Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros

Base de dados
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Knee Surg Sports Traumatol Arthrosc ; 32(5): 1308-1316, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38504506

RESUMO

PURPOSE: The aim of this study was to analyse the functional outcome and the conversion rate to total knee arthroplasty (TKA) after surgically treated tibial plateau fractures (TPF). METHODS: All patients undergoing surgical treatment of TPF at a single institution between January 2003 and December 2019 were retrospectively reviewed. The Knee injury and Osteoarthritis Outcome Score (KOOS) and Tegner activity scale (TAS) were collected. The conversion rate to TKA was examined 2, 5, 7 and 10 years after surgical treatment of TPF. RESULTS: Ninety-four patients, with a mean follow-up of 110.6 months (±60.0), were included in the functional outcome assessment. Mean KOOS scores were 75.4 for symptoms, 80.6 for pain, 84.3 for activities of daily living (ADL), 59.5 for sports and 61.3 for QOL. All subscales were significantly lower on the injured side compared with the contralateral leg. Lower KOOS was observed in patients with hardware removal and Schatzker type 5 and 6 injuries. Median TAS was postinjury (4) significantly lower than preinjury (5) (p < 0.001). The conversion rate to TKA was 6.3%, 10.9%, 11.7% and 12.2% after 2,5,7 and 10 years of follow-up, respectively. Patients undergoing TKA were older than patients with no conversion to TKA (2 years follow-up 53.8 vs. 64.5 years, p = 0.026). CONCLUSION: TPFs decrease the function of the knee when compared with the contralateral side and to the preoperative condition. Bicondylar fractures are associated with worse functional outcomes. A conversion rate to TKA of 12.2% was found at 10 years follow-up. LEVEL OF EVIDENCE: Level III.


Assuntos
Artroplastia do Joelho , Fraturas da Tíbia , Humanos , Feminino , Masculino , Fraturas da Tíbia/cirurgia , Pessoa de Meia-Idade , Estudos Retrospectivos , Idoso , Atividades Cotidianas , Adulto , Resultado do Tratamento , Recuperação de Função Fisiológica , Fraturas do Planalto Tibial
2.
J Pers Med ; 13(2)2023 Feb 17.
Artigo em Inglês | MEDLINE | ID: mdl-36836591

RESUMO

(1) Background: Magnesium-based implants use has become a research focus in recent years. Radiolucent areas around inserted screws are still worrisome. The objective of this study was to investigate the first 18 patients treated using MAGNEZIX® CS screws. (2) Methods: This retrospective case series included all 18 consecutive patients treated using MAGNEZIX® CS screws at our Level-1 trauma center. Radiographs were taken at 3-, 6- and 9-month follow-ups. Osteolysis, radiolucency and material failure were assessed, as were infection and revision surgery. (3) Results: Most patients (61.1%) had surgery in the shoulder region. Radiolucency regressed from 55.6% at 3-month follow-ups to 11.1% at 9-month follow-ups. Material failure occurred in four patients (22.22%) and infection occurred in two patients, yielding a 33.33% complication rate. (4) Conclusion: MAGNEZIX® CS screws demonstrated a high percentage of radiolucency that regressed and seems to be clinically irrelevant. The material failure rate and infection rate require further research.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA