Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
1.
Anesth Analg ; 131(4): 1210-1216, 2020 10.
Artigo em Inglês | MEDLINE | ID: mdl-32925342

RESUMO

BACKGROUND: The use of a shoulder roll to view the glottic opening during direct laryngoscopy in infants has been recommended but is not evidence based. METHODS: Twenty infants with normal airways, <6 months of age undergoing elective surgery under general anesthesia were randomized to undergo direct laryngoscopy first with a 2-inch vertical shoulder roll and then without, or vice versa. The primary outcome was the difference in the vertical distance between the angle of the laryngoscopist's eye and the operating room table in the 2 positions. Also, the views of the glottic opening in both positions were recorded for each infant and analyzed by a blinded investigator using the percent of glottic opening (POGO). RESULTS: Twenty infants completed the study without complications. The vertical distance did not differ significantly whether the shoulder roll was placed first or second, and there was no evidence of a differential carryover effect in the crossover design (P = .268). The main effect of the shoulder roll on the mean (95% confidence interval [CI]) vertical distances without 47.8 cm (43.5-52.1) and with the shoulder roll 37.2 cm (33.3-41) yielded a mean (95% CI) vertical difference of 10.6 cm (9.3-11.79; P = .0001). The median (interquartile range [IQR]) POGO scores without 100 [86.2, 100] and with the shoulder roll 97.5 [80, 100] did not differ (median difference [95% CI]: 0 [-20 to 0]; P = .39). CONCLUSIONS: A 2-inch shoulder roll lowers the line of sight of the glottic opening compared with no shoulder roll, without affecting the view of the glottic opening during laryngoscopy in infants.


Assuntos
Intubação Intratraqueal/métodos , Laringoscopia/métodos , Posicionamento do Paciente/métodos , Ombro , Anestesiologistas , Estudos Cross-Over , Procedimentos Cirúrgicos Eletivos/métodos , Feminino , Glote/anatomia & histologia , Humanos , Lactente , Recém-Nascido , Masculino , Método Simples-Cego , Resultado do Tratamento
2.
Anesth Analg ; 122(4): 928-34, 2016 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-26991611

RESUMO

BACKGROUND: Electromagnetic coil overheating, deformation, occlusion, and rupture during rapid infuser use have been previously reported. Although the etiology is unclear, prolonged machine use and reconstitution of citrated blood components with crystalloid solutions in the reservoir have been implicated. Lactated Ringer's (LR) solution is of particular concern as a diluent because of its calcium content. We sought to reproduce this failure mode using different infusion rates and different combinations of fluids for blood product reconstitution in the reservoir. We also introduced calcium chloride (CaCl2) to the mix to determine its role in macroscopic clot formation. METHODS: In this in vitro study, we conducted 2 series of experiments using the Belmont FMS 2000 rapid infuser and a reservoir. In series I, we submitted a mix of 1 U fresh thawed plasma (FTP) and 1 U red blood cells (RBC) with 500 mL of LR solution, normal saline, Plasma-Lyte A, or albumin 5% to a specific pump flow sequence. If neither a pump failure mode or self-shutoff (primary outcome) nor macroscopic clot (secondary outcome) was observed during a pump flow sequence, the sequences were repeated after first adding an additional 500 mL of the initially used crystalloid or albumin and then CaCl2 beginning with 200 mg and up to 1 g to the reservoir. In series II, 7 different crystalloid-blood product combinations were tested by using a variety of pump flow sequences with the same end points. Descriptive statistics and analysis of variance were used, and data were reported as means ± SD. RESULTS: We did not observe a Belmont pump failure mode (coil deformation, occlusion, or rupture) as previously described. In series I, the addition of CaCl2 200 mg resulted in macroscopic clots in 9 of 10 experiments (95% confidence interval, 0.55-0.99). The time to clot formation was 9.1 ± 2.3 minutes (99% confidence interval, 6.74-11.46) and did not differ between solutions used for component reconstitution. In series II, adding variable amounts of CaCl2 to 4 different combinations of FTP/RBC with Plasma-Lyte A or LR solution led to clot formation. The use of only FTP in 2 experiments with either LR solution or normal saline resulted in formation of a fibrin clot. In 1 experiment of LR solution mixed with RBCs alone, no clot was observed even after addition of 1 g CaCl2. After the observation of clot in the reservoir, the fluid empty alarm occurred once in series I, the overheating alarm occurred once in series II, and the high-pressure alarms occurred 3 times in each series, all accompanied by self-shutoff. CONCLUSIONS: In this in vitro study, we were unable to reproduce the failure mode characterized by coil overheating, deformation, and rupture previously reported with use of the FMS 2000. Addition of CaCl2 in the range of 200 mg caused macroscopic coagulation in the reservoir when added to crystalloids or albumin mixed with different combinations of blood products containing FTP.


Assuntos
Eritrócitos/química , Soluções Isotônicas/química , Substitutos do Plasma/química , Plasma/química , Coagulação Sanguínea/efeitos dos fármacos , Coagulação Sanguínea/fisiologia , Soluções Cristaloides , Humanos , Bombas de Infusão , Soluções Isotônicas/administração & dosagem , Substitutos do Plasma/administração & dosagem , Lactato de Ringer , Fatores de Tempo
3.
J Cardiothorac Vasc Anesth ; 28(1): 69-75, 2014 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-24290748

RESUMO

OBJECTIVE: The aim of this study was to determine the pertinent anesthetic considerations for patients undergoing surgical sympathectomy for electrical storm (incessant ventricular tachycardia (VT) refractory to traditional therapies). DESIGN: This is a retrospective review of a prospective database. SETTING: This single-center study took place in a university hospital setting. PARTICIPANTS: Twenty-six patients were enrolled. INTERVENTIONS: Fifteen patients underwent left-sided sympathectomy, whereas 11 patients underwent bilateral sympathectomy. MEASUREMENTS AND MAIN RESULTS: Anesthetic management of these patients was quite complex, requiring invasive monitoring, transesophageal echocardiography, one-lung ventilation, programming of cardiac rhythm management devices, and titration of vasoactive medications. Paired t test of hemodynamic data before, during, and after surgery showed no significant difference between preoperative and postoperative blood pressure values, regardless of whether the patient underwent unilateral or bilateral sympathectomy. Eight patients remained free of VT, three patients responded well to titration of oral medications, and one patient required 2 radiofrequency ablations after sympathectomy to control his VT. Three patients continued to have VT episodes, although reduced in frequency compared with before the procedure. Four patients were lost to followup. Overall, five patients within the cohort died within 30 days of the procedure. No patients developed any anesthetic complications or Horner's syndrome. The overall perioperative mortality (within the first 7 days of the procedure) was 2 of 26, or 7.7%. CONCLUSIONS: The anesthetic management of patients undergoing surgical sympathectomy for electrical storm can be quite complex, because these patients often present in a moribund and emergent state and cannot be optimized using current ACC/AHA guidelines. Expertise in invasive monitoring, transesophageal echocardiography, one-lung ventilation, cardiac rhythm device management, and pressor management is crucial for optimal anesthetic care.


Assuntos
Anestesia/métodos , Gânglios Simpáticos/cirurgia , Ganglionectomia/métodos , Taquicardia Ventricular/cirurgia , Toracoscopia/métodos , Idoso , Ecocardiografia Transesofagiana , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA