Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Phys Rev Lett ; 123(3): 031101, 2019 Jul 19.
Artigo em Inglês | MEDLINE | ID: mdl-31386438

RESUMO

The Laser Ranging Interferometer (LRI) instrument on the Gravity Recovery and Climate Experiment (GRACE) Follow-On mission has provided the first laser interferometric range measurements between remote spacecraft, separated by approximately 220 km. Autonomous controls that lock the laser frequency to a cavity reference and establish the 5 degrees of freedom two-way laser link between remote spacecraft succeeded on the first attempt. Active beam pointing based on differential wave front sensing compensates spacecraft attitude fluctuations. The LRI has operated continuously without breaks in phase tracking for more than 50 days, and has shown biased range measurements similar to the primary ranging instrument based on microwaves, but with much less noise at a level of 1 nm/sqrt[Hz] at Fourier frequencies above 100 mHz.

2.
Rapid Commun Mass Spectrom ; 28(13): 1413-25, 2014 Jul 15.
Artigo em Inglês | MEDLINE | ID: mdl-24861590

RESUMO

RATIONALE: High-precision stable isotope measurements in gas-source isotope ratio mass spectrometry are generally carried out by repeated comparison of the composition of an unknown sample with that of a working gas (WG) through a dual-inlet (DI). Due to the established DI protocols, however, most of the sample gas is wasted rather than measured, which is a major problem when sample size is limited. Here we propose a new methodology allowing the measurement of a much larger portion of the available sample. METHODS: We tested a new measurement protocol, the long-integration dual-inlet (LIDI) method, which consists of a single measurement of the sample for 200 to 600 seconds followed by a single measurement of the WG. The isotope ratios of the sample are calculated by comparison of the beam ratios of the WG and sample at equivalent intensities of the major ion beam. RESULTS: Three isotopically very different CO2 samples were analyzed. The LIDI measurements of large samples (50 to 100 µmol of CO2) measured at quasi-constant beam sizes, and of small samples (1.5 to 2 µmol of CO2) measured in micro-volume mode, generated results that are indistinguishable from the standard DI measurements for carbon, oxygen and clumped isotope compositions. The external precision of Δ47 using the LIDI protocol (~±0.007‰) is similar to that of the state of the art DI measurements. CONCLUSIONS: For traditional and clumped isotope measurements of CO2, the LIDI protocol allows the measurement of a much larger portion of the sample gas rather than only ~20% of it. In addition, the sample can be measured at higher signal intensity and for longer time, allowing the measurement of smaller samples while preserving precision. We suggest that other gases commonly used for stable isotope measurements with gas-source mass spectrometry would also benefit from this new protocol.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA