Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 26
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Eur Heart J Suppl ; 25(Suppl C): C38-C43, 2023 May.
Artigo em Inglês | MEDLINE | ID: mdl-37125303

RESUMO

Since the first description of Brugada syndrome (BrS), several studies were carried out aimed at diagnosis, arrhythmic risk stratification, and available strategies for sudden death prevention. In high-risk patients, the use of an implantable cardiac defibrillator was an evident option since the first description of the syndrome. Nevertheless, this strategy, while proven, as expected, to be effective in sudden death prevention, does not prevent arrhythmias and may not be an adequate or accepted solution for all patients. The need of a non-pharmacological therapy as a potential solution based on the electrophysiological mechanisms underlying the syndrome, led to search for substrate as target for catheter ablation. Advances in the tools, technology, and technical approach enabled to launch studies aimed at mapping the epicardium of patients with BrS in order to identify and ablate the substrate. As described in previous work and in our experience, an anatomically identifiable electrical substrate, which correspond to the typical ECG, is the ablation target. Complete substrate is better identified in a larger area with sodium-channel-blockers. Ablation of all abnormal electrical potentials is able to normalize the ECG and prevent arrhythmias induction. Encouraging preliminary data, if confirmed by longer follow-up and by multicentre randomized study, could change the whole therapeutic management in BrS patients.

2.
Pacing Clin Electrophysiol ; 44(6): 1102-1114, 2021 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-33825206

RESUMO

PURPOSE: Ventricular tachycardia (VT) ablation is a complex procedure that requires remarkable catheter manipulation skill, great mapping accuracy and catheter stability, and can expose patients to serious complications. Magnetic navigation system (RMN)-guided ablation and contact force-sensing (CFS) catheters have the potential to overcome these obstacles. We performed a systematic review and updated meta-analysis of all available studies evaluating the outcomes of VT ablation by using RMN-guided compared to manual navigation (MAN)-guided, with and without CFS catheters. METHODS: MEDLINE/PubMed, Cochrane, and Google Scholar were searched for randomized controlled trials (RCT) or observational studies with multivariate adjustment comparing RMN-guided versus MAN-guided VT ablation. RESULTS: Thirteen studies enrolling 1348 patients (656 RMN-guided vs. 692 MAN-guided) were included. CFS catheter were used in 14% of MAN-guided patients. In comparison to MAN-guided and CFS-guided, RMN-guided VT ablation was associated with a significant higher acute ablation success (OR 2.32, 1.66-3.23 and OR 2.91, 1.29-6.53, respectively) but similar results in term of long-term VT recurrence (OR 0.75, 0.56-1.01 and OR 0.79, 0.27-2.36, respectively). RMN-guided showed a better safety profile (for all complications, OR 0.52, 0.34-0.81) and allowed a significant x-ray reduction compared to MAN-guided (OR 0.21, 0.14-0.32) and CFS-guided VT ablation (OR 0.23, 0.11-0.52, all 95% CI). CONCLUSIONS: RMN-guided was superior to MAN-guided and CFS-guided VT ablation in term of acute ablation success, all complications endpoint, and reduction of fluoroscopy exposure, but did not reduce long-term VT recurrence. Large prospective multicenter randomized trials are needed to confirm these findings.


Assuntos
Ablação por Cateter/métodos , Magnetismo , Cirurgia Assistida por Computador/métodos , Taquicardia Ventricular/fisiopatologia , Taquicardia Ventricular/terapia , Humanos
3.
Pacing Clin Electrophysiol ; 44(6): 995-1003, 2021 06.
Artigo em Inglês | MEDLINE | ID: mdl-33908052

RESUMO

BACKGROUND: During the COVID-19 pandemic in-person visits for patients with cardiac implantable electronic devices should be replaced by remote monitoring (RM), in order to prevent viral transmission. A direct home-delivery service of the RM communicator has been implemented at 49 Italian arrhythmia centers. METHODS: According to individual patient preference or the organizational decision of the center, patients were assigned to the home-delivery group or the standard in-clinic delivery group. In the former case, patients received telephone training on the activation process and use of the communicator. In June 2020, the centers were asked to reply to an ad hoc questionnaire to describe and evaluate their experience in the previous 3 months. RESULTS: RM was activated in 1324 patients: 821 (62%) received the communicator at home and the communicator was activated remotely. Activation required one additional call in 49% of cases, and the median time needed to complete the activation process was 15 min [25th-75th percentile: 10-20]. 753 (92%) patients were able to complete the correct activation of the system. At the time when the questionnaire was completed, 743 (90%) communicators were regularly transmitting data. The service was generally deemed useful (96% of respondents) in facilitating the activation of RM during the COVID-19 pandemic and possibly beyond. CONCLUSIONS: Home delivery of the communicator proved to be a successful approach to system activation, and received positive feedback from clinicians. The increased use of a RM protocol will reduce risks for both providers and patients, while maintaining high-quality care.


Assuntos
Arritmias Cardíacas/terapia , COVID-19/epidemiologia , Desfibriladores Implantáveis , Serviços de Assistência Domiciliar , Distanciamento Físico , Pneumonia Viral/epidemiologia , Tecnologia de Sensoriamento Remoto/instrumentação , Feminino , Humanos , Incidência , Itália , Masculino , Marca-Passo Artificial , Pandemias , Pneumonia Viral/virologia , SARS-CoV-2
4.
Surg Technol Int ; 38: 451-454, 2021 05 20.
Artigo em Inglês | MEDLINE | ID: mdl-33755942

RESUMO

This report presents the authors' experience with surgical wound-healing using a negative-pressure wound therapy (NPWT) device in a population of oncological orthopedic patients. Two groups of 26 oncological patients each underwent surgical excision. After surgery, the control group received standard dressings and the closed incisional NPWT (ciNPWT) group was treated with a ciNPWT system on the sutured wound area for 14 days. As a primary endpoint, the percentage of post-surgery wound-site complications using ciNPWT devices was compared to that with standard patch dressings. Overall, 30.7% of the control group and 7.7% of the ciNPWT group manifested wound-site complications within 2 weeks after surgery. As a secondary endpoint, final wound healing was compared between the groups: delayed wound healing was observed in 4 (15.4%) patients in the control group and in none (0%) of those in the ciNPWT group. Finally, the length of stay (LOS) was 6.3 days in the control group and 5.1 days in the ciNPWT group. These results suggest that the ciNPWT device could be beneficial in minimizing the incidence of short-term surgical-site complications and decreasing length of stay in high-risk patients, such as those undergoing oncological orthopedic surgery.


Assuntos
Tratamento de Ferimentos com Pressão Negativa , Procedimentos Ortopédicos , Bandagens , Humanos , Procedimentos Ortopédicos/efeitos adversos , Infecção da Ferida Cirúrgica , Cicatrização
5.
Surg Technol Int ; 38: 387-392, 2021 05 20.
Artigo em Inglês | MEDLINE | ID: mdl-33624831

RESUMO

Meniscal injuries are a common challenge in orthopaedic surgery. Depending on their location and the patient's age and functional needs, they can be treated either conservatively or surgically. A surgical approach can consist of arthroscopic meniscectomy or meniscal suture. The latter is the treatment of choice in case of lesions involving the red-red or red-white areas of the meniscus, especially for young high-demanding patients. We report here our experience with the repair of longitudinal meniscal tears using the all-inside technique with the Fast-Fix™ 360 Meniscal Repair System (Smith & Nephew Endoscopy, Andover, MA). We retrospectively evaluated 20 consecutive cases of longitudinal meniscal tears. In 4 cases, concomitant ACL rupture was diagnosed and treated alongside the meniscal repair. All patients underwent periodic clinical evaluations. At the latest check-up, their functional outcomes were rated according to the Tegner-Lysholm Knee and KOOS scoring scales. The mean Tegner-Lysholm Knee score was 84.85 (44-100) and the mean KOOS score was 88.58. No failure or major complications were observed. Furthermore, a negative statistical association was observed between age at surgery and the post-operative Tegner-Lysholm Knee score (coef. = -1.01189 [-1.942073,-0.0817063], p = 0.035). This relation, independent of gender, meniscus involved, eventual associated ACL reconstruction, and chondral injury, suggests that functional outcomes worsen with increasing patient age. Our results suggest that the arthroscopic all-inside suture is both safe and effective in cases of longitudinal meniscal tear, considering the good post-operative functionality and low rates of local complications and surgical failures.


Assuntos
Lesões do Menisco Tibial , Artroscopia , Humanos , Meniscos Tibiais/cirurgia , Estudos Retrospectivos , Técnicas de Sutura , Lesões do Menisco Tibial/cirurgia
6.
Surg Technol Int ; 36: 341-346, 2020 May 28.
Artigo em Inglês | MEDLINE | ID: mdl-32190898

RESUMO

En bloc scapulectomy with covering muscles was historically considered the only procedure available for surgical treatment of bone and soft tissue tumors of the scapula. When possible, reconstruction with scapular allograft is the gold standard, and gives satisfactory functional, cosmetic, and oncological outcomes. While good results have recently been reported with 3D-printed prostheses for reconstruction of bone loss, there is little information available in the medical literature regarding scapula reconstruction with a 3D-printed prosthesis. Between 2016 and 2018, we performed four scapular resections (two total and two involving the superior 1/3) followed by reconstruction with a 3D-printed prosthesis made of a porous titanium alloy (Ti-6Al-4V, diameter between 100 and 400 mm), using computer-aided design (CAD) and patient-specific implants (PSI) with previously acquired CT-MR fusion images. At 2 years follow-up, the patients with partial scapulectomy had an MSTS score of 76%, no local or systemic recurrence, good clinical results and no pain. At 1 year 6 months follow-up, the patients with total scapulectomy had an MSTS score of 46%, no local or systemic recurrence, fair clinical results and no pain. Thus, custom-made 3D-printed prostheses appear to be valuable in orthopedic surgery. However, a larger cohort and longer-term analysis are needed to evaluate the scapular 3D-printed prosthesis as a reliable reconstruction technique.


Assuntos
Procedimentos Ortopédicos , Escápula , Humanos , Impressão Tridimensional , Próteses e Implantes , Desenho de Prótese , Implantação de Prótese
7.
Pacing Clin Electrophysiol ; 41(5): 450-458, 2018 05.
Artigo em Inglês | MEDLINE | ID: mdl-29405314

RESUMO

RATIONALE: Pulmonary vein isolation (PVI) is the method of choice for the treatment of drug-resistant atrial fibrillation (AF). However, arrhythmia recurrences are frequent due to suboptimal lesions formation and pulmonary vein reconnection. Contact force (CF)- and remote magnetic navigation (RMN)-guided catheters are both capable of improving contact and energy transfer to the tissue, possibly improving PVI outcome. OBJECTIVE: The objective of our study was to compare CF- and RMN-guided PVI in patients with paroxysmal AF in terms of surrogate parameters of the dimension and quality of the lesions. METHODS AND RESULTS: Between March 2014 and March 2016, 44 patients affected by paroxysmal AF underwent a circumferential PVI procedure, 22 with a CF catheter and 22 with a RMN catheter. Signals were recorded before and after 30 seconds of radiofrequency point-by-point delivery. For each location, signal energy attenuation and impedance drop were evaluated as lesion dimension surrogates and signal fragmentation and shrinkage were estimated as lesion quality surrogates. Statistical analysis shows that CF catheter achieves higher attenuation and impedance drop than RMN-guided catheter, which instead performs better in terms of shrinkage and fragmentation. There were no differences in terms of PVI rate and sinus rhythm maintenance 1 year after the procedure (77.2% in both groups). CONCLUSIONS: CF-guided catheters produce lesions that are larger but less homogeneous than those produced by RMN-guided catheters in terms of surrogate parameters. These two features could possibly offset each other, resulting in identical acute and long-term outcomes.


Assuntos
Fibrilação Atrial/cirurgia , Cateteres Cardíacos , Magnetismo , Veias Pulmonares/cirurgia , Ablação por Radiofrequência/instrumentação , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Recidiva , Resultado do Tratamento
8.
Pacing Clin Electrophysiol ; 40(2): 199-212, 2017 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-28054377

RESUMO

BACKGROUND: This meta-analysis aims to assess the impact of a voltage-guided substrate modification by targeting low-voltage area (LVA) in addition to pulmonary vein isolation (PVI) in patients undergoing catheter ablation for atrial fibrillation (AF). METHODS: MEDLINE/PubMed, Cochrane Library, and references reporting AF ablation and "voltage* OR substrate* OR fibrosis OR fibrotic area*" were screened and studies included if matching inclusion and exclusion criteria. RESULTS: Six studies were included. Patients enrolled were 885 (517 in the study group and 368 in the control group). Median age was 60 years; 92% had nonparoxysmal AF. At a mean follow-up of 17 months, 70% of patients in the study group vs. 43% in the control group were free from AF/atrial tachycardia (AT) recurrences (odds ratio [OR] = 3.41, 95% confidence interval [CI] 2.22-5.24). LVA ablation in addition to PVI was more effective than PVI alone and PVI + conventional wide empirical ablation (70% vs. 43%, OR = 3.41, 95% CI 2.22-5.24), without increasing the adverse event rate (2.5% vs. 6%, OR = 0.43, 95% CI 0.15-1.26). Compared to PVI + conventional wide empirical ablation, LVA ablation reduced the occurrence of postablation AT (14% vs. 46%, OR = 0.16, 95% CI 0.07-0.37), procedure time (176 min vs. 220 min, OR = 0.36, 95% CI 0.24-0.56), fluoroscopy time (25 min vs. 31 min, OR = 0.22, 95% CI 0.12-0.39), and radiofrequency time (55 min vs. 90 min, OR = 0.49, 95% CI 0.27-0.90). CONCLUSIONS: A voltage-guided substrate modification by targeting LVA in addition to PVI is more effective, safer, and holds a lower proarrhythmic potential than conventional ablation approaches. Further randomized studies are necessary to confirm these findings.


Assuntos
Fibrilação Atrial/epidemiologia , Fibrilação Atrial/cirurgia , Mapeamento Potencial de Superfície Corporal/estatística & dados numéricos , Ablação por Cateter/estatística & dados numéricos , Complicações Pós-Operatórias/epidemiologia , Cirurgia Assistida por Computador/estatística & dados numéricos , Fibrilação Atrial/diagnóstico , Mapeamento Potencial de Superfície Corporal/métodos , Ablação por Cateter/métodos , Feminino , Átrios do Coração/cirurgia , Humanos , Masculino , Pessoa de Meia-Idade , Duração da Cirurgia , Complicações Pós-Operatórias/prevenção & controle , Prevalência , Fatores de Risco , Cirurgia Assistida por Computador/métodos , Resultado do Tratamento
9.
Pacing Clin Electrophysiol ; 39(8): 814-21, 2016 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-27196672

RESUMO

BACKGROUND: Anisotropy in conduction velocity (CV) is a key substrate abnormality influencing atrial arrhythmias. In skeletal muscle fibers, CV and frequency content of the surface electromyogram signal are directly related. We hypothesized that in human atria the frequency content of the bipolar signal, recorded on the endocardial surface, is directly related to the local CV. METHODS: In 15 patients submitted to ablation of supraventricular arrhythmias, incremental pacing was performed through an octapolar catheter inserted into the coronary sinus (CS), alternatively from both extremities in two different sequences: CS bipole 1-2 as the pacing site and CS bipole 7-8 as the detection site in the first, and vice versa in the second. The pacing cycle length (PCL) was stepwise decreased from 600 ms to 500 ms, 400 ms, 300 ms, until 250 ms. Estimation of the CV was performed as the ratio between the distance traveled by the propagating pulse and the propagation time. The frequency distribution of the signal energy was estimated using the fast Fourier transform, and the characteristic frequency (CF) was estimated as the barycenter of the frequency spectrum. RESULTS: A total of 2,496 bipolar signals were analyzed; CV and CF were estimated and compared. The single patient and group data analysis showed a significant direct correlation between CV and CF of the local bipolar signal. CONCLUSIONS: Comparing the degree of spectral compression among signals registered in different points of the endocardial cardiac surface in response to decreasing PCL enables to map local differences in CV, a useful arrhythmogenic substrate index.


Assuntos
Mapeamento Potencial de Superfície Corporal/métodos , Átrios do Coração/fisiopatologia , Sistema de Condução Cardíaco/fisiopatologia , Condução Nervosa , Taquicardia por Reentrada no Nó Atrioventricular/fisiopatologia , Síndrome de Wolff-Parkinson-White/fisiopatologia , Adulto , Idoso , Diagnóstico por Computador/métodos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Taquicardia por Reentrada no Nó Atrioventricular/diagnóstico , Síndrome de Wolff-Parkinson-White/diagnóstico
10.
JACC Adv ; 3(5): 100899, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38939638

RESUMO

Background: The prognostic impact of catheter ablation (CA) of atrial fibrillation (AF) in hypertrophic cardiomyopathy (HCM) patients has not yet been satisfactorily elucidated. Objectives: The aim of the study was to assess the impact of CA of AF on clinical outcomes in a large cohort of HCM patients. Methods: In this retrospective multicenter study, 555 HCM patients with AF were enrolled, 140 undergoing CA and 415 receiving medical therapy. 1:1 propensity score matching led to the inclusion of 226 patients (113 medical group, 113 intervention group) in the final analysis. The primary outcome was a composite of all-cause mortality, heart transplant and acute heart failure exacerbations. Secondary outcomes included AF recurrence and transition to permanent AF. Additionally, an inverse probability weighted (IPW) model was examined. Results: At propensity score matching analysis, after a median follow-up of 58.1 months, the primary endpoint occurred in 29 (25.7%) patients in intervention group vs 42 (37.2%) in medical group (P = 0.9). Thromboembolic strokes and major arrhythmic events in intervention vs medical group were 9.7% vs 7.1% (P = 0.144) and 4.4 vs 8.0% (P = 0.779), respectively. Fewer patients in intervention vs medical group experienced AF recurrences (63.7% vs 84.1%, P = 0.001) and transition to permanent AF pattern (20.4% vs 33.6%, P = 0.026). IPW analysis showed consistent results. Severe complications related to CA were uncommon (0.7%). Conclusions: After 5 years of follow-up, CA did not improve major adverse cardiac outcomes in a large cohort of patients with HCM and AF. Nevertheless, CA seems to facilitate the maintenance of sinus rhythm and slow the progression to permanent AF, without significant safety concerns.

11.
J Cardiovasc Electrophysiol ; 24(1): 24-32, 2013 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-23140485

RESUMO

INTRODUCTION: Long-term outcome of AF ablation in patients with impaired LVEF is unknown. The aim of this study is to evaluate sinus rhythm (SR) maintenance, clinical status, and echocardiographic parameters over a long-term period following atrial fibrillation (AF) transcatheter ablation in patients with left ventricular ejection fraction (LVEF) <50%. METHODS AND RESULTS: A total of 196 patients (87.2% males, age 60.5 ± 10.2 years) with LVEF <50% underwent radiofrequency transcatheter ablation for paroxysmal (22.4%) or persistent (77.6%) AF. Patients were followed up for 46.2 (16.4-63.5) months regarding AF recurrences, functional class, and echocardiographic parameters. All patients underwent pulmonary vein isolation, while 167 (85.2%) required additional atrial lesions. Eleven (5.6%) patients suffered procedural complications. During follow-up, 58 (29.6%) patients required repeated ablations. At the follow-up end, 15 (7.7%) patients died, while 74 (37.8%) documented at least one episode of AF, atrial flutter, or atrial ectopic tachycardia. Eighty-three (47.2%) patients maintained antiarrhythmic drugs. During follow-up, NYHA class improved by at least one class more frequently among patients maintaining SR compared to those experiencing relapses (70.6% vs 47.9%, P = 0.003). LVEF showed a broader relative increase in patients maintaining SR (32.7% vs 21.4%; P = 0.047) and mitral regurgitation grading significantly decreased (P <0.001) only within these patients. At multivariable analysis SR maintenance emerged as an independent predictor (odds ratio 4.26, 95% CI 1.69-10.74, P = 0.002) of long-term clinical improvement (reduction in NYHA class ≥ 1 and relative increase in LVEF ≥ 10%). CONCLUSIONS: Although not substantially worse than in patients with preserved LVEF, AF ablation in patients with impaired LVEF is affected by high long-term recurrence rate. Among these patients SR maintenance is associated with greater clinical improvement.


Assuntos
Fibrilação Atrial/epidemiologia , Fibrilação Atrial/cirurgia , Cateterismo Cardíaco/estatística & dados numéricos , Ablação por Cateter/estatística & dados numéricos , Disfunção Ventricular Esquerda/epidemiologia , Disfunção Ventricular Esquerda/cirurgia , Comorbidade , Feminino , Humanos , Incidência , Itália/epidemiologia , Estudos Longitudinais , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Fatores de Risco , Volume Sistólico , Resultado do Tratamento
12.
Front Cardiovasc Med ; 10: 1224924, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37876773

RESUMO

Introduction: Atrial fibrillation (AF) is the main cause of cardioembolic stroke. In high-bleeding-risk patients, long-life anticoagulation therapy is not permitted, and left atrial appendage (LAA) closure may be considered. LAA is also a critical substrate for AF. Epicardial LAA occlusion has several advantages: LAA ligation results in a favorable electrical and structural atrial remodeling, which decreases AF recurrence. Endocardial ablation alone is not efficient for all patients, and new evidence shows better outcomes in patients affected by persistent AF after a combined hybrid endo-epicardial ablation. Considering the synergic potential of these techniques, in this case series, they were both combined in a single procedure. Methods and results: We describe the treatment of 5 patients referred for refractory AF ablation and LAA closure. All patients had high thrombotic and previous major hemorrhage, with relative contraindication to life-long therapy with anticoagulation. A combined procedure of LAA ligation and endo-epicardial ablation was scheduled with short-term anticoagulation. LAA closure was performed with an epicardial approach using the LARIAT system. Then, LA mapping and ablation were performed, endocardially and then epicardially.All procedures were concluded without complications.At follow-up, in all patients, transesophageal echocardiography showed the complete occlusion of the LAA; therefore, anticoagulation therapy was interrupted. All patients were asymptomatic, and in the sinus rhythm, no hemorrhage or ischemic events occurred. Conclusion: The combination of percutaneous LAA ligation and endo-epicardial ablation was revealed to be feasible and safe and might represent a new approach for the treatment of refractory AF in patients with indication of LAA occlusion.

13.
J Interv Card Electrophysiol ; 66(1): 179-192, 2023 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-34436722

RESUMO

PURPOSE: Data regarding the age-specific outcomes of VT ablation in patients with structural heart disease (SHD) are scarce. We performed a systematic review and meta-analysis to evaluate the outcomes of VT ablation in elderly vs. younger patients with SHD. METHODS: MEDLINE/PubMed, Cochrane, and Google Scholar and references comparing VT ablation in elderly vs. younger patients were screened and studies included if matching inclusion and exclusion criteria. RESULTS: Five retrospective studies enrolling 2778 SHD patients (868 elderly vs. 1910 younger) were included. Compared to younger subjects, the elderly showed similar results in terms of acute ablation success (OR 0.78, 95% CI 0.54-1.13, p = 0.189) and minor complications (OR 1.74, 95% CI 0.74-4.09, p = 0.205), a trend toward a higher risk of major complications (OR 2.30, 95% CI 0.83-6.40, p = 0.110) and significantly higher rates of all complications (OR 2.67, 95% CI 1.51-4.71, p = 0.001) and periprocedural mortality (OR 1.93, 95% CI 1.24-3.01, p = 0.004). At a mean follow-up of 18 months, elderly patients showed similar long-term VT recurrence rate (OR 1.02, 95% CI 0.85-1.22, p = 0.861) and higher all-cause mortality (OR 2.00, 95% CI 1.40-2.86, p < 0.001). In elderly patients, urgent VT ablation is associated with higher risk of major complications (beta = 0.06, p < 0.001) and periprocedural mortality (beta = 0.03, p = 0.029), while advanced age is associated with higher risk of major complications (beta = 0.29 with p = 0.009) and all complications + periprocedural mortality (beta = 0.17 with p = 0.037). CONCLUSIONS: Compared to younger patients, VT ablation in elderly showed similar results in terms of acute ablation success and long-term VT recurrence rate with a significantly higher risk of all complications, periprocedural mortality, and long-term mortality, especially when the procedure is performed urgently and in the most aged patients. Large prospective multicenter randomized trials are required to confirm these findings.


Assuntos
Ablação por Cateter , Cardiopatias , Taquicardia Ventricular , Idoso , Humanos , Estudos Prospectivos , Estudos Retrospectivos , Ablação por Cateter/métodos , Resultado do Tratamento , Recidiva , Estudos Multicêntricos como Assunto
14.
Minerva Cardiol Angiol ; 71(1): 91-99, 2023 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-35080355

RESUMO

BACKGROUND: Catheter ablation (CA) of atrial fibrillation (AF) is used routinely to establish rhythm control. There is mounting evidence that CA procedures should be performed during continuous oral anticoagulation and direct oral anticoagulants (DOACs) are considered the first anticoagulation strategy. Few real-life data are now available and even less in the Italian panorama. METHODS: IRIS is an Italian multicenter, non-interventional, prospective study which will be enrolled consecutive AF patients eligible for CA and treated with Rivaroxaban; patients in treatment with Rivaroxaban proceeded directly to CA while Rivaroxaban-naive patients were scheduled for CA after 4 weeks of uninterrupted anticoagulation unless the exclusion of atrial thrombi. Rivaroxaban was uninterrupted or shortly uninterrupted (<24 hours) prior CA, in line with routinely practice of each operator. Patients will be followed on continuous anticoagulation for 1 month after the ablation. The primary efficacy outcome is the cumulative incidence of all-cause death and systemic embolism while the primary safety outcome is the incidence of major bleeding events. The secondary outcomes are represented by non-major bleeding events. All events must be occurred within the first 30 days after the procedure. RESULTS: Two hundred fifty patients are expected to be enrolled and the study is estimated to be completed by the end of 2022. Up to now 56 patients have been enrolled. CONCLUSIONS: This study is the first large Italian prospective study on the management of Rivaroxaban in patients undergoing CA of AF. It aims to depict a comprehensive view of anticoagulation strategy prior CA in several Italian electrophysiology labs.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Humanos , Rivaroxabana/efeitos adversos , Fibrilação Atrial/tratamento farmacológico , Fibrilação Atrial/cirurgia , Estudos Prospectivos , Inibidores do Fator Xa/efeitos adversos , Resultado do Tratamento , Hemorragia/induzido quimicamente , Hemorragia/cirurgia , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Sistema de Registros
15.
G Ital Cardiol (Rome) ; 23(7): 553-561, 2022 Jul.
Artigo em Italiano | MEDLINE | ID: mdl-35771021

RESUMO

BACKGROUND: Despite the availability of effective lipid-lowering drugs, only few high-risk patients attain their LDL cholesterol (LDL-C) guideline-recommended risk-based goal because of underprescription of combination therapy. We present an 18-month experience with variation of prescription protocols after publication of the 2019 ESC/EAS guidelines for the management of dyslipidemias. METHODS: Overall, 621 consecutive patients hospitalized for acute coronary syndrome at Mauriziano Hospital in Turin, Italy, between January 2020 and June 2021 were enrolled. Lipid-lowering therapy recommended at discharge was registered to evaluate how many patients received statin monotherapy, statin plus ezetimibe combination or triple therapy with high-intensity statin plus ezetimibe and proprotein convertase subtilisin/kexin type 9 inhibitor (PCSK9i). At 6-month follow-up, the reduction in LDL-C, adverse events, compliance and cardiovascular recurrences was analyzed. RESULTS: Of 621 patients enrolled, 7 died during hospitalization. During the entire study period, 33% of patients received statin monotherapy, 50% were discharged on statin-ezetimibe combination, and PCSK9i (evolocumab) was prescribed to 17% of patients. Between April 2020 and June 2021, when new recommendations were introduced into clinical practice, 20% of patients received evolocumab, 56% combination therapy and only 24% were discharged on statin monotherapy. At the beginning of observation, evolocumab was prescribed to 3% of patients hospitalized for acute coronary syndrome, while at the end of the study period 27% of patients were discharged on PCSK9i, with an increase of the prescription rate by 759%; in the same period, prescription of statin monotherapy decreased by 75%. At 6-month follow-up, LDL-C reduction was 77% in patients treated with PCSK9i vs 48% in patients taking statin-ezetimibe combination therapy (p<0.001). All patients on evolocumab reached the guideline-directed goals and a low rate of adverse events was reported, mainly represented by local injection site reactions. Six patients experienced acute coronary syndrome recurrence; only one of them was treated with evolocumab. CONCLUSION: Prescription of intensive lipid-lowering therapy after acute coronary syndrome, eventually with introduction of PCSK9i during hospitalization or at discharge, leads to attainment of guideline-recommended goals for all patients, with a low incidence of adverse events and optimal compliance.


Assuntos
Síndrome Coronariana Aguda , Anticolesterolemiantes , Dislipidemias , Inibidores de Hidroximetilglutaril-CoA Redutases , Síndrome Coronariana Aguda/tratamento farmacológico , Anticolesterolemiantes/uso terapêutico , LDL-Colesterol , Dislipidemias/tratamento farmacológico , Ezetimiba/uso terapêutico , Humanos , Inibidores de Hidroximetilglutaril-CoA Redutases/uso terapêutico , Resultado do Tratamento
16.
Acta Orthop Traumatol Turc ; 53(4): 313-317, 2019 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-31155303

RESUMO

Malignant glomus tumors (MGTs) are exceptional but pose diagnostic and therapeutic challenges. Wide resection is the recommended treatment method, however, no data are available concerning adjuvant therapies. We present an exceptional case of extradigital deep-seated MGT of the forearm, with an exceptional bone infiltration. Despite being treated with wide resection, the patient had an optimal functional outcome, no functional loss, no motor or sensitive deficits and has returned to his full daily activity.


Assuntos
Neoplasias Ósseas , Dissecação/métodos , Antebraço , Tumor Glômico , Neoplasias de Tecidos Moles , Ulna , Atividades Cotidianas , Neoplasias Ósseas/patologia , Neoplasias Ósseas/secundário , Terapia Combinada/métodos , Antebraço/diagnóstico por imagem , Antebraço/patologia , Antebraço/cirurgia , Tumor Glômico/patologia , Tumor Glômico/fisiopatologia , Tumor Glômico/cirurgia , Humanos , Imageamento por Ressonância Magnética/métodos , Masculino , Pessoa de Meia-Idade , Invasividade Neoplásica , Estadiamento de Neoplasias , Radiografia/métodos , Neoplasias de Tecidos Moles/patologia , Neoplasias de Tecidos Moles/fisiopatologia , Neoplasias de Tecidos Moles/cirurgia , Resultado do Tratamento , Carga Tumoral , Ulna/lesões , Ulna/patologia
17.
Europace ; 10(8): 918-25, 2008 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-18541620

RESUMO

AIMS: Morphology discrimination (MD) is an algorithm based on QRS morphology analysis, that can be used alone or in various combinations with other discriminators in order to diagnose ventricular tachycardia (VT) [the implantable cardioverter-defibrillator (ICD) may be set to diagnose VT if 'Any' or 'All' the discriminators indicate VT)]. METHODS AND RESULTS: We evaluated the contribution of MD in terms of Specificity (SP) and Sensitivity (SE) of rhythm discrimination in slow and fast VT zones (rates <150 bpm and between 150 and 180 bpm, respectively). Detection results (682 spontaneous episodes in 58 patients) were corrected for multiple episodes within a patient (generalized estimating equations method). Rhythm discrimination in slow VT zones was characterized by SE and SP below 80% without MD, while the use of MD alone allowed to enhance SP, maintaining SE at 96%. Use of MD in combination with other discriminators resulted in a decrease in SP (setting 'Any'). In fast VT zones, MD allows an increase in SE for VT detection from around 82% up to approximately 94%, coupled with an SP of 95-96%., although SP is much higher with MD alone (94.8%) than with any other combination (78.4%). Both in slow and fast VT zones, use of multiple discriminators with the setting 'All' resulted in an unacceptable decrease in SE. CONCLUSION: MD in a dual-chamber ICD in combination with a rate branch classification system makes it possible to achieve a very high SP in discriminating detected events both in slow and fast VT zones, while maintaining SE for VT detection.


Assuntos
Algoritmos , Desfibriladores Implantáveis , Diagnóstico por Computador/métodos , Eletrocardiografia/métodos , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/prevenção & controle , Terapia Assistida por Computador/métodos , Idoso , Análise Discriminante , Feminino , Humanos , Masculino , Reconhecimento Automatizado de Padrão/métodos , Resultado do Tratamento
19.
J Cardiovasc Med (Hagerstown) ; 18(7): 478-489, 2017 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-28514791

RESUMO

AIMS: Atrial fibrillation recurrences after pulmonary vein isolation (PVI) are not uncommon and are frequently related to pulmonary vein reconnection. Adenosine/ATP can reveal dormant pulmonary vein conduction after PVI. Previous studies revealed that adenosine-guided Additional ablation could improve arrhythmia-free survival. We performed a meta-analysis to assess the impact of additional ablation to eliminate adenosine-induced transient pulmonary vein reconnection in terms of atrial fibrillation recurrence at follow-up. METHODS: MEDLINE/PubMed, Cochrane Library and references reporting atrial fibrillation ablation and adenosine/ATP-following PVI were screened, and studies were included if they matched inclusion and exclusion criteria. RESULTS: A total of 3524 patients were enrolled with a median follow-up of 13 (6-20) months. Overall, 70% (60-85) of patients in ATP-guided ablation vs. 63% (48-79) in no ATP-guided ablation were free of atrial fibrillation at follow-up. Pooled results revealed that ATP-guided ablation reduced the risk of atrial fibrillation recurrence of 42% [odds ratio (OR) 0.58, 0.41-0.81], but this result was primary because of the contribution of retrospective over-randomized studies [OR 0.48 (0.35-0.65) vs. 0.76 (0.42-1.40), respectively]. 3.2% of patients experienced an adverse event. ATP-guided ablation is related to a nonsignificant increase in fluoroscopy time (OR 1.71, 0.98-2.96) and to a significant increase in procedure time (OR 2.84, 1.32-6.09). CONCLUSION: Additional ablation aiming to eliminate adenosine-induced transient pulmonary vein reconnection failed to reduce the risk of atrial fibrillation recurrence at follow-up. Moreover, although adenosine-guided PVI is not affected by an augmented risk of adverse events, it is associated with a NS increased fluoroscopy exposure and significantly longer procedure duration. Further studies are required to identify the actual role of adenosine in PVI.


Assuntos
Trifosfato de Adenosina/administração & dosagem , Adenosina/administração & dosagem , Fibrilação Atrial/cirurgia , Ablação por Cateter , Técnicas Eletrofisiológicas Cardíacas , Veias Pulmonares/cirurgia , Adulto , Idoso , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/fisiopatologia , Ablação por Cateter/efeitos adversos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Razão de Chances , Valor Preditivo dos Testes , Veias Pulmonares/fisiopatologia , Recidiva , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento
20.
J Interv Card Electrophysiol ; 46(3): 225-36, 2016 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-27217030

RESUMO

PURPOSE: Apixaban, a direct factor Xa inhibitor recently approved for thromboembolic prophylaxis in patients with nonvalvular atrial fibrillation (AF), is increasingly used in patients undergoing catheter ablation of AF. However, large randomized studies supporting its use in the ablation context are still lacking. We undertook the present meta-analysis to assess the impact of apixaban in terms of thromboembolic and bleeding events in patients undergoing AF ablation as compared to warfarin. METHODS: MEDLINE/PubMed, Cochrane Library, and references reporting AF ablation and apixaban were screened and studies included if matching inclusion and exclusion criteria. RESULTS: One randomized and five nonrandomized studies were included in the analysis. Patients enrolled were 1691 patients (668 on apixaban and 1023 on warfarin). There was no heterogeneity in all the outcome comparisons. No deaths were reported. We did not observe any difference between apixaban and warfarin with respect to thromboembolic events (OR = 1.10, 95 % CI 0.24-5.16), major bleedings (OR = 1.56, 95 % CI 0.59-4.13), cardiac tamponade (OR 1.69, 95 % CI 0.52-5.54), minor bleedings (OR 0.96, 95 % CI 0.58-1.59), and the composite endpoint of death, thromboembolic events, and bleedings (OR 1.03, 95 % CI 0.65-1.64). CONCLUSIONS: The rates of death, thromboembolic events, major bleedings including cardiac tamponade, and minor bleedings in patients on apixaban undergoing AF ablation are very low and similar to that seen in patients treated with uninterrupted warfarin. Although primary driven by nonrandomized studies, these results support apixaban as periprocedural anticoagulation during AF ablation procedures.


Assuntos
Fibrilação Atrial/cirurgia , Ablação por Cateter/estatística & dados numéricos , Complicações Pós-Operatórias/epidemiologia , Pirazóis/administração & dosagem , Piridonas/administração & dosagem , Tromboembolia/epidemiologia , Tromboembolia/prevenção & controle , Administração Oral , Idoso , Anticoagulantes/administração & dosagem , Fibrilação Atrial/tratamento farmacológico , Fibrilação Atrial/epidemiologia , Causalidade , Comorbidade , Feminino , Fibrinolíticos/administração & dosagem , Humanos , Incidência , Masculino , Pessoa de Meia-Idade , Complicações Pós-Operatórias/prevenção & controle , Pré-Medicação/estatística & dados numéricos , Taxa de Sobrevida , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA