Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
Langmuir ; 29(28): 9024-30, 2013 Jul 16.
Artigo em Inglês | MEDLINE | ID: mdl-23758672

RESUMO

Digital microfluidics, a technique for manipulation of droplets, is becoming increasingly important for the development of miniaturized platforms for laboratory processes. Despite the enthusiasm, droplet motion is frequently hindered by the desorption of proteins or other analytes to surfaces. Current approaches to minimize this unwanted surface fouling involve the addition of extra species to the droplet or its surroundings, which might be problematic depending on the droplet content. Here, a new strategy is introduced to move droplets containing cells and other analytes on solid substrates, without extra moieties; in particular, droplets with bovine serum albumin could be moved at a concentration 2000 times higher than previously reported (without additives). This capability is achieved by using a soot-based superamphiphobic surface combined with a new device geometry, which favors droplet rolling. Contrasting with electrowetting, wetting forces are not required for droplet motion.

2.
Lab Chip ; 8(5): 672-7, 2008 May.
Artigo em Inglês | MEDLINE | ID: mdl-18432335

RESUMO

Digital microfluidics has become a popular tool for biochemical and biomedical applications. However, its current format is restricted to actuation of droplets on a single plane. Here, we introduce a new method for fluid handling on flexible devices, which we have termed all-terrain droplet actuation (ATDA). We show that ATDA can be used to manipulate droplets across a wide range of geometries, including inclined, declined, vertical, twisted, and upside-down architectures. These new geometries enable flexible, straightforward integration of distinct physicochemical environments on monolithic devices. To illustrate this capacity, we developed temperature- and oxygen-sensitive colorimetric sensors, as well as an automated method for selective enrichment of DNA from a heterogeneous mixture. We anticipate that ATDA will be a useful new tool in the growing trend toward laboratory miniaturization.


Assuntos
DNA/química , Microfluídica/instrumentação , Microfluídica/métodos , Colorimetria/instrumentação , Colorimetria/métodos , Eletrodos , Desenho de Equipamento , Análise de Falha de Equipamento , Oxigênio/química , Propriedades de Superfície , Temperatura
3.
Lab Chip ; 6(11): 1415-23, 2006 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-17066164

RESUMO

Proteomics has emerged as the next great scientific challenge in the post-genome era. But even the most basic form of proteomics, proteome profiling, i.e., identifying all of the proteins expressed in a given sample, has proven to be a demanding task. The proteome presents unique analytical challenges, including significant molecular diversity, an extremely wide concentration range, and a tendency to adsorb to solid surfaces. Microfluidics has been touted as being a useful tool for developing new methods to solve complex analytical challenges, and, as such, seems a natural fit for application to proteome profiling. In this review, we summarize the recent progress in the field of microfluidics in four key areas related to this application: chemical processing, sample preconcentration and cleanup, chemical separations, and interfaces with mass spectrometry. We identify the bright spots and challenges for the marriage of microfluidics and proteomics, and speculate on the outlook for progress.


Assuntos
Procedimentos Analíticos em Microchip/tendências , Proteoma/análise , Proteômica/tendências , Animais , Humanos , Procedimentos Analíticos em Microchip/métodos , Microfluídica/instrumentação , Proteômica/instrumentação , Proteômica/métodos
4.
J Vis Exp ; (93): e52091, 2014 Nov 10.
Artigo em Inglês | MEDLINE | ID: mdl-25407533

RESUMO

Digital microfluidics (DMF), a technique for manipulation of droplets, is a promising alternative for the development of "lab-on-a-chip" platforms. Often, droplet motion relies on the wetting of a surface, directly associated with the application of an electric field; surface interactions, however, make motion dependent on droplet contents, limiting the breadth of applications of the technique. Some alternatives have been presented to minimize this dependence. However, they rely on the addition of extra chemical species to the droplet or its surroundings, which could potentially interact with droplet moieties. Addressing this challenge, our group recently developed Field-DW devices to allow the transport of cells and proteins in DMF, without extra additives. Here, the protocol for device fabrication and operation is provided, including the electronic interface for motion control. We also continue the studies with the devices, showing that multicellular, relatively large, model organisms can also be transported, arguably unaffected by the electric fields required for device operation.


Assuntos
Dispositivos Lab-On-A-Chip , Microfluídica/instrumentação , Animais , Caenorhabditis elegans , Eletrônica , Desenho de Equipamento , Microfluídica/métodos , Proteínas/química , Propriedades de Superfície , Molhabilidade
5.
J Vis Exp ; (33)2009 Nov 06.
Artigo em Inglês | MEDLINE | ID: mdl-19898419

RESUMO

Clinical proteomics has emerged as an important new discipline, promising the discovery of biomarkers that will be useful for early diagnosis and prognosis of disease. While clinical proteomic methods vary widely, a common characteristic is the need for (i) extraction of proteins from extremely heterogeneous fluids (i.e. serum, whole blood, etc.) and (ii) extensive biochemical processing prior to analysis. Here, we report a new digital microfluidics (DMF) based method integrating several processing steps used in clinical proteomics. This includes protein extraction, resolubilization, reduction, alkylation and enzymatic digestion. Digital microfluidics is a microscale fluid-handling technique in which nanoliter-microliter sized droplets are manipulated on an open surface. Droplets are positioned on top of an array of electrodes that are coated by a dielectric layer - when an electrical potential is applied to the droplet, charges accumulate on either side of the dielectric. The charges serve as electrostatic handles that can be used to control droplet position, and by biasing a sequence of electrodes in series, droplets can be made to dispense, move, merge, mix, and split on the surface. Therefore, DMF is a natural fit for carrying rapid, sequential, multistep, miniaturized automated biochemical assays. This represents a significant advance over conventional methods (relying on manual pipetting or robots), and has the potential to be a useful new tool in clinical proteomics.


Assuntos
Técnicas Analíticas Microfluídicas/métodos , Proteínas/análise , Proteômica/métodos , Animais , Automação Laboratorial/instrumentação , Automação Laboratorial/métodos , Bovinos , Técnicas Analíticas Microfluídicas/instrumentação , Proteômica/instrumentação , Soroalbumina Bovina/análise
6.
Electrophoresis ; 29(9): 1836-43, 2008 May.
Artigo em Inglês | MEDLINE | ID: mdl-18393343

RESUMO

We report a new method for fabricating nanospray ionization tips for MS, formed from glass substrates and the inert polymer, parylene-C. Using a single photolithography step, the emitters are formed contiguously with microchannels, such that no dead volumes are observed. In addition, because the devices are very thin (approximately 0.3 mm) and the tips are formed at rectangular corners, the Taylor cone volumes are small, which makes the method attractive for future integration with microfluidic separations. Device performance was demonstrated by evaluating diverse analytes, ranging from synthetic polymers, to peptides, to nucleic acids. For all analytes, performance was similar to that of conventional emitters (pulled-glass capillaries and the Agilent HPLC Chip) with the advantage of rapid, batch fabrication of identical devices.


Assuntos
Técnicas Analíticas Microfluídicas/instrumentação , Espectrometria de Massas por Ionização por Electrospray/instrumentação , Vidro , Nanotecnologia , Polímeros , Xilenos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA