Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 42
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
J Thromb Thrombolysis ; 56(1): 45-54, 2023 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-37061662

RESUMO

Data from several recent studies have demonstrated the safety and efficacy of transcatheter aortic valve implantation (TAVI) for severe aortic stenosis (AS) even in nonagenarians. However, the impact of periprocedural bleeding following TAVI on their outcome remains unclear. In the aLliAnce for exPloring cLinical prospects of AortiC valvE disease (LAPLACE) registry, we compared outcomes between the bleeding and no-bleeding groups among 1953 patients < 90 years old (mean age, 83.0 ± 4.6 years old) and 316 nonagenarians (mean age, 91.7 ± 1.9 years old) who underwent TAVI with a median follow-up period of 628 days. The group with any periprocedural bleeding showed a higher 30-day mortality than the no-bleeding group in patients < 90 years old (3.3% vs. 0.5%, p = 0.001) and nonagenarians (7.9% vs. 0.7%, p = 0.001). In patients < 90 years old, severe periprocedural bleeding (n = 85) was associated with a higher mid-term all-cause mortality rate than no severe bleeding (n = 1,868), even after adjusting for covariates (hazard ratio [HR], 1.994; 95% confidence interval [CI] 1.287-2.937; p = 0.002). On the other hand, in nonagenarians, any periprocedural bleeding (n = 38) was associated with a higher mid-term cardiovascular (CV) mortality rate (21.1% vs. 4.3%, log-rank p = 0.014) than no bleeding (n = 278), even after adjusting for covariates (HR, 3.104; 95% CI 1.140-8.449; p = 0.027). In conclusion, any periprocedural bleeding after TAVI was associated with mid-term CV mortality in nonagenarians, whereas severe bleeding was associated with mid-term all-cause mortality in patients < 90 years old.


Assuntos
Estenose da Valva Aórtica , Substituição da Valva Aórtica Transcateter , Idoso de 80 Anos ou mais , Humanos , Idoso , Substituição da Valva Aórtica Transcateter/efeitos adversos , Nonagenários , Estenose da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/complicações , Fatores de Risco , Valva Aórtica/cirurgia , Hemorragia/etiologia , Sistema de Registros , Resultado do Tratamento
2.
Catheter Cardiovasc Interv ; 99(7): 2131-2135, 2022 06.
Artigo em Inglês | MEDLINE | ID: mdl-35353943

RESUMO

The Inoue balloon, invented for percutaneous transseptal mitral commissurotomy for mitral stenosis, is initially dilated in the distal portion and then the proximal portion, forming an hourglass shape that stabilizes the balloon at the mitral valve orifice with a pulling action. The device has been successfully applied to antegrade aortic valvuloplasty; the hourglass shape stabilizes the balloon across the aortic valve without rapid ventricular pacing. Subsequently, an Inoue balloon was developed for retrograde aortic valvuloplasty using the same design as the antegrade balloon. The hourglass-shaped balloon, however, has difficulty maintaining stability across the aortic valve because the distal portion of the balloon, which inflates first, directly receives systolic pressure from the left ventricle. A novel Inoue balloon was invented to overcome this issue by altering the manner of inflation: the proximal portion inflates first, followed by the distal portion. Theoretically, the proximal portion, which initially inflates just above the aortic valve, remains secure across the valve by applying a pressing force that counteracts the systolic forward pressure. Furthermore, a radiopaque marker is placed at the center of the balloon to enable rapid and precise balloon adjustment. We present a case involving a 65-year-old female hemodialysis patient with severe symptomatic aortic stenosis who we successfully treated with balloon aortic valvuloplasty using the novel Inoue balloon followed by transcatheter aortic valve implantation. The present case demonstrates the feasibility and effectiveness of the novel "proximal first" Inoue balloon for retrograde balloon aortic valvuloplasty for severe aortic stenosis.


Assuntos
Estenose da Valva Aórtica , Valvuloplastia com Balão , Estenose da Valva Mitral , Idoso , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Cateterismo Cardíaco , Catéteres , Feminino , Humanos , Estenose da Valva Mitral/diagnóstico por imagem , Estenose da Valva Mitral/terapia , Resultado do Tratamento
3.
Catheter Cardiovasc Interv ; 97(3): E418-E424, 2021 02 15.
Artigo em Inglês | MEDLINE | ID: mdl-32609437

RESUMO

OBJECTIVES: This study aimed to assess the feasibility and safety of conducting an entire transcatheter aortic valve replacement (TAVR) program by using percutaneous techniques only. BACKGROUND: Surgically assisted transthoracic TAVR has been reported to be associated with more complications and longer hospital stays. METHODS: During 2019, all TAVR at a single center were performed by standard transfemoral (TF), intravascular lithotripsy-assisted TF, transaxillary (TAx), or transcaval approach using percutaneous techniques only. No patients were denied TAVR because of access. Procedural and clinical endpoints were categorized using Valve Academic Research Consortium-2 criteria. RESULTS: In total, 306 consecutive TAVR patients were enrolled (mean age 78.9 ± 7.2 years). Most patients were treated by TF approach (94.8%)-of these, nine (2.9%) were pre-treated with intravascular lithotripsy. A percutaneous TAx and transcaval approach were used in 12 (3.9%) and four patients (1.3%), respectively. There were no procedural deaths and one peri-procedural stroke. Valve performance was satisfying in 298 patients (97.4%); six patients had a moderate aortic regurgitation and two patients had a mean gradient ≥20 mmHg following valve-in-valve procedure. The 30-day major vascular complication and major bleeding rate was 2.3% and 3.9%, respectively. A new permanent pacemaker was implanted in 41 patients (13.4%). Of all patients, 81% were discharged within two days post-TAVR, including 11 out of 12 TAx patients and all transcaval cases. CONCLUSIONS: A fully percutaneous TAVR program is feasible and safe with favorable immediate and early clinical outcomes and allowing a short hospital stay.


Assuntos
Estenose da Valva Aórtica , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Idoso , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Estudos de Viabilidade , Humanos , Fatores de Risco , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento
4.
Catheter Cardiovasc Interv ; 98(3): E356-E364, 2021 09.
Artigo em Inglês | MEDLINE | ID: mdl-33861509

RESUMO

OBJECTIVES: We evaluated the in-hospital outcomes of percutaneous coronary intervention (PCI) for bypass graft vessels (GV-PCI) compared with those of PCI for native vessels (NV-PCI) using data from the Japanese nationwide coronary intervention registry. METHODS: We included PCI patients (N = 748,229) registered between January 2016 and December 2018 from 1,123 centers. We divided patients into three groups: GV-PCI (n = 2,745); NV-PCI with a prior coronary artery bypass graft (pCABG) (n = 23,932); and NV-PCI without pCABG (n = 721,552). RESULTS: GV-PCI implementation was low, and most cases of PCI in pCABG patients were performed in native vessels (89.7%) in contemporary Japanese practice. The risk profile of patients with pCABG was higher than that of those without pCABG. Consequently, GV-PCI patients had a significantly higher in-hospital mortality than NV-PCI patients without pCABG after adjusting for covariates (odds ratio [OR] 2.36, 95% confidence interval [CI] 1.66-3.36, p < .001). Of note, embolic protection devices (EPDs) were used in 18% (n = 383) of PCIs for saphenous vein grafts (SVG-PCI) with a significant variation in its use among institutions (number of PCI: hospitals that had never used an EPD vs. EPD used one or more times = 240 vs. 345, p < .001). The EPDs used in the SVG-PCI group had a significantly lower prevalence of the slow-flow phenomenon after adjusting for covariates (OR 0.45, 95% CI 0.21-0.91, p = .04). CONCLUSION: GV-PCI is associated with an increased risk of in-hospital mortality. EDP use in SVG-PCI was associated with a low rate of the slow-flow phenomenon. The usage of EPDs during SVG-PCI is low, with a significant variation among institutions.


Assuntos
Dispositivos de Proteção Embólica , Intervenção Coronária Percutânea , Ponte de Artéria Coronária/efeitos adversos , Oclusão de Enxerto Vascular/etiologia , Hospitais , Humanos , Japão , Intervenção Coronária Percutânea/efeitos adversos , Sistema de Registros , Estudos Retrospectivos , Fatores de Risco , Veia Safena/diagnóstico por imagem , Veia Safena/cirurgia , Resultado do Tratamento
5.
Catheter Cardiovasc Interv ; 98(7): E1017-E1025, 2021 12 01.
Artigo em Inglês | MEDLINE | ID: mdl-34390167

RESUMO

OBJECTIVES: To report on the experience with a selective prophylactic permanent pacemaker (PPx-PPM) implantation strategy in patients with pre-existing right bundle branch block (RBBB) undergoing transcatheter aortic valve replacement (TAVR). BACKGROUND: Pre-existing RBBB is an independent predictor for PPM after TAVR and has been linked to increased mortality. METHODS: Hospital patient flow and longer-term clinical endpoints were compared for TAVR patients with pre-existing RBBB treated in a period with and without selective PPx-PPM strategy (2013-2020). RESULTS: A total of 260 patients were included: 170 in the early period without PPx-PPM strategy and 90 patients in the late period with selective PPx-PPM strategy. A PPx-PPM was implanted in 44% of patients in the late period. Overall, 69% versus 80% of all patients in the early versus late period ended up with a PPM (p = .06). Streamlined transfemoral TAVR was routinely used from 2017-in this series of patients, both TAVR procedural time and hospital length of stay (LoS) were significantly shorter in the late versus early period (mean procedural time: 70 vs. 83 min and LoS ≥5 days: 15% vs. 40%; p < .05). No difference in all-cause/cardiovascular mortality was observed between both strategies, whereas cardiac rehospitalization was significantly higher for patients treated in the early versus late period (hazard ratio 2.33 [1.04-5.26]; p = .042)-this mainly due to (sub)acute PPM-implantation early after discharge. CONCLUSIONS: Selective prophylactic PPM implantation in TAVR candidates with pre-existing RBBB results in shorter TAVR procedural time and hospital LoS and prevents early cardiac rehospitalization related to complete heart block.


Assuntos
Estenose da Valva Aórtica , Marca-Passo Artificial , Substituição da Valva Aórtica Transcateter , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Bloqueio de Ramo/diagnóstico , Bloqueio de Ramo/etiologia , Bloqueio de Ramo/terapia , Estimulação Cardíaca Artificial/efeitos adversos , Humanos , Fatores de Risco , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento
6.
Circ J ; 85(10): 1797-1805, 2021 09 24.
Artigo em Inglês | MEDLINE | ID: mdl-33658442

RESUMO

BACKGROUND: The high mortality of acute myocardial infarction (AMI) with cardiogenic shock (i.e., Killip class IV AMI) remains a challenge in emergency cardiovascular care. This study aimed to examine institutional factors, including the number of JCS board-certified members, that are independently associated with the prognosis of Killip class IV AMI patients.Methods and Results:In the Japanese registry of all cardiac and vascular diseases-diagnosis procedure combination (JROAD-DPC) database (years 2012-2016), the 30-day mortality of Killip class IV AMI patients (n=21,823) was 42.3%. Multivariate analysis identified age, female sex, admission by ambulance, deep coma, and cardiac arrest as patient factors that were independently associated with higher 30-day mortality, and the numbers of JCS board-certified members and of intra-aortic balloon pumping (IABP) cases per year as institutional factors that were independently associated with lower mortality in Killip class IV patients, although IABP was associated with higher mortality in Killip classes I-III patients. Among hospitals with the highest quartile (≥9 JCS board-certified members), the 30-day mortality of Killip class IV patients was 37.4%. CONCLUSIONS: A higher numbers of JCS board-certified members was associated with better survival of Killip class IV AMI patients. This finding may provide a clue to optimizing local emergency medical services for better management of AMI patients in Japan.


Assuntos
Infarto do Miocárdio , Choque Cardiogênico , Feminino , Humanos , Balão Intra-Aórtico , Japão/epidemiologia , Infarto do Miocárdio/diagnóstico , Prognóstico , Choque Cardiogênico/complicações , Choque Cardiogênico/diagnóstico , Choque Cardiogênico/terapia
7.
Heart Vessels ; 36(9): 1275-1282, 2021 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-33677618

RESUMO

Hemodialysis (HD) patients tend to have sarcopenia and malnutrition, and both conditions are related to poor prognosis in the cardiovascular disease that often accompanies HD. However, the impact of sarcopenia or malnutrition on the long-term prognosis of HD patients undergoing percutaneous coronary intervention (PCI) for acute coronary syndrome (ACS) remains unclear. We analyzed 1,605 consecutive patients with ACS who had undergone PCI at a single center between January 2009 and December 2014. We evaluated all-cause mortality and prognosis-associated factors, including sarcopenia/malnutrition-related factors such as the Geriatric Nutritional Risk Index (GNRI), and Skeletal Muscle Mass Index (SMI). After exclusions, 1461 patients were enrolled, and 58 (4.0%) were on HD. The HD group had lower levels of SMI and GNRI than non-HD group, and had worse in-hospital prognosis. Moreover, HD group had a significant higher mortality in the long-term follow-up [median follow-up period: 1219 days; Hazard Ratio (HR) = 4.09, p < 0.001]. After adjusting the covariates, SMI and GNRI were the factors associated with all-cause mortality in all patients [SMI: adjusted HR (aHR) = 2.39, p = 0.036; GNRI: aHR = 2.21, p = 0.006]; however, these findings were not observed among HD patients with ACS, and only diabetes was significantly associated with all-cause mortality (diabetes: aHR = 3.50, p = 0.031). HD patients with ACS had a significantly higher rate of in-hospital and long-term mortality than non-HD patients. Although sarcopenia and malnutrition were related to mortality and were more common in HD patients, sarcopenia and malnutrition had a lower impact than diabetes on the long-term prognosis of HD patients with ACS.


Assuntos
Síndrome Coronariana Aguda , Desnutrição , Intervenção Coronária Percutânea , Sarcopenia , Síndrome Coronariana Aguda/diagnóstico , Síndrome Coronariana Aguda/etiologia , Síndrome Coronariana Aguda/terapia , Idoso , Avaliação Geriátrica , Humanos , Desnutrição/complicações , Desnutrição/diagnóstico , Desnutrição/epidemiologia , Avaliação Nutricional , Estado Nutricional , Intervenção Coronária Percutânea/efeitos adversos , Prognóstico , Diálise Renal , Fatores de Risco , Sarcopenia/complicações , Sarcopenia/diagnóstico , Sarcopenia/epidemiologia
8.
Catheter Cardiovasc Interv ; 93(5): E262-E268, 2019 04 01.
Artigo em Inglês | MEDLINE | ID: mdl-30244539

RESUMO

BACKGROUND: The optimum timing of revascularization strategy for stenoses in nonculprit vessels in patients with ST-segment elevation myocardial infarction (STEMI) and multivessel disease (MVD) remains unclear. At present, there is no evidence investigating the outcome of staged percutaneous coronary intervention (PCI) within two weeks from admission among STEMI patients with MVD. METHODS: A total of 210 STEMI patients with MVD who underwent primary PCI were analyzed. We compared the all-cause mortality and major adverse cardiovascular events (MACE) (cardiovascular death, myocardial infarction, heart failure, unstable angina, and stroke) with median follow-up of 1200 days among the patients who underwent staged PCI within two weeks from admission (staged PCI ≤2 W) (n = 75), staged PCI after two weeks from admission (staged PCI >2 W) (n = 37) and culprit-only PCI (n = 98) in patients with STEMI and MVD. RESULTS: The staged PCI ≤2 W showed lower all-cause mortality than culprit-only PCI (4.0 vs 29.6%, log-rank P = 0.001), and lower incidence of MACE than the staged PCI >2 W group (1.3 vs 18.9%, log-rank P = 0.001) and culprit-only PCI group (1.3 vs 22.5%, log-rank P = 0.001). In the multivariable Cox regression analysis, the staged PCI ≤2 W was a predictor of lower all-cause mortality (hazard ratio [HR], 0.176; 95% confidence interval [CI], 0.049-0.630; P = 0.008) and lower incidence of MACE (HR, 0.068; 95% CI, 0.009-0.533; P = 0.011), but staged PCI >2 W was not. CONCLUSION: In conclusion, staged PCI within two weeks after admission showed more favorable outcomes compared with staged PCI after two weeks from admission or culprit-only PCI in STEMI patients with MVD.


Assuntos
Doença da Artéria Coronariana/terapia , Estenose Coronária/terapia , Admissão do Paciente , Intervenção Coronária Percutânea , Infarto do Miocárdio com Supradesnível do Segmento ST/terapia , Tempo para o Tratamento , Idoso , Idoso de 80 Anos ou mais , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/mortalidade , Estenose Coronária/diagnóstico por imagem , Estenose Coronária/mortalidade , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Intervenção Coronária Percutânea/efeitos adversos , Intervenção Coronária Percutânea/mortalidade , Estudos Retrospectivos , Fatores de Risco , Infarto do Miocárdio com Supradesnível do Segmento ST/diagnóstico por imagem , Infarto do Miocárdio com Supradesnível do Segmento ST/mortalidade , Fatores de Tempo , Resultado do Tratamento
9.
Heart Vessels ; 34(8): 1241-1249, 2019 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-30715570

RESUMO

Cardiogenic shock frequently leads to death even with intensive treatment. Although the leading cause of cardiogenic shock is acute coronary syndrome (ACS), the clinical characteristics and the prognosis of ACS with cardiogenic shock in the present era still remain to be elucidated. We analyzed clinical characteristics and predictors of 30-day mortality in ACS with cardiogenic shock in Japan. The Japanese Circulation Society Cardiovascular Shock registry was a prospective, observational, multicenter, cohort study. Between May 2012 and June 2014, 495 ACS patients with cardiogenic shock were analyzed. The primary endpoint was 30-day all-cause mortality. The median [interquartile range; IQR] age was 71.0 [63.0, 80.0] years. The median [IQR] value of systolic blood pressure (SBP) and heart rate were 75.0 [50.0, 86.5] mm Hg and 65.0 [38.0, 98.0] bpm, respectively. Multivariable analysis showed an odds ratio (OR) of 4.76 (confidence intervals; CI 1.97-11.5, p < 0.001) in the lowest SBP category (< 50 mm Hg) for SBP ≥ 90 mm Hg. Moreover, age per 10 years increase (OR 1.38, CI 1.18-1.61, p = 0.002), deep coma (OR 3.49, CI 1.94-6.34, p < 0.001), congestive heart failure (OR 3.81, CI 2.04-7.59, p < 0.001) and left main trunk disease (LMTD) (OR 2.81, CI 1.55-5.10, p < 0.001) were independent predictors. Severe hypotension, older age, deep coma, congestive heart failure, and LMTD were independent unfavorable factors in ACS complicated by cardiogenic shock in Japan. A prompt assessment of high-risk patients referring to those predictors in emergency room could lead to appropriate treatment without delay.


Assuntos
Síndrome Coronariana Aguda/complicações , Insuficiência Cardíaca/complicações , Sistema de Registros , Choque Cardiogênico/mortalidade , Síndrome Coronariana Aguda/mortalidade , Fatores Etários , Idoso , Idoso de 80 Anos ou mais , Pressão Sanguínea , Feminino , Insuficiência Cardíaca/mortalidade , Frequência Cardíaca , Humanos , Japão/epidemiologia , Estimativa de Kaplan-Meier , Modelos Logísticos , Masculino , Pessoa de Meia-Idade , Análise Multivariada , Prognóstico , Estudos Prospectivos , Fatores de Risco , Choque Cardiogênico/etiologia , Choque Cardiogênico/fisiopatologia , Fatores de Tempo
10.
Int Heart J ; 60(5): 1184-1188, 2019 Sep 27.
Artigo em Inglês | MEDLINE | ID: mdl-31484860

RESUMO

We report the case of a 79-year-old man with acute myocardial infarction caused by left main trunk lesion, who experienced cardiogenic shock during percutaneous coronary intervention (PCI). To reverse the cardiogenic shock, we initiated veno-arterial extra corporeal membrane oxygenation (VA-ECMO) without an intra-aortic balloon pump (IABP) due to the severe tortuosity of the left external iliac artery. Although PCI was successful, arterial pressure monitoring revealed that the pulse pressure was too low to recover from the cardiogenic shock of decreased cardiac contraction function (the left ventricular ejection fraction was 30%). Thus, we decided to use IABP from the brachial artery to improve the hemodynamics. Immediately after the deployment of a 6-Fr IABP system (Takumi) from the left brachial artery, the pulse pressure was restored and finally VA-ECMO was withdrawn from the patient without complications. Although using IABP in combination with VA-ECMO is a reasonable strategy for cardiogenic shock, the effectiveness of this combination remains controversial. In this case, IABP added to VA-ECMO clearly achieved an improvement of pulse pressure and vital signs. Based on this result, monitoring of the pulse waveform is an effective tool to determine whether the concomitant use of IABP with VA-ECMO is indicated. Moreover, when it is difficult to insert IABP from the femoral arteries, the use of a 6-Fr IABP system (Takumi) approaching from the brachial artery should be considered.


Assuntos
Oxigenação por Membrana Extracorpórea/métodos , Balão Intra-Aórtico/métodos , Infarto do Miocárdio/complicações , Intervenção Coronária Percutânea/efeitos adversos , Choque Cardiogênico/terapia , Idoso , Pressão Sanguínea/fisiologia , Dor no Peito/diagnóstico , Dor no Peito/etiologia , Terapia Combinada , Serviço Hospitalar de Emergência , Seguimentos , Humanos , Masculino , Infarto do Miocárdio/diagnóstico , Infarto do Miocárdio/terapia , Intervenção Coronária Percutânea/métodos , Medição de Risco , Choque Cardiogênico/etiologia , Resultado do Tratamento
11.
Int Heart J ; 57(6): 760-762, 2016 Dec 02.
Artigo em Inglês | MEDLINE | ID: mdl-27829644

RESUMO

A 39-year-old man exhibiting unstable angina was admitted to our hospital, and urgent coronary angiography revealed stenosis of the proximal left anterior descending coronary artery (LAD). A drug eluting stent was implanted at this site, and the patient was discharged uneventfully on the 3rd hospital day. Optical frequency-domain imaging (OFDI) was successful in detecting an intra-plaque hematoma, minor intimal disruption, and thrombus at the culprit lesion in this patient. These observations suggest that this hematoma might be the result of subsequent blood filling into the ruptured plaque through this minor intimal disruption.


Assuntos
Síndrome Coronariana Aguda/diagnóstico por imagem , Hematoma/diagnóstico por imagem , Placa Aterosclerótica/diagnóstico por imagem , Tomografia de Coerência Óptica , Síndrome Coronariana Aguda/complicações , Adulto , Hematoma/complicações , Humanos , Masculino , Placa Aterosclerótica/complicações , Túnica Íntima/diagnóstico por imagem
12.
Clin Exp Hypertens ; 35(1): 40-4, 2013.
Artigo em Inglês | MEDLINE | ID: mdl-22631049

RESUMO

The aim of this study was to compare the differences in the levels of a highly sensitive cardiac troponin T (Hs-cTnT) between Losartan (LOS) plus hydrochlorothiazide (HCTZ) and amlodipine. Seventy-eight hypertensive patients were randomized to receive LOS/HCTZ or amlodipine for 8 weeks. Both treatments decreased clinic and 24-hour blood pressure to the same extent. The Hs-cTnT level was significantly reduced in the amlodipine group (P < .05), but such a reduction was not found in the LOS/HCTZ group in the upper half group of Hs-cTnT level at baseline. Amlodipine had a more beneficial effect than LOS/HCTZ in patients with high Hs-cTnT levels.


Assuntos
Anti-Hipertensivos/uso terapêutico , Hipertensão/sangue , Hipertensão/tratamento farmacológico , Troponina T/sangue , Idoso , Anlodipino/uso terapêutico , Bloqueadores do Receptor Tipo 1 de Angiotensina II/uso terapêutico , Biomarcadores/sangue , Pressão Sanguínea/efeitos dos fármacos , Bloqueadores dos Canais de Cálcio/uso terapêutico , Combinação de Medicamentos , Feminino , Humanos , Hidroclorotiazida/uso terapêutico , Hipertensão/fisiopatologia , Losartan/uso terapêutico , Masculino , Pessoa de Meia-Idade , Peptídeo Natriurético Encefálico/sangue
13.
Eur Heart J Case Rep ; 7(8): ytad328, 2023 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-37554958

RESUMO

Background: Previous reports have shown a mitral annuloplasty-like effect after MitraClip, i.e. a shortening of the anterior-posterior diameter of mitral valve annulus. However, the clinical benefit of this phenomenon is unclear. Case summary: An 87-year-old woman with multiple degenerative mitral regurgitation (MR) jets, including a central-medial jet and a lateral jet, underwent MitraClip procedure. After a single clip implantation, anterior-posterior diameter of mitral annulus was shortened and both MR jets were significantly reduced. Discussion: Even in the case of multiple MR jets, a single clip deployment with the MitraClip system may provide an acceptable MR reduction if the clip shows the mitral annuloplasty effect.

14.
Eur Heart J Case Rep ; 7(11): ytad555, 2023 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-38025120

RESUMO

Background: Transcatheter aortic valve implantation (TAVI) requires several bail-out techniques for safe valve delivery and deployment. Particularly in cases of challenging aortic anatomy, the snare technique from the contralateral side of the surgical site can facilitate delivery of the transcatheter heart valve (THV) system. However, there are no previous reports of the snare technique from the ipsilateral side of the surgical site in TAVI cases. Case summary: A 77-year-old woman presented with severe aortic stenosis and congestive heart failure. As computed tomography showed a heavily calcified aortic arch, we performed TAVI using the ipsilateral snare technique to control the direction of the Evolut THV system. There was no haematoma or excessive bleeding at the surgical site during the procedure, and the patient was discharged without complications. Discussion: In cases with challenging anatomy of the aorta, the ipsilateral snare technique may be useful for the safe delivery of the Evolut system.

15.
Arch Cardiovasc Dis ; 116(2): 79-87, 2023 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-36641243

RESUMO

BACKGROUND: In transcatheter aortic valve implantation, high implantation on the aortic annulus may prevent conduction pathway injury, leading to a decrease in the rate of permanent pacemaker implantation. AIM: To assess the impact of high implantation of SAPIEN 3 on the prevention of permanent pacemaker implantation. METHODS: Since August 2020, we have performed high implantation by fluoroscopically positioning the lower part of the lucent line at the virtual basal ring line on a coplanar view before valve implantation. Patients treated before the adoption of this method were defined as the conventional group. We compared the high implantation group with the conventional group using propensity score analysis. RESULTS: Overall, the high implantation group (n=95) showed a significantly shorter ventricular strut length than the conventional group (n=85): median 1.3 (interquartile range 0.2-2.4) mm vs 2.8 (1.8-4.1) mm (P<0.001). The permanent pacemaker implantation rate was significantly lower in the high implantation group than in the conventional group (2.1% vs 11.8%; P=0.009). According to 100 propensity score analyses based on multiple imputation and the selection of appropriate covariates, the median P value for the comparison of permanent pacemaker implantation rates after transcatheter aortic valve implantation between the high implantation group and the conventional group ranged between 0.001 and 0.017, indicating a more significant reduction in the permanent pacemaker implantation rate in the high implantation group than in the conventional group. Neither valve dislodgement nor the need for a second valve was observed in either group. CONCLUSIONS: The high implantation of SAPIEN 3 successfully decreases ventricular strut length, reducing the permanent pacemaker implantation rate after transcatheter aortic valve implantation.


Assuntos
Estenose da Valva Aórtica , Próteses Valvulares Cardíacas , Marca-Passo Artificial , Substituição da Valva Aórtica Transcateter , Humanos , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Pontuação de Propensão , Próteses Valvulares Cardíacas/efeitos adversos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/métodos , Resultado do Tratamento , Desenho de Prótese
16.
Am J Cardiol ; 205: 198-203, 2023 10 15.
Artigo em Inglês | MEDLINE | ID: mdl-37611410

RESUMO

This study aimed to evaluate the incidence, predictors, and outcomes of Impella-assisted patients with cardiogenic shock, stratified by the access site-transaxillary (TX) or trans-subclavian (TS) versus the conventional transfemoral (TF) approach. For this study, we analyzed the cases entered into the Japanese Percutaneous Ventricular Assist Device registry between February 2020 and December 2021. A multivariable logistic regression analysis was conducted to calculate the adjusted odds ratio (aOR) and 95% confidence intervals (CIs) to identify the predictors of the TX/TS approach, with reference to those who received the conventional TF approach. A log-rank test was performed to compare the 30-day mortality between the 2 approaches. A total of 2,564 cases of Impella were included in the study, of which 167 (6.5%) were accessed by way of the TX/TS approach. TX/TS approach cases were younger and had a higher percentage of concomitant use of extracorporeal membrane oxygenation or an intra-aortic balloon pump. The predictors of the TX/TS approach included a presentation with the acute coronary syndrome (aOR 0.32, 95% CI 0.16 to 0.63, p <0.001), cardiac arrest (aOR 0.10, 95% CI 0.02 to 0.36, p = 0.003), cardiogenic shock (aOR 0.51, 95% CI 0.33 to 0.79, p = 0.002), and inotropic use (aOR 1.88, 95% CI 1.08 to 3.49, p = 0.033). The 30-day mortality was comparable between TX/TS and TF approaches (29.3% vs 29.6%, respectively; log-rank, p = 0.64). Our analysis revealed that approximately 6% of the Impella-assisted patients with cardiogenic shock received the TX/TS approach as their first access site. These results suggest that the TX/TS approach may be a viable alternative to the TF approach in certain patients requiring Impella support.


Assuntos
Síndrome Coronariana Aguda , Oxigenação por Membrana Extracorpórea , Parada Cardíaca , Humanos , Incidência , Choque Cardiogênico/epidemiologia , Choque Cardiogênico/terapia
17.
Am J Cardiol ; 209: 36-41, 2023 12 15.
Artigo em Inglês | MEDLINE | ID: mdl-37858593

RESUMO

The impact of procedural volume on transcatheter aortic valve replacement (TAVR) outcomes in Japan remains uncertain. Japan has carefully introduced TAVR after the establishment of techniques in Western countries and therefore may not exhibit volume-outcome relations after TAVR. Data on transfemoral TAVR was collected from the Japan Transcatheter Valve Therapy (J-TVT) registry between 2018 and 2020. Hospitals were categorized into quartiles (lowest, lower, high, and highest) based on annual TAVR volume. The primary analysis compared 30-day mortality among different TAVR volume hospitals. A multivariable adjustment analysis was performed to calculate the adjusted odds ratio (aOR) and 95% confidence intervals (CIs) of 30-day all-cause mortality with highest-volume hospital as the reference. A total of 2,741 transfemoral TAVR cases from 172 hospitals were included in the analysis. Median hospital TAVR volume was 38 (interquartile range 27 to 60) per year. Unadjusted 30-day mortality was 0.46%, 0.69%, 1.17%, and 1.18% from the lowest to the highest quartile of hospitals, respectively. There was no significant difference in 30-day mortality rates for lowest-volume hospitals (aOR 0.51, 95% CI 0.24 to 1.05, p = 0.07), low-volume hospitals (aOR 0.76, 95% CI 0.46 to 1.26, p = 0.29), or high-volume hospitals (aOR 1.11, 95% CI 0.74 to 1.67, p = 0.60). An analysis from the contemporary national registry in Japan did not find an obvious inverse relation between annual hospital volume and 30-day mortality. Our results suggest that TAVR has now reached a level of procedural maturity, with standardized outcomes observed across hospitals regardless of their annual procedural volume.


Assuntos
Estenose da Valva Aórtica , Substituição da Valva Aórtica Transcateter , Humanos , Substituição da Valva Aórtica Transcateter/métodos , Estenose da Valva Aórtica/cirurgia , População do Leste Asiático , Sistema de Registros , Hospitais com Alto Volume de Atendimentos , Resultado do Tratamento , Valva Aórtica/cirurgia , Fatores de Risco
18.
Cardiovasc Interv Ther ; 38(4): 388-394, 2023 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-37185925

RESUMO

In-hospital mortality following percutaneous coronary intervention (PCI) varies across institutions with different annual PCI volumes. The failure to rescue (FTR) rate, defined as the mortality rate following PCI-related complications, may account for the volume-outcome relationship. The Japanese Nationwide PCI Registry, a consecutive, nationally mandated registry between 2019 and 2020, was queried. The FTR rate is defined as 'the number of patients who died following PCI-related complications' divided by 'the number of patients who experienced at least one PCI-related complication.' Multivariate analysis was used to calculate the risk-adjusted odds ratio (aOR) of the FTR rates among hospitals stratified into tertiles as low (≤ 236/year), medium (237-405/year), and high (≥ 406/year). A total of 465,716 PCIs and 1007 institutions were included. A volume-outcome relationship was observed for in-hospital mortality, and the medium-volume (aOR 0.90, 95% confidence interval [CI] 0.85-0.96), as well as high-volume (aOR 0.84, 95% CI 0.79-0.89) hospitals, had significantly lower in-hospital mortality than low-volume hospitals. Complication rates were lower at high-volume centers (1.9%, 2.2%, and 2.6% for high-, medium-, and low-volume centers, respectively; p < 0.001). The overall FTR rate was 19.0%. The FTR rates for the low-, medium-, and high-volume hospitals were 19.3%, 17.7%, and 20.6%, respectively. The medium-volume hospitals had a lower FTR rate (aOR 0.82, 95% [CI] 0.68-0.99), whereas the FTR rate was similar at the high-volume hospitals compared with that of the low-volume hospitals (aOR 1.02, 95% CI 0.83-1.26). In-hospital mortality was low after PCI in high-volume hospitals. However, the FTR rate in high-volume hospitals was not necessarily lower than that in low-volume hospitals. The FTR rate did not account for the volume-outcome relationship in PCI.


Assuntos
Intervenção Coronária Percutânea , Complicações Pós-Operatórias , Humanos , Complicações Pós-Operatórias/epidemiologia , Intervenção Coronária Percutânea/efeitos adversos , População do Leste Asiático , Mortalidade Hospitalar , Sistema de Registros
19.
EuroIntervention ; 17(17): e1435-e1444, 2022 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-34483092

RESUMO

BACKGROUND: An inferoposterior transseptal puncture (TSP) is generally recommended for percutaneous left atrial appendage (LAA) closure. However, the LAA is a highly variable anatomical structure. This may have an impact on the preferred TSP site. AIMS: This study aimed to determine the optimal TSP site for percutaneous LAA closure in different LAA morphologies. METHODS: In this prospective study, 182 patients undergoing percutaneous LAA closure were included. The spatial relationship of the LAA to the fossa ovalis and its consequence for TSP was assessed at preprocedural cardiac computed tomography (CCT). RESULTS: Based on CCT analysis, it was predicted that coaxial alignment between the delivery sheath and the LAA would be obtained by an inferoposterior, inferocentral, or inferoanterior TSP in 75%, 16% and 8% of cases, respectively. This was also confirmed by procedural LAA angiogram in 175 cases (96%) with <30° angle between the delivery sheath and the LAA central axis. Multivariate logistic regression analysis identified reverse chicken wing LAA (odds ratio [OR] 6.36 [1.85-29.3]; p=0.005) and posterior bending of the proximal LAA (OR 17.2 [3.3-96.2]; p<0.001) as independent predictors of a central or anterior TSP - this to increase the chance of obtaining coaxial alignment between the delivery sheath and the LAA. CONCLUSIONS: An inferoposterior TSP is recommended in the majority of percutaneous LAA closure procedures in order to obtain coaxial alignment between the delivery sheath and the LAA. An inferior but more central/anterior TSP should be recommended in case of a reverse chicken wing LAA or posterior bending of the proximal LAA, which occurs in 20-25% of cases.


Assuntos
Apêndice Atrial , Fibrilação Atrial , Apêndice Atrial/diagnóstico por imagem , Apêndice Atrial/cirurgia , Fibrilação Atrial/cirurgia , Cateterismo Cardíaco , Ecocardiografia Transesofagiana , Humanos , Estudos Prospectivos , Punções , Tomografia Computadorizada por Raios X , Resultado do Tratamento
20.
J Arrhythm ; 37(6): 1488-1496, 2021 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-34887953

RESUMO

BACKGROUND: Exposure to radiation during catheter ablation procedures poses a risk to the heath of both the patient and electrophysiology laboratory staff. Recently, the feasibility and effectiveness of zero-fluoroscopy ablation have been reported. However, studies on the outcomes of zero-fluoroscopy ablation in Japan remain limited. This study investigated the outcomes of zero-fluoroscopy ablation for cardiac arrhythmias at a Japanese institute. METHODS AND RESULTS: We present a retrospective analysis of the safety, efficacy, and feasibility data from 221 consecutive patients who underwent zero-fluoroscopy ablation. Of these patients, 181 had atrial fibrillation, 17 had paroxysmal supraventricular tachycardia, 13 had atrial tachycardia, 6 had ventricular tachycardia, and 4 had ventricular premature contractions. We performed zero-fluoroscopy ablation using three-dimensional electro-anatomical mapping systems and intracardiac echocardiography imaging. Ultrasound-guided sheath insertion was performed on all cases. Our experience includes exclusively endocardial cardiac ablations. The mean follow-up was 24 months. The recurrence rates were 25.4% for atrial fibrillation, 5.9% for paroxysmal supraventricular tachycardia, 15.4% for atrial tachycardia, 33.3% for ventricular tachycardia, and 25% for ventricular premature contraction. Complications occurred in two patients (0.9%), and there was no occurrence of death. A fluoroscopic guide was used in three cases for the confirmation of vascular access (one case) and for complications (two cases). CONCLUSIONS: Zero-fluoroscopy ablation was routinely performed without compromising on safety and efficacy. This approach may eliminate the exposure to radiation for all individuals involved in this procedure.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA