Pacing Clin Electrophysiol ; 37(2): 231-6, 2014 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-23998792

RESUMO

BACKGROUND: There are only limited prospective data on the clinical relevance of current of injury (COI) as a predictor of the midterm performance of active-fixation leads. This study sought to investigate whether it is possible to predict the midterm performance of active-fixation leads using COI recorded at the time of implantation. METHODS AND RESULTS: One hundred fifty patients (78 men; mean age, 63 ± 19 years) who received active-fixation pacing (n = 201) and defibrillator (n = 51) leads were studied. COI was measured from the intracardiac bipolar electrogram recorded at the time of lead implantation. The study outcome was good lead performance at 6 months, defined as P wave ≥ 1.5 mV, threshold <1.5 V for atrial lead, R-wave ≥ 5 mV, and threshold <1 V for ventricular lead. A total of 102 active-fixation atrial and 150 ventricular leads were implanted. During a 6-month follow-up, invasive intervention was required for seven atrial and seven ventricular leads. In multivariate analysis, COI was the only independent predictor of good outcome for the active-fixation atrial (odds ratio [OR]: 5.67, 95% confidence interval [CI]: 2.18-14.76, P = 0.001) and ventricular leads (OR: 3.99, 95% CI: 1.08-21.26, P = 0.002). Receiver-operating characteristic analysis identified ST-segment elevation ≥2.0 mV for the atrial leads (sensitivity, 75%; specificity, 89%) and ≥10.0 mV for the ventricular leads (sensitivity, 70%; specificity, 87%) as optimal cutoffs for good midterm performance. CONCLUSIONS: Midterm performance of active-fixation leads is predictable using COI recorded at the time of lead implantation. A ST-segment elevation ≥2.0 mV in the atrial leads and ≥10.0 mV in the ventricular leads are recommended to improve the lead performance at 6 months.


Assuntos
Fibrilação Atrial/terapia , Eletrodos Implantados , Marca-Passo Artificial , Disfunção Ventricular Esquerda/terapia , Fibrilação Atrial/complicações , Fibrilação Atrial/diagnóstico , Desenho de Equipamento , Análise de Falha de Equipamento , Feminino , Humanos , Estudos Longitudinais , Masculino , Pessoa de Meia-Idade , Resultado do Tratamento , Disfunção Ventricular Esquerda/diagnóstico , Disfunção Ventricular Esquerda/etiologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA