Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 73
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
J Card Fail ; 2024 Jun 06.
Artigo em Inglês | MEDLINE | ID: mdl-38851449

RESUMO

BACKGROUND: Prediction of outcomes remains an unmet need in candidates for LVADs. The development of right-heart failure portends an excess in mortality rates, but imaging parameters of right ventricular systolic function have failed to demonstrate a prognostic role. By integrating pulmonary pressure, right ventriculoarterial coupling could fill this gap. METHODS: The ASSIST-ICD registry was used to test right ventriculoarterial coupling as a surrogate parameter at implantation for the prediction of all-cause mortality. RESULTS: The ratio of the tricuspid annular-plane systolic excursion over the estimated systolic pulmonary pressure (TAPSE/sPAP) was not associated with long-term survival in univariate analysis (P = 0.89), nor was the pulmonary artery pulsatility index (PAPi) (P = 0.13). Conversely, the ratio of the right atrial pressure over the pulmonary capillary wedge pressure (RAP/PCWP) was associated with all-cause mortality (P < 0.01). After taking tricuspid regurgitation severity, LVAD indication, LVAD model, age, blood urea nitrogen levels, and pulmonary vascular resistance into account, RAP/PCWP remained associated with survival (HR 1.35 [1.10 - 1.65]; P < 0.01). CONCLUSION: Among pre-implant RVAC surrogates, only RAP/PCWP was associated with long-term all-cause mortality in LVAD recipients. This association was independent of established risk factors.

2.
Hum Mutat ; 43(9): 1333-1342, 2022 09.
Artigo em Inglês | MEDLINE | ID: mdl-35819174

RESUMO

Arrhythmogenic cardiomyopathy with right dominant form (ACR) is a rare heritable cardiac cardiomyopathy disorder associated with sudden cardiac death. Pathogenic variants (PVs) in desmosomal genes have been causally related to ACR in 40% of cases. Other genes encoding nondesmosomal proteins have been described in ACR, but their contribution in this pathology is still debated. A panel of 71 genes associated with inherited cardiopathies was screened in an ACR population of 172 probands and 856 individuals from the general population. PVs and uncertain significance variants (VUS) have been identified in 36% and 18.6% of patients, respectively. Among the cardiopathy-associated genes, burden tests show a significant enrichment in PV and VUS only for desmosomal genes PKP2 (plakophilin-2), DSP (desmoplakin), DSC2 (desmocollin-2), and DSG2 (desmoglein-2). Importantly, VUS may account for 15% of ACR cases and should then be considered for molecular diagnosis. Among the other genes, no evidence of enrichment was detected, suggesting an extreme caution in the interpretation of these genetic variations without associated functional or segregation data. Genotype-phenotype correlation points to (1) a more severe and earlier onset of the disease in PV and VUS carriers, underlying the importance to carry out presymptomatic diagnosis in relatives and (2) to a more prevalent left ventricular dysfunction in DSP variant carriers.


Assuntos
Displasia Arritmogênica Ventricular Direita , Displasia Arritmogênica Ventricular Direita/diagnóstico , Displasia Arritmogênica Ventricular Direita/genética , Displasia Arritmogênica Ventricular Direita/metabolismo , Desmossomos/genética , Desmossomos/metabolismo , Estudos de Associação Genética , Heterozigoto , Humanos , Placofilinas/genética , Placofilinas/metabolismo
3.
Crit Care Med ; 50(5): e426-e433, 2022 05 01.
Artigo em Inglês | MEDLINE | ID: mdl-34974497

RESUMO

OBJECTIVES: Temporary circulatory support (TCS) as a bridge-to-left ventricular assist device (BTL) in cardiogenic shock patients has been increasing, but limited data exists on this BTL strategy. We aimed at analyzing the outcome of BTL patients in a population of cardiogenic shock patients compared with those without TCS at the time of the left ventricular assist device (LVAD) surgery and identify predictors of postoperative mortality in this specific population. DESIGN: A multicenter retrospective observational study conducted in 19 centers from 2006 to 2016. SETTING: Nineteen French centers. PATIENTS: A total of 329 cardiogenic shock patients at the time of LVAD implantation were analyzed. Patients were divided in three groups: those under TCS at the time of LVAD implantation (n = 173), those with TCS removal before LVAD surgery (n = 24), and those who did not undergo a bridging strategy (n = 152). Primary endpoint was 30-day mortality. INTERVENTIONS: None. MEASUREMENTS AND MAIN RESULTS: Among the BTL group, 68 (39.3%), 18 (10.4%), and 15 (8.7%) patients were under venoarterial extracorporeal membrane oxygenation, Impella, and IABP support alone, and 72 patients (20.6%) were under multiple TCS support. BTL patients presented similar 30 days survival compared with the TCS removal and non-BTL groups. However, BTL group had a significantly longer ICU duration stay, with two-fold duration of mechanical ventilation time, but the three groups experienced similar postoperative complications. Multivariate analysis identified three independent predictors of mortality in the BTL group: combined surgery with LVAD, body mass index (BMI), and heart failure (HF) duration. BTL strategy was not an independent predictor of mortality in cardiogenic shock patients who underwent LVAD. CONCLUSIONS: BTL strategy is not associated with a lower survival among cardiogenic shock patients with LVAD implantation. Predictors of mortality are combined surgery with LVAD, higher BMI, and HF duration.


Assuntos
Oxigenação por Membrana Extracorpórea , Insuficiência Cardíaca , Coração Auxiliar , Oxigenação por Membrana Extracorpórea/efeitos adversos , Insuficiência Cardíaca/complicações , Insuficiência Cardíaca/cirurgia , Coração Auxiliar/efeitos adversos , Humanos , Estudos Retrospectivos , Choque Cardiogênico/etiologia , Choque Cardiogênico/cirurgia , Resultado do Tratamento
4.
J Cardiovasc Electrophysiol ; 32(11): 2943-2952, 2021 11.
Artigo em Inglês | MEDLINE | ID: mdl-34455655

RESUMO

INTRODUCTION: The distance from the descending aorta (DA) to the posterior wall of the left atrium (LA) is variable. We aimed to determine whether the proximity between the DA and the left inferior pulmonary vein (LIPV) ostium has an impact on biophysical parameters and cryoballoon (CB) ablation efficacy during LIPV freezing. METHODS: Patients referred for CB-ablation of atrial fibrillation (AF) in two high-volume centers were included. Cryoablation data were collected prospectively for each patient. The anatomical relationships between the LIPV and the DA (distance LIPV ostium-DA, presence of an aortic imprint on the posterior aspect of the LIPV) were then retrospectively analysed on the LA computed tomography scans realized before AF ablation. RESULTS: A total of 350 patients were included (70% men, 59.7 ± 11.5 years). The decrease in the Ostium-DA distance was significantly correlated to the increase in the time-to-isolation (TTI) (r = -.31; p = .036), with less negative temperature (r = -.11; p = .045). Similarly, the presence of an aortic imprint on the LIPV was associated with a longer TTI (p < .001). The analysis of redo procedures data shows a trend toward the presence of shorter ostium-DA distances (15.3 ± 3.29 vs. 18.1 ± 4.99, p = .15) and more frequent aortic imprints (63.6% vs. 47.5%, p = .34) in patients with LIPV reconnection as opposed to patients without reconnection in the LIPV. CONCLUSION: Our findings indicated that the DA seems to have a "radiator" effect influencing LIPV cryoablation parameters during CB-ablation. Additional studies will be needed to elucidate whether this biophysical influence has a clinical impact in LIPVs reconnections.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Criocirurgia , Veias Pulmonares , Idoso , Aorta Torácica , Fibrilação Atrial/diagnóstico por imagem , Fibrilação Atrial/cirurgia , Ablação por Cateter/efeitos adversos , Criocirurgia/efeitos adversos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Veias Pulmonares/diagnóstico por imagem , Veias Pulmonares/cirurgia , Recidiva , Estudos Retrospectivos , Resultado do Tratamento
5.
J Cardiovasc Electrophysiol ; 32(2): 515-522, 2021 02.
Artigo em Inglês | MEDLINE | ID: mdl-33270307

RESUMO

OBJECTIVES: This study sought to validate the performance of the VT-LVAD risk model in predicting late ventricular arrhythmias (VAs) in patients after left ventricular assist device (LVAD) implantation. BACKGROUND: The need for implantable cardioverter-defibrillator (ICD)-implantation in LVAD recipients is not well studied. A better selection of the patients with high risk for late VAs could lead to a more targeted ICD-implantation or replacement. METHODS: The study evaluated the performance of the VT-LVAD prognostic score (VAs prior LVAD, no ACE-inhibitor in medication, heart failure duration > 12 months, early VAs post-LVAD implantation, atrial fibrillation prior LVAD, idiopathic dilated cardiomyopathy) for the endpoint of the occurrence of late VAs in 357 LVAD patients in Heart Centre of Leipzig. RESULTS: From the initial 460 patients, 357 (age: 58 ± 10 years; left ventricular ejection fraction: 20 ± 6%; HeartWare: 50%; HeartMate III: 42%) were assigned to four risk groups according to their VT-LVAD score varying from low risk to very high risk. After 25 months, late VAs occurred in 130 patients. The VT-LVAD score was an independent predictor of late VAs (multivariate analysis; p = < .001; goodness-of-tip p = .347; odds ratio: 4.8). While there was no statistically significant difference between the low- and intermediate-risk group, risk stratification for patients with high risk and very high risk performed more accurately (pairwise comparison p = .005 and p < .001, respectively). CONCLUSIONS: The VT-LVAD score predicted accurately the occurrence of late VAs in high-risk LVAD recipients in a large external cohort of LVAD recipients supporting its utility for more targeted ICD implantations.


Assuntos
Desfibriladores Implantáveis , Insuficiência Cardíaca , Coração Auxiliar , Taquicardia Ventricular , Idoso , Arritmias Cardíacas , Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/terapia , Coração Auxiliar/efeitos adversos , Humanos , Pessoa de Meia-Idade , Estudos Retrospectivos
6.
J Cardiovasc Electrophysiol ; 32(9): 2522-2527, 2021 09.
Artigo em Inglês | MEDLINE | ID: mdl-34270153

RESUMO

BACKGROUND: Temporary transvenous pacing in critically ill patients requiring prolonged cardiac pacing is associated with a high risk of complications. We sought to evaluate the safety and efficacy of self-contained intracardiac leadless pacemaker (LPM) implantation in this population. METHODS AND RESULTS: Consecutive patients implanted with a Micra LPM during the hospitalization in an intensive care unit were retrospectively included. Inclusion criteria were: more than or equal to 1 supracaval central venous line, or a ventilation tube, or intravenous antibiotic therapy for ongoing sepsis or bacteremia. Patients with a history of the previous implantation of a pacemaker were excluded. Out of 1016 patients implanted with an LPM, 99 met the inclusion criteria. Mean age was 75 years and Charlson comorbidity index 7. LPM implantation was successfully performed in 98% of cases, with a perioperative complication rate of 5%, mainly cardiac injuries. In-hospital mortality rate was 6%. No late (>30 days) device-related complication occurred, especially no infection. CONCLUSIONS: LPM appears as an acceptable alternative to conventional temporary transvenous pacing in selected critically ill patients requiring prolonged cardiac pacing, especially regarding the risk of infection.


Assuntos
Estado Terminal , Marca-Passo Artificial , Idoso , Arritmias Cardíacas/terapia , Estimulação Cardíaca Artificial/efeitos adversos , Desenho de Equipamento , Humanos , Estudos Retrospectivos , Resultado do Tratamento
7.
Europace ; 22(3): 401-411, 2020 03 01.
Artigo em Inglês | MEDLINE | ID: mdl-31865389

RESUMO

AIMS: Up to 30% of selected heart failure patients do not benefit clinically from cardiac resynchronization therapy (CRT). Left ventricular (LV) wall thickness (WT) analysed using computed tomography (CT) has rarely been evaluated in response to CRT and mitral regurgitation (MR) improvement. We examined the association of LVWT and the ability to reverse LV remodelling and MR improvement after CRT. METHODS AND RESULTS: Fifty-four patients scheduled for CRT underwent pre-procedural CT. Reduced LVWT was defined as WT <6 mm and quantified as a percentage of total LV area. Endpoints were 6-month clinical and echocardiographic response to CRT [New York Heart Association (NYHA) class, LV ejection fraction (LVEF), LV end-diastolic volume (LVEDV), and LV end-systolic volume (LVESV)], MR improvement and 2-year major adverse cardiac events (MACE). Patients were divided into three groups according to the percentage of LVWT <6 mm area: ≤20%, 20-50%, and ≥50%. At 6 months, 75%, 71%, and 42% of the patients experienced NYHA improvement in the ≤20%, 20-50%, and ≥50% group, respectively. Additionally, ≤20% group presented higher LVEF, LVEDV, and LVESV positive response rate (86%, 59%, and 83%, respectively). Both 20-50% and ≥50% groups exhibited a lower LVEF, LVEDV, and LVESV positive response rate (52% and 42%; 47% and 45%; and 53% and 45%, respectively). Additionally, ≥25% of LVWT <6 mm inclusive of at least one papillary muscle insertion was the only predictor of lack of MR improvement. Lastly, ≥50% group experienced significantly lower 2-year MACE survival free probability. CONCLUSION: WT evaluated using CT could help to stratify the response to CRT and predict MR improvement and outcomes. CLINICAL TRIAL REGISTRATION: NCT01097733.


Assuntos
Terapia de Ressincronização Cardíaca , Insuficiência Cardíaca , Insuficiência Cardíaca/diagnóstico por imagem , Insuficiência Cardíaca/terapia , Ventrículos do Coração/diagnóstico por imagem , Humanos , Volume Sistólico , Tomografia , Resultado do Tratamento , Função Ventricular Esquerda , Remodelação Ventricular
8.
Pacing Clin Electrophysiol ; 43(11): 1309-1317, 2020 11.
Artigo em Inglês | MEDLINE | ID: mdl-32627211

RESUMO

BACKGROUND: Implantable cardioverter-defibrillator (ICD) lead dysfunction has been reported after left ventricular assist device (LVAD) implantation in limited single-center studies. We aimed at describing and characterizing the incidence of ICD lead parameters dysfunction after LVAD implantation. METHODS: Among the 652 patients enrolled in the ASSIST-ICD study, only patients with an ICD prior to LVAD were included (n = 401). ICD lead parameters dysfunction following LVAD implantation is defined as follows: (a) >50% decrease in sensing threshold, (b) pacing lead impedance increase/decrease by >100Ω, and (c) >50% increase in pacing threshold. RESULTS: One hundred twenty-two patients with an ICD prior to LVAD had available ICD interrogation reports prior and after LVAD. A total of 67 (55%) patients exhibited at least one significant lead dysfunction: 17 (15%) exhibited >50% decrease in right ventricular (RV) sensing, 51 (42%) had >100 Ω increase/decrease in RV pacing impedance, and 24 (20%) experienced >50% increase in RV pacing threshold. A total of 52 patients experienced ventricular arrhythmia during follow-up and all were successfully detected and treated by the device. All lead dysfunction could be managed conservatively. CONCLUSION: More than 50% of LVAD-recipients may experience >1 significant change in lead parameters but none had severe clinical consequences.


Assuntos
Desfibriladores Implantáveis/efeitos adversos , Eletrodos Implantados/efeitos adversos , Coração Auxiliar , Idoso , França , Humanos , Masculino , Pessoa de Meia-Idade , Falha de Prótese
9.
Curr Heart Fail Rep ; 17(4): 116-124, 2020 08.
Artigo em Inglês | MEDLINE | ID: mdl-32506301

RESUMO

PURPOSE OF THE REVIEW: Patients with cardiomyopathy and impaired left ventricular (LV) ejection fraction are at risk of sudden cardiac death (SCD). In selected heart failure patients, cardiac resynchronization therapy (CRT) provides LV reverse remodeling and improves the cellular and molecular function leading to a reduced risk of ventricular arrhythmia and SCD. Consequently, some CRT candidates may not need concomitant ICD therapy. This review aimed at focusing on the residual risk of SCD in patients receiving CRT and discussing the requirement of a concomitant ICD therapy in CRT candidates. RECENT FINDINGS: New imaging diagnostic tools may be helpful to accurately predict patient with a residual risk of SCD and who required a CRT-D implantation. Recent data highlighted that cardiac computed tomography (CT) or myocardial scar tissue analysis using contrast-enhanced cardiac magnetic resonance (CMR) was able to predict the occurrence of VA in patients with bi-ventricular pacing. Cardiac imaging and specifically myocardial scar analysis seem promising to evaluate the risk of SCD following bi-ventricular pacing and will probably be of great help in the future to accurately identify those who needs concomitant defibrillator's protection.


Assuntos
Terapia de Ressincronização Cardíaca/métodos , Cardiomiopatias/complicações , Morte Súbita Cardíaca/prevenção & controle , Desfibriladores Implantáveis , Marca-Passo Artificial , Volume Sistólico/fisiologia , Remodelação Ventricular , Cardiomiopatias/fisiopatologia , Cardiomiopatias/terapia , Morte Súbita Cardíaca/etiologia , Humanos , Função Ventricular Esquerda/fisiologia
10.
Am Heart J ; 214: 69-76, 2019 08.
Artigo em Inglês | MEDLINE | ID: mdl-31174053

RESUMO

BACKGROUND: Left ventricular assist device (LVAD)-associated infections may be life-threatening and impact patients' outcome. We aimed to identify the characteristics, risk factors, and prognosis of LVAD-associated infections. METHODS: Patients included in the ASSIST-ICD study (19 centers) were enrolled. The main outcome was the occurrence of LVAD-associated infection (driveline infection, pocket infection, or pump/cannula infection) during follow-up. RESULTS: Of the 652 patients enrolled, 201 (30.1%) presented a total of 248 LVAD infections diagnosed 6.5 months after implantation, including 171 (26.2%), 51 (7.8%), and 26 (4.0%) percutaneous driveline infection, pocket infection, or pump/cannula infection, respectively. Patients with infections were aged 58.7 years, and most received HeartMate II (82.1%) or HeartWare (13.4%). Most patients (62%) had implantable cardioverter-defibrillators (ICDs) before LVAD, and 104 (16.0%) had ICD implantation, extraction, or replacement after the LVAD surgery. Main pathogens found among the 248 infections were Staphylococcus aureus (n = 113' 45.4%), Enterobacteriaceae (n = 61; 24.6%), Pseudomonas aeruginosa (n = 34; 13.7%), coagulase-negative staphylococci (n = 13; 5.2%), and Candida species (n = 13; 5.2%). In multivariable analysis, HeartMate II (subhazard ratio, 1.56; 95% CI, 1.03 to 2.36; P = .031) and ICD-related procedures post-LVAD (subhazard ratio, 1.43; 95% CI, 1.03-1.98; P = .031) were significantly associated with LVAD infections. Infections had no detrimental impact on survival. CONCLUSIONS: Left ventricular assist device-associated infections affect one-third of LVAD recipients, mostly related to skin pathogens and gram-negative bacilli, with increased risk with HeartMate II as compared with HeartWare, and in patients who required ICD-related procedures post-LVAD. This is a plea to better select patients needing ICD implantation/replacement after LVAD implantation.


Assuntos
Infecções Relacionadas a Cateter/etiologia , Coração Auxiliar/efeitos adversos , Infecções Relacionadas à Prótese/etiologia , Infecções Relacionadas a Cateter/epidemiologia , Infecções Relacionadas a Cateter/microbiologia , Infecções Relacionadas a Cateter/mortalidade , Desfibriladores Implantáveis/estatística & dados numéricos , Remoção de Dispositivo/estatística & dados numéricos , Feminino , França/epidemiologia , Ventrículos do Coração , Coração Auxiliar/estatística & dados numéricos , Humanos , Masculino , Pessoa de Meia-Idade , Análise Multivariada , Prognóstico , Infecções Relacionadas à Prótese/epidemiologia , Infecções Relacionadas à Prótese/microbiologia , Infecções Relacionadas à Prótese/mortalidade , Estudos Retrospectivos , Fatores de Risco
11.
Europace ; 21(5): 803-809, 2019 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-30624630

RESUMO

AIMS: Ventricular tachycardia (VT) ablation has been proven to be effective and safe to avoid arrhythmia recurrences in patients with repaired congenital heart disease (CHD). However, some of these patients may present right ventricular (RV) access issues [agenesia or thrombosis of inferior vena cava (IVC)], making impossible to access the right ventricle through an inferior approach. In such patients, only a superior approach would theoretically be feasible. METHODS AND RESULTS: All VT ablations performed through a jugular or subclavian approach in CHD patients between 2012 and 2017 were included. Among 247 patients scheduled for VT ablation, two patients underwent three VT ablation procedures via a superior approach for due to the inability to access the right ventricle through a conventional IVC access (IVC interruption with azygos continuation in one patient and IVC thrombosis in the other). Ablation was performed using a three-dimensional system through a superior approach, using a subclavian access in both cases. A redo ablation had to be performed in the first patient using a jugular approach. Large curve catheters were used to facilitate RV outflow tract access. Supposed critical isthmuses could be localized and ablated. Patients remained free from arrhythmias during follow-up. CONCLUSION: In patients with repaired CHD and 'no femoral access', ablation of RV tachycardia can be performed using a subclavian or a jugular approach. Mapping may be challenging, requiring large curve catheters. Conventional isthmuses can be mapped and ablated successfully, and such patients should not be denied radiofrequency ablation.


Assuntos
Ablação por Cateter , Cateterismo Periférico , Veias Jugulares/cirurgia , Veia Subclávia/cirurgia , Taquicardia Ventricular , Adulto , Mapeamento Potencial de Superfície Corporal/métodos , Ablação por Cateter/instrumentação , Ablação por Cateter/métodos , Cateterismo Periférico/instrumentação , Cateterismo Periférico/métodos , Feminino , Cardiopatias Congênitas/cirurgia , Humanos , Masculino , Estudos Retrospectivos , Prevenção Secundária/métodos , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/prevenção & controle , Taquicardia Ventricular/cirurgia , Resultado do Tratamento
12.
Europace ; 20(7): 1115-1121, 2018 07 01.
Artigo em Inglês | MEDLINE | ID: mdl-29016748

RESUMO

Aims: Pulmonary vein isolation (PVI) using second-generation cryoballoon (CB2) is associated with improved outcomes compared with first generation (CB1). We aimed at investigating the characteristics of left and right PV reconnections after CB1 and CB2 ablations in patients with clinical recurrences requiring redo ablation. Methods and results: From 2010 to 2016, 776 patients underwent 28-mm cryoballoon PVI for symptomatic paroxysmal atrial fibrillation (AF) in 3 centres, 279 with CB1 and 497 with CB2. Among them, 94 patients (12.1%) had symptomatic AF recurrences requiring a redo ablation [43 (15.4%) CB1 and 51 (10.3%) CB2]. The benefit of CB2 over CB1 was compared for each PV. Durable PVI was confirmed in 7 CB1 (16.3%) and 14 CB2 (27.4%) patients, and 2.7 ± 2.1 and 1.4 ± 1.4 gaps per patient were found, respectively (P = 0.002). Significantly more left superior and left inferior PVs were found to be isolated in CB2 compared with CB1 group (78.4% vs. 48.8%, P = 0.005 and 78.4% vs. 46.5%, P = 0.003, respectively) while the rate of durable right superior and right inferior PVs isolation were similar (68.6% vs. 60.5%, P = 0.542 and 66.7% vs. 55.8%, P = 0.387, respectively). Significantly fewer gaps were found in left PVs in CB2 patients, while there was no significant difference for right PVs. Gaps localization was similar in both groups. Conclusion: Fewer reconnection gaps are observed during redo ablations of paroxysmal AF in patients primarily ablated with CB2. This difference is driven by less reconnection gaps observed in both left PVs, while no difference was observed for right PVs.


Assuntos
Fibrilação Atrial/cirurgia , Cateteres Cardíacos , Ablação por Cateter/instrumentação , Criocirurgia/instrumentação , Veias Pulmonares/cirurgia , Potenciais de Ação , Idoso , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/fisiopatologia , Ablação por Cateter/efeitos adversos , Criocirurgia/efeitos adversos , Desenho de Equipamento , Feminino , França , Frequência Cardíaca , Humanos , Masculino , Pessoa de Meia-Idade , Veias Pulmonares/fisiopatologia , Recidiva , Estudos Retrospectivos , Fatores de Tempo , Resultado do Tratamento
16.
Am Heart J ; 178: 161-7, 2016 08.
Artigo em Inglês | MEDLINE | ID: mdl-27502864

RESUMO

Non-vitamin K oral anticoagulants (NOACs) are currently recommended for patients with nonvalvular atrial fibrillation since the publication of the 4 major pivotal trials evaluating the efficacy and safety of factor IIa and factor Xa inhibitors. The definition of nonvalvular atrial fibrillation is unclear, varying from one trial to another and even between North American and European guidelines, which is a source of uncertainties in clinical practice. However, many patients with atrial fibrillation present signs of valvular involvement, and clarification of this term is needed to not deny NOACs to patients based on the wrong perception that they may have valvular atrial fibrillation. The currently unique contraindications to NOACs are patients with mechanical heart valves and those with moderate-to-severe mitral stenosis, as stated by the recent 2015 position paper of the European Heart Rhythm Association. Patients with native heart valve involvement, regardless of their severity, are suitable for NOAC therapy. Patients with bioprosthetic heart valves and mitral valve repair may be suitable for NOACs except for the first 3 and the first 3-6 months postoperatively, respectively. Patients with transaortic valve implantation or percutaneous transluminal aortic valvuloplasty are also considered as being eligible for NOACs, although the bleeding risk has to be carefully considered in this population often requiring a combination with antiplatelet therapy. Future studies are warranted to increase the level of evidence of use of NOACs, particularly in patients with transaortic valve implantation and valvular surgery, and to determine whether they could be used in the future in the only 2 remaining contraindications.


Assuntos
Fibrilação Atrial/classificação , Antitrombinas , Fibrilação Atrial/tratamento farmacológico , Fibrilação Atrial/etiologia , Bioprótese , Contraindicações , Inibidores do Fator Xa , Doenças das Valvas Cardíacas/complicações , Próteses Valvulares Cardíacas , Humanos , Estenose da Valva Mitral/complicações , Acidente Vascular Cerebral/etiologia , Acidente Vascular Cerebral/prevenção & controle
18.
ESC Heart Fail ; 11(4): 2100-2112, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-38581135

RESUMO

AIMS: Right ventricular failure after left ventricular assist device (LVAD) implantation is a major concern that remains challenging to predict. We sought to investigate the relationship between preoperative pulmonary artery pulsatility index (PAPi) and mortality after LVAD implantation. METHODS AND RESULTS: A retrospective analysis of the ASSIST-ICD multicentre registry allowed the assessment of PAPi before LVAD according to the formula [(systolic pulmonary artery pressure - diastolic pulmonary artery pressure)/central venous pressure]. The primary endpoint was survival at 3 months, according to the threshold value of PAPi determined by the receiver operating characteristic (ROC) curve. A multivariate analysis including demographic, echographic, haemodynamic, and biological variables was performed to identify predictive factors for 2 year mortality. One hundred seventeen patients were included from 2007 to 2021. The mean age was 58.45 years (±13.16), with 15.4% of women (sex ratio 5.5). A total of 53.4% were implanted as bridge to transplant and 43.1% as destination therapy. Post-operative right ventricular failure was observed in 57 patients (48.7%), with no significant difference between survivors and non-survivors at 1 month (odds ratio 1.59, P = 0.30). The median PAPi for the whole study population was 2.83 [interquartile range 1.63-4.69]. The threshold value of PAPi determined by the ROC curve was 2.84. Patients with PAPi ≥ 2.84 had a higher survival rate at 3 months [PAPi < 2.84: 58.1% [46.3-72.8%] vs. PAPi ≥ 2.84: 89.1% [81.1-97.7%], hazard ratio (HR) 0.08 [0.02-0.28], P < 0.01], with no significant difference after 3 months (HR 0.67 [0.17-2.67], P = 0.57). Other predictors of 2 year mortality were systemic hypertension (HR 4.22 [1.49-11.97], P < 0.01) and diabetes mellitus (HR 4.90 [1.83-13.14], P < 0.01). LVAD implantation as bridge to transplant (HR 0.18 [0.04-0.74], P = 0.02) and heart transplantation (HR 0.02 [0.00-0.18], P < 0.01) were associated with a higher survival rate at 2 years. CONCLUSIONS: Preoperative PAPi < 2.84 was associated with a higher risk of early mortality after LVAD implantation without impacting 2 year outcomes among survivors.


Assuntos
Insuficiência Cardíaca , Coração Auxiliar , Artéria Pulmonar , Humanos , Feminino , Masculino , Pessoa de Meia-Idade , Artéria Pulmonar/fisiopatologia , Estudos Retrospectivos , Insuficiência Cardíaca/fisiopatologia , Insuficiência Cardíaca/mortalidade , Fluxo Pulsátil/fisiologia , Taxa de Sobrevida/tendências , Seguimentos , Sistema de Registros , Disfunção Ventricular Direita/fisiopatologia
19.
Front Cardiovasc Med ; 10: 1111538, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37063957

RESUMO

Cardiac resynchronisation therapy (CRT) has an established role in the management of patients with heart failure, reduced left ventricular ejection fraction (LVEF < 35%) and widened QRS (>130 msec). Despite the complex pathophysiology of left ventricular (LV) dyssynchrony and the increasing evidence supporting the identification of specific electromechanical substrates that are associated with a higher probability of CRT response, the assessment of LVEF is the only imaging-derived parameter used for the selection of CRT candidates. This review aims to (1) provide an overview of the evolution of cardiac imaging for the assessment of LV dyssynchrony and its role in the selection of patients undergoing CRT; (2) highlight the main pitfalls and advantages of the application of cardiac imaging for the assessment of LV dyssynchrony; (3) provide some perspectives for clinical application and future research in this field. Conclusion: the road for a more individualized approach to resynchronization therapy delivery is open and imaging might provide important input beyond the assessment of LVEF.

20.
Circ Arrhythm Electrophysiol ; 16(3): e011354, 2023 03.
Artigo em Inglês | MEDLINE | ID: mdl-36802906

RESUMO

BACKGROUND: Recurrences of atrial fibrillation (AF) after pulmonary vein isolation (PVI) are mainly due to pulmonary vein reconnection. However, a growing number of patients have AF recurrences despite durable PVI. The optimal ablative strategy for these patients is unknown. We analyzed the impact of current ablation strategies in a large multicenter study. METHODS: Patients undergoing a redo ablation for AF and presenting durable PVI were included. The freedom from atrial arrhythmia after pulmonary vein-based, linear-based, electrogram-based, and trigger-based ablation strategies were compared. RESULTS: Between 2010 and 2020, 367 patients (67% men, 63±10 years, 44% paroxysmal) underwent a redo ablation for AF recurrences despite durable PVI at 39 centers. After durable PVI was confirmed, linear-based ablation was performed in 219 (60%) patients, electrogram-based ablation in 168 (45%) patients, trigger-based ablation in 101 (27%) patients, and pulmonary vein-based ablation in 56 (15%) patients. Seven patients (2%) did not undergo any additional ablation during the redo procedure. After 22±19 months of follow-up, 122 (33%) and 159 (43%) patients had a recurrence of atrial arrhythmia at 12 and 24 months, respectively. No significant difference in arrhythmia-free survival was observed between the different ablation strategies. Left atrial dilatation was the only independent factor associated with arrhythmia-free survival (HR, 1.59 [95% CI, 1.13-2.23]; P=0.006). CONCLUSIONS: In patients with recurrent AF despite durable PVI, no ablation strategy used alone or in combination during the redo procedure appears to be superior in improving arrhythmia-free survival. Left atrial size is a significant predictor of ablation outcome in this population.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Veias Pulmonares , Masculino , Humanos , Feminino , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Veias Pulmonares/cirurgia , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Átrios do Coração , Reoperação/métodos , Recidiva , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA