Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Nano Lett ; 24(33): 10284-10289, 2024 Aug 21.
Artigo em Inglês | MEDLINE | ID: mdl-39133900

RESUMO

Remote and van der Waals epitaxy are promising approaches for synthesizing single crystalline membranes for flexible electronics and discovery of new properties via extreme strain; however, a fundamental challenge is that most materials do not wet the graphene surface. We develop a cold seed approach for synthesizing smooth intermetallic films on graphene that can be exfoliated to form few nanometer thick single crystalline membranes. Our seeded GdAuGe films have narrow X-ray rocking curve widths of 9-24 arc seconds, which is 2 orders of magnitude lower than their counterparts grown by typical high temperature methods, and have atomically sharp interfaces observed by transmission electron microscopy. Upon exfoliation and rippling, strain gradients in GdAuGe membranes induce an antiferromagnetic to ferri/ferromagnetic transition. Our smooth, ultrathin membranes provide a clean platform for discovering new flexomagnetic effects in quantum materials.

2.
Microsc Microanal ; 29(6): 2026-2036, 2023 Dec 21.
Artigo em Inglês | MEDLINE | ID: mdl-38066670

RESUMO

Electron counting can be performed algorithmically for monolithic active pixel sensor direct electron detectors to eliminate readout noise and Landau noise arising from the variability in the amount of deposited energy for each electron. Errors in existing counting algorithms include mistakenly counting a multielectron strike as a single electron event, and inaccurately locating the incident position of the electron due to lateral spread of deposited energy and dark noise. Here, we report a supervised deep learning (DL) approach based on Faster region-based convolutional neural network (R-CNN) to recognize single electron events at varying electron doses and voltages. The DL approach shows high accuracy according to the near-ideal modulation transfer function (MTF) and detector quantum efficiency for sparse images. It predicts, on average, 0.47 pixel deviation from the incident positions for 200 kV electrons versus 0.59 pixel using the conventional counting method. The DL approach also shows better robustness against coincidence loss as the electron dose increases, maintaining the MTF at half Nyquist frequency above 0.83 as the electron density increases to 0.06 e-/pixel. Thus, the DL model extends the advantages of counting analysis to higher dose rates than conventional methods.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA