RESUMO
BACKGROUND: Although current human papillomavirus (HPV) genotype screening tests identify genotypes 16 and 18 and do not specifically identify other high-risk types, a new extended genotyping test identifies additional individual (31, 45, 51, and 52) and groups (33/58, 35/39/68, and 56/59/66) of high-risk genotypes. METHODS: We developed a Markov model of the HPV disease course and evaluated the clinical and economic value of HPV primary screening with Onclarity (BD Diagnostics, Franklin Lakes, NJ) capable of extended genotyping in a cohort of women 30 years or older. Women with certain genotypes were later rescreened instead of undergoing immediate colposcopy and varied which genotypes were rescreened, disease progression rate, and test cost. RESULTS: Assuming 100% compliance with screening, HPV primary screening using current tests resulted in 25,194 invasive procedures and 48 invasive cervical cancer (ICC) cases per 100,000 women. Screening with extended genotyping (100% compliance) and later rescreening women with certain genotypes averted 903 to 3163 invasive procedures and resulted in 0 to 3 more ICC cases compared with current HPV primary screening tests. Extended genotyping was cost-effective ($2298-$7236/quality-adjusted life year) when costing $75 and cost saving (median, $0.3-$1.0 million) when costing $43. When the probabilities of disease progression increased (2-4 times), extended genotyping was not cost-effective because it resulted in more ICC cases and accrued fewer quality-adjusted life years. CONCLUSIONS: Our study identified the conditions under which extended genotyping was cost-effective and even cost saving compared with current tests. A key driver of cost-effectiveness is the risk of disease progression, which emphasizes the need to better understand such risks in different populations.
Assuntos
Alphapapillomavirus , Infecções por Papillomavirus , Displasia do Colo do Útero , Neoplasias do Colo do Útero , Análise Custo-Benefício , Detecção Precoce de Câncer , Feminino , Genótipo , Humanos , Papillomaviridae/genética , Infecções por Papillomavirus/diagnóstico , Infecções por Papillomavirus/epidemiologia , GravidezRESUMO
A systematic review appraising the clinical performance and safety of the primary SIGMA modular knee system (DePuy-Synthes, Warsaw, Ind.) found 5 registry reports and 53 journal publications reporting survivorship or postoperative increase in Knee Society scores on 241632 primary SIGMA knee arthroplasties. Pooled data from national joint registries and clinical studies on primary SIGMA knee survivorship were comparable. Both were higher than for all other knees in 5 national joint registries up to 5 years. Compared with pooled data from 2 independent systematic reviews of primary non-SIGMA knees, the SIGMA system provided comparable postoperative changes in Knee Society knee score and a nonsignificant trend of higher postoperative changes in Knee Society function score. This finding suggests that this knee system provides excellent durable results.
Assuntos
Artroplastia do Joelho/métodos , Articulação do Joelho/cirurgia , Desenho de Prótese , Idoso , Idoso de 80 Anos ou mais , Feminino , Seguimentos , Humanos , Articulação do Joelho/fisiopatologia , Prótese do Joelho , Masculino , Pessoa de Meia-Idade , Período Pós-Operatório , Sistema de Registros , Reoperação , Taxa de Sobrevida , Resultado do TratamentoRESUMO
A systematic search identified 29 papers reporting survivorship and clinical and function Knee Society Scores (KSS) of 6437 total knee replacements using the Low Contact Stress (LCS) Rotating Platform (RP) mobile bearing knee. Low Contact Stress RP survivorship and KSS outcomes were compared with non-LCS knees in the Swedish knee registry at comparable time periods and in 2 independent systematic reviews of knee arthroplasty outcomes. There is a substantial body of mainly observational evidence supporting the LCS RP knee. Knee Society Score outcomes were comparable for LCS RP and non-LCS RP knees at up to 15 years of follow-up, with mean clinical and function scores ranging from 72 to 96 and 58 to 90, respectively. Survivorship of LCS RP knees up to 14 years was higher than that for all knees in the Swedish Knee Registry.
Assuntos
Artroplastia do Joelho , Prótese do Joelho , Desenho de Prótese , Seguimentos , Humanos , Reoperação , Análise de Sobrevida , Resultado do TratamentoRESUMO
BACKGROUND: A tubeless, on-body automated insulin delivery (AID) system (Omnipod 5 Automated Insulin Delivery System) demonstrated improved glycated hemoglobin A1c levels and increased time in range (70 mg/dL to 180 mg/dL) for both adults and children with type 1 diabetes in a 13-week multicenter, single-arm study. OBJECTIVE: To assess the cost-effectiveness of the tubeless AID system compared with standard of care (SoC) in the management of type 1 diabetes (T1D) in the United States. METHODS: Cost-effectiveness analyses were conducted from a US payer's perspective, using the IQVIA Core Diabetes Model (version 9.5), with a time horizon of 60 years and an annual discount of 3.0% on both costs and effects. Simulated patients received either tubeless AID or SoC, the latter being defined as either continuous subcutaneous insulin infusion (86% of patients) or multiple daily injections. Two cohorts (children: <18 years; adults: ≥18 years) of patients with T1D and 2 thresholds for nonsevere hypoglycemia (nonsevere hypoglycemia event [NSHE] <54 mg/dL and <70 mg/dL) were considered. Baseline cohort characteristics and treatment effects of different risk factors for tubeless AID were sourced from the clinical trial. Utilities and cost of diabetes-related complications were obtained from published sources. Treatment costs were derived from US national database sources. Scenario analyses and probabilistic sensitivity analyses were performed to test the robustness of the results. RESULTS: Treating children with T1D with tubeless AID, considering an NSHE threshold of less than 54 mg/dL, brings incremental life-years (1.375) and quality-adjusted life-years (QALYs) (1.521) at an incremental cost of $15,099 compared with SoC, resulting in an incremental cost-effectiveness ratio of $9,927 per QALY gained. Similar results were obtained for adults with T1D assuming an NSHE threshold of less than 54 mg/dL (incremental cost-effectiveness ratio = $10,310 per QALY gained). Furthermore, tubeless AID is a dominant treatment option for children and adults with T1D assuming an NSHE threshold of less than 70 mg/dL compared with SoC. The probabilistic sensitivity analyses results showed that compared with SoC, in both children and adults with T1D, tubeless AID was cost-effective in more than 90% of simulations, assuming a willingness-to-pay threshold of $100,000 per QALY gained. The key drivers of the model were the cost of ketoacidosis, duration of treatment effect, threshold of NSHE, and definition of severe hypoglycemia. CONCLUSIONS: The current analyses suggest that the tubeless AID system can be considered a cost-effective treatment compared with SoC in people with T1D from a US payer's perspective. DISCLOSURES: This research was funded by Insulet. Mr Hopley, Ms Boyd, and Mr Swift are full-time Insulet employees and own stock in Insulet Corporation. IQVIA, the employer of Ms Ramos and Dr Lamotte, received consulting fees for this work. Dr Biskupiak is receiving research support and consulting fees from Insulet. Dr Brixner has received consulting fees from Insulet. The University of Utah has received research funding from Insulet. Dr Levy is a consultant with Dexcom and Eli Lilly and has received grant/research support from Insulet, Tandem, Dexcom, and Abbott Diabetes. Dr Forlenza conducted research sponsored by Medtronic, Dexcom, Abbott, Tandem, Insulet, Beta Bionics, and Lilly. He has been speaker/consultant/advisory board member for Medtronic, Dexcom, Abbott, Tandem, Insulet, Beta Bionics, and Lilly.
Assuntos
Diabetes Mellitus Tipo 1 , Hipoglicemia , Masculino , Adulto , Criança , Humanos , Estados Unidos , Diabetes Mellitus Tipo 1/tratamento farmacológico , Análise Custo-Benefício , Padrão de Cuidado , Insulina , Hipoglicemia/induzido quimicamente , Anos de Vida Ajustados por Qualidade de VidaRESUMO
Personalised health care is an evolution, moving away from a disease-focused model of care, translating scientific and technological advances into benefits for patients, and placing them at the centre of the patients' health and care. Companion diagnostics emerge as a very specific and special group of in vitro diagnostics among the different technologies shaping the personalised health care spectrum. Companion diagnostics provide highly valuable information, allowing patients, health practitioners and payers to decide with a higher level of certainty on the potential benefits of a treatment or care pathway. Decreasing uncertainty may result in a more efficient selection of treatments and care, targeted at subpopulations that are most likely to benefit. Companion diagnostics account for a minimal portion of the already small expenditure on in vitro diagnostics (far less than 1% of total health care expenditure), and yet they provide the means to limit inefficient use of health care resources while optimising patient outcomes. It is clear that equal access to personalised health care is still an issue across the EU. One of the most common perceived barriers is affordability. The investment in companion diagnostics can provide long-term value for patients and health care systems, shifting resources to areas of need. Health systems do not fully recognise yet the value that companion diagnostics bring to make personalised health care more affordable across the EU. This inhibits patient access to personalised treatments and care, preventing improved outcomes. In many countries, market access frameworks for diagnostic tests are fragmented and not aligned with specific funding and reimbursement mechanisms, discouraging the use of these tests. Emerging evidence shows that patients are missing out on the appropriate tests and treatments while a reduction in the inefficient use of health care resources is not realised. This article outlines some of these market access barriers for companion diagnostics in the EU, including reimbursement challenges specific to some member states (Germany, the UK, and France). Furthermore, proposals addressing barriers and increasing timely patient access to companion diagnostics in the EU are presented.
Assuntos
Tecnologia Biomédica , Acessibilidade aos Serviços de Saúde , Técnicas de Diagnóstico Molecular , Medicina de Precisão/economia , Europa (Continente) , Humanos , Segurança do PacienteRESUMO
OBJECTIVE: To determine whether total hip arthroplasty is associated with lower reoperation rates, mortality, and complications, and better function and quality of life than hemiarthroplasty for displaced fractures of the femoral neck in older patients. DESIGN: Systematic review and meta-analysis of randomised trials, quasirandomised trials, and cohort studies. DATA SOURCES: Medline, Embase, Cochrane register of controlled trials, publishers' databases, and manual search of bibliographies. STUDY SELECTION: Randomised controlled trials, quasirandomised trials, and cohort studies (retrospective and prospective) comparing hemiarthroplasty with total hip arthroplasty for treating displaced femoral neck fractures in patients aged more than 60 years. DATA EXTRACTION: Relative risks, risk differences, and mean differences from each trial, aggregated using random effects models. Analyses were stratified for experimental and non-experimental designs, and two way sensitivity analyses and tests for interaction were done to assess the influence of various criteria of methodological quality on pooled estimates. DATA SYNTHESIS: 3821 references were identified. Of the 202 full papers inspected, 15 were included (four randomised controlled trials, three quasirandomised trials, and eight retrospective cohort studies, totalling 1890 patients). Meta-analysis of 14 studies showed a lower risk of reoperation after total hip arthroplasty compared with hemiarthroplasty (relative risk 0.57, 95% confidence interval 0.34 to 0.96, risk difference 4.4%, 95% confidence interval 0.2% to 8.5%), although this effect was mainly driven by investigations without concealed treatment allocation. Total hip arthroplasty consistently showed better ratings in the Harris hip score (three studies, 246 patients, weighted mean difference 5.4, 95% confidence interval 2.7 to 8.2) after follow-up periods of 12 to 48 months. The standardised mean difference of different scores from five studies was 0.42 (95% confidence interval 0.24 to 0.61), indicating a medium functional advantage of total hip arthroplasty over hemiarthroplasty. Total hip arthroplasty was associated with a slightly higher risk of dislocation (relative risk 1.48, 95% confidence interval 0.89 to 2.46) and general complications (1.14, 0.87 to 1.48). CONCLUSION: Single stage total hip arthroplasty may lead to lower reoperation rates and better functional outcomes compared with hemiarthroplasty in older patients with displaced femoral neck fractures. However, heterogeneity across the available trials and distinct subgroup effects preclude definitive statements and require further research in this area.