Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 80
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
Perfusion ; : 2676591241241422, 2024 Mar 27.
Artigo em Inglês | MEDLINE | ID: mdl-38537032

RESUMO

PURPOSE: To investigate the impact of direct aortic cannulation (DAC) versus femoral arterial cannulation (FAC) on clinical outcomes of surgery for acute type A aortic dissection. METHODS: PubMed/MEDLINE, Scopus, and Cochrane Central Register of Controlled Trials were searched until August 25, 2023, to conduct a meta-analysis. Primary endpoints of the study were operative mortality and postoperative stroke. Secondary endpoints were cardiopulmonary bypass time, myocardial ischemic time, hypothermic circulatory arrest time, temporary neurological dysfunction (TND), combined stroke and TND, re-exploration for bleeding, and need for renal replacement therapy. A random-effect model was used to estimate the pooled effect size, and a leave-one-out method was used for the primary endpoints for sensitivity analysis. RESULTS: 15 studies met our eligibility criteria, including a total of 7941 samples. Operative mortality was significantly lower in the DAC group with a pooled odds ratio (OR) of 0.72 [95% confidence interval (CI): 0.61-0.85)]. Incidence of postoperative stroke was also lower in the DAC group with a pooled OR of 0.79 (95% CI: 0.66-0.94). However, after excluding one study with the greatest weight, the difference became nonsignificant. DAC was also associated with a lower incidence of postoperative TND, and re-exploration for bleeding with a pooled OR of 0.52 (95% CI: 0.37-0.73), and 0.60 (95% CI: 0.47-0.77), respectively. CONCLUSIONS: This meta-analysis showed that patients who underwent ATAAD repair with DAC had a lower incidence of operative mortality, postoperative stroke, TND, and re-exploration for bleeding compared to those who underwent FAC.

2.
Catheter Cardiovasc Interv ; 101(7): 1203-1213, 2023 06.
Artigo em Inglês | MEDLINE | ID: mdl-37070459

RESUMO

BACKGROUND: Permanent pacemaker implantation (PPI) after transcatheter aortic valve implantation (TAVI) is associated with higher risk of mortality and rehospitalization for heart failure. Efforts to prevent conduction abnormalities (CA) requiring PPI after TAVI should be made. The membranous septum (MS) length and its interaction with implantation depth (ID-ΔMSID) could provide useful information about the risk of CA/PPI following TAVI. OBJECTIVES: To identify MS length and ΔMSID as predictors of CA/PPI following TAVI. METHODS: Study-level meta-analysis of studies published by September 30, 2022. RESULTS: Eighteen studies met our eligibility including 5740 patients. Shorter MS length was associated with a significantly higher risk of CA/PPI (per 1 mm decrease: odds ratio [OR] 1.60, 95% confidence interval [CI] 1.28-1.99, p < 0.001). Similarly, lower ΔMSID was associated with a significantly higher risk of CA/PPI (per 1 mm decrease: OR 1.75, 95% CI 1.32-2.31, p < 0.001). Meta-regression analyses revealed a statistically significant modulation of the effect of shorter MS length and lower ΔMSID on the outcome (CA/PPI) by balloon postdilatation (positive regression coefficients with p < 0.001); with increasing use of balloon postdilatation, the effect of shorter MS length and lower ΔMSID on the outcome increased. MS length and ΔMSID demonstrated excellent discriminative abilities, with diagnostic ORs equaling 9.49 (95% CI 4.73-19.06), and 7.19 (95% CI 3.31-15.60), respectively. CONCLUSION: Considering that short MS length and low ΔMSID are associated with higher risk of CA and PPI, we should include measurement of MS length in the pre-TAVI planning with MDCT and try to establish optimal ID values before the procedure to avoid CA/PPI.


Assuntos
Estenose da Valva Aórtica , Próteses Valvulares Cardíacas , Marca-Passo Artificial , Substituição da Valva Aórtica Transcateter , Humanos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Fatores de Risco , Resultado do Tratamento , Tomografia Computadorizada por Raios X , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia
3.
J Endovasc Ther ; 30(6): 885-891, 2023 12.
Artigo em Inglês | MEDLINE | ID: mdl-35766367

RESUMO

BACKGROUND: Vascular complications are a cause of increased morbidity and mortality when performing percutaneous procedures requiring large-bore arterial access. MANTA vascular closure device (VCD) is currently the only large-bore VCD using an intraluminal foot plate and an extraluminal collagen plug. The traditional depth locator approach might be compromised in; emergent cases without the required measurements, cases of hematoma formation, or other patient, procedure, or operator-specific variables. Furthermore, this technique can be used for postclosure in cases without the required measurement of depth. We describe vascular outcomes using fluoroscopy (fluoroscopic DOT technique) rather than traditional depth locator approach for vascular closure with the MANTA VCD. METHODS: Fifty patients who underwent transcatheter aortic valve implantation (TAVI) were retrospectively analyzed using fluoroscopic DOT technique with 18F MANTA VCD between May and August 2021. All patients >18 years of age who qualified for transfemoral TAVI were included. Access was obtained with ultrasound guidance with vessel diameter of at least > 6 mm and free from anterior vessel wall calcification. Patient related factors and primary outcomes of access site bleeding and acute flow-limited limb ischemia requiring intervention were prospectively analyzed. Furthermore, 1 patient who failed hemostasis with suture-mediated VCD had successful hemostasis with fluoroscopic DOT technique as dry postclosure after balloon aortic valvuloplasty. RESULTS: In total, 50 patients were analyzed with a mean age of 81 years and majority were male (56%). Majority had comorbidities of hypertension (88%) and hyperlipidemia (94%), 24% had peripheral arterial disease, 38% coronary artery disease, and 58% were former smokers. Importantly, 40% were obese with an average body mass index (BMI) of 29 kg/m2. There were no bleeding or ischemic limb complications post MANTA VCD deployment using the fluoroscopic DOT technique. Furthermore, none of the patients required peripheral intervention from index procedure to 1 month post verified during their 1-month post TAVR follow-up. CONCLUSION: Fluoroscopic DOT technique using the MANTA VCD is highly reproducible and allows hemostasis in a predictable manner for procedures requiring large-bore arterial access in the absence of MANTA depth measurement.


Assuntos
Estenose da Valva Aórtica , Cateterismo Periférico , Dispositivos de Oclusão Vascular , Humanos , Masculino , Feminino , Idoso de 80 Anos ou mais , Dispositivos de Oclusão Vascular/efeitos adversos , Técnicas Hemostáticas/efeitos adversos , Estudos Retrospectivos , Cateterismo Periférico/efeitos adversos , Resultado do Tratamento , Artéria Femoral/diagnóstico por imagem , Artéria Femoral/cirurgia , Hemorragia/etiologia , Estenose da Valva Aórtica/complicações , Estenose da Valva Aórtica/cirurgia
4.
N Engl J Med ; 380(18): 1695-1705, 2019 05 02.
Artigo em Inglês | MEDLINE | ID: mdl-30883058

RESUMO

BACKGROUND: Among patients with aortic stenosis who are at intermediate or high risk for death with surgery, major outcomes are similar with transcatheter aortic-valve replacement (TAVR) and surgical aortic-valve replacement. There is insufficient evidence regarding the comparison of the two procedures in patients who are at low risk. METHODS: We randomly assigned patients with severe aortic stenosis and low surgical risk to undergo either TAVR with transfemoral placement of a balloon-expandable valve or surgery. The primary end point was a composite of death, stroke, or rehospitalization at 1 year. Both noninferiority testing (with a prespecified margin of 6 percentage points) and superiority testing were performed in the as-treated population. RESULTS: At 71 centers, 1000 patients underwent randomization. The mean age of the patients was 73 years, and the mean Society of Thoracic Surgeons risk score was 1.9% (with scores ranging from 0 to 100% and higher scores indicating a greater risk of death within 30 days after the procedure). The Kaplan-Meier estimate of the rate of the primary composite end point at 1 year was significantly lower in the TAVR group than in the surgery group (8.5% vs. 15.1%; absolute difference, -6.6 percentage points; 95% confidence interval [CI], -10.8 to -2.5; P<0.001 for noninferiority; hazard ratio, 0.54; 95% CI, 0.37 to 0.79; P = 0.001 for superiority). At 30 days, TAVR resulted in a lower rate of stroke than surgery (P = 0.02) and in lower rates of death or stroke (P = 0.01) and new-onset atrial fibrillation (P<0.001). TAVR also resulted in a shorter index hospitalization than surgery (P<0.001) and in a lower risk of a poor treatment outcome (death or a low Kansas City Cardiomyopathy Questionnaire score) at 30 days (P<0.001). There were no significant between-group differences in major vascular complications, new permanent pacemaker insertions, or moderate or severe paravalvular regurgitation. CONCLUSIONS: Among patients with severe aortic stenosis who were at low surgical risk, the rate of the composite of death, stroke, or rehospitalization at 1 year was significantly lower with TAVR than with surgery. (Funded by Edwards Lifesciences; PARTNER 3 ClinicalTrials.gov number, NCT02675114.).


Assuntos
Estenose da Valva Aórtica/cirurgia , Valva Aórtica/cirurgia , Implante de Prótese de Valva Cardíaca/métodos , Próteses Valvulares Cardíacas , Readmissão do Paciente/estatística & dados numéricos , Complicações Pós-Operatórias/epidemiologia , Substituição da Valva Aórtica Transcateter/instrumentação , Idoso , Estenose da Valva Aórtica/complicações , Estenose da Valva Aórtica/mortalidade , Fibrilação Atrial/etiologia , Feminino , Implante de Prótese de Valva Cardíaca/efeitos adversos , Humanos , Estimativa de Kaplan-Meier , Tempo de Internação , Masculino , Desenho de Prótese , Fatores de Risco , Acidente Vascular Cerebral/epidemiologia , Acidente Vascular Cerebral/etiologia , Substituição da Valva Aórtica Transcateter/efeitos adversos
5.
Catheter Cardiovasc Interv ; 100(4): 667-673, 2022 10.
Artigo em Inglês | MEDLINE | ID: mdl-35907255

RESUMO

Vacuum assisted aspiration with the AngioVac system has been well described for; right sided endocarditis, venous thrombus, lead related infection/thrombus aspiration and right sided cardiac mass evacuation. Percutaneous transeptal debulking with AngioVac for mitral valve endocarditis (MVE) in the inoperable or high surgical risk patient has not been well defined. A significant proportion of high/prohibitive surgical risk patients with left sided infective endocarditis (IE) are not offered valve surgery as patients in the acute active phase of IE have a high surgical mortality. Nonetheless, sequala of acute IE ie stroke, sepsis or hemodynamic instability in itself is associated with high morbidity and mortality without surgical treatment. A case report of an inoperable patient with methicillin sensitive staphylococcus aureus MVE who was offered MV vegetation debulking with the AngioVac Gen3 C 180 MV system is described. Preprocedural planning with attention to; optimal transeptal height puncture, use of sentinel cerebral protection device to decrease risk of procedure related cerebral embolism and venous extracorporeal membrane cannula, rather than arterial cannula for reinfusion, is described to avoid large bore arterial access related vascular complications. Further studies in a randomized manner are warranted to test these procedural techniques and determine outcomes of percutaneous aspiration of left sided IE with the AngioVac system in this highrisk inoperable cohort of patients.


Assuntos
Endocardite Bacteriana , Endocardite , Trombose , Procedimentos Cirúrgicos de Citorredução , Endocardite/cirurgia , Endocardite Bacteriana/complicações , Endocardite Bacteriana/diagnóstico , Endocardite Bacteriana/cirurgia , Humanos , Meticilina , Valva Mitral/diagnóstico por imagem , Valva Mitral/cirurgia , Resultado do Tratamento
6.
Circulation ; 141(19): 1527-1537, 2020 05 12.
Artigo em Inglês | MEDLINE | ID: mdl-32272848

RESUMO

BACKGROUND: This study aimed to compare echocardiographic findings in low-risk patients with severe aortic stenosis after surgical aortic valve replacement (SAVR) or transcatheter aortic valve replacement (TAVR). METHODS: The PARTNER 3 trial (Placement of Aortic Transcatheter Valves) randomized 1000 patients with severe aortic stenosis and low surgical risk to undergo either transfemoral TAVR with the balloon-expandable SAPIEN 3 valve or SAVR. Transthoracic echocardiograms obtained at baseline and at 30 days and 1 year after the procedure were analyzed by a consortium of 2 echocardiography core laboratories. RESULTS: The percentage of moderate or severe aortic regurgitation (AR) was low and not statistically different between the TAVR and SAVR groups at 30 days (0.8% versus 0.2%; P=0.38). Mild AR was more frequent after TAVR than SAVR at 30 days (28.8% versus 4.2%; P<0.001). At 1 year, mean transvalvular gradient (13.7±5.6 versus 11.6±5.0 mm Hg; P=0.12) and aortic valve area (1.72±0.37 versus 1.76±0.42 cm2; P=0.12) were similar in TAVR and SAVR. The percentage of severe prosthesis-patient mismatch at 30 days was low and similar between TAVR and SAVR (4.6 versus 6.3%; P=0.30). Valvulo-arterial impedance (Zva), which reflects total left ventricular hemodynamic burden, was lower with TAVR than SAVR at 1 year (3.7±0.8 versus 3.9±0.9 mm Hg/mL/m2; P<0.001). Tricuspid annulus plane systolic excursion decreased and the percentage of moderate or severe tricuspid regurgitation increased from baseline to 1 year in SAVR but remained unchanged in TAVR. Irrespective of treatment arm, high Zva and low tricuspid annulus plane systolic excursion, but not moderate to severe AR or severe prosthesis-patient mismatch, were associated with increased risk of the composite end point of mortality, stroke, and rehospitalization at 1 year. CONCLUSIONS: In patients with severe aortic stenosis and low surgical risk, TAVR with the SAPIEN 3 valve was associated with similar percentage of moderate or severe AR compared with SAVR but higher percentage of mild AR. Transprosthetic gradients, valve areas, percentage of severe prosthesis-patient mismatch, and left ventricular mass regression were similar in TAVR and SAVR. SAVR was associated with significant deterioration of right ventricular systolic function and greater tricuspid regurgitation, which persisted at 1 year. High Zva and low tricuspid annulus plane systolic excursion were associated with worse outcome at 1 year whereas AR and severe prosthesis-patient mismatch were not. Registration: URL: https://www.clinicaltrials.gov; Unique identifier: NCT02675114.


Assuntos
Estenose da Valva Aórtica/cirurgia , Valva Aórtica/cirurgia , Ecocardiografia , Implante de Prótese de Valva Cardíaca , Substituição da Valva Aórtica Transcateter , Idoso , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/fisiopatologia , Insuficiência da Valva Aórtica/diagnóstico por imagem , Insuficiência da Valva Aórtica/etiologia , Insuficiência da Valva Aórtica/fisiopatologia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/mortalidade , Estenose da Valva Aórtica/fisiopatologia , Feminino , Próteses Valvulares Cardíacas , Implante de Prótese de Valva Cardíaca/efeitos adversos , Implante de Prótese de Valva Cardíaca/instrumentação , Implante de Prótese de Valva Cardíaca/mortalidade , Hemodinâmica , Humanos , Masculino , América do Norte , Valor Preditivo dos Testes , Desenho de Prótese , Falha de Prótese , Medição de Risco , Fatores de Risco , Índice de Gravidade de Doença , Fatores de Tempo , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/instrumentação , Substituição da Valva Aórtica Transcateter/mortalidade , Resultado do Tratamento
7.
Clin Chem ; 67(12): 1618-1627, 2021 11 26.
Artigo em Inglês | MEDLINE | ID: mdl-34718463

RESUMO

BACKGROUND: Chromogranin A (CgA) is a 48 kDa protein that serves as a diagnostically sensitive, but nonspecific, serum biomarker for neuroendocrine tumors. Immunoassays for CgA are not standardized and have a narrow dynamic range, which requires dilution of concentrated specimens. We developed and validated an antibody-free, liquid chromatography-tandem mass spectrometry (LC-MS/MS)-based method for CgA without these limitations. METHODS: CgA was extracted from serum using a mixed-mode anion exchange solid-phase extraction plate, digested with trypsin, and analyzed by LC-MS/MS using well-characterized CgA calibration standards. After validation, the mass spectrometry method was compared with the CISBIO immunoassay using 200 serum specimens previously submitted for CgA analysis. Specimens with discordant results were reanalyzed by high-resolution mass spectrometry- (HRMS) -based methods to assess the contribution of truncated and post-translationally modified forms of CgA. RESULTS: The assay had a linear range of 50 to 50 000 ng/mL, recoveries between 89% and 115%, and intra- and interassay imprecision <10%. LC-MS/MS assay results showed a Pearson's correlation of r = 0.953 with the CISBIO immunoassay, with CgA values being a mean 2- to 4-fold higher. Concordance for CgA between the 2 assays was 80.9% (95% CI 72.8%-89.2%), showing substantial agreement. Truncation and posttranslational modification, including 2 phosphorylation sites that had not been previously observed or predicted to our knowledge, did not appear to contribute directly to discordance between the 2 assays. CONCLUSION: Quantification of CgA by LC-MS/MS provides an analytically sensitive and reproducible alternative to commercially available immunoassays.


Assuntos
Cromogranina A , Tumores Neuroendócrinos , Espectrometria de Massas em Tandem , Cromatografia Líquida , Cromogranina A/sangue , Humanos , Imunoensaio , Tumores Neuroendócrinos/diagnóstico , Reprodutibilidade dos Testes , Espectrometria de Massas em Tandem/métodos
8.
J Card Surg ; 36(2): 493-500, 2021 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-33283359

RESUMO

BACKGROUND: Transcatheter valve-in-valve implantation (TViV) and minimally invasive reoperative aortic valve replacement (MIrAVR) have rapidly increased as alternatives to conventional reoperative surgical AVR. This study reports a single-center experience of patients undergoing TViV and MIrAVR after bioprosthetic valve failure. METHODS: In this retrospective review between March 2009 and October 2018, 68 patients without reoperative full sternotomies, concomitant procedures, active endocarditis, and prior homografts or coronary artery bypass grafting underwent isolated AVR for degenerated aortic bioprostheses. Society of Thoracic Surgeons (STS) risk scores and age are reported as median (interquartile range [IQR]) and length of stay is reported as mean (standard deviation [SD]) due to their characteristics of the distribution. RESULTS: Forty-one (60.3%) patients underwent TViV, and 27 (39.7%) patients underwent MIrAVR. Median [IQR] STS risk scores were 5.7 [4.0-7.8] and 2.0 [1.5-3.4] for TViV and MIrAVR, respectively (p ≤ .001). The median [IQR] age for TViV patients was higher (78 [71-84] vs. 66 [53-72] years, p ≤ 0.001). More permanent pacemakers were implanted (22.2% vs. 9.8%) following MIrAVR. The MIrAVR group had a higher rate of atrial fibrillation (18.5% vs. 9.8%, p = .466). Average (SD) length of stay was less in TViV (5.3 days, SD: 3.4 vs. 8.6 days, SD: 7.4, p = .001). Survival at 1 year was not significantly different for TViV and MIrAVR (94.9% [95% confidence interval [CI]: 81.0%, 98.7%] and 86.9% [95% CI: 64.0%, 95.7%], respectively [p = .969]). CONCLUSIONS: Despite being at higher-risk, patients undergoing TViV had reduced rates of permanent pacemaker implantations and atrial fibrillation, and a shorter hospital stay as compared to MIrAVR. Survival at 1-year was similar between the two groups.


Assuntos
Bioprótese , Implante de Prótese de Valva Cardíaca , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Valva Aórtica/cirurgia , Humanos , Estudos Retrospectivos , Fatores de Risco , Resultado do Tratamento
9.
Clin Chem ; 65(12): 1572-1580, 2019 12.
Artigo em Inglês | MEDLINE | ID: mdl-31628138

RESUMO

BACKGROUND: The ratio of ß-amyloid 1-42 (Aß42) to Aß40 in cerebrospinal fluid (CSF) may be useful for evaluating Alzheimer disease (AD), but quantification is limited by factors including preanalytical analyte loss. We developed an LC-MS/MS assay that limits analyte loss. Here we describe the analytical characteristics of the assay and its performance in differentiating patients with AD from non-AD dementia and healthy controls. METHODS: To measure Aß42/Aß40, we used unique proteolytically derived C-terminal peptides as surrogate markers of Aß40 and Aß42, which were analyzed and quantified by LC-MS/MS. The assay was analytically validated and applied to specimens from individuals with clinically diagnosed AD (n = 102), mild cognitive impairment (n = 37), and non-AD dementias (n = 22), as well as from healthy controls (n = 130). Aß42/Aß40 values were compared with APOE genotype inferred from phenotype, also measured by LC-MS/MS. RESULTS: The assay had a reportable range of 100 to 25000 pg/mL, a limit of quantification of 100 pg/mL, recoveries between 93% and 111%, and intraassay and interassay CV <15% for both peptides. An Aß42/Aß40 ratio cutoff of <0.16 had a clinical sensitivity of 78% for distinguishing patients with AD from non-AD dementia (clinical specificity, 91%) and from healthy controls (clinical specificity, 81%). The Aß42/Aß40 ratio decreased significantly (P < 0.001) with increasing dose of APOE4 alleles. CONCLUSIONS: This assay can be used to determine Aß42/Aß40 ratios, which correlate with the presence of AD.


Assuntos
Peptídeos beta-Amiloides/análise , Fragmentos de Peptídeos/análise , Espectrometria de Massas em Tandem/métodos , Idoso , Doença de Alzheimer/diagnóstico , Doença de Alzheimer/metabolismo , Peptídeos beta-Amiloides/líquido cefalorraquidiano , Biomarcadores/líquido cefalorraquidiano , Cromatografia Líquida/métodos , Disfunção Cognitiva/diagnóstico , Disfunção Cognitiva/metabolismo , Demência/diagnóstico , Demência/metabolismo , Feminino , Ensaios de Triagem em Larga Escala/métodos , Humanos , Masculino , Pessoa de Meia-Idade , Fragmentos de Peptídeos/líquido cefalorraquidiano , Sensibilidade e Especificidade , Proteínas tau/líquido cefalorraquidiano
11.
J Strength Cond Res ; 32(9): 2425-2434, 2018 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-29985225

RESUMO

Fragala, MS, Goldman, SM, Goldman, MM, Bi, C, Colletti, JD, Arent, SM, Walker, AJ, and Clarke, NJ. Measurement of cortisol and testosterone in athletes: Accuracy of LC-MS/MS assays for cortisol and testosterone measurement in whole-blood microspecimens. J Strength Cond Res 32(9): 2425-2434, 2018-Biomarker monitoring provides insight into athletes' training tolerance but is limited by the need for office-based specimen collection. To facilitate self-collection during training, we developed liquid chromatography-tandem mass spectrometry-based tests that measure circulating total cortisol and testosterone using a finger stick volumetric absorptive microsampler. Here, we describe the analytical validation of these tests. Forty-six Division I athletes (18-22 years, 30 women, 16 men) provided a 20-µL finger stick microspecimen and a 5-ml venous blood specimen from the forearm; the venous blood sample was analyzed using both normal volume serum analysis and analysis of dried whole blood (from the microsampler). Liquid chromatography-tandem mass spectrometry on standard serum specimens obtained by venipuncture yielded total cortisol levels of 26.2 ± 11.6 µg·dl (women and men), and total testosterone levels of 37 ± 17 ng·dl in women and 564 ± 171 ng·dl in men. Analytical measurement ranges of the microspecimen assay were 0.3-440 µg·dl (CV <9%) for cortisol and 15 to 20,000 ng·dl (CV <9%) for testosterone. Deming regression and Pearson correlation indicated good test accuracy for the microspecimen tests compared with venipuncture tests for cortisol (y = 0.98x + 1.34, 95% CI of slope = 0.83-1.14; r = 0.92, p < 0.0001) and testosterone (y = 1.06x - 0.01, 95% CI of slope = 0.99-1.14; r = 0.99, p < 0.0001). Similarly, high agreement was observed between finger stick and venous microspecimens for cortisol (y = 1.00x + 0.65, 95% CI of slope = 0.9-1.11; r = 0.96, p < 0.001) and testosterone (y = 0.97x + 2.75, 95% CI of slope = 0.9-1.03; r = 0.99, p < 0.001). These findings suggest the viability of finger stick collection whole-blood microspecimens for assessment of total cortisol and testosterone in athletes.


Assuntos
Cromatografia Líquida/métodos , Hidrocortisona/sangue , Espectrometria de Massas em Tandem/métodos , Testosterona/sangue , Adolescente , Atletas , Cromatografia Líquida/normas , Feminino , Humanos , Masculino , Espectrometria de Massas em Tandem/normas , Adulto Jovem
12.
Cytotherapy ; 18(6): 729-39, 2016 06.
Artigo em Inglês | MEDLINE | ID: mdl-27173749

RESUMO

BACKGROUND AIMS: The use of bone marrow-derived mesenchymal stromal cells (MSCs) in cell-based therapies is currently being developed for a number of diseases. Thus far, the clinical results have been inconclusive and variable, in part because of the variety of cell isolation procedures and culture conditions used in each study. A new isolation technique that streamlines the method of concentration and demands less time and attention could provide clinical and economic advantages compared with current methodologies. In this study, we evaluated the concentrating capability of an integrated centrifuge-based technology compared with standard Ficoll isolation. METHODS: MSCs were concentrated from bone marrow aspirate using the new device and the Ficoll method. The isolation capabilities of the device and the growth characteristics, secretome production, and differentiation capacity of the derived cells were determined. RESULTS: The new MSC isolation device concentrated the bone marrow in 90 seconds and resulted in a mononuclear cell yield 10-fold higher and with a twofold increase in cell retention compared with Ficoll. The cells isolated using the device were shown to exhibit similar morphology and functional activity as assessed by growth curves and secretome production compared to the Ficoll-isolated cells. The surface marker and trilineage differentiation profile of the device-isolated cells was consistent with the known profile of MSCs. DISCUSSION: The faster time to isolation and greater cell yield of the integrated centrifuge-based technology may make this an improved approach for MSC isolation from bone marrow aspirates.


Assuntos
Células da Medula Óssea/citologia , Separação Celular/métodos , Centrifugação/métodos , Células-Tronco Mesenquimais/citologia , Medula Óssea , Diferenciação Celular/fisiologia , Proliferação de Células , Terapia Baseada em Transplante de Células e Tecidos/métodos , Ficoll , Humanos , Osteoblastos/citologia
13.
Asian Cardiovasc Thorac Ann ; 32(4): 234-243, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38343086

RESUMO

BACKGROUND: Research comparing the effectiveness of central aortic cannulation to axillary artery cannulation in repairing acute type A aortic dissection is limited and controversial. This meta-analysis aimed to compare early outcomes of central aortic cannulation versus axillary artery cannulation for surgery for acute aortic dissection type A. METHODS: A comprehensive systematic search was conducted across PubMed/MEDLINE, Scopus, and the Cochrane Central Register of Controlled Trials up to September 1, 2023. The primary endpoints were operative mortality and incidence of postoperative stroke. Secondary endpoints encompassed cardiopulmonary bypass time, myocardial ischemic time, hypothermic circulatory arrest time, postoperative temporary neurological dysfunction, combination of stroke and temporary neurological dysfunction, as well as the need for reexploration for bleeding, renal replacement therapy, and tracheotomy. A random-effect model was utilized to calculate the pooled effect size. RESULTS: Eleven studies met our eligibility criteria, enrolling a total of 7204 patients (2760 underwent aortic cannulation and 4444 underwent axillary cannulation). The operative mortality and incidence of postoperative stroke did not show statistical differences between the two groups, with a pooled odds ratio of 1.07 (95% confidence interval: 0.73-1.55) and 1.17 (0.95-1.42), respectively. Similarly, none of the secondary endpoints exhibited significant statistical differences between the two groups. CONCLUSIONS: Aortic cannulation can be a viable alternative to axillary artery cannulation for repair of acute aortic dissection type A, as both approaches present similar early clinical outcomes.


Assuntos
Aneurisma Aórtico , Dissecção Aórtica , Artéria Axilar , Cateterismo Periférico , Adulto , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Doença Aguda , Aorta/cirurgia , Aneurisma Aórtico/cirurgia , Aneurisma Aórtico/mortalidade , Aneurisma Aórtico/diagnóstico por imagem , Dissecção Aórtica/cirurgia , Dissecção Aórtica/mortalidade , Dissecção Aórtica/diagnóstico por imagem , Artéria Axilar/cirurgia , Implante de Prótese Vascular/efeitos adversos , Implante de Prótese Vascular/mortalidade , Cateterismo Periférico/efeitos adversos , Cateterismo Periférico/mortalidade , Medição de Risco , Fatores de Risco , Acidente Vascular Cerebral/etiologia , Acidente Vascular Cerebral/mortalidade , Fatores de Tempo , Resultado do Tratamento
14.
J Investig Med ; 72(5): 465-474, 2024 06.
Artigo em Inglês | MEDLINE | ID: mdl-38548482

RESUMO

Early detection of Alzheimer's disease (AD) represents an unmet clinical need. Beta-amyloid (Aß) plays an important role in AD pathology, and the Aß42/40 peptide ratio is a good indicator for amyloid deposition. In addition, variants of the apolipoprotein E (APOE) gene are associated with variable AD risk. Here, we describe the development and validation of high-throughput liquid chromatography-tandem mass spectrometry (LC-MS/MS) assays for plasma Aß40 and Aß42 quantitation, as well as apolipoprotein E (ApoE) proteotype determination as a surrogate for APOE genotype. Aß40 and Aß42 were simultaneously immunoprecipitated from plasma, proteolytically digested, and quantitated by LC-MS/MS. ApoE proteotype status was qualitatively assessed by targeting tryptic peptides from the ApoE2, ApoE3, and ApoE4 proteoforms. Both assays were validated according to the Clinical and Laboratory Standards Institute (CLSI) guidelines. Within-run precision was 1.8%-4.2% (Aß40), 1.9%-7.2% (Aß42), and 2.6%-8.3% (Aß42/40 ratio). Between-run precision was 3.5%-5.9% (Aß40), 3.8%-8.0% (Aß42), and 3.3%-8.7% (Aß42/40 ratio). Both Aß40 and Aß42 were linear from 10 to 2500 pg/mL. Identified ApoE proteotypes had 100% concordance with APOE genotypes. We have developed a precise, accurate, and sensitive high-throughput LC-MS/MS assay for plasma Aß40, Aß42, and proteoforms of ApoE.


Assuntos
Doença de Alzheimer , Peptídeos beta-Amiloides , Apolipoproteínas E , Espectrometria de Massas em Tandem , Peptídeos beta-Amiloides/sangue , Humanos , Apolipoproteínas E/genética , Apolipoproteínas E/sangue , Doença de Alzheimer/sangue , Doença de Alzheimer/diagnóstico , Doença de Alzheimer/genética , Cromatografia Líquida , Medição de Risco , Reprodutibilidade dos Testes , Feminino , Masculino , Fragmentos de Peptídeos/sangue , Idoso , Espectrometria de Massa com Cromatografia Líquida
15.
Future Cardiol ; : 1-12, 2024 Jul 04.
Artigo em Inglês | MEDLINE | ID: mdl-38963122

RESUMO

Aim: To evaluate the effects of double (axillary and femoral) vs. single (axillary) cannulation on early outcomes of acute type A aortic dissection (ATAAD). Materials & methods: Meta-analysis using PubMed/MEDLINE, Scopus, and Cochrane databases through August 23, 2023. Focused on operative mortality, postoperative stroke, re-exploration for bleeding, spinal cord injury, and renal replacement therapy. Results: Among 5 propensity score-matched studies with 2127 patients, double cannulation showed comparable mortality and higher rates of postoperative stroke (pooled odds ratio: 1.69, 95% confidence interval: 1.19-2.39) and need for renal replacement therapy (pooled odds ratio: 1.35, 95% confidence interval: 1.13-1.60) compared with single cannulation. Conclusion: Double arterial cannulation in ATAAD surgery is associated with increased postoperative stroke and renal replacement therapy than single cannulation.


What is this summary about? We studied the optimal way to maintain blood flow during surgery for acute aortic dissection. We focused on comparing the use of one tube placement site in the axillary artery with two sites, both in the axillary and femoral arteries, in five previous studies.What were the results? Using two sites was associated with a higher risk of stroke and need for dialysis after surgery than using only one site.What do the results mean? Adding a tube in the femoral artery for blood flow may increase the risk of complications. It appears that placing the tube only in the axillary artery may be a safer choice for appropriately selected patients having this surgery.

16.
Front Neurol ; 15: 1364658, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38595851

RESUMO

Introduction: Plasma Aß42/40 ratio can help predict amyloid PET status, but its clinical utility in Alzheimer's disease (AD) assessment is unclear. Methods: Aß42/40 ratio was measured by LC-MS/MS for 250 specimens with associated amyloid PET imaging, diagnosis, and demographic data, and for 6,192 consecutive clinical specimens submitted for Aß42/40 testing. Results: High diagnostic sensitivity and negative predictive value (NPV) for Aß-PET positivity were observed, consistent with the clinical performance of other plasma LC-MS/MS assays, but with greater separation between Aß42/40 values for individuals with positive vs. negative Aß-PET results. Assuming a moderate prevalence of Aß-PET positivity, a cutpoint was identified with 99% NPV, which could help predict that AD is likely not the cause of patients' cognitive impairment and help reduce PET evaluation by about 40%. Conclusion: High-throughput plasma Aß42/40 LC-MS/MS assays can help identify patients with low likelihood of AD pathology, which can reduce PET evaluations, allowing for cost savings.

17.
Artigo em Inglês | MEDLINE | ID: mdl-38719630

RESUMO

BACKGROUND/PURPOSE: To evaluate the impact of coronary artery disease (CAD), percutaneous coronary intervention (PCI), and coronary lesion complexity on outcomes of transcatheter aortic valve replacement (TAVR) for aortic stenosis. METHODS/MATERIALS: This retrospective study included 1042 patients divided into two groups by the presence or absence of CAD (SYNTAX score 0, no history of revascularization). Propensity score matching was used to compare the two groups. The effect of PCI, SYNTAX score, and residual SYNTAX score was also analyzed. RESULTS: The median age of the cohort was 82 years, and 641 patients had CAD. After propensity score matching, 346 pairs were analyzed. During 5 years of follow-up (median: 25, range 0-72 months), the rate of coronary intervention was significantly higher in CAD patients (p = 0.018). However, all-cause mortality, composite of all-cause mortality, stroke, and coronary intervention, and overt bleeding defined by VARC-3 were comparable. After stratification, in patients with creatinine ≥1.5 mg/dl, CAD was associated with a worse composite outcome (p = 0.016). Neither PCI nor SYNTAX score was associated with all-cause mortality in CAD patients. Similarly, residual SYNTAX score showed no association with mortality in patients undergoing PCI (all p values >0.7). PCI did not reach a significant difference in overt bleeding in CAD patients (adjusted p = 0.06). CONCLUSIONS: Despite a higher incidence of coronary interventions, major clinical outcomes were similar between patients with and without CAD after TAVR. In patients with chronic kidney disease, CAD may be associated with an adverse composite outcome. Neither PCI nor SYNTAX/residual SYNTAX score influenced all-cause mortality.

18.
J Invasive Cardiol ; 36(5)2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38422528

RESUMO

OBJECTIVES: To assess the impact of concomitant mitral stenosis (MS) on early and late outcomes of transcatheter aortic valve replacement (TAVR) for aortic stenosis. METHODS: This study involved 952 patients undergoing TAVR for severe tricuspid aortic stenosis. The patients were classified into 3 groups: without MS, with progressive MS, and severe MS (mitral valve area ≤ 1.5 cm2). Clinical outcomes between these groups were compared. RESULTS: The median age of the overall cohort was 82 years, and patients in the progressive (n = 49) and severe (n = 24) MS groups were more likely to be female than those in the no-MS group (n = 879). Periprocedural mortality rate was lowest in the no-MS group (1.8%) compared with the progressive (4.1%) and severe (4.2%) MS groups, which were not significantly different (P = .20). During 5 years of follow-up (median: 27, range: 0-72 months), there was no significant difference in all-cause mortality (log-rank P = .99), a composite of all-cause mortality or rehospitalization for heart failure (log-rank P = .84), or cardiovascular death (log-rank P = .57) between groups. Although crude analysis showed a significant difference in rehospitalization for heart failure in the severe MS group compared with the no-MS group (P = .049), the difference was not significant in the multivariate analysis (adjusted hazard ratio: 1.36 [95% CI, 0.66-2.80], P = .41). CONCLUSIONS: TAVR can be safely performed in patients with severe tricuspid aortic stenosis and concomitant MS, with early and mid-term outcomes comparable to those in patients without MS.


Assuntos
Estenose da Valva Aórtica , Estenose da Valva Mitral , Substituição da Valva Aórtica Transcateter , Humanos , Feminino , Masculino , Estenose da Valva Mitral/cirurgia , Estenose da Valva Mitral/diagnóstico , Estenose da Valva Mitral/complicações , Substituição da Valva Aórtica Transcateter/métodos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Estenose da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/complicações , Estenose da Valva Aórtica/diagnóstico , Idoso de 80 Anos ou mais , Estudos Retrospectivos , Seguimentos , Índice de Gravidade de Doença , Resultado do Tratamento , Idoso , Taxa de Sobrevida/tendências , Fatores de Tempo , Fatores de Risco , Complicações Pós-Operatórias/epidemiologia
19.
Am J Cardiol ; 221: 9-18, 2024 Jun 15.
Artigo em Inglês | MEDLINE | ID: mdl-38636627

RESUMO

Patients with small aortic annuli (SAA) pose a challenge in patients undergoing aortic valve replacement because of the potential for prosthesis-patient mismatch (PPM). This study aimed to compare the clinical and hemodynamic outcomes of self-expandable valve (SEV) versus balloon-expandable valve (BEV) transcatheter aortic valve implantation (TAVI) in patients with severe aortic stenosis and SAA. All patients who underwent TAVI for severe native aortic stenosis with a SAA between January 2018 and December 2022 were retrospectively included in the study from a single center. Propensity score matching was performed to balance the baseline characteristics. Bioprosthesis valve dysfunction was based on modified Valve Academic Research Consortium 3 criteria. A total of 1,170 TAVI procedures were performed between 2018 and 2022. After applying the exclusion criteria, 332 patients reported a SAA at computed tomography scan, and the matching created 109 balanced pairs. Echocardiographic data at discharge showed higher mean transvalvular gradients (p <0.001), higher grades of mitral regurgitation (p = 0.029), and lower ejection fraction (p <0.043) in BEVs than SEVs. At follow-up, significant differences favoring the SEV group regarding bioprosthesis valve dysfunction were observed (p = 0.002), especially in terms of severe PPM (p = 0.046) and at least moderate structural valve deterioration (p = 0.040). In conclusion, TAVI in patients with SAA using a BEV was associated with lower valve areas, higher mean pressure gradients, and PPM (including severe) than a SEV. Short- and midterm all-cause and cardiac-related mortality did not differ between the 2 groups. Future randomized studies with extended follow-ups are warranted to validate these outcomes.


Assuntos
Estenose da Valva Aórtica , Valva Aórtica , Bioprótese , Próteses Valvulares Cardíacas , Hemodinâmica , Pontuação de Propensão , Desenho de Prótese , Substituição da Valva Aórtica Transcateter , Humanos , Substituição da Valva Aórtica Transcateter/métodos , Masculino , Feminino , Estenose da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/fisiopatologia , Hemodinâmica/fisiologia , Estudos Retrospectivos , Idoso de 80 Anos ou mais , Valva Aórtica/cirurgia , Idoso , Ecocardiografia
20.
Coron Artery Dis ; 2024 May 14.
Artigo em Inglês | MEDLINE | ID: mdl-38739467

RESUMO

OBJECTIVE: To investigate the impact of prior coronary artery bypass grafting (CABG) and coronary lesion complexity on transcatheter aortic valve replacement (TAVR) outcomes for aortic stenosis. METHODS: Clinical outcomes of TAVR were retrospectively compared between patients with and without prior CABG, and between patients with prior CABG and without coronary artery disease (CAD). The impact of the CABG SYNTAX score was also evaluated in patients with prior CABG. RESULTS: The study included 1042 patients with a median age and follow-up of 82 years and 25 (range: 0-72) months, respectively. Of these, 175 patients had a history of CABG, while 401 were free of CAD. Patients with prior CABG were more likely to be male and had higher rates of diabetes, peripheral artery disease and atrial fibrillation compared with patients without prior CABG. After 2 : 1 propensity score matching, all-cause mortality (P = 0.17) and the composite of all-cause mortality, stroke and coronary intervention (P = 0.16) were similar between patients with (n = 166) and without (n = 304) prior CABG. A 1 : 1 propensity score-matched analysis, however, showed lower rates of all-cause mortality (P = 0.04) and the composite outcome (P = 0.04) in patients with prior CABG (n = 134) compared with patients without CAD (n = 134). The median CABG SYNTAX score was 16 (interquartile range: 9.0-23), which was not associated with better/worse clinical outcomes in patients with prior CABG. CONCLUSION: Prior CABG may positively affect mid-term TAVR outcomes for aortic stenosis compared with no CAD when adjusted for other comorbidities. The CABG SYNTAX score did not influence the prognosis after TAVR.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA