Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 44
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
Clin Radiol ; 2024 Aug 31.
Artigo em Inglês | MEDLINE | ID: mdl-39322532

RESUMO

AIMS: There is no comprehensive data collection outlining the numbers and types of interventional radiology (IR) procedures in the United Kingdom. Similarly, limited data are available on the IR facilities and workforce within the National Health Services (NHS) trusts. The purpose of this study is to evaluate the number/type of IR procedures, facilities, and workforces across England and Wales. MATERIALS AND METHODS: This retrospective study used the 2000 Freedom of Information Act to obtain information regarding the IR procedures performed in NHS trusts in England and Wales from 2017 to 2021. We collected additional information on IR workforce and facilities, including the number of IR consultants, nurses, trainees, and angiographic suites and day case units; analysed procedures by complexity; and performed data analysis by region. RESULTS: A total of 1,340,352 IR procedures were analysed. An increasing trend was observed in the number of IR procedures from 2017 to 2021 (p=0.07, R=0.93). There were more intermediate and complex procedures than simple ones (p=0.0001). Notable geographical variation was observed in terms of IR facilities including angiographic suites and day case units, and the number of IR consultants, nurses, and trainees. CONCLUSIONS: The IR field continues to grow as evidenced by increasing trends in the number and complexity of the procedures over the years. There is an uneven IR workforce, services, and facilities distribution across England and Wales. Therefore, there is a crucial need for centralised data collection to evaluate and monitor interventions besides comprehensive revision of UK IR service provision.

2.
Eur Radiol ; 31(12): 8897-8902, 2021 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-34109488

RESUMO

INTRODUCTION: CT-guided interventions are taught using a mentored approach on real patients. It is well established that simulation is a valuable training tool in medicine. This project assessed the feasibility and acceptance of replicating a CT-guided intervention using a bespoke software application with an augmented reality head-mounted display (ARHMD). METHODS: A virtual patient was generated using a CT dataset obtained from The Cancer Imaging Archive. A surface mesh of a virtual patient was projected into the field-of-view of the operator. ChArUco markers, placed on both the needle and agar jelly phantom, were tracked using RGB cameras built into the ARHMD. A virtual CT slice simulating the needle position was generated on voice command. The application was trialled by senior interventional radiologists and trainee radiologists with a structured questionnaire evaluating face validity and technical aspects. RESULTS: Sixteen users trialled the application and feedback was received from all. Eleven felt the accuracy and realism was adequate for training and twelve felt more confident about their CT biopsy skills after this training session. DISCUSSION: The study showed the feasibility of simulating a CT-guided procedure with augmented reality and that this could be used as a training tool. KEY POINTS: • Simulating a CT-guided procedure using augmented reality is possible. • The simulator developed could be an effective training tool for clinical practical skills. • Complexity of cases can be tailored to address the training level demands.


Assuntos
Realidade Aumentada , Simulação por Computador , Humanos , Agulhas , Imagens de Fantasmas , Tomografia Computadorizada por Raios X , Interface Usuário-Computador
4.
Br J Surg ; 105(4): 366-378, 2018 03.
Artigo em Inglês | MEDLINE | ID: mdl-29431856

RESUMO

BACKGROUND: Silent cerebral infarction is brain injury detected incidentally on imaging; it can be associated with cognitive decline and future stroke. This study investigated cerebral embolization, silent cerebral infarction and neurocognitive decline following thoracic endovascular aortic repair (TEVAR). METHODS: Patients undergoing elective or emergency TEVAR at Imperial College Healthcare NHS Trust and Guy's and St Thomas' NHS Foundation Trust between January 2012 and April 2015 were recruited. Aortic atheroma graded from 1 (normal) to 5 (mobile atheroma) was evaluated by preoperative CT. Patients underwent intraoperative transcranial Doppler imaging (TCD), preoperative and postoperative cerebral MRI, and neurocognitive assessment. RESULTS: Fifty-two patients underwent TEVAR. Higher rates of TCD-detected embolization were observed with greater aortic atheroma (median 207 for grade 4-5 versus 100 for grade 1-3; P = 0·042), more proximal landing zones (median 450 for zone 0-1 versus 72 for zone 3-4; P = 0·001), and during stent-graft deployment and contrast injection (P = 0·001). In univariable analysis, left subclavian artery bypass (ß coefficient 0·423, s.e. 132·62, P = 0·005), proximal landing zone 0-1 (ß coefficient 0·504, s.e. 170·57, P = 0·001) and arch hybrid procedure (ß coefficient 0·514, s.e. 182·96, P < 0·001) were predictors of cerebral emboli. Cerebral infarction was detected in 25 of 31 patients (81 per cent) who underwent MRI: 21 (68 per cent) silent and four (13 per cent) clinical strokes. Neurocognitive decline was seen in six of seven domains assessed in 15 patients with silent cerebral infarction, with age a significant predictor of decline. CONCLUSION: This study demonstrates a high rate of cerebral embolization and neurocognitive decline affecting patients following TEVAR. Brain injury after TEVAR is more common than previously recognized, with cerebral infarction in more than 80 per cent of patients.


Assuntos
Aorta Torácica/cirurgia , Infarto Cerebral/etiologia , Procedimentos Endovasculares , Embolia Intracraniana/etiologia , Transtornos Neurocognitivos/etiologia , Placa Aterosclerótica/cirurgia , Complicações Pós-Operatórias/etiologia , Idoso , Idoso de 80 Anos ou mais , Infarto Cerebral/diagnóstico , Infarto Cerebral/epidemiologia , Feminino , Seguimentos , Humanos , Incidência , Embolia Intracraniana/diagnóstico , Embolia Intracraniana/epidemiologia , Modelos Lineares , Modelos Logísticos , Masculino , Pessoa de Meia-Idade , Transtornos Neurocognitivos/diagnóstico , Transtornos Neurocognitivos/epidemiologia , Complicações Pós-Operatórias/diagnóstico , Complicações Pós-Operatórias/epidemiologia , Fatores de Risco
5.
Eur J Vasc Endovasc Surg ; 53(3): 362-369, 2017 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-28214128

RESUMO

OBJECTIVE: Stroke caused by cerebral embolization constitutes a principal risk during arch manipulation and thoracic endovascular aortic repair (TEVAR). This study investigates the incidence of cerebral embolization during catheter placement in the aortic arch, and compares robotic and manual techniques. METHODS: Intra-operative transcranial Doppler (TCD) was performed in 11 patients undergoing TEVAR. Wire and catheter placement in the arch was performed by two experienced operators. Manual and robotic catheter placement and removal were compared for each patient; 44 manoeuvres were studied in total. A conventional 5Fr pigtail catheter was used for manual cannulation via a 5Fr access sheath. The 6Fr/9Fr co-axial Magellan endovascular robotic system was used for robotic navigation operated from a remote workstation. The number of high intensity transient signals (HITS) detected by TCD during different stages of TEVAR was recorded. RESULTS: The median procedural embolization rate was 173 (interquartile range 97-240). There were significantly fewer HITS detected during robotic catheter placement with six in total (median 0, IQR 0-1), compared with 38 HITS (median 2, IQR 1-5) during manual catheter placement (p = .018). There were no HITS detected during robotic catheter removal by auto-retraction as per manufacturer instructions. On two occasions, however, when the robotic catheter system was removed manually without correcting for articulation, it resulted in one HIT in one case and 11 HITS in the second case. CONCLUSIONS: Robotic catheter placement is feasible during TEVAR, and results in significantly less cerebral embolization compared with manual techniques. The active manoeuvrability, control, and stability of the robotic system is likely to reduce contact with an atheromatous aortic arch wall, and thereby reduce dislodgement of particulate matter and result in less embolization. The importance of adhering to manufacturer instructions during use and removal of the robotic catheter is also highlighted.


Assuntos
Aorta Torácica/cirurgia , Implante de Prótese Vascular/instrumentação , Procedimentos Endovasculares/instrumentação , Embolia Intracraniana/prevenção & controle , Procedimentos Cirúrgicos Robóticos/instrumentação , Dispositivos de Acesso Vascular , Idoso , Aorta Torácica/diagnóstico por imagem , Aortografia/métodos , Prótese Vascular , Implante de Prótese Vascular/efeitos adversos , Angiografia por Tomografia Computadorizada , Procedimentos Endovasculares/efeitos adversos , Estudos de Viabilidade , Feminino , Humanos , Embolia Intracraniana/diagnóstico por imagem , Embolia Intracraniana/etiologia , Masculino , Pessoa de Meia-Idade , Tomografia Computadorizada Multidetectores , Fatores de Risco , Procedimentos Cirúrgicos Robóticos/efeitos adversos , Stents , Fatores de Tempo , Resultado do Tratamento , Ultrassonografia Doppler Transcraniana
6.
Clin Radiol ; 72(9): 795.e1-795.e5, 2017 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-28522259

RESUMO

AIM: To investigate the effect of playing computer games and manual dexterity on catheter-wire manipulation in a mechanical aortic model. MATERIAL AND METHODS: Medical student volunteers filled in a preprocedure questionnaire assessing their exposure to computer games. Their manual dexterity was measured using a smartphone game. They were then shown a video clip demonstrating renal artery cannulation and were asked to reproduce this. All attempts were timed. Two-tailed Student's t-test was used to compare continuous data, while Fisher's exact test was used for categorical data. RESULTS: Fifty students aged 18-22 years took part in the study. Forty-six completed the task at an average of 168 seconds (range 103-301 seconds). There was no significant difference in the dexterity score or time to cannulate the renal artery between male and female students. Students who played computer games for >10 hours per week had better dexterity scores than those who did not play computer games: 9.1 versus 10.2 seconds (p=0.0237). Four of 19 students who did not play computer games failed to complete the task, while all of those who played computer games regularly completed the task (p=0.0168). CONCLUSION: Playing computer games is associated with better manual dexterity and ability to complete a basic interventional radiology task for novices.


Assuntos
Cateterismo/instrumentação , Simulação por Computador , Desempenho Psicomotor/fisiologia , Artéria Renal , Estudantes de Medicina , Jogos de Vídeo , Adolescente , Competência Clínica , Feminino , Humanos , Masculino , Smartphone , Inquéritos e Questionários , Análise e Desempenho de Tarefas , Adulto Jovem
7.
Vascular ; 25(3): 266-271, 2017 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-27688294

RESUMO

Purpose The aim of this paper is to report our experience of type II endoleak treatment after endovascular aneurysm repair with intra-arterial injection of the embolizing liquid material, Onyx liquid embolic system. Methods From 2005 to 2012, we performed a retrospective review of 600 patients, who underwent endovascular repair of an abdominal aortic aneurysm. During this period, 18 patients were treated with Onyx for type II endoleaks. Principal findings The source of the endoleak was the internal iliac artery in seven cases, inferior mesenteric artery in seven cases and lumbar arteries in four cases. Immediate technical success was achieved in all patients and no endoleak from the treated vessel recurred. During a mean follow-up of 19 months, no major morbidity or mortality occurred, and one-year survival was 100%. Conclusions Treatment of type II endoleaks with Onyx is safe and effective over a significant time period.


Assuntos
Aneurisma da Aorta Abdominal/cirurgia , Implante de Prótese Vascular/efeitos adversos , Dimetil Sulfóxido/administração & dosagem , Embolização Terapêutica/métodos , Endoleak/terapia , Procedimentos Endovasculares/efeitos adversos , Artéria Ilíaca , Vértebras Lombares/irrigação sanguínea , Artéria Mesentérica Inferior , Polivinil/administração & dosagem , Tantálio/administração & dosagem , Idoso , Idoso de 80 Anos ou mais , Angiografia Digital , Angiografia por Tomografia Computadorizada , Dimetil Sulfóxido/efeitos adversos , Combinação de Medicamentos , Embolização Terapêutica/efeitos adversos , Endoleak/diagnóstico por imagem , Endoleak/etiologia , Feminino , Humanos , Artéria Ilíaca/diagnóstico por imagem , Injeções Intra-Arteriais , Masculino , Artéria Mesentérica Inferior/diagnóstico por imagem , Polivinil/efeitos adversos , Estudos Retrospectivos , Tantálio/efeitos adversos , Fatores de Tempo , Resultado do Tratamento
9.
Am J Transplant ; 14(1): 133-43, 2014 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-24354873

RESUMO

In this study, we analyze the outcomes of transplant renal artery stenosis (TRAS), determine the different anatomical positions of TRAS, and establish cardiovascular and immunological risk factors associated with its development. One hundred thirty-seven of 999 (13.7%) patients had TRAS diagnosed by angiography; 119/137 (86.9%) were treated with angioplasty, of which 113/137 (82.5%) were stented. Allograft survival in the TRAS+ intervention, TRAS+ nonintervention and TRAS- groups was 80.4%, 71.3% and 83.1%, respectively. There was no difference in allograft survival between the TRAS+ intervention and TRAS- groups, p = 0.12; there was a difference in allograft survival between the TRAS- and TRAS+ nonintervention groups, p < 0.001, and between the TRAS+ intervention and TRAS+ nonintervention groups, p = 0.037. TRAS developed at the anastomosis, within a bend/kink or distally. Anastomotic TRAS developed in living donor recipients; postanastomotic TRAS (TRAS-P) developed in diabetic and older patients who received grafts from deceased, older donors. Compared with the TRAS- group, patients with TRAS-P were more likely to have had rejection with arteritis, odds ratio (OR): 4.83 (1.47-15.87), p = 0.0095, and capillaritis, OR: 3.03 (1.10-8.36), p = 0.033. Patients with TRAS-P were more likely to have developed de novo class II DSA compared with TRAS- patients hazard ratio: 4.41 (2.0-9.73), p < 0.001. TRAS is a heterogeneous condition with TRAS-P having both alloimmune and traditional cardiovascular risk factors.


Assuntos
Anticorpos/análise , Antígenos de Histocompatibilidade Classe II/imunologia , Transplante de Rim/efeitos adversos , Obstrução da Artéria Renal/imunologia , Doadores de Tecidos , Adulto , Idoso , Angiografia Digital/efeitos adversos , Feminino , Rejeição de Enxerto/etiologia , Sobrevivência de Enxerto , Humanos , Masculino , Pessoa de Meia-Idade , Obstrução da Artéria Renal/diagnóstico , Obstrução da Artéria Renal/cirurgia , Fatores de Risco , Stents , Resultado do Tratamento
10.
Eur J Vasc Endovasc Surg ; 47(1): 19-26, 2014 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-24183250

RESUMO

OBJECTIVE: Evaluation of variation in descending thoracic aortic aneurysm (dTAA) diameters measured on CT scans in different planes and by different observers and the potential impact on treatment decisions. METHODS: CT angiography of dTAA (N = 20) were assessed by three specialists, with measurements repeated after 1 month. Calliper measurements of maximum external diameters were made on unformatted images and perpendicular to the aneurysm centerline after image processing (corrected). Repeatability was assessed using Bland-Altman plots. RESULTS: Maximum corrected diameter measurements were smaller than axial measurements (66.3 ± 7.9 mm vs. 74.9 ± 20.9 mm, p < .001). Both intraobserver and interobserver variation were less for corrected than for axial measurements (mean intraobserver differences 5.0 ± 3.8 mm vs. 11.8 ± 9.3 mm, p < .001; mean interobserver differences 2.8 ± 2.5 mm versus 10.4 ± 14.0 mm, p < .001) and interobserver variation increased with aneurysm diameter for maximum axial but not corrected measurements. Using corrected rather than axial measurements could have changed treatment decisions in two patients (10%) using a treatment threshold diameter of 55 mm and 10 patients (50%) using a threshold of 65 mm. CONCLUSION: Corrected diameters were smaller than axial diameters, could be measured with higher repeatability, and were subject to less interobserver variability. Using corrected versus axial measurements would have changed management decisions in up to half of the cases in this study.


Assuntos
Aorta Torácica/diagnóstico por imagem , Aneurisma da Aorta Torácica/diagnóstico por imagem , Aortografia/métodos , Tomografia Computadorizada Multidetectores , Interpretação de Imagem Radiográfica Assistida por Computador , Análise de Variância , Aneurisma da Aorta Torácica/terapia , Humanos , Variações Dependentes do Observador , Valor Preditivo dos Testes , Prognóstico , Reprodutibilidade dos Testes
11.
Eur J Vasc Endovasc Surg ; 45(5): 509-15, 2013 May.
Artigo em Inglês | MEDLINE | ID: mdl-23465454

RESUMO

OBJECTIVES: Accurate assessment and credentialing of physicians is essential. Objective motion analysis of guide-wire/catheter manipulation to assess proficiency during endovascular interventions remains unexplored. This study aims to assess its feasibility and its role in evaluation of technical ability. MATERIALS AND METHODS: A semi-automated catheter-tracking software was developed which allows for frame-by-frame motion analysis of fluoroscopic videos and calculation 2D catheter tip path-length. 21 interventionalists (6 cardiologists, 8 interventional radiologists, 7 vascular surgeons; 14/21 had performed >500 endovascular procedures) performed an identical carotid artery stenting procedure (CAS) on a VIST simulator (Mentice, Gothenburg, Sweden). Operators were sub-divided into four categories according to CAS experience: 6 inexperienced (0 CAS-group A), 3 low-volume (1-20 CAS-group B), 5 moderate-volume (21-50 CAS-group C) and 7 high-volume (>50 CAS-group D) CAS experience. Total PL was calculated for each case and comparisons made between groups. PL was correlated with: quantitative, simulator-derived metrics and qualitative performance scores (generic and procedure-specific) derived from post-hoc video analysis by three blinded observers. RESULTS: Group D used 5160.3 (inter-quartile range- IQR 4046.4-7142.9) pixels of movement, compared to 6856.7 (5914.4-8106.9) for group A (p = 0.046); 10,905.1 (7851.1-14,381.5) for group B (p = 0.017); and 9482.6 (8663.5-13,847.6) for group C (p = 0.003). Statistically significant inverse correlations were seen between total PL and qualitative performance scores (rho = -0.519 for generic (p = 0.027) rho = -0.567 for procedure-specific (p = 0.014) scores). PL did not correlate with any of the simulator-derived metrics (errors, contrast volume, total procedure and fluoroscopy times, cine-loops used). CONCLUSION: Endovascular instrument video motion analysis is feasible and may represent a valuable tool for the objective assessment of endovascular skill.


Assuntos
Competência Clínica , Procedimentos Endovasculares/educação , Gravação de Videoteipe , Estudos de Viabilidade , Humanos , Projetos Piloto
12.
Eur J Vasc Endovasc Surg ; 45(3): 248-54, 2013 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-23305790

RESUMO

BACKGROUND: The unique and complex vascular and endovascular theatre environment is associated with significant risks of patient harm and procedural inefficiency. Accurate evaluation is crucial to improve quality. This pilot study attempted to design a valid, reproducible tool for observers and teams to identify and categorise errors. METHODS: Relevant published literature and previously collected ethnographic field notes from over 250 h of arterial surgery were analysed. A comprehensive log of vascular procedural errors was compiled and twelve vascular experts graded each error for the potential to disrupt procedural flow and cause harm. Using this multimodal approach, the Imperial College Error CAPture (ICECAP) tool was developed. The tool was validated during 21 consecutive arterial cases (52 h operating-time) as an observer-led error capture record and as a prompt for surgical teams to determine the feasibility of error self-reporting. RESULTS: Six primary categories (communication, equipment, procedure independent pressures, technical, safety awareness and patient related) and 20 error sub-categories were determined as the most frequent and important vascular procedural errors. Using the ICECAP, the number of errors detected correlated well between two observers (Spearman rho = 0.984, p < 0.001). Both observers identified all moderate or severe errors similarly and categorised all but 4/139 (2.9%) of the total errors in an identical fashion. Self-reporting of errors without prompting identified a mean of 24.4% (range 0-50%) of all recorded errors, whereas surgical teams reported a mean of 69.7% (range 50-100%) of errors when ICECAP error-category prompts were used. CONCLUSION: The ICECAP tool may be useful for capturing and categorising errors that occur during vascular/endovascular procedures. ICECAP may also have a role as an error recall prompt for self-reporting purposes by vascular surgical teams.


Assuntos
Procedimentos Endovasculares/instrumentação , Erros Médicos/prevenção & controle , Avaliação da Tecnologia Biomédica/métodos , Doenças Vasculares/cirurgia , Procedimentos Cirúrgicos Vasculares/instrumentação , Procedimentos Endovasculares/métodos , Humanos , Projetos Piloto , Resultado do Tratamento , Procedimentos Cirúrgicos Vasculares/métodos
13.
J Postgrad Med ; 59(1): 69-75, 2013.
Artigo em Inglês | MEDLINE | ID: mdl-23525067

RESUMO

CONTEXT AND AIMS: Internet use is rapidly expanding and increasingly plays a substantial role in patient education. We sought to evaluate and compare the quality of information available to patients online on three closely linked specialties: Interventional radiology (IR), cardiology, and vascular surgery. MATERIALS AND METHODS: We searched the leading three search engines for the terms: "Interventional Radiology", "cardiology," and "vascular surgery," collating the top 50 hits from each search. After excluding duplicates and irrelevant sites, 43, 25, and 36 sites remained, respectively. Sites were analyzed using the LIDA instrument (an online tool for assessing health-related websites) and Fleisch Reading Ease Scores (FRES) were compared across the different search terms and correlated with the country of origin and certification by the Health on the Net (HON) Foundation. RESULTS: There was no significant difference ( P>0.05) in the total LIDA, accessibility, usability or reliability scores between the three specialties. HONCode certification was associated with higher LIDA (83.1±1.6 vs. 71.53±0.8 ( P<0.0001)), reliability (75.7±3.6 vs. 49.0±1.6 ( P<0.0001)) and FRES (37.4±4.0 vs. 29.7±1.4 ( P=0.0441)). CONCLUSION: Websites are generally well designed and easy to use; the majority however, lacks currency and reliability. Despite similarity in quality of online information, there is a disparity in knowledge of IR; this may be due to low web-traffic figures of IR sites. Wikipedia's user-generated content, ranks highly in major search engines, as such; this could serve as means of disseminating reliable health information to patients.


Assuntos
Cardiologia , Informação de Saúde ao Consumidor/normas , Disseminação de Informação , Internet , Radiologia Intervencionista , Procedimentos Cirúrgicos Vasculares , Humanos , Reprodutibilidade dos Testes , Ferramenta de Busca
15.
Eur J Vasc Endovasc Surg ; 41(2): 175-85, 2011 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-21130007

RESUMO

OBJECTIVE: To determine the proportion of TAAAs which might be suitable for pure endovascular repair based on aneurysm morphology and to develop an MDCTA based scoring system to grade case complexity. DESIGN: 70 consecutive MDCTA of patients with TAAAs were analysed in relation to specific morphological characteristics. METHODS: The characteristics included potential stent landing zone lengths, arch angulation, thoraco-abdominal aorta angulation, branch vessel origin stenosis, access tortuosity/diameter and aortic dissection. RESULTS: 60% of TAAAs would be suitable for branched/fenestrated stent grafting but 40% are unsuitable due to adverse anatomy. 27% had an aortic arch angulation of ≤ 110° and 24% had descending thoracic aorta angulation of ≤ 90°. Significant ostial stenosis was identified in 31% of celiac arteries, 7% superior mesenteric arteries, 24% left renal artery and 19% right renal arteries. 11% of left common iliac and 7% right common iliac arteries had angulation of ≤ 70°. There were 26 cases with aortic dissection and 54% of these had a true lumen of ≤ 26 mm. CONCLUSION: Successful fenestrated/branched stent graft repair of TAAAs requires adequate landing zones, cannulation of visceral arteries and suitable diameter access vessels. 60% of TAAAs studied were suitable for branched/fenestrated stent graft repair but 40% of TAAAs were unsuitable; aortic angulation, visceral vessel ostial stenosis and dissection true lumen diameter were the principle issues. Development in stent technology may address these anatomical challenges.


Assuntos
Aneurisma da Aorta Torácica/diagnóstico por imagem , Aneurisma da Aorta Torácica/cirurgia , Aortografia/métodos , Implante de Prótese Vascular/instrumentação , Prótese Vascular , Técnicas de Apoio para a Decisão , Procedimentos Endovasculares/instrumentação , Stents , Tomografia Computadorizada por Raios X , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Artéria Ilíaca/diagnóstico por imagem , Londres , Masculino , Pessoa de Meia-Idade , Seleção de Pacientes , Valor Preditivo dos Testes , Desenho de Prótese , Estudos Retrospectivos
16.
Eur J Vasc Endovasc Surg ; 42(4): 531-8, 2011 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-21388839

RESUMO

INTRODUCTION: Advanced endovascular procedures require a high degree of skill with a long learning curve. We aimed to identify differential increases in endovascular skill acquisition in novices using conventional (CC), manually steerable (MSC) and robotic endovascular catheters (RC). MATERIALS/METHODS: 10 novices cannulated all vessels within a CT-reconstructed pulsatile-flow arch phantom in the Simulated Endovascular Suite. Subjects were randomly assigned to conventional/manually-steerable/robotic techniques as the first procedure undertaken. The operators repeated the task weekly for 5 weeks. Quantitative (cannulation times, wire/catheter-tip movements, vessel wall hits) and qualitative metrics (validated rating scale (IC3ST)) were compared. RESULTS: Subjects exhibited statistically significant differences when comparing initial to final performance for total procedure times and catheter-tip movements with all catheter types. Sequential non-parametric comparisons identified learning curve plateau levels at weeks 2 or 3(RCs, MSCs), and at week 4(CCs) for the majority of metrics. There were significantly fewer catheter-tip movements using advanced catheter technology after training (Week 5: CC 74 IQR(59-89) versus MSC 62(44-81); p = 0.028, and RC 33 (28-44); p = 0.012). RCs virtually eliminated wall hits at the arch (CC 29(28-76) versus RC 8(6-9); p = 0.005) and produced significantly higher overall performance scores (p < 0.02). CONCLUSION: Advanced endovascular catheters, although more intricate, do not seem to take longer to master and in some areas offer clear advantages with regards to positional control, at a faster rate. RCs seem to be the most intuitive and advanced skill acquisition occurs with minimal training. Robotic endovascular technology may have a significantly shorter path to proficiency allowing an increased number of trainees to attempt more complex endovascular procedures earlier and with a greater degree of safety.


Assuntos
Cateterismo , Procedimentos Endovasculares/educação , Curva de Aprendizado , Robótica , Catéteres , Simulação por Computador , Desenho de Equipamento , Humanos
17.
Eur J Vasc Endovasc Surg ; 41(4): 488-91, 2011 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-21232994

RESUMO

This report describes endovascular stenting of an acute mycotic ascending aortic aneurysm. An eighty-three year old lady presented nine weeks after aortic valve surgery and subsequent thyroidectomy with sternal pain secondary to a mycotic ascending aortic pseudoaneurysm. The pseudoaneurysm was visible through the unhealed sternum. Open repair was considered too high a mortality risk. Endovascular stenting was performed using two covered infrarenal proximal extension devices (GORE Excluder Aortic Extender(®), W. L. Gore & Associates, Flagstaff, Arizona, USA) deployed from a right axillary approach utilising overdrive cardiac pacing. Post procedure imaging revealed shrinkage of the pseudoaneurysm sac.


Assuntos
Falso Aneurisma/cirurgia , Aneurisma Infectado/cirurgia , Aneurisma Aórtico/cirurgia , Implante de Prótese Vascular , Procedimentos Endovasculares , Doença Aguda , Idoso de 80 Anos ou mais , Falso Aneurisma/diagnóstico por imagem , Falso Aneurisma/microbiologia , Aneurisma Infectado/diagnóstico por imagem , Aneurisma Infectado/microbiologia , Angiografia Digital , Antibacterianos/uso terapêutico , Aneurisma Aórtico/diagnóstico por imagem , Aneurisma Aórtico/microbiologia , Valva Aórtica/cirurgia , Aortografia/métodos , Prótese Vascular , Implante de Prótese Vascular/instrumentação , Estimulação Cardíaca Artificial , Procedimentos Endovasculares/instrumentação , Feminino , Implante de Prótese de Valva Cardíaca/efeitos adversos , Humanos , Desenho de Prótese , Staphylococcus aureus/isolamento & purificação , Stents , Tomografia Computadorizada por Raios X , Resultado do Tratamento
18.
Eur J Vasc Endovasc Surg ; 42(3): 340-6, 2011 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-21628100

RESUMO

INTRODUCTION: Splanchnic and renal artery aneurysms (SRAAs) are uncommon but potentially life-threatening in case of rupture. Whether these aneurysms are best treated by open repair or endovascular intervention is unknown. The aim of this retrospective study is to report the results of open and endovascular repairs in two European institutions over a fifteen-year period. We have reviewed the available literature published over the 10 last years. METHODS: All patients with SRAAs diagnosed from 1995 to 2010 in St Marys Hospital (London, UK) and Henri Mondor Hospital (Créteil, France) were reviewed. Preoperative clinical and anatomical data, operative management and outcomes were recorded from the charts and analyzed. RESULTS: 40 patients with 51 SRAAs were identified. There were 21 males and 19 females with a mean age of 57 ± 14.9 years. The aneurysms locations were: 14 (27%) renal, 11 (22%) splenic, 7 (14%) celiac trunk, 7 (14%) superior mesenteric artery, 4 (8%) hepatic, 4 (8%) pancreaticoduodenal arcades, 3 (6%) left gastric and 1 (2%) gastroduodenal. 4 patients presented with a ruptured SRAA. 17 SRAAs in 16 patients were treated by open repair, 15 in 15 patients were treated endoluminally and 17 (mean diameter: 18 mm, range: 8-75 mm) were managed conservatively. One patient with metastatic pulmonary cancer with two mycotic aneurysms of the superior mesenteric artery (75 mm) and celiac trunk (15 mm) was palliated. After endovascular treatment, the immediate technical success rate was 100%. There was no significant difference between open repair and endovascular patients in terms of 30-day post-operative mortality rate and peri-operative complications. No in-hospital death occurred in patients treated electively. Postoperatively, four patients (1 ruptured and 3 elective) suffered non-lethal mild to severe complication in the open repair group, as compared with one in the endovascular group (p = .34). The mean length of stay was significantly higher after open repair as compared with endovascular repair (17 days, range: 8-56 days vs. 4 days, range: 2-6; p < .001). The mean follow-up time was 17.8 months (range: 0-143 months) after open repair, 15.8 months (range: 0-121 months) after endovascular treatment, and 24.8 (range: 3-64 months) for patient being managed conservatively. No late death related to the VAA occurred. In each group, 2 successful reoperations were deemed necessary. In the endovascular group, two patients presented a reperfusion of the aneurysmal sac at 6 and 24 months respectively. CONCLUSION: No significant difference in term of 30-day mortality and post-operative complication rates could be identified between open repair and endovascular treatment in the present series. Endovascular treatment is a safe alternative to open repair but patients are exposed to the risk of aneurysmal reperfusion. This mandates careful long-term imaging follow up in patients treated endoluminally.


Assuntos
Aneurisma/cirurgia , Artéria Renal , Circulação Esplâncnica , Adulto , Idoso , Implante de Prótese Vascular , Procedimentos Endovasculares , Feminino , França , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Reino Unido
19.
J Cardiovasc Surg (Torino) ; 52(3): 353-62, 2011 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-21577190

RESUMO

In recent years, steerable catheter systems have been introduced into clinical practice for cardiac mapping and ablation procedures. As endovascular therapy is becoming more complex, more advanced and versatile catheter designs utilizing robotic technology may have a role in aortic and peripheral arterial interventions. This article discusses alternative steerable catheter designs focusing on robotic endovascular catheter technology. A comprehensive comparison, review and analysis of robotic versus manual techniques in the visceral segment are presented to reveal both their advantages and limitations. Preclinical studies and early experience suggest that robotically steerable endovascular catheters offer improved manoeuvrability at the catheter tip, enhanced positional control and "off-the-wall" centreline navigation in a remote-control fashion. These advanced systems have the potential to overcome some of the technical difficulties with manual catheter control, improve stability at key target areas, reduce the risk of vessel trauma, distal embolization and radiation exposure, whilst improving overall operator performance with short learning curves. Robotic catheter technology may be more suitable to complex and often unpredictable anatomy in the visceral segment and may offer a reliable platform for future applications involving device delivery or target intervention. This intuitive technology is rapidly evolving and still requires technological refinements to extend current capabilities. Clinical studies involving head-to-head comparisons with conventional techniques are essential for evaluating its long-term safety and efficacy.


Assuntos
Aorta , Cateterismo Periférico/instrumentação , Catéteres , Procedimentos Endovasculares/instrumentação , Robótica , Terapia Assistida por Computador/instrumentação , Vísceras/irrigação sanguínea , Artérias , Cateterismo Periférico/efeitos adversos , Catéteres/efeitos adversos , Procedimentos Endovasculares/efeitos adversos , Desenho de Equipamento , Humanos , Radiografia Intervencionista/instrumentação , Medição de Risco , Fatores de Risco
20.
Eur J Vasc Endovasc Surg ; 39(6): 683-90, 2010 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-20227895

RESUMO

BACKGROUND: Aortic arch disease has conventionally been the domain of open surgical repair. Hybrid open and endovascular repair has evolved as an alternative, less invasive, treatment option with promising results. A systematic literature review and analysis of the reported outcomes was undertaken. METHODS: An Internet-based literature search using MEDLINE was performed to identify all studies reporting on hybrid aortic arch repair with supra-aortic branch revascularisation and subsequent stent graft deployment. Debranching should involve at least one carotid artery, so that patients merely requiring a carotid-subclavian bypass were not included. Only reports of five patients or more were included in the analysis. Outcome measures were technical success, perioperative, 30-day and late morbidity and mortality. RESULTS: Eighteen studies fulfilled our search criteria, and data from 195 patients were entered for the analysis. No comparative studies of hybrid aortic arch repair with other conventional or innovative treatment modalities were identified. Complete arch repair was performed in 122 patients (63%). The overall technical success rate was 86% (167/195). The most common reason for technical failure was endoleak (9%, 17/195). Overall perioperative morbidity and mortality rates were 21% (41/195) and 9% (18/195), respectively. The most common perioperative complication was stroke (7%, 14/195). Four aneurysm-related deaths were reported during follow-up (2%). No long-term data on hybrid aortic arch repair were identified. CONCLUSIONS: Hybrid repair of complex aortic arch disease is an alternative treatment option with acceptable short-term results. Stroke remains a frequent complication and mortality rates are significant. Further research with large comparative studies and longer follow-up is required.


Assuntos
Aorta Torácica/cirurgia , Síndromes do Arco Aórtico/cirurgia , Implante de Prótese Vascular/métodos , Stents , Humanos , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA