Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 9 de 9
Filtrar
1.
J Foot Ankle Surg ; 59(4): 664-672, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32600559

RESUMO

Osteoporosis and osteoarthritis are common pathological problems of the human bone tissue. There are some cases of pilon fractures associated with these 2 pathological conditions. In terms of treatment, for a normal and healthy bone with pilon fracture, the use of the Delta external fixator is a favorable option because it can allow early mobilization for patients and provide stability for the healing process. However, the stability of the external fixator differs when there is low bone stiffness, which has not been previously investigated. Therefore, this study was conducted to determine the stability of the external fixator to treat pilon fracture associated with osteoporosis and osteoarthritis, particularly to differentiate the stress distribution and micromovement of fracture fragment. Three-dimensional finite element models of the ankle and foot bones were reconstructed based on the computed tomography datasets. The bones consisted of 5 metatarsal, 3 cuneiform, and 1 each of cuboid, navicular, calcaneus, talus, fibula, and tibia bones. They were assigned with linear isotropic behavior. The ankle joint consisted of ligament and cartilage, and they were assigned with the use of linear links and the Mooney-Rivlin model, respectively. During simulation of the gait cycle, 70 N and 350 N were applied axially to the tibia bone to represent the swing and stance phases, respectively. The metatarsal and calcaneus bones were fixed to prevent any movement of the rigid body. The study found that the greatest von Mises stress value was observed at the pin-bone interface for the osteoporosis (108 MPa) model, followed by the osteoarthritis (87 MPa) and normal (44 MPa) models, during the stance phase. For micromovement, the osteoporosis model had the largest value at 0.26 mm, followed by the osteoarthritis (0.09 mm) and normal (0.03 mm) models. In conclusion, the greatest magnitudes of stress and micromovement were observed for the osteoporosis bone and extra care should be taken to treat pilon fracture associated with this pathological condition.


Assuntos
Fraturas do Tornozelo , Fraturas da Tíbia , Fixadores Externos , Análise de Elementos Finitos , Humanos , Tíbia , Fraturas da Tíbia/diagnóstico por imagem , Fraturas da Tíbia/cirurgia
2.
ScientificWorldJournal ; 2014: 294104, 2014.
Artigo em Inglês | MEDLINE | ID: mdl-24977191

RESUMO

Well-defined image can assist user to identify region of interest during segmentation. However, complex medical image is usually characterized by poor tissue contrast and low background luminance. The contrast improvement can lift image visual quality, but the fundamental contrast enhancement methods often overlook the sudden jump problem. In this work, the proposed bihistogram Bezier curve contrast enhancement introduces the concept of "adequate contrast enhancement" to overcome sudden jump problem in knee magnetic resonance image. Since every image produces its own intensity distribution, the adequate contrast enhancement checks on the image's maximum intensity distortion and uses intensity discrepancy reduction to generate Bezier transform curve. The proposed method improves tissue contrast and preserves pertinent knee features without compromising natural image appearance. Besides, statistical results from Fisher's Least Significant Difference test and the Duncan test have consistently indicated that the proposed method outperforms fundamental contrast enhancement methods to exalt image visual quality. As the study is limited to relatively small image database, future works will include a larger dataset with osteoarthritic images to assess the clinical effectiveness of the proposed method to facilitate the image inspection.


Assuntos
Algoritmos , Aumento da Imagem/métodos , Interpretação de Imagem Assistida por Computador/métodos , Imageamento por Ressonância Magnética/métodos , Osteoartrite do Joelho/patologia , Interpretação Estatística de Dados , Humanos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
3.
Heliyon ; 10(4): e26660, 2024 Feb 29.
Artigo em Inglês | MEDLINE | ID: mdl-38404809

RESUMO

Previous works had successfully demonstrated the clinical effectiveness of unilateral external fixator in treating various types of fracture, ranging from the simple type, such as oblique and transverse fractures, to complex fractures. However, literature that investigated its biomechanical analyses to further justify its efficacy is limited. Therefore, this paper aimed to analyse the stability of unilateral external fixator for treating different types of fracture, including the simple oblique, AO32C3 comminuted, and 20 mm gap transverse fracture. These fractures were reconstructed at the distal diaphysis of the femoral bone and computationally analysed through the finite element method under the stance phase condition. Findings showed a decrease in the fixation stiffness in large gap fracture (645.2 Nmm-1 for oblique and comminuted, while 23.4 Nmm-1 for the gap fracture), which resulted in higher displacement, IFM and stress distribution at the pin bone interface. These unfavourable conditions could consequently increase the risk of delayed union, pin loosening and infection, as well as implant failure. Nevertheless, the stress observed on the fracture surfaces was relatively low and in controlled amount, indicating that bone unity is still allowable in all models. Briefly, the unilateral fixation may provide desirable results in smaller fracture gap, but its usage in larger gap fracture might be alarming. These findings could serve as a guide and insight for surgeons and researchers, especially on the biomechanical stability of fixation in different fracture types and how will it affect bone unity.

4.
Materials (Basel) ; 16(9)2023 Apr 22.
Artigo em Inglês | MEDLINE | ID: mdl-37176180

RESUMO

Total hip arthroplasty (THA) is most likely one of the most successful surgical procedures in medicine. It is estimated that three in four patients live beyond the first post-operative year, so appropriate surgery is needed to alleviate an otherwise long-standing suboptimal functional level. However, research has shown that during a complete THA procedure, a solid hip implant inserted in the femur can damage the main arterial supply of the cortex and damage the medullary space, leading to cortical bone resorption. Therefore, this study aimed to design a porous hip implant with a focus on providing more space for better osteointegration, improving the medullary revascularisation and blood circulation of patients. Based on a review of the literature, a lightweight implant design was developed by applying topology optimisation and changing the materials of the implant. Gyroid and Voronoi lattice structures and a solid hip implant (as a control) were designed. In total, three designs of hip implants were constructed by using SolidWorks and nTopology software version 2.31. Point loads were applied at the x, y and z-axis to imitate the stance phase condition. The forces represented were x = 320 N, y = -170 N, and z = -2850 N. The materials that were used in this study were titanium alloys. All of the designs were then simulated by using Marc Mentat software version 2020 (MSC Software Corporation, Munich, Germany) via a finite element method. Analysis of the study on topology optimisation demonstrated that the Voronoi lattice structure yielded the lowest von Mises stress and displacement values, at 313.96 MPa and 1.50 mm, respectively, with titanium alloys as the materials. The results also indicate that porous hip implants have the potential to be implemented for hip implant replacement, whereby the mechanical integrity is still preserved. This result will not only help orthopaedic surgeons to justify the design choices, but could also provide new insights for future studies in biomechanics.

5.
Sports Biomech ; : 1-22, 2022 Jun 20.
Artigo em Inglês | MEDLINE | ID: mdl-35722740

RESUMO

Previous research has reported that up to 92% of injuries amongst badminton players consist of lower limb, whereby 35% of foot fractures occurred at the metatarsal bone. In sports, insoles are widely used to increase athletes' performance and prevent many injuries. However, there is still a lack of badminton insole analysis and improvements. Therefore, this study aimed to biomechanically analyse three different insole designs. A validated and converged three-dimensional (3D) finite element model of ankle-foot complex was developed, which consisted of the skin, talus, calcaneus, navicular, three cuneiform, cuboid, five metatarsals and five phalanges. Three existing insoles from the market, (1) Yonex Active Pro Truactive, (2) Victor VT-XD 8 and (3) Li-Ning L6200LA, were scanned using a 3D scanner. For the analysis, single-leg landing was simulated. On the superior surface of the skin, 2.57 times of the bodyweight was axially applied, and the inferior surface of the outsole was fixed. The results showed that Insole 3 was the most optimum design to reduce peak stress on the metatarsals (3.807 MPa). In conclusion, the optimum design of Insole 3, based on the finite element analysis, could be a justification of athletes' choices to prevent injury and other complications.

6.
Injury ; 53(7): 2424-2436, 2022 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-35641332

RESUMO

For anterior cruciate ligament reconstruction (ACL-R), one of the crucial aspects of treatment is the fixator selection that could provide initial graft fixation post-operatively. Literature on biomechanical stabilities of different sizes of fixators as femoral graft fixation is limited. Therefore, this study aims to analyse the influence of different diameters of cross-pins on the stability of graft fixations after ACL-R via finite element analysis (FEA). In the methodology, three-dimensional (3D) models of three different diameters of cross-pins were developed, of which anterior tibial loads (ATL) were applied onto the tibia. From the findings, the cross-pin with a smaller diameter (4 mm) provided optimum stability than larger diameter cross-pins, whereby it demonstrated acceptable stresses at the fixators (both cross-pin and interference screw) with a different percentage of 28%, while the stresses at the corresponding bones were favourable for osseointegration to occur. Besides, the strains of the knee joint with 4 mm diameter cross-pin were also superior in providing a good biomechanical environment for bone healing, while the recorded strain values at fixators were comparable with a larger diameter of cross-pins without being inferior in terms of deformation. To conclude, the cross-pin with 4 mm diameter depicted the best biomechanical aspects in graft fixation for ACL-R since it allows better assistance for the osseointegration process and can minimise the possibility of the breakage and migration of fixators. This study is not only useful for medical surgeons to justify their choices of pin diameter to treat patients, but also for researchers to conduct future studies.


Assuntos
Lesões do Ligamento Cruzado Anterior , Reconstrução do Ligamento Cruzado Anterior , Ligamento Cruzado Anterior/cirurgia , Lesões do Ligamento Cruzado Anterior/cirurgia , Reconstrução do Ligamento Cruzado Anterior/métodos , Fenômenos Biomecânicos , Pinos Ortopédicos , Análise de Elementos Finitos , Humanos , Articulação do Joelho/cirurgia , Tíbia/cirurgia
7.
Int J Comput Assist Radiol Surg ; 14(5): 755-762, 2019 May.
Artigo em Inglês | MEDLINE | ID: mdl-30859457

RESUMO

PURPOSE: Manual segmentation is sensitive to operator bias, while semiautomatic random walks segmentation offers an intuitive approach to understand the user knowledge at the expense of large amount of user input. In this paper, we propose a novel random walks seed auto-generation (SAGE) hybrid model that is robust to interobserver error and intensive user intervention. METHODS: Knee image is first oversegmented to produce homogeneous superpixels. Then, a ranking model is developed to rank the superpixels according to their affinities to standard priors, wherein background superpixels would have lower ranking values. Finally, seed labels are generated on the background superpixel using Fuzzy C-Means method. RESULTS: SAGE has achieved better interobserver DSCs of 0.94 ± 0.029 and 0.93 ± 0.035 in healthy and OA knee segmentation, respectively. Good segmentation performance has been reported in femoral (Healthy: 0.94 ± 0.036 and OA: 0.93 ± 0.034), tibial (Healthy: 0.91 ± 0.079 and OA: 0.88 ± 0.095) and patellar (Healthy: 0.88 ± 0.10 and OA: 0.84 ± 0.094) cartilage segmentation. Besides, SAGE has demonstrated greater mean readers' time of 80 ± 19 s and 80 ± 27 s in healthy and OA knee segmentation, respectively. CONCLUSIONS: SAGE enhances the efficiency of segmentation process and attains satisfactory segmentation performance compared to manual and random walks segmentation. Future works should validate SAGE on progressive image data cohort using OA biomarkers.


Assuntos
Algoritmos , Cartilagem Articular/diagnóstico por imagem , Articulação do Joelho/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos , Osteoartrite do Joelho/diagnóstico , Fêmur/diagnóstico por imagem , Humanos , Reprodutibilidade dos Testes , Tíbia/diagnóstico por imagem
8.
Biochem Mol Biol Educ ; 46(3): 245-252, 2018 05.
Artigo em Inglês | MEDLINE | ID: mdl-29488323

RESUMO

The appreciation and understanding of gas generation through processes is vital in biochemical education. In this work, an augmented reality tool is reported to depict the redox reaction between hydrogen peroxide and sodium hypochlorite solutions, two ubiquitous oxidizing agents, to create oxygen, a combustible gas. As it operates out of smartphones or tablets, students are able to conduct the exercise collaboratively, respond in a manner similar to an actual physical experiment, and able to depict the oxygen volume changes in relation to the volume of hydrogen peroxide of different concentrations used. The tool offers to help students acquire bench skills by limiting handing risks and to mitigate possible student anxiety on handling chemical materials and implements in the laboratory. The feedback received from Year 11 and 12 high school student participants in an outreach exercise indicate the overall effectiveness of this tool. © 2018 by The International Union of Biochemistry and Molecular Biology, 46(3):245-252, 2018.


Assuntos
Peróxido de Hidrogênio/química , Oxigênio/química , Aprendizagem Baseada em Problemas , Hipoclorito de Sódio/química , Estudantes , Compreensão , Humanos , Instituições Acadêmicas
9.
Biomed Mater Eng ; 24(6): 3145-57, 2014.
Artigo em Inglês | MEDLINE | ID: mdl-25227024

RESUMO

In medical image segmentation, manual segmentation is considered both labor- and time-intensive while automated segmentation often fails to segment anatomically intricate structure accordingly. Interactive segmentation can tackle shortcomings reported by previous segmentation approaches through user intervention. To better reflect user intention, development of suitable editing functions is critical. In this paper, we propose an interactive knee cartilage extraction software that covers three important features: intuitiveness, speed, and convenience. The segmentation is performed using multi-label random walks algorithm. Our segmentation software is simple to use, intuitive to normal and osteoarthritic image segmentation and efficient using only two third of manual segmentation's time. Future works will extend this software to three dimensional segmentation and quantitative analysis.


Assuntos
Algoritmos , Cartilagem Articular/patologia , Aumento da Imagem/métodos , Interpretação de Imagem Assistida por Computador/métodos , Osteoartrite do Joelho/patologia , Reconhecimento Automatizado de Padrão/métodos , Interface Usuário-Computador , Inteligência Artificial , Humanos , Variações Dependentes do Observador , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA