Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 32
Filtrar
1.
Biofabrication ; 16(3)2024 Apr 12.
Artigo em Inglês | MEDLINE | ID: mdl-38569492

RESUMO

Tissue engineering has emerged as an advanced strategy to regenerate various tissues using different raw materials, and thus it is desired to develop more approaches to fabricate tissue engineering scaffolds to fit specific yet very useful raw materials such as biodegradable aliphatic polyester like poly (lactide-co-glycolide) (PLGA). Herein, a technique of 'wet 3D printing' was developed based on a pneumatic extrusion three-dimensional (3D) printer after we introduced a solidification bath into a 3D printing system to fabricate porous scaffolds. The room-temperature deposition modeling of polymeric solutions enabled by our wet 3D printing method is particularly meaningful for aliphatic polyester, which otherwise degrades at high temperature in classic fuse deposition modeling. As demonstration, we fabricated a bilayered porous scaffold consisted of PLGA and its mixture with hydroxyapatite for regeneration of articular cartilage and subchondral bone. Long-termin vitroandin vivodegradation tests of the scaffolds were carried out up to 36 weeks, which support the three-stage degradation process of the polyester porous scaffold and suggest faster degradationin vivothanin vitro. Animal experiments in a rabbit model of articular cartilage injury were conducted. The efficacy of the scaffolds in cartilage regeneration was verified through histological analysis, micro-computed tomography (CT) and biomechanical tests, and the influence of scaffold structures (bilayerversussingle layer) onin vivotissue regeneration was examined. This study has illustrated that the wet 3D printing is an alternative approach to biofabricate tissue engineering porous scaffolds based on biodegradable polymers.


Assuntos
Cartilagem Articular , Animais , Coelhos , Porosidade , Microtomografia por Raio-X , Temperatura , Alicerces Teciduais/química , Engenharia Tecidual/métodos , Polímeros , Poliésteres , Impressão Tridimensional
2.
Rev Sci Instrum ; 95(5)2024 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-38804810

RESUMO

Pulsed power generators utilizing magnetic switch technology within the 100 ns scale have become widespread for surface treatment, high power microwave generation, and food processing, in which the dynamic characteristics of the magnetic switch perform an important function. The saturation process, electric field between layers, and energy loss are closely associated with the applied time scale of the magnetic core, which affects the dynamic characteristics of the switch. However, compared with the study within the microsecond scale, the dynamic characteristics of magnetic switches within the 100 ns scale have not been studied in depth. In this paper, the dynamic characteristics of a coaxial magnetic switch modulating pulse forming networks (PFNs) are studied via both field-loop co-simulation and scaled experimental test. It is found that increasing PFN section number (Ns) leads to an acceleration in the saturation process of the core, which helps understand the switch performance of the magnetic core more clearly. With respect to a specific magnetic switch based on a ferromagnetic core, it is quantitatively analyzed that increasing Ns from 1 to 10 leads to a 16.1% reduction in core saturation time (tsat), a 13.4% increase in eddy loss (EET), and a 5.7% rise in maximum interlamination field strength (Emax) under the 100 ns scale; however, tsat is reduced by 19.3%, EET increases by 5.2%, and Emax rises by 2.3% under the microsecond scale. The results could provide a design reference for magnetic switches in pulsed power generators.

3.
Rev Sci Instrum ; 95(5)2024 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-38780390

RESUMO

A pulse forming network (PFN) is a significant component, contributing a lot to the overall dimension of pulse generators. In order to both reduce the size of PFN and improve the output waveform quality, this paper proposes a compact low-impedance PFN with a rotational symmetry structure. The PFN consists of four groups of Blumlein pulse forming units (PFUs) connected in parallel along the angular direction, and the spline curve structure is applied in each PFU, which achieves a higher space utilization rate. The theoretical maximum energy density of PFN is 6.6 J/L as the dimensions of PFN are φ500 × 138 mm. Field-circuit co-simulation is carried out based on the spatial model of PFN and the double switch modulation circuit to analyze the effects of switch delay time (time between main switch and steep discharge switch), as well as the output port position affecting the output pulse waveform. The results show that the PFN is appropriate to achieve quasi-square wave pulse modulation as the switch delay time is 290 ns with the output port positioned at the periphery. The verification experiments are also carried out. The results show that the PFN can generate a quasi-square wave pulse with an output voltage of 49.6 kV, a pulse width of 83 ns, and a peak power of 1 GW on a matched load. The output pulse exhibits a distinct flat top, with the fluctuation of the plateau being less than 3%.

4.
Rev Sci Instrum ; 95(8)2024 Aug 01.
Artigo em Inglês | MEDLINE | ID: mdl-39120447

RESUMO

Pulse forming lines (PFL) are widely applied in high-power pulsed power generators due to their high energy density and great ability with square waveform modulation. However, the three-cylinder coaxial Blumlein line (tPFL), a commonly used PFL structure, has low energy efficiency due to the difference in impedance of the outer and inner lines. In order to increase the outer line impedance and improve the output waveform of the PFL, a racetrack Blumlein pulse forming line (r-B PFL), formed by two inner cylinders, two middle cylinders, and one outer cylinder that resembles a runway shape, is proposed in this paper. The glycerin energy storage technology and the spiral line technology were applied in the PFL. Moreover, the r-B PFL was tested experimentally after its construction, yielding a satisfactory result. The PFL structure in which multiple middle cylinders share the same outer cylinder achieves a higher outer line impedance, leading to a high energy efficiency of the PFL, which contributes to the PFL development trend toward compactness and miniaturization.

5.
ACS Appl Mater Interfaces ; 15(4): 6142-6155, 2023 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-36637977

RESUMO

Surface topography is a biophysical factor affecting cell behaviors, yet the underlying cues are still not clear. Herein, we hypothesized that stereo coverage and overall stiffness of biomaterial arrays on the scale of single cells underly parts of topography effects on cell adhesion. We fabricated a series of microarrays (micropillar, micropit, and microtube) of poly(l-lactic acid) (PLLA) using mold casting based on pre-designed templates. The characteristic sizes of array units were less than that of a single cell, and thus, each cell could sense the micropatterns with varied roughness. With human umbilical vein endothelial cells (HUVECs) as the model cell type, we examined spreading areas and cell viabilities on different surfaces. "Stereo coverage" was defined to quantify the actual cell spreading fraction on a topographic surface. Particularly in the case of high micropillars, cells were confirmed not able to touch the bottom and had to partially hang among the micropillars. Then, in our opinion, a cell sensed the overall stiffness combining the bulk stiffness of the raw material and the stiffness of the culture medium. Spreading area and single cell viability were correlated to coverage and topographic feature of the prepared microarrays in particular with the significantly protruded geometry feather. Cell traction forces exerted on micropillars were also discussed. These findings provide new insights into the surface modifications toward biomedical implants.


Assuntos
Materiais Biocompatíveis , Humanos , Adesão Celular , Células Endoteliais da Veia Umbilical Humana , Propriedades de Superfície
6.
Rev Sci Instrum ; 94(1): 014707, 2023 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-36725560

RESUMO

The high power pulse generators have been widely used in high power microwave generation and plasma physics research. In this paper, a novel compact solid-state high power pulse generator is studied, numerically and experimentally. The generator is mainly composed of the primary energy supply, the magnetic pulse compressor, the Blumlein type low-impedance pulse forming network, and the square waveform pulse transformer. Especially, design considerations for a solid-state high power pulse generator are proposed. Experimental results show that pulses with a peak power of 2 GW, a duration of 150 ns, and a repetitive rate of 10 Hz are continuously achieved on a dummy load. The dimension is Φ60 × 210 cm2, and the average power density reaches ∼5 W/L. Experimental results show reasonable agreement with numerical analysis.

7.
Regen Biomater ; 10: rbad035, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37206162

RESUMO

Magnetic resonance imaging (MRI) is a promising non-invasive method to assess cartilage regeneration based on the quantitative relationship between MRI features and concentrations of the major components in the extracellular matrix (ECM). To this end, in vitro experiments are performed to investigate the relationship and reveal the underlying mechanism. A series of collagen (COL) and glycosaminoglycan (GAG) solutions at different concentrations are prepared, and T1 and T2 relaxation times are measured with or without a contrast agent (Gd-DTPA2-) by MRI. Fourier transform infrared spectrometry is also used to measure the contents of biomacromolecule-bound water and other water, allowing theoretical derivation of the relationship between biomacromolecules and the resulting T2 values. It has been revealed that the MRI signal in the biomacromolecule aqueous systems is mainly influenced by the protons in hydrogens of biomacromolecule-bound water, which we divide into inner-bound water and outer-bound water. We have also found that COL results in higher sensitivity of bound water than GAG in T2 mapping. Owing to the charge effect, GAG regulates the penetration of the contrast agent during dialysis and has a more significant effect on T1 values than COL. Considering that COL and GAG are the most abundant biomacromolecules in the cartilage, this study is particularly useful for the real-time MRI-guided assessment of cartilage regeneration. A clinical case is reported as an in vivo demonstration, which is consistent with our in vitro results. The established quantitative relation plays a critical academic role in establishing an international standard ISO/TS24560-1:2022 'Clinical evaluation of regenerative knee articular cartilage using delayed gadolinium-enhanced MRI of cartilage (dGEMRIC) and T2 mapping' drafted by us and approved by International Standard Organization.

8.
Nat Nanotechnol ; 18(9): 1085-1093, 2023 09.
Artigo em Inglês | MEDLINE | ID: mdl-37142709

RESUMO

High rates of ligament damage require replacements; however, current synthetic materials have issues with bone integration leading to implant failure. Here we introduce an artificial ligament that has the required mechanical properties and can integrate with the host bone and restore movement in animals. The ligament is assembled from aligned carbon nanotubes formed into hierarchical helical fibres bearing nanometre and micrometre channels. Osseointegration of the artificial ligament is observed in an anterior cruciate ligament replacement model where clinical polymer controls showed bone resorption. A higher pull-out force is found after a 13-week implantation in rabbit and ovine models, and animals can run and jump normally. The long-term safety of the artificial ligament is demonstrated, and the pathways involved in integration are studied.


Assuntos
Ligamento Cruzado Anterior , Nanotubos de Carbono , Ovinos , Animais , Coelhos , Ligamento Cruzado Anterior/cirurgia , Fibra de Carbono , Próteses e Implantes
9.
Rev Sci Instrum ; 93(5): 054704, 2022 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-35649789

RESUMO

In recent years, the pulse forming technology based on metal oxide varistors (MOVs) has been verified to be an effective way to generate high-voltage quasi-square pulses. Due to the limited varistor voltage of a single MOV brick, multiple MOV bricks connected in series are required to stabilize a pulse with high amplitude (larger than hundreds of kV), which leads to the rise of the series inductance of the MOV branch and the flat-top droop in the output waveform. This paper provides two solutions to reduce the influence of the MOV branch inductance on output waveforms. One is that a coaxial evolute structure of the MOV bricks connected in series is designed, which can not only improve the insulation capacity but also reduce the branch inductance. Another is that a flat-top compensation scheme named "PFN-MOV" (Pulse Forming Network) is proposed, which adds an LC filtering branch to shape the signal into a flat-top rising wave with ripple and then offsets the flat-top droop caused by the inductance of the MOV branch. Based on the above ideas, a high-voltage, long-pulse width, flat-top compensation pulse generator is designed and tested, and a quasi-square pulse with voltage amplitude of more than 500 kV, pulse width greater than 800 ns, rise time of less than 50 ns, and flat top of about 600 ns is obtained experimentally. This MOV based generator has the advantage of simple design, compact construction, and better flat top, which is promising to be used as a compact long-pulse driver in many fields, such as high-current accelerator, industrial dedusting, medical sterilization, and cancer treatment.

10.
ACS Appl Mater Interfaces ; 14(14): 15982-15995, 2022 Apr 13.
Artigo em Inglês | MEDLINE | ID: mdl-35363484

RESUMO

The treatment of cartilage injury and osteoarthritis has been a classic problem for many years. The idea of in situ tissue regeneration paves a way for osteochondral repair in vivo. Herein, a hydrogel scaffold linked with bioactive peptides that can selectively adsorb transforming growth factor ß1 (TGF-ß1) was hypothesized to not only afford cell ingrowth space but also induce the endogenous TGF-ß1 recruitment for chondrogenesis promotion. In this study, bilayered porous scaffolds with gelatin methacryloyl (GelMA) hydrogels as a matrix were constructed via three-dimensional (3D) printing, of which the upper layer was covalently bound with bioactive peptides that can adsorb TGF-ß1 for cartilage repair and the lower layer was blended with hydroxyapatite for subchondral regeneration. The scaffolds showed promising therapeutic efficacy proved by cartilage and osteogenic induction in vitro and osteochondral repair of rats in vivo. In particular, the animal gait behavior was recovered after the in situ tissue regeneration, and the corresponding gait analysis demonstrated the promotion of tissue regeneration induced by the porous hydrogels with the binding peptides.


Assuntos
Hidrogéis , Fator de Crescimento Transformador beta1 , Animais , Cartilagem , Condrogênese , Marcha , Gelatina , Hidrogéis/metabolismo , Hidrogéis/farmacologia , Metacrilatos , Peptídeos/metabolismo , Peptídeos/farmacologia , Porosidade , Impressão Tridimensional , Ratos , Engenharia Tecidual , Alicerces Teciduais , Fator de Crescimento Transformador beta1/farmacologia
11.
ACS Appl Mater Interfaces ; 14(33): 37436-37446, 2022 Aug 24.
Artigo em Inglês | MEDLINE | ID: mdl-35943249

RESUMO

Directed migration of cells through cell-surface interactions is a paramount prerequisite in biomaterial-induced tissue regeneration. However, whether and how the nanoscale spatial gradient of adhesion molecules on a material surface can induce directed migration of cells is not sufficiently known. Herein, we employed block copolymer micelle nanolithography to prepare gold nanoarrays with a nanospacing gradient, which were prepared by continuously changing the dipping velocity. Then, a self-assembly monolayer technique was applied to graft arginine-glycine-aspartate (RGD) peptides on the nanodots and poly(ethylene glycol) (PEG) on the glass background. Since RGD can trigger specific cell adhesion via conjugating with integrin (its receptor in the cell membrane) and PEG can resist protein adsorption and nonspecific cell adhesion, a nanopattern with cell-adhesion contrast and a gradient of RGD nanospacing was eventually prepared. In vitro cell behaviors were examined using endothelial cells (ECs) and smooth muscle cells (SMCs) as a demonstration. We found that SMCs exhibited significant orientation and directed migration along the nanospacing gradient, while ECs exhibited only a weak spontaneously anisotropic migration. The gradient response was also dependent upon the RGD nanospacing ranges, namely, the start and end nanospacings under a given distance and gradient. The different responses of these two cell types to the RGD nanospacing gradient provide new insights for designing cell-selective nanomaterials potentially used in cell screening, wound healing, etc.


Assuntos
Células Endoteliais , Oligopeptídeos , Adesão Celular , Miócitos de Músculo Liso , Oligopeptídeos/química , Polietilenoglicóis/química
12.
Acta Biomater ; 145: 106-121, 2022 06.
Artigo em Inglês | MEDLINE | ID: mdl-35436591

RESUMO

Uncontrolled bleeding from internal noncompressible wounds is a major cause of prehospital death in military personnel and civilian populations. An ideal hemostatic sealant for emergency care should quickly control blood loss and be removed without debridement for the follow-up treatment in the operating room, yet the lack of suitable materials to meet both requirements is the bottleneck. Herein, we suggest an injectable and dissolvable hydrogel sealant for hemorrhage management of noncompressible wounds. To this end, a 4-arm poly(ethylene glycol) (PEG) crosslinker modified with thioester linkages and terminated with aldehyde groups is designed and synthesized, and to modulate the gel properties and make it suitable as a hemostatic sealant, a mixed amino component composed of poly(ethylene imine) and adipic dihydrazide is employed to react with the PEG crosslinker to form the adhesive and elastic sealant for the first time. The aldehyde groups provide the adhesion to the tissues, and the amino component affords the procoagulant ability. More importantly, the thioester moieties allow the on-demand dissolution of sealant via a thiol-thioester exchange reaction upon exposure to an exogenous thiolate solution. In the rat femoral artery puncture and liver injury models, the administration of the hydrogel sealant dramatically reduces blood loss, and its subsequent removal does not induce rebleeding. Consequently, this hydrogel sealant with the unique feature of on-demand dissolution can not only efficiently control bleeding in emergent scenarios, but also allow non-traumatic re-exposure of wounds during subsequent surgical care. STATEMENT OF SIGNIFICANCE: Sealants, adhesives or hemostatic dressings currently used in emergency situations not only require manual pressure to control bleeding, but also face removal by cutting and mechanical debridement to enable eventual surgical treatment. In this study, we design and develop an injectable and adhesive hydrogel sealant with good procoagulant capacity and on-demand dissolution feature. The application of the hydrogel sealant substantially reduces bleeding from internal noncompressible wounds without the need for direct pressure, and demonstrates for the first time that its controlled removal without debridement does not cause rebleeding. Considering that there are currently no commercial wound sealant systems with the feature of on-demand dissolution, the hydrogel sealant developed by us is expected to address an unmet clinical need.


Assuntos
Serviços Médicos de Emergência , Hemostáticos , Aldeídos , Animais , Materiais Biocompatíveis/farmacologia , Hemorragia/tratamento farmacológico , Hemostáticos/farmacologia , Hidrogéis/farmacologia , Ratos , Solubilidade
13.
ACS Appl Mater Interfaces ; 14(21): 24197-24212, 2022 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-35580332

RESUMO

Enabling a biodegradable polymer radiopaque under X-ray is much desired for many medical devices. Physical blending of a present biodegradable polymer and a commercialized medical contrast agent is convenient yet lacks comprehensive fundamental research. Herein, we prepared a biodegradable polymer-based radiopaque raw material by blending poly(l-lactic acid) (PLLA or simply PLA) and iohexol (IHX), where PLA constituted the continuous phase and IHX particles served as the dispersed phase. The strong X-ray adsorption of IHX enabled the composite radiopaque; the hydrolysis of the polyester and the water solubility of the contrast agent enabled the composite biodegradable in an aqueous medium. The idea was confirmed by in vitro characterizations of the resultant composite, in vivo subcutaneous implantation in rats up to 6 months, and the clear visualization of a part of a biodegradable occluder in a Bama piglet under X-ray. We also found that the crystallization of PLA was significantly enhanced in the presence of the solid particles, which should be taken into consideration in the design of an appropriate biomaterial composite because crystallization degree influences the biodegradation rate and mechanical property of a material to a large extent. We further tried to introduce a small amount of poly(vinylpyrrolidone) into the blend of PLA and IHX. Compared to the bicomponent composite, the tricomponent one exhibited decreased modulus and increased elongation at break and tensile strength. This paves more ways for researchers to select appropriate raw materials according to the regenerated tissue and the application site.


Assuntos
Meios de Contraste , Poliésteres , Animais , Materiais Biocompatíveis/química , Cristalização , Poliésteres/química , Polímeros/química , Ratos , Suínos
14.
Regen Biomater ; 9(1): rbac007, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35414958

RESUMO

The malalignment of teeth is treated classically by metal braces with alloy wires, which has an unfavorable influence on the patients appearance during the treatment. With the development of digitization, computer simulation and three-dimensional (3D) printing technology, herein, a modern treatment was tried using clear polymeric aligners, which were fabricated by molding polyurethane films via thermoforming on the 3D-printed personalized dental models. The key parameters of photocurable 3D printing of dental models and the mechanical properties of the clear aligner film material were examined. The precision of a 3D-printed dental model mainly relied on characteristics of photocurable resin, the resolution of light source and the exposure condition, which determined the eventual shape of the molded clear aligner and thus the orthodontic treatment efficacy. The biocompatibility of the polyurethane film material was confirmed through cytotoxicity and hemolysis tests in vitro. Following a series of 3D-printed personalized dental models and finite element analysis to predict and plan the fabrication and orthodontic processes, corresponding clear aligners were fabricated and applied in animal experiments, which proved the efficacy and biocompatibility in vivo. Clinical treatments of 120 orthodontic cases were finally carried out with success, which highlights the advantage of the clear aligners as an esthetic, compatible and efficient appliance.

15.
Rev Sci Instrum ; 92(2): 024708, 2021 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-33648145

RESUMO

A pulse forming network (PFN) has the advantages of compactness and long pulse achievability, which could meet the requirements of military and industrial applications of pulsed power technology well. In this paper, a compact low impedance Blumlein-type PFN based on ceramic capacitors is investigated numerically and experimentally. Generally, in order to increase the compactness of the PFN, an angular distribution and an axially parallel connected structure with a theoretical peak energy density of up to 5.8 J/L are employed. The dimensions of the PFN are Φ 560 × 345 mm2. A sharpening switch, which can efficiently reduce rise-time of the output pulses, is utilized to improve the performance of the PFN. The compact low impedance Blumlein-type PFN was assembled in our laboratory. The results of low voltage experiments show that the PFN could generate quasi-square pulses with an output power of 50 MW and a peak voltage of approximately 13.2 kV on a matched dummy load. Impedance and output pulse duration of the PFN are 3 Ω and 135 ns, respectively. The results of high voltage experiments show that pulses with a power of about 1 GW and an energy density of about 2.5 J/L were obtained. Experiments show reasonable agreement with numerical analysis.

16.
ACS Appl Mater Interfaces ; 13(36): 42344-42356, 2021 Sep 15.
Artigo em Inglês | MEDLINE | ID: mdl-34469116

RESUMO

Although many tissue regeneration processes after biomaterial implantation are related to migrations of multiple cell types on material surfaces, available tools to adjust relative migration speeds are very limited. Herein, we put forward a nanomaterial strategy to employ surface modification with arginine-glycine-aspartate (RGD) nanoarrays to tune in vitro cell migration using endothelial cells (ECs) and smooth muscle cells (SMCs) as demonstrated cell types. We found that migrations of both cell types exhibited a nonmonotonic trend with the increase of RGD nanospacing, yet with different peaks-74 nm for SMCs but 95 nm for ECs. The varied sensitivities afford a facile way to regulate the relative migration speeds. Although ECs migrated at a speed similar to SMCs on a non-nano surface, the migration of ECs could be controlled to be significantly faster or slower than SMCs simply by adjusting the RGD nanospacing. This study suggests a potential application of surface modification of biomaterials on a nanoscale level.


Assuntos
Materiais Biocompatíveis/química , Movimento Celular/fisiologia , Células Endoteliais/metabolismo , Miócitos de Músculo Liso/metabolismo , Oligopeptídeos/química , Adesão Celular/efeitos dos fármacos , Movimento Celular/efeitos dos fármacos , Ouro/química , Células Endoteliais da Veia Umbilical Humana , Humanos , Nanoestruturas/química , Poliestirenos/química , Polivinil/química , Piridinas/química
17.
Adv Healthc Mater ; 10(3): e2001404, 2021 02.
Artigo em Inglês | MEDLINE | ID: mdl-33225617

RESUMO

Cartilage is difficult to self-repair and it is more challenging to repair an osteochondral defects concerning both cartilage and subchondral bone. Herein, it is hypothesized that a bilayered porous scaffold composed of a biomimetic gelatin hydrogel may, despite no external seeding cells, induce osteochondral regeneration in vivo after being implanted into mammal joints. This idea is confirmed based on the successful continuous 3D-printing of the bilayered scaffolds combined with the sol-gel transition of the aqueous solution of a gelatin derivative (physical gelation) and photocrosslinking of the gelatin methacryloyl (gelMA) macromonomers (chemical gelation). At the direct printing step, a nascent physical hydrogel is extruded, taking advantage of non-Newtonian and thermoresponsive rheological properties of this 3D-printing ink. In particular, a series of crosslinked gelMA (GelMA) and GelMA-hydroxyapatite bilayered hydrogel scaffolds are fabricated to evaluate the influence of the spacing of 3D-printed filaments on osteochondral regeneration in a rabbit model. The moderately spaced scaffolds output excellent regeneration of cartilage with cartilaginous lacunae and formation of subchondral bone. Thus, tricky rheological behaviors of soft matter can be employed to improve 3D-printing, and the bilayered hybrid scaffold resulting from the continuous 3D-printing is promising as a biomaterial to regenerate articular cartilage.


Assuntos
Hidrogéis , Alicerces Teciduais , Animais , Tinta , Porosidade , Impressão Tridimensional , Coelhos
18.
Regen Biomater ; 8(5): rbab038, 2021 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-34408910

RESUMO

With the development of tissue engineering and regenerative medicine, it is much desired to establish bioimaging techniques to monitor the real-time regeneration efficacy in vivo in a non-invasive way. Herein, we tried magnetic resonance imaging (MRI) to evaluate knee cartilage regeneration after implanting a biomaterial scaffold seeded with chondrocytes, namely, matrix-induced autologous chondrocyte implantation (MACI). After summary of the T2 mapping and the T1-related delayed gadolinium-enhanced MRI imaging of cartilage (dGEMRIC) in vitro and in vivo in the literature, these two MRI techniques were tried clinically. In this study, 18 patients were followed up for 1 year. It was found that there was a significant difference between the regeneration site and the neighboring normal site (control), and the difference gradually diminished with regeneration time up to 1 year according to both the quantitative T1 and T2 MRI methods. We further established the correlation between the quantitative evaluation of MRI and the clinical Lysholm scores for the first time. Hence, the MRI technique was confirmed to be a feasible semi-quantitative yet non-invasive way to evaluate the in vivo regeneration of knee articular cartilage.

19.
Rev Sci Instrum ; 90(1): 014704, 2019 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-30709186

RESUMO

In this paper, a compact solid-state high voltage pulse generator, composed of a pulse transformer and a magnetic pulse compressor, is investigated numerically and experimentally. The generator can achieve pulses with a peak voltage over several tens of kilovolts and a rise-time in the microsecond level, which can be widely used in plasma physics research, high power microwave generation, and material treatment. Specifically, PSpice software is used to analyze the performance of the generator. Then, the generator was constructed in our laboratory. The experimental results illustrate that when the charging voltage of the generator was changing from 10 kV to 14 kV, typical pulses with a peak voltage ranging from 67 kV to 95 kV and rise-time between 10 µs and 12 µs were obtained on a dummy load. The generator can continually work over 10 min with a repetitive rate of 20 Hz, and until now, it has been successfully achieving over 1 × 106 high voltage pulses. Experiments show reasonable agreement with numerical analysis.

20.
Rev Sci Instrum ; 90(4): 044701, 2019 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-31043006

RESUMO

Ferromagnetic core based magnetic switches are widely used in various pulsed power facilities. The dynamic characteristics of high-power magnetic switches, which have important impacts on the pulse modulation process, are analyzed via an improved numerical model in this paper. The model is established by simultaneously solving the circuit equations and the magnetic field diffusion equations. An implicit finite difference method is used in solving the diffusion equations, which has no numerical convergence problems, and the Jiles-Atherton model is used to obtain an accurate hysteresis loop of the core. The improved model predicts the performance of the magnetic switch quite well. It is then used to analyze the detailed dynamic saturation process of a core, and the core's saturation time predicted by the model is consistent with the experimental data, the error being less than 5%. Furthermore, the interlamination electric field is calculated and analyzed, and it is predicted that breakdown is most likely to occur at the inner side of the core and at the edge of the lamination.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA