Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 15 de 15
Filtrar
1.
J Arthroplasty ; 37(4): 734-741, 2022 04.
Artigo em Inglês | MEDLINE | ID: mdl-34968648

RESUMO

BACKGROUND: Squatting is an important function for many daily activities, but has not been well documented after total hip arthroplasty (THA). This study investigated the participation rate of squatting and in vivo kinematics during squatting. METHODS: A survey questionnaire about squatting was mailed to patients who underwent primary THA and 328 patients returned acceptable responses. Additionally, 32 hips were evaluated for dynamic 3-dimensional kinematics of squatting using density-based image-matching techniques. Multivariate analyses were applied to determine which factors were associated with anterior liner-to-neck distance at maximum hip flexion. RESULTS: Patients who could easily squat significantly increased this ability postoperatively (23.5% vs 46%, P < .01). In 29.5% of the patients there was still no ability to squat after THA; the main reason was anxiety of dislocation (34.2%). Kinematic analysis revealed that maximum hip flexion averaged 80.7° ± 12.3° with 12.8° ± 10.7° of posterior pelvic tilt and 9.7 ± 3.0 mm of anterior liner-to-neck distance. Neither liner-to-neck, bone-to-bone, nor bone-to-implant contact was observed in any of the hips. Larger hip flexion and smaller cup anteversion were negatively associated with the anterior liner-to-neck distance at maximum hip flexion (P < .05). CONCLUSION: Postoperatively, approximately 70% of patients squatted easily or with support. Anxiety of dislocation made patients avoid squatting after THA. In vivo squatting kinematics suggest no danger of impingement or subsequent dislocation, but excessively large hip flexion and small cup anteversion remain as risks.


Assuntos
Artroplastia de Quadril , Prótese de Quadril , Luxações Articulares , Artroplastia de Quadril/métodos , Fenômenos Biomecânicos , Articulação do Quadril/cirurgia , Humanos , Luxações Articulares/cirurgia , Medidas de Resultados Relatados pelo Paciente , Amplitude de Movimento Articular
2.
J Orthop Sci ; 27(3): 665-671, 2022 May.
Artigo em Inglês | MEDLINE | ID: mdl-33933328

RESUMO

BACKGROUND: Mid-flexion instability is the one of the reasons for patient dissatisfaction after total knee arthroplasty (TKA). The purposes of this study were to evaluate in vivo knee kinematics and clinical outcomes using a novel TKA design with a gradual femoral radius component and s-curve post-cam, which are intended to prevent the instability initiated by sudden reductions in the femoral radius observed with conventional components. METHODS: We used radiographic-based, image-matching techniques to analyze femorotibial anteroposterior translation, axial rotation, and anterior/posterior cam-post contact during two dynamic movements, squatting and stair climbing, in 20 knees that had undergone posterior-stabilized fixed-bearing TKA with an improved sagittal profiles of the femoral component and post-cam mechanism. We also evaluated patient-reported outcomes assessed by the 2011 Knee Society Score (KSS 2011). RESULTS: Squatting and stair climbing produced a similar trend in anteroposterior translation and a relatively small standard deviation at mid-flexion. Although the rotation angles varied widely during squatting and stair climbing, the femoral component was consistently externally rotated. Anterior/posterior cam-post contact during squatting and stair climbing were observed in 0/17 knees and 0/0 knees, respectively. The "Symptoms", "Satisfaction", and "Functional activities" subscales of the KSS 2011 were significantly (P < 0.05) improved postoperatively compared to preoperatively ("Symptoms", 10 to 21; "Satisfaction", 15 to 26; "Functional activities", 25 to 71). CONCLUSION: A gradual femoral radius component with an s-curve post-cam provided stable kinematics and favorable clinical results during squatting and stair climbing at 1 year after surgery.


Assuntos
Artroplastia do Joelho , Prótese do Joelho , Artroplastia do Joelho/métodos , Fenômenos Biomecânicos , Humanos , Articulação do Joelho/diagnóstico por imagem , Articulação do Joelho/cirurgia , Rádio (Anatomia)/cirurgia , Amplitude de Movimento Articular
3.
BMC Musculoskelet Disord ; 22(1): 772, 2021 Sep 12.
Artigo em Inglês | MEDLINE | ID: mdl-34511113

RESUMO

BACKGROUND: No studies have directly evaluated kinematic changes during squatting before and after bicruciate-stabilized total knee arthroplasty (BCS-TKA) with the dual cam-post mechanism and asymmetric surfaces. This study investigated the effect of BCS-TKA on changes to pre- and postoperative skeletal knee kinematics, to identify factors associated with postoperative skeletal kinematic parameters. METHODS: Seventeen knees in 17 patients were prospectively recruited before primary TKA for advanced medial knee osteoarthritis. Subjects underwent BCS-TKA and were evaluated more than 1 year postoperatively. In vivo dynamic skeletal knee kinematics were evaluated using periodic radiographic images collected during squatting to quantify the tibiofemoral functional extension/flexion angle, anteroposterior (AP) translation, and axial rotation angle using image-matching techniques. Rotational alignments of femoral and tibial components were measured postoperatively using computed tomography images. RESULTS: The pre- and postoperative tibiofemoral functional extension/flexion angles during squatting were 12.2° ± 6.7°/100.1° ± 16.8° and 9.6° ± 8.6°/109.4° ± 16.8°, respectively, with a significant difference in flexion angle (p < .05). Total AP translation was significantly larger postoperatively than preoperatively (10.8 mm ± 3.7 mm vs. 14.4 mm ± 4.2 mm, respectively; p < .05). The pre- and postoperative total rotation angles were 6.6° ± 3.0° and 6.4° ± 3.7°, respectively, indicating no significant difference. The pre- and postoperative tibiofemoral functional flexion angles were significantly associated with each other (p = .0434, r = .49). The postoperative total rotation angle was significantly smaller when the total component rotational mismatch angle between the femoral and tibial components was above 5° vs. below 5° (4.6° ± 2.7° vs. 8.3° ± 3.9°, respectively; p < .05). CONCLUSIONS: BCS-TKA significantly increased the tibiofemoral functional flexion angles, with larger AP translation postoperatively. Both preoperative skeletal kinematics and surgical techniques affected the skeletal kinematics of the replaced knee. A total component rotational mismatch angle greater than 5° significantly decreased postoperative total knee rotation during squatting.


Assuntos
Artroplastia do Joelho , Prótese do Joelho , Osteoartrite do Joelho , Fenômenos Biomecânicos , Humanos , Articulação do Joelho/diagnóstico por imagem , Articulação do Joelho/cirurgia , Osteoartrite do Joelho/diagnóstico por imagem , Osteoartrite do Joelho/cirurgia , Amplitude de Movimento Articular , Rotação , Tíbia/diagnóstico por imagem , Tíbia/cirurgia
4.
J Orthop Sci ; 25(3): 452-459, 2020 May.
Artigo em Inglês | MEDLINE | ID: mdl-31178276

RESUMO

BACKGROUND: There is an interest in quantifying dynamic hip kinematics before and after total hip arthroplasty (THA) during chair-rising: one of daily life activities. METHODS: The study consisted of 21 patients who underwent unilateral total hip arthroplasty for symptomatic osteoarthritis. We obtained continuous radiographs using a flat-panel X-ray detector while the participants rose from chair. We assessed the pre and postoperative hip joint's movements using three-dimensional-to-two-dimensional model-to-image registration techniques. We also measured minimum liner-to-neck distances at maximum hip flexion and extension as anterior and posterior liner-to-neck distances, respectively. Multivariate analyses were applied to determine which factors were associated with liner-to-neck distances. RESULTS: The cup inclination, cup anteversion, and stem anteversion averaged 37.4°, 23.1°, and 30.1°, respectively. Significantly larger maximum hip flexion angle (72°) was found during chair-rising after THA compared to that before THA (63°, P < 0.01). The anterior pelvic tilt at the maximum hip flexion after THA (3° of anterior tilt) was significantly (P < 0.05) anterior compared to that before THA (1° of posterior tilt). The anterior and posterior liner-to-neck distances averaged 12.3 mm and 8.1 mm, respectively, with a significant difference (P < 0.01). No liner-to-neck contact was found in any hips. In multivariate analysis, the hip flexion angle, cup inclination, stem anteversion and head diameter were significantly associated with the anterior liner-to-neck distance (P < 0.05), the hip extension angle, cup anteversion, neck length and with or without elevated rim were significantly associated with the posterior liner-to-neck distance (P < 0.05, 0.01, 0.05, 0.01, respectively). CONCLUSION: This study indicates that well-positioned THA provide increased range of hip flexion with sufficient anterior liner-to-neck clearance during chair-rising. Dynamic hip kinematics, component position, and hardware variables significantly influenced on the liner-to-neck clearance under weight-bearing conditions.


Assuntos
Artroplastia de Quadril , Prótese de Quadril , Movimento , Suporte de Carga , Atividades Cotidianas , Idoso , Idoso de 80 Anos ou mais , Fenômenos Biomecânicos , Desenho Assistido por Computador , Avaliação da Deficiência , Feminino , Humanos , Imageamento Tridimensional , Estudos Longitudinais , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Amplitude de Movimento Articular
5.
Clin Biomech (Bristol, Avon) ; 91: 105537, 2022 01.
Artigo em Inglês | MEDLINE | ID: mdl-34847472

RESUMO

Background After total hip arthroplasty, dislocation can occur when a patient unexpectedly assumes internal/external limb positions, even during chair-rising, which is a frequently activity of daily life. Therefore, determining the target cup position to avoid impingement in unexpected limb positions using in vivo data of daily life activities is critical. Methods A computer simulation was performed on 21 total hip arthroplasty patients using patient-specific component placements and hip kinematics obtained during chair-rising analysis using image-matching techniques. The liner-to-neck distance and impingement were evaluated by simulating the change in internal/external rotation angle at maximum hip flexion/extension from 0 to 90°. The cutoff values of cup anteversion and combined anteversion at 60° of internal/external rotation were determined. Findings The anterior/posterior liner-to-neck distances were negatively correlated with internal/external rotation angles (r = -0.82 and -0.78, respectively) and decreased by 1.7 and 1.8 mm for every 15° increase, respectively. Three cases (14%) of anterior/posterior impingement were observed at 60° of internal/external rotation angle, respectively. The cutoff values for cup anteversion and combined anteversion to avoid impingement at 60° of internal/external rotation angle were 12°-25°/38°-62°, respectively. The stem anteversion, adjustable by cup anteversion to meet both the target cup anteversion and combined anteversion, was 13°-50°. Interpretation Simulated unintentional internal or external hip rotation, even during chair-rising, caused impingement and posed a dislocation risk. If the stem anteversion is excessively small or large in meeting the target combined anteversion, adjustments to stem anteversion could be recommended in addition to adjustments in cup anteversion.


Assuntos
Artroplastia de Quadril , Prótese de Quadril , Luxações Articulares , Artroplastia de Quadril/efeitos adversos , Artroplastia de Quadril/métodos , Fenômenos Biomecânicos , Simulação por Computador , Articulação do Quadril/cirurgia , Humanos , Luxações Articulares/cirurgia , Amplitude de Movimento Articular
6.
Front Bioeng Biotechnol ; 10: 1023721, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36466333

RESUMO

Objectives: The study aimed to elucidate target cup orientation and stem anteversions to avoid impingement between the liner and stem neck even at hip rotation with adduction during the deeply flexed posture. Methods: A computer simulation analysis was performed on 32 total hip arthroplasty patients applying patient-specific orientation of the components and in vivo hip kinematics obtained from three-dimensional analysis of the squatting motion. The anterior/posterior liner-to-neck distance and impingement were evaluated based on a virtual change in internal/external rotation (0°-60°) and adduction/abduction (0°-20°) at actual maximum flexion/extension during squatting. Cutoff values of cup orientations, stem anteversion, and combined anteversion to avoid liner-to-neck impingements were determined. Results: The anterior liner-to-neck distance decreased as internal rotation or adduction increased, and the posterior liner-to-neck distance decreased as external rotation or adduction increased. Negative correlations were found between anterior/posterior liner-to-neck distances at maximum flexion/extension and internal/external rotation. Anterior/posterior liner-to-neck impingements were observed in 6/18 hips (18/56%) at 45° internal/external rotation with 20° adduction. The range of target cup anteversion, stem anteversion, and combined anteversion to avoid both anterior and posterior liner-to-neck impingements during squatting were 15°-18°, 19°-34°, and 41°-56°, respectively. Conclusion: Simulated hip rotations caused prosthetic impingement during squatting. Surgeons could gain valuable insights into target cup orientations and stem anteversion based on postoperative simulations during the deeply flexed posture.

7.
J Orthop Surg (Hong Kong) ; 28(3): 2309499020981779, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-33355033

RESUMO

INTRODUCTION: Assessment of scapular kinematics and the dynamics of the scapulohumeral rhythm (SHR) would be important for understanding pathologies of the shoulder and to inform treatment. Our aim in this study was to evaluate the SHR and scapular kinematics in patients with a rotator cuff tear (RCT), compared to a control group with healthy shoulders using image-matching techniques. MATERIALS AND METHODS: The shoulder kinematics of large or massive RCT patients were evaluated and compared to a control group with healthy shoulders. Radiographic surveillance was performed throughout the full range of external rotation and scapular plane abduction. Computed tomography imaging of the shoulder complex was performed, with three-dimensional image reconstruction and matching to the radiographs to measure three-dimensional positions and orientations. SHR and angular values of the scapula were measured. RESULTS: Scapular external rotation in the late phase of external rotation movement was greater in the RCT group than in the control group (p < 0.05), but with no difference in the SHR. During scapular plane abduction, there were significant differences in SHR, scapular posterior tilt and scapular upward rotation between the RCT and control group (p < 0.05). CONCLUSIONS: Regarding clinical relevance, this study clarified the differences of SHR and angular values of the scapula between the RCT and control group. These results underline the importance of assessment the SHR and scapular kinematics in individuals with a RCT. RCT is associated with specific compensation in the kinematics of the scapula and SHR during external rotation and scapular plane abduction, which could inform treatment.


Assuntos
Imageamento Tridimensional/métodos , Amplitude de Movimento Articular/fisiologia , Lesões do Manguito Rotador/cirurgia , Escápula/diagnóstico por imagem , Articulação do Ombro/cirurgia , Tomografia Computadorizada por Raios X/métodos , Adulto , Feminino , Humanos , Masculino , Lesões do Manguito Rotador/diagnóstico , Lesões do Manguito Rotador/fisiopatologia , Escápula/cirurgia , Ombro , Articulação do Ombro/diagnóstico por imagem , Articulação do Ombro/fisiopatologia
8.
J Orthop ; 21: 213-217, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32273659

RESUMO

PURPOSE: The purpose of this study was to determine the in vivo kinematics of healthy knees and those with osteoarthritis (OA), during twisting using density-based image-matching techniques. METHODS: Five healthy subjects and 26 patients with medial knee OA performed twisting under periodic X-ray imaging. RESULTS: The tibiofemoral rotation at the ipsilateral/contralateral twist in healthy and OA knees were 11° ± 9.3° externally/9.5° ± 5.6° internally (p < 0.05) and 4.4° ± 7.2° externally/2.7° ± 8° internally (p < 0.05), respectively. CONCLUSIONS: The kinematic analysis of OA knees during twisting revealed significantly smaller tibiofemoral rotation than those of healthy knees.

9.
J Med Case Rep ; 13(1): 11, 2019 Jan 12.
Artigo em Inglês | MEDLINE | ID: mdl-30635037

RESUMO

BACKGROUND: The in vivo assessment of the three-dimensional kinematics of the hip during dance activities in patients after total hip arthroplasty has not been previously reported. We evaluated the replaced hip kinematics during recreational classical ballet and hula dance using radiographic-based image-matching techniques. CASE PRESENTATION: A 58-year-old Japanese woman (patient 1; height, 157 cm; weight, 74.5 kg) and a 73-year-old Japanese woman (patient 2; height, 153 cm; weight, 48 kg) were still doing classical ballet and hula dance, respectively, after primary total hip arthroplasty. For ballet, there were gradual three-dimensional hip movements with 48° flexion, 36° abduction, and 49° external rotation in développé and 34° flexion, 29° abduction, and 43° external rotation in plié. For hula, there were small three-dimensional hip movements with 31° flexion, 15° adduction, and 11° external rotation in kao and 17° flexion, 11° adduction, and 11° external rotation in kaholo. No liner-to-neck contact was found in any dance activities. CONCLUSION: Both classical ballet and hula dance produced complex ranges of hip movements and activity-dependent kinematics. These kinematic data could be useful for recommending each patient with total hip arthroplasty to continue recreational dance activities.


Assuntos
Artroplastia de Quadril , Dança/fisiologia , Articulação do Quadril/fisiologia , Amplitude de Movimento Articular/fisiologia , Idoso , Fenômenos Biomecânicos/fisiologia , Feminino , Articulação do Quadril/diagnóstico por imagem , Humanos , Imageamento Tridimensional/métodos , Pessoa de Meia-Idade , Radiografia/métodos
10.
Clin Biomech (Bristol, Avon) ; 68: 175-181, 2019 08.
Artigo em Inglês | MEDLINE | ID: mdl-31229697

RESUMO

BACKGROUND: Dynamic hip kinematics during stationary cycling after total hip arthroplasty (THA) have been unclear. Furthermore, no computer simulation of optimal cup position based on in vivo kinematics has yet been assessed. METHODS: This study consisted of 7 patients who underwent unilateral primary THA for symptomatic osteoarthritis. Using a flat-panel X-ray detector, continuous radiographs were obtained during stationary cycling. We analyzed the three-dimensional replaced hip kinematics from the top to the bottom position of the crank using image-matching techniques and quantified minimum liner-to-stem neck distance. Simulation analyses with in vivo kinematics were performed to examine patient-specific optimal cup placement against prosthetic impingement. FINDINGS: During stationary cycling, pelvis showed 27.1° of posterior tilt on average without significant change. Hip flexed by 59.4° and 19.3° on average at the top and bottom positions, respectively. Minimum liner-to-neck distance was 8.8 mm on average at the bottom position. Liner-to-neck, bone-to-bone, or bone-to-component impingement was not observed at any positions in any hips. Simulation analysis of cup placement showed that larger cup anteversion, inclination, and use of elevated liner significantly decreased the minimum distance between posterior liner and stem neck. Cup anteversion of more than 30° with elevated liner could cause posterior liner-to-neck impingement at bottom position. INTERPRETATION: Stationary cycling after THA provides no excessive hip range of motion or liner-to-neck contact. Cup placement and use of elevated liner significantly influence the minimum liner-to-neck distance, in some cases simulating posterior prosthetic impingement.


Assuntos
Artroplastia de Quadril , Articulação do Quadril/cirurgia , Prótese de Quadril , Osteoartrite do Quadril/cirurgia , Amplitude de Movimento Articular , Rotação , Idoso , Fenômenos Biomecânicos , Simulação por Computador , Teste de Esforço , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Período Pós-Operatório , Desenho de Prótese
11.
Int J Surg Case Rep ; 42: 121-127, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-29245096

RESUMO

INTRODUCTION: Although combined evaluation of hip joint kinematics and bone morphology is necessary for accurate assessment of femoroacetabular impingement (FAI), there are no report which evaluated hip kinematics of pincer-type FAI. PRESENTATION OF CASE: The pre- and postoperative hip kinematics of a 46-year-old man, with a pincer-type FAI during squat were evaluated using image-matching techniques and the rim-neck distance was measured. Preoperative simulation of squatting was also performed using patient's bone models and healthy subject's kinematics data to detect the overlapping lesion between the acetabulum and the femur. Post-acetabuloplasty, right coxalgia during squat disappeared, and the Harris Hip Score improved from 79 to 92 at one year after surgery. Posterior pelvic tilt, femoral and hip flexion angle changed from 24.0°, 101.1°, and 70.8° to 23.3°, 92.6°, and 63.3°, respectively. The minimum rim-neck distance at maximum hip flexion improved from 1.8mm to 7.3mm. DISCUSSION: We could evaluate both of hip kinematics and morphology with image-matching techniques, and could visualize the clearance between the femoral head-neck junction and the acetabular rim. CONCLUSION: Image-matching techniques were clinically useful to assist surgeons in detecting the location of the impingement and confirming resection of the pincer lesion post-operatively.

12.
J Orthop Surg Res ; 13(1): 162, 2018 Jul 03.
Artigo em Inglês | MEDLINE | ID: mdl-29970119

RESUMO

BACKGROUND: The difference in in vivo kinematics before and after total hip arthroplasty (THA) for the same subjects and the clearance between the liner and neck during squatting have been unclear. The purpose of the present study was to clarify (1) the changes in the in vivo kinematics between prosthetic hips and osteoarthritis hips of the same subjects and (2) the extent of the liner-to-neck clearance during squatting under weight-bearing conditions. METHODS: This study consisted of 10 patients who underwent unilateral THA for symptomatic osteoarthritis. Using a flat-panel X-ray detector, we obtained continuous radiographs during squatting. We analyzed the hip joint's movements using three-dimensional-to-two-dimensional model-to-image registration techniques. We also quantified the minimum distance at maximum flexion and extension, and the minimum angle at maximum flexion between the liner and stem neck. RESULTS: The maximum hip flexion angles post-THA (80.7° [range, 69.4-98.6°]) changed significantly compared with the pre-THA values (71.7° [range, 55.2°-91.2°]). The pelvic tilt angle (posterior +, anterior-) at the maximum hip flexion post-THA (10.4° [range, - 6.7° to 26.9°]) was significantly smaller than that at pre-THA (16.6° [range, - 3° to 40.3°]). The minimum anterior and posterior liner-to-neck distances averaged 10.9 and 8.0 mm, respectively, which was a significant difference. The minimum liner-to-neck angle at maximum flexion averaged 34.7° (range, 20.7°-46.3°). No liner-to-neck contact occurred in any of the hips. CONCLUSION: THA increased the range of hip joint motion and the pelvis tilted anteriorly more after than before THA, with sufficient liner-to-neck clearance during squatting. These data may be beneficial for advising patients after THA regarding postoperative activity restrictions in daily life.


Assuntos
Artroplastia de Quadril , Articulação do Quadril/fisiopatologia , Articulação do Quadril/cirurgia , Osteoartrite do Quadril/fisiopatologia , Osteoartrite do Quadril/cirurgia , Idoso , Idoso de 80 Anos ou mais , Fenômenos Biomecânicos , Criança , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Postura , Amplitude de Movimento Articular
13.
Clin Biomech (Bristol, Avon) ; 60: 95-99, 2018 12.
Artigo em Inglês | MEDLINE | ID: mdl-30340151

RESUMO

BACKGROUND: There are no previous studies on the acromiohumeral distance in shoulders with large-to-massive full-thickness rotator cuff tears. In this study, the acromiohumeral distance in rotator cuff tear and healthy shoulders was measured using 3D-to-2D model-to-image registration techniques. METHODS: The dynamic glenohumeral kinematics during scapular plane abduction and axial rotation were analyzed in 11 rotator cuff tear patients and 10 healthy control subjects. Periodic radiographic images of scapular plane abduction and axial rotation were taken using a flat-panel radiograph image detector. Movements of the shoulder joint were assessed using radiographic images and computed tomography-derived digitally reconstructed radiographs. The acromiohumeral distance was defined as the shortest 3D distance between the acromion and the proximal humerus. FINDINGS: For scapular plane abduction, the rotator cuff tear group had significantly smaller acromiohumeral distance than the control group at 15°, 30°, 45°, 60°, 75°, 135°, and 150° of humeral abduction (P < 0.05 at each measured angle). For axial rotation in the adducted position, the rotator cuff tear group had significantly smaller acromiohumeral distance than the control group at each point between -20° and 40° of glenohumeral external rotation (P < 0.05 at each measured angle). INTERPRETATION: The minimum measured acromiohumeral distance was 0.9 mm in the rotator cuff tear shoulders and 2.1 mm in the healthy shoulders at 90° of scapular plane abduction. The findings are of clinical relevance because quantitative evaluation of the dynamic acromiohumeral distances in rotator cuff tear and healthy shoulders might provide important insight into subacromial impingement.


Assuntos
Lesões do Manguito Rotador/diagnóstico por imagem , Lesões do Manguito Rotador/fisiopatologia , Manguito Rotador/fisiopatologia , Síndrome de Colisão do Ombro/diagnóstico por imagem , Síndrome de Colisão do Ombro/fisiopatologia , Acrômio , Adulto , Idoso , Fenômenos Biomecânicos , Feminino , Voluntários Saudáveis , Humanos , Úmero/diagnóstico por imagem , Úmero/fisiopatologia , Processamento de Imagem Assistida por Computador , Imageamento Tridimensional , Masculino , Pessoa de Meia-Idade , Movimento , Radiografia , Rotação , Manguito Rotador/diagnóstico por imagem , Lesões do Manguito Rotador/cirurgia , Escápula/diagnóstico por imagem , Escápula/fisiopatologia , Ombro , Articulação do Ombro/diagnóstico por imagem , Articulação do Ombro/fisiopatologia , Tomografia Computadorizada por Raios X
14.
J Orthop Surg Res ; 13(1): 9, 2018 Jan 11.
Artigo em Inglês | MEDLINE | ID: mdl-29325577

RESUMO

BACKGROUND: No clear trend has emerged from the literature regarding three-dimensional (3D) translations of the humerus relative to the scapula in shoulders with rotator cuff tears (RCTs). The purpose of this study was to evaluate the kinematics of RCT shoulders using 3D-to-two-dimensional (2D) model-to-image registration techniques. METHODS: Dynamic glenohumeral kinematics during scapular plane abduction and axial rotation were analyzed in 11 RCT patients and 10 healthy control subjects. We measured the 3D kinematic parameters of glenohumeral joints using X-ray images and CT-derived digitally reconstructed radiographs. RESULTS: For scapular plane abduction, the humeral head center was positioned significantly more medially in shoulders with RCTs than in controls at 135° of humeral abduction (p = 0.02; RCTs versus controls: - 0.9 ± 1.6 versus 0.3 ± 1.3 mm). There was no significant difference in the superior/inferior translation of the humeral head center (p = 0.99). For axial rotation in adducted position, the humeral head center was positioned significantly more anteriorly in shoulders with RCTs than in controls at - 30° of glenohumeral external rotation (p < 0.0001; RCTs versus controls: 3.0 ± 1.7 versus 0.3 ± 1.5 mm). CONCLUSIONS: This study revealed the kinematics of shoulders with large to massive full-thickness RCTs: the humeral head center showed a medial shift at the late phase of scapular plane full abduction, and an anterior shift at the internal rotation position during full axial rotation. The kinematic data in this study, which describe the patterns of movement of shoulders with large to massive full-thickness RCTs, provide valuable information for future studies investigating glenohumeral translations in other pathological conditions of the shoulder. For clinical relevance, quantitative assessment of the dynamic kinematics of shoulders with RCTs might be a therapeutic indicator for achieving functional restoration.


Assuntos
Lesões do Manguito Rotador/fisiopatologia , Articulação do Ombro/fisiopatologia , Adulto , Idoso , Fenômenos Biomecânicos , Estudos de Casos e Controles , Feminino , Humanos , Cabeça do Úmero/diagnóstico por imagem , Cabeça do Úmero/patologia , Cabeça do Úmero/fisiopatologia , Imageamento Tridimensional/métodos , Masculino , Radiografia , Amplitude de Movimento Articular , Rotação , Lesões do Manguito Rotador/diagnóstico por imagem , Lesões do Manguito Rotador/patologia , Articulação do Ombro/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos
15.
J Orthop ; 15(2): 650-654, 2018 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-29881213

RESUMO

This study aimed to evaluate clinical outcomes and in vivo kinematics of bi-cruciate stabilized (BCS) total knee arthroplasty (TKA), using image-matching techniques. We analyzed tibiofemoral anteroposterior translation, axial rotation, and anterior/posterior cam-post contact for 22 BCS TKAs during squatting and stair-climbing. The functional activities on the 2011 Knee Society Score were significantly improved from 36 to 71. The tibiofemoral translation and axial rotation during squatting/stair-climbing were 16.1 mm/7.1 mm and 2.5° external/1.1° internal, respectively. Anterior/posterior cam-post contacts were observed during squatting (14%/96%) and stair-climbing (27%/96%). In conclusion, BCS TKA produced physiological sagittal plane kinematics during activities with favorable clinical outcomes.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA