Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
1.
Liver Transpl ; 25(11): 1682-1689, 2019 11.
Artigo em Inglês | MEDLINE | ID: mdl-31119833

RESUMO

Intracardiac thrombus (ICT) is an intraoperative complication with high mortality that occurs during orthotopic liver transplantation (OLT). Patients with end-stage liver disease have compromised coagulation pathways, and when combined with stressors of surgery, thrombi can form. However, it is unknown which patients are most likely to develop ICT. We performed a retrospective cohort study of all OLT patients at our hospital from 2010 to 2017 to identify risk factors for ICT. An analysis was performed with conventional bivariate tests and logistic regression. The incidence of ICT during OLT was 4.2% (22/528) with a 45.5% (10/22) mortality. Patients who developed ICT had higher physiologic Model for End-Stage Liver Disease scores at the time of transplant (25.1 versus 32.4; P = 0.004), received grafts from donors with a higher body mass index (28.1 versus 32.2 kg/m2 ; P = 0.007), and had longer intraoperative warm ischemia times (53.1 versus 67.5 minutes; P = 0.001). The odds of developing ICT were significantly lower after administration of intravenous (IV) heparin prior to inferior vena cava (IVC) clamping compared with no administration of heparin (odds ratio, 0.25; 95% confidence interval, 0.08-0.75; P = 0.01). In conclusion, the incidence of ICT at our institution is higher than previously reported, which may be explained by our routine use of transesophageal echocardiography. Although many factors associated with ICT in this study are nonmodifiable, administration of IV heparin prior to IVC cross-clamping is modifiable and was found to be protective. Further studies will be needed to confirm findings and ultimately aid in preventing these lethal events.


Assuntos
Vasos Coronários/diagnóstico por imagem , Doença Hepática Terminal/cirurgia , Complicações Intraoperatórias/epidemiologia , Transplante de Fígado/efeitos adversos , Trombose/epidemiologia , Administração Intravenosa/estatística & dados numéricos , Idoso , Coagulação Sanguínea/fisiologia , Ecocardiografia Transesofagiana , Doença Hepática Terminal/complicações , Doença Hepática Terminal/mortalidade , Doença Hepática Terminal/fisiopatologia , Feminino , Heparina/administração & dosagem , Mortalidade Hospitalar , Humanos , Incidência , Cuidados Intraoperatórios/métodos , Cuidados Intraoperatórios/estatística & dados numéricos , Complicações Intraoperatórias/diagnóstico , Complicações Intraoperatórias/etiologia , Complicações Intraoperatórias/prevenção & controle , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Fatores de Risco , Trombose/diagnóstico , Trombose/etiologia , Trombose/prevenção & controle
3.
4.
Saudi J Anaesth ; 13(3): 249-252, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-31333374

RESUMO

Medication shortages are a clinical reality that force changes in practice patterns leading to unintended consequences. Potential solutions to any drug shortage require a thoughtful, multidisciplinary and often creative approach. Here, we report a case of unintentional epinephrine overdose leading to an unstable cardiac arrhythmia and our subsequent development of a visual cue system to prevent future errors. A 56-year-old man with a history of rectal adenocarcinoma presented for low anterior resection and creation of diverting loop ileostomy. Epidural placement was requested by the surgical team, and following administration of a second test dose (created by the physician), the patient experienced supraventricular tachycardia with heart rates of 200-210 BPM for approximately 2 minutes. This rhythm then converted to atrial fibrillation with rapid ventricular response with heart rate of 150-170 BPM. The patient was stabilized after cardioversion. Later evaluation of medication administration revealed that the second epidural test dose inadvertently contained 100 mcg epinephrine instead of the intended 10 mcg dose. The test dose had to be created because the original ampule with the kit had been utilized. Since this time, our kits have no test dose, and this shortage is concerning for increased provider error. We suggest a novel visual cue system that may prevent unintentional epinephrine overdoses in the setting of regional anesthesia.

5.
Case Rep Anesthesiol ; 2019: 1246256, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-31934454

RESUMO

The demand for liver transplants in the United States far exceeds the supply of organs. As need has increased, so has use of living donors. Coagulopathy and various side effects often preclude the use of neuraxial regional techniques and opioids for postoperative analgesia in patients with large "J" incisions. Here, we present a 25-year-old male undergoing a living donor hepatectomy who received quadratus lumborum catheters placed percutaneously after closure of incision and prior to emergence to provide excellent analgesia and a viable opioid-sparing approach. Quadratus lumborum catheters are a safe option for a multimodal, opioid-sparing approach to analgesia.

6.
J Cyst Fibros ; 9(4): 284-7, 2010 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-20471332

RESUMO

BACKGROUND: With the rapid implementation of cystic fibrosis (CF) newborn screening (NBS), quality improvement (QI) has become essential to identify and prevent errors. Using Process Failure Modes and Effects Analysis (PFMEA), we adapted this method to determine if it could be applied to discover and rank high priority QI opportunities. METHODS: Site visits to three programmes were conducted, and PFMEA exercises were accomplished in Colorado, Massachusetts and Wisconsin with 23 experienced professionals. During each of these comprehensive sessions, participants identified and ranked potential failures based on severity, occurrence and detection to calculate risk priority number (RPN) values. RESULTS: A total of 96 failure modes were generated and ranked in a list of the 20 riskiest problems that show no significant discordances by site, although there were differences by profession of the rater, particularly nurses. CONCLUSIONS: Our results illustrate that the PFMEA method applies well to CF NBS and that steps requiring communication and information transfer are perceived to be the highest risks. The number of identified failures makes and their potential impact demonstrate considerable overall risk and a need for ongoing QI.


Assuntos
Fibrose Cística/diagnóstico , Erros Médicos/estatística & dados numéricos , Triagem Neonatal/métodos , Garantia da Qualidade dos Cuidados de Saúde , Colorado , Humanos , Recém-Nascido , Massachusetts , Erros Médicos/prevenção & controle , Indicadores de Qualidade em Assistência à Saúde , Wisconsin
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA