Pacing Clin Electrophysiol ; 44(4): 614-624, 2021 04.
Artigo em Inglês | MEDLINE | ID: mdl-33624296

RESUMO

BACKGROUND: Cardiac implantable electronic device (CIED)-related perforation is uncommon but potentially lethal. Management typically includes the use of computed tomography (CT) scanning and often involves cardiac surgery. METHODS: Patients presenting to a single referral centre with CIED-related cardiac perforation between 2013 and 2019 were identified. Demographics, diagnostic modalities, the method of lead revision, and 30-day complications were examined. RESULTS: A total of 46 cases were identified; median time from implantation to diagnosis was 14 days (interquartile range = 4-50). Most were females (29/46, 63%), 9/46 (20%) had cancer, 18 patients (39%) used oral anticoagulants, and no patients had prior cardiac surgery. Active fixation was involved in 98% of cases; 9% involved an implantable cardioverter defibrillator lead. Thirty-seven leads perforated the right ventricle (apex: 24) and 9 punctured the right atrium (lateral wall: 5). Abnormal electrical parameters were noted in 95% of interrogated cases. Perforation was visualized in 41% and 6% of cases with chest X-ray (CXR) and transthoracic echocardiography, respectively. CXR revealed a perforation, gross lead displacement, or left-sided pleural effusion in 74% of cases. Pericardial effusion occurred in 26 patients (57%) of whom 11 (24%) developed tamponade, successfully drained percutaneously. Pre-extraction CT scan was performed in 19 patients but was essential in four cases. Transvenous lead revision (TLR) was successfully performed in all cases with original leads repositioned in six patients, without recourse to surgery. Thirty-day mortality and complications were low (0% and 26%, respectively). CONCLUSION: CT scanning provides incremental diagnostic value in a minority of CIED-related perforations. TLR is a safe and effective strategy.


Assuntos
Desfibriladores Implantáveis/efeitos adversos , Traumatismos Cardíacos/diagnóstico por imagem , Traumatismos Cardíacos/cirurgia , Tomografia Computadorizada por Raios X , Idoso , Remoção de Dispositivo , Ecocardiografia , Feminino , Traumatismos Cardíacos/etiologia , Humanos , Masculino , Estudos Prospectivos , Reoperação , Fatores de Risco
2.
Europace ; 20(10): 1647-1656, 2018 10 01.
Artigo em Inglês | MEDLINE | ID: mdl-29528391

RESUMO

Aims: To determine if a software algorithm can use an individualized distance-morphology difference model, built from three initial pacemaps, to prospectively locate the exit site (ES) of ventricular arrhythmias (VA). Methods and results: Consecutive patients undergoing ablation of VA from a single centre were recruited. During mapping, three initial pacing points were collected in the chamber of interest and the navigation algorithm applied to predict the ES, which was corroborated by conventional mapping techniques. Thirty-two patients underwent ES prediction over 35 procedures. Structural heart disease was present in 16 (7 ischaemic cardiomyopathy, 9 non-ischaemic cardiomyopathy), median ejection fraction 45% [Interquartile range (IQR) 26]. The remainder had normal hearts. The navigation algorithm was applied to 46 VA (24 left ventricle, 11 right ventricular outflow tract, 5 left ventricular outflow tract, 4 right ventricle, 2 epicardial) and successfully located the site of best pacemap match in 45 within a median area of 196.5 mm2 (IQR 161.3, range 46.6-1288.2 mm2). Conclusions: In a diverse population of patients with and without structural heart disease, the ES of VA can be accurately and reliably identified to within a clinically useful target area using a simple software navigation algorithm based on pacemapping.


Assuntos
Algoritmos , Técnicas Eletrofisiológicas Cardíacas/métodos , Software , Taquicardia Ventricular/fisiopatologia , Complexos Ventriculares Prematuros/fisiopatologia , Adulto , Idoso , Displasia Arritmogênica Ventricular Direita/complicações , Cardiomiopatias/complicações , Cardiomiopatia Dilatada/complicações , Ablação por Cateter , Cicatriz/complicações , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Isquemia Miocárdica/complicações , Miocardite/complicações , Estudo de Prova de Conceito , Taquicardia Ventricular/etiologia , Taquicardia Ventricular/cirurgia , Complexos Ventriculares Prematuros/etiologia , Complexos Ventriculares Prematuros/cirurgia
3.
Europace ; 19(8): 1317-1321, 2017 Aug 01.
Artigo em Inglês | MEDLINE | ID: mdl-27702870

RESUMO

AIM: The Biosense Webster ThermoCool® SmartTouch® Surround Flow (STSF) catheter is a recently developed ablation catheter incorporating Surround Flow (SF) technology to ensure efficient cooling and force sensing to quantify tissue contact. In our unit, it superseded the ThermoCool® SF catheter from the time of its introduction in May 2015. METHODS AND RESULTS: Procedure-related data were collected prospectively for the first 100 ablation procedures performed in our department using the STSF catheter. From a database of 654 procedures performed in our unit using the SF catheter, we selected one to match each STSF procedure, matching for procedure type, operator experience, patient age, and gender. The groups were well matched for patient age, gender, and procedure type. Procedure duration was similar in both groups (mean 225.5 vs. 221.4 min, IQR 106.5 vs. 91.5, P = 0.55), but fluoroscopy duration was shorter in the STSF group (mean 25.8 vs. 30.0, IQR 19.6 vs. 18.5, P = 0.03). No complication occurred in the STSF group. Complications occurred in two cases in the SF group (one pericardial effusion requiring drainage and one need for permanent pacing). Complete procedural success was achieved in 98 cases in the STSF group and 94 cases in the SF group (P = 0.15). The composite endpoint of procedure failure or acute complication was less common in the STSF group (2 vs. 8, P = 0.05). CONCLUSION: The STSF catheter is safe and effective in treating a range of arrhythmias. Compared with the SF catheter, it shows a trend towards improved safety-efficacy balance.


Assuntos
Arritmias Cardíacas/cirurgia , Cateterismo Cardíaco/instrumentação , Cateteres Cardíacos , Ablação por Cateter/instrumentação , Irrigação Terapêutica/instrumentação , Transdutores de Pressão , Idoso , Arritmias Cardíacas/diagnóstico , Arritmias Cardíacas/fisiopatologia , Cateterismo Cardíaco/efeitos adversos , Ablação por Cateter/efeitos adversos , Bases de Dados Factuais , Desenho de Equipamento , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Duração da Cirurgia , Complicações Pós-Operatórias/etiologia , Estudos Prospectivos , Irrigação Terapêutica/efeitos adversos , Fatores de Tempo , Resultado do Tratamento
5.
J Interv Card Electrophysiol ; 56(2): 205-211, 2019 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-30588568

RESUMO

BACKGROUND: The use of remanufactured single-use devices (SUDs), including cardiac electrophysiology catheters, has become established in the USA and other health care systems but without much published scientific evaluation on the relative safety or efficacy of these devices. In the United Kingdom (UK), the use of remanufactured SUDs has not been routine. We performed a structured evaluation of the safety and efficacy of a remanufactured circular mapping catheter (Stryker® remanufactured Lasso NAV 2515) during its introduction in our centre. METHODS: We prospectively evaluated the performance of a remanufactured circular mapping catheter in 100 consecutive patients undergoing an AF ablation. Operator feedback was obtained, assessing the device appearance, ease of use and function. As an indirect measurement of efficacy, acute procedure metrics were compared to those in 100 propensity-matched cases performed by the same operators using a new device. Cost savings were calculated. RESULTS: No complication occurred in association with the remanufactured device. There was one reported failure of device malfunction-the flexion-extension mechanism of a remanufactured catheter and none in the matched-control group. There was satisfactory communication with the electro-anatomic mapping system. Ease of use of the remanufactured catheter was reported to be similar to a newly manufactured device. Procedural duration was similar with remanufactured devices and matched controls. With 100 cases using the remanufactured device, cost savings amounted to £30,444. CONCLUSIONS: The use of remanufactured circular mapping catheters is safe, efficient and reliable. Widespread use of remanufactured SUDs offers the possibility of significant economic benefit.


Assuntos
Fibrilação Atrial/cirurgia , Cateteres Cardíacos , Ablação por Cateter/instrumentação , Reutilização de Equipamento , Adulto , Idoso , Idoso de 80 Anos ou mais , Desenho de Equipamento , Segurança de Equipamentos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Reino Unido
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA