Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 26
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Med Klin Intensivmed Notfmed ; 115(3): 249-252, 2020 Apr.
Artigo em Alemão | MEDLINE | ID: mdl-30535900

RESUMO

Acute necrotizing esophagitis ("black esophagus") is defined as complete necrosis of the esophageal mucosa, which typically affects the entire circumference. We report a case of a healthy 62-year-old woman, who became hemodynamically unstable due to stress cardiomyopathy with acute right heart failure. Transfusion-dependent anemia occurred 24 h later and an upper gastrointestinal endoscopy revealed a black discoloured mucosa of the distal esophagus. After hemodynamic stabilization and treatment with proton pump inhibitors and sucralfate, complete healing of the esophageal mucosa was achieved.


Assuntos
Cardiomiopatias , Esofagite/diagnóstico , Esofagite/tratamento farmacológico , Esofagite/terapia , Cardiomiopatia de Takotsubo , Doença Aguda , Feminino , Humanos , Pessoa de Meia-Idade
2.
Clin Res Cardiol ; 109(1): 1-12, 2020 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-31410547

RESUMO

Indications for TF-TAVI (transfemoral transcatheter aortic valve implantation) are rapidly changing according to increasing evidence from randomized controlled trials. Present trials document the non-inferiority or even superiority of TF-TAVI in intermediate-risk patients (STS-Score 4-8%) as well as in low-risk patients (STS-Score < 4%). However, risk scores exhibit limitations and, as a single criterion, are unable to establish an appropriate indication of TF-TAVI vs transapical TAVI vs SAVR (surgical aortic valve replacement). The ESC (European Society of Cardiology)/EACTS (European Association for Cardio-Thoracic Surgery) guidelines 2017 and the German DGK (Deutsche Gesellschaft für Kardiologie)/DGTHG (Deutsche Gesellschaft für Thorax-, Herz- und Gefäßchirurgie) commentary 2018 offer a framework for the selection of the best therapeutic method, but the individual decision is left to the discretion of the heart teams. An interdisciplinary TAVI consensus group of interventional cardiologists of the ALKK (Arbeitsgemeinschaft Leitende Kardiologische Krankenhausärzte e.V.) and cardiac surgeons has developed a detailed consensus on the indications for TF-TAVI to provide an up-to-date, evidence-based, comprehensive decision matrix for daily practice. The matrix of indication criteria includes age, risk scores, contraindications against SAVR (e.g., porcelain aorta), cardiovascular criteria pro TAVI, additional criteria pro TAVI (e.g., frailty, comorbidities, organ dysfunction), contraindications against TAVI (e.g., endocarditis) and cardiovascular criteria pro SAVR (e.g., bicuspid valve anatomy). This interdisciplinary consensus may provide orientation to heart teams for individual TAVI-indication decisions. Future adaptations according to evolving medical evidence are to be expected. Interdisciplinary consensus on indications for transfemoral transcatheter aortic valve implantation (TF-TAVI).


Assuntos
Estenose da Valva Aórtica/cirurgia , Substituição da Valva Aórtica Transcateter/métodos , Consenso , Artéria Femoral , Humanos , Seleção de Pacientes , Ensaios Clínicos Controlados Aleatórios como Assunto
3.
Herzschrittmacherther Elektrophysiol ; 16(1): 28-31, 2005 Mar.
Artigo em Alemão | MEDLINE | ID: mdl-15824873

RESUMO

Cardiac resynchronization therapy (CRT) is now considered an established therapy for patients with chronic heart failure in the presence of a wide QRS complex. Though proarrhythmic effects have been described in a few cases, CRT did not increase the frequency of ventricular tachyarrhythmias in prospective studies. In patients on CRT therapy, persistent atrial fibrillation sometimes converts back to sinus rhythm, possibly dependent on the duration of atrial fibrillation.


Assuntos
Arritmias Cardíacas/terapia , Estimulação Cardíaca Artificial/métodos , Medição de Risco/métodos , Disfunção Ventricular Esquerda/prevenção & controle , Arritmias Cardíacas/complicações , Ensaios Clínicos como Assunto , Humanos , Guias de Prática Clínica como Assunto , Padrões de Prática Médica , Prognóstico , Recuperação de Função Fisiológica , Fatores de Risco , Resultado do Tratamento , Disfunção Ventricular Esquerda/etiologia
4.
Herzschrittmacherther Elektrophysiol ; 26(2): 75-81, 2015 Jun.
Artigo em Alemão | MEDLINE | ID: mdl-26041117

RESUMO

Without the concept of primary prevention of sudden cardiac death, therapy with implantable defibrillators would not have reached the current distribution and clinical importance. Most of the scientific evidence of the concept is based on clinical studies from 1996-2005. More than 75 % of all defibrillator implantations are currently indicated as primary prevention. Implantable converter-defibrillator (ICD) therapy in the primary prevention of sudden cardiac death was incorporated into scientific guidelines starting in 1998. The historical development of the indications for ICD therapy in the primary prevention of sudden cardiac death is presented, reflecting major results of controlled, randomized clinical studies and guideline discussions.


Assuntos
Tomada de Decisão Clínica/métodos , Morte Súbita Cardíaca/prevenção & controle , Desfibriladores Implantáveis , Seleção de Pacientes , Prevenção Primária/métodos , Medição de Risco/métodos , Medicina Baseada em Evidências , Humanos , Resultado do Tratamento
5.
Physiol Meas ; 36(5): 1047-61, 2015 May.
Artigo em Inglês | MEDLINE | ID: mdl-25903155

RESUMO

The HAWAI registry evaluated the role of heart rate variability in predicting the occurrence of ventricular tachycardia and fibrillation (VT/VF) and sinus tachycardia in patients with an implantable cardioverter-defibrillator (45 patients with 155 RR recordings). A significant decrease of the mean value of all RR intervals (MeanNN) was observed in the period starting 20 and 40 min prior to VT/VF and sinus tachycardia, respectively. The standard deviation of RR intervals (SDNN) and the power at low frequency (LF) were the only parameters with significant changes prior to VT/VF. For sinus tachycardia, the root mean square of successive differences of all successive RR intervals (r-MSSD) and the power at low and high frequency (HF) decreased, whereas SDNN and the power at very low frequency increased. Comparison of RR recordings preceding VT/VF and sinus tachycardia revealed significant differences of the MeanNN, SDNN, r-MSSD, LF and HF. Based on a classification and regression tree analysis, MeanNN, SDNN and r-MSSD showed a sensitivity of 94.4% and a specificity of 50.6% as predictors of VT/VF. Our results suggest that the temporal changes in heart rate before an arrhythmic event can be used to predict the occurrence of VT/VF. These parameters may be used to optimize pacing therapies designed to prevent VT/VF recurrences as well as for improving device-based discriminators for VT/VF and sinus tachycardia.


Assuntos
Desfibriladores Implantáveis , Frequência Cardíaca , Sistema de Registros/estatística & dados numéricos , Taquicardia Sinusal/fisiopatologia , Taquicardia Sinusal/terapia , Taquicardia Ventricular/fisiopatologia , Taquicardia Ventricular/terapia , Eletrocardiografia , Feminino , Hospitais , Humanos , Masculino , Pessoa de Meia-Idade
6.
Am J Cardiol ; 83(5B): 158D-160D, 1999 Mar 11.
Artigo em Inglês | MEDLINE | ID: mdl-10089859

RESUMO

Implantable cardioverter defibrillators (ICDs) and ventricular assist devices (VADs) have been used as a bridge to cardiac transplantation. In selected patients, the combined implantation may be required. This study was motivated by a case of a 33-year-old female patient with giant cell myocarditis who died of ventricular tachyarrhythmias after having been placed on a VAD with which she had been treated on an out-of-hospital basis for a prolonged period of time. A subsequent retrospective analysis of our data showed that, of 73 patients who had to be bridged mechanically (54 Novacor, 12 TCI Heartmate, 4 Thoratec, 3 Medos) in our institution between 1993 and 1998, 10 patients had undergone defibrillator implantation either before (n = 8) or after (n = 2) implantation of a VAD. The cases are presented, and the feasibility of the combination therapy discussed.


Assuntos
Desfibriladores Implantáveis , Insuficiência Cardíaca/terapia , Transplante de Coração , Coração Auxiliar , Adulto , Terapia Combinada , Morte Súbita Cardíaca/prevenção & controle , Feminino , Alemanha , Insuficiência Cardíaca/etiologia , Insuficiência Cardíaca/mortalidade , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Taxa de Sobrevida , Listas de Espera
7.
J Heart Lung Transplant ; 18(10): 963-71, 1999 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-10561107

RESUMO

BACKGROUND: The aim of this study was to investigate the role of metallothionein in cardiac transplants in relation to cytokines and allograft function. Recent studies have revealed an association of allograft dysfunction with elevated proinflammatory cytokines independent of cellular rejection. In animal experiments, cytokines induced overexpression of metallothionein, a low-molecular-weight protein implicated in cellular stress response. METHODS: In 105 consecutive biopsies from 15 patients during the first 3 months after heart transplantation, metallothionein expression was investigated immunohistochemically. Its relation to serum interleukin-6, tumor necrosis factor-alpha, interleukin-2 (IL-2), soluble interleukin-2 receptor rejection, and echocardiographic parameters was determined. Forty-three biopsies of 12 patients with idiopathic ventricular tachycardia served as controls. RESULTS: Metallothionein expression was demonstrated in small vessels, cardiomyocytes, fibrocytes, and interstitial round cells. A positive relation between interleukin-6 levels and the number of metallothionein-positive small vessels (p < 0.028) was observed. Patients with lower serum IL-2 levels showed significantly higher numbers of metallothionein-positive small vessels (p < 0.043). Grafts with prolonged ischemic time (>150 minutes) showed a significantly higher myocardial metallothionein score (p < 0.021). Metallothionein expression was associated with lower fractional shortening, larger left ventricular end-systolic diameter, and lower mean arterial pressure but not with acute cellular rejection. CONCLUSIONS: Metallothionein expression is associated with elevated interleukin-6 and decreased interleukin-2 serum levels and left ventricular allograft dysfunction in the absence of rejection.


Assuntos
Citocinas/sangue , Transplante de Coração/fisiologia , Metalotioneína/metabolismo , Miocárdio/metabolismo , Doença Aguda , Biópsia , Ecocardiografia , Rejeição de Enxerto/metabolismo , Rejeição de Enxerto/patologia , Transplante de Coração/diagnóstico por imagem , Transplante de Coração/patologia , Transplante de Coração/estatística & dados numéricos , Humanos , Imuno-Histoquímica , Terapia de Imunossupressão/métodos , Modelos Lineares , Isquemia Miocárdica/metabolismo , Isquemia Miocárdica/patologia , Miocárdio/patologia , Estatísticas não Paramétricas , Taquicardia Ventricular/metabolismo , Taquicardia Ventricular/patologia , Fatores de Tempo , Transplante Homólogo
8.
ASAIO J ; 46(6): 792-4, 2000.
Artigo em Inglês | MEDLINE | ID: mdl-11110284

RESUMO

We report on a 24 year old man with a Novacor left ventricular assist device (LVAD) who underwent long-term treatment with intravenous recombinant hirudin due to a heparin induced thrombocytopenia (HIT II) after suffering from an ischemic stroke.


Assuntos
Anticoagulantes/administração & dosagem , Coração Auxiliar , Hirudinas/administração & dosagem , Adulto , Transplante de Coração , Heparina/efeitos adversos , Humanos , Masculino , Proteínas Recombinantes/administração & dosagem , Acidente Vascular Cerebral/etiologia , Trombocitopenia/induzido quimicamente
9.
Artigo em Alemão | MEDLINE | ID: mdl-21170654

RESUMO

In patients with hypertrophic cardiomyopathy (HOCM), the decision for an implantable cardioverter-defibrillator (ICD) depends highly on the exact identification of the etiology of syncope. In this article, the case of a patient with HOCM and syncope is reported. Invasive pressure measurement was used to diagnose a typical case of cough syncope as the cause of the syncope.


Assuntos
Cardiomiopatia Hipertrófica/complicações , Cardiomiopatia Hipertrófica/terapia , Tosse/complicações , Tosse/terapia , Desfibriladores Implantáveis , Síncope/etiologia , Síncope/prevenção & controle , Idoso , Cardiomiopatia Hipertrófica/diagnóstico , Tosse/diagnóstico , Diagnóstico Diferencial , Humanos , Masculino , Síncope/diagnóstico , Resultado do Tratamento
10.
Heart ; 94(8): 1026-31, 2008 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-17984216

RESUMO

OBJECTIVE: To investigate predisposing factors for cardiac resynchronisation therapy (CRT) response. DESIGN: Single-centre study. SETTING: University hospital in Germany. PATIENTS: 122 consecutive patients with heart failure (mean (SD) age 65 (11) years; ischaemic/non-ischaemic 41%/55%; New York Heart Association (NYHA) class 3.1 (0.3); left ventricular ejection fraction 24.4 (8.1)%; QRS width 170 (32) ms, quality of life (QoL) 43.5 (19.2)) with an indication for CRT and demonstrated left ventricular dyssynchrony by echocardiography including tissue Doppler imaging. INTERVENTIONS: Besides laboratory testing of clinical variables, results of ECG, echocardiography including tissue Doppler imaging, invasive haemodynamics, measures of QoL and of exercise capacity were obtained before CRT implantation and during follow-up. MAIN OUTCOME MEASURE: Responders were predefined as patients with improvement by one or more NYHA functional class or reduction of left ventricular end-systolic volume by 10% or more during follow-up. Mean (SD) follow-up was 418 (350) days. RESULTS: Overall, 70.5% of patients responded to CRT. Responders had a significantly improved survival compared with non-responders (96.2% vs 45.5%, log-rank p<0.001). On univariate analysis, left ventricular end-diastolic diameter, left ventricular end-systolic diameter (LVESD), E/A ratio, a restrictive filling pattern, mean pulmonary artery pressure, pulmonary capillary pressure, N-terminal pro-brain natriuretic peptide and Vo(2)max were significant predictors of outcome. On multivariate analyses, LVESD (p = 0.009; F = 7.83), pulmonary capillary pressure (p = 0.015, F = 6.61) and a restrictive filling pattern (p = 0.026, F = 5.707) remained significant predictors of response. CONCLUSIONS: Despite treatment according to present guidelines nearly 30% of patients had no benefit from CRT treatment in a clinical setting. On multivariate analyses, patients with an increased left ventricular end-systolic diameter and concomitant diastolic dysfunction had a significantly worse outcome.


Assuntos
Estimulação Cardíaca Artificial , Insuficiência Cardíaca/terapia , Disfunção Ventricular Esquerda/terapia , Idoso , Diástole , Ecocardiografia Doppler/métodos , Eletrocardiografia , Feminino , Seguimentos , Insuficiência Cardíaca/complicações , Insuficiência Cardíaca/fisiopatologia , Hemodinâmica , Humanos , Masculino , Pessoa de Meia-Idade , Prognóstico , Análise de Sobrevida , Resultado do Tratamento , Disfunção Ventricular Esquerda/diagnóstico , Disfunção Ventricular Esquerda/etiologia , Disfunção Ventricular Esquerda/fisiopatologia
11.
Z Kardiol ; 94(9): 588-91, 2005 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-16142519

RESUMO

Implantation of a transvenous device in patients with a tricuspid valve replacement or a complex congenital heart disease with no access to the right ventricle represents problems. The lack of access to the right ventricle might preclude transvenous placement of a defibrillation lead at ICD implantation. A young patient (21 years) with a history of severe chest trauma with rupture of the tricuspid valve as well as the right coronary artery and consecutive inferior myocardial infarction was initially treated with tricuspid valve replacement (St Jude Medical artificial prosthesis, 33 mm) and a bypass graft to the right coronary artery. Four years later, the patient was admitted with a hemodynamically not tolerated ventricular tachycardia (VT: CL 250 ms, LBBB, left axis). The VT could be reproduced during electrophysiological testing. An ICD was implanted subpectorally in combination with a transvenous active fixation ICD lead. The transvenous ICD lead was placed via a guiding catheter into a coronary sinus branch (middle cardiac vein). Acceptable pacing and sensing values could be obtained. The defibrillation threshold was 25 J. In conclusion transvenous ICD lead implantation into a side branch of the coronary sinus in combination with a pectorally implanted "active can" ICD device seems to be an alternative approach. This approach may avoid implantation of additional subcutaneous defibrillation leads or even thoracotomy for ICD implantation.


Assuntos
Desfibriladores Implantáveis , Cardioversão Elétrica/instrumentação , Próteses Valvulares Cardíacas , Infarto do Miocárdio/cirurgia , Implantação de Prótese/métodos , Taquicardia Ventricular/prevenção & controle , Valva Tricúspide/cirurgia , Adulto , Cateterismo Cardíaco , Vasos Coronários/cirurgia , Cardioversão Elétrica/métodos , Eletrodos Implantados , Humanos , Infarto do Miocárdio/complicações , Resultado do Tratamento
12.
Z Kardiol ; 88(4): 290-5, 1999 Apr.
Artigo em Alemão | MEDLINE | ID: mdl-10408033

RESUMO

A case of atypical hypertrophic cardiomyopathy (HCM) with a calcified apical thrombus is presented. A 42 year old asymptomatic patient was admitted for evaluation of an abnormal electrocardiogram (ECG) which was recorded when the patient suffered from a bronchitis. The ECG showed giant negative T-waves in leads II, III, aVF, V3 to V6 associated with high QRS voltages in the precordial leads. The chest X-ray and fluoroscopy demonstrated a calcification in projection to the apical region of the heart. Echocardiography and the left ventricular (LV) cineangiography showed hypertrophy of the apical LV myocardium and an obliteration of the apical LV cavity. Magnetic resonance imaging identified a calcified thrombus in the apical cavity of the LV in the setting of an atypical HCM.


Assuntos
Calcinose/diagnóstico , Cardiomiopatia Hipertrófica/diagnóstico , Trombose/diagnóstico , Função Ventricular Esquerda/fisiologia , Adulto , Calcinose/fisiopatologia , Cateterismo Cardíaco , Cardiomiopatia Hipertrófica/fisiopatologia , Diagnóstico por Imagem , Eletrocardiografia , Ventrículos do Coração/patologia , Ventrículos do Coração/fisiopatologia , Humanos , Masculino , Trombose/fisiopatologia
13.
J Cardiovasc Electrophysiol ; 12(3): 356-60, 2001 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-11291811

RESUMO

INTRODUCTION: The need to access the right ventricle might preclude transvenous placement of a defibrillation lead at implantable cardioverter defibrillator (ICD) placement, especially in small children or children with complex congenital heart defects. We investigated a subcutaneous array lead in addition to an abdominally placed "active can" ICD device in two children to avoid a thoracotomy. METHODS AND RESULTS: The first child (age 12 years, 138 cm, 41 kg) had transposition of the great arteries with a subsequent surgical intra-atrial correction by the Mustard technique. The second child (age 14 years, 161 cm, 54 kg) had a single atrium and a single ventricle, d-transposition of the aorta, and atresia of the main pulmonary artery with a surgical anastomosis between the aorta and the right pulmonary artery by the Cooley technique. The defibrillation threshold was 18 J and <20 J at initial implantation and at generator replacement in the first patient and 20 J in the second patient. During follow-up of 6 years and 1 month, respectively, no ICD-related complications occurred. CONCLUSION: In children in whom endocardial, right ventricular placement of a defibrillation lead is precluded, defibrillation is possible and safe between an abdominally placed "active can" ICD device and a subcutaneous array lead. This approach may avoid a thoracotomy in children with no possibility for transvenous ICD placement.


Assuntos
Desfibriladores Implantáveis , Cardiopatias Congênitas/cirurgia , Procedimentos Cirúrgicos Minimamente Invasivos , Abdome/cirurgia , Adolescente , Criança , Procedimentos Cirúrgicos Dermatológicos , Humanos , Radiografia Torácica , Toracotomia
14.
Z Kardiol ; 93(10): 799-806, 2004 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-15492895

RESUMO

The aim of this study was to assess the impact of stroke volume (SV) on mitral annular velocities derived from tissue Doppler imaging (TDI). To this end, conventional echocardiographic variables and TDI derived mitral annular velocities (S', E', A') were obtained in 14 patients (pts) with increased SV (due to primary mitral (n=12) (ISV group)), in 41 pts with reduced SV (due to ischemic (n=27) or dilated cardiomyopathy (n=9) or hypertensive heart disease (n=5) (RSV group)) and 29 asymptomatic controls with normal SV (CON group). Systolic (S') and early diastolic (E') mitral annular velocities were elevated in the ISV group in the comparison to the CON group, but were significantly reduced in the RSV group. Late diastolic annular velocities (A') did not differ between the ISV and the CON group, but were lowest in the RSV group. On simple linear regression analysis, SV was significantly related to S' (r=0.74, p<0.001), to E' (r=0.74, p<0.001) and to A' (r=0.43, p<0.01). On multiple regression analysis, SV was a stronger independent predictor of S' and E' than conventional systolic or diastolic echocardiographic variables. Thus, stroke volume has a significant impact on TDI derived systolic (S') and early diastolic (E') mitral annular velocities. This should be considered, when TDI is used in the evaluation of LV performance or in the estimation of filling pressures.


Assuntos
Velocidade do Fluxo Sanguíneo/fisiologia , Ecocardiografia Doppler em Cores , Ecocardiografia Doppler de Pulso , Cardiopatias/diagnóstico por imagem , Valva Mitral/diagnóstico por imagem , Volume Sistólico/fisiologia , Adulto , Idoso , Insuficiência da Valva Aórtica/diagnóstico por imagem , Insuficiência da Valva Aórtica/fisiopatologia , Cardiomiopatia Dilatada/diagnóstico por imagem , Cardiomiopatia Dilatada/fisiopatologia , Cardiomiopatia Hipertrófica/diagnóstico por imagem , Cardiomiopatia Hipertrófica/fisiopatologia , Doença das Coronárias/diagnóstico por imagem , Doença das Coronárias/fisiopatologia , Feminino , Cardiopatias/fisiopatologia , Humanos , Hipertensão/complicações , Hipertensão/diagnóstico por imagem , Hipertensão/fisiopatologia , Masculino , Pessoa de Meia-Idade , Insuficiência da Valva Mitral/diagnóstico por imagem , Insuficiência da Valva Mitral/fisiopatologia , Contração Miocárdica/fisiologia , Variações Dependentes do Observador , Disfunção Ventricular Esquerda/diagnóstico por imagem , Disfunção Ventricular Esquerda/fisiopatologia
15.
Europace ; 2(2): 154-9, 2000 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-11225941

RESUMO

AIMS: In patients with implantable cardioverter-defibrillators (ICD), the goals of lowering the defibrillation threshold (DFT) can be achieved by means of higher defibrillation safety margins, more rapid charging of capacitors, improved battery longevity, implying smaller devices. Whether an increase in the electrically active surface of ICD leads by fractal coating results in decreased DFTs is unknown. METHODS AND RESULTS: In this prospective randomized cross-over study the defibrillation efficacy of a novel right ventricular endocardial defibrillation electrode fractally coated with iridium was compared with an uncoated but otherwise identical electrode in 30 patients undergoing ICD implantation. In each patient, DFT testing was performed twice according to a binary search protocol introducing the two different electrodes in a random order. The mean DFT was 8.4 +/- 4.1 J with the fractally coated lead and 9.6 +/- 3.6 J using the uncoated lead. The improvement of 1.2 J was statistically not significant (P = 0.11). No differences were observed between the patients with an improved DFT (n =12) and those with an unchanged or worsened DFT (n = 18) concerning age, underlying cardiac disease, NYHA class, or left ventricular ejection fraction, respectively. CONCLUSION: Increasing the electrical surface of defibrillation leads by fractal coating does not lead to a substantial clinically relevant reduction in defibrillation thresholds. Defibrillation impedance is not influenced by the increased electrical surface of the defibrillation lead.


Assuntos
Desfibriladores Implantáveis , Fibrilação Ventricular/terapia , Adulto , Idoso , Estudos Cross-Over , Desenho de Equipamento , Feminino , Fractais , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos
16.
Transpl Int ; 12(2): 141-4, 1999.
Artigo em Inglês | MEDLINE | ID: mdl-10363597

RESUMO

Optimal allocation of donor organs is an ongoing matter of debate. We report on the impact of the foundation of UNI NRW, a close transplant collaboration of seven university centers with the intention of improving donor organ allocation, on the heart transplant program in Münster. All donor organs retrieved were offered first to the patients within this region before going into the Eurotransplant (ET) Foundation pool. The heart transplant program data were prospectively (for 1997) and retrospectively (for 1996) analyzed with regard to donor organ availability and allocation. There was a slight decrease in the number of donor hearts offered and accepted within the UNI NRW region in 1997 as compared to in 1996. However, due to the significantly lower organ export rate, the number of heart transplantations performed in UNI NRW rose from 47 to 72 procedures. In Münster, only six donor organs (16%) were procured from outside UNI NRW in 1997, and these were, in part, due to special urgency requests. In conclusion, the institutionalization of UNI NRW within the framework of ET offers more flexibility, decreases total ischemic time, and may help to lower costs.


Assuntos
Transplante de Coração/estatística & dados numéricos , Doadores de Tecidos , Europa (Continente) , Alemanha , Hospitais Universitários , Humanos , Estudos Prospectivos , Estudos Retrospectivos , Doadores de Tecidos/provisão & distribuição , Obtenção de Tecidos e Órgãos/organização & administração , Obtenção de Tecidos e Órgãos/estatística & dados numéricos
17.
J Cardiovasc Electrophysiol ; 12(8): 921-7, 2001 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-11513444

RESUMO

INTRODUCTION: Placement of implantable cardioverter defibrillators (ICDs) has been simplified by using the shell of a pectorally implanted ICD as a defibrillation electrode in combination with an endocardial right ventricular defibrillation lead. However, a sufficiently low defibrillation threshold (DFT) cannot be obtained in a few patients. Therefore, alternative approaches were systematically tested in the Active Can versus Array Trial (ACAT). METHODS AND RESULTS: In the first of two prospective randomized studies, the DFT of a subcutaneous left dorsolateral array anode introduced from a pectoral incision was compared to that of a standard active can anode in 68 patients. Intraoperatively, the DFT was determined twice in each patient using either the active can or, in patients with a subcutaneous array lead, once with all three fingers and once omitting the middle finger of the array. The second prospective randomized study included 40 patients. DFT also was determined twice in each patient using an active can in a left pectoral position as anode alone and combined with a left dorsolateral array electrode with two fingers. In ACAT I, stored energy at DFT decreased from 13.1+/-7.7 J (active can) to 9.6+/-6.1 J (three-finger array lead) (P = 0.04), impedance decreased from 53+/-8 ohms to 40+/-6 ohms (P < 0.0001). Omitting the middle finger of the array lead, stored energy at DFT increased by 0.9 J (P = 0.47) and impedance by 2 ohm (P < 0.0001). In ACAT II, DFT and impedance using an active can device were significantly lower when a two-finger array lead was added that decreased stored energy at DFT from 10.1+/-5.2 J to 6.9+/-3.9 J (P = 0.001) and impedance from 56+/-5 1 to 42+/-5 l (P < 0.0001). CONCLUSION: In combination with a right ventricular defibrillation electrode, a left pectoral subcutaneous array lead improves defibrillation efficacy if used instead of, or in addition to, a left pectoral active can ICD device. Implantation of the array lead can be simplified by using two instead of three fingers, without a significant loss of defibrillation efficacy.


Assuntos
Desfibriladores Implantáveis , Cardioversão Elétrica/instrumentação , Eletrodos Implantados , Adulto , Idoso , Idoso de 80 Anos ou mais , Doenças Cardiovasculares/terapia , Estudos Cross-Over , Técnicas Eletrofisiológicas Cardíacas , Segurança de Equipamentos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Guias de Prática Clínica como Assunto , Estudos Prospectivos , Fatores de Tempo , Resultado do Tratamento
18.
Pacing Clin Electrophysiol ; 24(3): 345-51, 2001 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-11310304

RESUMO

In patients with ICDs, rapid VTs are usually treated with shocks. It is unknown, if antitachycardia pacing (ATP) delivered once for rapid VT during capacitor charging can avoid painful shocks without increasing the risk of syncope. In patients in whom rapid monomorphic VT (cycle length 300-220 ms) could be reproducibly induced during predischarge ICD testing, the success of cardioversion (defibrillation threshold plus 10 J) and a single ATP attempt (burst with 8 or 16 stimuli) was compared using a randomized crossover study design. Consciousness of the patients was checked by the signal from a button constantly pushed by the patient. In 20 patients (ejection fraction 0.50 +/- 0.19) rapid VTs (253 +/- 26 ms) were reproducibly induced. A single burst successfully terminated 11 (55%) of 20 rapid VTs, 6 episodes could not be terminated with a single burst pacing and 3 VTs accelerated. Rapid VTs not terminated by ATP were significantly faster than those that could be terminated (246 vs 258 ms, P = 0.026). Cardioversion (19 +/- 3 J) terminated the VTs in all cases. No patient suffered syncope during rapid VTs. A single ATP may terminate rapid VT with cycle lengths < 300 ms in 55% of patients without increasing the risk of syncope. Therefore, in rapid VTs one attempt of ATP may be suitable as an additional therapy option during ICD capacitor charging to avoid painful shocks without compromise of safety. Thus, future ICDs should implement the option of ATP during charging of capacitors.


Assuntos
Estimulação Cardíaca Artificial/efeitos adversos , Estimulação Cardíaca Artificial/métodos , Traumatismos por Eletricidade/prevenção & controle , Marca-Passo Artificial/efeitos adversos , Taquicardia Ventricular/prevenção & controle , Adulto , Idoso , Distribuição de Qui-Quadrado , Estudos Cross-Over , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estatísticas não Paramétricas
19.
Heart ; 89(10): 1157-62, 2003 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-12975406

RESUMO

BACKGROUND: Patients resuscitated from ventricular tachyarrhythmias benefit from implantable cardioverter-defibrillators (ICDs) as opposed to medical treatment. Patients with increased QRS duration receiving an ICD in the presence of heart failure are at greatest risk of cardiac death and benefit most from ICD therapy. OBJECTIVE: To determine whether an increased QRS duration predicts cardiac mortality in ICD recipients. DESIGN: Consecutive patients with heart failure in New York Heart Association functional class III were grouped according to QRS duration (< 150 ms, n = 139, group 1; v > or = 150 ms, n = 26, group 2) and followed up for (mean (SD)) 23 (20) months. PATIENTS: 165 patients were studied (80% men, 20% women); 73% had coronary artery disease and 18% had dilated cardiomyopathy. Their mean age was 62 (10) years and mean ejection fraction (EF) was 33 (14)%. They presented either with ventricular tachycardia (VT) or ventricular fibrillation (VF). MAIN OUTCOME MEASURES: Overall and cardiac mortality; recurrence rates of VT, fast VT, or VF. RESULTS: Mean left ventricular EF did not differ between group 1 (33 (13)%) and group 2 (31 (15)%). Forty patients died (34 cardiac deaths). There was no difference in survival between patients with EF > 35% and < or = 35%. Cardiac mortality was significantly higher in group 2 than in group 1 (31.3% at 12 months and 46.6% at 24 months, v 9.5% at 12 months and 18.2% at 24 months, respectively; p = 0.04). The recurrence rate of VT was similar in both groups. CONCLUSIONS: Within subgroups at highest risk of cardiac death, QRS duration-a simple non-invasive index-predicts outcome in ICD recipients in the presence of heart failure.


Assuntos
Desfibriladores Implantáveis , Insuficiência Cardíaca/terapia , Fibrilação Ventricular/terapia , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Morte Súbita Cardíaca/prevenção & controle , Eletrocardiografia , Feminino , Insuficiência Cardíaca/mortalidade , Insuficiência Cardíaca/fisiopatologia , Humanos , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Estudos Prospectivos , Recidiva , Fatores de Risco , Volume Sistólico/fisiologia , Análise de Sobrevida
20.
Eur Heart J ; 21(2): 162-9, 2000 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-10637090

RESUMO

AIMS: Benefits and complications of postoperative implantable cardioverter-defibrillator tests are controversial matters. This study sought to assess the necessity of defibrillation function tests after implantation. METHODS AND RESULTS: We retrospectively analysed 1007 implantable cardioverter-defibrillator tests in 587 systems and 556 patients. Nine hundred and thirty implantable cardioverter-defibrillator tests (89.4%) were routinely performed. Seventy-one tests (7%) were performed after a change in the antiarrhythmic drug regimen and six tests (0.60%) because of a suspected dysfunction of the implantable cardioverter-defibrillator. During routine tests, four systems (0.4%) failed to defibrillate the patient. However, in all but one test, abnormalities of the system had been observed before the test. After the addition of antiarrhythmic drugs, two of 71 implantable cardioverter-defibrillator systems (2.8%) failed to defibrillate the patient. One of six systems tested due to a suspected dysfunction failed to defibrillate the patient. During 16 tests (1.6%), complications occurred. CONCLUSIONS: Our experience demonstrates that postoperative tests of the defibrillation function of implantable cardioverter-defibrillators rarely reveal dysfunctions. As testing is unpleasant for the patient and not free of complications, tests might be restricted to those patients in whom a dysfunction is suspected and to those patients in whom class I or class III antiarrhythmic drugs have been added to the antiarrhythmic drug regimen.


Assuntos
Desfibriladores Implantáveis , Testes Diagnósticos de Rotina , Fibrilação Ventricular/terapia , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Criança , Análise de Falha de Equipamento , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Fatores de Risco , Fibrilação Ventricular/diagnóstico
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA