1.
Anal Bioanal Chem ; 397(5): 1821-9, 2010 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-20425107

RESUMO

We report the use of paper-based microfluidic devices fabricated from a novel polymer blend for the monitoring of urinary ketones, glucose, and salivary nitrite. Paper-based devices were fabricated via photolithography in less than 3 min and were immediately ready for use for these diagnostically relevant assays. Patterned channels on filter paper as small as 90 microm wide with barriers as narrow as 250 microm could be reliably patterned to permit and block fluid wicking, respectively. Colorimetric assays for ketones and nitrite were adapted from the dipstick format to this paper microfluidic chip for the quantification of acetoacetate in artificial urine, as well as nitrite in artificial saliva. Glucose assays were based on those previously demonstrated (Martinez et al., Angew Chem Int Ed 8:1318-1320, 1; Martinez et al., Anal Chem 10:3699-3707, 2; Martinez et al., Proc Nat Acad Sci USA 50:19606-19611, 3; Lu et al., Electrophoresis 9:1497-1500, 4; Abe et al., Anal Chem 18:6928-6934, 5). Reagents were spotted on the detection pad of the paper device and allowed to dry prior to spotting of samples. The ketone test was a two-step reaction requiring a derivitization step between the sample spotting pad and the detection pad, thus for the first time, confirming the ability of these paper devices to perform online multi-step chemical reactions. Following the spotting of the reagents and sample solution onto the paper device and subsequent drying, color images of the paper chips were recorded using a flatbed scanner, and images were converted to CMYK format in Adobe Photoshop CS4 where the intensity of the color change was quantified using the same software. The limit of detection (LOD) for acetoacetate in artificial urine was 0.5 mM, while the LOD for salivary nitrite was 5 microM, placing both of these analytes within the clinically relevant range for these assays. Calibration curves for urinary ketone (5 to 16 mM) and salivary nitrite (5 to 2,000 microM) were generated. The time of device fabrication to the time of test results was about 25 min.


Assuntos
Glucose/análise , Cetonas/urina , Técnicas Analíticas Microfluídicas/métodos , Nitritos/análise , Saliva/química , Humanos , Técnicas Analíticas Microfluídicas/instrumentação
2.
Electrophoresis ; 30(18): 3160-7, 2009 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-19722198

RESUMO

We have developed a new method for analyte preconcentration on a microfluidic device using a porous membrane fabricated via sol-gel chemistry. These porous membranes were fabricated within the channels of glass microfluidic devices exploiting laminar flow to bring an alcoholic sol-gel precursor (titanium isopropoxide in 2-propanol) into contact with an alcohol-water solution at a channel cross intersection. These two streams reacted at the fluidic interface to form a porous titania membrane. The thickness of the membrane could be altered by changing the [H2O]. Analyte concentration was accomplished by applying a voltage across the titania membrane. The level of analyte enrichment was monitored, and enrichment factors of above 4000 in 400 s were obtained for 2,7-dichlorofluorescein.


Assuntos
Eletroforese/instrumentação , Eletroforese/métodos , Membranas Artificiais , Técnicas Analíticas Microfluídicas/instrumentação , Técnicas Analíticas Microfluídicas/métodos , Titânio/química , Fluoresceínas/isolamento & purificação , Íons/química , Microscopia de Fluorescência , Transição de Fase , Fosfatos/química , Porosidade , Reprodutibilidade dos Testes
3.
Electrophoresis ; 29(24): 4900-5, 2008 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-19130569

RESUMO

A new buffer has been developed for fast, high-efficiency separations of amino acids by MEKC. This buffer was more environmentally friendly than the most commonly used surfactant-containing buffers for MEKC separations. It used a commercially available dishwashing soap by Seventh Generation (Burlington, VT, USA), which contained three micelle-forming agents. The mixed micelles were composed of sodium lauryl ether sulfate (anionic), cocamidopropyl betaine (zwitterionic), and cocamide monoethanolamine (non-ionic). The optimized buffer contained 5.0% w/w Seventh Generation Free & Clear dishwashing soap, 10 mM sodium borate, and was completely void of organics. The lack of organics and the biodegradability of the surfactant molecules made this buffer more environmentally friendly than typical SDS-containing buffers. This new buffer also had a different selectivity and provided faster separations with higher separation efficiencies than SDS-based buffers. Fast separations of BODIPY FL labeled amino acids yielded peaks with separation efficiencies greater than 100,000 in less than 20 s.


Assuntos
Betaína/análogos & derivados , Cromatografia Capilar Eletrocinética Micelar/instrumentação , Etanolaminas/química , Técnicas Analíticas Microfluídicas/instrumentação , Polietilenoglicóis/química , Tensoativos/química , Aminoácidos/análise , Betaína/química , Soluções Tampão , Cromatografia Capilar Eletrocinética Micelar/métodos , Eletroforese em Microchip/métodos , Micelas , Técnicas Analíticas Microfluídicas/métodos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA