Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 61
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Catheter Cardiovasc Interv ; 101(3): 668-675, 2023 02.
Artigo em Inglês | MEDLINE | ID: mdl-36701398

RESUMO

OBJECTIVES: We review our experience with 13 periprocedural aortic dissection (AD) cases caused by transcatheter aortic valve replacement (TAVR). BACKGROUND: AD is a potentially lethal complication of TAVR; however, only sporadic case reports have been published to date. METHODS: Among 1335 consecutive patients who underwent TAVR in 2013-2021, we retrospectively extracted 13 patients (1.0%) with TAVR-related AD (Stanford type A in 6 [46%], type B in 7 [54%]). AD was defined as a new-onset dissected layer of the aortic wall and diagnosed by aortography, computed tomography, or transesophageal echocardiography. RESULTS: Five of the six type A AD cases (83%) were detected during TAVR versus only one of the seven type B AD cases (14%). Four of the seven type B AD cases (57%) were asymptomatic and incidentally detected on computed tomography. The presumed causes of AD were injury by the delivery sheath (39%), delivery catheter (23%), valve implantation (15%), stent edge (15%), and pre-dilation balloon (8%). Complicated AD occurred in only one patient (8%). Considering the patient's age and prohibitive surgical risk, all patients were treated conservatively and free of any aortic-related deaths or interventions during a follow-up of 1087 days. CONCLUSIONS: TAVR-related AD is a rare but life-threatening condition that may be underdiagnosed. Its optimal therapy remains unclear, and conservative management might be an option for selected patients. Further studies are needed to elucidate the incidence, risk factors, effective screening, optimal therapy, and outcomes of TAVR-related AD.


Assuntos
Dissecção Aórtica , Estenose da Valva Aórtica , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Humanos , Dissecção Aórtica/diagnóstico por imagem , Dissecção Aórtica/etiologia , Dissecção Aórtica/cirurgia , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Estudos Retrospectivos , Fatores de Risco , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/métodos , Resultado do Tratamento
2.
Cereb Cortex ; 32(19): 4304-4316, 2022 09 19.
Artigo em Inglês | MEDLINE | ID: mdl-35040933

RESUMO

This magnetic resonance imaging study is designed to obtain relevant implications for criminal justice and explores the effective connectivity underlying expertise. Laypersons and experts considered sentences for remorseful and remorseless defendants, respectively, with and without mitigation, in hypothetical murder cases. Two groups revealed no differential activation. However, dynamic causal modeling analysis found distinct patterns of connectivity associated with subjects' expertise and mitigating factors. In sentencing for remorseful defendants, laypersons showed increased strength in all bidirectional connections among activated regions of Brodmann area (BA) 32, BA23, the right posterior insula, and the precuneus. In contrast, legal experts sentenced based on mitigation reasoning, showed increased strength only in the bidirectional connection between the insula and the precuneus. When sentencing for remorseless ones without mitigation, both laypersons and experts increased the connection strength, but with reverse directionality, between regions; legal experts strengthened connectivity from BA10 to other regions, that is, the right anterior insula and BA23, but the directionality was reversed in laypersons. In addition, the strength of connection to BA32 and BA10 was correlated with changes in punishments by mitigating factors. This is a crucial result that establishes the validity of the connectivity estimates, which were uninformed by the independent (behavioral) differences in the severity of punishment.


Assuntos
Criminosos , Giro do Cíngulo , Humanos , Imageamento por Ressonância Magnética , Lobo Parietal , Punição
3.
J Thromb Thrombolysis ; 56(1): 45-54, 2023 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-37061662

RESUMO

Data from several recent studies have demonstrated the safety and efficacy of transcatheter aortic valve implantation (TAVI) for severe aortic stenosis (AS) even in nonagenarians. However, the impact of periprocedural bleeding following TAVI on their outcome remains unclear. In the aLliAnce for exPloring cLinical prospects of AortiC valvE disease (LAPLACE) registry, we compared outcomes between the bleeding and no-bleeding groups among 1953 patients < 90 years old (mean age, 83.0 ± 4.6 years old) and 316 nonagenarians (mean age, 91.7 ± 1.9 years old) who underwent TAVI with a median follow-up period of 628 days. The group with any periprocedural bleeding showed a higher 30-day mortality than the no-bleeding group in patients < 90 years old (3.3% vs. 0.5%, p = 0.001) and nonagenarians (7.9% vs. 0.7%, p = 0.001). In patients < 90 years old, severe periprocedural bleeding (n = 85) was associated with a higher mid-term all-cause mortality rate than no severe bleeding (n = 1,868), even after adjusting for covariates (hazard ratio [HR], 1.994; 95% confidence interval [CI] 1.287-2.937; p = 0.002). On the other hand, in nonagenarians, any periprocedural bleeding (n = 38) was associated with a higher mid-term cardiovascular (CV) mortality rate (21.1% vs. 4.3%, log-rank p = 0.014) than no bleeding (n = 278), even after adjusting for covariates (HR, 3.104; 95% CI 1.140-8.449; p = 0.027). In conclusion, any periprocedural bleeding after TAVI was associated with mid-term CV mortality in nonagenarians, whereas severe bleeding was associated with mid-term all-cause mortality in patients < 90 years old.


Assuntos
Estenose da Valva Aórtica , Substituição da Valva Aórtica Transcateter , Idoso de 80 Anos ou mais , Humanos , Idoso , Substituição da Valva Aórtica Transcateter/efeitos adversos , Nonagenários , Estenose da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/complicações , Fatores de Risco , Valva Aórtica/cirurgia , Hemorragia/etiologia , Sistema de Registros , Resultado do Tratamento
4.
J Intensive Care Med ; 35(2): 154-160, 2020 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-28931366

RESUMO

PURPOSE: Postoperative intensive care unit (ICU) stay after cardiac surgeries has been extensively studied, but little attention has been given to ICU stay following transcatheter aortic valve replacement (TAVR). This study examined ICU stay after TAVR. METHODS: Two hundred and forty-five patients who underwent TAVR between April 2010 and October 2016 were studied retrospectively. We investigated the status of ICU stay, the predictors of prolonged ICU stay (PICUS), and its impact on short- and long-term outcomes. Prolonged ICU stay was defined as post-TAVR ICU stay longer than 2 days (day of TAVR + 1 day). RESULTS: Length of ICU stay was 2.6 ± 4.9 days, and PICUS was identified in 14.7% of the patients. The predominant reason for PICUS was congestive heart failure or circulatory failure (41.7%). Pulmonary dysfunction and nontransfemoral approach were independent predictors of PICUS (pulmonary dysfunction: odds ratio = 2.64, 95% confidence interval [CI]: 1.05-7.35; nontransfemoral approach: odds ratio = 2.81, 95% CI: 1.15-6.89). Prolonged ICU stay was associated with higher rate of 30-day combined end point (PICUS vs non-PICUS: 44.4% vs 3.3%, P < .0001), longer postoperative hospital stay (49.9 ± 141.9 days vs 12.0 ± 6.0 days, P < .0001), and lower rate of discharge home (77.8% vs 95.2%, P = .0002). Patients with PICUS had worse long-term survival (P < .0001), and PICUS was a predictor of mortality (hazard ratio: 4.21, 95% CI: 2.09-8.22). CONCLUSION: Prolonged ICU stay following TAVR was found in 14.7%, and pulmonary dysfunction and nontransfemoral approach were associated with PICUS. Short- and long-term prognoses were worse in patients with PICUS than those without.


Assuntos
Unidades de Terapia Intensiva/estatística & dados numéricos , Tempo de Internação/estatística & dados numéricos , Pneumopatias/mortalidade , Complicações Pós-Operatórias/mortalidade , Substituição da Valva Aórtica Transcateter/efeitos adversos , Idoso , Idoso de 80 Anos ou mais , Feminino , Mortalidade Hospitalar , Humanos , Pneumopatias/etiologia , Masculino , Razão de Chances , Complicações Pós-Operatórias/etiologia , Período Pós-Operatório , Modelos de Riscos Proporcionais , Estudos Retrospectivos , Fatores de Tempo
5.
Heart Vessels ; 35(9): 1281-1289, 2020 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-32253528

RESUMO

Futility denotes failure to achieve the projected outcome. We investigated the prevalence, predictors, and clinical risk model of transcatheter aortic valve implantation (TAVI)-related futility. We included 464 consecutive patients undergoing TAVI from 2010 to 2017. Futility was defined as death and/or hospitalization for heart failure (HFH) within 1 year after TAVI. Of 464 patients (mean age: 84.4 years), 69% were females (EuroSCOREII: 6.3%; Society of Thoracic Surgeons [STS] score: 6.9%). Forty-six patients (9.9%) experienced TAVI-related futility, and 36 of 46 patients (69.6%) died within 1 year due to cardiac (37.5%) and non-cardiac (62.5%) causes. Previous HFH (hazard ratio [HR], 2.20; 95% confidence interval [CI]: 1.13-4.35, p = 0.020), chronic obstructive pulmonary disease (COPD) (HR, 3.39; 95% CI: 1.12-8.42, p = 0.033), and moderate/severe mitral or tricuspid regurgitation (HR, 2.98; 95% CI: 1.32-6.27, p = 0.010) were independent predictors of futility. With 1 point assigned to each predictor (total 0 point, futility low-risk; total 1 point, futility intermediate-risk; total 2-3 points, futility high-risk), the futility risk model clearly stratified individual futility risk into three groups (the freedom from futility at 1 year: 96.2%, 82.1%, and 67.9% each). Our futility risk model presented better discrimination than EuroSCOREII, and STS score (c-statistic: 0.73 vs. 0.68 vs. 0.67). Medical futility was recognized in 9.9% of patients undergoing TAVI. Previous HFH, COPD, and concomitant atrioventricular regurgitation were associated with futility. The risk model derived from three predictors showed good performance in predicting futility risk.


Assuntos
Estenose da Valva Aórtica/cirurgia , Valva Aórtica/cirurgia , Regras de Decisão Clínica , Insuficiência Cardíaca/epidemiologia , Futilidade Médica , Substituição da Valva Aórtica Transcateter/efeitos adversos , Idoso , Idoso de 80 Anos ou mais , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/fisiopatologia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/mortalidade , Estenose da Valva Aórtica/fisiopatologia , Bases de Dados Factuais , Feminino , Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/mortalidade , Insuficiência Cardíaca/fisiopatologia , Humanos , Japão/epidemiologia , Masculino , Readmissão do Paciente , Valor Preditivo dos Testes , Prevalência , Estudos Retrospectivos , Medição de Risco , Fatores de Risco , Fatores de Tempo , Substituição da Valva Aórtica Transcateter/mortalidade , Resultado do Tratamento
6.
Circ J ; 83(8): 1755-1761, 2019 07 25.
Artigo em Inglês | MEDLINE | ID: mdl-31189752

RESUMO

BACKGROUND: The purpose of this study was to investigate if the transcatheter aortic valve replacement (TAVR) risk score can independently predict outcomes following TAVR, and to evaluate its predictive performance.Methods and Results:This retrospective multicenter study comprised 682 patients with severe aortic stenosis who underwent TAVR. The primary endpoint was all-cause death following TAVR. The clinical model was established using variables identified as independent predictors in the multivariate analysis. Incremental values were assessed after adding atrial fibrillation, body mass index (BMI), and serum albumin to the TAVR risk score in receiver-operating characteristic analysis. The median TAVR risk score was 2.1% with a mean follow-up of 505 days. On Kaplan-Meier analysis, a TAVR risk score >4% had lowest survival rate, whereas TAVR risk score ≤2% had the highest survival rate at 3 years (log-rank P<0.001). The multivariate Cox regression analysis found the TAVR risk score was independently associated with all-cause death, and demonstrated moderate predictive performance for predicting all-cause death at 3 years. However, if each independent predictor is added to the model, it significantly increased discriminatory performance, particularly with BMI and serum albumin level. CONCLUSIONS: We demonstrated that the TAVR risk score could independently predict mid-term death following TAVR, and had greater predictive performance for predicting all-cause death at 3 years with BMI and serum albumin level.


Assuntos
Estenose da Valva Aórtica/cirurgia , Valva Aórtica/cirurgia , Técnicas de Apoio para a Decisão , Substituição da Valva Aórtica Transcateter , Idoso , Idoso de 80 Anos ou mais , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/fisiopatologia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/mortalidade , Estenose da Valva Aórtica/fisiopatologia , Biomarcadores/sangue , Índice de Massa Corporal , Causas de Morte , Feminino , Humanos , Japão , Masculino , Complicações Pós-Operatórias/mortalidade , Valor Preditivo dos Testes , Recuperação de Função Fisiológica , Estudos Retrospectivos , Medição de Risco , Fatores de Risco , Albumina Sérica Humana/metabolismo , Índice de Gravidade de Doença , Fatores de Tempo , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/mortalidade , Resultado do Tratamento
7.
Int Heart J ; 60(2): 352-358, 2019 Mar 20.
Artigo em Inglês | MEDLINE | ID: mdl-30745544

RESUMO

Cirrhosis is a significant adverse factor of cardiac surgeries. Transcatheter aortic valve implantation (TAVI) has evolved as a less invasive therapy for aortic stenosis, whereas detailed case analysis of TAVI in cirrhotic patients is limited.Among 444 consecutive patients who underwent TAVI in the Sakakibara Heart Institute between October 2013 and January 2018, we retrospectively reviewed 11 patients (2.5%) with cirrhosis. All outcomes were defined according to the Valve Academic Research Consortium-2 criteria.The median age of the patients was 82 years, and eight (73%) were female. Seven patients (64%) were Child-Turcotte-Pugh class A, and four patients (36%) were class B. The Model for End-Stage Liver Disease score was 10 (7.0-13). TAVI was performed using Edwards SAPIEN XT/SAPIEN3 in nine patients (82%), and Medtronic CoreValve/Evolut R in two patients (18%), via transfemoral (n = 8, 73%) or transapical (n = 3, 27%) approach. The device success rate was 100% and no extracorporeal circulation had been inducted. No death, stroke, life-threatening bleeding, and acute kidney injury stage 2 or 3 occurred within 30 days, but three major bleeding events (27%) were documented (two access-site bleeding in transapical approach, and one pulmonary hemorrhage caused by transient mitral regurgitation). During a median follow-up of 493 days, four deaths had occurred, and the mid-term survival rate was 81% and 65% at one and two years each.TAVI is a promising therapeutic option for patients with cirrhosis. Further study should be needed regarding optimal patient selection and procedures in patients with cirrhosis.


Assuntos
Estenose da Valva Aórtica , Cirrose Hepática , Complicações Pós-Operatórias , Substituição da Valva Aórtica Transcateter , Idoso , Idoso de 80 Anos ou mais , Estenose da Valva Aórtica/complicações , Estenose da Valva Aórtica/diagnóstico , Estenose da Valva Aórtica/mortalidade , Estenose da Valva Aórtica/cirurgia , Cateterismo Cardíaco/métodos , Feminino , Próteses Valvulares Cardíacas , Humanos , Japão/epidemiologia , Cirrose Hepática/complicações , Cirrose Hepática/diagnóstico , Cirrose Hepática/epidemiologia , Masculino , Avaliação de Processos e Resultados em Cuidados de Saúde , Complicações Pós-Operatórias/diagnóstico , Complicações Pós-Operatórias/etiologia , Complicações Pós-Operatórias/mortalidade , Desenho de Prótese , Estudos Retrospectivos , Medição de Risco , Fatores de Risco , Índice de Gravidade de Doença , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/instrumentação , Substituição da Valva Aórtica Transcateter/métodos
9.
Circ J ; 82(8): 2191-2198, 2018 07 25.
Artigo em Inglês | MEDLINE | ID: mdl-29311518

RESUMO

BACKGROUND: Various frailty markers have been developed to guide better patient selection for transcatheter aortic valve implantation (TAVI). This study aimed to investigate the frequency and specific causes of unplanned hospital readmission after TAVI, and to investigate which frailty markers better predicted outcomes.Methods and Results:We retrospectively reviewed 155 patients for whom we calculated their Short Physical-Performance Battery (SPPB), Placement of AoRTic TraNscathetER Valve (PARTNER) frailty scale, frailty index, clinical frailty scale, modified Fried scale, and gait speed. The primary endpoint was unplanned readmission following TAVI. The clinical model was established using variables that were identified as independent predictors in multivariate analysis. Incremental values were assessed after adding each frailty marker to the clinical model, and were compared between frailty markers. Although unplanned readmission <30 days was 1.9%, 23% of patients had an unplanned readmission following TAVI mainly because of heart failure and pneumonia within 1 year. Frailty markers other than the modified Fried scale were independently associated with unplanned readmission. The SPPB and the PARTNER frailty scale significantly increased discriminatory performance for predicting unplanned readmission. CONCLUSIONS: Unplanned readmissions following TAVI in the present study were fewer than previously reported. There seems to be a difference between frailty markers in their predictive performance. Precise frailty assessment may result in reducing unplanned admissions after TAVI and therefore better quality of life.


Assuntos
Fragilidade/diagnóstico , Readmissão do Paciente , Substituição da Valva Aórtica Transcateter/tendências , Idoso , Idoso de 80 Anos ou mais , Biomarcadores/análise , Feminino , Insuficiência Cardíaca/etiologia , Humanos , Masculino , Pneumonia/etiologia , Estudos Retrospectivos , Medição de Risco , Substituição da Valva Aórtica Transcateter/efeitos adversos
10.
Heart Vessels ; 33(11): 1343-1349, 2018 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-29721672

RESUMO

Transcatheter aortic valve implantation (TAVI) has been established as a low-invasive therapy for aortic stenosis, but circulatory collapse necessitating mechanical circulatory support could occur during TAVI due to procedure itself or procedural complications. The purpose of this study is to describe the outcomes of patients requiring extracorporeal membrane oxygenation (ECMO) in TAVI. Among 384 consecutive patients undergoing TAVI from April 2010 to July 2017 in Sakakibara Heart Institute, we evaluated seven patients (1.8%) who required ECMO during procedure. The definitions of outcome were derived from Valve Academic Research Consortium-2 criteria. The indication of ECMO included bridge to emergent surgery due to mechanical complication (n = 3) [aortic root rupture (n = 2), and left-ventricle rupture (n = 1); emergent use], bridge to recovery from cardiac stunning (n = 3; emergent use), and circulatory support for cardiogenic shock (n = 1; prophylactic use). All patients were cannulated from femoral artery and vein, and there was no ECMO-related complication. Six out of seven patients were weaned from ECMO during the TAVI procedure, whereas the other patient with annulus rupture died the following day after TAVI. Five patients survived to discharge [postoperative hospital stay: 27.6 ± 24.3 (23) days]. During mean follow-up of 253 days, a total of three patients died due to annulus rupture, refractory heart failure, and pneumonia, respectively. ECMO is effective and a safe mechanical support device during TAVI. The mid-term outcomes of patients who needed ECMO were unfavorable. Further evolution of transcatheter heart valve is essential, and prophylactic ECMO may contribute to better prognosis in selected patients.


Assuntos
Estenose da Valva Aórtica/cirurgia , Valva Aórtica/cirurgia , Oxigenação por Membrana Extracorpórea/métodos , Próteses Valvulares Cardíacas , Complicações Pós-Operatórias/epidemiologia , Medição de Risco , Substituição da Valva Aórtica Transcateter/métodos , Idoso de 80 Anos ou mais , Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/diagnóstico , Feminino , Seguimentos , Humanos , Incidência , Japão/epidemiologia , Masculino , Prognóstico , Estudos Retrospectivos , Fatores de Risco , Taxa de Sobrevida/tendências , Fatores de Tempo , Resultado do Tratamento
11.
Int Heart J ; 59(6): 1469-1472, 2018 Nov 28.
Artigo em Inglês | MEDLINE | ID: mdl-30249922

RESUMO

The therapeutic role of transcatheter aortic valve implantation (TAVI) in high surgical risk or inoperable cases has been established. Most of the candidates for TAVI are elderly and have multiple comorbidities including chronic kidney disease. However, contrast-enhanced computed tomography and coronary angiography, both of which require iodine contrast media, are essential for pre-procedural planning. In addition, TAVI could have adverse effects on kidney function including contrast media-induced nephrotoxicity. Acute kidney injury following TAVI has been reported to be related to poor prognosis. In a case with advanced renal dysfunction, we successfully avoided post-procedural acute kidney injury by performing pre-procedural evaluation using minimal contrast and TAVI without contrast media. If anatomical conditions and experiences of the heart team are adequate, renoprotective TAVI should be a favorable therapy for patients with aortic stenosis complicated by renal dysfunction.


Assuntos
Injúria Renal Aguda/prevenção & controle , Estenose da Valva Aórtica/cirurgia , Complicações Pós-Operatórias/prevenção & controle , Insuficiência Renal Crônica/complicações , Substituição da Valva Aórtica Transcateter/métodos , Injúria Renal Aguda/etiologia , Idoso de 80 Anos ou mais , Estenose da Valva Aórtica/complicações , Meios de Contraste/efeitos adversos , Humanos , Masculino , Complicações Pós-Operatórias/etiologia
14.
Heart Vessels ; 32(10): 1236-1243, 2017 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-28536830

RESUMO

Transcatheter aortic valve implantation (TAVI) is recommended for patients who are inoperable or at high risk for surgical aortic valve replacement (SAVR). Corticosteroid therapy is considered to be a risk factor for SAVR, but there is a paucity of information about TAVI in patients taking corticosteroids. The aim of this study is to elucidate the outcome of TAVI in patients on chronic corticosteroid therapy, compared with SAVR. We retrospectively analyzed patients on corticosteroid therapy who underwent TAVI (n = 21) or SAVR (n = 30) for severe aortic stenosis in Sakakibara Heart Institute. Primary outcome was a 30-day composite endpoint consisting of early safety endpoints (death, stroke, life-threatening bleeding, acute kidney injury, coronary obstruction, major vascular complication, and valve-related dysfunction) and corticosteroid-specific endpoints (adrenal insufficiency, sepsis, and hyperglycemic complication). There were no differences between two groups in background factors, other than patient age and serum albumin level (age 81.0 ± 5.5 vs. 74.7 ± 9.9 years, p = 0.0061, albumin 3.6 ± 0.4 vs. 4.0 ± 0.4 g/dl, p = 0.0076). Device success rate for TAVI was 95.2%. In TAVI group, operative time was shorter (100.2 ± 46.2 vs. 250.0 ± 92.2 min, p < 0.0001), and the amount of blood transfusion was less (0.67 ± 1.8 vs. 3.5 ± 2.4 units, p < 0.0001) than in SAVR group. There was no difference in primary outcome (19.0 vs. 20.0%, p = 1.0). Rate of prosthesis-patient mismatch was lower in TAVI group (4.8 vs. 33.3%, p = 0.017), and no moderate or severe post-procedural aortic regurgitation was observed in both groups. The post-procedural survival was similar in the two groups (p = 0.67, mean follow-up 986 ± 922 days). TAVI may be a viable therapeutic option in patients taking corticosteroids.


Assuntos
Corticosteroides/administração & dosagem , Estenose da Valva Aórtica/terapia , Valva Aórtica , Implante de Prótese de Valva Cardíaca/efeitos adversos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Injúria Renal Aguda/etiologia , Corticosteroides/efeitos adversos , Fatores Etários , Idoso , Idoso de 80 Anos ou mais , Insuficiência da Valva Aórtica/etiologia , Análise de Falha de Equipamento , Feminino , Próteses Valvulares Cardíacas , Humanos , Japão , Masculino , Estudos Retrospectivos , Medição de Risco , Acidente Vascular Cerebral/etiologia , Resultado do Tratamento
15.
J Cardiol Cases ; 29(1): 1-4, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-38188312

RESUMO

The 23-valent pneumococcal polysaccharide vaccine (PPSV23) has contributed to reducing pneumonia caused by Streptococcus pneumoniae. However, in Japan, invasive pneumococcal diseases caused by non-vaccine-covered serotypes have increased over the years. A 73-year-old man with a history of PPSV23 was referred to our hospital due to persistent fever and back pain following pneumococcal pneumonia. Contrast-enhanced computed tomography revealed an infectious aneurysm (IAA) at the distal part of the aortic arch. The patient was surgically treated with in situ aortic reconstruction and administered antibiotics. On pathogenic examination of the resected IAA, atherosclerotic changed aortic wall, neutrophil infiltration, and abscesses were observed. Although multiple blood culture tests were negative, tissue culture tests and 16S ribosomal RNA gene-based polymerase chain reaction identified S. pneumoniae. According to capsular polysaccharide synthesis B gene-based serotyping, the serotype was identified as 23A, which is not covered with PPSV23. Serotype 23 is among the most frequently identified serotypes in recent years and associated with in-hospital mortality. Although several pneumococcal serotypes are responsible for lethal infections, the association between these serotypes and disease is uncertain. Further studies on the association between pneumococcal serotypes and IAA, and the development of a broader-covered vaccine are required. Learning objective: •To be able to make a differential diagnosis of invasive pneumococcal pneumonia in patients with persistent fever and newly emerging back pain following pneumococcal infection.•To understand the importance of combining culture tests and molecular analysis to diagnose invasive pneumococcal diseases accurately.•To understand the threat of non-vaccine-covered serotypes even in patients with vaccination histories because the vaccine is limited to only one-fourth of all pneumococcal serotypes.

16.
Am J Cardiol ; 211: 1-8, 2024 Jan 15.
Artigo em Inglês | MEDLINE | ID: mdl-37884114

RESUMO

The number of patients who underwent transcatheter aortic valve implantation (TAVI) with the potential for reintervention is steadily increasing; however, there is a risk of sinus sequestration (SS) during a redo TAVI. The prevalence, predictors, and risk stratification of the risk for SS remain uncertain. We analyzed computed tomography acquired from 263 patients who underwent TAVI between 2021 and 2022: balloon-expandable valve (BEV) (71%) and self-expandable valve (SEV) (29%). Patients were considered at risk for SS if they met the following: (1) BEV frame > sinotubular junction (STJ) or SEV neocommissure greater than the STJ and (2) valve-to-STJ <2 mm. The risk of left, right, and any SS in 51%, 50%, and 65%, respectively, did not differ between BEV and SEV. The predictors of any SS were the height of the left and right coronary cusp (odds ratio [OR] 0.81 and 0.71, cutoff 18.6 and 19.2 mm, respectively) and STJ minus the annulus diameter (OR 0.65, cutoff 3.7 mm) in BEV, and STJ diameter (OR 0.47, cutoff 27.6 mm) in SEV. The number of predictors stratified the risk of any SS: low risk with BEV at 0 predictors (14% at risk of SS), intermediate risk at 1 predictor (65%), high risk at 2 or 3 predictors (81% and 95%), and low risk with SEV at 0 predictors (33%) versus high risk at 1 predictor (91%). In conclusion, 2/3 of patients who underwent TAVI were at risk of SS. The height of the coronary cusp and the STJ diameter were associated with and adequately stratified the risk of SS.


Assuntos
Estenose da Valva Aórtica , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Humanos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/métodos , Estenose da Valva Aórtica/epidemiologia , Estenose da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/etiologia , Prevalência , Valva Aórtica/cirurgia , Medição de Risco , Desenho de Prótese , Resultado do Tratamento
17.
Cardiovasc Interv Ther ; 39(1): 57-64, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37231235

RESUMO

Low body weight and advanced age are reported to be among the best predictors of osteoporosis, and osteoporosis self-assessment tool (OST) values are calculated using a simple formula to identify postmenopausal women at increased risk of osteoporosis. In our recent study, we demonstrated an association between fractures and poor outcomes in postmenopausal women following transcatheter aortic valve replacement (TAVR). In this study, we aimed to investigate the osteoporotic risk in women with severe aortic stenosis and determined whether an OST could predict all-cause mortality following TAVR. The study population comprised 619 women who underwent TAVR. Compared to a quarter of patients with diagnosis of osteoporosis, 92.4% of participants were at high risk of osteoporosis based on OST criteria. When divided into tertiles based on OST values, patients in tertile 1 (lowest OST) displayed increased frailty, a higher incidence of multiple fractures, and greater Society of Thoracic Surgeons scores. Estimated all-cause mortality survival rates 3 years post-TAVR were 84.2 ± 3.0%, 89.5 ± 2.6%, and 96.9 ± 1.7% for OST tertiles 1, 2, and 3, respectively (p = 0.001). Multivariate analysis showed that the OST tertile 3 was associated with decreased risk of all-cause mortality compared with OST tertile 1 as the referent. Notably, a history of osteoporosis was not associated with all-cause mortality. Patients with high osteoporotic risk are highly prevalent among those with aortic stenosis according to the OST criteria. OST value is a useful marker for predicting all-cause mortality in patients undergoing TAVR.


Assuntos
Estenose da Valva Aórtica , Osteoporose , Substituição da Valva Aórtica Transcateter , Humanos , Feminino , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento , Fatores de Risco , Estenose da Valva Aórtica/complicações , Osteoporose/complicações , Osteoporose/cirurgia , Valva Aórtica/cirurgia
18.
J Cardiol ; 83(3): 155-162, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-37517607

RESUMO

BACKGROUND: When frailty is considered in patient selection, better outcomes are achieved in transcatheter aortic valve replacement (TAVR) procedures. This study investigated whether patient photographs could be utilized to qualitatively assess patient frailty and independently predict poor outcomes following TAVR. METHODS: This study included 1345 patients with severe aortic stenosis who underwent TAVR at the Sakakibara Heart Institute, Japan, between 2013 and 2022. Patient photographs were taken prior to the initial outpatient clinic examination or at discharge in case the patient's first visit was unplanned admission. Frailty was assessed from patient photographs using a four-point photographic frailty scale; 1 (non-frail), 2 (vulnerable), 3 (mild frail), and 4 (frail). Photographic frailty scale of 3 and 4 were defined as high. The primary endpoint was all-cause mortality following TAVR. RESULTS: Seven hundred ninety-six patients who had their facial photographs taken within six months before the TAVR procedure were analyzed. Patients with a higher photographic frailty scale belonged to New York Heart Association classes III/IV, and had higher Society of Thoracic Surgeons scores, higher incidence of wheelchair usage, lower hemoglobin, and smaller aortic valve areas. According to the frailty assessment, patients with a higher photographic frailty scale exhibited slower performance in the 5-m walk test, reduced hand grip strength, more severe dementia, had a higher clinical frailty scale, and lower serum albumin level. Multivariable Cox regression analysis revealed that the high photographic frailty scale was independently associated with all-cause mortality (adjusted hazard ratio 1.62, 95 % confidence interval 1.12-2.33, p = 0.010). Kaplan-Meier analysis indicated that patients with high photographic frailty scale had higher all-cause mortality rates compared to those with low scale (log-rank p = 0.011). CONCLUSIONS: Patient registration photographs can be used to obtain qualitative assessments of frailty in severe aortic stenosis cases, and such assessments can independently predict poor outcomes following TAVR.


Assuntos
Estenose da Valva Aórtica , Fragilidade , Substituição da Valva Aórtica Transcateter , Humanos , Substituição da Valva Aórtica Transcateter/métodos , Fragilidade/diagnóstico , Fragilidade/complicações , Estenose da Valva Aórtica/complicações , Força da Mão , Resultado do Tratamento , Fatores de Risco , Valva Aórtica/cirurgia
19.
Cardiovasc Interv Ther ; 39(4): 460-467, 2024 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-38755510

RESUMO

Low body weight and advanced age are among the best predictors of osteoporosis. Osteoporosis Self-Assessment Tool (OST) values are calculated by a simple formula [(body weight in kilograms - age in years) × 0.2] to identify patients at increased risk of osteoporosis. In our recent single-center study, we demonstrated an association between OST and poor outcomes in postmenopausal women after transcatheter aortic valve replacement (TAVR). We aimed to investigate the impact of osteoporotic risk in men with aortic stenosis who underwent TAVR in a large cohort. In this multi-center study, 1,339 men who underwent TAVR between April 2010 and July 2023 were retrospectively analyzed. Women were excluded from the present study. All patients were deemed appropriate for TAVR after a review by a multidisciplinary team. Baseline characteristics of patients were compared by dividing patients into three tertiles, based on the OST value: ≤ - 6.16, - 6.16 to - 4.14, and - 4.14 < for tertiles 1, 2, and 3, respectively. Primary endpoint was all-cause mortality after TAVR. Tertile 1 (patients with the lowest OST values) included older patients with smaller body mass index, lower hemoglobin and albumin levels. In addition, they had greater clinical frailty scale, slower 5-meter walk test, weaker hand grip strength, and more cognitive impairment, indicating increased frailty. They were more severely symptomatic, with lower ejection fractions, smaller aortic valve areas, and more tricuspid regurgitation than were patients in the other two groups. Multivariate analysis revealed that OST tertiles 3 was associated with decreased risk of all-cause mortality (hazard ratio, 0.66; 95% confidence interval, 0.48-0.90), compared with OST tertile 1 as a reference. For OST tertiles 1, 2, and 3, the estimated 1-year survival rates of all-cause mortality post-TAVR were 83.6% ± 1.9%, 91.1% ± 1.4%, and 93.1% ± 1.3%, respectively, (log-rank, p < 0.001). In conclusions, in men as same as women, osteoporotic risk assessed by OST values was overlapped with increased frailty. The simple OST formula was useful for predicting all-cause mortality in patients undergoing TAVR in large registry datasets.


Assuntos
Estenose da Valva Aórtica , Osteoporose , Sistema de Registros , Substituição da Valva Aórtica Transcateter , Humanos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Masculino , Estenose da Valva Aórtica/cirurgia , Estudos Retrospectivos , Idoso de 80 Anos ou mais , Idoso , Fatores de Risco , Medição de Risco/métodos
20.
ESC Heart Fail ; 2024 Sep 23.
Artigo em Inglês | MEDLINE | ID: mdl-39308333

RESUMO

AIMS: Mitral transcatheter edge-to-edge repair (M-TEER) is a valid treatment option for severe mitral regurgitation (MR), necessitating accurate risk stratification of M-TEER candidates for effective patient selection, optimal periprocedural care and improved long-term outcomes. The body mass index (BMI) is a simple and practical prognostic index, and the obesity paradox has been widely reported. METHODS AND RESULTS: Between April 2018 and June 2021, 2149 patients undergoing M-TEER were registered in the prospective multicentre registry and classified into three groups: underweight (BMI < 18.5 kg/m2), normal weight (18.5 â‰¦ BMI < 25 kg/m2) and overweight and obese (25 kg/m2 â‰¦ BMI). The impact of underweight on the all-cause, cardiovascular and non-cardiovascular mortality following M-TEER was evaluated [follow-up duration: 436 (363-733) days]. The participants (median BMI: 21.1 kg/m2) were categorized as underweight (n = 450, 20.9%), normal weight (n = 1409, 65.6%) and overweight and obese (n = 290, 13.5%). Compared with the other two groups, the underweight group exhibited several negative prognostic factors, including older age, frailty, no dyslipidaemia, hypoalbuminaemia, residual MR and non-home discharge. Underweight patients had the highest rate of all-cause, cardiovascular and non-cardiovascular mortality, whereas those in the other two groups were similar. As per the multivariate analysis, underweight itself was associated with all-cause mortality (hazard ratio: 1.52, 95% confidence interval: 1.17-1.97, P = 0.009) and cardiovascular mortality (hazard ratio: 1.45, 95% confidence interval: 1.04-2.01, P = 0.028). CONCLUSIONS: Underweight patients had the highest mortality rate after M-TEER. Comorbidities, residual MR, discharge disposition and underweight status were correlated with postprocedural outcome.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA