Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
BMC Pulm Med ; 24(1): 54, 2024 Jan 25.
Artigo em Inglês | MEDLINE | ID: mdl-38273287

RESUMO

BACKGROUND: A positive bronchodilator response has been defined as a 12% increase in the forced expiratory volume in one second (FEV1) or forced vital capacity (FVC) from their respective pre-bronchodilator values, combined with at least a 0.2 L absolute change. Recent recommendations suggested the use of the percent change in FEV1 and FVC relative to their predicted normal values without having applied them in patients with airflow obstruction. The aim of the current study was to compare the two approaches over a wide range of pre-bronchodilator FEV1 and FVC values. METHODS: A retrospective review of consecutive patients undergoing spirometry and bronchodilator testing was completed. The change in FEV1 and FVC with a bronchodilator was expressed relative to the pre-bronchodilator and predicted normal FEV1 and FVC. RESULTS: In 1,040 patients with a non-paradoxical change in FEV1, 19.0% had a ≥ 12% change in FEV1 using their pre-bronchodilator value compared to 5.7% using their predicted normal value. For FVC, the respective values were 12.7% vs. 5.8%. The difference was retained in patients with a ≥ 0.2 L change in FEV1 or FVC. In unobstructed patients, the upper threshold (two standard deviations above the mean) of the bronchodilator response was 14% for FEV1 and 10% for FVC using predicted normal values. CONCLUSIONS: Expressing the percent change in FEV1 and FVC relative to predicted normal values reduces the over-estimation of the bronchodilator response, especially in patients with a very low pre-bronchodilator FEV1, including in those with a ≥ 0.2 L change in FEV1. Irrespective of pre-bronchodilator values, a ≥ 14% change in FEV1 and ≥ 10% change in FVC relative to the predicted normal values could be considered a positive bronchodilator response.


Assuntos
Broncodilatadores , Doença Pulmonar Obstrutiva Crônica , Humanos , Broncodilatadores/farmacologia , Broncodilatadores/uso terapêutico , Doença Pulmonar Obstrutiva Crônica/tratamento farmacológico , Valores de Referência , Pulmão , Capacidade Vital , Espirometria , Volume Expiratório Forçado
2.
Respir Res ; 24(1): 215, 2023 Aug 30.
Artigo em Inglês | MEDLINE | ID: mdl-37649012

RESUMO

RATIONALE: X-ray velocimetry (XV) has been utilized in preclinical models to assess lung motion and regional ventilation, though no studies have compared XV-derived physiologic parameters to measures derived through conventional means. OBJECTIVES: To assess agreement between XV-analysis of fluoroscopic lung images and pitot tube flowmeter measures of ventilation. METHODS: XV- and pitot tube-derived ventilatory parameters were compared during tidal breathing and with bilevel-assisted breathing. Levels of agreement were assessed using the Bland-Altman analysis. Mixed models were used to characterize the association between XV- and pitot tube-derived values and optimize XV-derived values for higher ventilatory volumes. MEASUREMENTS AND MAIN RESULTS: Twenty-four healthy volunteers were assessed during tidal breathing and 11 were reassessed with increased minute ventilation with bilevel-assisted breathing. No clinically significant differences were observed between the two methods for respiratory rate (average Δ: 0.58; 95% limits of agreement: -1.55, 2.71) or duty cycle (average Δ: 0.02; 95% limits of agreement: 0.01, 0.03). Tidal volumes and flow rates measured using XV were lower than those measured using the pitot tube flowmeter, particularly at the higher volume ranges with bilevel-assisted breathing. Under these conditions, a mixed-model based adjustment was applied to the XV-derived values of tidal volume and flow rate to obtain closer agreement with the pitot tube-derived values. CONCLUSION: Radiographically obtained measures of ventilation with XV demonstrate a high degree of correlation with parameters of ventilation. If the accuracy of XV were also confirmed for assessing the regional distribution of ventilation, it would provide information that goes beyond the scope of conventional pulmonary function tests or static radiographic assessments.


Assuntos
Pulmão , Respiração , Adulto , Humanos , Raios X , Radiografia , Volume de Ventilação Pulmonar , Pulmão/diagnóstico por imagem
3.
Lancet Glob Health ; 12(9): e1498-e1505, 2024 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-39151984

RESUMO

BACKGROUND: More than 90% of the morbidity and mortality from chronic respiratory disease occurs in low-income and middle-income countries (LMICs), with substantial economic impact. Preserved ratio impaired spirometry (PRISm) is a prevalent lung function abnormality associated with increased mortality in high-income countries. We aimed to conduct a post-hoc analysis of a cross-sectional study to assess the prevalence of, the risk factors for, and the impact of PRISm in three diverse LMIC settings. METHODS: We recruited a random, age-stratified and sex-stratified sample of the population in semi-urban Bhaktapur, Nepal; urban Lima, Peru; and rural Nakaseke, Uganda. Quality-assured post-bronchodilator spirometry was performed to American Thoracic Society standards and PRISm was defined as a forced expiratory volume in one second (FEV1) of less than 80% predicted with a FEV1/forced vital capacity ratio of 0·70 or more. We used t tests and χ2 analyses to assess the relationships between demographic, biometric, and comorbidity variables with PRISm. Multivariable logistic models with random intercept by site were used to estimate odds ratios (ORs) with 95% CIs. FINDINGS: 10 664 participants were included in the analysis, with a mean (SD) age of 56·3 (11·7) years and an equal distribution by sex. The prevalence of PRISm was 2·5% in Peru, 9·1% in Nepal, and 16·0% in Uganda. In multivariable analysis, younger age (OR for each decile of age 0·87, 95% CI 0·82-0·92) and being female (1·37, 1·18-1·58) were associated with increased odds of having PRISm. Biomass exposure was not consistently associated with PRISm across sites. Individuals with PRISm had impairment in respiratory-related quality of life as measured by the St George's Respiratory Questionnaire (OR by decile 1·18, 95% CI 1·10-1·25). INTERPRETATION: The prevalence of PRISm is heterogeneous across LMIC settings and associated with age, female sex, and biomass exposure, a common exposure in LMICs. A diagnosis of PRISm was associated with worse health status when compared with those with normal lung function. Health systems in LMICs should focus on all spirometric abnormalities as opposed to obstruction alone, given the disease burden, reduced quality of life, and size of the undiagnosed population at risk. FUNDING: Medical Research Council.


Assuntos
Países em Desenvolvimento , Espirometria , Humanos , Estudos Transversais , Feminino , Masculino , Prevalência , Adulto , Pessoa de Meia-Idade , Países em Desenvolvimento/estatística & dados numéricos , Peru/epidemiologia , Nepal/epidemiologia , Uganda/epidemiologia , Volume Expiratório Forçado , Idoso , Fatores de Risco , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA