Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 22
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
Br J Anaesth ; 129(6): 868-878, 2022 12.
Artigo em Inglês | MEDLINE | ID: mdl-36207192

RESUMO

BACKGROUND: The Minto remifentanil pharmacokinetic/pharmacodynamic (PK/PD) model is used in target-controlled infusion (TCI) devices. The endpoint used to calculate the PD parameters, including the ke0, was the electroencephalogram (EEG), which only changes at high remifentanil concentrations. As the ke0 should adequately predict the time course of drug effects at clinically relevant concentrations, we evaluated the temporal agreement between effect-site concentrations estimated with the Minto model and pressure pain thresholds during conscious sedation. METHODS: We enrolled 100 patients scheduled for gynaecological surgery. The first group (35 subjects) received an effect site targeted remifentanil infusion (target 1.5 ng ml-1); the second group (35 subjects) received the same infusion and a 1 mg bolus of midazolam to evaluate anxiolytic effects; the control group (30 subjects) received a saline infusion. Algometry and vital signs were measured at different time points. RESULTS: The Minto model predicted stable effect-site concentrations within 1.5 min of starting the infusion. Haemodynamic variables stabilised within 5 min, whereas there was a significant increase in pressure pain threshold for up to 15 min in both remifentanil groups. Midazolam had no effect on pressure pain threshold. A PD model based on algometry and Minto PK model was developed. CONCLUSIONS: Our results demonstrate the limitation of the Minto PD model at low target remifentanil concentrations, with a discrepancy in the time course between EEG and pressure pain threshold changes. Clinicians should be aware that the time course of onset of analgesic effects is slower than the estimates of the Minto model. Investigators should consider using algometry data in future opioid PD modelling studies.


Assuntos
Sedação Consciente , Midazolam , Humanos , Remifentanil/farmacologia , Midazolam/farmacologia , Infusões Intravenosas , Analgésicos Opioides/farmacologia
2.
Anesth Analg ; 118(1): 116-24, 2014 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-24247230

RESUMO

BACKGROUND: Previous studies have shown that local anesthetics may induce apoptosis in some cell types. In this study, we investigated the apoptotic effects of local anesthetics in human breast tumor cells. METHODS: Human breast cancer (MCF-7) and mammary epithelial (MCF-10A) cell lines were treated with lidocaine and/or bupivacaine. Cell viability, DNA fragmentation, and annexin V immunofluorescence staining were assessed. The effects on apoptosis-related protein expression were investigated by Western blot analysis. The findings were extended to studies in an in vivo xenograft model. RESULTS: Treatment of breast tumor cells with lidocaine and bupivacaine resulted in inhibition of cell viability via induction of apoptosis. The effects were more prominent in MCF-7 cells than in MCF-10A cells. Treatment with local anesthetics induced caspase 7, 8, 9, and poly ADP-ribose polymerase cleavage. The cleavage of caspase 7 and poly ADP-ribose polymerase induced by local anesthetics were effectively blocked by caspase inhibitors. Furthermore, treatment of MCF-7 xenografts with local anesthetics resulted in higher expression of cleaved caspase 7 and an increase in terminal deoxynucleotidyl transferase dUTP nick-end labeling (TUNEL) staining. CONCLUSION: Lidocaine and bupivacaine induce apoptosis of breast tumor cells at clinically relevant concentrations. Our results reveal previously unrecognized beneficial actions of local anesthetics and call for further studies to assess the oncologic advantages of their use during breast cancer surgery.


Assuntos
Anestésicos Locais/farmacologia , Apoptose/efeitos dos fármacos , Neoplasias da Mama , Anestésicos Locais/uso terapêutico , Animais , Apoptose/fisiologia , Neoplasias da Mama/tratamento farmacológico , Neoplasias da Mama/patologia , Linhagem Celular Transformada , Linhagem Celular Tumoral , Sobrevivência Celular/efeitos dos fármacos , Sobrevivência Celular/fisiologia , Feminino , Humanos , Células MCF-7 , Camundongos Endogâmicos BALB C , Ensaios Antitumorais Modelo de Xenoenxerto/métodos
3.
J Pers Med ; 12(8)2022 Aug 21.
Artigo em Inglês | MEDLINE | ID: mdl-36013292

RESUMO

Anesthesia for patients with mucopolysaccharidoses (MPS) is quite challenging due to vital systemic dysfunction following progressive accumulation of lysosomal glycosaminoglycans. Previous studies focused on perioperative difficult airway management under general anesthesia but rarely depicted the concern of choosing the size of the endotracheal tube (ETT) as well as neuraxial anesthesia. This study aimed to analyze the overall anesthetic management and related complications for a thorough anesthetic strategy. Within the study period from 2002 to 2021, each record of the anesthetic and perioperative quality assurance/improvement system for patients with a diagnosis of MPS at MacKay Memorial Hospital was retrospectively reviewed. A total of 51 individuals with 151 anesthesia for 163 interventions were cohort studied, and there were 136 general anesthesia and 15 neuraxial anesthesia. We found that the most common interventions for MPS patients were otolaryngological surgeries (49.6%). Additionally, a secured airway played a marked preference for the most general anesthesia (87.1%). The incidence of difficult intubation was 12.5%. In view of ETT size, a smaller than estimated size was used in MPS type II, III, IV, and VI patients and also in patients who received intubation with multiple attempts. However, a larger than estimated size of ETT was adopted whilst choosing cuffed ones. For neuraxial anesthesia, two failed spinal anesthesia procedures were converted to general anesthesia and 73 percent of the patients received perioperative sedation. In conclusion, through the individualized anesthetic strategy and build-up of an experienced team for airway management, high-quality anesthesia can be ensured in each patient.

4.
J Cardiothorac Vasc Anesth ; 25(6): 931-6, 2011 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-21616681

RESUMO

OBJECTIVE: The objective of this study was to determine the pharmacokinetics of lidocaine in a 48-hour infusion in patients undergoing cardiac surgery with cardiopulmonary bypass (CPB). DESIGN: A retrospective substudy of a clinical trial assessing the efficacy of intravenous lidocaine for postoperative cognitive decline. SETTING: A university hospital. PARTICIPANTS: Ninety-nine patients undergoing cardiac surgery with CPB. INTERVENTIONS: After the induction of anesthesia, lidocaine was administered as a bolus of 1 mg/kg and followed by a continuous infusion at 4 mg/min for the 1st hour, 2 mg/min for the 2nd hour, and 1 mg/min for the next 46 hours. MEASUREMENTS AND MAIN RESULTS: Blood samples were taken at baseline, the end of CPB, and 24 and 48 hours after CPB for the measurement of the plasma concentration of lidocaine. Lidocaine levels increased significantly over time despite a constant rate of infusion (p < 0.05). The pharmacokinetics of lidocaine was best described by a 2-compartment model, and body weight was found to be a significant factor for the volume of the central compartment and clearance. The final pharmacokinetic parameters were V(1)(L) = 0.0619*weight, V(2)(L) = 187, CL(1) (L/min) = 0.00419*weight, and CL(2) (L/min) = 8.92. CONCLUSIONS: A 2-compartment pharmacokinetic model best describes the plasma concentrations of a 48-hour lidocaine infusion in patients undergoing cardiac surgery with CPB. The inclusion of body weight as a covariate on clearance and central compartment improves the model. Lidocaine infusions should be dosed by body weight and decreased after 24 hours to avoid potential toxicity in long-term infusions.


Assuntos
Anestésicos Locais/administração & dosagem , Anestésicos Locais/farmacocinética , Procedimentos Cirúrgicos Cardíacos , Lidocaína/administração & dosagem , Lidocaína/farmacocinética , Cuidados Pós-Operatórios/métodos , Idoso , Algoritmos , Anestésicos Locais/efeitos adversos , Peso Corporal/fisiologia , Ponte Cardiopulmonar , Feminino , Humanos , Infusões Intravenosas , Lidocaína/efeitos adversos , Masculino , Pessoa de Meia-Idade , Modelos Teóricos , População , Estudos Retrospectivos
5.
Pain Med ; 11(3): 390-4, 2010 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-20447308

RESUMO

BACKGROUND AND OBJECTIVES: Ganglion impar block is an uncommon procedure that has been performed traditional with fluoroscopy. One approach is the trans-sacrococcygeal approach. Sometimes this can be difficult because the sacrococcygeal joint (SCJ) cannot be readily seen on anteroposterior (AP) and lateral fluoroscopy. This technical report describes the feasibility of ultrasound in assisting ganglion impar blocks. METHODS: We performed ganglion impar block using ultrasound as the primary imaging tool, with fluoroscopic confirmation in 15 patients. We used a linear array transducer (5-12 MHz) to obtain sonographic transverse and longitudinal views at the sacral cornua; we identified the first cleft below the sacral hiatus as the SCJ. Then we inserted a 23-gauge (7 cm in length) needle into the SCJ under sonographic guidance. Then we confirmed proper needle depth by lateral fluoroscopy and injection of contrast agent. RESULTS: In all 15 procedures, we accurately located and passed the needle into the patients' SCJs under real time sonographic guidance. CONCLUSIONS: In cases where the cleft cannot be readily seen on AP and lateral fluoroscopy, we have found ultrasound to be of assistance. Ultrasound does not replace fluoroscopy, because lateral fluoroscopy is still required to establish safe depth, and correct site of injection. However, ultrasound can be helpful when fluoroscopy alone is insufficient.


Assuntos
Gânglios Simpáticos/diagnóstico por imagem , Bloqueio Nervoso/métodos , Meios de Contraste/administração & dosagem , Estudos de Viabilidade , Fluoroscopia , Bloqueadores Ganglionares/administração & dosagem , Humanos , Agulhas , Decúbito Ventral , Região Sacrococcígea/diagnóstico por imagem , Ultrassonografia
6.
J Chin Med Assoc ; 82(9): 714-718, 2019 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-31356561

RESUMO

BACKGROUND: Administration of propofol, especially rapid administration, decreases patient cardiac output (CO) to various degrees. CO might influence the buildup of an effective drug level within the neuromuscular junction and affect the onset time of neuromuscular blockers. The present study aimed to investigate the effects of different infusion rates of propofol on patient CO and the onset time of rocuronium. METHODS: A total of 90 patients were randomly assigned to receive propofol (2.5 mg/kg) at an infusion rate of 480 mg/min (group A), 240 mg/min (group B), or 120 mg/min (group C). After the administration of propofol, rocuronium (0.6 mg/kg) was administered to facilitate tracheal intubation. The Finometer monitor was used to obtain the cardiovascular profile during the induction of general anesthesia. Neuromuscular relaxation was monitored by acceleromyography using the ulnar nerve at the wrist surface and electrodes with repeated single twitches. Onset time was defined as the time from the beginning of rocuronium injection until 95% twitch depression. The onset time of rocuronium in the three groups was compared using analysis of variance with the post-hoc Tukey test. A p-value <0.05 was considered statistically significant. RESULTS: After induction, a significant decrease in CO was observed in group A (21.6% ± 4.6%) when compared with the findings in group B (11.6% ± 4.5%) and group C (9.8% ± 4.6%). The onset time of rocuronium was significantly longer in group A (177.7 ± 17.6 seconds) than in group B (121.3 ± 18.3 seconds) and group C (118.3 ± 12.3 seconds). CONCLUSION: Rapid administration of propofol significantly delays the onset time of rocuronium by altering CO as measured with the Finometer monitor.


Assuntos
Anestésicos Intravenosos/administração & dosagem , Propofol/administração & dosagem , Rocurônio/farmacologia , Adulto , Pressão Arterial/efeitos dos fármacos , Débito Cardíaco/efeitos dos fármacos , Feminino , Frequência Cardíaca/efeitos dos fármacos , Humanos , Masculino , Pessoa de Meia-Idade , Fatores de Tempo
7.
Anesth Analg ; 107(5): 1566-72, 2008 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-18931213

RESUMO

BACKGROUND: Age is an important determinant of the pharmacokinetic profile of inhaled anesthetics. The influence of age on the dynamic profile of sevoflurane's effect has not been well described. We performed this study to characterize the influence of age and other covariates on the dynamic relationship between sevoflurane end-tidal concentration (C(ET)) and its effect measured by bispectral index (BIS). METHODS: Fifty patients, aged 3-71 yr, scheduled for minor surgery were prospectively studied. The BIS and sevoflurane C(ET) were continuously measured during the study period. During maintenance of anesthesia and after stable BIS values of 60-65 were obtained, the inspired concentration of sevoflurane was increased to 5 vol % for 5 min or until BIS <40 and then decreased. The dynamic relationship between sevoflurane C(ET) and its effect as measured by BIS during this transition period were modeled with an inhibitory E(max) model using a population pharmacokinetic-pharmacodynamic approach with NONMEM V. A predictive check method was used to validate the final model. RESULTS: The sensitivity to sevoflurane's effect as measured by BIS expressed in the C(50) [steady-state C(ET) eliciting half of maximum response (I(max))] increased with age. The speed of change of sevoflurane's effect, expressed as the effect-site equilibration half-life (t(1/2) k(e0)), increased at older ages. The predictive check analysis confirmed the adequacy of the model. CONCLUSIONS: Age significantly affects the dynamic relationship between sevoflurane C(ET) and its effect measured with BIS.


Assuntos
Envelhecimento/fisiologia , Anestésicos Inalatórios/farmacologia , Éteres Metílicos/farmacologia , Volume de Ventilação Pulmonar , Adolescente , Adulto , Idoso , Envelhecimento/efeitos dos fármacos , Criança , Pré-Escolar , Hipersensibilidade a Drogas , Eletroencefalografia/efeitos dos fármacos , Humanos , Pessoa de Meia-Idade , Sevoflurano , Volume de Ventilação Pulmonar/efeitos dos fármacos
8.
Anesth Analg ; 106(1): 109-13, table of contents, 2008 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-18165563

RESUMO

BACKGROUND: Mirtazapine is a new antidepressant that blocks 5-HT2 and 5-HT3 receptors. With this receptor profile, it is possible that mirtazapine could provide both anxiolysis and efficacy for postoperative nausea and vomiting (PONV). We therefore tested the hypothesis that premedication with mirtazapine can reduce preoperative anxiety and PONV. METHODS: Eighty female patients with at least two PONV risk factors scheduled for gynecological surgery were enrolled. Dexamethasone 8 mg was given before induction of anesthesia and patients were randomly assigned to group M + D (mirtazapine plus dexamethasone) or group dexamethasone. An oral disintegrating mirtazapine 30 mg or placebo tablet was given 1 h before surgery. Preoperative anxiety level was assessed by a visual analog scale (VAS) before mirtazapine administration and 1 h thereafter. General anesthesia was induced with 1% propofol at the rate of 200 mL/h (until loss of consciousness) and was then maintained with sevoflurane in oxygen and air. An auditory evoked potentials index monitor was used to titrate sevoflurane. The incidence of PONV, the use of rescue antiemetic, complete response, postoperative Ramsay Sedation Scores, and VAS pain scores were assessed 1, 2, and 24 h after surgery and compared. RESULTS: The VAS anxiety scale was lower in group M + D after mirtazapine administration. There were no differences in the induction dose of propofol, the concentrations of sevoflurane during anesthesia, and recovery times between the two groups. The incidence of complete response to PONV over 0-24 h was lower in group M + D (80% vs 50%, P < 0.01). CONCLUSIONS: Premedication with mirtazapine 30 mg reduces the level of preoperative anxiety and the risk of PONV in moderate and high-risk female patients.


Assuntos
Ansiolíticos/uso terapêutico , Antieméticos/uso terapêutico , Ansiedade/prevenção & controle , Procedimentos Cirúrgicos em Ginecologia , Mianserina/análogos & derivados , Náusea e Vômito Pós-Operatórios/prevenção & controle , Medicação Pré-Anestésica , Antagonistas da Serotonina/uso terapêutico , Adulto , Analgésicos Opioides/uso terapêutico , Ansiolíticos/efeitos adversos , Antieméticos/efeitos adversos , Método Duplo-Cego , Feminino , Humanos , Mianserina/efeitos adversos , Mianserina/uso terapêutico , Pessoa de Meia-Idade , Mirtazapina , Morfina/uso terapêutico , Medição da Dor , Dor Pós-Operatória/prevenção & controle , Antagonistas da Serotonina/efeitos adversos , Fatores de Tempo , Resultado do Tratamento
9.
Taiwan J Obstet Gynecol ; 55(6): 810-814, 2016 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-28040125

RESUMO

OBJECTIVE: Lumbosacral cerebrospinal fluid volume is decreased as the enlarging uterus compresses the inferior vena cava during pregnancy. A subsequent greater cephalad spread of sensory blockade is observed. Gravid uterus plays a crucial role in affecting the spinal anesthesia level. We hypothesized that maternal abdominal circumference can reflect compressive effect of the uterus and investigated the relationship between abdominal circumference and the level of sensory blockade, and incidence of hypotension following spinal anesthesia with hyperbaric bupivacaine in term parturients. MATERIALS AND METHODS: Forty-two term parturients scheduled for elective cesarean section were studied. Abdominal circumference was measured before spinal anesthesia; 0.5% hyperbaric bupivacaine (2 mL, 2.2 mL, or 2.4 mL) was injected in to the subarachnoid space at the L3-L4 intervertebral level according to the parturient's height. The level of sensory blockade was assessed using an ice cube 1 minute, 5 minutes, 10 minutes, and 15 minutes after the spinal injection. The level of sensory blockade at the 15th minute was defined as the level of maximum sensory blockade. Statistical correlation coefficients were evaluated with Spearman's rank correlation. RESULTS: The correlation coefficient between the abdominal circumference and spinal level measured by cold sensation loss at 5 minutes after spinal anesthesia was significantly positive (right side ρ=0.43, p=0.005; left side ρ=0.46, p=0.003). No significant correlation was found between abdominal circumference and the level of maximum sensory blockade, the incidence of hypotension, ephedrine dosage, nausea, and vomiting after spinal anesthesia. CONCLUSION: Parturients with greater abdominal circumference value have a higher level of sensory blockade at 5 minutes after spinal anesthesia. Abdominal circumference cannot predict the maximum sensory blockade level and the incidence of hypotension.


Assuntos
Anestesia Obstétrica/métodos , Raquianestesia/métodos , Anestésicos Locais/administração & dosagem , Bupivacaína/administração & dosagem , Cesárea , Circunferência da Cintura , Administração Intravenosa , Adulto , Feminino , Humanos , Gravidez , Cuidados Pré-Operatórios , Fatores de Tempo
10.
J Clin Anesth ; 17(5): 353-7, 2005 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-16102685

RESUMO

STUDY OBJECTIVE: To investigate the difference of regional cerebral oxygen saturation (rSo2) decrease in response to the decrease in mean arterial blood pressure (MAP) in young and elderly patients. DESIGN: Prospective clinical study. SETTING: Medical center hospital. PATIENTS: Twenty-four American Society of Anesthesiologists physical status I and II patients, 12 of whom were young and the other 12 elderly, scheduled for elective surgery requiring general anesthesia. Patients received propofol 2 mg/kg (young patient group) and propofol 1.5 mg/kg (elderly patient group) as an induction drug. MEASUREMENTS: MAP and rSo2 were recorded continuously for 5 minutes after propofol administration. MAIN RESULTS: MAP values at the second to fifth minutes and rSo2 at the second minute after propofol administration were significantly lower than baseline in both groups (P<.05). The rSo2 decrease was minimal, and the slopes of the rSo2 decrease in response to the MAP decrease in the young and elderly groups were 0.093+/-0.012 (P<.001) and 0.112+/-0.016 (P<.001) (mean+/-SEM), respectively. CONCLUSIONS: After propofol induction, there was no difference between young and elderly patients in rSo2 decrease in response to the decrease in MAP.


Assuntos
Anestésicos Intravenosos/farmacologia , Pressão Sanguínea/efeitos dos fármacos , Encéfalo/metabolismo , Oxigênio/metabolismo , Propofol/farmacologia , Adulto , Fatores Etários , Idoso , Idoso de 80 Anos ou mais , Circulação Cerebrovascular , Feminino , Humanos , Masculino , Estudos Prospectivos
11.
Acta Anaesthesiol Sin ; 40(3): 109-16, 2002 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-12434606

RESUMO

BACKGROUND: Hemorrhagic shock upregulates inducible nitric oxide (NO) synthase (iNOS) expression and the resultant NO overproduction. Liver is one of the major organs that is responsible for increased NO production after trauma-hemorrhage and resuscitation. Guanosine triphosphate cyclohydrolase I (GTPCH) is the rate-limiting enzyme for the synthesis of tetrahydrobiopterin (BH4), a necessary co-factor for iNOS activity. Very little is known about the effects of hemorrhagic shock on hepatic GTPCH expression. METHODS: Fifteen male Sprague-Dawley rats were randomly assigned to one of three groups, i.e. a sham instrumented (Sham) group, a sustained hemorrhagic shock (HS) group, and a hemorrhagic shock with resuscitation (HS/RES) group (n = 5 in each group). Controlled hemorrhagic shock was induced and the mean arterial pressure (MAP) was kept between 40-45 mmHg for sixty minutes in both HS and HS/RES groups. Then resuscitation with infusion of shed autologous blood and normal saline was performed in HS/RES group. Microdialysis probes were put in the liver and the right atrium for collection of serial samples. NO concentrations in dialysate samples were measured using chemiluminescence. Hepatic iNOS and GTPCH mRNA concentrations were analyzed using semiquantitative reverse transcription and polymerase chain reaction (RT-PCR). RESULTS: Hemorrhagic shock induced both the hepatic and circulating NO biosynthesis as well as hepatic iNOS mRNA expression. Resuscitation with shed blood/normal saline normalized this upregulation. However, no difference was found in mean hepatic GTPCH mRNA concentrations between groups in this experiment. CONCLUSIONS: We provide the evidence that hemorrhagic shock-induced NO biosynthesis involves upregulation of iNOS transcription in liver tissue and GTPCH transcription is unaffected by either hemorrhagic shock or resuscitation. Furthermore, microdialysis is an ideal technique for serial sampling and that events can be followed.


Assuntos
GTP Cicloidrolase/genética , Fígado/metabolismo , Óxido Nítrico/biossíntese , RNA Mensageiro/análise , Choque Hemorrágico/metabolismo , Animais , Masculino , Microdiálise , Óxido Nítrico Sintase/biossíntese , Óxido Nítrico Sintase/genética , Óxido Nítrico Sintase Tipo II , Ratos , Ratos Sprague-Dawley , Análise de Regressão , Reação em Cadeia da Polimerase Via Transcriptase Reversa
12.
Acta Anaesthesiol Sin ; 40(3): 127-33, 2002 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-12434609

RESUMO

BACKGROUND: Bolus thermodilution cardiac output (BCO) measurement has been considered as the "gold standard" for cardiac output (CO) measurement. However, it requires placement of a pulmonary artery (PA) catheter, and questions have been raised regarding the risk/benefit ratio of this invasive technique. Furthermore, great variations between measurements have been reported. Continuous thermodilution CO (CCO) measurement is reported to be a better alternative, but it still requires the placement of a PA catheter. Esophageal echo-Doppler ultrasonography (ED) provides non-invasive continuous measurement of CO (ED-CO). This study was thus designed to compare the agreement between ED-CO and both thermodilution techniques (BCO and CCO). METHODS: Twenty-four patients undergoing primary coronary artery bypass graft surgery were randomized to have a PA catheter placed for measurement of either BCO or CCO. All patients also had an ED probe placed. In Group I patients (n = 12), BCO measurement was carried out every 15 minutes throughout the surgery except during cardiopulmonary bypass, with concurrent ED-CO reading recorded at the same time point. In Group II patients (n = 12), CCO and ED-CO measurements were recorded at the same designated points of time as in Group I. The agreement between methods (BCO vs. ED-CO or CCO vs. ED-CO) was assessed using Bland-Altman method. RESULTS: The range of measured CO of each method was 2.1 to 9.4 l/min for BCO, 2.4 to 9.2 l/min for CCO and 2.3 to 8.9 l/min for ED-CO. ED-CO and CCO had excellent agreement with a linear regression coefficient (r2 value) of 0.846, and a bias (mean difference) and SD of bias of 0.05 +/- 0.49 l/min. In contrast, the agreement between BCO and ED-CO was poorer; correlation was low (r2 value 0.406) and both the bias and SD of bias were high (0.11 +/- 1.12 l/min). Furthermore, BCO measurements had poor reproducibility, whereas both ED-CO and CCO measurements had good reproducibility. CONCLUSIONS: Esophageal echo-Doppler ultrasonography is a satisfactory alternative for cardiac output measurement because it gives a value in good agreement with CCO measurement. With significant between-measurement variations, the accuracy and precision of BCO are uncertain, and it should not be considered as the "gold standard".


Assuntos
Débito Cardíaco , Cateterismo de Swan-Ganz , Ponte de Artéria Coronária , Ecocardiografia Doppler , Ecocardiografia Transesofagiana , Adulto , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Reprodutibilidade dos Testes
14.
Acta Anaesthesiol Taiwan ; 47(3): 143-6, 2009 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-19762306

RESUMO

Methemoglobinemia occasionally causes cyanosis particularly in congenital methemoglobinemia. Avoidance of exposure to oxidizing agents is important for patients with congenital methemoglobinemia because of their deficient enzymatic pathways and decreased oxygen-carrying capacity. Here, we present a patient with preoperatively undiagnosed congenital methemoglobinemia who underwent uterine myomectomy under general anesthesia. The patient was a 35-year-old woman who displayed a low pulse oximetry reading of 91% prior to induction of anesthesia. Methemoglobinemia was first suspected intraoperatively because of a mismatch of SpO2 of finger pulse oximetry and SaO2 of arterial blood, and was later confirmed by multiple-wavelength CO-oximetry. The pathophysiology, etiology, clinical manifestations, anesthetic considerations, and treatment options of methemoglobinemia are discussed.


Assuntos
Anestesia/métodos , Metemoglobinemia/congênito , Adulto , Feminino , Humanos , Metemoglobinemia/terapia , Azul de Metileno/uso terapêutico , Oxigênio/sangue
15.
Acta Anaesthesiol Taiwan ; 45(3): 141-7, 2007 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-17972616

RESUMO

BACKGROUND: The performance of target-controlled infusion (TCI) devices is important for the safety of patients. This study examined the performance of two propofol pharmacokinetic parameter sets in Chinese patients by computer simulation. METHODS: Two sets of propofol pharmacokinetic parameters respectively derived from Marsh's and Schnider's studies were compared with those obtained in Chinese subjects from Li's study. Pharmacokinetic parameters of propofol from Li's study for subjects of three different entities (average adult, obese adult, and elderly) were used to estimate the performance of Marsh's and Schnider's models. Sixty virtual patients were generated with Li's parameters. A computer program, STANPUMP, was used to perform the pharmacokinetic simulation. An induction dose of propofol at 2 mg/kg for average or obese adult, while 1.5 mg/kg for the elderly, followed by TCI of 4 microg/mL (average and obese adult) or 3 microg/mL (elderly) were simulated. The infusion schemes generated by STANPUMP using Marsh's or Schnider's model were put in to simulate the predicted plasma concentration based on the pharmacokinetic parameters from Li's study. The median performance error (MDPE) and absolute median performance error (MDAPE) were calculated to estimate the bias and inaccuracy. Differences between models were calculated using the paired t test. A P value < 0.05 was considered statistically significant. RESULTS: The bias and inaccuracy by Marsh's model in average adults were -11.9% and 18.5% respectively and by Schnider's model were -8.6% and 17.9%. For obese adults, the bias and inaccuracy were 6.3% and 26.2% respectively for Marsh's model and -6.6% and 22.6% for Schnider's model. Sohnider's model resulted in a significantly greater inaccuracy than Marsh's model (42.1% versus 15.5%) when applied to elderly patients. CONCLUSIONS: The performance of TCI infusion of propofol in Chinese patients is generally acceptable with Marsh's or Schnider's model apart from using Schnider's model in Chinese elderly patients. Further study to investigate the difference of propofol pharmacokinetics between Chinese and non-Chinese elderly patients is necessary.


Assuntos
Anestesia Intravenosa/instrumentação , Anestésicos Intravenosos/administração & dosagem , Simulação por Computador , Bombas de Infusão , Propofol/administração & dosagem , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Criança , Pré-Escolar , Humanos , Lactente , Pessoa de Meia-Idade , Propofol/farmacocinética
16.
Acta Anaesthesiol Taiwan ; 45(1): 43-6, 2007 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-17424759

RESUMO

Postoperative respiratory failure caused by Guillain-Barré syndrome (GBS) is a rare complication after general anesthesia. We report a GBS patient who after receiving an operation for polycystic liver disease under general anesthesia developed weakness of upper and lower extremities on the 3rd postoperative day, with decreased deep tendon reflex, which ultimately evolved into respiratory failure. Slurred speech and bilateral ptosis were also noted. All these manifested an acute peripheral polyneuropathy combined with bulbar involvement. According to the clinical picture, CSF examination and results of nerve conduction tests, Guillain-Barré syndrome was diagnosed. Plasmapheresis was immediately arranged and her motor weakness problem was soon improved after treatment. No neurological sequelae were found two months after discharge. Postoperative muscle weakness is usually caused by residual effects of anesthetic agents or surgical complications. But it may sometimes be related to some rare neurological diseases. To prompt an accurate diagnosis of Guillain-Barré syndrome is important because it can help forestall fatal complications. In addition, the prognosis will be encouraging with early treatment.


Assuntos
Síndrome de Guillain-Barré/complicações , Complicações Pós-Operatórias/etiologia , Insuficiência Respiratória/etiologia , Feminino , Síndrome de Guillain-Barré/terapia , Humanos , Imunoglobulinas Intravenosas/uso terapêutico , Pessoa de Meia-Idade
17.
Acta Anaesthesiol Taiwan ; 45(3): 155-62, 2007 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-17972618

RESUMO

BACKGROUND: During spinal anesthesia, hemodynamic status is routinely monitored, but this may not give an accurate assessment of cerebral oxygenation. Cerebral oximetry, facilitated by using a near-infrared spectroscope, is a way of estimating regional cerebral oxygen saturation (SrO2). We designed this prospective clinical study to determine whether the changes in mean arterial pressure (MAP) and heart rate (HR) could predict changes in SrO2 during spinal anesthesia. METHODS: The study sample available for analysis included 45 patients, ASA class I to II, who were scheduled for elective ureteroscopic surgery requiring spinal anesthesia. Spinal anesthesia was performed with 12 mg 0.5% hyperbaric bupivacaine injected intrathecally via L3-4 or L4-5 interspace. MAP, HR, oxygen saturation by pulse oximeter, and SrO2 by near-infrared spectroscope were recorded every 2 min throughout the procedure. RESULTS: SrO2 was tested by the Shapiro-Wilk test and the results departed from the multivariate normal distribution. The method of generalized estimating equations (GEE) was then used to estimate the model. The output of the GEE analysis for the time-lag model showed that there were relationships between SrO2 and two predictors (MAP and HR) with the correction of the baseline values. All the parameters were significant at a level of 5%. The effects of the decreases of MAP and HR on SrO2 lasted continuously for at least 6 min. CONCLUSIONS: Based on the time-lag pattern between two predictors (MAP and HR) and SrO2 during spinal anesthesia, we ventured to conclude that a change in MAP or HR caused a significant decrease in SrO2. Since no patient developed any neurologic complication perioperatively, further study must be performed to elucidate the clinical importance of our findings.


Assuntos
Raquianestesia , Encéfalo/metabolismo , Oxigênio/metabolismo , Adulto , Idoso , Pressão Sanguínea , Feminino , Frequência Cardíaca , Humanos , Masculino , Pessoa de Meia-Idade , Oximetria , Estudos Prospectivos
18.
Anesthesiology ; 103(3): 613-8, 2005 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-16129988

RESUMO

BACKGROUND: The goal of this study was to evaluate whether preoperative pressure pain sensitivity testing is predictive of postoperative surgical pain. METHODS: Female subjects undergoing lower abdominal gynecologic surgery were studied. A pressure algometer was used preoperatively to determine the pressure pain threshold and tolerance. A visual analog scale (VAS) was used to assess postoperative pain. A State-Trait Anxiety Inventory was used to assess patients' anxiety. Subjects received intravenous patient-controlled analgesia for postoperative pain control. The preoperative pain threshold and tolerance were compared with the postoperative VAS pain score and morphine consumption. RESULTS: Forty women were enrolled. Their preoperative pressure pain threshold and tolerance were 141 +/- 65 kPa and 223 +/- 62 kPa, respectively. The VAS pain score in the postanesthesia care unit and at 24 h postoperatively were 81 +/- 24 and 31 +/- 10, respectively. Highly anxious patients had higher VAS pain scores in the postanesthesia care unit (P < 0.05). Pressure pain tolerance was significantly correlated with the VAS at 24 h postoperatively (P < 0.001, r = -0.52). Pressure pain tolerance after fentanyl administration (mean, 272 +/- 68 kPa) correlated significantly with morphine consumption in the first 24 h postoperatively (P < 0.002, r = -0.48). CONCLUSIONS: Assessment of preoperative pressure pain tolerance is significantly correlated with the level of postoperative pain. Pain tolerance assessment after fentanyl was administered and fentanyl sensitivity predicted the dose of analgesics used in the first 24 h after surgery. The algometer is thus a simple, useful tool for predicting postoperative pain and analgesic consumption.


Assuntos
Medição da Dor , Limiar da Dor , Dor Pós-Operatória/fisiopatologia , Adulto , Analgesia Controlada pelo Paciente , Ansiedade/fisiopatologia , Humanos , Pessoa de Meia-Idade , Morfina/administração & dosagem , Pressão
19.
Can J Anaesth ; 52(4): 374-8, 2005 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-15814751

RESUMO

PURPOSE: Excessive blood sampling, with its inherent risks, is of growing concern among clinicians. We performed this study to measure the changes in hematocrit (Hct) during a laboratory investigation where multiple blood samples are collected. The performance of a simple mathematical model, used in clinical practice to predict Hct changes, is evaluated. METHODS: Eight healthy male volunteers participated in this study. The equation Hct(f) = Hct(i)*(EBV-BL)/EBV is used to predict changes in Hct. Where Hct(f) and Hct(i) are, respectively, the final and initial Hct, EBV is the estimated blood volume and BL is the blood loss. RESULTS: Thirty-five pharmacokinetic samples per subject were collected totalling 314 mL of BL. The Hct decreased from 44.2% +/- 2.2% to 39.9% +/- 2.5% (P = 0.001). On average, model predictions tended to have a discrete tendency to underestimate the Hct changes (-0.5% points of bias). While the predictions of the Hct were very accurate in 50% of the subjects, the discrepancy of the Hct predictions was clinically significant in the other 50% of the subjects. CONCLUSION: Consistent with the model prediction, this study demonstrated a significant reduction in the Hct values in healthy subjects undergoing incremental phlebotomy. On average, the model successfully predicted the decrease in Hct. However, the inter- and intra-individual variabilities in the Hct changes are clinically significant. In clinical settings, which are not well controlled environments, the variability is likely to be greater and the clinical use of the model cannot replace the need to monitor the Hct.


Assuntos
Hematócrito , Flebotomia/efeitos adversos , Adulto , Humanos , Masculino , Matemática , Modelos Teóricos
20.
Anesthesiology ; 101(5): 1066-76, 2004 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-15505441

RESUMO

BACKGROUND: Dexmedetomidine, a highly selective alpha2-adrenoceptor agonist used for short-term sedation of mechanically ventilated patients, has minimal effect on ventilation. METHODS: This study compared the respiratory effect of dexmedetomidine to that of remifentanil. The authors measured and compared respiratory responses of six healthy male volunteers during (1) a stepwise target-controlled infusion of remifentanil, (2) a stepwise target-controlled infusion of dexmedetomidine, and (3) a pseudonatural sleep session. RESULTS: Compared with baseline, remifentanil infusions resulted in respiratory depression as evidenced by a decrease in respiratory rate and minute ventilation, respiratory acidosis, and apnea episodes resulting in desaturations. Remifentanil disturbed the natural pattern of breathing and flattened the distribution of ventilatory timing (inspiratory time/ventilatory cycle time). The respiratory effects of dexmedetomidine markedly contrasted with those of remifentanil. When compared with baseline, during dexmedetomidine infusions, the respiratory rate significantly increased, and the overall apnea/hypopnea index significantly decreased. The distribution of inspiratory time/ventilatory cycle time showed an increased peak. In addition, dexmedetomidine seemed to mimic some aspect of natural sleep. While the subjects were breathing a 5% CO2 mixture, hypercapnic arousal phenomena (documented by the Bispectral Index, the electroencephalogram, and sudden increase in the minute ventilation) were observed during dexmedetomidine infusions. Similar phenomena during natural sleep have been reported in the literature. CONCLUSIONS: In comparison with remifentanil, dexmedetomidine infusions (1) did not result in clinically significant respiratory depression, (2) decreased rather than increased the apnea/hypopnea index, and (3) exhibited some similarity with natural sleep.


Assuntos
Analgésicos Opioides/efeitos adversos , Dexmedetomidina/efeitos adversos , Hipnóticos e Sedativos/efeitos adversos , Piperidinas/efeitos adversos , Mecânica Respiratória/efeitos dos fármacos , Adulto , Algoritmos , Analgésicos Opioides/farmacocinética , Calibragem , Dióxido de Carbono/sangue , Estudos Cross-Over , Dexmedetomidina/farmacocinética , Eletroencefalografia/efeitos dos fármacos , Hemodinâmica/efeitos dos fármacos , Humanos , Hipercapnia/metabolismo , Hipnóticos e Sedativos/farmacocinética , Infusões Intravenosas , Masculino , Oxigênio/sangue , Piperidinas/farmacocinética , Remifentanil , Sono/efeitos dos fármacos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA