RESUMO
BACKGROUND AND OBJECTIVES: Pain management is often suboptimal in individuals with dementia, and their family caregivers are tasked with supporting pain management despite limited preparation. The web-based PACE-app (PAin Control Enhancement) was designed to assist caregivers in managing pain for individuals with dementia. This study aimed to evaluate the usability of the PACE-app. RESEARCH DESIGN AND METHODS: A convergent parallel mixed-methods design was used to evaluate the PACE-app's usability with 16 family caregivers and 6 healthcare professionals. Quantitative data were collected using the Post-Study System Usability Questionnaire (PSSUQ), while qualitative data were gathered through guided app reviews and semi-structured interviews. Quantitative data were analyzed descriptively, and qualitative data were thematically coded. RESULTS: The PSSUQ results indicated that both family caregivers and healthcare professionals had a highly positive experience with the PACE-app: overall scores (2.01 vs. 1.68), system usefulness (1.76 vs. 1.68), information quality (1.98 vs. 1.80), interface quality (2.30 vs. 1.60), and satisfaction (2.00 vs. 1.60) were rated on a 1-7 scale (with lower scores indicating better usability). Qualitative findings supported these results, with participants endorsing the PACE-app's usefulness, ease of use, learnability, effective information presentation, aesthetics, clear layout, and overall satisfaction. Participants also provided valuable feedback for improving information quality (enhancing clarity) and interface quality (real-time coaching on pain management). DISCUSSION AND IMPLICATIONS: The study demonstrated favorable usability and strong satisfaction among family caregivers and healthcare professionals using the PACE-app. Incorporating participants' suggestions will guide enhancements to the app's information and interface, ensuring it better meets users' needs.
RESUMO
OBJECTIVES: To synthesize interventions designed to enhance resilience in family caregivers (FCs). METHODS: Electronic databases including PubMed, CINAHL, PsycINFO, and Scopus, were searched using index and keyword methods for articles published before January 2020. The review process followed the PRISMA review guidelines. Study quality was assessed using the Mixed Methods Appraisal Tool (MMAT). RESULTS: Six studies (seven articles) were included in this review. Quantitative evidence supports the benefits of psychoeducation, mindfulness-based intervention, and cognitive behavioral therapy (CBT)-based intervention but not expressive writing in improving in FCs' resilience. Four of the six included studies were randomized controlled trials. All included studies only met 40% to 60% of the MMAT criteria, indicating low to moderate levels of study quality. CONCLUSION: This review showed emerging evidence that psychoeducation, mindfulness-based intervention, and CBT-based intervention may improve caregiver resilience. However, it remains unclear which intervention and what dosage is the most effective in promoting FCs' resilience. Due to the small number of relevant studies and a low-to-moderate level of overall study quality, more rigorous clinical trials are needed to strengthen the current limited evidence base for FC resilience interventions.
RESUMO
Although pain management is integral to the caregiving role, there is a paucity of evidence synthesizing specific challenges family caregivers (FCs) face when managing pain for their care partners. This review comprehensively identified and summarized such challenges in the setting of advanced illnesses. Electronic databases (PubMed, CINAHL, PsycINFO, Scopus, and Health and Psychosocial Instruments) were searched using index and keyword methods for all articles published before April 2021. Fifty-five studies were included in this review. Most articles were published within the last 10 years (54%) in community settings, with home hospice care comprising the majority (50%). Most studies included patients with an advanced cancer diagnosis (84%), and 16% of the studies included patients with a noncancer diagnosis. Four major categories of challenges were identified: (1) caregiver-related issues (e.g., fears, beliefs, function), (2) caregivers' limited knowledge and skills in pain management (e.g., verbal and nonverbal pain assessment skills, pharmacological knowledge, documentation, safe management of medication), (3) communication challenges with health care providers, and (4) patient-related issues (e.g., inability to report pain). Many of these challenges have not been fully addressed in prior literature. Thus, this review provides a framework for needed future research to develop interventions that target FCs' specific challenges in providing pain management. The results also highlight a significant lack of research surrounding challenges faced by caregivers of care partners having a noncancer, dementia, or multimorbidity diagnosis.
Assuntos
Cuidadores , Manejo da Dor , Humanos , DorRESUMO
Neuropsychiatric disorders are becoming a major socioeconomic burden to modern society. In recent years, a dramatic expansion of tools has facilitated the study of the molecular basis of neuropsychiatric disorders. Molecular imaging has enabled the noninvasive characterization and quantification of biological processes at the cellular, tissue, and organism levels in intact living subjects. This technology has revolutionized the practice of medicine and has become critical to quality health care. New advances in research on molecular imaging hold promise for personalized medicine in neuropsychiatric disorders, with adjusted therapeutic doses, predictable responses, reduced adverse drug reactions, early diagnosis, and personal health planning. In this paper, we discuss the development of radiotracers for imaging dopaminergic, serotonergic, and noradrenergic systems and ß-amyloid plaques. We will underline the role of molecular imaging technologies in various neuropsychiatric disorders, describe their unique strengths and limitations, and suggest future directions in the diagnosis and management of neuropsychiatric disorders.
Assuntos
Transtornos Mentais/diagnóstico , Transtornos Mentais/terapia , Imagem Molecular/métodos , Doença de Alzheimer/diagnóstico , Doença de Alzheimer/terapia , Humanos , Transtornos do Humor/diagnóstico , Transtornos do Humor/terapia , Doença de Parkinson/diagnóstico , Doença de Parkinson/terapiaRESUMO
PURPOSE: 4-[(18)F]-ADAM is a potent serotonin transport imaging agent. We studied its toxicity in rats and radiation dosimetry in monkeys before human studies are undertaken. METHODS: Single and multiple-dosage toxicity studies were conducted in Sprague-Dawley rats. Male and female rats were injected intravenously with 4-F-ADAM as a single dose of 1,023.7 microg/kg (1,000 times the human dose) or as five consecutive daily doses of 102.37 microg/kg (100 times the human dose). PET/CT scans were performed in seven Formosa Rock monkeys (four males and three females) using a Siemens Biograph scanner. After injection of 4-[(18)F]-ADAM (182+/-8 MBq), a low dose CT scan and a series of eight whole-body PET scans were performed. Whole-body images were acquired in 3-D mode. Time-activity data of source organs were used to calculate the residence times and estimate the absorbed radiation dose using OLINDA/EXM software. RESULTS: In the rats neither the single dose nor the five daily doses of 4-F-ADAM produced overt adverse effects clinically. In the monkeys the radiation doses received by most organs ranged between 7.1 and 35.7 microGy/MBq, and the urinary bladder was considered to be the critical organ. The effective doses extrapolated to male and female adult humans were 17.4 and 21.8 microSv/MBq, respectively. CONCLUSION: Toxicity studies in Sprague-Dawley rats and radiation dosimetry studies in Formosa Rock monkeys suggested that 4-[(18)F]-ADAM is safe for use in human PET imaging studies.
Assuntos
Benzilaminas/farmacocinética , Benzilaminas/toxicidade , Radioisótopos de Flúor/química , Haplorrinos , Proteínas da Membrana Plasmática de Transporte de Serotonina/metabolismo , Adulto , Animais , Benzilaminas/química , Benzilaminas/metabolismo , Feminino , Humanos , Masculino , Doses de Radiação , Ensaio Radioligante , Radiometria , Ratos , Distribuição TecidualRESUMO
A 12-mer amino acid peptide SATTHYRLQAAN, denominated TK4, was isolated from a phage-display library with fibrosarcoma tumor-binding activity. In vivo biodistribution analysis of TK4-displaying phage showed a significant increased phage titer in implanted tumor up to 10-fold in comparison with normal tissues after systemic administration in mouse. Competition assay confirmed that the binding of TK4-phage to tumor cells depends on the TK4 peptide. Intravenous injection of (131)I-labeled synthetic TK4 peptide in mice showed a tumor retention of 3.3% and 2.7% ID/g at 1- and 4-hour postinjection, respectively. Tumor-to-muscle ratio was 1.1, 5.7, and 3.2 at 1-, 4-, and 24-hour, respectively, and tumors were imaged on a digital γ-camera at 4-hour postinjection. The present data suggest that TK4 holds promise as a lead structure for tumor targeting, and it could be further applied in the development of diagnostic or therapeutic agent.
Assuntos
Diagnóstico por Imagem/métodos , Sistemas de Liberação de Medicamentos/métodos , Fibrossarcoma/diagnóstico , Fibrossarcoma/terapia , Peptídeos/análise , Sequência de Aminoácidos , Animais , Linhagem Celular Tumoral , Feminino , Fibronectinas/farmacologia , Fibrossarcoma/metabolismo , Humanos , Camundongos , Dados de Sequência Molecular , Biblioteca de Peptídeos , Peptídeos/química , Ligação Proteica/efeitos dos fármacos , Distribuição Tecidual/efeitos dos fármacosRESUMO
CONTEXT: Family caregivers encounter many challenges when managing pain for their loved ones. There is a lack of clear recommendations on how to prepare caregivers in pain management. OBJECTIVES: To evaluate existing interventions that support family caregivers in providing pain management to patients with all disease types. METHODS: Four electronic databases were systematically searched (PubMed, Cumulative Index for Nursing Allied Health Literature, PsycINFO, and Scopus) using index and keyword methods for articles published before December 2019. The Mixed Methods Appraisal Tool was used to assess the quality. RESULTS: The search identified 6851 studies, and 25 studies met the inclusion criteria. Only two studies exclusively focused on noncancer populations (8%). Three types of interventions were identified in this review: educational interventions, cognitive-behavioral interventions, and technology-based interventions. Both educational and cognitive-behavioral interventions improved family caregiver and patient outcomes, but the content and intensity of these interventions in these studies varied widely, and there was a limited number of randomized clinical trials (68%). Hence, it is unclear what strategies are most effective to prepare family caregivers in pain management. Technology-based interventions were feasible to support family caregivers in providing pain management. CONCLUSION: Providing adequate pain management training can improve patient and family caregiver outcomes. However, the most effective interventions for family caregivers are still unclear. More rigorous and replicable clinical trials are needed to examine the effects of educational interventions, cognitive-behavioral interventions, and technology-based interventions. Also, more studies are needed in patients with a noncancer diagnosis or multimorbidity.
Assuntos
Cuidadores , Terapia Cognitivo-Comportamental , Humanos , DorRESUMO
The good clinical effectiveness of dopamine depleter and receptor antagonists on tics suggests dopaminergic hyperactivity in Tourette syndrome (TS). In this case-control study of 10 TS patients and 15 age-matched healthy controls, we evaluated (i) presynaptic and postsynaptic striatal dopaminergic function using [(99m)Tc]TRODAT-1/[(123)I]IBZM single photon emission computed tomography (SPECT) and (ii) correlations between dopamine transporter (DAT)/D2 receptor binding sites and tic severity scores. Patients 1-5 were pretreated with haloperidol and were drug free for at least 3 months before SPECT imaging. Patients 6-10 were drug-naïve. We found no significant difference in DAT and D2 receptor binding sites between TS patients and healthy controls nor any association between striatal DAT or D2 receptor binding sites and tic severity assessed using the Modified Rush Videotape Rating Scale. Our findings provided no direct evidence of abnormally available striatal DAT or dopamine D2 receptors in TS. However, functional abnormalities of the dopaminergic system, e.g., alterations in the synaptic release of endogenous dopamine, cannot be completely ruled out.
Assuntos
Benzamidas , Corpo Estriado/diagnóstico por imagem , Proteínas da Membrana Plasmática de Transporte de Dopamina/fisiologia , Processamento de Imagem Assistida por Computador , Radioisótopos do Iodo , Imageamento por Ressonância Magnética , Compostos de Organotecnécio , Pirrolidinas , Receptores de Dopamina D2/fisiologia , Tomografia Computadorizada de Emissão de Fóton Único , Síndrome de Tourette/diagnóstico por imagem , Tropanos , Adolescente , Adulto , Corpo Estriado/fisiopatologia , Feminino , Humanos , Masculino , Exame Neurológico , Receptores Pré-Sinápticos/fisiologia , Sinapses/fisiologia , Síndrome de Tourette/diagnóstico , Síndrome de Tourette/fisiopatologiaRESUMO
UNLABELLED: Noninvasive imaging in lung metastatic tumor models is used infrequently because of technical limitations in detecting metastases. We have previously used 2'-fluoro-2'-deoxy-5-iodo-1-beta-d-arabinofuranosyluracil labeled with (131)I ((131)I-FIAU) and demonstrated the applicability of noninvasive imaging for monitoring cancer gene therapy in an experimental animal model of herpes simplex virus type 1 thymidine kinase (HSV1-tk)-expressing tumor xenografts. We have now used the same animal model to effectively and noninvasively monitor the location, magnitude, and duration of therapeutic gene expression over time for the lung metastases model. METHODS: To improve the detectability of lung metastases, an experimental blood-borne lung metastases model in mice was established using intravenously administered HSV1-tk-expressing NG4TL4 fibrosarcoma cells (NG4TL4-TK) and simulated the clinical application of HSV1-tk plus ganciclovir (GCV) prodrug activation gene therapy. The efficacy of noninvasively monitoring the sites of development of lung metastatic lesions and their GCV-induced regression were assessed by SPECT with (131)I-FIAU. RESULTS: The results of this study showed that the lung metastases model of NG4TL4-TK cells could be successfully detected as early as 24 h after intravenous injection of tumor cells radiolabeled with (131)I-FIAU and also subsequently detected by extended monitoring with the intravenous injection of (131)I-FIAU on day 10. In mice treated with GCV, gamma-camera imaging demonstrated a significant growth inhibition of NG4TL4-TK cells of primary tumors and lung metastases on day 7 after initiating treatment. CONCLUSION: We conclude that this in vivo imaging approach will be useful for future studies of the lung metastases model and for the assessment of novel anticancer and antimetastatic therapies.
Assuntos
Ganciclovir/uso terapêutico , Terapia Genética/métodos , Neoplasias Pulmonares/diagnóstico por imagem , Neoplasias Pulmonares/diagnóstico , Animais , Técnicas de Transferência de Genes , Genes Reporter , Herpesvirus Humano 1/genética , Processamento de Imagem Assistida por Computador/métodos , Camundongos , Metástase Neoplásica , Cintilografia , Timidina Quinase/genética , Distribuição TecidualRESUMO
INTRODUCTION: [(123)I]-2-((2-((dimethylamino)methyl)phenyl)thio)-5-iodophenylamine ([(123)I]ADAM), a novel radiotracer, has promising application in the imaging of the serotonin transporter (SERT) in the human brain. In this study, the optimal scanning time for acquiring brain single photon emission computed tomography (SPECT) images was determined by performing dynamic SPECT studies at intervals from 0 to 6 h postinjection of [(123)I]ADAM. Additionally, radiation-absorbed doses were determined for three healthy human subjects using attenuation-corrected images. METHODS: Twelve subjects were randomized into one of three study groups as follows: whole-body distribution imaging (n=3), dynamic SPECT imaging (n=3) and brain SPECT imaging (n=6). The radiation-absorbed dose was calculated using MIRDOSE 3.0 software with attenuation-corrected data. The specific binding (SB) ratio of the brain stem was measured from dynamic SPECT images to determine the optimal scanning time. RESULTS: Dynamic SPECT images showed that the SB of the brain stem gradually increased to a maximum 4 h postinjection. Single photon emission computed tomography images at 4 h postinjection showed a high uptake of the radiotracer (SB) in the hypothalamus (1.40+/-0.12), brain stem (1.44+/-0.16), pons (1.13+/-0.14) and medial temporal lobe (0.59+/-0.10). The mean adult male value of effective dose was 3.37 x 10(-2) mSv/MBq with a 4.8-h urine-voiding interval. Initial high uptake in SERT-rich sites was demonstrated in the lung and brain. A prominent washout of the radiotracer from the lung further increased brain radioactivity that reached a peak value of 5.03% of injected dose 40 min postinjection. CONCLUSIONS: [(123)I]ADAM is a promising radiotracer for SPECT imaging of SERT in humans with acceptable dosimetry and high uptake in SERT-rich regions. Brain SPECT images taken within 4 h following injection show optimal levels of radiotracer uptake in known SERT sites. However, dynamic changes in lung SERT distribution must be carefully evaluated.
Assuntos
Encéfalo/diagnóstico por imagem , Encéfalo/metabolismo , Cinanserina/análogos & derivados , Proteínas da Membrana Plasmática de Transporte de Serotonina/metabolismo , Tomografia Computadorizada de Emissão de Fóton Único/métodos , Imagem Corporal Total/métodos , Adulto , Cinanserina/farmacocinética , Feminino , Humanos , Cinética , Masculino , Taxa de Depuração Metabólica , Especificidade de Órgãos , Compostos Radiofarmacêuticos/farmacocinética , Valores de Referência , Distribuição TecidualRESUMO
BACKGROUND: Histological methods are used to define the growth and response to various treatments of lung carcinoma in mice. The aim of the study was to evaluate a quantitative and 3D-tomographic microPET/microCT dual-image modality using 18F-fluorodeoxyglucose (FDG) to monitor the tumor progression in an experimental metastasis mouse model. MATERIALS AND METHODS: Six normal mice were subjected to FDG-microPET/microCT image scan to present the normal thorax morphology. Twenty-one 8-week-old male C57BL/6 mice were inoculated with 1 x 10(6) Lewis lung carcinoma cells (LLC1) through the lateral tail vein. FDG-microPET/microCT scans were performed on days 0, 5, 9, 13 and 18 (n=6) to monitor the growth of the tumor. MicroPET and microCT images were further used to monitor the metastasis of the lung carcinoma to the liver. Fifteen mice were sacrificed for biodistribution on days 0, 5, 9, 13 and 18 after the inoculation of lung carcinoma cells. RESULTS: The FDG-microPET/microCT dual-image modality showed that the growth of the tumor could be monitored longitudinally. The standard uptake value (SUV) of FDG increased from 0.63 +/- 0.05 on day 0 to 1.03 +/- 0.15 on day 18, reflecting the growth of the tumor in mice. The tumors located in the lung and liver could be clearly visualized by the fusion of microPET and microCT images, and further confirmed by whole-body autoradiography or H&E stain. CONCLUSION: By FDG-microPET, the increase in SUV provided an alternative for assessing the growth of a tumor in vivo. Our results suggest that the growth progression of lung carcinoma can be identified using the FDG-microPET/microCT dual-image modality longitudinally in mice.
Assuntos
Carcinoma Pulmonar de Lewis/diagnóstico por imagem , Fluordesoxiglucose F18 , Neoplasias Pulmonares/diagnóstico por imagem , Animais , Autorradiografia , Carcinoma Pulmonar de Lewis/metabolismo , Carcinoma Pulmonar de Lewis/secundário , Fluordesoxiglucose F18/farmacocinética , Neoplasias Hepáticas Experimentais/diagnóstico por imagem , Neoplasias Hepáticas Experimentais/metabolismo , Neoplasias Hepáticas Experimentais/secundário , Estudos Longitudinais , Neoplasias Pulmonares/metabolismo , Neoplasias Pulmonares/patologia , Masculino , Camundongos , Camundongos Endogâmicos C57BL , Metástase Neoplásica , Tomografia por Emissão de Pósitrons/métodos , Distribuição TecidualRESUMO
BACKGROUND: Clinical FDG/PET (2-deoxy-2-18F-fluoro-D-glucose/positron emission tomography) studies encounter difficulties in detecting early stage lung cancers. The aim of this study was to evaluate the ability of O-2-18F-fluoroethyl-L-tyrosine (FET) and FDG to differentiate between inflammation and lung carcinoma in mice. MATERIALS AND METHODS: Sixty-four C57BL/6 mice were inoculated with 2x10(6) LLC1 lung carcinoma cells in the right hind flank on day 0 and were then injected with 0.1 mL turpentine in the left thigh muscle on day 3. The progress of inflammation and tumor in mice was longitudinally monitored by FDG/microPET. The biodistribution study, pharmacokinetic evaluation and whole-body autoradiography of FET and FDG were performed on day 8 after tumor inoculation. RESULTS: The FDG uptakes in tumor and inflammatory lesions were 4.42-fold and 3.53-fold (n = 4) higher, respectively, than that in muscle at 90 min post-injection and the tumor-to-inflammation ratio was 1.25. For FET/microPET, the tumor uptake was 2.07-fold and 2.07-fold (n = 4) higher than those in muscle and inflammatory lesions at 90 min post-injection, respectively. The distribution half-life (t1/2,alpha) and the elimination half-life (t1/2,beta) of FET were 39 min and 205 min, respectively, in mice. CONCLUSION: FDG delineated both tumor and inflammation, while FET accumulated in tumor to a significantly higher extent. Our results demonstrated the potential of FET to distinguish epidermoid lung carcinoma from inflammatory lesions in mice.
Assuntos
Carcinoma Pulmonar de Lewis/diagnóstico por imagem , Carcinoma Pulmonar de Células não Pequenas/diagnóstico por imagem , Radioisótopos de Flúor , Fluordesoxiglucose F18 , Neoplasias Pulmonares/diagnóstico por imagem , Pneumonia/diagnóstico por imagem , Tirosina/análogos & derivados , Animais , Autorradiografia/métodos , Carcinoma Pulmonar de Lewis/metabolismo , Carcinoma Pulmonar de Células não Pequenas/metabolismo , Diagnóstico Diferencial , Fluordesoxiglucose F18/farmacocinética , Processamento de Imagem Assistida por Computador , Neoplasias Pulmonares/metabolismo , Masculino , Camundongos , Camundongos Endogâmicos C57BL , Pneumonia/induzido quimicamente , Pneumonia/metabolismo , Tomografia por Emissão de Pósitrons/métodos , Compostos Radiofarmacêuticos/farmacocinética , Terebintina , Tirosina/farmacocinéticaRESUMO
BACKGROUND: Dopamine transporter (DAT) neuroimaging radiotracers were developed to estimate dopamine neuronal loss in vivo in Parkinsons disease (PD). OBJECTIVE: To evaluate DAT density in vivo using [99mTc]-TRODAT-1 and single photon computerized tomography (SPECT) in a population of Brazilian PD. METHOD: Fifteen PD patients and 15 matched healthy controls scanned with [99mTc]-TRODAT-1 (INER-Taiwan) and SPECT. Estimates of striatum DAT density were calculated using binding potential (BP). Patients were assessed with PD scales. RESULTS: PD patients had significantly lower striatal DAT-BP (mean+/-SD) (0.38+/-0.12) compared to controls (BP=0.84+/-0.16; p<0.01). A 100% sensitivity and 100% specificity was obtained to discriminate PD cases from controls. Negative correlations between striatal DAT-BP and PD severity (rho=-0.7, p<0.001) and motor scales (rho=-0.80, p<0.001) were found. CONCLUSION: [99mTc]TRODAT-1 SPECTs scanning was able to discriminate PD patients from controls. The technique is a powerful instrument to measure DAT density that can be used in clinical and research settings in Brazil.
Assuntos
Proteínas da Membrana Plasmática de Transporte de Dopamina/análise , Compostos de Organotecnécio , Doença de Parkinson/diagnóstico por imagem , Compostos Radiofarmacêuticos , Tomografia Computadorizada de Emissão de Fóton Único/métodos , Tropanos , Adulto , Idoso , Estudos de Casos e Controles , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Doença de Parkinson/metabolismo , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Índice de Gravidade de DoençaRESUMO
This work is a pilot study of using a dual-head scanner in positron emission mammograph (PEM). A positron emission imager (PEImager) developed at our laboratory was used as a PEM prototype to obtain data. Dual-head projection imaging mode was used in the PEM study. An iterative algebraic reconstruction was employed to reconstruct projection data to obtain tomograms. A cylindrizal phantom filled with water was applied to simulate a breast and five hollow spheres (2 mm-10 mm diameters) filled with F-18 fluoride simulated tumors in the breast phantom. Preliminary data revealed that the locations and sizes of the hot spots in the breast phantom were determined from the reconstructed images. The ability to detect the tumor embedded in the radioactive water was evaluated. At a tumor-to-normal tissue ratio 20:1, a 3 mm tumor was detected; 5 mm and 10 mm tumors could be detected at the ratios of 10:1 and 5:1, respectively.
RESUMO
UNLABELLED: Distant metastasis is an important issue for nasopharyngeal carcinoma (NPC). The potential value of PET using 18F-FDG has not been well defined. This prospective study investigated the impact of 18F-FDG PET in NPC patients with stage M0 disease. METHODS: From April 2001 to June 2003, 140 NPC patients (118 primary and 22 primary recurrent) with stage M0 (negative results from chest radiography, liver sonography, and whole-body bone scanning) underwent 18F-FDG PET to check for distant metastases. Confirmatory MRI or CT was performed if any abnormal 18F-FDG uptake was found at distant sites. The distant lesion was confirmed pathologically, if feasible, and was followed up clinically and with imaging for at least 6 mo. RESULTS: 18F-FDG PET detected 26 true-positive metastatic sites in 18 (12.9%) of the 140 patients, among whom 14 had primary and 4 had recurrent tumors. The patient-based sensitivity and specificity of 18F-FDG PET for distant metastases were 100% and 86.9%, respectively. Mediastinal lymph nodes (n = 8) were the most common sites, followed by lung, liver, and bone (n = 5 each) and by other lymph nodes (n = 3). In patients with primary tumors, advanced nodal status (N2-3) was a statistically significant variable associated with development of distant metastases (P = 0.044). For recurrent NPC, neither age, sex, initial tumor stage, grade of differentiation, nor nodal stage showed a statistically significant difference between patients with and patients without distant metastases. CONCLUSION: 18F-FDG PET is valuable in avoiding aggressive locoregional radiotherapy in some NPC patients by the revelation of occult distant metastases, especially in patients with primary disease at a nodal stage of N2-3.
Assuntos
Carcinoma de Células Escamosas/diagnóstico por imagem , Carcinoma de Células Escamosas/patologia , Fluordesoxiglucose F18 , Neoplasias Nasofaríngeas/diagnóstico por imagem , Neoplasias Nasofaríngeas/patologia , Recidiva Local de Neoplasia/diagnóstico por imagem , Recidiva Local de Neoplasia/patologia , Tomografia por Emissão de Pósitrons/métodos , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Carcinoma de Células Escamosas/secundário , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Neoplasias Nasofaríngeas/secundário , Estadiamento de Neoplasias/métodos , Compostos Radiofarmacêuticos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Índice de Gravidade de Doença , Método Simples-Cego , Contagem Corporal Total/métodosRESUMO
Micro positron emission tomography (PET) and micro single-photon emission computed tomography (SPECT), used for imaging small animals, have become essential tools in developing new pharmaceuticals and can be used, among other things, to test new therapeutic approaches in animal models of human disease, as well as to image gene expression. These imaging techniques can be used noninvasively in both detection and quantification. However, functional images provide little information on the structure of tissues and organs, which makes the localization of lesions difficult. Image fusion techniques can be exploited to map the functional images to structural images, such as X-ray computed tomography (CT), to support target identification and to facilitate the interpretation of PET or SPECT studies. Furthermore, the mapping of two functional images of SPECT and PET on a structural CT image can be beneficial for those in vivo studies that require two biological processes to be monitored simultaneously. This paper proposes an automated method for registering PET, CT, and SPECT images for small animals. A calibration phantom and a holder were used to determine the relationship among three-dimensional fields of view of various modalities. The holder was arranged in fixed positions on the couches of the scanners, and the spatial transformation matrix between the modalities was held unchanged. As long as objects were scanned together with the holder, the predetermined matrix could register the acquired tomograms from different modalities, independently of the imaged objects. In this work, the PET scan was performed by Concorde's microPET R4 scanner, and the SPECT and CT data were obtained using the Gamma Medica's X-SPECT/CT system. Fusion studies on phantoms and animals have been successfully performed using this method. For microPET-CT fusion, the maximum registration errors were 0.21 mm +/- 0.14 mm, 0.26 mm +/- 0.14 mm, and 0.45 mm +/- 0.34 mm in the X (right-left), Y (upper lower), and Z (rostral-caudal) directions, respectively; for the microPET-SPECT fusion, they were 0.24 mm +/- 0.14 mm, 0.28 mm +/- 0.15 mm, and 0.54 mm +/- 0.35 mm in the X, Y, and Z directions, respectively. The results indicate that this simple method can be used in routine fusion studies.
Assuntos
Inteligência Artificial , Aumento da Imagem/métodos , Interpretação de Imagem Assistida por Computador/métodos , Imageamento Tridimensional/métodos , Técnica de Subtração , Tomografia Computadorizada de Emissão/métodos , Tomografia Computadorizada por Raios X/métodos , Algoritmos , Animais , Aumento da Imagem/instrumentação , Interpretação de Imagem Assistida por Computador/instrumentação , Imageamento Tridimensional/instrumentação , Masculino , Camundongos , Camundongos Endogâmicos C57BL , Reconhecimento Automatizado de Padrão/métodos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Tomografia Computadorizada de Emissão/instrumentação , Contagem Corporal Total/instrumentação , Contagem Corporal Total/métodosRESUMO
The maximum likelihood expectation maximization (MLEM) algorithm has several advantages over the conventional filtered back-projection (FBP) for image reconstruction. However, the slow convergence and the high computational cost for its practical implementation have limited its clinical applications. This study proposes the incorporation of a thresholding technique in both the MLEM and ordered subsets EM (OSEM) algorithm to accelerate convergence. The threshold is set to c*m, where m is the mean pixel value of the whole image. The reconstruction time is proportional to the total number of pixels, so a thresholding technique that nullifies the value of a pixel if it falls below a threshold, can effectively remove the non-active pixels and substantially accelerate reconstruction. Preliminary tests on simulated PET data reveal that the thresholding technique accelerates the convergence rate and reduce error in the reconstructed image. The reconstruction performance improves with the increase of the threshold level and the MSE reaches minimum for c value equals to about 1.
Assuntos
Algoritmos , Processamento de Imagem Assistida por Computador/estatística & dados numéricos , Funções Verossimilhança , Humanos , Processamento de Imagem Assistida por Computador/métodos , TaiwanRESUMO
UNLABELLED: Imaging of serotonin transporter (SERT) in the central nervous system may provide an important tool to evaluate some psychiatric disorders. Recently, a novel (123)I-labeled radiotracer, 2-((2-((dimethylamino)methyl)phenyl)thio)-5-iodophenylamine ((123)I-ADAM), has been developed that exhibited a high selectivity for SERT. The aim of this study was to characterize the biodistribution and specificity of (123)I-ADAM to SERT using quantitative autoradiography in both control and neurotoxin-treated animals. METHODS: (123)I-ADAM (74 MBq) was injected intravenously into the mice to access its biodistribution in the brain via quantitative autoradiography. Further, rats with serotonin depleted by intraperitoneal injection of p-chloroamphetamine (PCA) were used to evaluate the specificity of (123)I-ADAM to SERT. The levels of biogenic amines were then measured and correlated with quantitative (123)I-ADAM labeling in control and PCA-treated rat brains. RESULTS: The autoradiographic results showed that (123)I-ADAM accumulated in SERT-rich brain areas after systemic injection, including the globus pallidus, thalamus, hypothalamus, substantia nigra, interpeduncular nucleus, amygdala, and raphe nucleus. The dorsal raphe nucleus had the highest initial uptake with a peak specific binding ratio (i.e., [target - cerebellum]/cerebellum) at 120 min after injection. (123)I-ADAM uptake was dramatically decreased in the hippocampus, thalamus, amygdala, geniculate nuclei, hypothalamus, raphe nucleus, and substantia nigra in PCA-lesioned rats. The decrement in radioactivity was more prominent at higher dosages of PCA and was in parallel with the changes in amounts of serotonin and 5-hydroxyindoleacetic acid in the prefrontal cortex. CONCLUSION: This study demonstrates that regional distribution of (123)I-ADAM radioactivity is similar to the SERT localization in both rat and mouse brains. We also validated that destruction on central serotonergic neurons after PCA treatment inhibits the uptake of (123)I-ADAM in serotonin-rich brain regions. High specific binding to SERT in vivo makes (123)I-ADAM an appropriate radiotracer for solitary studies of serotonin functions in living humans.
Assuntos
Autorradiografia/métodos , Encéfalo/diagnóstico por imagem , Encéfalo/metabolismo , Proteínas de Transporte/metabolismo , Cinanserina/análogos & derivados , Cinanserina/farmacocinética , Radioisótopos do Iodo/farmacocinética , Glicoproteínas de Membrana/metabolismo , Proteínas de Membrana Transportadoras , Proteínas do Tecido Nervoso , Animais , Sítios de Ligação , Aminas Biogênicas/metabolismo , Encéfalo/efeitos dos fármacos , Masculino , Taxa de Depuração Metabólica/efeitos dos fármacos , Camundongos , Camundongos Endogâmicos ICR , Ligação Proteica , Cintilografia , Compostos Radiofarmacêuticos/farmacocinética , Ratos , Proteínas da Membrana Plasmática de Transporte de Serotonina , Distribuição Tecidual/efeitos dos fármacos , p-Cloroanfetamina/farmacologiaRESUMO
UNLABELLED: It has been reported that 18F-FDG PET is highly sensitive for the detection of recurrent head-and-neck cancer. The objective of our prospective study was to validate the ability of this technique to detect the presence of tumors in primary, nodal, and distant sites as well as to assess its overall clinical usefulness in patients with questionable MRI findings for residual or recurrent nasopharyngeal carcinoma (NPC). METHODS: From January 2002 to October 2003, a group of 37 NPC patients whose postradiation follow-up MRI examination showed questionable residual or recurrent disease was assessed with 18F-FDG PET. 18F-FDG PET was interpreted visually. Disease at primary, nodal, and distant sites was assessed. The final diagnosis was confirmed histopathologically or with clinical and imaging follow-up of at least 6 mo. RESULTS: Our results showed that the sensitivity and specificity of 18F-FDG PET for the detection of recurrent NPC were 91.6% and 76.0%, respectively, at the primary site; 90.0% and 88.9%, respectively, at nodal sites; and 100% and 90.6%, respectively, at distant sites. The overall sensitivity and specificity were 89.5% and 55.6%, respectively. Among the 37 patients, 18F-FDG PET added significant information to the MRI findings in 18, including offering true-negative findings in 10, revealing unexpected small metastatic adenopathy in 3, and disclosing distant metastatic foci in 5. CONCLUSION: 18F-FDG PET is highly sensitive and moderately specific for the detection of recurrent NPC in patients with questionable MRI findings. Overall, 18F-FDG PET appears to add significant information to MRI findings in about half of the NPC patients whose MRI examination shows questionable tumor recurrence.
Assuntos
Carcinoma/diagnóstico por imagem , Carcinoma/secundário , Fluordesoxiglucose F18 , Imageamento por Ressonância Magnética/métodos , Neoplasias Nasofaríngeas/diagnóstico por imagem , Recidiva Local de Neoplasia/diagnóstico por imagem , Tomografia por Emissão de Pósitrons/métodos , Adolescente , Adulto , Idoso , Carcinoma/diagnóstico , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Neoplasias Nasofaríngeas/diagnóstico , Recidiva Local de Neoplasia/diagnóstico , Compostos Radiofarmacêuticos , Reprodutibilidade dos Testes , Sensibilidade e EspecificidadeRESUMO
UNLABELLED: PET with 18F-FDG has shown its potential in cervical cancer. For maximizing the benefits of this new imaging technology, we aimed to define the prognostic features of recurrent cervical cancer patients for selecting appropriate candidates using 18F-FDG PET. METHODS: Patients enrolled were from 2 independent prospective studies investigating the role of 18F-FDG PET in cervical cancer patients after definitive treatment with documented failure (CTRP-018) or unexplained elevated tumor marker serum levels (CTRP-016) and proven relapse after PET. A total of 55 eligible patients received PET and CT or MRI. Lesion status was determined from pathologic results or clinical follow-up. The benefits calculated were based on treatment that was modified because of the PET findings. The Cox proportional hazards ratio (HR) was used to select independent prognostic covariates. RESULTS: Thirty-six (65.5%) patients had treatment that was modified due to PET. Primary radiation (HR = 14.62; 95% confidence interval [CI] = 2.74-77.92), squamous cell carcinoma antigen (SCC-Ag) > or = 4 ng/mL (HR = 5.82; 95% CI = 1.53-22.04), and presence of symptoms (HR = 6.24; 95% CI = 1.99-19.61) at recurrence were significant factors associated with poor survival. A scoring system using these covariates defined 3 distinct prognostic groups: score < or = 1 (HR = 1.00); score = 2 (HR = 6.91; 95% CI = 1.49-32.14); and score = 3 (HR = 60.46; 95% CI = 9.68-378.09) (P < 0.0001). CONCLUSION: Using this risk score, 18F-FDG PET may offer maximal benefits by selecting appropriate recurrent cervical cancer patients for salvage therapy with precise restaging information.