Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 22
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
Assunto da revista
País de afiliação
Intervalo de ano de publicação
1.
Int Endod J ; 53(4): 506-512, 2020 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-31655019

RESUMO

AIM: To evaluate the influence of the metal artefact reduction (MAR) tool in the diagnosis of fractured instruments in root canals of extracted mandibular molars, with or without root canal fillings. METHODOLOGY: The root canals of 31 mandibular molars were divided into four groups: (i) the control group, without root fillings; (ii) the fracture group, without fillings and with fractured files; (iii) the fill group, with root filling; and (iv) the fill/fracture group, root filled and with fractured files. The following instruments were used as fractured endodontic instruments: stainless steel hand files, NiTi reciprocating files and NiTi rotary files. Each tooth was inserted in a dry mandible to obtain cone-beam computed tomography (CBCT) images using a CBCT OP300 3D Maxio (Instrumentarium Dental, Tuusula, Finland) and Picasso Trio (Vatech, Hwaseong, Republic of Korea), with and without application of the MAR tool. All images were evaluated by three radiologists for the presence or absence of fractured files on a 5-point scale. The diagnostic accuracy (area under ROC curve) was calculated. Image noise was measured in regions of trabecular and cortical bone and soft tissue. The comparison between the ROC curve values with the MAR tool enabled or disabled was performed using a t-test. A t-test was also employed for comparing image noise when the MAR tool was enabled and disabled. The significance level was set at 5%. RESULTS: The use of the MAR tool did not influence the diagnostic accuracy for identifying fractured endodontic instruments in root canals with and without fillings in both CBCT systems (P > 0.05), nor did it influence the image noise (P > 0.05). CONCLUSIONS: The MAR tool on these two devices did not increase the detection of fractured endodontic instruments and did not reduce image noise using extracted mandibular molars. Therefore, the MAR tool is not recommended for evaluation of fractured endodontic instruments in teeth with and without root fillings in mandibular molars.


Assuntos
Artefatos , Tomografia Computadorizada de Feixe Cônico , Cavidade Pulpar , Finlândia , República da Coreia , Obturação do Canal Radicular
2.
Int Endod J ; 52(6): 866-873, 2019 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-30585641

RESUMO

AIM: To assess the influence of artefacts, the metal artefact reduction (MAR) tool and kilovoltage (kVp) on the diagnosis of simulated external root resorption (ERR) in teeth close and distant to zirconium implants in cone beam computed tomography (CBCT) images. METHODOLOGY: Cavities (0.62 mm in diameter and 0.19 mm deep) were created in the apical thirds of 12 roots on the buccal, lingual, distal or mesial surface; ten roots served as controls. The roots were randomly positioned in the first and second right and left premolar sockets of a dry human mandible, and a zirconium implant was placed in the socket of the first right molar. A ProMax 3D unit varying kVp (70, 80, or 90 kVp) and with the MAR tool activated or not was used to obtain CBCT scans. Five examiners evaluated all images to determine the area under the receiver operating characteristic (ROC) curve, sensitivity and specificity. RESULTS: The ROC values and sensitivity were not affected by MAR or artefacts regardless of the distance to the implant (P > 0.05), whilst increasing kVp from 70 to 90 led to a significant increase in these values (P = 0.0202 and 0.0199, respectively). Specificity was not affected by the factors studied (P > 0.05). CONCLUSIONS: Amongst the factors studied, only kVp influenced the diagnosis of simulated external root resorption in CBCT images. Increasing kVp from 70 to 90 improved the accuracy in diagnosing the simulated lesions.


Assuntos
Reabsorção da Raiz , Artefatos , Tomografia Computadorizada de Feixe Cônico , Humanos , Mandíbula , Raiz Dentária , Zircônio
3.
Int Endod J ; 52(10): 1410-1416, 2019 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-31111507

RESUMO

AIM: To evaluate the association between endodontic technical errors and the root canal configuration (RCC) of human premolars, as well as their relationship with periapical lesions through cone-beam computed tomography (CBCT) images. METHODOLOGY: The sample consisted of CBCT scans belonging to 136 patients, totalling 152 root filled premolars (185 roots). CBCT images were evaluated by two oral radiologists. RCC was recorded according to Vertucci's classification, and the endodontic treatment quality was judged on the presence and type of technical endodontic errors (underfilling, overfilling, nonhomogeneous filling, nonfilled canal, fractured instruments, root deviation and absence of coronal restoration). In addition, the presence of periapical lesions associated with each RCC was recorded. Data were expressed by frequencies and percentages, and intraobserver agreement was calculated using the Kappa test. RESULTS: The most common RCC was type I (71%), followed by type IV (15%), type II (8%), type V (3%), type VI (1%) and type III (1%). Types VII and VIII were not observed in the sample. Underfilling was the most frequent endodontic technical error for most RCCs, except for types IV, V and 'other', whose most frequent error was a nonfilled canal. The presence of technical errors was greater with an increase in the proportion of the periapical lesions. The intraobserver agreement was excellent. CONCLUSIONS: There was an increase in the prevalence of endodontic technical errors and in the presence of periapical lesions as the anatomical complexity of the root canals increased. Underfilled and nonfilled canal were the most frequent endodontic technical errors.


Assuntos
Cavidade Pulpar , Tomografia Computadorizada de Feixe Cônico Espiral , Dente Pré-Molar , Tomografia Computadorizada de Feixe Cônico , Humanos , Tratamento do Canal Radicular
4.
Oral Dis ; 24(4): 628-637, 2018 May.
Artigo em Inglês | MEDLINE | ID: mdl-29224195

RESUMO

OBJECTIVE: To determine the prevalence of soft tissue calcifications in cone beam computed tomography (CBCT) scans with different fields of view (FOV) and to assess its relation with the clinical relevance of the CBCT findings. MATERIAL AND METHODS: One thousand CBCT scans were grouped according to FOV's size and region scanned (MX-FOV, maxilla; MD-FOV, mandible; and MM-FOV, maxilla/mandible) and evaluated for the presence of soft tissue calcifications. Laterality and length of the elongated styloid processes (ESP) were also assessed. RESULTS: Eight hundred and eighty-two soft tissue calcifications were detected in 626 (62.6%) patients. MM-FOV presented the highest prevalence (76.8%), followed by MD-FOV (60.6%) and MX-FOV (57.2%). ESP and tonsillolith were the most frequent calcifications. Calcifications requiring treatment or not and those in need of follow-up accounted for 6.9%, 92.7%, and 0.3% of cases, respectively. There was no association between calcifications and subjects' gender or age (p > .05). Most cases of ESP occurred bilaterally and were longer in males (p < .05). CONCLUSIONS: There is a high prevalence of soft tissue calcifications in CBCT, and ESP and tonsilloliths are the most common types in all evaluated FOVs. While most cases do not require treatment, we emphasize the importance of detailed CBCT assessment for its diagnosis.


Assuntos
Calcinose/diagnóstico por imagem , Calcinose/epidemiologia , Tomografia Computadorizada de Feixe Cônico , Tonsila Palatina/diagnóstico por imagem , Osso Temporal/diagnóstico por imagem , Adulto , Fatores Etários , Doenças das Artérias Carótidas/diagnóstico por imagem , Doenças das Artérias Carótidas/epidemiologia , Doenças das Cartilagens/diagnóstico por imagem , Doenças das Cartilagens/epidemiologia , Feminino , Humanos , Linfadenopatia/diagnóstico por imagem , Linfadenopatia/epidemiologia , Masculino , Mandíbula , Maxila , Pessoa de Meia-Idade , Prevalência , Doenças das Glândulas Salivares/diagnóstico por imagem , Doenças das Glândulas Salivares/epidemiologia , Fatores Sexuais , Dermatopatias/diagnóstico por imagem , Dermatopatias/epidemiologia
5.
Int Endod J ; 49(10): 973-9, 2016 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-26354080

RESUMO

AIM: To evaluate the influence of delayed scanning on images obtained with two PSPs digital systems and on the diagnostic accuracy of vertical root fracture (VRF) by means of objective and subjective analyses. METHODOLOGY: Forty single-rooted human teeth were divided into two groups, one without VRFs and another with VRFs induced by a universal testing machine. Two digital systems (VistaScan(®) and Express(®) ) were used to radiograph all teeth, and the resulting plates were scanned at four time-points: T0-immediately, T1-30 min, T2-2 h and T3-4 h after exposure. An aluminium (Al) wedge was used to evaluate the change in mean grey values as each scan was delayed. Three observers screened all images for VRFs, and one-fourth of the sample was revaluated after thirty days. Areas under the receiver operating characteristic (ROC) curve, sensitivity, specificity and accuracy values were compared by anova. RESULTS: Intra- and interobserver agreement ranged from moderate to substantial and fair to moderate, respectively. There was no significant difference amongst scan delays with regard to sensitivity, specificity and accuracy; however, there were significant differences in the area under the ROC curve, with the 4-h delayed scan being associated with lower values compared to the others (P = 0.019). As for objective analysis, there was a significant difference amongst all different scanning time-points for the two systems (P = 0.001), except between the 30-min and 2-h delayed scans in the VistaScan(®) system. CONCLUSION: Whilst delayed scanning caused changes to the density of images acquired with the systems studied, it did not seem to interfere with VRF diagnosis except when scanning was delayed for 4 h, which should therefore be avoided.


Assuntos
Radiografia Dentária Digital , Fraturas dos Dentes/diagnóstico por imagem , Raiz Dentária/diagnóstico por imagem , Humanos , Curva ROC , Sensibilidade e Especificidade , Fatores de Tempo
6.
Int Endod J ; 49(4): 386-92, 2016 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-25980480

RESUMO

AIM: To evaluate whether the type of display device affects the detection of vertical root fractures (VRFs) on digital radiographs in unfilled canals and canals with fibreglass posts. METHODOLOGY: Forty single-rooted human teeth were decoronated, and the root canals were prepared. The teeth were divided into 2 groups: controls (20 teeth) and with VRF (20 teeth). The VRFs were induced using an universal testing machine. Periapical radiographs of all teeth, with canal unfilled or with a fibreglass post, were obtained using the parallel technique in 3 directions (ortho-, mesio- and distoradial) on storage phosphor plates (VistaScan®). All images were evaluated and re-evaluated after 30 days by 3 examiners on a 5-point scale using 4 different devices (notebook display with full high definition resolution, desktop display with a standard resolution, 8-inch Android(™) tablet with high definition resolution and a 9.7-inch iPad® tablet with Retina resolution). Areas under ROC curves, sensitivity, specificity and accuracy values were compared by anova. RESULTS: The weighted kappa values for intra- and interobserver reproducibility were 0.55-0.88 and 0.31-0.65, respectively. There was a significant difference (P < 0.05) in relation to the area under the ROC curve, specificity and sensitivity when unfilled canals were compared with canals with a fibreglass post; however, no difference was observed for the different devices studied. CONCLUSIONS: The type of display device did not affect the detection of VRFs. Thus, the detection of VRFs can be performed using different screen sizes and resolutions.


Assuntos
Apresentação de Dados , Radiografia Dentária Digital/instrumentação , Fraturas dos Dentes/diagnóstico por imagem , Raiz Dentária/diagnóstico por imagem , Dente Pré-Molar/diagnóstico por imagem , Humanos , Técnicas In Vitro , Mandíbula/diagnóstico por imagem , Reprodutibilidade dos Testes , Preparo de Canal Radicular/métodos , Sensibilidade e Especificidade
7.
Int Endod J ; 48(9): 864-71, 2015 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-25251773

RESUMO

AIM: To evaluate (i) the accuracy of three intra-oral digital systems in detecting vertical root fractures (VRFs); and (ii) the influence of different intracanal conditions (without filling, filled with Gutta-percha and metal or fibreglass post). METHODOLOGY: Forty single-rooted human teeth were decoronated and the root canals prepared. VRFs were induced using a universal testing machine on 20 teeth. Radiographic images were obtained using the paralleling technique with three different horizontal angulations on conventional E/F film, two storage phosphor plates (Digora Optime and VistaScan) and one sensor system (SnapShot). All teeth were radiographed with all intracanal conditions tested. All images were evaluated by five examiners. After 30 days, 25% of the images were reviewed. Areas under ROC curves, sensitivity, specificity, accuracy, positive predictive and negative predictive values were compared by anova. RESULTS: The weighted kappa values for intra- and interobserver reproducibility were 0.48-0.74 and 0.57-0.66, respectively. The sensitivity revealed a significant difference between imaging modalities, with higher values for SnapShot (0.53) and VistaScan (0.46), followed by the film (0.41) and Digora (0.38). The area under the ROC curve for SnapShot (0.82) was greater than for the other systems in the teeth with a fibreglass post (VistaScan: 0.70; Digora: 0.64; film: 0.60). CONCLUSION: All systems gave a similar performance for detecting VRFs; all gave a good performance in the absence of intracanal materials, but performed less well in the presence of a metal post or Gutta-percha. In teeth with a fibreglass post, digital systems with higher resolution should be used.


Assuntos
Fraturas dos Dentes/diagnóstico por imagem , Raiz Dentária/diagnóstico por imagem , Raiz Dentária/lesões , Vidro , Guta-Percha/uso terapêutico , Humanos , Técnica para Retentor Intrarradicular , Radiografia Dentária Digital , Reprodutibilidade dos Testes , Materiais Restauradores do Canal Radicular/uso terapêutico , Obturação do Canal Radicular/métodos , Dente não Vital/diagnóstico por imagem
8.
Int Endod J ; 48(5): 428-34, 2015 May.
Artigo em Inglês | MEDLINE | ID: mdl-24893681

RESUMO

AIM: To compare the diagnostic accuracy of digital enhancement filters in the diagnosis of vertical root fractures. METHODOLOGY: The sample consisted of 40 single-rooted teeth randomly divided into two groups: experimental and control. Vertical root fractures were induced in the experimental group using a universal testing machine. All teeth were individually radiographed with three different horizontal angles using the Digora Optime(®) digital system. Three observers separately examined the original and filtered images (3D Emboss, Negative, Sharpen and Shadow). The area under Receiver Operating Characteristic curve values (Az) for each protocol were compared by one-way anova with post hoc Bonferroni test. The significance level was set at 5%. RESULTS: The highest Az value was obtained using the Sharpen filter, with significant differences from the original and other filtered images (P < 0.05). The 3D Emboss filter had the lowest Az value, which was significantly different from the other filtered images (P < 0.05). CONCLUSION: When using the Digora Optime(®) system, the 'Sharpen' filter is recommended to improve the radiographic detection of vertical root fractures.


Assuntos
Intensificação de Imagem Radiográfica/instrumentação , Radiografia Dentária Digital/métodos , Fraturas dos Dentes/diagnóstico por imagem , Raiz Dentária/diagnóstico por imagem , Humanos , Técnicas In Vitro , Interpretação de Imagem Radiográfica Assistida por Computador , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Raiz Dentária/lesões
9.
Oper Dent ; 48(3): E61-E69, 2023 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-37079916

RESUMO

OBJECTIVES: The purpose of this study was to correlate the translucency degree of varying resin composites with their radiopacity. METHODS AND MATERIALS: Twenty-four resin composites (conventional or bulk-fill) of various shades and opacities were selected from the following manufacturers: 3M ESPE (nanofilled), Ivoclar (nanohybrid), and FGM (microhybrid). Resin composite samples (n=5) were prepared (5-mm diameter × 1.5-mm thickness) for comparison using prepared samples of human dentin and enamel as controls. The translucency of each sample was measured using the translucent parameter (TP) method with a digital spectrophotometer (Vita Easyshade) and CIEL*a*b* color system over white and black backgrounds. The samples were also x-rayed using a photostimulable phosphor plate system for measurement of their radiopacity (in mmAl). All data were analyzed using one-way ANOVA and Student-Newman-Keuls (α=0.05); data for TP and radiopacity were correlated using the Spearman correlation test. RESULTS: Overall, the translucent shades and bulk-fill resin composites showed greater translucency than the other resins. While "body" and "enamel" shades demonstrated intermediate translucency to dentin and enamel, the "dentin" shades were more standardized, showing similar translucency to human dentin. All tested resin composites showed similar or greater radiopacity to human enamel, except the Empress Direct (Ivoclar) resin with Trans Opal shade, which was not radiopaque. Dentin and enamel showed radiopacity similar to 1 and 2 mmAl (millimeters of aluminum), respectively. CONCLUSIONS: The resin composites investigated in this study differed regarding their translucency degree and radiopacity level, without any positive relationship between the two properties.


Assuntos
Resinas Compostas , Materiais Dentários , Humanos , Cor , Teste de Materiais , Esmalte Dentário/diagnóstico por imagem
10.
Int Endod J ; 45(3): 234-9, 2012 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-22003884

RESUMO

AIM: To evaluate the diagnosis of simulated external root resorption in cone beam computed tomography (CBCT) images acquired with different voxel sizes, then reconstructed with the same voxel size. METHODOLOGY: Buccal, mesial and distal root surfaces of twenty single-rooted premolar teeth were evaluated for the presence or absence of simulated resorption defects. Images were obtained using a Classic i-CAT CBCT unit with two different voxel sizes (0.25 and 0.30 mm). Then all images were reconstructed to 0.25 mm voxel size. The McNemar's test was applied to evaluate the agreement between the two protocols (different voxel sizes/reconstruction parameters) with the gold standard (defects created in the root). Accuracy, sensitivity, specificity, positive and negative predictive values were calculated for each voxel and defect sizes. RESULTS: Better sensitivity and accuracy were obtained with 0.25 (0.25 mm) voxel size. Specificity, positive and negative predictive values were highest with the 0.25 (0.30 mm) voxel size. McNemar's test results revealed significant differences between the protocols with the gold standard (P < 0.0001). The results revealed that as the cavity size increased, sensitivity, accuracy, positive and negative predictive values also increased. When correlating the voxel size and root third, better sensitivity, accuracy, positive and negative predictive values were obtained in the middle third. CONCLUSIONS: In the diagnosis of simulated external root resorption with the Classic i-CAT CBCT unit, images acquired with 0.30 mm voxel size and reconstructed with 0.25 mm voxel size provided the best protocol with a lower radiation dose than the 0.25 mm voxel size.


Assuntos
Tomografia Computadorizada de Feixe Cônico/métodos , Processamento de Imagem Assistida por Computador/métodos , Reabsorção da Raiz/diagnóstico por imagem , Dente Pré-Molar/diagnóstico por imagem , Humanos , Variações Dependentes do Observador , Valor Preditivo dos Testes , Intensificação de Imagem Radiográfica/métodos , Reabsorção da Raiz/classificação , Sensibilidade e Especificidade , Ápice Dentário/diagnóstico por imagem , Colo do Dente/diagnóstico por imagem , Raiz Dentária/diagnóstico por imagem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA