Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
1.
Catheter Cardiovasc Interv ; 91(3): 402-407, 2018 02 15.
Artigo em Inglês | MEDLINE | ID: mdl-28500743

RESUMO

OBJECTIVES: This study is the first head-to-head analysis of StarClose vs. ProGlide in patients undergoing 5F or 6F percutaneous coronary catheterization or peripheral artery interventions. BACKGROUND: The clip based StarClose and the suture mediated ProGlide vascular closure device are well established for femoral hemostasis in endovascular therapy. However, until now no prospective randomized study compared the safety and efficacy of the two devices. METHODS: This prospective, randomized, single-center study enrolled 505 patients (69.6 ± 11.2 years) resulting in 538 procedures due to more than one intervention in several patients: We analyzed 422 cardiac catheterization and 116 peripheral artery interventions via a common femoral artery access. Patients were randomized to StarClose or ProGlide (1:1). In-hospital complications (major bleeding, hematoma, pseudoaneurysm, vessel occlusion, and arteriovenous fistula) and device failure were recorded. The puncture site was assessed by ultrasound in all patients prior to discharge. RESULTS: Overall complication rate was 3.9%. There were more complications after utilization of StarClose compared to ProGlide (5.6 vs. 2.2%, P = 0.064), which was significant in adjusted logistic regression analysis with a 2.9-fold increased risk of complications for StarClose (P < 0.05). In the subgroup of coronary catheterizations there were significantly more complications for StarClose compared to ProGlide (1.4 vs. 5.2%, P < 0.05) with a 4.7-fold increased risk. Device failure rate was not significantly different between the two devices. CONCLUSION: In this first randomized trial comparing the two closure systems complication rate was higher for StarClose with equal efficacy compared to ProGlide. © 2017 Wiley Periodicals, Inc.


Assuntos
Cateterismo Cardíaco/métodos , Cateterismo Periférico/métodos , Artéria Femoral , Hemorragia/prevenção & controle , Técnicas Hemostáticas/instrumentação , Técnicas de Sutura/instrumentação , Dispositivos de Oclusão Vascular , Idoso , Idoso de 80 Anos ou mais , Cateterismo Cardíaco/efeitos adversos , Cateterismo Periférico/efeitos adversos , Feminino , Artéria Femoral/diagnóstico por imagem , Alemanha , Hemorragia/etiologia , Técnicas Hemostáticas/efeitos adversos , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Punções , Fatores de Risco , Técnicas de Sutura/efeitos adversos , Resultado do Tratamento
2.
J Cardiovasc Magn Reson ; 17: 112, 2015 Dec 22.
Artigo em Inglês | MEDLINE | ID: mdl-26695427

RESUMO

BACKGROUND: Cardiovascular Magnetic Resonance (CMR) with adenosine stress is a valuable diagnostic tool in coronary artery disease (CAD). However, despite the development of MR conditional pacemakers CMR is not yet established in clinical routine for pacemaker patients with known or suspected CAD. A possible reason is that adenosine stress perfusion for ischemia detection in CMR has not been studied in patients with cardiac conduction disease requiring pacemaker therapy. Other than under resting conditions it is unclear whether MR safe pacing modes (paused pacing or asynchronous mode) can be applied safely because the effect of adenosine on heart rate is not precisely known in this entity of patients. We investigate for the first time feasibility and safety of adenosine stress CMR in pacemaker patients in clinical routine and evaluate a pacing protocol that considers heart rate changes under adenosine. METHODS: We retrospectively analyzed CMR scans of 24 consecutive patients with MR conditional pacemakers (mean age 72.1 ± 11.0 years) who underwent CMR in clinical routine for the evaluation of known or suspected CAD. MR protocol included cine imaging, adenosine stress perfusion and late gadolinium enhancement. RESULTS: Pacemaker indications were sinus node dysfunction (n = 18) and second or third degree AV block (n = 6). Under a pacing protocol intended to avoid competitive pacing on the one hand and bradycardia due to AV block on the other no arrhythmia occurred. Pacemaker stimulation was paused to prevent competitive pacing in sinus node dysfunction with resting heart rate >45 bpm. Sympatho-excitatory effect of adenosine led to a significant acceleration of heart rate by 12.3 ± 8.3 bpm (p < 0.001), no bradycardia occurred. On the contrary in AV block heart rate remained constant; asynchronous pacing above resting heart rate did not interfere with intrinsic rhythm. CONCLUSION: Adenosine stress CMR appears to be feasible and safe in patients with MR conditional pacemakers. Heart rate response to adenosine has to be considered for the choice of pacing modes during CMR.


Assuntos
Adenosina/administração & dosagem , Arritmias Cardíacas/terapia , Estimulação Cardíaca Artificial , Doença da Artéria Coronariana/diagnóstico , Circulação Coronária , Vasos Coronários/fisiopatologia , Imagem Cinética por Ressonância Magnética/métodos , Imagem de Perfusão do Miocárdio/métodos , Marca-Passo Artificial , Vasodilatadores/administração & dosagem , Adenosina/efeitos adversos , Idoso , Idoso de 80 Anos ou mais , Arritmias Cardíacas/diagnóstico , Arritmias Cardíacas/fisiopatologia , Velocidade do Fluxo Sanguíneo , Estimulação Cardíaca Artificial/efeitos adversos , Estimulação Cardíaca Artificial/métodos , Meios de Contraste , Doença da Artéria Coronariana/fisiopatologia , Desenho de Equipamento , Estudos de Viabilidade , Feminino , Frequência Cardíaca/efeitos dos fármacos , Humanos , Imagem Cinética por Ressonância Magnética/efeitos adversos , Masculino , Pessoa de Meia-Idade , Marca-Passo Artificial/efeitos adversos , Segurança do Paciente , Valor Preditivo dos Testes , Fluxo Sanguíneo Regional , Estudos Retrospectivos , Fatores de Risco , Vasodilatadores/efeitos adversos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA