Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 100
Filtrar
1.
J Nucl Med ; 19(3): 270-5, 1978 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-564941

RESUMO

The limited role of bone scanning in the diagnosis of metabolic bone disease might be considerably improved by accurate quantification of skeletal uptake of the radiopharmaceutical. Using a standard shadow-shield whole-body monitor, we have measured whole-body retention (WBR) of Tc-99m HEDP up to 24 hr in 11 patients with renal osteodystrophy (mean WBR 88.6% at 24 hr); in ten patients with Paget's disease (mean 56.9%); in seven patients with osteomalacia (mean 40.7%); in five patients with primary hyperparathyroidism (mean 50.7%); in four patients with osteoporosis (mean 21.2%); and in 12 normals (mean 19.2%). The osteoporotic group could not be differentiated from the normal group, but the other groups were significantly different from the normal group at 24 hr (p less than 0.002), and each individual rest for the 24-hr WBR of Tc-99m HEDP in these groups lay outside our normal range. This test may, therefore, provide a sensitive means of detecting conditions with increased bone turnover. We obtained measurements of plasma activity of Tc-99m HEDP in these patients up to 24 hr, and 4-hr bone to soft-tissue ratios from bonescan images, but little additional information resulted.


Assuntos
Doenças Ósseas/diagnóstico por imagem , Difosfonatos , Tecnécio , Adolescente , Adulto , Idoso , Distúrbio Mineral e Ósseo na Doença Renal Crônica/diagnóstico por imagem , Humanos , Hiperparatireoidismo/diagnóstico por imagem , Masculino , Pessoa de Meia-Idade , Osteíte Deformante/diagnóstico por imagem , Osteomalacia/diagnóstico por imagem , Osteoporose/diagnóstico por imagem , Cintilografia , Valores de Referência
2.
J Nucl Med ; 20(7): 714-9, 1979 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-541709

RESUMO

The accuracy with which the extent of coronary artery disease can be predicted from stress thallium-201 myocardial images has been assessed in 81 patients with chest pain. Whereas the appearance of the myocardial images was both a sensitive means of detecting coronary artery disease (images abnormal in 43 of 47 patients with abnormal coronary arteriograms) and specific in excluding it (images normal in 31 of 34 patients with normal arteriograms), there was poor correlation between the extent of disease predicted from the Tl-201 images and the findings at arteriography. It is concluded that although stress Tl-201 myocardial imaging is a useful method for the noninvasive diagnosis of coronary artery disease, it cannot be relied upon to predict the number of abnormal vessels.


Assuntos
Doença das Coronárias/diagnóstico por imagem , Coração/diagnóstico por imagem , Esforço Físico , Radioisótopos , Tálio , Adulto , Doença das Coronárias/patologia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Radiografia , Cintilografia
3.
J Nucl Med ; 20(2): 98-101, 1979 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-430202

RESUMO

We have compared bone scintigrams made with Tc-99m-tagged HEDP (1-hydroxyethylidene diphosphonate)and MDP (methylene diphosphonate), the former at 4 hr after injection, the latter at both 2 and 4 hr. In 17 patients with skeletal metastases, there was no significant difference in lesion count or scan quality between the 4-hr images. The tumor-to-bone ratio (T/B) was significantly higher with Tc-HEDP (p less than 0.02). Lesion detection rate and T/B ratios were both lower with Tc-MDP at 2 hr when compared with the 4-hr values for both Tc-HEDP (p less than 0.02, p less than 0.005) and Tc-MDP (p less than 0.02, p less than 0.01). The 4-hr Tc-MDP scan was of significantly higher quality than the 2 hr Tc-MDP scan (p less than 0.01). Although Tc-HEDP produces a higher T/B ratio at 4 hr, the present study does not suggest that either agent is superior in clinical practice.


Assuntos
Neoplasias Ósseas/diagnóstico por imagem , Tecnécio , Adulto , Idoso , Difosfonatos , Estudos de Avaliação como Assunto , Feminino , Humanos , Masculino , Métodos , Pessoa de Meia-Idade , Metástase Neoplásica , Cintilografia
4.
J Nucl Med ; 18(12): 1205-7, 1977 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-606746

RESUMO

Bone scans in three patients showed generalized symmetrical increased uptake of radiopharmaceutical by the skeleton and absent or faint kidney images. It is thought that these appearances may be attributable to excess vitamin D, but other possible contributing factors, including the presence of renal osteodystrophy, are discussed.


Assuntos
Osso e Ossos/diagnóstico por imagem , Vitamina D/efeitos adversos , Adolescente , Criança , Pré-Escolar , Distúrbio Mineral e Ósseo na Doença Renal Crônica/diagnóstico por imagem , Feminino , Humanos , Masculino , Cintilografia
5.
J Nucl Med ; 19(3): 245-8, 1978 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-632900

RESUMO

The presence of eight "metabolic features" was assessed on the bone scintigrams of ten patients with osteomalacia. In all of these bone images, sufficient features were present to strongly suggest a metabolic disorder. There scintiphotos were included in a controlled blind study using 30 normal bone scans and 20 scans of metastatic disease. Nine of the ten metabolic bone images were correctly identified by two independent observers. Skeletal uptake of radiotracer, expressed as bone-to-soft tissue ratio, was significantly higher in the osteomalacic patients than in a group of 80 controls.


Assuntos
Osteomalacia/diagnóstico por imagem , Adolescente , Adulto , Idoso , Difosfonatos , Feminino , Humanos , Masculino , Cintilografia , Tecnécio
6.
J Clin Pathol ; 19(5): 501-3, 1966 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-5919366

RESUMO

Serum uric acid estimations were performed in 106 healthy pregnant women during early, middle, and late pregnancy, using an automated colorimetric method. The mean serum uric acid level was significantly lower during early and middle pregnancy than that of 64 age-matched female controls. The serum uric acid level was not significantly different in late pregnancy from the control group. Studies of the daily urinary urate excretion in 31 pregnant women showed normal urinary urate excretion in early pregnancy and enhanced renal loss of urate in middle and late pregnancy. It appears that the renal clearance of urate in pregnancy is high, especially in the middle period when the serum level is low in spite of the increased production of uric acid by the foetus.


Assuntos
Rim/fisiologia , Gravidez/fisiologia , Ácido Úrico/sangue , Ácido Úrico/urina , Adolescente , Adulto , Colorimetria , Feminino , Humanos , Pessoa de Meia-Idade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA