Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Mais filtros

Base de dados
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
RSC Adv ; 10(68): 41393-41402, 2020 Nov 11.
Artigo em Inglês | MEDLINE | ID: mdl-35516538

RESUMO

Photocatalysis is a promising technique for developing sustainable and environmentally friendly materials to improve indoor air quality. Visible-light-responsive TiO2 has been widely investigated but there are inconsistent results because photocatalytic properties depend strongly on synthetic methods. Herein, we synthesize TiO2 doped with 10 different metal ions (M-TiO2) by conducting a dialysis in a sol-gel method to obtain the best photocatalyst for the degradation of acetaldehyde under LED irradiation. Purification of a sol by dialysis enables us to discuss pure effects of dopants on the photocatalytic activity because impurities such as counter ions of metal salts are removed before sintering. Only Cr-, Pt-, V-, and Fe-TiO2 show photocatalytic activity and the optimal doping amounts are 0.50-1.7, 0.10, 1.0, and 0.10 atom%, respectively. Such differences in the optimal amounts can be explained in terms of the dopant ions having different valence states, suggesting the formation of oxygen vacancies. The Cr-TiO2 powder exhibits high activity even at the doping amount of 4.2 atom%. We also demonstrate that the Cr-TiO2 film prepared on a glass substrate can be used to degrade acetaldehyde by changing the film thickness and the LED intensity depending on the degree of the indoor contamination.

2.
ACS Appl Mater Interfaces ; 10(23): 19889-19896, 2018 Jun 13.
Artigo em Inglês | MEDLINE | ID: mdl-29767503

RESUMO

Tungsten oxide-based photochromic films that change reversibly in air between colorless-transparent in the dark and dark blue under UV irradiation were prepared by using methylcellulose as a film matrix and various dispersants. Alpha-hydroxyl acid such as glycolic acid (GA) or glyceric acid (GlyA) is the best dispersant because it can make the film transparent by adding a small quantity much less than that of 3-hydroxypropionic acid or ethylene glycol. Fourier-transform infrared spectra and Raman spectra indicate that a strong interaction exists between WO3 and GA or GlyA. The coloration and bleaching processes of the prepared films were investigated to clarify the effect of the dispersants and the moisture contents. The bleaching rate remarkably decreased in the films containing GA or GlyA but accelerated by increasing the contact with O2. Measurements of electron-spin resonance reveals that GA and GlyA as dispersants stabilize the W5+ state. This paper shows that the coloring rate and the period for keeping the blue-colored state are tunable by changing the dispersants. The photochromic films containing α-hydroxyl acid as the dispersant have the potential for application as rewritable film on which information displayed with blue-colored state can be clearly readable for longer times compared with other dispersants.

3.
Anal Sci ; 21(3): 241-5, 2005 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-15790106

RESUMO

The analysis of tetracycline, oxytetracyline, chlortetracycline and doxycycline by high-performance liquid chromatography with pulsed amperometric detection using an anodized boron-doped diamond thin film (BDD) electrode is originally reported. The analyses were carried out using the mobile phase, phosphate buffer (0.01 M, pH 2.5)-acetonitrile (80:20; v/v), on a C18 column (250 x 4.6 mm i.d., 5 microm) at a flow rate of 1.0 mL/min. The optimal PAD waveform parameters at the anodized BDD were 1.5 V (versus Ag/AgCl) detection potential (E(det)) for 290 ms (200 ms delay time and 90 ms integration time), 2.0 V (versus Ag/AgCl) oxidation potential (E(oxd)) for 200 ms oxidation time (t(oxd)) and 0.4 V (versus Ag/AgCI) reduction potential (E(red)) for 200 ms reduction time (t(red)). The proposed method showed the simultaneous determination of tetracycline, oxytetracyline, chlortetracycline and doxycycline with a linear range of 0.1 - 100 microg/mL, detection limits of 0.05 - 0.1 microg/mL and recoveries of 70.8 - 96.0%. The application of this method to real samples was demonstrated and validated using a shrimp sample.


Assuntos
Antibacterianos/análise , Antibacterianos/química , Cromatografia Líquida de Alta Pressão/métodos , Eletroquímica/métodos , Tetraciclinas/análise , Tetraciclinas/química , Animais , Decápodes/química , Eletrodos
4.
Anal Sci ; 28(2): 127-33, 2012.
Artigo em Inglês | MEDLINE | ID: mdl-22322804

RESUMO

Electrochemical detection of sugar-related compounds was conducted using a boron-doped diamond (BDD) electrode as a detector for flow-injection analysis (FIA). Sugar-related compounds oxidize at high applied potentials, for which the BDD electrode is suitable for electrochemical measurements. Conditions for an FIA system with a BDD detector were optimized, and the following detection limits were achieved for sugar-related compounds: monosaccharides, 25-100 pmol; sugar alcohols, 10 pmol; and oligosaccharides, 10 pmol. The detection limit for monosaccharide D-glucose (Glu) was 105 pmol (S/N = 3). A linear range was acquired from the detection limit to 50 nmol, and the relative standard deviation was 0.65% (20 nmol, n = 6). A high-performance liquid chromatography (HPLC) column was added to the system between the sample injector and the detector and detection limits to the picomole level were achieved, which is the same for the HPLC system and the FIA system. The electrochemical oxidation reaction of Glu was examined using cyclic voltammetry with the BDD detector. The reaction proved to be irreversible, and proceeded according to the following two-step mechanism: (1) application of a high potential (2.00 V vs. Ag/AgCl) to the electrode causes water to electrolyze on the electrode surface with the simultaneous generation of a hydroxyl radical on the surface, and (2) the hydroxyl radical indirectly oxidizes Glu. Thus, Glu can be detected by an increase in the oxidation current caused by reactions with hydroxy radicals.


Assuntos
Boro/química , Carboidratos/análise , Diamante/química , Eletroquímica/métodos , Álcoois/análise , Álcoois/química , Soluções Tampão , Carboidratos/química , Cromatografia Líquida de Alta Pressão , Eletroquímica/instrumentação , Eletrodos , Análise de Injeção de Fluxo , Limite de Detecção , Oxirredução , Prata/química , Compostos de Prata/química
5.
Langmuir ; 24(14): 7545-8, 2008 Jul 15.
Artigo em Inglês | MEDLINE | ID: mdl-18547082

RESUMO

Crystal-face-selective adsorption of Au nanoparticles (AuNPs) was achieved on polycrystalline boron-doped diamond (BDD) surface via the self-assembly method combined with a UV/ozone treatment. To the best of our knowledge, this is the first report of crystal-face-selective adsorption on an inorganic solid surface. Hydrogen-plasma-treated BDD samples and those followed by UV/ozone treatment for 2 min or longer showed almost no adsorption of AuNP after immersion in the AuNP solution prepared by the citrate reduction method. However, the samples treated by UV/ozone for 10 s showed AuNP adsorption on their (111) facets selectively after the immersion. Moreover, the sample treated with UV/ozone for 40-60 s showed AuNP adsorption on the whole surface. These results indicate that the AuNP adsorption behavior can be controlled by UV/ozone treatment time. This phenomenon was highly reproducible and was applied to a two-step adsorption method, where AuNPs from different batches were adsorbed on the (111) and (100) surface in this order. Our findings may be of great value for the fabrication of advanced nanoparticle-based functional materials via bottom-up approaches with simple macroscale procedures.


Assuntos
Diamante/química , Ouro/química , Nanopartículas Metálicas/química , Adsorção , Cristalização , Nanopartículas Metálicas/ultraestrutura , Microscopia Eletrônica de Varredura , Propriedades de Superfície
6.
Talanta ; 71(2): 648-55, 2007 Feb 15.
Artigo em Inglês | MEDLINE | ID: mdl-19071355

RESUMO

Highly boron-doped diamond (BDD) electrode, have been examined for simultaneous detection of purine and pyrimidine bases in mild acidic media by using HPLC with amperometric detection. Cyclic voltammetry at as-deposited (AD) and anodically oxidized (AO) BDD were used to study the electrochemistry and to optimize the condition for HPLC applications. At AO BDD electrode, due to its higher overpotential of oxygen evolution reaction, well-defined anodic peaks were observed for the oxidation of purine and pyrimidine bases in acid medium, whereas at AD BDD the oxidation peak of thymine was overlapped with the anodic current of oxygen evolution. The chromatograms of adenine, guanine, cytosine, thymine and 5-methylcytosine mixture were well resolved by using a silica-based column and a solution of 5% acetonitrile in 100mM ammonium acetate buffer (pH 4.25) as the mobile phase. The detection was carried out at AO BDD electrode at an applied potential of 1.6V versus Ag/AgCl. Linear calibration curves were obtained within the concentration range from 0.1 to 10microM with the limits of detection (S/N=3) ranging from 26.3 to 162.1nM, resulting in an order of magnitude higher sensitivities than those at conventional electrodes. HPLC analysis with diamond amperometric detector was successfully applied for determination of 5-methylcytosine in real DNA samples with high reproducibility. No deactivation of the electrode was found during cyclic voltammetric and HPLC measurements, indicating the high stability for analysis of biological samples.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA