mortality and all-cause mortality or heart failure (HF) hospitalization. RESULTS: Any malnutrition grade was observed in 79.4%, 16.7%, and 47.9% of patients by using CONUT, PNI, and GNRI, respectively, while moderate to severe malnutrition was noted in 24.7%, 16.7%, and 25.6% of patients, respectively. At a median follow-up of 2.2 years, 212 patients (32.2%) died. Moderate-severe malnutrition was associated with a higher rate of all-cause mortality (HR: 2.46 [95% CI: 1.69-3.58], HR: 2.18 [95% CI: 1.46-3.26], HR: 1.97 [95% CI: 1.41-2.74] for CONUT, PNI, and GNRI scores, respectively). The combined secondary endpoint of all-cause mortality and HF rehospitalization occurred in 306 patients (46.5%). Patients with moderate-severe malnutrition had a higher risk of the composite endpoint (HR: 1.56 [95% CI: 1.20-2.28], HR: 1.55 [95% CI: 1.01-2.19], HR: 1.36 [95% CI: 1.02-1.80] for CONUT, PNI, and GNRI scores, respectively). After adjustment for multiple confounders, moderate-severe malnutrition remained independently associated with clinical outcomes. CONCLUSIONS: Moderate-severe malnutrition was common in patients with SMR undergoing TEER. It was independently associated with poor prognosis regardless of the different scores used.

13.
J Immunol ; 209(4): 772-782, 2022 08 15.
Artigo em Inglês | MEDLINE | ID: mdl-35858733

RESUMO

Neutrophils are the most abundant leukocytes in human blood and are essential components of innate immunity. Until recently, neutrophils were considered homogeneous and transcriptionally inactive cells, but both concepts are being challenged. Single-cell RNA sequencing (scRNA-seq) offers an unbiased view of cells along a continuum of transcriptional states. However, the use of scRNA-seq to characterize neutrophils has proven technically difficult, explaining in part the paucity of published single-cell data on neutrophils. We have found that modifications to the data analysis pipeline, rather than to the existing scRNA-seq chemistries, can significantly increase the detection of human neutrophils in scRNA-seq. We have then applied a modified pipeline to the study of human peripheral blood neutrophils. Our findings indicate that circulating human neutrophils are transcriptionally heterogeneous cells, which can be classified into one of four transcriptional clusters that are reproducible among healthy human subjects. We demonstrate that peripheral blood neutrophils shift from relatively immature (Nh0) cells, through a transitional phenotype (Nh1), into one of two end points defined by either relative transcriptional inactivity (Nh2) or high expression of type I IFN-inducible genes (Nh3). Transitions among states are characterized by the expression of specific transcription factors. By simultaneously measuring surface proteins and intracellular transcripts at the single-cell level, we show that these transcriptional subsets are independent of the canonical surface proteins that are commonly used to define and characterize human neutrophils. These findings provide a new view of human neutrophil heterogeneity, with potential implications for the characterization of neutrophils in health and disease.


Assuntos
Neutrófilos , Análise de Célula Única , Humanos , Análise de Sequência de RNA , Análise de Dados , Proteínas de Membrana
14.
Int Urogynecol J ; 35(5): 1021-1026, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38520516

RESUMO

INTRODUCTION AND HYPOTHESIS: Single-incision slings (SIS) have emerged as a less invasive alternative to conventional slings for stress urinary incontinence (SUI) treatment. However, long-term efficacy and safety results remain uncertain owing to a lack of studies. MATERIAL AND METHODS: A retrospective review of 155 patients treated with Altis® for SUI between February 2012 and June 2017, held in 2022, as a continuation of a prospective study in which all patients (197) were reviewed for 2 years after surgery (1, 6, 12, and 24 months). Preoperative demographic data, comorbidities, and pressure-flow studies were also recorded. Continence status and satisfaction rates were assessed using the International Consultation on Incontinence Questionnaire-short form (ICIQ-SF) and the Patient Global Impression of Improvement (PGI-I) respectively. The assessment in the 2022 retrospective review was performed via a telephone survey. RESULTS: Mean follow-up time after surgery was 85.3 months (82.5-88.1). In 2022, complete continence was present in 75.4% of the patients. The presence of urinary urgency conditioned the ICIQ-SF score (10.9 vs 1.7 points, p < 0.01), with the ICIQ-SF = 0 in 84.5% of the patients with no associated urgency. Satisfaction assessed by the PGI-I was high, with 84.6% of the patients showing improvement. De novo urgency was present in 37,9% of the patients by 2022. Urinary tract infections were the most frequent complication (9.7%), with only 5 documented cases of mesh erosion. CONCLUSIONS: Altis® SIS is a safe and effective device for SUI treatment, with satisfaction rates comparable with those of the conventional slings. Persistence or development of urinary urgency influences the results.


Assuntos
Satisfação do Paciente , Slings Suburetrais , Incontinência Urinária por Estresse , Humanos , Slings Suburetrais/efeitos adversos , Incontinência Urinária por Estresse/cirurgia , Feminino , Estudos Retrospectivos , Pessoa de Meia-Idade , Seguimentos , Resultado do Tratamento , Idoso , Fatores de Tempo , Adulto
15.
Eur Heart J ; 44(15): 1331-1339, 2023 04 17.
Artigo em Inglês | MEDLINE | ID: mdl-36883599

RESUMO

AIMS: Paravalvular regurgitation (PVR) after transcatheter aortic valve implantation (TAVI) is associated with increased morbidity and mortality. The effect of transcatheter interventions to treat PVR after the index TAVI was investigated. METHODS AND RESULTS: A registry of consecutive patients who underwent transcatheter intervention for ≥ moderate PVR after the index TAVI at 22 centers. The principal outcomes were residual aortic regurgitation (AR) and mortality at 1 year after PVR treatment. A total of 201 patients were identified: 87 (43%) underwent redo-TAVI, 79 (39%) plug closure, and 35 (18%) balloon valvuloplasty. Median TAVI-to-re-intervention time was 207 (35; 765) days. The failed valve was self-expanding in 129 (63.9%) patients. The most frequent devices utilized were a Sapien 3 valve for redo-TAVI (55, 64%), an AVP II as plug (33, 42%), and a True balloon for valvuloplasty (20, 56%). At 30 days, AR ≥ moderate persisted in 33 (17.4%) patients: 8 (9.9%) after redo-TAVI, 18 (25.9%) after plug, and 7 (21.9%) after valvuloplasty (P = 0.036). Overall mortality was 10 (5.0%) at 30 days and 29 (14.4%) at 1 year: 0, 8 (10.1%), and 2 (5.7%) at 30 days (P = 0.010) and 11 (12.6%), 14 (17.7%), and 4 (11.4%) at 1 year (P = 0.418), after redo-TAVI, plug, and valvuloplasty, respectively. Regardless of treatment strategy, patients in whom AR was reduced to ≤ mild had lower mortality at 1 year compared with those with AR persisting ≥ moderate [11 (8.0%) vs. 6 (21.4%); P = 0.007]. CONCLUSION: This study describes the efficacy of transcatheter treatments for PVR after TAVI. Patients in whom PVR was successfully reduced had better prognosis. The selection of patients and the optimal PVR treatment modality require further investigation.


Assuntos
Insuficiência da Valva Aórtica , Estenose da Valva Aórtica , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Humanos , Substituição da Valva Aórtica Transcateter/métodos , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Prognóstico , Resultado do Tratamento , Insuficiência da Valva Aórtica/etiologia , Insuficiência da Valva Aórtica/cirurgia
16.
Medicina (Kaunas) ; 60(2)2024 Jan 29.
Artigo em Inglês | MEDLINE | ID: mdl-38399519

RESUMO

Non-valvular atrial fibrillation (NVAF) is the most common cardiac arrhythmia in the general population, and its prevalence increases among patients with chronic kidney disease (CKD) undergoing hemodialysis. This population presents high risk of both hemorrhagic and thrombotic events, with little evidence regarding the use of oral anticoagulation treatment (OAT) and multiple complications arising from it; however, stroke prevention with percutaneous left atrial appendage closure (LAAC) is an alternative to be considered. We retrospectively describe the safety and efficacy of percutaneous LAAC in eight patients with NVAF and CKD on hemodialysis during a 12-month follow-up. The mean age was 78.8 years (range 64-86; SD ± 6.7), and seven patients were male. The mean CHA2DS2-VASC and HAS-BLED scores were high, 4.8 (SD ± 1.5) and 3.8 (SD ± 1.3), respectively. Seventy-five percent of the patients were referred for this intervention due to a history of major bleeding, with gastrointestinal bleeding being the most common type, while the remaining twenty-five percent of the patients were referred because of a high risk of bleeding. The percutaneous LAAC procedure was successfully completed in 100% of the patients, with complete exclusion of the appendage without complications or leaks exceeding 5 mm. There was one death not related to the procedure four days after the intervention. Among the other seven patients, no deaths, cardioembolic events or major bleeding were reported during the follow-up period. In our sample, percutaneous LAAC appears to be a safe and effective alternative to anticoagulation in patients with NVAF and CKD on hemodialysis.


Assuntos
Apêndice Atrial , Fibrilação Atrial , Falência Renal Crônica , Insuficiência Renal Crônica , Acidente Vascular Cerebral , Humanos , Masculino , Pessoa de Meia-Idade , Idoso , Idoso de 80 Anos ou mais , Feminino , Acidente Vascular Cerebral/etiologia , Acidente Vascular Cerebral/prevenção & controle , Acidente Vascular Cerebral/epidemiologia , Fibrilação Atrial/complicações , Fibrilação Atrial/cirurgia , Oclusão do Apêndice Atrial Esquerdo , Estudos Retrospectivos , Resultado do Tratamento , Hemorragia/complicações , Falência Renal Crônica/complicações , Falência Renal Crônica/terapia , Insuficiência Renal Crônica/complicações , Anticoagulantes/uso terapêutico , Diálise Renal/efeitos adversos , Apêndice Atrial/cirurgia
17.
Clin Infect Dis ; 76(6): 1003-1012, 2023 03 21.
Artigo em Inglês | MEDLINE | ID: mdl-36331961

RESUMO

BACKGROUND: Echocardiography is the primary imaging modality for diagnosis of infective endocarditis (IE) in prosthetic valve endocarditis (PVE) including IE after transcatheter aortic valve implantation (TAVI). This study aimed to evaluate the characteristics and clinical outcomes of patients with absent compared with evident echocardiographic signs of TAVI-IE. METHODS: Patients with definite TAVI-IE derived from the Infectious Endocarditis after TAVI International Registry were investigated comparing those with absent and evident echocardiographic signs of IE defined as vegetation, abscess, pseudo-aneurysm, intracardiac fistula, or valvular perforation or aneurysm. RESULTS: Among 578 patients, 87 (15.1%) and 491 (84.9%) had absent (IE-neg) and evident (IE-pos) echocardiographic signs of IE, respectively. IE-neg were more often treated via a transfemoral access with a self-expanding device and had higher rates of peri-interventional complications (eg, stroke, major vascular complications) during the TAVI procedure (P < .05 for all). IE-neg had higher rates of IE caused by Staphylococcus aureus (33.7% vs 23.2%; P = .038) and enterococci (37.2% vs 23.8%; P = .009) but lower rates of coagulase-negative staphylococci (4.7% vs 20.0%, P = .001). IE-neg was associated with the same dismal prognosis for in-hospital mortality in a multivariate binary regression analysis (odds ratio: 1.51; 95% confidence interval [CI]: .55-4.12) as well as a for 1-year mortality in Cox regression analysis (hazard ratio: 1.10; 95% CI: .67-1.80). CONCLUSIONS: Even with negative echocardiographic imaging, patients who have undergone TAVI and presenting with positive blood cultures and symptoms of infection are a high-risk patient group having a reasonable suspicion of IE and the need for an early treatment initiation.


Assuntos
Endocardite Bacteriana , Endocardite , Próteses Valvulares Cardíacas , Infecções Relacionadas à Prótese , Substituição da Valva Aórtica Transcateter , Humanos , Endocardite Bacteriana/diagnóstico por imagem , Endocardite Bacteriana/epidemiologia , Endocardite Bacteriana/etiologia , Substituição da Valva Aórtica Transcateter/efeitos adversos , Incidência , Fatores de Risco , Infecções Relacionadas à Prótese/diagnóstico por imagem , Infecções Relacionadas à Prótese/epidemiologia , Infecções Relacionadas à Prótese/etiologia , Endocardite/diagnóstico por imagem , Endocardite/epidemiologia , Ecocardiografia
18.
Am Heart J ; 264: 72-82, 2023 10.
Artigo em Inglês | MEDLINE | ID: mdl-37279839

RESUMO

BACKGROUND: Little data exist on the relationship between total stent length (TSL) and cardiovascular outcomes at very-long follow-up in patients with ST-elevation myocardial infarction (STEMI) in the 2nd generation drug-eluting stents (DES) era. AIM: To analyze the relationship between TSL and 10-year target-lesion failure (TLF) in STEMI patients treated with percutaneous coronary intervention enrolled in the EXAMINATION-EXTEND. METHODS: The EXAMINATION-EXTEND was an extended-follow-up study of the EXAMINATION trial, which randomized 1:1 STEMI patients to receive DES or bare metal stent (BMS). The primary endpoint was TLF, defined as a composite of target lesion revascularization (TLR), target vessel myocardial infarction (TVMI), or definite/probable stent thrombosis (ST). Relationship between stent length and TLF was evaluated in the whole study group in a multiple-adjusted Cox regression model with TSL as a quantitative variable. Subgroup analysis was also performed according to stent type, diameter, and overlap. RESULTS: A total of 1,489 patients with a median TSL of 23 mm (Q1-Q318-35 mm) were included. TSL was associated with TLF at 10 years (adjusted HR per 5 mm increase of 1.07; 95% CI, 1.01-1.14; P = .02). This effect was mainly driven by TLR and was consistent regardless of stent type, diameter, or overlap. There was no significant relationship between TSL and TV-MI or ST. CONCLUSIONS: In STEMI patients, there is a direct relationship between TSL implanted in the culprit vessel and the risk of TLF at 10 years, mainly driven by TLR. The use of DES did not modify this association.


Assuntos
Fármacos Cardiovasculares , Stents Farmacológicos , Intervenção Coronária Percutânea , Infarto do Miocárdio com Supradesnível do Segmento ST , Humanos , Infarto do Miocárdio com Supradesnível do Segmento ST/cirurgia , Seguimentos , Resultado do Tratamento , Stents , Desenho de Prótese
19.
Acta Neuropathol ; 145(1): 127-143, 2023 01.
Artigo em Inglês | MEDLINE | ID: mdl-36264506

RESUMO

DNAJ/HSP40 co-chaperones are integral to the chaperone network, bind client proteins and recruit them to HSP70 for folding. We performed exome sequencing on patients with a presumed hereditary muscle disease and no genetic diagnosis. This identified four individuals from three unrelated families carrying an unreported homozygous stop gain (c.856A > T; p.Lys286Ter), or homozygous missense variants (c.74G > A; p.Arg25Gln and c.785 T > C; p.Leu262Ser) in DNAJB4. Affected patients presented with axial rigidity and early respiratory failure requiring ventilator support between the 1st and 4th decade of life. Selective involvement of the semitendinosus and biceps femoris muscles was seen on MRI scans of the thigh. On biopsy, muscle was myopathic with angular fibers, protein inclusions and occasional rimmed vacuoles. DNAJB4 normally localizes to the Z-disc and was absent from muscle and fibroblasts of affected patients supporting a loss of function. Functional studies confirmed that the p.Lys286Ter and p.Leu262Ser mutant proteins are rapidly degraded in cells. In contrast, the p.Arg25Gln mutant protein is stable but failed to complement for DNAJB function in yeast, disaggregate client proteins or protect from heat shock-induced cell death consistent with its loss of function. DNAJB4 knockout mice had muscle weakness and fiber atrophy with prominent diaphragm involvement and kyphosis. DNAJB4 knockout muscle and myotubes had myofibrillar disorganization and accumulated Z-disc proteins and protein chaperones. These data demonstrate a novel chaperonopathy associated with DNAJB4 causing a myopathy with early respiratory failure. DNAJB4 loss of function variants may lead to the accumulation of DNAJB4 client proteins resulting in muscle dysfunction and degeneration.


Assuntos
Doenças Musculares , Insuficiência Respiratória , Animais , Camundongos , Mutação/genética , Doenças Musculares/diagnóstico por imagem , Doenças Musculares/genética , Chaperonas Moleculares/genética , Chaperonas Moleculares/metabolismo , Mutação de Sentido Incorreto , Insuficiência Respiratória/genética , Insuficiência Respiratória/complicações , Insuficiência Respiratória/patologia , Músculo Esquelético/patologia
20.
Catheter Cardiovasc Interv ; 102(3): 547-557, 2023 09.
Artigo em Inglês | MEDLINE | ID: mdl-37431253

RESUMO

Transcatheter aortic valve implantation (TAVI) is recommended for a growing range of patients with severe aortic stenosis in the European Society of Cardiology and European Association for Cardio-Thoracic Surgery (ESC/EACTS) 2021 Guidelines update. However, guideline implementation programs are needed to ensure the application of clinical recommendations which will favorably influence disease outcomes. An Expert Council was convened to identify whether cardiology services across Europe are set up to address the growing needs of patients with severe aortic stenosis for increased access to TAVI by identifying the key challenges faced in growing TAVI programs and mapping associated solutions. Wide variation exists across Europe in terms of TAVI availability and capacity to deliver the increased demand for TAVI in different countries. The recommendations of this Expert Council focus on the short-to-medium-term aspects where the most immediate, actionable impact can be achieved. The focus on improving procedural efficiency and optimizing the patient pathway via clinical practice and patient management demonstrates how to mitigate the current major issues of shortfall in catheterization laboratory, workforce, and bed capacity. Procedural efficiencies may be achieved through steps including streamlined patient assessment, the benchmarking of standards for minimalist procedures, standardized approaches around patient monitoring and conduction issues, and the implementation of nurse specialists and dedicated TAVI coordinators to manage organization, logistics, and early mobilization. Increased collaboration with wider stakeholders within institutions will support successful TAVI uptake and improve patient and economic outcomes. Further, increased education, collaboration, and partnership between cardiology centers will facilitate sharing of expertise and best clinical practice.


Assuntos
Estenose da Valva Aórtica , Substituição da Valva Aórtica Transcateter , Humanos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Resultado do Tratamento , Europa (Continente) , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA