RESUMO
OBJECTIVE: We correlate and evaluate the accuracy of accepted anthropometric methods of percent body fat (%BF) quantification, namely, hydrostatic weighing (HW) and air displacement plethysmography (ADP), to 2 automatic adipose tissue quantification methods using computed tomography (CT). METHODS: Twenty volunteer subjects (14 men, 6 women) received head-to-toe CT scans. Hydrostatic weighing and ADP were obtained from 17 and 12 subjects, respectively. The CT data underwent conversion using 2 separate algorithms, namely, the Schneider method and the Beam method, to convert Hounsfield units to their respective tissue densities. The overall mass and %BF of both methods were compared with HW and ADP. RESULTS: When comparing ADP to CT data using the Schneider method and Beam method, correlations were r = 0.9806 and 0.9804, respectively. Paired t tests indicated there were no statistically significant biases. Additionally, observed average differences in %BF between ADP and the Schneider method and the Beam method were 0.38% and 0.77%, respectively. The %BF measured from ADP, the Schneider method, and the Beam method all had significantly higher mean differences when compared with HW (3.05%, 2.32%, and 1.94%, respectively). CONCLUSIONS: We have shown that total body mass correlates remarkably well with both the Schneider method and Beam method of mass quantification. Furthermore, %BF calculated with the Schneider method and Beam method CT algorithms correlates remarkably well with ADP. The application of these CT algorithms have utility in further research to accurately stratify risk factors with periorgan, visceral, and subcutaneous types of adipose tissue, and has the potential for significant clinical application.
Assuntos
Tecido Adiposo/diagnóstico por imagem , Peso Corporal/fisiologia , Tomografia Computadorizada por Raios X/métodos , Imagem Corporal Total/métodos , Adulto , Composição Corporal/fisiologia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Pletismografia/métodos , Reprodutibilidade dos TestesRESUMO
OBJECTIVE: The objective of this study was to determine the gadolinium (Gd) concentration remaining in human bone tissue after administration of standard clinical doses of 2 Gd-based contrast agents: ProHance and Omniscan. MATERIALS AND METHODS: After administration of 0.1 mmol/kg of Gd chelate to patients undergoing hip replacement surgery, bone specimens were collected and analyzed, and compared with an age-matched control population without a history of Gd chelate administration. Bone specimens were collected fresh, refrigerated, and subsequently frozen. After grinding and freeze-drying, tissue digestion was performed using Teflon bombs and concentrated nitric acid. A method for analysis of Gd in bone specimens was developed and validated using inductively coupled plasma mass spectroscopy (ICP-MS). RESULTS: Results were compared with a previous study using a different technique for analysis of the same tissue specimens. Tissue retention was 1.77+/-0.704 microg Gd/g bone (n=9) for Omniscan and 0.477+/-0.271 microg Gd/g bone (n=10) for ProHance measured by ICP-MS. These findings confirmed results from the previous ICP-AES study. CONCLUSION: Omniscan (Gd[DTPA-BMA]) left approximately 4 times (previous study 2.5 times) more Gd behind in bone than did ProHance (Gd[HP-DO3A]).
Assuntos
Meios de Contraste/farmacocinética , Cabeça do Fêmur/metabolismo , Gadolínio DTPA/farmacocinética , Compostos Heterocíclicos/farmacocinética , Espectrometria de Massas , Compostos Organometálicos/farmacocinética , Artroplastia de Quadril , Tecido Conjuntivo , Meios de Contraste/metabolismo , Gadolínio , Gadolínio DTPA/metabolismo , Compostos Heterocíclicos/metabolismo , Humanos , Compostos Organometálicos/metabolismo , Análise de RegressãoRESUMO
We have come full circle from spinning quarks to 3D medical images. The bulk of MRI is now performed using slice-selective gradients, during which RF energy is applied to excite the hydrogen nuclei. By stepping a phase-encoding gradient during each TR and using a frequency-encoding gradient as the data are sampled, the 3D human object can be reduced to many individual points or voxels. By acquiring multiple slices at once, the time efficiency of imaging can be vastly improved. Many newer strategies use variations of this technique to acquire multiple lines of data during a single echo, enshrining spin warp imaging as the most important method of signal acquisition for MRI.
Assuntos
Imageamento por Ressonância Magnética , Espectroscopia de Ressonância de Spin Eletrônica , Humanos , Processamento de Imagem Assistida por Computador , Magnetismo , Prótons , Teoria Quântica , Ondas de RádioRESUMO
BACKGROUND: Central adipose tissue is appreciated as a risk factor for cardiometabolic disorders. The purpose of this study was to determine the efficacy of a volumetric 3D analysis of central adipose tissue in predicting disease. Full body computerized tomography (CT) scans were obtained from 1225 female (518) and male (707) subjects, aged 18-88. Percent central body fat (%cBF) was determined by quantifying the adipose tissue volume from the dome of the liver to the pubic symphysis. Calcium score was determined from the calcium content of coronary arteries. Relationships between %cBF, BMI, and several cardiometabolic disorders were assessed controlling for age, sex, and race. RESULTS: Higher %cBF was significantly greater for those with type 2 diabetes and hypertension, but not stroke or hypercholesterolemia. Simple anthropometric determination of BMI equally correlated with diabetes and hypertension as central body fat. Calcium scoring significantly correlated with all measurements of cardiovascular health, including hypertension, hypercholesterolemia, and heart disease. CONCLUSIONS: Central body fat and BMI equally and highly predict incidence of hypertension and type 2 diabetes.
RESUMO
RATIONALE AND OBJECTIVES: Human bone tissue was collected following administration of a clinical dose of gadolinium chelate (0.1 mmol per kg) to patients undergoing hip joint replacement surgery to determine if measurable differences in Gd deposition occur between 2 widely available magnetic resonance contrast agents. MATERIALS AND METHODS: Gd HP-DO3A (ProHance), Gd DTPA-BMA (Omniscan), and an age-matched control population without history of gadolinium chelate administration were compared. Bone samples were collected fresh, placed in refrigeration, and subsequently frozen. Tissue digestion was performed using a microwave tissue digester and concentrated nitric acid. A method of tissue analysis was created for gadolinium using inductivity coupled plasma atomic emission spectroscopy (ICP-AES). RESULTS: Tissue retention was 1.18 +/- .787 microg Gd/g bone (N = 10) for Omniscan and 0.466 +/- .387 microg Gd/g bone (N = 8) for ProHance measured by ICP-AES. CONCLUSION: Omniscan (Gd DTPA-BMA) left 2.5 times more Gd behind in bone than did ProHance (Gd HP-DO3A).