Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 83
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
J Lipid Res ; 62: 100020, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-33581415

RESUMO

Carotid atherosclerosis is a risk factor for ischemic stroke, one of the main causes of mortality and disability worldwide. The disease is characterized by plaques, heterogeneous deposits of lipids, and necrotic debris in the vascular wall, which grow gradually and may remain asymptomatic for decades. However, at some point a plaque can evolve to a high-risk plaque phenotype, which may trigger a cerebrovascular event. Lipids play a key role in the development and progression of atherosclerosis, but the nature of their involvement is not fully understood. Using matrix-assisted laser desorption/ionization mass spectrometry imaging, we visualized the distribution of approximately 200 different lipid signals, originating of >90 uniquely assigned species, in 106 tissue sections of 12 human carotid atherosclerotic plaques. We performed unsupervised classification of the mass spectrometry dataset, as well as a histology-directed multivariate analysis. These data allowed us to extract the spatial lipid patterns associated with morphological plaque features in advanced plaques from a symptomatic population, revealing spatial lipid patterns in atherosclerosis and their relation to histological tissue type. The abundances of sphingomyelin and oxidized cholesteryl ester species were elevated specifically in necrotic intima areas, whereas diacylglycerols and triacylglycerols were spatially correlated to areas containing the coagulation protein fibrin. These results demonstrate a clear colocalization between plaque features and specific lipid classes, as well as individual lipid species in high-risk atherosclerotic plaques.


Assuntos
Doenças das Artérias Carótidas
2.
Stroke ; 52(8): 2510-2517, 2021 08.
Artigo em Inglês | MEDLINE | ID: mdl-34078112

RESUMO

Background and Purpose: Mechanical properties of thromboemboli play an important role in the efficacy of endovascular thrombectomy (EVT) for acute ischemic stroke. However, very limited data on mechanical properties of human stroke thrombi are available. We aimed to mechanically characterize thrombi retrieved with EVT, and to assess the relationship between thrombus composition and thrombus stiffness. Methods: Forty-one thrombi from 19 patients with acute stroke who underwent EVT between July and October 2019 were mechanically analyzed, directly after EVT. We performed unconfined compression experiments and determined tangent modulus at 75% strain (Et75) as a measure for thrombus stiffness. Thrombi were histologically analyzed for fibrin/platelets, erythrocytes, leukocytes, and platelets, and we assessed the relationship between histological components and Et75 with univariable and multivariable linear mixed regression. Results: Median Et75 was 560 (interquartile range, 393­1161) kPa. In the multivariable analysis, fibrin/platelets were associated with increased Et75 (aß, 9 [95% CI, 5 to 13]) kPa, erythrocytes were associated with decreased Et75% (aß, −9 [95% CI, −5 to −13]) kPa. We found no association between leukocytes and Et75. High platelet values were strongly associated with increased Et75 (aß, 56 [95% CI, 38­73]). Conclusions: Fibrin/platelet content of thrombi retrieved with EVT for acute ischemic stroke is strongly associated with increased thrombus stiffness. For thrombi with high platelet values, there was a very strong relationship with thrombus stiffness. Our data provide a basis for future research on the development of next-generation EVT devices tailored to thrombus composition.


Assuntos
Fenômenos Biomecânicos/fisiologia , Isquemia Encefálica/cirurgia , Procedimentos Endovasculares/métodos , AVC Isquêmico/cirurgia , Trombectomia/métodos , Trombose/cirurgia , Idoso , Idoso de 80 Anos ou mais , Isquemia Encefálica/patologia , Isquemia Encefálica/fisiopatologia , Procedimentos Endovasculares/instrumentação , Feminino , Humanos , AVC Isquêmico/patologia , AVC Isquêmico/fisiopatologia , Masculino , Pessoa de Meia-Idade , Trombectomia/instrumentação , Trombose/patologia , Trombose/fisiopatologia
3.
Eur Heart J ; 41(31): 2997-3004, 2020 08 14.
Artigo em Inglês | MEDLINE | ID: mdl-32402086

RESUMO

Despite advanced understanding of the biology of atherosclerosis, coronary heart disease remains the leading cause of death worldwide. Progress has been challenging as half of the individuals who suffer sudden cardiac death do not experience premonitory symptoms. Furthermore, it is well-recognized that also a plaque that does not cause a haemodynamically significant stenosis can trigger a sudden cardiac event, yet the majority of ruptured or eroded plaques remain clinically silent. In the past 30 years since the term 'vulnerable plaque' was introduced, there have been major advances in the understanding of plaque pathogenesis and pathophysiology, shifting from pursuing features of 'vulnerability' of a specific lesion to the more comprehensive goal of identifying patient 'cardiovascular vulnerability'. It has been also recognized that aside a thin-capped, lipid-rich plaque associated with plaque rupture, acute coronary syndromes (ACS) are also caused by plaque erosion underlying between 25% and 60% of ACS nowadays, by calcified nodule or by functional coronary alterations. While there have been advances in preventive strategies and in pharmacotherapy, with improved agents to reduce cholesterol, thrombosis, and inflammation, events continue to occur in patients receiving optimal medical treatment. Although at present the positive predictive value of imaging precursors of the culprit plaques remains too low for clinical relevance, improving coronary plaque imaging may be instrumental in guiding pharmacotherapy intensity and could facilitate optimal allocation of novel, more aggressive, and costly treatment strategies. Recent technical and diagnostic advances justify continuation of interdisciplinary research efforts to improve cardiovascular prognosis by both systemic and 'local' diagnostics and therapies. The present state-of-the-art document aims to present and critically appraise the latest evidence, developments, and future perspectives in detection, prevention, and treatment of 'high-risk' plaques occurring in 'vulnerable' patients.


Assuntos
Síndrome Coronariana Aguda , Aterosclerose , Doença da Artéria Coronariana , Doença das Coronárias , Placa Aterosclerótica , Morte Súbita Cardíaca/etiologia , Morte Súbita Cardíaca/prevenção & controle , Humanos , Placa Aterosclerótica/diagnóstico por imagem
4.
Eur J Nucl Med Mol Imaging ; 47(12): 2856-2865, 2020 11.
Artigo em Inglês | MEDLINE | ID: mdl-32291511

RESUMO

PURPOSE: Atherosclerotic plaque development and progression signifies a complex inflammatory disease mediated by a multitude of proinflammatory leukocyte subsets. Using single photon emission computed tomography (SPECT) coupled with computed tomography (CT), this study tested a new dual-isotope acquisition protocol to assess each radiotracer's capability to identify plaque phenotype and inflammation levels pertaining to leukocytes expressing leukocyte function-associated antigen-1 (LFA-1) and the leukocyte subset of proinflammatory macrophages expressing somatostatin receptor subtype-2 (SST2). Individual radiotracer uptake was quantified and the presence of corresponding immunohistological cell markers was assessed. METHODS: Human symptomatic carotid plaque segments were obtained from endarterectomy. Segments were incubated in dual-isotope radiotracers [111In]In-DOTA-butylamino-NorBIRT ([111In]In-Danbirt) and [99mTc]Tc-[N0-14,Asp0,Tyr3]-octreotate ([99mTc]Tc-Demotate 2) before scanning with SPECT/CT. Plaque phenotype was classified as pathological intimal thickening, fibrous cap atheroma or fibrocalcific using histology sections based on distinct morphological characteristics. Plaque segments were subsequently immuno-stained with LFA-1 and SST2 and quantified in terms of positive area fraction and compared against the corresponding SPECT images. RESULTS: Focal uptake of co-localising dual-radiotracers identified the heterogeneous distribution of inflamed regions in the plaques which co-localised with positive immuno-stained regions of LFA-1 and SST2. [111In]In-Danbirt and [99mTc]Tc-Demotate 2 uptake demonstrated a significant positive correlation (r = 0.651; p = 0.001). Fibrous cap atheroma plaque phenotype correlated with the highest [111In]In-Danbirt and [99mTc]Tc-Demotate 2 uptake compared with fibrocalcific plaques and pathological intimal thickening phenotypes, in line with the immunohistological analyses. CONCLUSION: A dual-isotope acquisition protocol permits the imaging of multiple leukocyte subsets and the pro-inflammatory macrophages simultaneously in atherosclerotic plaque tissue. [111In]In-Danbirt may have added value for assessing the total inflammation levels in atherosclerotic plaques in addition to classifying plaque phenotype.


Assuntos
Aterosclerose , Placa Aterosclerótica , Aterosclerose/diagnóstico por imagem , Humanos , Isótopos , Placa Aterosclerótica/diagnóstico por imagem , Tomografia Computadorizada com Tomografia Computadorizada de Emissão de Fóton Único , Tomografia Computadorizada de Emissão de Fóton Único
5.
Radiology ; 289(1): 119-125, 2018 10.
Artigo em Inglês | MEDLINE | ID: mdl-30015586

RESUMO

Purpose To study the feasibility of high-frame-rate (HFR) contrast material-enhanced (CE) ultrasound particle image velocimetry (PIV), or echo PIV, in the abdominal aorta. Materials and Methods Fifteen healthy participants (six men; median age, 23 years [age range, 18-34 years]; median body mass index, 20.3 kg/m2 [range, 17.3-24.9 kg/m2]) underwent HFR CE US. US microbubbles were injected at incremental doses (0.25, 0.5, 0.75, and 1.5 mL), with each dose followed by US measurement to determine the optimal dosage. Different US mechanical index values were evaluated (0.09, 0.06, 0.03, and 0.01) in a diverging wave acquisition scheme. PIV analysis was performed via pairwise cross-correlation of all captured images. Participants also underwent phase-contrast MRI. The echo PIV and phase-contrast MRI velocity profiles were compared via calculation of similarity index and relative difference in peak velocity. Results Visualization of the aortic bifurcation with HFR CE US was successful in all participants. Optimal echo PIV results were achieved with the lowest contrast agent dose of 0.25 mL in combination with the lowest mechanical indexes (0.01 or 0.03). Substantial bubble destruction occurred at higher mechanical indexes (≥0.06). Flow patterns were qualitatively similar in the echo PIV and MR images. The echo PIV and MRI velocity profiles showed good agreement (similarity index, 0.98 and 0.99; difference in peak velocity, 8.5% and 17.0% in temporal and spatial profiles, respectively). Conclusion Quantification of blood flow in the human abdominal aorta with US particle image velocimetry (echo PIV) is feasible. Use of echo PIV has potential in the clinical evaluation of aortic disease. © RSNA, 2018 Online supplemental material is available for this article.


Assuntos
Aorta Abdominal/diagnóstico por imagem , Interpretação de Imagem Assistida por Computador/métodos , Reologia/métodos , Ultrassonografia/métodos , Adolescente , Adulto , Feminino , Humanos , Imageamento por Ressonância Magnética , Masculino , Adulto Jovem
6.
J Struct Biol ; 200(1): 28-35, 2017 10.
Artigo em Inglês | MEDLINE | ID: mdl-28838817

RESUMO

Atherosclerotic plaque rupture is the primary trigger of fatal cardiovascular events. Fibrillar collagen in atherosclerotic plaques and their directionality are anticipated to play a crucial role in plaque rupture. This study aimed assessing 3D fiber orientations and architecture in atherosclerotic plaques for the first time. Seven carotid plaques were imaged ex-vivo with a state-of-the-art Diffusion Tensor Imaging (DTI) technique, using a high magnetic field (9.4Tesla) MRI scanner. A 3D spin-echo sequence with uni-polar diffusion sensitizing pulsed field gradients was utilized for DTI and fiber directions were assessed from diffusion tensor measurements. The distribution of the 3D fiber orientations in atherosclerotic plaques were quantified and the principal fiber orientations (circumferential, longitudinal or radial) were determined. Overall, 52% of the fiber orientations in the carotid plaque specimens were closest to the circumferential direction, 34% to the longitudinal direction, and 14% to the radial direction. Statistically no significant difference was measured in the amount of the fiber orientations between the concentric and eccentric plaque sites. However, concentric plaque sites showed a distinct structural organization, where the principally longitudinally oriented fibers were closer to the luminal side and the principally circumferentially oriented fibers were located more abluminally. The acquired unique information on 3D plaque fiber direction will help understanding pathobiological mechanisms of atherosclerotic plaque progression and pave the road to more realistic biomechanical plaque modeling for rupture assessment.


Assuntos
Artérias Carótidas/patologia , Doenças das Artérias Carótidas/patologia , Colágenos Fibrilares/química , Placa Aterosclerótica/patologia , Idoso , Idoso de 80 Anos ou mais , Aterosclerose/diagnóstico por imagem , Aterosclerose/patologia , Artérias Carótidas/diagnóstico por imagem , Doenças das Artérias Carótidas/diagnóstico por imagem , Imagem de Tensor de Difusão , Colágenos Fibrilares/ultraestrutura , Humanos , Imageamento Tridimensional , Masculino , Pessoa de Meia-Idade , Placa Aterosclerótica/diagnóstico por imagem , Estrutura Quaternária de Proteína
7.
Am J Physiol Heart Circ Physiol ; 310(10): H1304-12, 2016 05 15.
Artigo em Inglês | MEDLINE | ID: mdl-26945083

RESUMO

The aim of this study was to determine if reliable patient-specific wall shear stress (WSS) can be computed when diameter-based scaling laws are used to impose the boundary conditions for computational fluid dynamics. This study focused on mildly diseased human coronary bifurcations since they are predilection sites for atherosclerosis. Eight patients scheduled for percutaneous coronary intervention were imaged with angiography. The velocity proximal and distal of a bifurcation was acquired with intravascular Doppler measurements. These measurements were used for inflow and outflow boundary conditions for the first set of WSS computations. For the second set of computations, absolute inflow and outflow ratios were derived from geometry-based scaling laws based on angiography data. Normalized WSS maps per segment were obtained by dividing the absolute WSS by the mean WSS value. Absolute and normalized WSS maps from the measured-approach and the scaled-approach were compared. A reasonable agreement was found between the measured and scaled inflows, with a median difference of 0.08 ml/s [-0.01; 0.20]. The measured and the scaled outflow ratios showed a good agreement: 1.5 percentage points [-19.0; 4.5]. Absolute WSS maps were sensitive to the inflow and outflow variations, and relatively large differences between the two approaches were observed. For normalized WSS maps, the results for the two approaches were equivalent. This study showed that normalized WSS can be obtained from angiography data alone by applying diameter-based scaling laws to define the boundary conditions. Caution should be taken when absolute WSS is assessed from computations using scaled boundary conditions.


Assuntos
Angiografia Coronária , Doença da Artéria Coronariana/diagnóstico por imagem , Circulação Coronária , Vasos Coronários/diagnóstico por imagem , Modelos Cardiovasculares , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Ultrassonografia Doppler , Ultrassonografia de Intervenção/métodos , Velocidade do Fluxo Sanguíneo , Simulação por Computador , Doença da Artéria Coronariana/patologia , Doença da Artéria Coronariana/fisiopatologia , Vasos Coronários/patologia , Vasos Coronários/fisiopatologia , Humanos , Hidrodinâmica , Placa Aterosclerótica , Valor Preditivo dos Testes , Reprodutibilidade dos Testes , Estresse Mecânico
8.
Biomed Eng Online ; 15(Suppl 2): 156, 2016 Dec 28.
Artigo em Inglês | MEDLINE | ID: mdl-28155699

RESUMO

BACKGROUND: Wall shear stress (WSS) is involved in the pathophysiology of atherosclerosis. The correlation between WSS and atherosclerosis can be investigated over time using a WSS-manipulated atherosclerotic mouse model. To determine WSS in vivo, detailed 3D geometry of the vessel network is required. However, a protocol to reconstruct 3D murine vasculature using this animal model is lacking. In this project, we evaluated the adequacy of eXIA 160, a small animal contrast agent, for assessing murine vascular network on micro-CT. Also, a protocol was established for vessel geometry segmentation and WSS analysis. METHODS: A tapering cast was placed around the right common carotid artery (RCCA) of ApoE-/- mice (n = 8). Contrast-enhanced micro-CT was performed using eXIA 160. An innovative local threshold-based segmentation procedure was implemented to reconstruct 3D geometry of the RCCA. The reconstructed RCCA was compared to the vessel geometry using a global threshold-based segmentation method. Computational fluid dynamics was applied to compute the velocity field and WSS distribution along the RCCA. RESULTS: eXIA 160-enhanced micro-CT allowed clear visualization and assessment of the RCCA in all eight animals. No adverse biological effects were observed from the use of eXIA 160. Segmentation using local threshold values generated more accurate RCCA geometry than the global threshold-based approach. Mouse-specific velocity data and the RCCA geometry generated 3D WSS maps with high resolution, enabling quantitative analysis of WSS. In all animals, we observed low WSS upstream of the cast. Downstream of the cast, asymmetric WSS patterns were revealed with variation in size and location between animals. CONCLUSIONS: eXIA 160 provided good contrast to reconstruct 3D vessel geometry and determine WSS patterns in the RCCA of the atherosclerotic mouse model. We established a novel local threshold-based segmentation protocol for RCCA reconstruction and WSS computation. The observed differences between animals indicate the necessity to use mouse-specific data for WSS analysis. For our future work, our protocol makes it possible to study in vivo WSS longitudinally over a growing plaque.


Assuntos
Artérias Carótidas/diagnóstico por imagem , Artérias Carótidas/fisiopatologia , Meios de Contraste/química , Microtomografia por Raio-X/métodos , Animais , Apolipoproteínas E/genética , Velocidade do Fluxo Sanguíneo , Vasos Coronários/patologia , Células Endoteliais/citologia , Endotélio Vascular/fisiopatologia , Feminino , Processamento de Imagem Assistida por Computador , Imageamento Tridimensional , Camundongos , Camundongos Endogâmicos C57BL , Resistência ao Cisalhamento , Estresse Mecânico
9.
Biomed Eng Online ; 15(1): 48, 2016 May 04.
Artigo em Inglês | MEDLINE | ID: mdl-27145748

RESUMO

BACKGROUND: Stress calculations in atherosclerotic coronary vulnerable plaques can aid in predicting coronary cap rupture. In vivo plaque geometry and composition of coronary arteries can merely be obtained via intravascular imaging. Only optical driven imaging techniques have sufficient resolution to visualize the fibrous cap, but due to limited penetration depth deeper components such as the backside of the necrotic core (NC) are generally not visible. The goal of this study was to investigate whether peak cap stresses can be approximated by reconstructing the backside of the NC. METHODS: Manual segmentations of coronary histological cross-sections served as a geometrical ground truth and were obtained from seven patients resulting in 73 NCs. Next, the backside was removed and reconstructed according to an estimation of the relative necrotic core thickness (rNCt). The rNCt was estimated at three locations along the NC angle and based on either group averaged parameters or plaque specific parameters. Stress calculations were performed in both the ground truth geometry and the reconstructed geometries and compared. RESULTS: Good geometrical agreement was found between the ground truth NC and the reconstructed NCs, based on group averaged rNCt estimation and plaque specific rNCt estimation, measuring the NC area difference (25.1 % IQR 14.0-41.3 % and 17.9 % IQR 9.81-32.7 %) and similarity index (0.85 IQR 0.77-0.90 and 0.88 IQR 0.79-0.91). The peak cap stresses obtained with both reconstruction methods showed a high correlation with respect to the ground truth, r(2) = 0.91 and r(2) = 0.95, respectively. For high stress plaques, the peak cap stress difference with respect to the ground truth significantly improved for the NC reconstruction based plaque specific features (6 %) compared to the reconstruction group averaged based (16 %). CONCLUSIONS: In conclusion, good geometry and stress agreement was observed between the ground truth NC geometry and the reconstructed geometries. Although group averaged rNCt estimation seemed to be sufficient for the NC reconstruction and stress calculations, including plaque specific data further improved stress predictions, especially for higher stresses.


Assuntos
Vasos Coronários/patologia , Análise de Elementos Finitos , Placa Aterosclerótica/patologia , Estresse Mecânico , Vasos Coronários/fisiopatologia , Modelos Biológicos , Necrose , Placa Aterosclerótica/fisiopatologia
10.
Biomed Eng Online ; 15(1): 91, 2016 Aug 05.
Artigo em Inglês | MEDLINE | ID: mdl-27495804

RESUMO

BACKGROUND: Coronary hemodynamics and physiology specific for bifurcation lesions was not well understood. To investigate the influence of the bifurcation angle on the intracoronary hemodynamics of side branch (SB) lesions computational fluid dynamics simulations were performed. METHODS: A parametric model representing a left anterior descending-first diagonal coronary bifurcation lesion was created according to the literature. Diameters obeyed fractal branching laws. Proximal and distal main branch (DMB) stenoses were both set at 60 %. We varied the distal bifurcation angles (40°, 55°, and 70°), the flow splits to the DMB and SB (55 %:45 %, 65 %:35 %, and 75 %:25 %), and the SB stenoses (40, 60, and 80 %), resulting in 27 simulations. Fractional flow reserve, defined as the ratio between the mean distal stenosis and mean aortic pressure during maximal hyperemia, was calculated for the DMB and SB (FFRSB) for all simulations. RESULTS: The largest differences in FFRSB comparing the largest and smallest bifurcation angles were 0.02 (in cases with 40 % SB stenosis, irrespective of the assumed flow split) and 0.05 (in cases with 60 % SB stenosis, flow split 55 %:45 %). When the SB stenosis was 80 %, the difference in FFRSB between the largest and smallest bifurcation angle was 0.33 (flow split 55 %:45 %). By describing the ΔPSB-QSB relationship using a quadratic curve for cases with 80 % SB stenosis, we found that the curve was steeper (i.e. higher flow resistance) when bifurcation angle increases (ΔP = 0.451*Q + 0.010*Q (2) and ΔP = 0.687*Q + 0.017*Q (2) for 40° and 70° bifurcation angle, respectively). Our analyses revealed complex hemodynamics in all cases with evident counter-rotating helical flow structures. Larger bifurcation angles resulted in more pronounced helical flow structures (i.e. higher helicity intensity), when 60 or 80 % SB stenoses were present. A good correlation (R(2) = 0.80) between the SB pressure drop and helicity intensity was also found. CONCLUSIONS: Our analyses showed that, in bifurcation lesions with 60 % MB stenosis and 80 % SB stenosis, SB pressure drop is higher for larger bifurcation angles suggesting higher flow resistance (i.e. curves describing the ΔPSB-QSB relationship being steeper). When the SB stenosis is mild (40 %) or moderate (60 %), SB resistance is minimally influenced by the bifurcation angle, with differences not being clinically meaningful. Our findings also highlighted the complex interplay between anatomy, pressure drops, and blood flow helicity in bifurcations.


Assuntos
Estenose Coronária/patologia , Estenose Coronária/fisiopatologia , Vasos Coronários/patologia , Vasos Coronários/fisiopatologia , Reserva Fracionada de Fluxo Miocárdico , Modelos Cardiovasculares , Pressão Sanguínea , Hemodinâmica , Humanos , Hidrodinâmica
11.
Stroke ; 46(8): 2124-8, 2015 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-26081843

RESUMO

BACKGROUND AND PURPOSE: Two approaches to target plaque vulnerability-a histopathologic classification scheme and a biomechanical analysis-were compared and the implications for noninvasive risk stratification of carotid plaques using magnetic resonance imaging were assessed. METHODS: Seventy-five histological plaque cross sections were obtained from carotid endarterectomy specimens from 34 patients (>70% stenosis) and subjected to both a Virmani histopathologic classification (thin fibrous cap atheroma with <0.2-mm cap thickness, presumed vulnerable) and a peak cap stress computation (<140 kPa: presumed stable; >300 kPa: presumed vulnerable). To demonstrate the implications for noninvasive plaque assessment, numeric simulations of a typical carotid magnetic resonance imaging protocol were performed (0.62×0.62 mm(2) in-plane acquired voxel size) and used to obtain the magnetic resonance imaging-based peak cap stress. RESULTS: Peak cap stress was generally associated with histological classification. However, only 16 of 25 plaque cross sections could be labeled as high-risk (peak cap stress>300 kPa and classified as a thin fibrous cap atheroma). Twenty-eight of 50 plaque cross sections could be labeled as low-risk (a peak cap stress<140 kPa and not a thin fibrous cap atheroma), leading to a κ=0.39. 31 plaques (41%) had a disagreement between both classifications. Because of the limited magnetic resonance imaging voxel size with regard to cap thickness, a noninvasive identification of only a group of low-risk, thick-cap plaques was reliable. CONCLUSIONS: Instead of trying to target only vulnerable plaques, a more reliable noninvasive identification of a select group of stable plaques with a thick cap and low stress might be a more fruitful approach to start reducing surgical interventions on carotid plaques.


Assuntos
Estenose das Carótidas/classificação , Estenose das Carótidas/diagnóstico , Imageamento por Ressonância Magnética/classificação , Estresse Mecânico , Estenose das Carótidas/cirurgia , Endarterectomia das Carótidas , Feminino , Humanos , Imageamento por Ressonância Magnética/métodos , Masculino
12.
Magn Reson Med ; 72(1): 188-201, 2014 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-23943090

RESUMO

PURPOSE: Atherosclerotic carotid plaques can be quantified in vivo by MRI. However, the accuracy in segmentation and quantification of components such as the thin fibrous cap (FC) and lipid-rich necrotic core (LRNC) remains unknown due to the lack of a submillimeter scale ground truth. METHODS: A novel approach was taken by numerically simulating in vivo carotid MRI providing a ground truth comparison. Upon evaluation of a simulated clinical protocol, MR readers segmented simulated images of cross-sectional plaque geometries derived from histological data of 12 patients. RESULTS: MR readers showed high correlation (R) and intraclass correlation (ICC) in measuring the luminal area (R = 0.996, ICC = 0.99), vessel wall area (R = 0.96, ICC = 0.94) and LRNC area (R = 0.95, ICC = 0.94). LRNC area was underestimated (mean error, -24%). Minimum FC thickness showed a mediocre correlation and intraclass correlation (R = 0.71, ICC = 0.69). CONCLUSION: Current clinical MRI can quantify carotid plaques but shows limitations for thin FC thickness quantification. These limitations could influence the reliability of carotid MRI for assessing plaque rupture risk associated with FC thickness. Overall, MRI simulations provide a feasible methodology for assessing segmentation and quantification accuracy, as well as for improving scan protocol design.


Assuntos
Doenças das Artérias Carótidas/diagnóstico , Interpretação de Imagem Assistida por Computador/métodos , Angiografia por Ressonância Magnética/métodos , Placa Aterosclerótica/diagnóstico , Simulação por Computador , Meios de Contraste , Humanos , Lipídeos/análise , Necrose , Compostos Organometálicos , Razão Sinal-Ruído
13.
NMR Biomed ; 27(7): 826-34, 2014 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-24817676

RESUMO

Wall shear stress (WSS) is involved in many pathophysiological processes related to cardiovascular diseases, and knowledge of WSS may provide vital information on disease progression. WSS is generally quantified with computational fluid dynamics (CFD), but can also be calculated using phase contrast MRI (PC-MRI) measurements. In this study, our objectives were to calculate WSS on the entire luminal surface of human carotid arteries using PC-MRI velocities (WSSMRI ) and to compare it with WSS based on CFD (WSSCFD ). Six healthy volunteers were scanned with a 3 T MRI scanner. WSSCFD was calculated using a generalized flow waveform with a mean flow equal to the mean measured flow. WSSMRI was calculated by estimating the velocity gradient along the inward normal of each mesh node on the luminal surface. Furthermore, WSS was calculated for a down-sampled CFD velocity field mimicking the MRI resolution (WSSCFDlowres ). To ensure minimum temporal variation, WSS was analyzed only at diastole. The patterns of WSSCFD and WSSMRI were compared by quantifying the overlap between low, medium and high WSS tertiles. Finally, WSS directions were compared by calculating the angles between the WSSCFD and WSSMRI vectors. WSSMRI magnitude was found to be lower than WSSCFD (0.62 ± 0.18 Pa versus 0.88 ± 0.30 Pa, p < 0.01) but closer to WSSCFDlowres (0.56 ± 0.18 Pa, p < 0.01). WSSMRI patterns matched well with those of WSSCFD. The overlap area was 68.7 ± 4.4% in low and 69.0 ± 8.9% in high WSS tertiles. The angles between WSSMRI and WSSCFD vectors were small in the high WSS tertiles (20.3 ± 8.2°), but larger in the low WSS tertiles (65.6 ± 17.4°). In conclusion, although WSSMRI magnitude was lower than WSSCFD , the spatial WSS patterns at diastole, which are more relevant to the vascular biology, were similar. PC-MRI-based WSS has potential to be used in the clinic to indicate regions of low and high WSS and the direction of WSS, especially in regions of high WSS.


Assuntos
Artérias Carótidas/patologia , Artérias Carótidas/fisiopatologia , Hidrodinâmica , Imagem Cinética por Ressonância Magnética/métodos , Estresse Mecânico , Adulto , Velocidade do Fluxo Sanguíneo , Circulação Coronária , Diástole , Saúde , Humanos
14.
J Biomech Eng ; 136(2): 021015, 2014 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-24317274

RESUMO

Biomechanical finite element analysis (FEA) based on in vivo carotid magnetic resonance imaging (MRI) can be used to assess carotid plaque vulnerability noninvasively by computing peak cap stress. However, the accuracy of MRI plaque segmentation and the influence this has on FEA has remained unreported due to the lack of a reliable submillimeter ground truth. In this study, we quantify this influence using novel numerical simulations of carotid MRI. Histological sections from carotid plaques from 12 patients were used to create 33 ground truth plaque models. These models were subjected to numerical computer simulations of a currently used clinically applied 3.0 T T1-weighted black-blood carotid MRI protocol (in-plane acquisition voxel size of 0.62 × 0.62 mm2) to generate simulated in vivo MR images from a known underlying ground truth. The simulated images were manually segmented by three MRI readers. FEA models based on the MRI segmentations were compared with the FEA models based on the ground truth. MRI-based FEA model peak cap stress was consistently underestimated, but still correlated (R) moderately with the ground truth stress: R = 0.71, R = 0.47, and R = 0.76 for the three MRI readers respectively (p < 0.01). Peak plaque stretch was underestimated as well. The peak cap stress in thick-cap, low stress plaques was substantially more accurately and precisely predicted (error of -12 ± 44 kPa) than the peak cap stress in plaques with caps thinner than the acquisition voxel size (error of -177 ± 168 kPa). For reliable MRI-based FEA to compute the peak cap stress of carotid plaques with thin caps, the current clinically used in-plane acquisition voxel size (∼0.6 mm) is inadequate. FEA plaque stress computations would be considerably more reliable if they would be used to identify thick-cap carotid plaques with low stresses instead.


Assuntos
Artérias Carótidas/fisiopatologia , Estenose das Carótidas/patologia , Estenose das Carótidas/fisiopatologia , Técnicas de Imagem por Elasticidade/métodos , Interpretação de Imagem Assistida por Computador/métodos , Angiografia por Ressonância Magnética/métodos , Modelos Cardiovasculares , Idoso , Velocidade do Fluxo Sanguíneo , Artérias Carótidas/patologia , Simulação por Computador , Módulo de Elasticidade , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Resistência ao Cisalhamento
15.
Ann Biomed Eng ; 52(8): 2151-2161, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-38664333

RESUMO

Thrombus computed tomography (CT) imaging characteristics may correspond with thrombus mechanical properties and thus predict thrombectomy success. The impact of red blood cell (RBC) content on these properties (imaging and mechanics) has been widely studied. However, the additional effect of platelets has not been considered. The objective of the current study was to examine the individual and combined effects of blood clot RBC and platelet content on resultant CT imaging and mechanical characteristics. Human blood clot analogues were prepared from a combination of preselected RBC volumes and platelet concentrations to decouple their contributions. The resulting clot RBC content (%) and platelet content (%) were determined using Martius Scarlet Blue and CD42b staining, respectively. Non-contrast and contrast-enhanced CT (NCCT and CECT) scans were performed to measure the clot densities. CECT density increase was taken as a proxy for clinical perviousness. Unconfined compressive mechanics were analysed by performing 10 cycles of 80% strain. RBC content is the major determinant of clot NCCT density. However, additional consideration of the platelet content improves the association. CECT density increase is influenced by clot platelet and not RBC content. Platelet content is the dominant component driving clot stiffness, especially at high strains. Both RBC and platelet content contribute to the clot's viscoelastic and plastic compressive properties. The current in vitro results suggest that CT density is reflective of RBC content and subsequent clot viscoelasticity and plasticity, and that perviousness reflects the clot's platelet content and subsequent stiffness. However, these indications should be confirmed in a clinical stroke cohort.


Assuntos
Plaquetas , Eritrócitos , Trombose , Tomografia Computadorizada por Raios X , Humanos , Plaquetas/fisiologia , Trombose/diagnóstico por imagem
16.
Ann Biomed Eng ; 51(8): 1759-1768, 2023 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-37071278

RESUMO

Endovascular thrombectomy procedures are significantly influenced by the mechanical response of thrombi to the multi-axial loading imposed during retrieval. Compression tests are commonly used to determine compressive ex vivo thrombus and clot analogue stiffness. However, there is a shortage of data in tension. This study compares the tensile and compressive response of clot analogues made from the blood of healthy human donors in a range of compositions. Citrated whole blood was collected from six healthy human donors. Contracted and non-contracted fibrin clots, whole blood clots and clots reconstructed with a range of red blood cell (RBC) volumetric concentrations (5-80%) were prepared under static conditions. Both uniaxial tension and unconfined compression tests were performed using custom-built setups. Approximately linear nominal stress-strain profiles were found under tension, while strong strain-stiffening profiles were observed under compression. Low- and high-strain stiffness values were acquired by applying a linear fit to the initial and final 10% of the nominal stress-strain curves. Tensile stiffness values were approximately 15 times higher than low-strain compressive stiffness and 40 times lower than high-strain compressive stiffness values. Tensile stiffness decreased with an increasing RBC volume in the blood mixture. In contrast, high-strain compressive stiffness values increased from 0 to 10%, followed by a decrease from 20 to 80% RBC volumes. Furthermore, inter-donor differences were observed with up to 50% variation in the stiffness of whole blood clot analogues prepared in the same manner between healthy human donors.


Assuntos
Tromboembolia , Trombose , Humanos , Trombectomia , Eritrócitos , Suporte de Carga/fisiologia , Força Compressiva/fisiologia
17.
PLoS One ; 18(11): e0293456, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37956141

RESUMO

BACKGROUND: Clot composition, contraction, and mechanical properties are likely determinants of endovascular thrombectomy success. A pre-interventional estimation of these properties is hypothesized to aid in selecting the most suitable treatment for different types of thrombi. Here we determined the association between the aforementioned properties and computed tomography (CT) characteristics using human blood clot analogues. METHODS: Clot analogues were prepared from the blood of 4 healthy human donors with 5 red blood cell (RBC) volume suspensions: 0%, 20%, 40%, 60% and 80% RBCs. Contraction was measured as the weight of the contracted clots as a percentage of the original suspension. The clots were imaged using CT with and without contrast to quantify clot density and density increase. Unconfined compression was performed to determine the high strain compressive stiffness. The RBC content was analysed using H&E staining. RESULTS: The 5 RBC suspensions formed only two groups of clots, fibrin-rich (0% RBCs) and RBC-rich (>90% RBCs), as determined by histology. The density of the fibrin-rich clots was significantly lower (31-38HU) compared to the RBC-rich clots (72-89HU), and the density increase of the fibrin-rich clots was significantly higher (82-127HU) compared to the RBC-rich clots (3-17HU). The compressive stiffness of the fibrin-rich clots was higher (178-1624 kPa) than the stiffness of the RBC-rich clots (6-526 kPa). Additionally, the degree of clot contraction was higher for the fibrin-rich clots (89-96%) compared to the RBC-rich clots (11-77%). CONCLUSIONS: CT imaging clearly reflects clot RBC content and seems to be related to the clot contraction and stiffness. CT imaging might be a useful tool in predicting the thrombus characteristics. However, future studies should confirm these findings by analysing clots with intermediate RBC and platelet content.


Assuntos
Tromboembolia , Trombose , Humanos , Trombose/patologia , Tomografia Computadorizada por Raios X/métodos , Trombectomia/métodos , Tromboembolia/patologia , Fibrina , Eritrócitos/patologia
18.
Cardiovasc Res ; 119(4): 1021-1029, 2023 05 02.
Artigo em Inglês | MEDLINE | ID: mdl-36575921

RESUMO

AIMS: Low wall shear stress (WSS) is acknowledged to play a role in plaque development through its influence on local endothelial function. Also, lipid-rich plaques (LRPs) are associated with endothelial dysfunction. However, little is known about the interplay between WSS and the presence of lipids with respect to plaque progression. Therefore, we aimed to study the differences in WSS-related plaque progression between LRPs, non-LRPs, or plaque-free regions in human coronary arteries. METHODS AND RESULTS: In the present single-centre, prospective study, 40 patients who presented with an acute coronary syndrome successfully underwent near-infrared spectroscopy intravascular ultrasound (NIRS-IVUS) and optical coherence tomography (OCT) of at least one non-culprit vessel at baseline and completed a 1-year follow-up. WSS was computed applying computational fluid dynamics to a three-dimensional reconstruction of the coronary artery based on the fusion of the IVUS-segmented lumen with a CT-derived centreline, using invasive flow measurements as boundary conditions. For data analysis, each artery was divided into 1.5 mm/45° sectors. Plaque growth based on IVUS-derived percentage atheroma volume change was compared between LRPs, non-LRPs, and plaque-free wall segments, as assessed by both OCT and NIRS. Both NIRS- and OCT-detected lipid-rich sectors showed a significantly higher plaque progression than non-LRPs or plaque-free regions. Exposure to low WSS was associated with a higher plaque progression than exposure to mid or high WSS, even in the regions classified as a plaque-free wall. Furthermore, low WSS and the presence of lipids had a synergistic effect on plaque growth, resulting in the highest plaque progression in lipid-rich regions exposed to low shear stress. CONCLUSION: This study demonstrates that NIRS- and OCT-detected lipid-rich regions exposed to low WSS are subject to enhanced plaque growth over a 1-year follow-up. The presence of lipids and low WSS proves to have a synergistic effect on plaque growth.


Assuntos
Doença da Artéria Coronariana , Placa Aterosclerótica , Humanos , Vasos Coronários/diagnóstico por imagem , Doença da Artéria Coronariana/diagnóstico por imagem , Espectroscopia de Luz Próxima ao Infravermelho , Tomografia de Coerência Óptica , Estudos Prospectivos , Lipídeos
19.
J Mech Behav Biomed Mater ; 126: 104996, 2022 02.
Artigo em Inglês | MEDLINE | ID: mdl-34864574

RESUMO

OBJECTIVE: Plaque rupture in atherosclerotic carotid arteries is a main cause of ischemic stroke and it is correlated with high plaque stresses. Hence, analyzing stress patterns is essential for plaque specific rupture risk assessment. However, the critical information of the multicomponent material properties of atherosclerotic carotid arteries is still lacking greatly. This work aims to characterize component-wise material properties of atherosclerotic human carotid arteries under (almost) physiological loading conditions. METHODS: An inverse finite element modeling (iFEM) framework was developed to characterize fibrous intima and vessel wall material properties of 13 cross sections from five carotids. The novel pipeline comprised ex-vivo inflation testing, pre-clinical high frequency ultrasound for deriving plaque deformations, pre-clinical high-magnetic field magnetic resonance imaging, finite element modeling, and a sample efficient machine learning based Bayesian Optimization. RESULTS: The nonlinear Yeoh constants for the fibrous intima and wall layers were successfully obtained. The optimization scheme of the iFEM reached the global minimum with a mean error of 3.8% in 133 iterations on average. The uniqueness of the results were confirmed with the inverted Gaussian Process (GP) model trained during the iFEM protocol. CONCLUSION: The developed iFEM approach combined with the inverted GP model successfully predicted component-wise material properties of intact atherosclerotic human carotids ex-vivo under physiological-like loading conditions. SIGNIFICANCE: We developed a novel iFEM framework for the nonlinear, component-wise material characterization of atherosclerotic arteries and utilized it to obtain human atherosclerotic carotid material properties. The developed iFEM framework has great potential to be advanced for patient-specific in-vivo application.


Assuntos
Artérias Carótidas , Placa Aterosclerótica , Teorema de Bayes , Artérias Carótidas/diagnóstico por imagem , Análise de Elementos Finitos , Humanos , Placa Aterosclerótica/diagnóstico por imagem , Ultrassonografia
20.
J Mech Behav Biomed Mater ; 135: 105462, 2022 11.
Artigo em Inglês | MEDLINE | ID: mdl-36116343

RESUMO

Mechanical thrombectomy (MT) treatment of acute ischemic stroke (AIS) patients typically involves use of stent retrievers or aspiration catheters alone or in combination. For in silico trials of AIS patients, it is crucial to incorporate the possibility of thrombus fragmentation during the intervention. This study focuses on two aspects of the thrombectomy simulation: i) Thrombus fragmentation on the basis of a failure model calibrated with experimental tests on clot analogs; ii) the combined stent-retriever and aspiration catheter MT procedure is modeled by adding both the proximal balloon guide catheter and the distal access catheter. The adopted failure criterion is based on maximum principal stress threshold value. If elements of the thrombus exceed this criterion during the retrieval simulation, then they are deleted from the calculation. Comparison with in-vitro tests indicates that the simulation correctly reproduces the procedures predicting thrombus fragmentation in the case of red blood cells rich thrombi, whereas non-fragmentation is predicted for fibrin-rich thrombi. Modeling of balloon guide catheter prevents clot fragments' embolization to further distal territories during MT procedure.


Assuntos
AVC Isquêmico , Trombose , Fibrina , Humanos , Stents , Trombectomia/efeitos adversos , Trombectomia/métodos , Trombose/terapia , Resultado do Tratamento