Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros

Base de dados
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
J Magn Reson Imaging ; 25(3): 548-56, 2007 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-17279503

RESUMO

PURPOSE: To integrate a high intensity focused ultrasound (HIFU) transducer with an MR receiver coil for endocavitary MR-guided thermal ablation of localized pelvic lesions. MATERIALS AND METHODS: A hollow semicylindrical probe (diameter 3.2 cm) with a rectangular upper surface (7.2 cm x 3.2 cm) was designed to house a HIFU transducer and enable acoustic contact with an intraluminal wall. The probe was distally rounded to ease endocavitary insertion and was proximally tapered to a 1.5-cm diameter cylindrical handle through which the irrigation tubes (for transducer cooling) and electrical connections were passed. MR compatibility of piezoceramic and piezocomposite transducers was assessed using gradient-echo (GRE) sequences. The radiofrequency (RF) tuning of identical 6.5 cm x 2.5 cm rectangular receiver coils on the upper surface of the probe was adjusted to compensate for the presence of the conductive components of the HIFU transducers. A T1-weighted (T1-W) sliding window dual-echo GRE sequence monitored phase changes in the focal zone of each transducer. High-intensity (2400 W/cm(-2)), short duration (<1.5 seconds) exposures produced subtherapeutic temperature rises. RESULTS: For T1-W images, signal-to-noise ratio (SNR) improved by 40% as a result of quartering the conductive surface of the piezoceramic transducer. A piezocomposite transducer showed a further 28% improvement. SNRs for an endocavitary coil in the focal plane of the HIFU trans-ducer (4 cm from its face) were three times greater than from a phased body array coil. Local shimming improved uniformity of phase images. Phase changes were detected at subtherapeutic exposures. CONCLUSION: We combined a HIFU transducer with an MR receiver coil in an endocavitary probe. SNRs were improved by quartering the conductive surface of the piezoceramic. Further improvement was achieved with a piezocomposite transducer. A phase change was seen on MR images during both subtherapeutic and therapeutic HIFU exposures.


Assuntos
Ablação por Cateter/instrumentação , Fígado , Imageamento por Ressonância Magnética/instrumentação , Imagens de Fantasmas , Terapia por Ultrassom/instrumentação , Animais , Artefatos , Calibragem , Ablação por Cateter/normas , Bovinos , Desenho de Equipamento/métodos , Temperatura Alta , Aumento da Imagem/métodos , Imageamento por Ressonância Magnética/métodos , Temperatura , Transdutores , Terapia por Ultrassom/métodos
2.
J Magn Reson Imaging ; 18(1): 131-5, 2003 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-12815649

RESUMO

PURPOSE: To construct an inductively-coupled receiver coil system for use with a magnetic resonance (MR) compatible endoscope, and to evaluate its use in a pilot group of patients with esophageal cancer. MATERIALS AND METHODS: An inductively-coupled coil system, comprising a saddle geometry cylindrical receiver coil fitted as a sleeve around the endoscope tip and a pick-up coil housed within a channel of an MR-compatible endoscope, was designed and developed for use at 0.5 T. Twenty-three patients with esophageal cancer were recruited for MR endoscopy. In 17 cases, the endoscopic coil system was used in conjunction with an external surface coil in order to obtain information from the surrounding mediastinum. The examination took 40-50 minutes. RESULTS: MR imaging using the inductively-coupled endoscopic coil was successful in 21 cases (one failed intubation and one artifact from unrelated external source). Image artifact was largely due to respiration and global patient motion in sedated individuals undergoing endoscopy. CONCLUSION: Inductively-coupled coil systems may be used with endoscopes to allow improved safety through increased patient-system isolation and detachability of coils and electronics for repair or replacement with coils tuned for different frequencies.


Assuntos
Endoscópios , Neoplasias Esofágicas/diagnóstico , Imageamento por Ressonância Magnética/instrumentação , Adulto , Idoso , Desenho de Equipamento , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Imagens de Fantasmas , Projetos Piloto
3.
Radiology ; 225(2): 433-9, 2002 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-12409577

RESUMO

PURPOSE: To compare, on high-spatial-resolution magnetic resonance (MR) images, the presence and distribution of the paravaginal fascia in continent women and in those with genuine stress incontinence (GSI) to establish its role in the pathophysiology of GSI. MATERIALS AND METHODS: Eleven continent reference subjects and 10 GSI patients underwent MR imaging with a specifically designed endovaginal receiver coil. A urinary continence questionnaire and urogynecologic clinical examination had been completed. GSI was diagnosed with urodynamic tests. Paravaginal fascial tissue distribution was determined, and the paravaginal fascial volume (PFV) anteriorly associated with the urethra was measured. Retropubic urethral length (UL) in the supine position at rest was compared with its total length and expressed as a percentage ratio. Comparisons of urethral PFV and retropubic UL between reference subjects and the GSI patients were performed by means of two-sample t tests with unequal variances because data were parametric by means of the Shapiro-Francia W' test for normal data. RESULTS: The paravaginal fascia (connective tissue that contained venous plexus) was a consistent MR imaging feature in all women. Mean urethral PFV was 5.3 cm(3) +/- 0.6 (SD) in reference subjects compared with 3.5 cm(3) +/- 2.0 in GSI patients (P =.017). The ratio of the retropubic UL to its total length was 82.6% +/- 7.4 in reference subjects compared with 57.4% +/- 9.8 in GSI patients (P <.001). There was a weak correlation between urethral PFV and retropubic UL (r = 0.46). CONCLUSION: There is a significant association between urethral PFV and continence status. GSI patients have a reduced urethral PFV, and greater than 40% of their urethral length lies below the pubis in the supine position at rest. However, the effects of age and hormonal status on urethral PFV remain to be evaluated.


Assuntos
Fáscia/patologia , Imageamento por Ressonância Magnética/instrumentação , Uretra/patologia , Incontinência Urinária por Estresse/diagnóstico , Vagina/patologia , Adulto , Idoso , Desenho de Equipamento , Feminino , Humanos , Aumento da Imagem , Processamento de Imagem Assistida por Computador , Pessoa de Meia-Idade , Valores de Referência , Sensibilidade e Especificidade , Software , Veias/patologia
4.
Radiology ; 230(1): 281-6, 2004 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-14645876

RESUMO

The authors defined esophageal anatomy and evaluated esophageal cancer staging in a pilot group by comparing endoscopic magnetic resonance (MR) imaging results with pathologic and endoscopic ultrasonographic (US) results when available. A porcine esophagus, one volunteer, and 23 patients suspected of having esophageal cancer were imaged at 0.5 T. MR imaging was successful in 21 patients. Eight of these patients underwent esophagectomy (one after chemotherapy, which invalidated comparison with MR imaging; another did not undergo lymphadenectomy) and one underwent laparoscopy and nodal staging only; eight underwent US. When verified with pathologic staging, endoscopic MR imaging was accurate in six of seven patients (T stage) and five of six patients (N stage; nodal areas too obscured by artifact for comparison in one case). MR imaging and US results concurred in seven of eight (T stage) and five of eight (N stage) patients. No complications were observed. Endoscopic MR imaging is safe and probably comparable to endoscopic US, but with a tendency to overstage the disease.


Assuntos
Neoplasias Esofágicas/patologia , Esofagoscopia , Imageamento por Ressonância Magnética , Adulto , Idoso , Animais , Desenho de Equipamento , Neoplasias Esofágicas/diagnóstico por imagem , Esofagoscópios , Feminino , Humanos , Técnicas In Vitro , Imageamento por Ressonância Magnética/métodos , Masculino , Pessoa de Meia-Idade , Estadiamento de Neoplasias , Projetos Piloto , Suínos , Ultrassonografia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA