Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 55
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
Medicina (Kaunas) ; 60(5)2024 May 16.
Artigo em Inglês | MEDLINE | ID: mdl-38793002

RESUMO

Over the past decade, remote monitoring (RM) has become an increasingly popular way to improve healthcare and health outcomes. Modern cardiac implantable electronic devices (CIEDs) are capable of recording an increasing amount of data related to CIED function, arrhythmias, physiological status and hemodynamic parameters, providing in-depth and updated information on patient cardiovascular function. The extensive use of RM for patients with CIED allows for early diagnosis and rapid assessment of relevant issues, both clinical and technical, as well as replacing outpatient follow-up improving overall management without compromise safety. This approach is recommended by current guidelines for all eligible patients affected by different chronic cardiac conditions including either brady- and tachy-arrhythmias and heart failure. Beyond to clinical advantages, RM has demonstrated cost-effectiveness and is associated with elevated levels of patient satisfaction. Future perspectives include improving security, interoperability and diagnostic power as well as to engage patients with digital health technology. This review aims to update existing data concerning clinical outcomes in patients managed with RM in the wide spectrum of cardiac arrhythmias and Hear Failure (HF), disclosing also about safety, effectiveness, patient satisfaction and cost-saving.


Assuntos
Insuficiência Cardíaca , Humanos , Insuficiência Cardíaca/terapia , Insuficiência Cardíaca/diagnóstico , Arritmias Cardíacas/diagnóstico , Arritmias Cardíacas/terapia , Monitorização Fisiológica/métodos , Telemedicina/tendências , Desfibriladores Implantáveis/normas
2.
Pacing Clin Electrophysiol ; 46(10): 1215-1221, 2023 10.
Artigo em Inglês | MEDLINE | ID: mdl-37676730

RESUMO

Video-assisted thoracoscopic surgery (VATS) has revolutionized the approach and management of pulmonary and cardiac diseases, and its applications have significantly expanded in the last two decades. Beyond its established role in thoracic procedures, VATS has also emerged as a valuable technique for various electrophysiological procedures, including pacemaker implantations, ablation procedures, and left atrial appendage exclusion. This paper presents a thorough review of the existing literature on pacing procedures performed using a VATS approach. By analyzing and synthesizing the available studies, we aim to provide an in-depth understanding of the current knowledge and advancements in VATS-based pacing procedures. A key focus of this review is the detailed description of implantation techniques via a VATS approach.


Assuntos
Cardiopatias , Marca-Passo Artificial , Humanos , Cirurgia Torácica Vídeoassistida/métodos
3.
Medicina (Kaunas) ; 59(2)2023 Feb 19.
Artigo em Inglês | MEDLINE | ID: mdl-36837606

RESUMO

Electrical storm is a medical emergency characterized by ventricular arrythmia recurrence that can lead to hemodynamic instability. The incidence of this clinical condition is rising, mainly in implantable cardioverter defibrillator patients, and its prognosis is often poor. Early acknowledgment, management and treatment have a key role in reducing mortality in the acute phase and improving the quality of life of these patients. In an emergency setting, several measures can be employed. Anti-arrhythmic drugs, based on the underlying disease, are often the first step to control the arrhythmic burden; besides that, new therapeutic strategies have been developed with high efficacy, such as deep sedation, early catheter ablation, neuraxial modulation and mechanical hemodynamic support. The aim of this review is to provide practical indications for the management of electrical storm in acute settings.


Assuntos
Ablação por Cateter , Desfibriladores Implantáveis , Humanos , Qualidade de Vida , Arritmias Cardíacas , Antiarrítmicos/uso terapêutico , Prognóstico
4.
Pacing Clin Electrophysiol ; 44(8): 1404-1412, 2021 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-34224159

RESUMO

PURPOSE: To compare the outcome of paroxysmal atrial fibrillation (AF) ablation via pulmonary vein isolation using Ablation Index (AI) with strict or standard stability criteria. METHODS: We enrolled 130 consecutive naive patients affected by paroxysmal AF who underwent PVI at two high-volume centers. AI target was ≥380 at the posterior wall and ≥500 at the anterior wall. Strict versus standard stability criteria were set for Group 1 (65 patients) and Group 2 (65 patients), respectively. We compared those strategies with a historical cohort of 72 consecutive patients treated at same centers in the VISITALY study, using average force ≥10 g and strict stability criteria as target parameters. Interlesion distance target was <6 mm. Recurrence was defined as any AF, atrial tachycardia (AT) or atrial flutter (AFL) during the 12 months after ablation, excluding a 90-days blanking period. RESULTS: Procedure duration (224.05 ± 47.21 vs. 175.61 ± 51.29 min; p < .001), fluoroscopy time (11.85 ± 4.38 vs. 10.46 ± 6.49 min; p = .019) and pericardial effusion rate (9.23% vs. 0%; p = .01) were higher in Group 1 than in Group 2. Freedom from AF/AT/AFL at 12 months was not significantly different (Group 1: 86.15%; Group 2: 90.77%; p = .42). Compared to VISITALY study, there were not significant differences in terms of recurrences. CONCLUSION: A strategy of PVI using AI with standard stability criteria performed the best in terms of procedure efficiency and safety. Twelve-months arrhythmia-free survival rate was comparable with other strategies pursuing an interlesion distance target <6 mm, regardless of the use of AI.


Assuntos
Fibrilação Atrial/cirurgia , Veias Pulmonares/cirurgia , Ablação por Radiofrequência/normas , Feminino , Fluoroscopia , Humanos , Masculino , Pessoa de Meia-Idade , Duração da Cirurgia , Estudos Retrospectivos
5.
J Card Surg ; 36(11): 4403-4406, 2021 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-34418154

RESUMO

Atrial fibrillation in patients with heart failure due to ventricular dyssynchrony needs decision-making on the rate and rhythm control strategies together with cardiac resynchronization therapy and antithrombotic prophylaxis. Transvenous biventricular pacing and percutaneous appendage closure in patients with heart failure and atrial fibrillation with high bleeding risk are valid therapeutic options but anatomical exclusion criteria could be present. Here, we report two patients who underwent successful totally thoracoscopic concomitant left appendage occlusion and epicardial left ventricular lead implantation.


Assuntos
Apêndice Atrial , Fibrilação Atrial , Terapia de Ressincronização Cardíaca , Insuficiência Cardíaca , Apêndice Atrial/diagnóstico por imagem , Apêndice Atrial/cirurgia , Fibrilação Atrial/complicações , Fibrilação Atrial/terapia , Insuficiência Cardíaca/complicações , Insuficiência Cardíaca/terapia , Humanos , Toracoscopia , Resultado do Tratamento
6.
J Cardiovasc Electrophysiol ; 31(8): 2187-2191, 2020 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-32495408

RESUMO

INTRODUCTION: The most appropriate treatment for stroke prevention in standalone atrial fibrillation patients with a high CHADS2VASC score contraindicated for oral anticoagulation (OAC) or novel OAC (NOAC) still needs to be defined. Percutaneous left atrial appendage (LAA) closure devices are available, but because of their endocardial positioning need a period of antiplatelet therapy (APT). This study aimed to evaluate the safety and efficacy of epicardial left atrial appendage clipping in patients contraindicated for (N)OAC and APT. METHODS AND RESULTS: We describe a standalone totally thoracoscopic LAA clipping of forty-five consecutive patients with nonvalvular atrial fibrillation (NVAF; 32 males; age, 73.1 ± 7.4 years; CHADVASC, 6.5 ± 1.1; HAS-BLED 4.9 ± 0.9) with absolute contraindications to (N)OAC. The patients were selected by a multidisciplinary Heart Team. Sixty percent had a previous ischemic stroke and 51% a history of the hemorrhagic event and 22% both. All patients were implanted with an LAA epicardial clip, guided by preoperative computed tomography and intraoperative transesophageal echocardiography. The mean procedural duration was 52.3 ± 12.6 minutes with postprocedural extubation interval of 22.8 ± 14.6 minutes. No procedure-related complications occurred. Intraprocedural transesophageal echocardiography (TEE) showed complete LAA occlusion in all patients. At a mean follow-up of 16.4 ± 9.1 months (range, 2-34), with all patients off (N)OAC or APT, no ischemic stroke or hemorrhagic complications occurred. computed tomography or TEE at follow-up demonstrated a correct LAA occlusion in all with mean stumps of 3.3 ± 2.8 mm. CONCLUSION: Thoracoscopic epicardial closure of the LAA with the AtriClip PRO2 device is a potentially safe and efficient treatment for stroke prevention in patients with NVAF contraindicated for anticoagulant therapy or APT.


Assuntos
Apêndice Atrial , Fibrilação Atrial , Isquemia Encefálica , AVC Isquêmico , Acidente Vascular Cerebral , Idoso , Anticoagulantes/efeitos adversos , Apêndice Atrial/diagnóstico por imagem , Apêndice Atrial/cirurgia , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/diagnóstico por imagem , Ecocardiografia Transesofagiana , Humanos , Masculino , Acidente Vascular Cerebral/diagnóstico , Acidente Vascular Cerebral/etiologia , Acidente Vascular Cerebral/prevenção & controle , Resultado do Tratamento
8.
Circ J ; 82(4): 974-982, 2018 03 23.
Artigo em Inglês | MEDLINE | ID: mdl-29415917

RESUMO

BACKGROUND: Our aim was to evaluate the clinical outcome of paroxysmal atrial fibrillation (AF) ablation with contact force technology, using an automated lesion tagging system (VISITAGTM module) with strict criteria of catheter stability.Methods and Results:We enrolled 200 consecutive patients who underwent pulmonary vein isolation (PVI) in 11 centers and were followed up for 12 months. The stability setting was within 3 mm for ≥10 s and for ≥15 s in 47% and 53% of patients, respectively. A mean of 67.2±21.9 VISITAGs was acquired. Freedom from atrial tachyarrhythmias at follow-up was 77.5% (155/200), and the contiguity between lesions was associated with a higher chronic success rate (96% vs. 77.1%; log-rank P=0.036). Radiofrequency (RF), fluoroscopy times, and recurrence rates at the 12-month follow-up were significantly lower than in a comparison group of 80 patients without VISITAGTM module (42.7±14.5 vs. 50.9±23.6 min; P=0.032; 11.6±7.8 vs. 18.4±12.8 min; P=0.003 and 22.5% vs. 41.2%; P=0.02). Two major complications (1 cardiac tamponade and 1 minor stroke) were observed only in the control group. CONCLUSIONS: Paroxysmal AF ablation with contact force technology and strict criteria of stability using the VISITAG module was a safe procedure, associated with an improvement in efficiency and a reduction of atrial tachyarrhythmia recurrence at the 12-month follow-up compared with manual annotation. Contiguity between lesions seemed to enhance effectiveness outcomes.


Assuntos
Fibrilação Atrial/terapia , Ablação por Cateter/métodos , Veias Pulmonares/fisiopatologia , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Estudos de Casos e Controles , Ablação por Cateter/efeitos adversos , Ablação por Cateter/instrumentação , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Recidiva , Taquicardia/patologia , Taquicardia/prevenção & controle , Resultado do Tratamento , Adulto Jovem
9.
Echocardiography ; 35(5): 750-752, 2018 05.
Artigo em Inglês | MEDLINE | ID: mdl-29569266

RESUMO

Mitral regurgitation secondary to accessory mitral valve (MV) chordae of the left atrium is an extremely rare congenital disease. A 85-year-old female (NYHA I-II) was hospitalized for investigations. An echocardiogram showed calcification of the MV with mild stenosis and moderate regurgitation. Transesophageal three-dimensional echocardiogram revealed a band-like structure extending from the distal third of the anterior wall of the left atrium to the MV. This accessory chordae determined severe systolic regurgitation and mild mitral stenosis. The patient was referred for consideration of cardiac surgery but was refused for comorbidities and anatomy. Usually aberrant chordae determinant valvulopathies are detected and treated at a much younger age. The delay of the symptoms could be explained in our case with the progressive growth and dilatation of the left atrium causing traction of the aberrant chord resulting in an increase in the leaflet prolapse and regurgitation.


Assuntos
Cordas Tendinosas/diagnóstico por imagem , Diagnóstico Tardio , Ecocardiografia Doppler em Cores/métodos , Ecocardiografia Transesofagiana , Cardiopatias Congênitas/complicações , Insuficiência da Valva Mitral/etiologia , Valva Mitral/anormalidades , Idoso de 80 Anos ou mais , Cordas Tendinosas/anormalidades , Feminino , Cardiopatias Congênitas/diagnóstico por imagem , Humanos , Valva Mitral/diagnóstico por imagem , Insuficiência da Valva Mitral/diagnóstico por imagem , Índice de Gravidade de Doença
10.
Pediatr Cardiol ; 39(8): 1581-1589, 2018 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-29948026

RESUMO

The aim of this study is to evaluate the cost-effectiveness of an extended use of 3D non-fluoroscopic mapping systems (NMSs) during paediatric catheter ablation (CA) in an adult EP Lab. This study includes 58 consecutive patients (aged between 8 and 18) who underwent CA from March 2005 to February 2015. We compare the fluoroscopy data of two groups: group I, patients who underwent CA from 2005 to 2008 using only fluoroscopy, and group II, patients who underwent CA from 2008 to 2015 performed also using NMSs. Two cost-effectiveness analyses were carried out: the first method was based on the alpha value (AV), and the second one was based on the value of a statistical life (VSL). For both methods, a children's correction factor was also considered. The reduction cost estimated from all these methods was compared to the real additional cost of using NMSs. The use of an NMS during a CA procedure has led to an effective dose reduction (ΔE) of 2.8 milli-Sievert. All presented methods are based on parameters with a wide range of values. The use of an NMS, applying directly AV values or VSL values, is not cost-effective for most countries. Only considering the children's correction factor, the CA procedure using an NMS seems to be cost-effective. The cost-effectiveness of a systematic use of NMSs during CA procedures in children and teenagers remains a challenging task. A positive result depends on which value of AV or VSL is considered and if the children's correction factor is applied or not.


Assuntos
Ablação por Cateter/métodos , Fluoroscopia/economia , Imageamento Tridimensional/economia , Adolescente , Mapeamento Potencial de Superfície Corporal/economia , Ablação por Cateter/economia , Criança , Análise Custo-Benefício , Feminino , Fluoroscopia/métodos , Humanos , Masculino , Exposição à Radiação/prevenção & controle
11.
Pediatr Cardiol ; 37(4): 802-9, 2016 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-26932365

RESUMO

Standard imaging during electrophysiological procedures (EPs) uses fluoroscopy. The aim of this study was to evaluate the feasibility, efficacy, safety and effect of an extended use of non-fluoroscopic mapping systems (NMSs) for imaging during paediatric EPs in an adult EP laboratory focusing on the amount of X-ray exposure. This study is a retrospective analysis that includes consecutive young patients (83 pts, aged between 8 and 18) who underwent EPs from March 2005 to February 2015. We compare the fluoroscopy data of two groups of pts: Group I, pts who underwent EPs from 2005 to 2008 using only fluoroscopy and Group II, pts who underwent EPs from 2008 to 2015 performed also using NMSs. The use of an NMS resulted in reduced fluoroscopy time in Group II {median value 0.1 min (95 % CI [0.00-1.07])} compared to Group I {median value 3.55 min (95 % CI [1.93-7.83]) (MW test, P < 0.05)}. There was a complementary reduction in the total X-ray exposure from 2.53 Gy cm(2) (95 % CI [1.51-4.66]) in Group I to 0.05 Gy cm(2) in Group II (95 % CI [0.00-1.22]) (MW test, P < 0.05). Regarding ablation procedures, the median effective dose decreased from 3.04 mSv (95 % CI [1.22-6.89]) to 0.25 mSv (95 % CI [0.00-0.60]) (MW test, P < 0.05). The use of an NMS dramatically reduces fluoroscopy time and total X-ray exposure during EPs in children and teenagers in an adult EP laboratory. In our experience, this reduction is mainly related to the systematic day-to-day use of NMSs.


Assuntos
Arritmias Cardíacas/cirurgia , Ablação por Cateter/métodos , Fluoroscopia , Imageamento Tridimensional/métodos , Doses de Radiação , Adolescente , Criança , Feminino , Humanos , Estimativa de Kaplan-Meier , Masculino , Estudos Retrospectivos
12.
J Clin Med ; 13(2)2024 Jan 14.
Artigo em Inglês | MEDLINE | ID: mdl-38256590

RESUMO

Arrhythmogenic cardiomyopathy (ACM) is a heart disease characterized by a fibrotic replacement of myocardial tissue and a consequent predisposition to ventricular arrhythmic events, especially in the young. Post-mortem studies and the subsequent diffusion of cardiac MRI have shown that left ventricular involvement in arrhythmogenic cardiomyopathy is common and often develops early. Regarding the arrhythmic risk stratification, the current scores underestimate the arrhythmic risk of patients with arrhythmogenic cardiomyopathy with left involvement. Indeed, the data on arrhythmic risk stratification in this group of patients are contradictory and not exhaustive, with the consequence of not correctly identifying patients at a high arrhythmic risk who deserve protection from arrhythmic death. We propose a literature review on arrhythmic risk stratification in patients with ACM and left involvement to identify the main features associated with an increased arrhythmic risk in this group of patients.

13.
Heart Rhythm ; 2024 Jun 20.
Artigo em Inglês | MEDLINE | ID: mdl-38908459

RESUMO

BACKGROUND: Studies evaluating the systematic use of cardiac computer tomography (CCT) for the pre-procedural assessment of myocardial fibrosis are limited and their implementation in the electrophysiology workflow has not been extensively described. OBJECTIVE: To explore the degree of concordance between cardiac fibrosis evaluated by CCT compared to electroanatomical mapping (EAM) in patients undergoing endo-epicardial ventricular tachycardia (VT) ablation. METHODS: From November-2017 to December-2021, patients undergoing endo-epicardial VT catheter ablation (CA) with CCT as the only source of pre-procedural scar assessment were prospectively enrolled. After image integration, myocardial fibrosis detected with CCT was compared with low voltage areas identified by endo-epicardial EAM. Post-procedural VT recurrences of this approach were evaluated after at least one-year follow-up. RESULTS: 35 patients (mean age 60.7±13.2 years, 94.2% males) were enrolled. The most common underlying arrhythmic substrate was dilated cardiomyopathy (48.6%). CCT was employed for contraindications to cardiac magnetic resonance, as unstable VTs (31.4%) or non-conditional ICDs (28.8%), but also for patients' and operators' preferences (14.3%-25.7%). Myocardial fibrosis was correctly identified by CCT and EAM, with strong agreement between these two techniques, both overall (Cohen's Kappa for agreement=0.933) and in per-segment analysis (K ranging from 0.796 to 1.0). Ischemic patients showed the best correlation (K=1.000) while myocarditis showed the worst (K=0.750). After a median follow-up of 14 [12-24] months, 1-year freedom from recurrences was achieved in 74.3% patients; overall freedom from recurrences was 60.0%. CONCLUSIONS: A CCT-based pre-procedural assessment pre-VT ablation is feasible, showing high diagnostic concordance with EAM in detecting myocardial fibrosis.

14.
J Cardiovasc Med (Hagerstown) ; 25(6): 429-437, 2024 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-38625830

RESUMO

AIMS: In this study, we investigated a cohort of unselected patients with various indications for an implantable cardiac monitor (ICM). Our main objectives were to determine the incidence of arrhythmic diagnoses, both anticipated and incidental in relation to the ICM indication, and to assess their clinical relevance. METHODS: We examined remote monitoring transmissions from patients with an ICM at four Italian sites to identify occurrences of cardiac arrhythmias. Concurrently, we collected data on medical actions taken in response to arrhythmic findings. RESULTS: The study included 119 patients, with a median follow-up period of 371 days. ICM indications were syncope/presyncope (46.2%), atrial fibrillation management (31.1%), and cryptogenic stroke (22.7%). In the atrial fibrillation management group, atrial fibrillation was the most common finding, with an incidence of 36% [95% confidence interval (CI) 22-55%] at 18 months. Rates of atrial fibrillation were not significantly different between patients with cryptogenic stroke and syncope/presyncope [17% (95% CI 7-40%) vs. 8% (95% CI 3-19%), P  = 0.229].For patients with cryptogenic stroke, the incidence of asystole and bradyarrhythmias at 18 months was 23% (95% CI 11-45%) and 42% (95% CI 24-65%), respectively, similar to estimates obtained for patients implanted for syncope/presyncope ( P  = 0.277 vs. P  = 0.836).Overall, 30 patients (25.2%) required medical intervention following ICM-detected arrhythmias, predominantly involving atrial fibrillation ablation (10.9%) and medication therapy changes (10.1%). CONCLUSION: In a real-life population with heterogeneous insertion indications, approximately 25% of patients received ICM-guided medical interventions within a short timeframe, including treatments for incidental findings. Common incidental arrhythmic diagnoses were bradyarrhythmias in patients with cryptogenic stroke and atrial fibrillation in patients with unexplained syncope.


Assuntos
Arritmias Cardíacas , Fibrilação Atrial , Eletrocardiografia Ambulatorial , Síncope , Humanos , Masculino , Feminino , Idoso , Pessoa de Meia-Idade , Itália/epidemiologia , Eletrocardiografia Ambulatorial/instrumentação , Arritmias Cardíacas/diagnóstico , Arritmias Cardíacas/terapia , Arritmias Cardíacas/epidemiologia , Arritmias Cardíacas/fisiopatologia , Síncope/diagnóstico , Síncope/etiologia , Síncope/epidemiologia , Síncope/terapia , Síncope/fisiopatologia , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/epidemiologia , Fibrilação Atrial/complicações , Fibrilação Atrial/terapia , Fibrilação Atrial/fisiopatologia , Incidência , Achados Incidentais , Bradicardia/diagnóstico , Bradicardia/epidemiologia , Bradicardia/terapia , Bradicardia/fisiopatologia , Idoso de 80 Anos ou mais , Fatores de Tempo
15.
Can J Cardiol ; 2024 Mar 15.
Artigo em Inglês | MEDLINE | ID: mdl-38492735

RESUMO

BACKGROUND: In patients with atrial fibrillation (AF) on vitamin K antagonist (VKA) therapy and therapeutic international normalized ratio (INR) range, the incidence of cardiac thromboembolism is not negligible, and the subgroup of patients who have a mechanical prosthetic mitral valve (PMV) has the highest risk. We aimed to assess the long-term effects of left atrial appendage closure (LAAC) in AF patients with a mechanical PMV who experienced a failure of VKA therapy. METHODS: In this retrospective, multicentre study, patients underwent LAAC because of thrombotic events including transient ischemic attack and/or stroke, systemic embolism, and evidence of left atrial appendage thrombosis and/or sludge, despite VKA therapy, were enrolled. Patients with a mechanical PMV were included and compared with those affected by nonvalvular AF. The primary endpoint was the composite of all-cause death, major cardiovascular events, and major bleedings at follow-up. The feasibility and safety of LAAC also were assessed. RESULTS: A total of 55 patients (42% female; mean age, 70 ± 9 years), including 12 with a mechanical PMV, were enrolled. The most-frequent indication to LAAC (71%) was LAA thrombosis or sludge. Procedural success was achieved in 96% of overall cases, and in 100% of patients with a PMV. In 35 patients, a cerebral protection device was used. During a median follow-up of 6.1 ± 4.3 years, 4 patients with a PMV, and 20 patients without a PMV, reported adverse events (hazard ratio 0.73 [95% confidence interval 0.25-2.16, P = 0.564]). CONCLUSIONS: LAAC seems to be a valuable alternative in patients with AF who have a mechanical PMV, with failure of VKA therapy. This off-label, real-world clinical practice indication deserves validation in further studies.

16.
Diagnostics (Basel) ; 14(2)2024 Jan 14.
Artigo em Inglês | MEDLINE | ID: mdl-38248058

RESUMO

Fluoroscopy has always been the cornerstone imaging method of interventional cardiology procedures. However, radiation exposure is linked to an increased risk of malignancies and multiorgan diseases. The medical team is even more exposed to X-rays, and a higher incidence of malignancies was reported in this professional group. In the last years, X-ray exposure has increased rapidly, involving, above all, the medical team and young patients and forcing alternative fluoroless imaging methods. In cardiac electrophysiology (EP) and pacing, the advent of 3D electroanatomic mapping systems with dedicated catheters has allowed real-time, high-density reconstruction of both heart anatomy and electrical activity, significantly reducing the use of fluoroscopy. In addition, the diffusion of intracardiac echocardiography has provided high anatomical resolution of moving cardiac structures, providing intraprocedural guidance for more complex catheter ablation procedures. These methods have largely demonstrated safety and effectiveness, allowing for a dramatic reduction in X-ray delivery in most arrhythmias' ablations. However, some technical concerns, as well as higher costs, currently do not allow their spread out in EP labs and limit their use to only procedures that are considered highly complex and time-consuming and in young patients. In this review, we aim to update the current employment of fluoroless imaging in different EP procedures, focusing on its strengths and weaknesses.

17.
Heart Rhythm ; 2024 Jan 20.
Artigo em Inglês | MEDLINE | ID: mdl-38246567

RESUMO

BACKGROUND: Long-term oral anticoagulation is the mainstay therapy for thromboembolic (TE) prevention in patients with atrial fibrillation. However, left atrial appendage occlusion (LAAO) could be a safe alternative to direct oral anticoagulants (DOACs) in patients with a very high TE risk profile. OBJECTIVE: The purpose of this study was to compare the safety and efficacy of LAAO vs DOACs in patients with atrial fibrillation at very high stroke risk (CHA2DS2-VASc [congestive heart failure, hypertension, age ≥ 75 years, diabetes mellitus, prior stroke or transient ischemic attack or thromboembolism, vascular disease, age 65-74 years, sex category] score ≥ 5). METHODS: Data from patients with CHA2DS2-VASc score ≥ 5 were extracted from a prospective multicenter database. To attenuate the imbalance in covariates between groups, propensity score matching was used (covariates: CHA2DS2-VASc and HAS-BLED [hypertension, abnormal renal or liver function, stroke, bleeding, labile international normalized ratio, elderly, drugs or alcohol] scores), which resulted in a matched population of 277 patients per group. The primary end point was a composite of cardiovascular death, TE events, and clinically relevant bleeding during follow-up. RESULTS: Of 2381 patients, 554 very high risk patients were included in the study (mean age 79 ± 7 years; CHA2DS2-VASc score 5.8 ± 0.9; HAS-BLED score 3.0 ± 0.9). The mean follow-up duration was 25 ± 11 months. A higher incidence of the composite end point was documented with DOACs compared with LAAO (14.9 events per 100 patient-years in the DOAC group vs 9.4 events per 100 patient-years in the LAAO group; P = .03). The annualized clinically relevant bleeding risk was higher with DOACs (6.3% vs 3.2%; P = .04), while the risk of TE events was not different between groups (4.1% vs 3.2%; P = .63). CONCLUSION: In high-risk patients, LAAO had a similar stroke prevention efficacy but a significantly lower risk of clinically relevant bleeding when compared with DOACs. The clinical benefit of LAAO became significant after 18 months of follow-up.

18.
Int J Cardiol ; 389: 131199, 2023 10 15.
Artigo em Inglês | MEDLINE | ID: mdl-37481001

RESUMO

BACKGROUND: Remote Monitoring (RM) is recognized for its ability to enhance the clinical management of patients with implantable cardiac monitor (ICM). This study aims to provide a comprehensive description of the arrhythmic episodes transmitted by a daily and automatic RM system from a cohort of ICM patients. METHODS: The study retrospectively analyzed daily transmissions from consecutive patients who had been implanted with a long-sensing vector ICM (BIOMONITOR III/IIIm) at four sites. All transmitted arrhythmic recordings were evaluated to determine whether they were true positive episodes or false positives (FP). RESULTS: A total of 14,136 episodes were transmitted from 119 patients (74.8% male, median age 62 years old) during a median follow-up of 371 days. The rate of arrhythmic episodes was 14.2 per patient-year (interquartile range: 1.8-126), with 97 patients (81.5%) experiencing at least one ICM activation. Fifty-five percent of episodes were identified as FP, and 67 patients (56.3%) had at least one inappropriate activation. The FP rate was 1.4 per patient-year (0-40). The best per-episode predictive positive values were observed for bradycardia and atrial fibrillation (0.595 and 0.553, respectively). Notably, the implementation of an algorithm designed to minimize false detections significantly reduced the prevalence of atrial fibrillation FP episodes (17.6% vs. 43.5%, p = 0.008). CONCLUSION: Daily and automatic RM appears to be a reliable tool for the comprehensive remote management of ICM patients. However, the number of arrhythmic episodes requiring review is high, and further improvements are needed to reduce FP and facilitate accurate interpretation of transmissions.


Assuntos
Fibrilação Atrial , Desfibriladores Implantáveis , Humanos , Masculino , Pessoa de Meia-Idade , Feminino , Estudos Retrospectivos , Eletrocardiografia Ambulatorial , Eletrocardiografia , Algoritmos
19.
J Cardiovasc Dev Dis ; 10(4)2023 Apr 17.
Artigo em Inglês | MEDLINE | ID: mdl-37103051

RESUMO

Ventricular tachycardia in patients with structural heart disease is a significant cause of morbidity and mortality. According to current guidelines, cardioverter defibrillator implantation, antiarrhythmic drugs, and catheter ablation are established therapies in the management of ventricular arrhythmias but their efficacy is limited in some cases. Sustained ventricular tachycardia can be terminated by cardioverter-defibrillator therapies although shocks in particular have been demonstrated to increase mortality and worsen patients' quality of life. Antiarrhythmic drugs have important side effects and relatively low efficacy, while catheter ablation, even if it is actually an established treatment, is an invasive procedure with intrinsic procedural risks and is frequently affected by patients' hemodynamic instability. Stereotactic arrhythmia radioablation for ventricular arrhythmias was developed as bail-out therapy in patients unresponsive to traditional treatments. Radiotherapy has been mainly applied in the oncological field, but new current perspectives have developed in the field of ventricular arrhythmias. Stereotactic arrhythmia radioablation provides an alternative non-invasive and painless therapeutic strategy for the treatment of previously detected cardiac arrhythmic substrate by three-dimensional intracardiac mapping or different tools. Since preliminary experiences have been reported, several retrospective studies, registries, and case reports have been published in the literature. Although, for now, stereotactic arrhythmia radioablation is considered an alternative palliative treatment for patients with refractory ventricular tachycardia and no other therapeutic options, this research field is currently extremely promising.

20.
J Cardiovasc Med (Hagerstown) ; 24(3): 191-199, 2023 03 01.
Artigo em Inglês | MEDLINE | ID: mdl-36753726

RESUMO

AIMS: To assess the characteristics of left atrial appendage (LAA) stump and left atrial (LA) volume after standalone totally thoracoscopic LAA exclusion in 40 patients with nonvalvular atrial fibrillation (NVAF) and contraindications to oral anticoagulation (OAC), using cardiac computed tomography (CCT) and transoesophageal echocardiography (TOE). METHODS: Using CCT and TOE, we evaluated correct AtriClip Pro II positioning, the presence and characteristics of the LAA stump and the postprocedural LA volume, at 3 months' follow-up. Stump depth was measured with both CCT and TOE using a new method, based on left circumflex artery (LCX) course. RESULTS: After placement of AtriClip, all 40 patients discontinued OAC, and no stroke occurred. LAA exclusion was achieved in 40/40 patients at 3 months' follow-up. LAA stump (depth <10 mm in 12/18 stump, 67%) was observed in 18 patients. The overall (LA + LAA) volume and isolated LA volume were statistically different when comparing cases with and without LAA stump (P < 0.02). LAA ostium dimensions (perimeter and area) and LAA volume correlate with stump depth (P < 0.02). There was a high correlation between CCT and TOE in stump identification and depth measurement (P < 0.02). Compared with the baseline, CCT LA volume increased (P < 0.01) at 3 months' follow-up. CONCLUSION: Preprocedural and postprocedural CCT and TOE are useful and comparable in patients undergoing standalone totally thoracoscopic exclusion of LAA, because these imaging methods can identify anatomical LAA and LA characteristics predisposing for a postprocedural residual stump.


Assuntos
Apêndice Atrial , Fibrilação Atrial , Acidente Vascular Cerebral , Humanos , Apêndice Atrial/diagnóstico por imagem , Apêndice Atrial/cirurgia , Fibrilação Atrial/diagnóstico por imagem , Fibrilação Atrial/cirurgia , Fibrilação Atrial/complicações , Ecocardiografia Transesofagiana , Acidente Vascular Cerebral/etiologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA