Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 336
Filtrar
Mais filtros

Intervalo de ano de publicação
1.
Hum Reprod ; 38(4): 549-559, 2023 04 03.
Artigo em Inglês | MEDLINE | ID: mdl-36762880

RESUMO

STUDY QUESTION: Can early pregnancies be accurately and cost-effectively diagnosed and managed using a new medical computerized tool? SUMMARY ANSWER: Compared to the standard clinical approach, retrospective implementation of the new medical software in a gynaecological emergency unit was correlated with more accurate diagnosis and more cost-effective management. WHAT IS KNOWN ALREADY: Early pregnancy complications are responsible for a large percentage of consultations, mostly in emergency units, with guidelines becoming complex and poorly known/misunderstood by practitioners. STUDY DESIGN, SIZE, DURATION: A total of 780 gynaecological emergency consultations (446 patients), recorded between November 2018 and June 2019 in a tertiary university hospital, were retrospectively encoded in a new medical computerized tool. The inclusion criteria were a positive hCG test result, ultrasonographical visualization of gestational sac, and/or embryo corresponding to a gestational age of 14 weeks or less. Diagnosis and management suggested by the new computerized tool are named eDiagnoses, while those provided by a gynaecologist member of the emergency department staff are called medDiagnoses. PARTICIPANTS/MATERIALS, SETTING, METHODS: Usability was the primary endpoint, with accuracy and cost reduction, respectively, as secondary and tertiary endpoints. Identical eDiagnoses/medDiagnoses were considered as accurate. During follow-up visits, if the updated eDiagnoses and medDiagnoses became both identical to a previously discrepant eDiagnosis or medDiagnosis, this previous eDiagnosis or medDiagnosis was also considered as correct. Four double-blinded experts reviewed persistent discrepancies, determining the accurate diagnoses. eDiagnoses/medDiagnoses accuracies were compared using McNemar's Chi square test, sensitivity, specificity, and predictive values. MAIN RESULTS AND THE ROLE OF CHANCE: Only 1 (0.1%) from 780 registered medical records lacked data for full encoding. Out of the 779 remaining consultations, 675 eDiagnoses were identical to the medDiagnoses (86.6%) and 104 were discrepant (13.4%). From these 104, 60 reached an agreement during follow-up consultations, with 59 medDiagnoses ultimately changing into the initial eDiagnoses (98%) and only one discrepant eDiagnosis turning later into the initial medDiagnosis (2%). Finally, 24 remained discrepant at all subsequent checks and 20 were not re-evaluated. Out of these 44, the majority of experts agreed on 38 eDiagnoses (86%) and 5 medDiagnoses (11%, including four twin pregnancies whose twinness was the only discrepancy). No majority was reached for one discrepant eDiagnosis/medDiagnosis (2%). In total, the accuracy of eDiagnoses was 99.1% (675 + 59 + 38 = 772 eDiagnoses out of 779), versus 87.4% (675 + 1 + 5 = 681) for medDiagnoses (P < 0.0001). Calculating all basic costs of extra consultations, extra-medications, extra-surgeries, and extra-hospitalizations induced by incorrect medDiagnoses versus eDiagnoses, the new medical computerized tool would have saved 3623.75 Euros per month. Retrospectively, the medical computerized tool was usable in almost all the recorded cases (99.9%), globally more accurate (99.1% versus 87.4%), and for all diagnoses except twinning reports, and it was more cost-effective than the standard clinical approach. LIMITATIONS, REASONS FOR CAUTION: The retrospective study design is a limitation. Some observed improvements with the medical software could derive from the encoding by a rested and/or more experienced physician who had a better ultrasound interpretation. This software cannot replace clinical and ultrasonographical skills but may improve the compliance to published guidelines. WIDER IMPLICATIONS OF THE FINDINGS: This medical computerized tool is improving. A new version considers diagnosis and management of multiple pregnancies with their specificities (potentially multiple locations, chorioamnionicity). Prospective evaluations will be required. Further developmental steps are planned, including software incorporation into ultrasound devices and integration of previously published predictive/prognostic factors (e.g. serum progesterone, corpus luteum scoring). STUDY FUNDING/COMPETING INTEREST(S): No external funding was obtained for this study. F.B. and D.G. created the new medical software. TRIAL REGISTRATION NUMBER: NCT03993015.


Assuntos
Complicações na Gravidez , Feminino , Humanos , Lactente , Gravidez , Análise Custo-Benefício , Estudos Retrospectivos , Software , Ultrassonografia
2.
Arch Orthop Trauma Surg ; 142(12): 3659-3665, 2022 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-34043072

RESUMO

BACKGROUND: In recent literature, the increasing number of medical litigations, both in terms of the number of cases being filed and the substantive costs associated with lawsuits, has been described. This study aims to provide an overview of the profile of litigation for orthopedic and trauma surgery to describe the differences and the development of the number of cases over time. PATIENTS AND MATERIALS: A retrospective review of all litigations between 2000 and 2017 was conducted using the institutional legal database. The causes of litigation were documented and classified into seven major categories. In addition to plaintiff characteristics, the litigation outcomes and the differences between emergency and elective surgery were analyzed. RESULTS: A total of 230 cases were evaluated. The mean age of the plaintiffs was 44.6 ± 20.1 years, and 56.8% were female. The main reasons for litigation were claimed inappropriate management (46.1%), misdiagnosis (22.6), and poor nursing care (8.3%). Significantly more litigations were filed against surgeons of the orthopedic subspecialty compared with trauma surgeons (78%; p ≤ 0.0001). There were significantly fewer litigations per 1000 cases filed overall in 2009-2017 (65% less; p = 0.003) than in 2000-2008. CONCLUSION: Our results could not confirm the often-stated trend of having more litigations against orthopedic and trauma surgeons. Although the absolute numbers increased, the number of litigations per 1000 patients treated declined. Patients who underwent elective surgery were more likely to file complaints than emergency patients.


Assuntos
Imperícia , Procedimentos Ortopédicos , Ortopedia , Cirurgiões , Humanos , Feminino , Adulto Jovem , Adulto , Pessoa de Meia-Idade , Masculino , Procedimentos Ortopédicos/efeitos adversos , Bases de Dados Factuais
3.
Appl Environ Microbiol ; 87(9)2021 04 13.
Artigo em Inglês | MEDLINE | ID: mdl-33608298

RESUMO

Biosurfactant production is a common trait in leaf surface-colonizing bacteria that has been associated with increased survival and movement on leaves. At the same time, the ability to degrade aliphatics is common in biosurfactant-producing leaf colonizers. Pseudomonads are common leaf colonizers and have been recognized for their ability to produce biosurfactants and degrade aliphatic compounds. In this study, we investigated the role of biosurfactants in four non-plant-pathogenic Pseudomonas strains by performing a series of experiments to characterize their surfactant properties and their role during leaf colonization and diesel degradation. The biosurfactants produced were identified using mass spectrometry. Two strains produced viscosin-like biosurfactants, and the other two produced massetolide A-like biosurfactants, which aligned with the phylogenetic relatedness between the strains. To further investigate the role of surfactant production, random Tn5 transposon mutagenesis was performed to generate knockout mutants. The knockout mutants were compared to their respective wild types with regard to their ability to colonize gnotobiotic Arabidopsis thaliana and to degrade diesel or dodecane. It was not possible to detect negative effects during plant colonization in direct competition or individual colonization experiments. When grown on diesel, knockout mutants grew significantly slower than their respective wild types. When grown on dodecane, knockout mutants were less impacted than during growth on diesel. By adding isolated wild-type biosurfactants, it was possible to complement the growth of the knockout mutants.IMPORTANCE Many leaf-colonizing bacteria produce surfactants and are able to degrade aliphatic compounds; however, whether surfactant production provides a competitive advantage during leaf colonization is unclear. Furthermore, it is unclear if leaf colonizers take advantage of the aliphatic compounds that constitute the leaf cuticle and cuticular waxes. Here, we tested the effect of surfactant production on leaf colonization, and we demonstrate that the lack of surfactant production decreases the ability to degrade aliphatic compounds. This indicates that leaf surface-dwelling, surfactant-producing bacteria contribute to degradation of environmental hydrocarbons and may be able to utilize leaf surface waxes. This has implications for plant-microbe interactions and future studies.


Assuntos
Arabidopsis/microbiologia , Gasolina , Folhas de Planta/microbiologia , Pseudomonas/metabolismo , Tensoativos/metabolismo , Alcanos/metabolismo , Biodegradação Ambiental , Mutagênese , Filogenia , Pseudomonas/genética , Pseudomonas/crescimento & desenvolvimento , RNA Ribossômico 16S , Tensoativos/química
4.
J Biol Regul Homeost Agents ; 34(6 Suppl. 3): 47-57, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-33412780

RESUMO

The systematic analysis of parameters impacting implant primary stability is difficult to achieve with human cadavers or animal models, particularly for complex trans-sinus procedures to determine the effects of cortical layers and bone engagement on implant stability before and after a simulated load in vitro. Solid rigid polyurethane blocks, partially intersected by an 8-mm-thick space, were created to imitate tri-cortical situations, the presence of the sinus cavity, and the posterior maxilla with different degrees of bone atrophy. Implants were inserted through the cavity at an angle of 30˚ (scenarios 1 and 2) to imitate the clinical protocol. Controls simulating uni-cortical anchorage and no sinus cavity were also included (controls 1 and 2). Four parameters were measured: peak insertion torque, insertion work, resistance to lateral bending loads and extraction torque. Scenarios 1 and 2 displayed similar peak insertion torque to control 2, where all three groups anchored equal amounts of bone surrogate. The distribution of surrogate bone in contact with trans-cavity implants influenced both extraction torque and the degree of lateral bending. Sufficient peak insertion torque can be attained with a trans-sinus tricortical implant anchorage providing sufficient apical and coronal bone is engaged.


Assuntos
Osso Cortical , Implantes Dentários , Humanos , Maxila/cirurgia , Poliuretanos , Próteses e Implantes , Torque
5.
Prenat Diagn ; 36(13): 1199-1205, 2016 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-27813120

RESUMO

OBJECTIVES: To determine the prognostic value of fetal Doppler and echocardiographic parameters for neonatal survival up to 30 days after laser coagulation in monochorionic pregnancies complicated by twin-twin transfusion syndrome (TTTS). METHODS: Fetal echocardiography and outcome data of consecutive cases of TTTS treated by laser were retrospectively reviewed. Hemodynamic and cardiac function parameters were collected before and after laser. RESULTS: Between February 2006 and January 2015, 106 fetoscopic laser were performed. The final analysis was limited to cases with ultrasound within 2 days before laser (n = 77) and 4 weeks after laser (n = 86). Overall neonatal survival rate was 64.9% (135/208) and 77.9% of pregnancies (81/104) had at least one baby alive. For the recipient twin, the preoperative predictors of neonatal survival were umbilical artery (UA) pulsatility index (PI), cerebro-placental PI ratio, UA end diastolic flow (EDF), ductus venosus a-wave, right ventricular myocardial performance index (RV-MPI) and CHOP score. The postoperative predictors of donor survival were donor RV-MPI and recipient UA EDF, umbilical vein pulsations, tricuspid regurgitation, cardiac hypertrophy and CHOP score. CONCLUSION: The hemodynamic predictors of postnatal survival after laser were preoperative signs of recipient cardiomyopathy and postoperative signs of cardiac overload in both twins. © 2016 John Wiley & Sons, Ltd.


Assuntos
Coração Fetal/diagnóstico por imagem , Transfusão Feto-Fetal/diagnóstico por imagem , Transfusão Feto-Fetal/cirurgia , Fotocoagulação a Laser , Gêmeos , Ultrassonografia Pré-Natal , Ecocardiografia , Feminino , Coração Fetal/fisiopatologia , Transfusão Feto-Fetal/mortalidade , Fetoscopia , Idade Gestacional , Humanos , Gravidez , Prognóstico , Fluxo Pulsátil , Estudos Retrospectivos , Resultado do Tratamento , Artérias Umbilicais/fisiopatologia
6.
Phys Rev Lett ; 113(18): 187001, 2014 Oct 31.
Artigo em Inglês | MEDLINE | ID: mdl-25396389

RESUMO

We investigate by angle-resolved photoemission the electronic structure of in situ grown tetragonal CuO, a synthetic quasi-two-dimensional edge-sharing cuprate. We show that, in spite of the very different nature of the copper oxide layers, with twice as many Cu in the CuO layers of tetragonal CuO as compared to the CuO(2) layers of the high-T(c) cuprates, the low-energy electronic excitations are surprisingly similar, with a Zhang-Rice singlet dispersing on weakly coupled cupratelike sublattices. This system should thus be considered as a member of the high-T(c) cuprate family, with, however, interesting differences due to the intralayer coupling between the cupratelike sublattices.

8.
Br J Cancer ; 109(7): 1821-8, 2013 Oct 01.
Artigo em Inglês | MEDLINE | ID: mdl-24002608

RESUMO

BACKGROUND: The prognosis of metastatic non-small cell lung cancer (NSCLC) is still poor. Activating epithelial growth factor receptor (EGFR) mutations are important genetic alterations with dramatic therapeutical implications. Up to now, in contrast to Asian populations only limited data on the prevalence of those mutations are available from patients with Caucasian and especially European ethnicity. METHODS: In this multicentre study, 1201 unselected NSCLC patients from Southern Germany were tested in the daily clinical routine for EGFR mutation status. RESULTS: Activating EGFR mutations were found in 9.8% of all tumours. Mutations in exons 18, 19 and 21 accounted for 4.2%, 61.9% and 33.1% of all mutations, respectively. Non-smokers had a significantly higher rate of EGFR mutations than smokers or ex-smokers (24.4% vs 4.2%; P<0.001). Non-lepidic-non-mucinous adenocarcinomas (G2) accounted for 45.5% of all activating EGFR mutations and 3.5% of all squamous cell carcinomas were tested positive. Thyroid transcription factor 1 protein expression was significantly associated with EGFR mutational status. CONCLUSION: These comprehensive data from clinical routine in Germany add to the knowledge of clinical and histopathological factors associated with EGFR mutational status in NSCLC.


Assuntos
Adenocarcinoma/genética , Carcinoma Pulmonar de Células não Pequenas/genética , Carcinoma de Células Escamosas/genética , Receptores ErbB/genética , Neoplasias Pulmonares/genética , Mutação , Idoso , Europa (Continente) , Feminino , Humanos , Masculino , Proteínas Nucleares/biossíntese , Fumar , Fator Nuclear 1 de Tireoide , Fatores de Transcrição/biossíntese
9.
Ultrasound Obstet Gynecol ; 41(1): 40-6, 2013 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-23023941

RESUMO

OBJECTIVES: To evaluate the feasibility of completing in one session a second-trimester ultrasound scan in obese pregnant women, to compare the quality of images obtained with those of non-obese women and to analyze factors that can improve the completion rate. METHODS: This prospective study, from 2009 to 2011, included all obese pregnant women (prepregnancy body mass index (BMI) > 30 kg/m2) who had an ultrasound examination at 20-24 weeks in our department, and a control group of pregnant women with normal BMI (20-24.9 kg/m2) who had the same examination. A single operator reviewed the standardized ultrasound images (three biometric and six to assess key anatomical features) required under French guidelines, to assess their presence, evaluate the quality of all images and score the quality of the six anatomical images. Each image was assessed according to between four and six criteria, each worth one point. We sought excellent quality, defined as the frequency of maximum points for a given image type. The factors associated with completing the scan in one session were evaluated with multivariate logistic regression. RESULTS: The obese group included 223 women and the control group 60; a complete scan in one session was achieved in 70.4% and 81.7% of these, respectively (P = 0.08). The completion rate for each image type was at least 95% in the control group and 90% in the obese group, except for diaphragm and right outflow tract images. Significant factors associated with completing the scan in the multivariate model were: having 10 additional minutes for the scan (P = 0.03), moving the fetus so that the back was in posterior or lateral position (P = 0.01), more experienced sonographer (P = 0.03) and thinner maternal abdominal wall thickness (P = 0.01). Overall, the excellence rate varied from 35% to 92% in the normal BMI group and from 18% to 58% in the obese group, and was significantly lower in the latter for all images except abdominal circumference (P = 0.26) and spine (P = 0.06). Anatomical quality scores were also significantly lower in the obese group (22.3 vs. 27.2; P = 0.001). CONCLUSION: Although ultrasound scans of obese pregnant women are feasible, image quality and global anatomical scores are significantly lower among obese than normal-weight women. However, certain simple improvements may increase fetal visualization.


Assuntos
Índice de Massa Corporal , Feto/anatomia & histologia , Obesidade/diagnóstico por imagem , Complicações na Gravidez/diagnóstico por imagem , Ultrassonografia Pré-Natal/normas , Adulto , Estudos de Casos e Controles , Estudos de Viabilidade , Feminino , Idade Gestacional , Humanos , Aumento da Imagem , Modelos Logísticos , Obesidade/complicações , Gravidez , Segundo Trimestre da Gravidez , Estudos Prospectivos , Fatores de Risco , Fatores de Tempo , Adulto Jovem
10.
Prenat Diagn ; 33(8): 751-8, 2013 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-23553686

RESUMO

OBJECTIVE: To analyze the outcome of maternal primary cytomegalovirus (CMV) infection. METHODS: Retrospective analysis of a cohort of 238 patients with maternal primary CMV infection detected at routine screening. The cases were managed with serial ultrasound (US) scans, and amniocentesis was performed in 36.1% of cases. All prenatal results were confirmed at birth. RESULTS: The average age was 31.9 (18-44) years. Patients were symptomatic in 21% of cases. The rate of intrauterine transmission was 24.9%, and it was 8.8%, 19%, 30.6%, 34.1% and 40% in the preconceptional period, the periconceptional period, and the first, second and third trimesters of pregnancy, respectively (p = 0.025). There was a significantly higher risk of US abnormalities when maternal infection occurred during the preconceptional or periconceptional period and the first trimester compared with later (p < 0.001). Because of US abnormalities, pregnancy was terminated in 18 cases at the parents' request. Three infected newborns were symptomatic; all three cases were suspected at US before birth. We did not observe any symptomatic fetal infection when maternal infection occurred after 14 weeks of gestation. A number of clinically asymptomatic cases (5.5%) developed hearing loss. CONCLUSION: The rate of materno fetal transmission is linearly correlated to the gestational age at infection. No severe case of congenital infection was observed if maternal infection occurred after 14 weeks of gestation.


Assuntos
Infecções por Citomegalovirus/diagnóstico por imagem , Infecções por Citomegalovirus/epidemiologia , Complicações Infecciosas na Gravidez/diagnóstico por imagem , Complicações Infecciosas na Gravidez/epidemiologia , Resultado da Gravidez/epidemiologia , Aborto Eugênico/estatística & dados numéricos , Adolescente , Adulto , Estudos de Coortes , Infecções por Citomegalovirus/transmissão , Feminino , Doenças Fetais/epidemiologia , Doenças Fetais/etiologia , Doenças Fetais/virologia , Humanos , Recém-Nascido , Doenças do Recém-Nascido/epidemiologia , Doenças do Recém-Nascido/etiologia , Transmissão Vertical de Doenças Infecciosas/estatística & dados numéricos , Gravidez , Ultrassonografia Pré-Natal/estatística & dados numéricos , Adulto Jovem
11.
Gynecol Obstet Fertil Senol ; 51(1): 73-75, 2023 01.
Artigo em Francês | MEDLINE | ID: mdl-36302474

RESUMO

Guidelines for adequate gestational weight gain were proposed in 2009 by the Institute of Medicine. In case of a BMI>30kg/m2, the recommended gestational weight gain should be between 5 and 9kg. However, these recommendations do not distinguish between different grades of obesity. Recent data suggest that the IOM recommendations are not restrictive enough for obese pregnant women and should be adapted to the grade of obesity.


Assuntos
Ganho de Peso na Gestação , Complicações na Gravidez , Estados Unidos , Gravidez , Feminino , Humanos , Resultado da Gravidez , Complicações na Gravidez/terapia , Obesidade/complicações , National Academies of Science, Engineering, and Medicine, U.S., Health and Medicine Division , Índice de Massa Corporal
12.
Gynecol Obstet Fertil Senol ; 51(1): 7-34, 2023 01.
Artigo em Francês | MEDLINE | ID: mdl-36228999

RESUMO

OBJECTIVE: To identify procedures to reduce maternal morbidity during cesarean. MATERIAL AND METHODS: The quality of evidence of the literature was assessed following the GRADE® method with questions formulated in the PICO format (Patients, Intervention, Comparison, Outcome) and outcomes defined a priori and classified according to their importance. An extensive bibliographic search was performed on PubMed, Cochrane and EMBASE databases. The quality of the evidence was assessed (high, moderate, low, very low) and a (i) strong or (ii) weak recommendations or (iii) no recommendation were formulated. The recommendations were reviewed in two rounds with external reviewers (Delphi survey) to select the consensus recommendations. RESULTS: Of the 27 questions, there was agreement between the working group and the external reviewers on 26. The level of evidence of the literature was insufficient to provide a recommendation on 15 questions. Preventing hypothermia is recommended to increase maternal satisfaction and comfort (weak recommendation) and to reduce neonatal hypothermia (strong recommendation). The quality of the evidence of the literature did not allow to recommend the skin disinfectant to be used nor the relevance of a preoperative vaginal disinfection nor the choice between the use or nonuse of an indwelling bladder catheterization (if micturition takes place 1 hour before the cesarean section). The Misgav-Ladach technique or its analogues should be considered rather than the Pfannenstiel technique to reduce maternal morbidity (weak recommendation) bladder flap before uterine incision should not be performed routinely (weak recommendation), but a blunt (weak recommendation) and cephalad-caudad extension of uterine incision (weak recommendation) should be considered to reduce maternal morbidity. Antibiotic prophylaxis is recommended to reduce maternal infectious morbidity (strong recommendation) without recommendation on its type or the timing of administration (before incision or after cord clamping). The administration of carbetocin after cord clamping does not significantly decrease the incidence of blood loss>1000 ml, anemia, or blood transfusion compared with the administration of oxytocin. Thus, it is not recommended to use carbetocin rather than oxytocin in cesarean. It is recommended that systematic manual removal of the placenta not to be performed (weak recommendation). An antiemetic should be administered after cord clamping in women having a planned cesarean under locoregional anaesthesia to reduce intraoperative and postoperative nausea and vomiting (strong recommendation) with no recommendation regarding choice of use one or two antiemetics. The level of evidence of the literature was insufficient to provide any recommendation concerning single or double-layer closure of the uterine incision, or the uterine exteriorization. Closing the peritoneum (visceral or parietal) should not be considered (weak recommendation). The quality of the evidence of the literature was not sufficient to provide recommendation on systematic subcutaneous closure, including in obese or overweight patients, or the use of subcuticular suture in obese or overweight patients. The use of subcuticular suture in comparison with skin closure by staples was not considered as a recommendation due to the absence of a consensus in the external review rounds. CONCLUSION: In case of cesarean, preventing hypothermia, administering antiemetic and antibiotic prophylaxis after cord clamping are the only strong recommendations. The Misgav-Ladach technique, the way of performing uterine incision (no systematic bladder flap, blunt cephalad-caudad extension), not performing routine manual removal of the placenta nor closure of the peritoneum are weak recommendations and may reduce maternal morbidity.


Assuntos
Cesárea , Obstetrícia , Feminino , Humanos , Recém-Nascido , Gravidez , Antieméticos , Cesárea/efeitos adversos , Cesárea/métodos , Cesárea/normas , Ginecologista , Hipotermia/etiologia , Hipotermia/prevenção & controle , Obesidade , Obstetra , Sobrepeso , Ocitocina , França , Obstetrícia/normas
13.
Phys Rev Lett ; 109(22): 226402, 2012 Nov 30.
Artigo em Inglês | MEDLINE | ID: mdl-23368138

RESUMO

Several systems in the solid state have been suggested as promising candidates for spin-based quantum information processing. In spite of significant progress during the last decade, there is a search for new systems with higher potential [D. DiVincenzo, Nat. Mater. 9, 468 (2010)]. We report that silicon vacancy defects in silicon carbide comprise the technological advantages of semiconductor quantum dots and the unique spin properties of the nitrogen-vacancy defects in diamond. Similar to atoms, the silicon vacancy qubits can be controlled under the double radio-optical resonance conditions, allowing for their selective addressing and manipulation. Furthermore, we reveal their long spin memory using pulsed magnetic resonance technique. All these results make silicon vacancy defects in silicon carbide very attractive for quantum applications.

14.
Neurochirurgie ; 68(6): 679-683, 2022 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-35907443

RESUMO

INTRODUCTION: Suprasellar Arachnoid Cysts (SAC) are rare heterogeneous entities. Though prenatally diagnosed, they are rarely treated pre-birth. Symptomatic cases are mainly seen in infants. CASE DESCRIPTION: We describe a case of a prenatally symptomatic suprasellar arachnoid cyst treated postnatally. The cyst was diagnosed on a routine ultrasound at 22 weeks, was rapidly evolving in the ultrasounds and the MRI of the 29th week. It then became symptomatic at 30 weeks with episodes of fetal bradycardia, independent to the uterine contractions. Antenatal treatment was discussed but delivery decided in emergency despite the prematurity via C-section. Though well tolerated postnatally, the cyst continued to grow. Endoscopic ventriculo-cysto-cisternostomy was performed on the 5th day of birth. Despite progressive reduction of the cyst, residual brainstem compression and evolving ventriculomegaly lead to a transient extrathecal internal shunting. DISCUSSION/CONCLUSION: Our case suggests that prenatally diagnosed cysts require a close follow-up. Treatment options and timing should be adapted to anatomy, cyst evolution and symptoms whether it is before or after birth.


Assuntos
Cistos Aracnóideos , Hidrocefalia , Lactente , Feminino , Humanos , Gravidez , Cistos Aracnóideos/diagnóstico por imagem , Cistos Aracnóideos/cirurgia , Hidrocefalia/cirurgia , Procedimentos Neurocirúrgicos , Endoscopia , Imageamento por Ressonância Magnética
15.
Gynecol Obstet Fertil Senol ; 50(1): 2-25, 2022 01.
Artigo em Francês | MEDLINE | ID: mdl-34781016

RESUMO

OBJECTIVE: To provide national guidelines for the management of women with severe preeclampsia. DESIGN: A consensus committee of 26 experts was formed. A formal conflict of interest (COI) policy was developed at the onset of the process and enforced throughout. The entire guidelines process was conducted independently of any industrial funding. The authors were advised to follow the principles of the Grading of Recommendations Assessment, Development and Evaluation (GRADE®) system to guide assessment of quality of evidence. The potential drawbacks of making strong recommendations in the presence of low-quality evidence were emphasized. METHODS: The last SFAR and CNGOF guidelines on the management of women with severe preeclampsia was published in 2009. The literature is now sufficient for an update. The aim of this expert panel guidelines is to evaluate the impact of different aspects of the management of women with severe preeclampsia on maternal and neonatal morbidities separately. The experts studied questions within 7 domains. Each question was formulated according to the PICO (Patients Intervention Comparison Outcome) model and the evidence profiles were produced. An extensive literature review and recommendations were carried out and analyzed according to the GRADE® methodology. RESULTS: The SFAR/CNGOF experts panel provided 25 recommendations: 8 have a high level of evidence (GRADE 1±), 9 have a moderate level of evidence (GRADE 2±), and for 7 recommendations, the GRADE method could not be applied, resulting in expert opinions. No recommendation was provided for 3 questions. After one scoring round, strong agreement was reached between the experts for all the recommendations. CONCLUSIONS: There was strong agreement among experts who made 25 recommendations to improve practices for the management of women with severe preeclampsia.


Assuntos
Anestesiologia , Médicos , Pré-Eclâmpsia , Consenso , Cuidados Críticos , Feminino , Humanos , Recém-Nascido , Pré-Eclâmpsia/terapia , Gravidez
16.
Gynecol Obstet Fertil Senol ; 49(2): 122-127, 2021 02.
Artigo em Francês | MEDLINE | ID: mdl-32919088

RESUMO

OBJECTIVES: Breaking bad news (BBN) to a pregnant woman with fetal abnormalities (FA) on ultrasound (US) examination is a challenge. Announcement technique influences patient reaction. Physicians receive little training in BBN. The simulation and using a BBN protocol as the English SPIKES protocol which guides the announcement consultation according to 6 steps (Setting Up, Perception, Invitation, Knowledge, Emotions and Empathy, Strategy and Summary) can be used for this teaching. The objective was to assess feasibility simulation scenarii of BBN for FA discovered during US and to evaluate the usefulness of SPIKES protocol in this situation. METHODS: Two scenarios have been created combining US simulator (US Mentor, Symbionix®) with simulated patient (SP). Scenarii objectives were to diagnose FA and break it to SP. Checklist derived from SPIKES was fulfilled by two investigators thanks to video recording, the SP and every participant (residents, physicians, fetal medicine specialists [FMS]). Participants filled out survey about the usefulness of this exercise too. RESULTS: Nine physicians (3 residents, 4 physicians, 2 FMS) produced 18 scenarii. Seventy-eight percent of physicians thought simulation was like real situation of BBN during US examination. Majority of participant (88%) found that this simulation training could help them to increase their ability to BBN and that it can be used to teach residents (89%) or physicians (100%). FMS had better SPIKES checklist than physicians (P<0,05). CONCLUSION: Simulation scenario of BBN for FA discovered during US is feasible by combining US simulator and SP. SPIKES protocol can be useful but a validated checklist should be created.


Assuntos
Médicos , Treinamento por Simulação , Comunicação , Feminino , Humanos , Projetos Piloto , Gravidez , Revelação da Verdade
17.
Gynecol Obstet Fertil Senol ; 49(10): 782-791, 2021 Oct.
Artigo em Francês | MEDLINE | ID: mdl-33677120

RESUMO

The burden of congenital toxoplasmosis has become small in France today, in particular as a result of timely therapy for pregnant women, fetuses and newborns. Thus, the French screening and prevention program has been evaluated and recently confirmed despite a decline over time in the incidence of toxoplasmosis. Serological diagnosis of maternal seroconversion is usually simple but can be difficult when the first trimester test shows the presence of IgM, requiring referral to an expert laboratory. Woman with confirmed seroconversion should be referred quickly to an expert center, which will decide with her on treatment and antenatal diagnosis. Although the level of proof is moderate, there is a body of evidence in favor of active prophylactic prenatal treatment started as early as possible (ideally within 3 weeks of seroconversion) to reduce the risk of maternal-fetal transmission, as well as symptoms in children. The recommended therapies to prevent maternal-fetal transmission are: (1) spiramycin in case of maternal infection before 14 gestational weeks; (2) pyrimethamine and sulfadiazine (P-S) with folinic acid in case of maternal infection at 14 WG or more. Amniocentesis is recommended to guide prenatal and neonatal care. If fetal infection is diagnosed by PCR on amniotic fluid, therapy with P-S should be initiated as early as possible or continued in order reduce the risk of damage to the brain or eyes. Further research is required to validate new approaches to preventing congenital toxoplasmosis.


Assuntos
Complicações Infecciosas na Gravidez , Toxoplasmose Congênita , Toxoplasmose , Criança , Feminino , Humanos , Recém-Nascido , Transmissão Vertical de Doenças Infecciosas/prevenção & controle , Gravidez , Complicações Infecciosas na Gravidez/diagnóstico , Complicações Infecciosas na Gravidez/tratamento farmacológico , Diagnóstico Pré-Natal , Toxoplasmose/diagnóstico , Toxoplasmose/tratamento farmacológico , Toxoplasmose Congênita/diagnóstico , Toxoplasmose Congênita/tratamento farmacológico , Toxoplasmose Congênita/prevenção & controle
18.
Prenat Diagn ; 30(1): 40-2, 2010 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-19960449

RESUMO

OBJECTIVE: To compare retrospectively the distribution of foetal biometry data as measured by midwives and physicians during second and third trimester screening of an unselected population of pregnant women. METHODS: Standard measurements of biparietal diameter (BPD), head circumference (HC), abdominal circumference (AC), and femur length (FL) were performed by four midwives and ten physicians at 20 to 24 weeks of gestation and at 30 to 34 weeks of gestation as part of routine ultrasound examinations over a 26-month period (Jan. 2005-Mar. 2007). All measurements were converted into Z-scores using different prediction equations. The reference chart best fitting our practice was determined for each fetal parameter (French College of Sonographers for BPD, Chitty et al. for HC and FL, Snidjers and Nicolaides for AC). The means and SDs of the Z-score distributions for data collected by midwives and physicians were compared using Student's t-test for means and the Fisher-Snedecor test for SDs. RESULTS: We retrieved 1566 and 1631 measurements made by midwives and physicians respectively between 20 and 24 weeks of gestation, and 1710 and 1578 measurements made by midwives and physicians respectively between 30 and 34 weeks of gestation. Mean values recorded by midwives were significantly closer to 0 (p < 0.05) for many foetal parameters. SD values were also significantly lower and were below 1. CONCLUSION: In this study, midwives have a greater tendency than physicians to normalize biometry data. Such normalization may hamper the sensitivity of routine ultrasound screening for abnormal foetal growth.


Assuntos
Biometria/métodos , Feto/anatomia & histologia , Tocologia , Médicos , Ultrassonografia Pré-Natal/métodos , Adulto , Feminino , Desenvolvimento Fetal , Humanos , Programas de Rastreamento , Gravidez , Segundo Trimestre da Gravidez , Terceiro Trimestre da Gravidez , Valores de Referência , Estudos Retrospectivos , Sensibilidade e Especificidade , Ultrassonografia Pré-Natal/estatística & dados numéricos
19.
Histochem Cell Biol ; 132(1): 83-93, 2009 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-19319559

RESUMO

Merkel cells (MCs) are neuroendocrine cells of unknown origin located in the skin. They are identified at electron microscopic level by electron dense granules, at light microscopic level by the presence of cytokeratins 8, 18, 19 and 20. Contradictory reports concerning the presence of other molecules of epithelial as well as neural origin prompted us to investigate whether there are distinct populations of human MCs. Here, we show the heterogeneous expression of villin, N-CAM, NGF-R, and neurofilaments in MCs. Synaptophysin is found in all MCs but with different intensity, nestin is absent. Expression patterns vary between interfollicular epidermis, hair follicles and glabrous epidermis. We conclude that there are distinct populations of MCs, but all populations contain markers for epithelial as well as neural cells. Putative functions of the distinct populations are discussed.


Assuntos
Células de Merkel/citologia , Antígenos de Diferenciação/metabolismo , Linhagem da Célula , Células Epidérmicas , Epiderme/metabolismo , Folículo Piloso/citologia , Folículo Piloso/metabolismo , Humanos , Imuno-Histoquímica , Filamentos Intermediários/metabolismo , Células de Merkel/metabolismo , Células Neuroendócrinas/citologia , Células Neuroendócrinas/metabolismo
20.
Science ; 215(4538): 1396-8, 1982 Mar 12.
Artigo em Inglês | MEDLINE | ID: mdl-6278592

RESUMO

The concentration of oxytocin receptors increased in the myometrium of pregnant women and reached maximum levels in early labor. Concentrations of oxytocin receptors were also high in the decidua and reached a maximum at parturition. In vitro, prostaglandin production by the decidua, but not by the myometrium, was increased by the addition of oxytocin. Oxytocin may therefore stimulate uterine contractions by acting both directly on the myometrium and indirectly on decidual prostaglandin production. Oxytocin receptors are probably crucial for the onset of human labor, and the stimulus for the increase in uterine prostaglandins may be oxytocin originating from the fetus.


Assuntos
Trabalho de Parto , Ocitocina/fisiologia , Receptores de Superfície Celular/fisiologia , Útero/fisiologia , Decídua/fisiologia , Feminino , Humanos , Miométrio/fisiologia , Gravidez , Prostaglandinas E/biossíntese , Prostaglandinas F/biossíntese
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA