Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 83
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
Pacing Clin Electrophysiol ; 47(1): 121-123, 2024 01.
Artigo em Inglês | MEDLINE | ID: mdl-38055567

RESUMO

Cardiac resynchronization therapy (CRT) is an established treatment for heart failure patients with left ventricular dysfunction and a left bundle branch block. However, its impact on right ventricular (RV) function remains uncertain. This cardiac magnetic resonance imaging study found that CRT did not improve RV volumes and function, and CRT-off during follow-up had an immediate detrimental effect on the RV, which may suggest potential unfavorable RV remodeling with RV pacing during CRT.


Assuntos
Terapia de Ressincronização Cardíaca , Insuficiência Cardíaca , Humanos , Terapia de Ressincronização Cardíaca/métodos , Bloqueio de Ramo/terapia , Ventrículos do Coração/diagnóstico por imagem , Resultado do Tratamento , Insuficiência Cardíaca/terapia , Função Ventricular Esquerda , Eletrocardiografia/métodos
2.
Europace ; 25(9)2023 08 02.
Artigo em Inglês | MEDLINE | ID: mdl-37421339

RESUMO

AIMS: Substrate assessment of scar-mediated ventricular tachycardia (VT) is frequently performed using late gadolinium enhancement (LGE) images. Although this provides structural information about critical pathways through the scar, assessing the vulnerability of these pathways for sustaining VT is not possible with imaging alone.This study evaluated the performance of a novel automated re-entrant pathway finding algorithm to non-invasively predict VT circuit and inducibility. METHODS: Twenty post-infarct VT-ablation patients were included for retrospective analysis. Commercially available software (ADAS3D left ventricular) was used to generate scar maps from 2D-LGE images using the default 40-60 pixel-signal-intensity (PSI) threshold. In addition, algorithm sensitivity for altered thresholds was explored using PSI 45-55, 35-65, and 30-70. Simulations were performed on the Virtual Induction and Treatment of Arrhythmias (VITA) framework to identify potential sites of block and assess their vulnerability depending on the automatically computed round-trip-time (RTT). Metrics, indicative of substrate complexity, were correlated with VT-recurrence during follow-up. RESULTS: Total VTs (85 ± 43 vs. 42 ± 27) and unique VTs (9 ± 4 vs. 5 ± 4) were significantly higher in patients with- compared to patients without recurrence, and were predictive of recurrence with area under the curve of 0.820 and 0.770, respectively. VITA was robust to scar threshold variations with no significant impact on total and unique VTs, and mean RTT between the four models. Simulation metrics derived from PSI 45-55 model had the highest number of parameters predictive for post-ablation VT-recurrence. CONCLUSION: Advanced computational metrics can non-invasively and robustly assess VT substrate complexity, which may aid personalized clinical planning and decision-making in the treatment of post-infarction VT.


Assuntos
Cicatriz , Simulação por Computador , Taquicardia Ventricular , Humanos , Algoritmos , Ablação por Cateter , Cicatriz/complicações , Infarto do Miocárdio/complicações , Estudos Retrospectivos , Taquicardia Ventricular/etiologia , Taquicardia Ventricular/cirurgia , Reprodutibilidade dos Testes , Masculino , Pessoa de Meia-Idade , Idoso , Idoso de 80 Anos ou mais
3.
BMC Cardiovasc Disord ; 23(1): 621, 2023 12 19.
Artigo em Inglês | MEDLINE | ID: mdl-38114911

RESUMO

BACKGROUND: Conduction system pacing (CSP) is a novel technique that involves pacing the His-Purkinje system instead of the traditional right ventricular (RV) apex. This technique aims to avoid the adverse effects of RV apical pacing, which can lead to ventricular dyssynchrony and heart failure over time. CSP is gaining popularity but its long-term efficacy and challenges remain uncertain. This report discusses a case where CSP was initially successful but faced complications due to an increasing pacing threshold. CASE PRESENTATION: A 65-year-old female with total atrioventricular block was referred for brady-pacing. Due to the potential for chronic RV pacing, CSP was chosen. The CSP implantation involved subcutaneous device placement, with a CSP lead in the left bundle branch area (LBBA) and an RV backup lead. A year after successful implantation, the LBBA pacing threshold progressively increased. Subsequent efforts to correct it led to anodal capture and battery depletion. Cardiac magnetic resonance imaging (CMR) revealed mid-septal fibrosis at the area of LBBA lead placement and suggested cardiac sarcoidosis as a possible cause. CONCLUSION: CSP is a promising technique for treating bradyarrhythmias, but this case underscores the need for vigilance in monitoring pacing thresholds. Increasing thresholds can render CSP ineffective, necessitating alternative pacing methods. The CMR findings of mid-septal fibrosis and the potential diagnosis of cardiac sarcoidosis emphasize the importance of pre-implantation assessment, as CSP may be compromised by underlying structural abnormalities. This report highlights the complexities of pacing strategy selection and the significance of comprehensive evaluation before adopting CSP.


Assuntos
Marca-Passo Artificial , Sarcoidose , Feminino , Humanos , Idoso , Estimulação Cardíaca Artificial/efeitos adversos , Estimulação Cardíaca Artificial/métodos , Sistema de Condução Cardíaco , Doença do Sistema de Condução Cardíaco , Fibrose , Eletrocardiografia , Fascículo Atrioventricular , Resultado do Tratamento
4.
J Cardiovasc Magn Reson ; 23(1): 131, 2021 11 11.
Artigo em Inglês | MEDLINE | ID: mdl-34758820

RESUMO

BACKGROUND: Atrial fibrillation (AF) is associated with profound structural and functional changes in the atria. In the present study, we investigated the association between left atrial (LA) phasic function and the extent of LA fibrosis using advanced cardiovascular magnetic resonance (CMR) imaging techniques, including 3-dimensional (3D) late gadolinium enhancement (LGE) and feature tracking. METHODS: Patients with paroxysmal and persistent AF (n = 105) underwent CMR in sinus rhythm. LA global reservoir strain, conduit strain and contractile strain were derived from cine CMR images using CMR feature tracking. The extent of LA fibrosis was assessed from 3D LGE images. Healthy subjects underwent CMR and served as controls (n = 19). RESULTS: Significantly lower LA reservoir strain, conduit strain and contractile strain were found in AF patients, as compared to healthy controls (- 15.9 ± 3.8% vs. - 21.1 ± 3.6% P < 0.001, - 8.7 ± 2.7% vs. - 12.6 ± 2.5% P < 0.001 and - 7.2 ± 2.3% vs. - 8.6 ± 2.2% P = 0.02, respectively). Patients with a high degree of LA fibrosis (dichotomized by the median value) had lower reservoir strain and conduit strain compared to patients with a low degree of LA fibrosis (- 15.0 ± 3.9% vs. - 16.9 ± 3.3%, P = 0.02 and - 7.9 ± 2.7% vs. - 9.5 ± 2.6%, P = 0.01, respectively). In contrast, no difference was found for LA contractile strain (- 7.1 ± 2.4% vs. - 7.4 ± 2.3%, P = 0.55). CONCLUSIONS: Impaired LA reservoir and conduit strain are present in AF patients with extensive atrial fibrosis. Future studies are needed to examine the biologic nature of this association and possible therapeutic implications.


Assuntos
Fibrilação Atrial , Fibrilação Atrial/diagnóstico por imagem , Meios de Contraste , Fibrose , Gadolínio , Humanos , Valor Preditivo dos Testes
5.
J Cardiovasc Electrophysiol ; 31(7): 1616-1627, 2020 07.
Artigo em Inglês | MEDLINE | ID: mdl-32406138

RESUMO

BACKGROUND: During pulmonary vein isolation (PVI), nonisolation after initial encircling of the pulmonary veins (PVs) may be due to gaps in the initial ablation line, or alternatively, earliest PV activation may occur on the intervenous carina and ablation within the wide-area circumferential ablation (WACA) circle is needed to eliminate residual conduction. This study investigated prognostic implications and predictors of gap-related persistent conduction (gap-RPC) and carina-related persistent conduction (carina-RPC) during PVI. METHODS AND RESULTS: Two hundred fourteen atrial fibrillation (AF) patients (57% paroxysmal, 61% male, mean age 62 ± 9 years) undergoing first contact force-guided radiofrequency PVI were studied. Preprocedural cardiac computed tomography imaging was used to assess left atrial and PV anatomy. PVI was assessed directly after initial WACA circle creation, after a minimum waiting period of 30 minutes, and after adenosine infusion. Persistent conduction was targeted for additional ablation and classified as gap-RPC or carina-RPC, depending on the earliest activation site. The 1-year AF recurrence rate was higher in patients with gap-RPC (47%) compared to patients without gap-RPC (28%; P = .003). No significant difference in 1-year recurrence rate was found between patients with carina-RPC (37%) and patients without carina-RPC (31%; P = .379). Multivariate analyses identified paroxysmal AF and WACA circumference as independent predictors of gap-RPC, whereas carina width and WACA circumference correlated with carina-RPC. CONCLUSIONS: Gap-RPC is associated with increased AF recurrence risk after PVI, whereas carina-RPC does not predict AF recurrence. Moreover, gap-RPC and carina-RPC have different correlates and may thus have different underlying mechanisms.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Veias Pulmonares , Idoso , Fibrilação Atrial/diagnóstico por imagem , Fibrilação Atrial/cirurgia , Ablação por Cateter/efeitos adversos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Veias Pulmonares/diagnóstico por imagem , Veias Pulmonares/cirurgia , Recidiva , Resultado do Tratamento
6.
Eur J Nucl Med Mol Imaging ; 47(7): 1688-1697, 2020 07.
Artigo em Inglês | MEDLINE | ID: mdl-31822958

RESUMO

PURPOSE: To compare cardiac magnetic resonance imaging (CMR) with [15O]H2O positron emission tomography (PET) for quantification of absolute myocardial blood flow (MBF) and myocardial flow reserve (MFR) in patients with coronary artery disease (CAD). METHODS: Fifty-nine patients with stable CAD underwent CMR and [15O]H2O PET. The CMR imaging protocol included late gadolinium enhancement to rule out presence of scar tissue and perfusion imaging using a dual sequence, single bolus technique. Absolute MBF was determined for the three main vascular territories at rest and during vasodilator stress. RESULTS: CMR measurements of regional stress MBF and MFR showed only moderate correlation to those obtained using PET (r = 0.39; P < 0.001 for stress MBF and r = 0.36; P < 0.001 for MFR). Bland-Altman analysis revealed a significant bias of 0.2 ± 1.0 mL/min/g for stress MBF and - 0.5 ± 1.2 for MFR. CMR-derived stress MBF and MFR demonstrated area under the curves of respectively 0.72 (95% CI: 0.65 to 0.79) and 0.76 (95% CI: 0.69 to 0.83) and had optimal cutoff values of 2.35 mL/min/g and 2.25 for detecting abnormal myocardial perfusion, defined as [15O]H2O PET-derived stress MBF ≤ 2.3 mL/min/g and MFR ≤ 2.5. Using these cutoff values, CMR and PET were concordant in 137 (77%) vascular territories for stress MBF and 135 (80%) vascular territories for MFR. CONCLUSION: CMR measurements of stress MBF and MFR showed modest agreement to those obtained with [15O]H2O PET. Nevertheless, stress MBF and MFR were concordant between CMR and [15O]H2O PET in 77% and 80% of vascular territories, respectively.


Assuntos
Doença da Artéria Coronariana , Circulação Coronária , Espectroscopia de Ressonância Magnética , Imagem de Perfusão do Miocárdio , Tomografia por Emissão de Pósitrons , Idoso , Meios de Contraste , Doença da Artéria Coronariana/diagnóstico por imagem , Feminino , Reserva Fracionada de Fluxo Miocárdico , Gadolínio , Humanos , Espectroscopia de Ressonância Magnética/normas , Masculino , Pessoa de Meia-Idade , Imagem de Perfusão do Miocárdio/normas , Radioisótopos de Oxigênio , Tomografia por Emissão de Pósitrons/normas , Reprodutibilidade dos Testes
7.
Eur Heart J ; 40(28): 2350-2359, 2019 07 21.
Artigo em Inglês | MEDLINE | ID: mdl-31327012

RESUMO

AIMS: Continuous thermodilution is a novel technique to quantify absolute coronary flow and microvascular resistance (MVR). Notably, intracoronary infusion of saline elicits maximal hyperaemia, obviating the need for adenosine. The primary aim of this study was to validate continuous thermodilution in humans by comparing invasive measurements to [15O]H2O positron emission tomography (PET). As a secondary goal, absolute flow and MVR were compared between invasive measurements obtained with and without adenosine. METHODS AND RESULTS: Twenty-five patients underwent coronary computed tomography angiography (CCTA), [15O]H2O PET, and invasive assessment. Absolute coronary flow and MVR were measured in the left anterior descending and left circumflex artery using a dedicated infusion catheter and a temperature/pressure sensor-tipped guidewire. Invasive measurements were performed with and without adenosine. In order to compare invasive flow measurements with PET perfusion, subtending myocardial mass of the investigated vessels was derived from CCTA using the Voronoi algorithm. Invasive and non-invasive measurements of adenosine-induced hyperaemic flow and MVR showed strong correlation (r = 0.91; P < 0.001 for flow and r = 0.85; P < 0.001 for MVR) and good agreement [intraclass correlation coefficient (ICC) = 0.90; P < 0.001 for flow and ICC = 0.79; P < 0.001 for MVR]. Absolute flow and MVR also correlated well between measurements with and without adenosine (r = 0.97; P < 0.001 for flow and r = 0.98; P < 0.001 for MVR) and showed good agreement (ICC = 0.96; P < 0.001 for flow and ICC = 0.98; P < 0.001 for MVR). CONCLUSIONS: Continuous thermodilution is an accurate method to measure absolute coronary flow and MVR, which is evidenced by strong agreement with [15O]H2O PET derived flow and resistance. Absolute flow and MVR correlate highly between invasive measurements obtained with and without adenosine, which confirms that intracoronary infusion of room temperature saline elicits steady-state maximal hyperaemia.


Assuntos
Radioisótopos de Oxigênio , Tomografia por Emissão de Pósitrons/métodos , Termodiluição/métodos , Resistência Vascular , Idoso , Feminino , Humanos , Masculino , Microvasos , Pessoa de Meia-Idade , Estudos Prospectivos , Água
11.
J Magn Reson Imaging ; 44(4): 964-71, 2016 10.
Artigo em Inglês | MEDLINE | ID: mdl-26990922

RESUMO

PURPOSE: To develop feature tracking (FT) software to perform strain analysis on conventional (nontagged) cardiac magnetic resonance imaging (MRI) function images. With the advent of MRI-conditional pacemaker systems, effects of cardiac pacing on myocardial strain can be studied using MR. In this study the impact of pacing on left ventricular (LV) strain was investigated using MR-FT in patients with an MRI-conditional cardiac implantable electronic device (CIED). MATERIALS AND METHODS: FT was performed on 32 1.5T MR studies (16 patients with an MRI-conditional CIED and 16 control patients with normal scans). Short- and long-axis steady state free precession (SSFP) cines were used for the FT analysis. Strain was assessed using CVI(42) software (Circle Cardiovascular Imaging, Alberta, Canada). In addition, the intra- and interobserver variability was determined using the intraclass correlation coefficient. RESULTS: Of the 16 patients with an MRI-conditional CIED, five patients were paced during the MRI exam. Despite the occasional presence of susceptibility artifacts induced by the CIED, radial, circumferential, and longitudinal strain parameters could be derived for all patients. Peak radial strain and peak circumferential strain were reduced during pacing when compared to the control group; for radial strain: 20.1 ± 4.7% vs. 33.1 ± 6.9%, P < 0.001, and for circumferential strain -7.5 ± 3.5% vs. -14.9 ± 3.2%, P < 0.05. Peak strain parameters were reproducible on an intra- and interobserver level. CONCLUSION: MR-FT is feasible in patients with an MRI-conditional CIED and can be used to quantify regional wall motion. J. MAGN. RESON. IMAGING 2016;44:964-971.


Assuntos
Estimulação Cardíaca Artificial/efeitos adversos , Técnicas de Imagem por Elasticidade/métodos , Interpretação de Imagem Assistida por Computador/métodos , Imagem Cinética por Ressonância Magnética/métodos , Disfunção Ventricular Esquerda/etiologia , Disfunção Ventricular Esquerda/fisiopatologia , Anisotropia , Estimulação Cardíaca Artificial/métodos , Módulo de Elasticidade , Estudos de Viabilidade , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Resistência ao Cisalhamento , Estresse Mecânico , Disfunção Ventricular Esquerda/diagnóstico por imagem
12.
Ann Noninvasive Electrocardiol ; 20(2): 132-9, 2015 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-25041476

RESUMO

BACKGROUND: In noninvasive imaging of cardiac excitation, the use of body surface potentials (BSP) rather than body volume potentials (BVP) has been favored due to enhanced computational efficiency and reduced modeling effort. Nowadays, increased computational power and the availability of open source software enable the calculation of BVP for clinical purposes. In order to illustrate the possible advantages of this approach, the explanatory power of BVP is investigated using a rectangular tank filled with an electrolytic conductor and a patient specific three dimensional model. METHODS: MRI images of the tank and of a patient were obtained in three orthogonal directions using a turbo spin echo MRI sequence. MRI images were segmented in three dimensional using custom written software. Gmsh software was used for mesh generation. BVP were computed using a transfer matrix and FEniCS software. RESULTS: The solution for 240,000 nodes, corresponding to a resolution of 5 mm throughout the thorax volume, was computed in 3 minutes. The tank experiment revealed that an increased electrode surface renders the position of the 4 V equipotential plane insensitive to mesh cell size and reduces simulated deviations. In the patient-specific model, the impact of assigning a different conductivity to lung tissue on the distribution of volume potentials could be visualized. CONCLUSION: Generation of high quality volume meshes and computation of BVP with a resolution of 5 mm is feasible using generally available software and hardware. Estimation of BVP may lead to an improved understanding of the genesis of BSP and sources of local inaccuracies.


Assuntos
Eletrocardiografia , Coração/fisiologia , Imageamento por Ressonância Magnética , Modelos Cardiovasculares , Humanos , Software
13.
Ann Noninvasive Electrocardiol ; 19(2): 105-13, 2014 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-24620843

RESUMO

Noninvasive imaging of cardiac excitation using body surface potential mapping (BSPM) data and inverse procedures is an emerging technique that enables estimation of myocardial depolarization and repolarization. Despite numerous reports on the possible advantages of this imaging technique, it has not yet advanced into daily clinical practice. This is mainly due to the time consuming nature of data acquisition and the complexity of the mathematics underlying the used inverse procedures. However, the popularity of this field of research has increased and noninvasive imaging of cardiac electrophysiology is considered a promising tool to complement conventional invasive electrophysiological studies. Furthermore, the use of appropriately designed electrode vests and more advanced computers has greatly reduced the procedural time. This review provides descriptive overview of the research performed thus far and the possible future directions. The general challenges in routine application of BSPM and inverse procedures are discussed. In addition, individual properties of the biophysical models underlying the inverse procedures are illustrated.


Assuntos
Mapeamento Potencial de Superfície Corporal/métodos , Humanos , Modelos Cardiovasculares
14.
Radiol Cardiothorac Imaging ; 6(2): e230172, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38573128

RESUMO

Purpose To perform a qualitative and quantitative evaluation of the novel image-navigated (iNAV) 3D late gadolinium enhancement (LGE) cardiac MRI imaging strategy in comparison with the conventional diaphragm-navigated (dNAV) 3D LGE cardiac MRI strategy for the assessment of left atrial fibrosis in atrial fibrillation (AF). Materials and Methods In this prospective study conducted between April and September 2022, 26 consecutive participants with AF (mean age, 61 ± 11 years; 19 male) underwent both iNAV and dNAV 3D LGE cardiac MRI, with equivalent spatial resolution and timing in the cardiac cycle. Participants were randomized in the acquisition order of iNAV and dNAV. Both, iNAV-LGE and dNAV-LGE images were analyzed qualitatively using a 5-point Likert scale and quantitatively (percentage of atrial fibrosis using image intensity ratio threshold 1.2), including testing for overlap in atrial fibrosis areas by calculating Dice score. Results Acquisition time of iNAV was significantly lower compared with dNAV (4.9 ± 1.1 minutes versus 12 ± 4 minutes, P < .001, respectively). There was no evidence of a difference in image quality for all prespecified criteria between iNAV and dNAV, although dNAV was the preferred image strategy in two-thirds of cases (17/26, 65%). Quantitative assessment demonstrated that mean fibrosis scores were lower for iNAV compared with dNAV (12 ± 8% versus 20 ± 12%, P < .001). Spatial correspondence between the atrial fibrosis maps was modest (Dice similarity coefficient, 0.43 ± 0.15). Conclusion iNAV-LGE acquisition in individuals with AF was more than twice as fast as dNAV acquisition but resulted in a lower atrial fibrosis score. The differences between these two strategies might impact clinical interpretation. ©RSNA, 2024.


Assuntos
Fibrilação Atrial , Diafragma , Idoso , Humanos , Masculino , Pessoa de Meia-Idade , Fibrilação Atrial/diagnóstico , Meios de Contraste , Gadolínio , Átrios do Coração/diagnóstico por imagem , Imageamento por Ressonância Magnética , Estudos Prospectivos , Feminino
15.
Heart Rhythm ; 2024 Apr 24.
Artigo em Inglês | MEDLINE | ID: mdl-38670247

RESUMO

BACKGROUND: Implantable cardiac defibrillator (ICD) implantation can protect against sudden cardiac death after myocardial infarction. However, improved risk stratification for device requirement is still needed. OBJECTIVE: The purpose of this study was to improve assessment of postinfarct ventricular electropathology and prediction of appropriate ICD therapy by combining late gadolinium enhancement (LGE) and advanced computational modeling. METHODS: ADAS 3D LV (ADAS LV Medical, Barcelona, Spain) and custom-made software were used to generate 3-dimensional patient-specific ventricular models in a prospective cohort of patients with a myocardial infarction (N = 40) having undergone LGE imaging before ICD implantation. Corridor metrics and 3-dimensional surface features were computed from LGE images. The Virtual Induction and Treatment of Arrhythmias (VITA) framework was applied to patient-specific models to comprehensively probe the vulnerability of the scar substrate to sustaining reentrant circuits. Imaging and VITA metrics, related to the numbers of induced ventricular tachycardias and their corresponding round trip times (RTTs), were compared with ICD therapy during follow-up. RESULTS: Patients with an event (n = 17) had a larger interface between healthy myocardium and scar and higher VITA metrics. Cox regression analysis demonstrated a significant independent association with an event: interface (hazard ratio [HR] 2.79; 95% confidence interval [CI] 1.44-5.44; P < .01), unique ventricular tachycardias (HR 1.67; 95% CI 1.04-2.68; P = .03), mean RTT (HR 2.14; 95% CI 1.11-4.12; P = .02), and maximum RTT (HR 2.13; 95% CI 1.19-3.81; P = .01). CONCLUSION: A detailed quantitative analysis of LGE-based scar maps, combined with advanced computational modeling, can accurately predict ICD therapy and could facilitate the early identification of high-risk patients in addition to left ventricular ejection fraction.

16.
Int J Cardiol ; 378: 23-31, 2023 05 01.
Artigo em Inglês | MEDLINE | ID: mdl-36804765

RESUMO

PURPOSE: The present study assesses different left atrial (LA) strain approaches in relation to atrial fibrillation (AF) recurrence after ablation and compares LA feature tracking (FT) strain to novel rapid LA strain approaches in AF patients. METHODS: This retrospective single-center study comprised of 110 prospectively recruited AF patients who underwent cardiac magnetic resonance (CMR) imaging in sinus rhythm prior to their first pulmonary vein isolation ablation. LA rapid strain (long axis strain and atrioventricular (AV)-junction strain), LA FT strain, and LA volumes were derived from 2-chamber and 4-chamber cine images. AF recurrence was followed up for 12 months using either 12­lead ECGs or rhythm Holter monitoring. RESULTS: Arrhythmia recurrence was observed in 39 patients (36%) after the 90-day blanking period, occurring at a median of 181 (122-286) days. LA long axis strain, AV-junction strain, and FT strain were all more impaired in patients with AF recurrence compared to patients without AF recurrence (long axis strain: P < 0.01; AV-junction strain: P < 0.001; FT strain: P < 0.01, respectively). Area under the curve (AUC) values for LA remodeling parameters in association with AF recurrence were 0.68 for long axis strain, 0.68 for AV-junction strain, 0.66 for FT strain, 0.66 for LA volume index. Phasic FT LA strain demonstrated that contractile strain had the highest AUC (0.70). CONCLUSION: Both LA rapid strain and LA FT strain are associated with arrhythmia recurrence after ablation in AF patients. LA rapid strain can be a convenient and reproducible alternative for LA FT strain to assess LA function in clinical practice.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Humanos , Fibrilação Atrial/diagnóstico por imagem , Fibrilação Atrial/cirurgia , Fibrilação Atrial/patologia , Estudos Retrospectivos , Valor Preditivo dos Testes , Átrios do Coração , Espectroscopia de Ressonância Magnética , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Recidiva
17.
Int J Cardiovasc Imaging ; 39(9): 1753-1763, 2023 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-37515682

RESUMO

PURPOSE: Left atrial (LA) sphericity is a novel, geometry-based parameter that has been used to visualize and quantify LA geometrical remodeling in patients with atrial fibrillation (AF). This study examined the association between LA sphericity, and LA longitudinal strain and strain rate measured by feature-tracking in AF patients. METHODS: 128 AF patients who underwent cardiovascular magnetic resonance (CMR) imaging in sinus rhythm prior to their pulmonary vein isolation (PVI) procedure were retrospectively analyzed. LA sphericity was calculated by segmenting the LA (excluding the pulmonary veins and the LA appendage) on a 3D contrast enhanced MR angiogram and comparing the resulting shape with a perfect sphere. LA global reservoir strain, conduit strain, contractile strain and corresponding strain rates were derived from cine images using feature-tracking. For statistical analysis, Pearson correlations, multivariable logistic regression analysis, and Student t-tests were used. RESULTS: Patients with a spherical LA (dichotomized by the median value) had a lower reservoir strain and conduit strain compared to patients with a non-spherical LA (-15.4 ± 4.2% vs. -17.1 ± 3.5%, P = 0.02 and - 8.2 ± 3.0% vs. -9.5 ± 2.6%, P = 0.01, respectively). LA strain rate during early ventricular diastole was also different between both groups (-0.7 ± 0.3s- 1 vs. -0.9 ± 0.3s- 1, P = 0.001). In contrast, no difference was found for LA contractile strain (-7.2 ± 2.6% vs. -7.6 ± 2.2%, P = 0.30). CONCLUSIONS: LA passive strain is significantly impaired in AF patients with a spherical LA, though this relation was not independent from LA volume.


Assuntos
Apêndice Atrial , Fibrilação Atrial , Remodelamento Atrial , Ablação por Cateter , Humanos , Fibrilação Atrial/diagnóstico por imagem , Fibrilação Atrial/cirurgia , Estudos Retrospectivos , Valor Preditivo dos Testes , Átrios do Coração , Ablação por Cateter/métodos
18.
Eur Heart J Cardiovasc Imaging ; 24(3): 336-345, 2023 02 17.
Artigo em Inglês | MEDLINE | ID: mdl-35921538

RESUMO

AIMS: Bi-atrial remodelling in patients with atrial fibrillation (AF) is rarely assessed and data on the presence of right atrial (RA) fibrosis, the relationship between RA and left atrial (LA) fibrosis, and possible association of RA remodelling with AF recurrence after ablation in patients with AF is limited. METHODS AND RESULTS: A total of 110 patients with AF undergoing initial pulmonary vein isolation (PVI) were included in the present study. All patients were in sinus rhythm during cardiac magnetic resonance (CMR) imaging performed prior to ablation. LA and RA volumes and function (volumetric and feature tracking strain) were derived from cine CMR images. The extent of LA and RA fibrosis was assessed from 3D late gadolinium enhancement images. AF recurrence was followed up for 12 months after PVI using either 12-lead electrocardiograms or Holter monitoring. Arrhythmia recurrence was observed in 39 patients (36%) after the 90-day blanking period, occurring at a median of 181 (interquartile range: 122-286) days. RA remodelling parameters were not significantly different between patients with and without AF recurrence after ablation, whereas LA remodelling parameters were different (volume, emptying fraction, and strain indices). LA fibrosis had a strong correlation with RA fibrosis (r = 0.88, P < 0.001). Both LA and RA fibrosis were not different between patients with and without AF recurrence. CONCLUSIONS: This study shows that RA remodelling parameters were not predictive of AF recurrence after AF ablation. Bi-atrial fibrotic remodelling is present in patients with AF and moreover, the amount of LA fibrosis had a strong correlation with the amount of RA fibrosis.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Humanos , Fibrilação Atrial/diagnóstico por imagem , Fibrilação Atrial/cirurgia , Fibrilação Atrial/patologia , Meios de Contraste , Função do Átrio Direito , Gadolínio , Átrios do Coração , Fibrose , Ablação por Cateter/métodos , Recidiva , Resultado do Tratamento
19.
JACC Clin Electrophysiol ; 9(12): 2665-2679, 2023 12.
Artigo em Inglês | MEDLINE | ID: mdl-37737780

RESUMO

Cardiac magnetic resonance (CMR) imaging is a valuable noninvasive tool for evaluating tissue response following catheter ablation of atrial tissue. This review provides an overview of the contemporary CMR strategies to visualize atrial ablation lesions in both the acute and chronic postablation stages, focusing on their strengths and limitations. Moreover, the accuracy of CMR imaging in comparison to atrial lesion histology is discussed. T2-weighted CMR imaging is sensitive to edema and tends to overestimate lesion size in the acute stage after ablation. Noncontrast agent-enhanced T1-weighted CMR imaging has the potential to provide more accurate assessment of lesions in the acute stage but may not be as effective in the chronic stage. Late gadolinium enhancement imaging can be used to detect chronic atrial scarring, which may inform repeat ablation strategies. Moreover, novel imaging strategies are being developed, but their efficacy in characterizing atrial lesions is yet to be determined. Overall, CMR imaging has the potential to provide virtual histology that aids in evaluating the efficacy and safety of catheter ablation and monitoring of postprocedural myocardial changes. However, technical factors, scanning during arrhythmia, and transmurality assessment pose challenges. Therefore, further research is needed to develop CMR strategies to visualize the ablation lesion maturation process more effectively.


Assuntos
Ablação por Cateter , Meios de Contraste , Humanos , Gadolínio , Imageamento por Ressonância Magnética/métodos , Ablação por Cateter/efeitos adversos , Espectroscopia de Ressonância Magnética
20.
J Am Heart Assoc ; 12(15): e028014, 2023 08.
Artigo em Inglês | MEDLINE | ID: mdl-37489727

RESUMO

Background Among patients with an implantable cardioverter-defibrillator, a high prevalence of atrial fibrillation (AF) is present. Identification of AF predictors in this patient group is of clinical importance to initiate appropriate preventive therapeutic measures to reduce the risk of AF-related complications. This study assesses whether cardiac magnetic resonance imaging-derived atrial characteristics are associated with AF development in patients with a dual-chamber implantable cardioverter-defibrillator or cardiac resynchronization therapy defibrillator, as detected by the cardiac implantable electronic device. Methods and Results This single-center retrospective study included 233 patients without documented AF history at the moment of device implantation (dual-chamber implantable cardioverter-defibrillator [63.5%] or cardiac resynchronization therapy defibrillator [36.5%]). All patients underwent cardiac magnetic resonance imaging before device implantation. Cardiac magnetic resonance-derived features of left atrial (LA) remodeling were evaluated in all patients. Detection of AF episodes was based on cardiac implantable electronic device interrogation. During a median follow-up of 6.1 years, a newly diagnosed AF episode was detected in 88 of the 233 (37.8%) patients with an ICD. In these patients, increased LA volumes and impaired LA function (LA emptying fraction and LA strain) were found as compared with patients without AF during follow-up. However, a significant association was only found in patients with dilated cardiomyopathy and not in patients with ischemic cardiomyopathy. Conclusions LA remodeling characteristics were associated with development of AF in patients with dilated cardiomyopathy but not patients with ischemic cardiomyopathy, suggesting different mechanisms of AF development in ischemic cardiomyopathy and dilated cardiomyopathy. Assessment of LA remodeling before device implantation might identify high-risk patients for AF.


Assuntos
Fibrilação Atrial , Cardiomiopatia Dilatada , Desfibriladores Implantáveis , Isquemia Miocárdica , Humanos , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/epidemiologia , Fibrilação Atrial/terapia , Desfibriladores Implantáveis/efeitos adversos , Estudos Retrospectivos , Cardiomiopatia Dilatada/etiologia , Isquemia Miocárdica/etiologia , Imageamento por Ressonância Magnética
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA