1.
J Vasc Surg ; 59(1): 96-106, 2014 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-24094903

RESUMO

INTRODUCTION: Despite a current lack of U.S. Food and Drug Administration approval for the indication, thoracic endovascular aortic repair (TEVAR) has replaced open surgical management for acute complicated type B aortic dissection due to promising short- and midterm data. However, long-term results, with a view toward durability and need for secondary procedures, are limited. As such, the objective of the present study is to report long-term outcomes of TEVAR for acute (≤ 2 weeks from symptom onset) complicated type B dissection. METHODS: Between July 2005 and September 2012, 50 consecutive patients underwent TEVAR for management of acute complicated type B dissection at a single referral institution. Patient records were retrospectively reviewed from a prospectively maintained clinical database. RESULTS: Indications for intervention included rupture in 10 (20%), malperfusion in 24 (48%), and/or refractory pain/impending rupture in 17 (34%). One patient (2%) had both rupture and malperfusion indications. Ten (20%) patients required one or more adjunctive procedures, in addition to TEVAR, to treat malperfusion syndromes. In-hospital and 30-day rates of death were both 0%; 30-day/in-hospital rates of stroke, permanent paraplegia/paraparesis, and new-onset dialysis were 2% (n = 1), 2% (n = 1), and 4% (n = 2), respectively. Median follow-up was 33.8 months [interquartile range, 12.3-56.6 months]. Overall survival at 5 and 7 years was 84%, with no deaths attributable to aortic pathology. Thirteen (26%) patients required a total of 17 reinterventions over the study period for type I endoleak (n = 5), metachronous aortic pathology (n = 5), persistent false lumen pressurization via distal fenestrations (n = 4), type II endoleak (n = 2), or retrograde acute type A aortic dissection (n = 1). Median time to first reintervention was 4.5 months (range, 0 days-40.3 months). Of the 17 total reinterventions, six (35%) were performed using open techniques and 11 (65%) with endovascular or hybrid methods; there was no difference in survival between patients who did or did not require reintervention. CONCLUSIONS: This study confirms the excellent short-term outcomes of TEVAR for acute complicated type B dissection and demonstrates the results to be durable and sustained over long-term follow-up. Although aortic reinterventions were required in one-quarter of patients, no aortic-related deaths were observed. These data support the use of TEVAR for acute complicated type B aortic dissection but also highlight the importance of life-long aortic surveillance by an experienced aortic referral center in order to identify and treat complications of the underlying disease process and treatment, as well as new aortic pathologies, as they arise.


Assuntos
Aneurisma da Aorta Torácica/cirurgia , Dissecção Aórtica/cirurgia , Ruptura Aórtica/cirurgia , Implante de Prótese Vascular , Procedimentos Endovasculares , Doença Aguda , Idoso , Dissecção Aórtica/diagnóstico por imagem , Dissecção Aórtica/mortalidade , Aneurisma da Aorta Torácica/diagnóstico por imagem , Aneurisma da Aorta Torácica/mortalidade , Ruptura Aórtica/diagnóstico por imagem , Ruptura Aórtica/mortalidade , Aortografia/métodos , Implante de Prótese Vascular/efeitos adversos , Implante de Prótese Vascular/mortalidade , Procedimentos Endovasculares/efeitos adversos , Procedimentos Endovasculares/mortalidade , Feminino , Mortalidade Hospitalar , Humanos , Estimativa de Kaplan-Meier , Masculino , Pessoa de Meia-Idade , North Carolina , Complicações Pós-Operatórias/mortalidade , Complicações Pós-Operatórias/terapia , Estudos Retrospectivos , Centros de Atenção Terciária , Fatores de Tempo , Tomografia Computadorizada por Raios X , Resultado do Tratamento
2.
J Vasc Surg ; 59(4): 921-9, 2014 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-24360582

RESUMO

OBJECTIVE: Type I attachment site endoleaks are the most common cause for reintervention after thoracic endovascular aortic repair (TEVAR) and represent treatment failures. Deployment of endografts in segments of the aorta previously replaced with Dacron grafts may be associated with reduced type I endoleak due to mechanical stability and decreased potential for aortic remodeling. However, no study has rigorously examined endoleak rates in Dacron landing zones vs native aorta. METHODS: A retrospective analysis of a prospectively maintained database was performed to identify all patients undergoing TEVAR at a single referral institution between May 2002 and June 2012. Overall, 319 patients undergoing 345 procedures had at least one follow-up contrast-enhanced computed tomography scan to assess for postoperative type I endoleak. Attachment site landing zones were classified as native aorta, Dacron, or endograft if landed in a previously placed endograft. Patient characteristics and type I endoleak rates were compared among the three groups. RESULTS: Identified were 697 proximal or distal landing zones (native aorta, 599; Dacron, 79; and endograft, 19). Patients with at least one Dacron landing zone had higher rates of hypertension (P < .01), chronic obstructive pulmonary disease (P = .04), and prior aortic surgery (P < .01) and were more likely to have undergone complex hybrid repairs (P < .01). Cumulative type I endoleak rates were equivalent between the three types of landing zone (native aorta, 3.7%; Dacron, 2.5%; endograft, 0%; P = .44). Two type I endoleaks occurred with Dacron landing zones in the first tertile of TEVAR experience and with Dacron landing zone lengths of <2.5 cm. Evaluation of endoleak rates by tertile of experience demonstrated decreased type I endoleak rates in Dacron landing zones between the first and second/third tertiles of experience (13.3% vs 0%, P = .03) after a policy of using >4 to 5 cm (twice the device instructions for use) of Dacron overlap was initiated. CONCLUSIONS: Endograft deployment within long-segment (landing zone length of >4-5 cm) Dacron represents a durable option for aortic repair and was associated with a 0% rate of type I endoleak. In cases of a borderline native aortic landing zone, a hybrid procedure to create an adequate Dacron landing zone may be warranted to decrease the risk of type I endoleak and treatment failure.


Assuntos
Aneurisma da Aorta Torácica/cirurgia , Implante de Prótese Vascular , Prótese Vascular , Endoleak/prevenção & controle , Polietilenotereftalatos , Idoso , Aneurisma da Aorta Torácica/diagnóstico , Aortografia/métodos , Implante de Prótese Vascular/efeitos adversos , Implante de Prótese Vascular/instrumentação , Implante de Prótese Vascular/métodos , Intervalo Livre de Doença , Endoleak/diagnóstico , Endoleak/etiologia , Feminino , Humanos , Estimativa de Kaplan-Meier , Masculino , Pessoa de Meia-Idade , North Carolina , Desenho de Prótese , Reoperação , Estudos Retrospectivos , Fatores de Risco , Fatores de Tempo , Tomografia Computadorizada por Raios X , Falha de Tratamento
3.
Curr Opin Urol ; 24(4): 382-8, 2014 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-24841377

RESUMO

PURPOSE OF REVIEW: Iatrogenic rectourethral fistulas (RUFs) are a rare but challenging complication that can follow the treatment of prostate cancer. We review the literature regarding the surgical management of RUFs and subsequent outcomes, focusing on a cause-specific approach. RECENT FINDINGS: Iatrogenic RUFs are reported to occur in approximately 1% of patients treated with external-beam radiation therapy, in 1-6% of patients after radical prostatectomy, and in 5-9% following brachytherapy or cryotherapy after prostate cancer. Most of these patients will require surgical treatment at some point. Though there have been multiple surgical procedures described with varying degrees of success, there is no consensus as to the procedure of choice, though authors now agree on the importance of the interposition of healthy tissue in radiation-induced fistulas. SUMMARY: The current literature regarding surgical approaches to the iatrogenic RUF in the prostate cancer patient highlights the importance of a cause-specific and often multidisciplinary approach, as well as the one that is most familiar to the individual surgeon, because there is often little difference in the approaches in terms of recurrence. However, given the high success rate and low complication rate, muscle transposition flap repairs remain an attractive surgical option for fistulas with unfavorable local conditions such as those present after radiation.


Assuntos
Adenocarcinoma/radioterapia , Neoplasias da Próstata/radioterapia , Radioterapia/efeitos adversos , Fístula Retal/etiologia , Doenças Uretrais/etiologia , Fístula Urinária/etiologia , Adenocarcinoma/cirurgia , Humanos , Doença Iatrogênica , Masculino , Neoplasias da Próstata/cirurgia , Fístula Retal/cirurgia , Doenças Uretrais/cirurgia , Fístula Urinária/cirurgia
4.
Dis Colon Rectum ; 57(9): 1105-12, 2014 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-25101607

RESUMO

BACKGROUND: Rectourethral fistulas are an uncommon, yet devastating occurrence after treatment for prostate cancer or trauma, and their surgical management has historically been nonstandardized. Anecdotally, irradiated rectourethral fistulas portend a worse prognosis. OBJECTIVE: To review outcomes after surgical treatment of rectourethral fistulas in radiated and nonirradiated patients to construct a logical surgical algorithm. DESIGN AND SETTING: A retrospective review was undertaken of all patients presenting to Duke University with the diagnosis of rectourethral fistula from 1996 to 2012. PATIENTS: Thirty-seven patients presented with and were treated for rectourethral fistulas: 21 received radiation, and a rectourethral fistula from trauma or iatrogenic injury developed in 16. MAIN OUTCOME MEASURES: The groups were compared regarding their functional outcomes, including healing, time to healing, continence, and recurrence. RESULTS: There were no significant differences in patient characteristics between groups. Patients who had irradiated rectourethral fistulas had a significantly higher rate of passage of urine through the rectum and wound infections, a higher rate of crystalloid infusion and blood transfusion requirements, and a longer time to ostomy reversal than nonirradiated patients. Patients who had irradiated rectourethral fistulas underwent more complex operative repairs, including gracilis interposition flaps (38%) and pelvic exenterations (19%), whereas nonirradiated patients most commonly underwent a York-Mason repair (50%). There were no statistically significant differences in rectourethral fistula healing or in postoperative and functional outcomes. Only 55% of irradiated patients had their ostomy reversed versus 91% in the nonirradiated group. LIMITATIONS: This study was limited by the small sample size and the retrospective nature of the review. CONCLUSIONS: Repair of rectourethral fistulas caused by radiation has a significantly higher wound infection rate and median time to healing, and lower overall stomal reversal rate than nonradiation-induced rectourethral fistulas. Patients who had irradiated rectourethral fistulas required significantly more complex operations, likely contributing to the higher morbidity, mortality, and lower fistula closure rate. We propose an algorithm for approaching rectourethral fistulas based on etiology.


Assuntos
Neoplasias da Próstata/radioterapia , Fístula Retal/cirurgia , Doenças Uretrais/cirurgia , Fístula Urinária/cirurgia , Adulto , Idoso , Algoritmos , Comorbidade , Humanos , Masculino , Pessoa de Meia-Idade , Fístula Retal/etiologia , Estudos Retrospectivos , Fatores de Risco , Retalhos Cirúrgicos , Resultado do Tratamento , Doenças Uretrais/etiologia , Fístula Urinária/etiologia
5.
J Vasc Surg ; 57(4): 915-25, 2013 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-23375432

RESUMO

OBJECTIVE: Intrathoracic subclavian artery aneurysms (SAAs) are rare aneurysms that often occur in association with congenital aortic arch anomalies and/or concomitant thoracic aortic pathology. The advent of thoracic endovascular aortic repair (TEVAR) methods may complement or replace conventional open SAA repair. Herein, we describe our experience with SAA repair in the TEVAR era. METHODS: A retrospective review was performed of all intrathoracic SAAs repaired at a single institution since United States Food and Drug Administration approval of TEVAR in 2005. RESULTS: Nineteen patients underwent 20 operations to repair 22 (13 native, nine aberrant) SAAs with an intrathoracic component. Mean SAA diameter was 3.1 cm (range, 1.6-6.0 cm). Mean patient age was 57 years (range, 24-80 years). Twenty-one percent (n = 4) of patients had a connective tissue disorder (two Loeys-Dietz, two Marfan). Thirty-six percent (n = 8) of SAAs were repaired by open techniques and 64% (n = 14) via a TEVAR-based approach. All TEVAR cases required proximal landing zone in the aortic arch (zone 0-2), and revascularization of at least one arch vessel was required in 83% (10/12) of patients. Concomitant repair of associated aortic pathology was performed in 50% (n = 10) of operations. Thirty-day/in-hospital rates of death, stroke, and permanent paraplegia/paraparesis were 5% (n = 1), 5% (n = 1), and 0%, respectively. Over mean (standard deviation) follow-up of 24 (21) months, 16% (n = 3) of patients required reintervention for subclavian artery bypass graft revision (n = 2) or type II endoleak (n = 1). CONCLUSIONS: This is the largest single-institution series to date of TEVAR for SAA repair. Modern endovascular techniques expand SAA repair options with excellent results. The majority of SAAs and nearly all aberrant SAAs (Kommerell's diverticulum) can now be repaired using a TEVAR-based approach without the need for sternotomy or thoracotomy.


Assuntos
Aneurisma/cirurgia , Aorta Torácica/cirurgia , Doenças da Aorta/cirurgia , Implante de Prótese Vascular , Procedimentos Endovasculares , Artéria Subclávia/cirurgia , Adulto , Idoso , Idoso de 80 Anos ou mais , Aneurisma/diagnóstico por imagem , Aneurisma/mortalidade , Aorta Torácica/anormalidades , Aorta Torácica/diagnóstico por imagem , Doenças da Aorta/diagnóstico por imagem , Doenças da Aorta/mortalidade , Aortografia/métodos , Implante de Prótese Vascular/efeitos adversos , Implante de Prótese Vascular/mortalidade , Distribuição de Qui-Quadrado , Endoleak/etiologia , Endoleak/cirurgia , Procedimentos Endovasculares/efeitos adversos , Procedimentos Endovasculares/mortalidade , Feminino , Mortalidade Hospitalar , Humanos , Estimativa de Kaplan-Meier , Masculino , Pessoa de Meia-Idade , North Carolina , Paraparesia/etiologia , Paraplegia/etiologia , Sistema de Registros , Reoperação , Estudos Retrospectivos , Acidente Vascular Cerebral/etiologia , Artéria Subclávia/anormalidades , Artéria Subclávia/diagnóstico por imagem , Fatores de Tempo , Tomografia Computadorizada por Raios X , Resultado do Tratamento , Adulto Jovem
6.
J Vasc Surg ; 57(3): 655-67; discussion 666-7, 2013 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-23186868

RESUMO

OBJECTIVE: Hybrid repair of the transverse aortic arch may allow for aortic arch repair with reduced morbidity in patients who are suboptimal candidates for conventional open surgery. We present our results with an algorithmic approach to hybrid arch repair, based on the extent of aortic disease and patient comorbidities. METHODS: Between August 2005 and January 2012, 87 patients underwent hybrid arch repair by three principal procedures: zone 1 endograft coverage with extra-anatomic left carotid revascularization (zone 1; n = 19), zone 0 endograft coverage with aortic arch debranching (zone 0; n = 48), or total arch replacement with staged stented elephant trunk completion (stented elephant trunk; n = 20). RESULTS: The mean patient age was 64 years, and the mean expected in-hospital mortality rate was 16.3% as calculated by the EuroSCORE II. Of operations, 22% (n = 19) were nonelective. Sternotomy, cardiopulmonary bypass, and deep hypothermic circulatory arrest were required in 78% (n = 68), 45% (n = 39), and 31% (n = 27) of patients to allow for total arch replacement, arch debranching, or other concomitant cardiac procedures, including ascending with or without hemiarch replacement in 17% (n = 8) of patients undergoing zone 0 repair. All stented elephant trunk procedures (n = 20) and 19% (n = 9) of zone 0 procedures were staged, with 41% (n = 12) of patients undergoing staged repair during a single hospitalization. The 30-day/in-hospital rates of stroke and permanent paraplegia or paraparesis were 4.6% (n = 4) and 1.2% (n = 1). Of 27 patients with native ascending aorta zone 0 proximal landing zone, three (11.1%) experienced retrograde type A dissection after endograft placement. The overall in-hospital mortality rate was 5.7% (n = 5); however, 30-day/in-hospital mortality increased to 14.9% (n = 13) owing to eight 30-day out-of-hospital deaths. Native ascending aorta zone 0 endograft placement was found to be the only univariate predictor of 30-day in-hospital mortality (odds ratio, 4.63; 95% confidence interval, 1.35-15.89; P = .02). Over a mean follow-up period of 28.5 ± 22.2 months, 13% (n = 11) of patients required reintervention for type 1A (n = 4), type 2 (n = 6), or type 3 (n = 1) endoleak. Kaplan-Meier estimates of survival at 1 year, 3 years, and 5 years were 73%, 60%, and 51%. CONCLUSIONS: Hybrid aortic arch repair can be tailored to patient anatomy and comorbid status to allow complete repair of aortic pathology, frequently in a single stage, with acceptable outcomes. However, endograft placement in the native ascending aorta is associated with high rates of retrograde type A dissection and 30-day/in-hospital mortality and should be approached with caution.


Assuntos
Algoritmos , Aorta Torácica/cirurgia , Aneurisma da Aorta Torácica/cirurgia , Dissecção Aórtica/cirurgia , Implante de Prótese Vascular , Técnicas de Apoio para a Decisão , Procedimentos Endovasculares , Idoso , Idoso de 80 Anos ou mais , Dissecção Aórtica/diagnóstico , Dissecção Aórtica/mortalidade , Aneurisma da Aorta Torácica/diagnóstico , Aneurisma da Aorta Torácica/mortalidade , Implante de Prótese Vascular/efeitos adversos , Implante de Prótese Vascular/mortalidade , Ponte Cardiopulmonar , Distribuição de Qui-Quadrado , Parada Circulatória Induzida por Hipotermia Profunda , Comorbidade , Endoleak/etiologia , Procedimentos Endovasculares/efeitos adversos , Procedimentos Endovasculares/mortalidade , Feminino , Mortalidade Hospitalar , Humanos , Estimativa de Kaplan-Meier , Masculino , Pessoa de Meia-Idade , Razão de Chances , Paraparesia/etiologia , Paraplegia/etiologia , Reoperação , Medição de Risco , Fatores de Risco , Esternotomia , Acidente Vascular Cerebral/etiologia , Fatores de Tempo , Resultado do Tratamento
7.
J Carcinog ; 12: 6, 2013.
Artigo em Inglês | MEDLINE | ID: mdl-23599688

RESUMO

Lung cancer is the leading cause of cancer deaths worldwide, and current therapies are disappointing. Elucidation of the cell(s) of origin of lung cancer may lead to new therapeutics. In addition, the discovery of putative cancer-initiating cells with stem cell properties in solid tumors has emerged as an important area of cancer research that may explain the resistance of these tumors to currently available therapeutics. Progress in our understanding of normal tissue stem cells, tumor cell of origin, and cancer stem cells has been hampered by the heterogeneity of the disease, the lack of good in vivo transplantation models to assess stem cell behavior, and an overall incomplete understanding of the epithelial stem cell hierarchy. As such, a systematic computerized literature search of the MEDLINE database was used to identify articles discussing current knowledge about normal lung and lung cancer stem cells or progenitor cells. In this review, we discuss what is currently known about the role of cancer-initiating cells and normal stem cells in the development of lung tumors.

8.
J Vasc Surg ; 56(3): 621-9, 2012 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-22575483

RESUMO

OBJECTIVE: Thoracoabdominal aortic aneurysms (TAAAs) occur most commonly in elderly individuals, who are often suboptimal candidates for open repair because of significant comorbidities. The availability of a hybrid option, including open visceral debranching with endovascular aneurysm exclusion, may have advantages in these patients who are at high-risk for conventional repair. This report details the evolution of our technique and results with complete visceral debranching and endovascular aneurysm exclusion for TAAA repair in high-risk patients. METHODS: Between March 2005 and June 2011, 47 patients (51% women) underwent extra-anatomic debranching of all visceral vessels, followed by aneurysm exclusion by endovascular means at a single institution. A median of four visceral vessels were bypassed. The debranching procedure was initially performed through a partial right medial visceral rotation approach, leaving the left kidney posterior in the first 22 patients, and in the last 25 by a direct anterior approach to the visceral vessels. The debranching and endovascular portions of the procedure were performed in a single operation in the initial 33 patients and as a staged procedure during a single hospital stay in the most recent 14. RESULTS: Median patient age was 71.0 ± 9.8 years. All had significant comorbidity and were considered suboptimal candidates for conventional repair: 55% had undergone previous aortic surgery, 40% were American Society of Anesthesiologists (ASA) class 4, and baseline serum creatinine was 1.5 ± 1.3 mg/dL. The 30-day/in-hospital rates of death, stroke, and permanent paraparesis/plegia were 8.5%, 0%, and 4.3%, respectively, but 0% in the most recent 14 patients undergoing staged repair. These patients had significantly shorter combined operative times (314 vs 373 minutes), decreased intraoperative red blood cell transfusions (350 vs 1400 mL), and were more likely to be extubated in the operating room (50% vs 12%) compared with patients undergoing simultaneous repair. Over a median follow-up of 19.3 ± 18.5 months, visceral graft patency was 97%; all occluded limbs were to renal vessels and clinically silent. There have been no type I or III endoleaks or reinterventions. Kaplan-Meier overall survival is 70.7% at 2 years and 57.9% at 5 years. CONCLUSIONS: Hybrid TAAA repair through complete visceral debranching and endovascular aneurysm exclusion is a good option for elderly high-risk patients less suited to conventional repair in centers with the requisite surgical expertise with visceral revascularization. A staged approach to debranching and endovascular aneurysm exclusion during a single hospitalization appears to yield optimal results.


Assuntos
Aneurisma da Aorta Torácica/cirurgia , Implante de Prótese Vascular/métodos , Procedimentos Endovasculares , Idoso , Idoso de 80 Anos ou mais , Aneurisma da Aorta Torácica/diagnóstico por imagem , Aneurisma da Aorta Torácica/mortalidade , Aortografia/métodos , Implante de Prótese Vascular/efeitos adversos , Implante de Prótese Vascular/mortalidade , Distribuição de Qui-Quadrado , Comorbidade , Procedimentos Endovasculares/efeitos adversos , Procedimentos Endovasculares/mortalidade , Feminino , Mortalidade Hospitalar , Humanos , Estimativa de Kaplan-Meier , Modelos Logísticos , Masculino , Pessoa de Meia-Idade , Análise Multivariada , North Carolina , Razão de Chances , Complicações Pós-Operatórias/etiologia , Complicações Pós-Operatórias/mortalidade , Estudos Prospectivos , Sistema de Registros , Medição de Risco , Fatores de Risco , Fatores de Tempo , Tomografia Computadorizada por Raios X , Resultado do Tratamento
9.
J Thorac Cardiovasc Surg ; 151(2): 376-82, 2016 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-26428473

RESUMO

OBJECTIVE: Human fibrinogen concentrate (HFC) is approved by the Food and Drug Administration for use at 70 mg/kg to treat congenital afibrinogenemia. We sought to determine whether this dose of HFC increases fibrinogen levels in the setting of high-risk bleeding associated with aortic reconstruction and deep hypothermic circulatory arrest (DHCA). METHODS: This was a prospective, pilot, off-label study in which 22 patients undergoing elective proximal aortic reconstruction with DHCA were administered 70 mg/kg HFC upon separation from cardiopulmonary bypass (CPB). Fibrinogen levels were measured at baseline, just before, and 10 minutes after HFC administration, on skin closure, and the day after surgery. The primary study outcome was the difference in fibrinogen level immediately after separation from CPB, when HFC was administered, and the fibrinogen level 10 minutes following HFC administration. Additionally, postoperative thromboembolic events were assessed as a safety analysis. RESULTS: The mean baseline fibrinogen level was 317 ± 49 mg/dL and fell to 235 ± 39 mg/dL just before separation from CPB. After HFC administration, the fibrinogen level rose to 331 ± 41 mg/dL (P < .001) and averaged 372 ± 45 mg/dL the next day. No postoperative thromboembolic complications occurred. CONCLUSIONS: Administration of 70 mg/kg HFC upon separation from CPB raises fibrinogen levels by approximately 100 mg/dL without an apparent increase in thrombotic complications during proximal aortic reconstruction with DHCA. Further prospective study in a larger cohort of patients will be needed to definitively determine the safety and evaluate the efficacy of HFC as a hemostatic adjunct during these procedures.


Assuntos
Aorta/cirurgia , Implante de Prótese Vascular , Parada Circulatória Induzida por Hipotermia Profunda , Fibrinogênio/administração & dosagem , Hemostáticos/administração & dosagem , Procedimentos de Cirurgia Plástica , Adulto , Perda Sanguínea Cirúrgica/prevenção & controle , Transfusão de Sangue , Implante de Prótese Vascular/efeitos adversos , Parada Circulatória Induzida por Hipotermia Profunda/efeitos adversos , Procedimentos Cirúrgicos Eletivos , Feminino , Fibrinogênio/efeitos adversos , Hemostáticos/efeitos adversos , Humanos , Masculino , Pessoa de Meia-Idade , North Carolina , Projetos Piloto , Hemorragia Pós-Operatória/prevenção & controle , Estudos Prospectivos , Procedimentos de Cirurgia Plástica/efeitos adversos , Fatores de Tempo , Resultado do Tratamento
10.
Ann Thorac Surg ; 99(1): 265-9, 2015 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-25440285

RESUMO

BACKGROUND: Analyses of adequacy of lymph node dissection during resection of esophageal cancer are based on patients who have not undergone induction chemoradiotherapy. We sought to determine the minimum number of dissected lymph nodes necessary to ensure adequate staging after induction chemoradiotherapy. METHODS: A prospectively maintained thoracic surgery database was queried to identify consecutive patients undergoing postinduction esophagectomy from 1996 to 2010. Cox proportional hazard and recursive partitioning survival analyses were performed. RESULTS: Complete lymph node data were available for 395 patients. Mean age was 59.5 years, and 64 patients (16%) were female. The median number of dissected lymph nodes was 8 (range, 0 to 63). When pathologic (p)T stage, pN stage, and the number of dissected lymph nodes were used as predictors, only pN stage (odds ratio, 1.3; 95% confidence interval, 1.2 to 1.7) and age (odds ratio, 1.03; 95% confidence interval, 1.01 to 1.04) independently predicted survival. Recursive partitioning was performed on 262 pN0 patients using T stage and the number of dissected lymph nodes as predictors. No pN0 patient with 28 lymph nodes dissected died during follow-up. For patients with fewer than 28 lymph nodes dissected, the next prognostic factor was T stage. For pT1-2 N0 patients, the number of lymph nodes dissected did not affect survival. For pT3-4 N0 patients, a significant survival decrement was noted for patients with fewer than 7 lymph nodes dissected compared with those with more than 7 lymph nodes dissected. CONCLUSIONS: T stage determines prognosis in postinduction pN0 patients with fewer than 28 lymph nodes evaluated. Postinduction pT3N0 patients with fewer than 7 lymph nodes evaluated are understaged.


Assuntos
Neoplasias Esofágicas/terapia , Excisão de Linfonodo , Quimiorradioterapia , Feminino , Humanos , Linfonodos/patologia , Masculino , Pessoa de Meia-Idade , Prognóstico , Estudos Retrospectivos
11.
Ann Thorac Surg ; 99(4): 1275-81, 2015 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-25678502

RESUMO

BACKGROUND: Loeys-Dietz syndrome (LDS) results from mutations in receptors for the cytokine transforming growth factor-ß leading to aggressive aortic pathology sometimes accompanied by specific phenotypic features including bifid uvula, hypertelorism, cleft palate, and generalized arterial tortuosity. We reviewed our adult surgical experience with LDS in order to validate current recommendations regarding management of this newly described disease. METHODS: All adult (≥ 18 years old) patients with LDS undergoing surgical treatment at a single referral institution from September 1999 to May 2013 were retrospectively reviewed. RESULTS: Eleven adult LDS patients were identified by clinical criteria and genotyping. Seven (64%) experienced acute type A dissection at some point in their lives. All eventually required aortic root replacement, and 73% required multiple vascular surgical interventions. Over a mean follow-up of 65 ± 49 months, 2.8 cardiovascular procedures per patient were performed. In patients with type A dissection, a mean of 3.4 operations were performed versus 1.8 operations for patients without dissection. Total aortic replacement was required in 5 patients (45%) and 2 (18%) required neurosurgical intervention for cerebrovascular pathology. There was 1 late death from infectious complications, and no deaths from vascular catastrophe. CONCLUSIONS: These results confirm the aggressive nature of LDS aortic pathology. However, the improved survival compared with earlier LDS reports suggest that aggressive treatment strategies may alter outcomes and improve the natural history of this syndrome.


Assuntos
Aneurisma da Aorta Torácica/cirurgia , Dissecção Aórtica/cirurgia , Procedimentos Cirúrgicos Cardíacos/métodos , Síndrome de Loeys-Dietz/cirurgia , Procedimentos Cirúrgicos Vasculares/métodos , Adulto , Dissecção Aórtica/genética , Aneurisma da Aorta Torácica/genética , Procedimentos Cirúrgicos Cardíacos/efeitos adversos , Estudos de Coortes , Feminino , Humanos , Síndrome de Loeys-Dietz/diagnóstico , Síndrome de Loeys-Dietz/mortalidade , Masculino , Pessoa de Meia-Idade , Complicações Pós-Operatórias/fisiopatologia , Complicações Pós-Operatórias/cirurgia , Prognóstico , Reoperação/métodos , Estudos Retrospectivos , Medição de Risco , Índice de Gravidade de Doença , Taxa de Sobrevida , Resultado do Tratamento , Procedimentos Cirúrgicos Vasculares/efeitos adversos , Adulto Jovem
12.
Am J Cardiol ; 115(11): 1568-73, 2015 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-25846765

RESUMO

This study sought to compare the accuracy of 2-dimensional transesophageal echocardiography (TEE) and computed tomography angiography (CTA) for noninvasive aortic annular sizing as required for transcatheter aortic valve implantation (TAVI). Direct intraoperative (OR) sizing is the gold standard for aortic annular measurement in surgical aortic valve replacement. Unlike surgical aortic valve replacement, TAVI requires noninvasive assessment of aortic annular dimensions for determining the size of prosthesis to be implanted and controversy exists regarding the best imaging technique for TAVI sizing. Preoperative CTA and OR TEE images of the aortic annulus in 227 patients who underwent proximal aortic surgery with OR annular sizing at the Duke University Medical Center were reviewed. Both imaging techniques were compared with direct OR measurements of aortic annulus diameter using metric sizers as the gold standard. CTA overestimated aortic annulus diameter in 72.2% of cases, with 46.3% >1 TAVI valve-size (>3 mm) overestimations, whereas TEE underestimated aortic annulus diameter in 51.1% of cases, with 16.7% >1 valve-size underestimations. Combining both techniques improved the estimation of aortic annular size. In conclusion, there are limitations to current imaging techniques for noninvasive determination of aortic annular dimensions compared with direct OR sizing. Undersizing by TEE and oversizing by CTA are common and may be related to differences in methods for sizing an elliptical structure. Combining measurements from both techniques would decrease the false exclusion rate for TAVI eligibility because of size mismatch.


Assuntos
Angiografia/métodos , Valva Aórtica/anatomia & histologia , Valva Aórtica/cirurgia , Ecocardiografia Transesofagiana , Tomografia Computadorizada por Raios X , Valva Aórtica/diagnóstico por imagem , Precisão da Medição Dimensional , Implante de Prótese de Valva Cardíaca , Humanos , Tamanho do Órgão , Estudos Prospectivos
13.
Thorac Surg Clin ; 24(2): 223-9, vii, 2014 May.
Artigo em Inglês | MEDLINE | ID: mdl-24780427

RESUMO

Robotic master-slave devices can assist surgeons to perform minimally invasive esophageal operations with approaches that have already been demonstrated using laparoscopy and thoracoscopy. Robotic-assisted surgery for benign esophageal disease is described for the treatment of achalasia, epiphrenic diverticula, refractory reflux, paraesophageal hernias, duplication cysts, and benign esophageal masses, such as leiomyomas. Indications and contraindications for robotic surgery in benign esophageal disease should closely approximate the indications for laparoscopic and thoracoscopic procedures. Given the early application of the technology and paucity of clinical evidence, there are currently no procedures for which robotic esophageal surgery is the clinically proven preferred approach.


Assuntos
Doenças do Esôfago/cirurgia , Robótica/métodos , Divertículo Esofágico/cirurgia , Acalasia Esofágica/cirurgia , Fundoplicatura/métodos , Refluxo Gastroesofágico/cirurgia , Hérnia Hiatal/cirurgia , História do Século XX , Humanos , Procedimentos Cirúrgicos Minimamente Invasivos/métodos , Robótica/história , Toracoscopia/métodos
14.
Ann Thorac Surg ; 98(6): 2092-7; discussion 2098, 2014 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-25282168

RESUMO

BACKGROUND: Thoracic endovascular aortic repair (TEVAR) for chronic DeBakey IIIb dissection with associated descending aneurysm remains controversial. This study examines long-term results of TEVAR for this disorder including examination of anatomic features associated with TEVAR outcomes. METHODS: Between July 2005 and January 2013, 32 patients underwent TEVAR for chronic (>30 days) DeBakey IIIb dissection involving the descending thoracic aorta at a single institution and constituted the study cohort. RESULTS: The mean interval from dissection to TEVAR was 32 ± 44 months (range, 1 to 146 months). There were no 30-day or in-hospital deaths, strokes, or paraplegia. During a 54-month median follow-up, there were no aortic-related deaths. Significant thoracic aneurysm sac regression (>1 cm) in the intervened segment was observed in 89%. Thoracic remodeling was not correlated with the number of visceral vessels arising from the true lumen or the number or size of residual distal fenestrations; failure of thoracic remodeling was associated with fenestrations distal to the endograft(s) in the descending thoracic aorta, most often stent graft-induced new entry tears. Complete resolution of the thoracic and abdominal false lumen after TEVAR was observed in 15.6% (n = 5). All patients in this group had all visceral vessels arising from the true lumen and fewer than three residual distal fenestrations. CONCLUSIONS: Thoracic endovascular aortic repair is effective for chronic DeBakey IIIb dissection with associated descending aneurysm, with excellent 30-day and long-term outcomes and significant aortic remodeling in the vast majority of patients. Thoracic remodeling does not appear dependent on distal anatomic characteristics of the true and false lumens, although care should be taken to cover all thoracic fenestrations and avoid creation of stent graft-induced new entry tears to ensure clinical success. Complete aortic remodeling was observed only in the setting of all visceral vessels off the true lumen with fewer than three residual distal fenestrations, and this would appear the ideal anatomy for TEVAR in this scenario.


Assuntos
Aneurisma da Aorta Torácica/cirurgia , Dissecção Aórtica/cirurgia , Prótese Vascular , Procedimentos Endovasculares/métodos , Stents , Dissecção Aórtica/diagnóstico , Dissecção Aórtica/mortalidade , Aneurisma da Aorta Torácica/diagnóstico , Aneurisma da Aorta Torácica/mortalidade , Doença Crônica , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , North Carolina/epidemiologia , Estudos Retrospectivos , Índice de Gravidade de Doença , Taxa de Sobrevida/tendências , Fatores de Tempo , Tomografia Computadorizada por Raios X , Resultado do Tratamento
15.
J Thorac Cardiovasc Surg ; 147(1): 186-191.e1, 2014 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-24183336

RESUMO

OBJECTIVES: Although frailty has recently been examined in various populations as a predictor of morbidity and mortality, its effect on thoracic aortic surgery outcomes has not been studied. The objective of the present study was to evaluate the role of frailty in predicting postoperative morbidity and mortality in patients undergoing proximal aortic replacement surgery. METHODS: A retrospective analysis of a prospectively maintained database was performed for all patients undergoing elective and nonelective proximal aortic operations (root, ascending aorta, and/or arch) at a single-referral institution from June 2005 to December 2012. A total of 581 patients underwent proximal aortic surgery, of whom 574 (98.8%) were included in the present analysis; 7 were excluded because of incomplete data. Frailty was evaluated using an index consisting of age >70 years, body mass index <18.5 kg/m(2), anemia, history of stroke, hypoalbuminemia, and total psoas volume in the bottom quartile of the population. One point was given for each criterion met to determine a frailty score of 0 to 6. Frailty was defined as a score of ≥2. Risk models for length of stay >14 days, discharge to other than home, 30-day composite major morbidity, 30-day composite major morbidity/mortality, and 30-day and 1-year mortality were calculated using multivariate regression modeling. RESULTS: Of the 574 patients, 148 (25.7%) were defined as frail (frailty score ≥2). The unadjusted 30-day/in-hospital and long-term outcomes were significantly worse for the frail versus nonfrail patients in all but 1 of the outcomes analyzed; no difference was found in the 30-day readmission rates between the 2 groups. In the multivariate model, a frailty score of ≥2 was associated with discharge to other than home and 30-day and 1-year mortality. CONCLUSIONS: Frailty, as defined using a 6-component frailty index, can serve as an independent predictor of discharge disposition and early and late mortality risk in patients undergoing proximal aortic surgery. These frailty markers, all of which are easily assessed preoperatively, could provide valuable information for patient counseling and risk stratification before proximal aortic replacement.


Assuntos
Aorta Torácica/cirurgia , Idoso Fragilizado , Avaliação Geriátrica , Complicações Pós-Operatórias/etiologia , Procedimentos Cirúrgicos Vasculares/efeitos adversos , Adulto , Fatores Etários , Idoso , Implante de Prótese Vascular/efeitos adversos , Feminino , Humanos , Estimativa de Kaplan-Meier , Modelos Logísticos , Masculino , Pessoa de Meia-Idade , Análise Multivariada , North Carolina , Alta do Paciente , Readmissão do Paciente , Complicações Pós-Operatórias/mortalidade , Complicações Pós-Operatórias/terapia , Estudos Retrospectivos , Medição de Risco , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento
16.
J Thorac Cardiovasc Surg ; 147(4): 1164-8, 2014 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-24507984

RESUMO

OBJECTIVES: We sought to determine the prognostic significance of extralobar nodal metastases versus intralobar nodal metastases in patients with lung cancer and pathologic stage N1 disease. METHODS: A retrospective review of a prospectively maintained lung resection database identified 230 patients with pathologic stage II, N1 non-small cell lung cancer from 1997 to 2011. The surgical pathology reports were reviewed to identify the involved N1 stations. The outcome variables included recurrence and death. Univariate and multivariate analyses were performed using the R statistical software package. RESULTS: A total of 122 patients had extralobar nodal metastases (level 10 or 11); 108 patients were identified with intralobar nodal disease (levels 12-14). The median follow-up was 111 months. The baseline characteristics were similar in both groups. No significant differences were noted in the surgical approach, anatomic resections performed, or adjuvant therapy rates between the 2 groups. Overall, 80 patients developed recurrence during follow-up: 33 (30%) of 108 in the intralobar and 47 (38%) of 122 in the extralobar cohort. The median overall survival was 46.9 months for the intralobar cohort and 24.4 months for the extralobar cohort (P < .001). In a multivariate Cox proportional hazard model that included the presence of extralobar nodal disease, age, tumor size, tumor histologic type, and number of positive lymph nodes, extralobar nodal disease independently predicted both recurrence-free and overall survival (hazard ratio, 1.96; 95% confidence interval, 1.36-2.81; P = .001). CONCLUSIONS: In patients who underwent surgical resection for stage II non-small cell lung cancer, the presence of extralobar nodal metastases at level 10 or 11 predicted significantly poorer outcomes than did nodal metastases at stations 12 to 14. This finding has prognostic importance and implications for adjuvant therapy and surveillance strategies for patients within the heterogeneous stage II (N1) category.


Assuntos
Carcinoma Pulmonar de Células não Pequenas/secundário , Carcinoma Pulmonar de Células não Pequenas/cirurgia , Neoplasias Pulmonares/patologia , Neoplasias Pulmonares/cirurgia , Pneumonectomia , Idoso , Carcinoma Pulmonar de Células não Pequenas/mortalidade , Terapia Combinada , Humanos , Neoplasias Pulmonares/mortalidade , Pessoa de Meia-Idade , Estadiamento de Neoplasias , Prognóstico , Estudos Retrospectivos , Taxa de Sobrevida
17.
J Am Coll Cardiol ; 63(17): 1796-803, 2014 May 06.
Artigo em Inglês | MEDLINE | ID: mdl-24412454

RESUMO

OBJECTIVES: The purpose of this study was to compare the results of acute type A aortic dissection (ATAAD) repair before and after implementation of a multidisciplinary thoracic aortic surgery program (TASP) at our institution, with dedicated high-volume thoracic aortic surgeons, a multidisciplinary approach to thoracic aortic disease management, and a standardized protocol for ATAAD repair. BACKGROUND: Outcomes of ATAAD repair may be improved when operations are performed at specialized high-volume thoracic aortic surgical centers. METHODS: Between 1999 and 2011, 128 patients underwent ATAAD repair at our institution. Records of patients who underwent ATAAD repair 6 years before (n = 56) and 6 years after (n = 72) implementation of the TASP were retrospectively compared. Expected operative mortality rates were calculated using the International Registry of Acute Aortic Dissection pre-operative prediction model. RESULTS: Baseline risk profiles and expected operative mortality rates were comparable between patients who underwent surgery before and after implementation of the TASP. Operative mortality before TASP implementation was 33.9% and was statistically equivalent to the expected operative mortality rate of 26.0% (observed-to-expected mortality ratio 1.30; p = 0.54). Operative mortality after TASP implementation fell to 2.8% and was statistically improved compared with the expected operative mortality rate of 18.2% (observed-to-expected mortality ratio 0.15; p = 0.005). Differences in survival persisted over long-term follow-up, with 5-year survival rates of 85% observed for TASP patients compared with 55% for pre-TASP patients (p = 0.002). CONCLUSIONS: ATAAD repair can be performed with results approximating those of elective proximal aortic surgery when operations are performed by a high-volume multidisciplinary thoracic aortic surgery team. Efforts to standardize or centralize care of patients undergoing ATAAD are warranted.


Assuntos
Aneurisma da Aorta Torácica/cirurgia , Dissecção Aórtica/cirurgia , Procedimentos Cirúrgicos Eletivos/métodos , Comunicação Interdisciplinar , Sistema de Registros , Procedimentos Cirúrgicos Vasculares/métodos , Doença Aguda , Adulto , Idoso , Idoso de 80 Anos ou mais , Dissecção Aórtica/diagnóstico , Dissecção Aórtica/mortalidade , Aneurisma da Aorta Torácica/diagnóstico , Aneurisma da Aorta Torácica/mortalidade , Feminino , Seguimentos , Mortalidade Hospitalar/tendências , Humanos , Masculino , Pessoa de Meia-Idade , Período Pós-Operatório , Período Pré-Operatório , Estudos Retrospectivos , Taxa de Sobrevida/tendências , Fatores de Tempo , Resultado do Tratamento , Estados Unidos/epidemiologia , Adulto Jovem
18.
Ann Thorac Surg ; 98(6): 2061-7, 2014 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-25301369

RESUMO

BACKGROUND: A growing literature describes aneurysmal deterioration after implantation of the stentless porcine aortic Medtronic Freestyle bioprosthesis (MFB; Medtronic Inc, Minneapolis, MN), with some suggesting inadequate tissue fixation with immune response as a cause. However, disjointed reports make the significance of these findings difficult to interpret. We address this concern by aggregating available data. METHODS: We reviewed institutional data, the Food and Drug Administration's Manufacturer and User Facility Device Experience registry, and the medical literature for mention of aneurysm or pseudoaneurysm after MFB. Case details were aggregated, and the rate of aneurysmal deterioration was estimated. Immunohistopathologic examination of institutional explanted specimens was performed to elucidate a cause. RESULTS: We found 42 cases of aneurysmal deterioration with adequate detail for analysis; all occurred with full root replacement and valve sizes ranging from 23 to 29 mm. The rate of aneurysmal deterioration considering all data sources was 1.1% (9 of 851; 95% confidence interval, 0.5% to 2.0%) vs 4.7% (4 of 86; 95% confidence interval, 1.3% to 11.5%) at our institution, where yearly surveillance imaging is performed. Rate of aneurysmal deterioration appeared constant until 5 years after the operation; however, events are reported out to 10 years. Consistent with previous reports, histopathology demonstrated an immune cell infiltrate in areas of MFB wall breakdown. CONCLUSIONS: Aneurysmal deterioration is an increasingly described complication of MFB implantation as a full root, with an incidence as high as 4.7%. Given the observed immune reaction and lack of occurrence in smaller (19-mm and 21-mm) valve sizes, inadequate pressure fixation of larger valves is a potential etiology. Patients with MFB require annual surveillance imaging, and consideration of this complication should factor into preoperative decision making because treatment mandates redo root replacement, which may not be feasible in high-risk patients.


Assuntos
Falso Aneurisma/etiologia , Aneurisma da Aorta Torácica/etiologia , Estenose da Valva Aórtica/cirurgia , Bioprótese/efeitos adversos , Próteses Valvulares Cardíacas/efeitos adversos , Adulto , Falso Aneurisma/diagnóstico , Angiografia , Animais , Aneurisma da Aorta Torácica/diagnóstico , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico , Feminino , Seguimentos , Humanos , Imageamento Tridimensional , Imagem Cinética por Ressonância Magnética , Masculino , Complicações Pós-Operatórias , Estudos Prospectivos , Desenho de Prótese , Falha de Prótese , Suínos , Tomografia Computadorizada por Raios X , Adulto Jovem
19.
J Thorac Cardiovasc Surg ; 148(5): 2082-6, 2014 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-24725770

RESUMO

OBJECTIVE: Nonelective case status is the strongest predictor of mortality for thoracic aortic operations. We hypothesized that underinsured patients were more likely to require nonelective thoracic aortic surgery because of reduced access to preventative cardiovascular care and elective surgical services. METHODS: Between June 2005 and August 2011, 826 patients were admitted to a single aortic referral center and underwent 1 or more thoracic aortic operations. Patients with private insurance or Medicare (insured group, n=736; 89%) were compared with those with Medicaid or no insurance (underinsured group, n=90; 11%). RESULTS: The proportion of patients requiring nonelective surgery was higher for underinsured than insured patients (56% vs 26%, P<.0001). Multivariable analysis revealed underinsurance to be the strongest independent predictor of nonelective case status (odds ratio [OR], 2.67; P<.0001). Preoperative use of lipid-lowering medications (OR, 0.63; P<.009) or a history of aortic surgery (OR, 0.48; P<.001) was associated with a decreased risk of nonelective operation. However, after adjustment for differences in preoperative characteristics and case status, underinsurance did not confer an increased risk of procedural morbidity or mortality (adjusted OR, 0.94; P=.83) or late death (adjusted hazard ratio, 0.83, P=.58) when compared with insured patients. CONCLUSIONS: Underinsured patients were at the greatest risk of requiring nonelective thoracic aortic operation, possibly because of decreased use of lipid-lowering therapies and aortic surveillance. These data imply that greater access to preventative cardiovascular care may reduce the need for nonelective thoracic aortic surgery and lead to improved survival from thoracic aortic disease.


Assuntos
Aorta Torácica/cirurgia , Doenças da Aorta/cirurgia , Cobertura do Seguro , Seguro Saúde , Pessoas sem Cobertura de Seguro de Saúde , Procedimentos Cirúrgicos Vasculares , Adulto , Idoso , Doenças da Aorta/diagnóstico , Doenças da Aorta/economia , Doenças da Aorta/mortalidade , Procedimentos Cirúrgicos Eletivos , Emergências , Feminino , Humanos , Hipolipemiantes/uso terapêutico , Cobertura do Seguro/economia , Seguro Saúde/economia , Masculino , Medicaid , Medicare , Pessoa de Meia-Idade , Análise Multivariada , Razão de Chances , Setor Privado , Modelos de Riscos Proporcionais , Estudos Retrospectivos , Fatores de Risco , Resultado do Tratamento , Estados Unidos , Procedimentos Cirúrgicos Vasculares/efeitos adversos , Procedimentos Cirúrgicos Vasculares/economia , Procedimentos Cirúrgicos Vasculares/mortalidade
20.
J Thorac Cardiovasc Surg ; 148(6): 2896-902, 2014 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-24908350

RESUMO

OBJECTIVE: The choice of cerebral perfusion strategy for aortic arch surgery has been debated, and the superiority of antegrade (ACP) or retrograde (RCP) cerebral perfusion has not been shown. We examined the early and late outcomes for ACP versus RCP in proximal (hemi-) arch replacement using deep hypothermic circulatory arrest (DHCA). METHODS: A retrospective analysis of a prospectively maintained database was performed for all patients undergoing elective and nonelective hemiarch replacement at a single referral institution from June 2005 to February 2013. Total arch cases were excluded to limit the analysis to shorter DHCA times and a more uniform patient population for whom clinical equipoise regarding ACP versus RCP exists. A total of 440 procedures were identified, with 360 (82%) using ACP and 80 (18%) using RCP. The endpoints included 30-day/in-hospital and late outcomes. A propensity score with 1:1 matching of 40 pre- and intraoperative variables was used to adjust for differences between the 2 groups. RESULTS: All 80 RCP patients were propensity matched to a cohort of 80 similar ACP patients. The pre- and intraoperative characteristics were not significantly different between the 2 groups after matching. No differences were found in 30-day/in-hospital mortality or morbidity outcomes. The only significant difference between the 2 groups was a shorter mean operative time in the RCP cohort (P = .01). No significant differences were noted in late survival (P = .90). CONCLUSIONS: In proximal arch operations using DHCA, equivalent early and late outcomes can be achieved with RCP and ACP, although the mean operative time is significantly less with RCP, likely owing to avoidance of axillary cannulation. Questions remain regarding comparative outcomes with straight DHCA and lesser degrees of hypothermia.


Assuntos
Aorta Torácica/cirurgia , Aneurisma da Aorta Torácica/cirurgia , Dissecção Aórtica/cirurgia , Ruptura Aórtica/cirurgia , Implante de Prótese Vascular , Circulação Cerebrovascular , Parada Circulatória Induzida por Hipotermia Profunda , Perfusão/métodos , Adulto , Idoso , Dissecção Aórtica/diagnóstico , Dissecção Aórtica/mortalidade , Dissecção Aórtica/fisiopatologia , Aorta Torácica/fisiopatologia , Aneurisma da Aorta Torácica/diagnóstico , Aneurisma da Aorta Torácica/mortalidade , Aneurisma da Aorta Torácica/fisiopatologia , Ruptura Aórtica/diagnóstico , Ruptura Aórtica/mortalidade , Ruptura Aórtica/fisiopatologia , Implante de Prótese Vascular/efeitos adversos , Implante de Prótese Vascular/mortalidade , Distribuição de Qui-Quadrado , Parada Circulatória Induzida por Hipotermia Profunda/efeitos adversos , Parada Circulatória Induzida por Hipotermia Profunda/mortalidade , Feminino , Mortalidade Hospitalar , Humanos , Estimativa de Kaplan-Meier , Masculino , Pessoa de Meia-Idade , Perfusão/efeitos adversos , Perfusão/mortalidade , Pontuação de Propensão , Sistema de Registros , Estudos Retrospectivos , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA