Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 42
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
J Comput Assist Tomogr ; 48(1): 1-11, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-37574655

RESUMO

ABSTRACT: The Fontan procedure is the definitive treatment for patients with single-ventricle physiology. Surgical advances have led to a growing number of patients surviving into adulthood. Fontan-associated liver disease (FALD) encompasses a spectrum of pathologic liver changes that occur secondary to altered physiology including congestion, fibrosis, and the development of liver masses. Assessment of FALD is difficult and relies on using imaging alongside of clinical, laboratory, and pathology information. Ultrasound, computed tomography, and magnetic resonance imaging are capable of demonstrating physiologic and hepatic parenchymal abnormalities commonly seen in FALD. Several novel imaging techniques including magnetic resonance elastography are under study for use as biomarkers for FALD progression. Imaging has a central role in detection and characterization of liver masses as benign or malignant. Benign FNH-like masses are commonly encountered; however, these can display atypical features and be mistaken for hepatocellular carcinoma (HCC). Fontan patients are at elevated risk for HCC, which is a feared complication and has a poor prognosis in this population. While imaging screening for HCC is widely advocated, no consensus has been reached regarding an optimal surveillance regimen.


Assuntos
Carcinoma Hepatocelular , Hepatopatias , Neoplasias Hepáticas , Humanos , Carcinoma Hepatocelular/patologia , Neoplasias Hepáticas/diagnóstico por imagem , Neoplasias Hepáticas/cirurgia , Hepatopatias/diagnóstico por imagem , Fígado/diagnóstico por imagem , Ultrassonografia , Fibrose , Cirrose Hepática
2.
Pediatr Radiol ; 53(6): 1049-1056, 2023 05.
Artigo em Inglês | MEDLINE | ID: mdl-36596868

RESUMO

BACKGROUND: The Brody II score uses chest CT to guide therapeutic changes in children with cystic fibrosis; however, patients and providers are often reticent to undergo chest CT given concerns about radiation. OBJECTIVE: We sought to determine the ability of a reduced-dose photon-counting detector (PCD) chest CT protocol to reproducibly display pulmonary disease severity using the Brody II score for children with cystic fibrosis (CF) scanned at radiation doses similar to those of a chest radiograph. MATERIALS AND METHODS: Pediatric patients with CF underwent non-contrast reduced-dose chest PCD-CT. Volumetric inspiratory and expiratory scans were obtained without sedation or anesthesia. Three pediatric radiologists with Certificates of Added Qualification scored each scan on an ordinal scale and assigned a Brody II score to grade bronchiectasis, peribronchial thickening, parenchymal opacity, air trapping and mucus plugging. We report image-quality metrics using descriptive statistics. To calculate inter-rater agreement for Brody II scoring, we used the Krippendorff alpha and intraclass correlation coefficient (ICC). RESULTS: Fifteen children with CF underwent reduced-dose PCD chest CT in both inspiration and expiration (mean age 8.9 years, range, 2.5-17.5 years; 4 girls). Mean volumetric CT dose index (CTDIvol) was 0.07 ± 0.03 mGy per scan. Mean effective dose was 0.12 ± 0.04 mSv for the total examination. All three readers graded spatial resolution and noise as interpretable on lung windows. The average Brody II score was 12.5 (range 4-19), with moderate inter-reader reliability (ICC of 0.61 [95% CI=0.27, 0.84]). Inter-rater reliability was moderate to substantial for bronchiectasis (0.52), peribronchial thickening (0.55), presence of opacity (0.62) and air trapping (0.70) and poor for mucus plugging (0.09). CONCLUSION: Reduced-dose PCD-CT permits diagnostic image quality and reproducible identification of Brody II scoring imaging findings at radiation doses similar to those for chest radiography.


Assuntos
Bronquiectasia , Fibrose Cística , Feminino , Humanos , Criança , Fibrose Cística/diagnóstico por imagem , Projetos Piloto , Reprodutibilidade dos Testes , Tomografia Computadorizada por Raios X/métodos , Pulmão , Doses de Radiação
3.
Am J Hum Genet ; 105(1): 108-121, 2019 07 03.
Artigo em Inglês | MEDLINE | ID: mdl-31204009

RESUMO

Pediatric acute liver failure (ALF) is life threatening with genetic, immunologic, and environmental etiologies. Approximately half of all cases remain unexplained. Recurrent ALF (RALF) in infants describes repeated episodes of severe liver injury with recovery of hepatic function between crises. We describe bi-allelic RINT1 alterations as the cause of a multisystem disorder including RALF and skeletal abnormalities. Three unrelated individuals with RALF onset ≤3 years of age have splice alterations at the same position (c.1333+1G>A or G>T) in trans with a missense (p.Ala368Thr or p.Leu370Pro) or in-frame deletion (p.Val618_Lys619del) in RINT1. ALF episodes are concomitant with fever/infection and not all individuals have complete normalization of liver function testing between episodes. Liver biopsies revealed nonspecific liver damage including fibrosis, steatosis, or mild increases in Kupffer cells. Skeletal imaging revealed abnormalities affecting the vertebrae and pelvis. Dermal fibroblasts showed splice-variant mediated skipping of exon 9 leading to an out-of-frame product and nonsense-mediated transcript decay. Fibroblasts also revealed decreased RINT1 protein, abnormal Golgi morphology, and impaired autophagic flux compared to control. RINT1 interacts with NBAS, recently implicated in RALF, and UVRAG, to facilitate Golgi-to-ER retrograde vesicle transport. During nutrient depletion or infection, Golgi-to-ER transport is suppressed and autophagy is promoted through UVRAG regulation by mTOR. Aberrant autophagy has been associated with the development of similar skeletal abnormalities and also with liver disease, suggesting that disruption of these RINT1 functions may explain the liver and skeletal findings. Clarifying the pathomechanism underlying this gene-disease relationship may inform therapeutic opportunities.


Assuntos
Autofagia , Doenças do Desenvolvimento Ósseo/etiologia , Proteínas de Ciclo Celular/genética , Fibroblastos/patologia , Falência Hepática Aguda/etiologia , Mutação , Idade de Início , Alelos , Sequência de Aminoácidos , Doenças do Desenvolvimento Ósseo/metabolismo , Doenças do Desenvolvimento Ósseo/patologia , Proteínas de Ciclo Celular/metabolismo , Criança , Pré-Escolar , Feminino , Fibroblastos/metabolismo , Complexo de Golgi/metabolismo , Complexo de Golgi/patologia , Humanos , Lactente , Falência Hepática Aguda/metabolismo , Falência Hepática Aguda/patologia , Masculino , Linhagem , Transporte Proteico , Recidiva , Homologia de Sequência
4.
Pediatr Radiol ; 52(10): 1877-1887, 2022 09.
Artigo em Inglês | MEDLINE | ID: mdl-35364682

RESUMO

Chest CT in pediatric patients on extracorporeal membrane oxygenation (ECMO) can be done safely and provide valuable high-quality diagnostic images to help guide patient management. An understanding of the basics of the ECMO circuit, cannula locations, where and how to inject contrast media, and how to time image acquisition is vital for the radiologist. Additionally, understanding the precautions associated with performing these exams is essential to ensure the safety of the child. This article provides a brief review of pediatric ECMO and its challenges and considerations, as well as a stepwise approach to perform and optimize these exams safely.


Assuntos
Oxigenação por Membrana Extracorpórea , Criança , Meios de Contraste , Humanos , Tomografia Computadorizada por Raios X/métodos
5.
Pediatr Radiol ; 52(12): 2254-2266, 2022 11.
Artigo em Inglês | MEDLINE | ID: mdl-36207454

RESUMO

Although rare, pediatric peritoneal carcinomatosis does occur in primary abdominopelvic tumors. Additionally, peritoneal carcinomatosis has been described to occur as metastatic disease where the primary tumor is outside the abdominopelvic cavity. Where amenable, cytoreductive surgery and hyperthermic intraperitoneal chemotherapy (HIPEC) can be beneficial in disease management. However, favorable outcomes are predicated on specific tumor histology as well as proper patient selection, which significantly relies on preoperative imaging. This review gives a comprehensive, up-to-date summary on pediatric peritoneal carcinomatosis pre-surgical evaluation; where imaging is beneficial and limited; pediatric radiologists' role in helping to quantify disease; and how we, as pediatric radiologists, can help the surgeons and oncologists in the selection of patients for cytoreductive surgery and HIPEC.


Assuntos
Hipertermia Induzida , Neoplasias Peritoneais , Humanos , Criança , Procedimentos Cirúrgicos de Citorredução/métodos , Neoplasias Peritoneais/terapia , Neoplasias Peritoneais/tratamento farmacológico , Quimioterapia Intraperitoneal Hipertérmica , Hipertermia Induzida/métodos , Terapia Combinada
6.
Pediatr Radiol ; 51(13): 2481-2491, 2021 12.
Artigo em Inglês | MEDLINE | ID: mdl-34490496

RESUMO

BACKGROUND: Children with perianal fistulizing Crohn disease require intensive medical management but also have a higher risk for subsequent surgical interventions. OBJECTIVE: We performed a retrospective study to identify patient factors and perianal anatomical features by pelvic MR that are associated with surgical interventions in these children. MATERIALS AND METHODS: We included children with Crohn disease and perianal fistula who underwent pelvic MR with available, archived images and collected demographic, clinical and laboratory data. Radiologists reviewed pelvic MR exams and identified Park classification and additional anatomical features of perianal fistulas, including fistula branching, horseshoe ramifications, abscess, inflammatory mass, supralevator extension, anal sphincter damage, proctitis and posterior anal space involvement. We performed univariate and subsequent multivariate analysis to determine features associated with subsequent surgical intervention. RESULTS: Ninety-nine children with Crohn disease underwent pelvic MR. In this cohort, 69 children had no surgical interventions prior to baseline MRI, with subsequent median clinical follow-up of 5.5 years. Univariate analysis demonstrated that branching (P=0.009), supralevator extension (P=0.015) and anal sphincter damage (P=0.031) were significantly associated with subsequent surgical intervention. Age at baseline MRI was also associated with intervention (hazard ratio [HR] every 5 years: 2.13; 95% confidence interval [CI]: 1.18-3.83; P=0.012). A multivariable model identified only fistula branching (HR: 2.31; 95% CI: 1.28-4.15; P=0.005) and age (HR: 5.18; CI: 1.57-17.14; P=0.007) as independent predictors of subsequent surgery. No demographic, clinical or laboratory parameter predicted subsequent surgical intervention. CONCLUSION: Age and anatomical MR features indicating fistula complexity (branching, supralevator extension) and sphincter damage confer a higher risk of subsequent surgical intervention in children with perianal Crohn disease.


Assuntos
Doença de Crohn , Fístula Retal , Canal Anal , Criança , Doença de Crohn/complicações , Doença de Crohn/diagnóstico por imagem , Humanos , Imageamento por Ressonância Magnética , Fístula Retal/diagnóstico por imagem , Estudos Retrospectivos
7.
J Appl Clin Med Phys ; 22(2): 194-202, 2021 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-33338314

RESUMO

It is important to employ radiation dose reduction techniques in pediatric computed tomography (CT) to reduce potential risks of radiation-induced malignancy. Automatic tube potential (kV) selection tools have been developed and become available on many CT scanners, which select the optimum kV based on the patient size and clinical task to improve the radiation dose efficiency. However, its use in pediatric CT has been mostly empirical, following manufacturer's default recommendation without solid demonstration for quality improvement. This study aimed to implement an automatic tube potential tool (CAREkV, Siemens Healthcare) into routine pediatric CT practice, using the "Plan-Do-Study-Act" quality improvement process, in place of an existing kV/mAs technique chart. The design of this quality improvement project involved Plan-Do-Study-Act stages. Plan and Do stages identified the criteria for optimal automatic kV selection; a range of phantoms representing typical pediatric groups were scanned on a dual-source 128-slice scanner using a fast-pitch scanning mode. The identified CAREkV settings were implemented into the CT protocol and evaluated after a 6-month period. In the Study stage, an objective evaluation of the image metrics and radiation dose for two similar patient cohorts using CAREkV and the technique-chart, respectively, were compared. The kV selected, image quality and radiation dose determined by CAREkV were comparable to those obtained while using the technique-chart. The CAREkV was successfully implemented into our pediatric abdominopelvic CT practice. By utilizing the "PDSA" process optimal image quality and radiation dose reduction were achieved with an automatic kV selection tool to improve CT workflow.


Assuntos
Tomografia Computadorizada por Raios X , Criança , Humanos , Imagens de Fantasmas , Doses de Radiação , Tomógrafos Computadorizados , Fluxo de Trabalho
8.
Fetal Diagn Ther ; 48(4): 258-264, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-33756472

RESUMO

INTRODUCTION: Congenital diaphragmatic hernia (CDH) affects 1 in 3,000 live births and is associated with significant morbidity and mortality. METHODS: A review of fetal magnetic resonance imaging (MRI) examinations was performed for fetuses with left CDH and normal lung controls. Image review and manual tracings were performed by 4 pediatric radiologists; right and left lung volumes in the coronal and axial planes as well as liver volume above and below the diaphragm in the coronal plane were measured. Intra- and interreviewer reproducibility was assessed using intraclass correlation coefficient (ICC) and Bland-Altman analysis. RESULTS: Excellent intra- and interreviewer reproducibility of the right and left lung volume measurements was observed in both axial planes (interreviewer ICC: right lung: 0.97, 95% CI: 0.95-0.99; left lung: 0.97, 95% CI: 0.95-0.98) and coronal planes (interreviewer ICC: right lung: 0.97, 95% CI: 0.95-0.98; left lung: 0.96, 95% CI: 0.93-0.98). Moderate-to-good interreviewer reproducibility was observed for liver volume above the diaphragm (ICC 0.7, 95% CI: 0.59-0.81). Liver volume below the diaphragm had a good-to-excellent interreviewer reproducibility (ICC 0.88, 95% CI: 9.82-0.93). CONCLUSIONS: The present study demonstrated an excellent intra- and interreviewer reproducibility of MRI lung volume measurements and good-to-moderate inter- and intrareviewer reproducibility of liver volume measurements after standardization of the methods at our fetal center.


Assuntos
Hérnias Diafragmáticas Congênitas , Criança , Feminino , Feto , Hérnias Diafragmáticas Congênitas/diagnóstico por imagem , Humanos , Fígado/diagnóstico por imagem , Pulmão/diagnóstico por imagem , Medidas de Volume Pulmonar , Imageamento por Ressonância Magnética , Gravidez , Reprodutibilidade dos Testes , Ultrassonografia Pré-Natal
9.
AJR Am J Roentgenol ; 214(5): 976-986, 2020 05.
Artigo em Inglês | MEDLINE | ID: mdl-32182093

RESUMO

OBJECTIVE. The purposes of this article are to review currently available hepatobiliary contrast agents, discuss techniques for optimization of pediatric liver MRI with hepatobiliary contrast agents, and review the imaging features of several pediatric hepatic lesions, focusing on their assessment with hepatobiliary contrast agents. CONCLUSION. MRI is the preferred imaging modality for complete assessment of focal liver lesions in the pediatric population. Imaging with gadolinium-based hepatobiliary contrast agents yields beneficial information about many focal liver lesions encountered in pediatric patients.


Assuntos
Meios de Contraste , Gadolínio DTPA , Hepatopatias/diagnóstico por imagem , Imageamento por Ressonância Magnética , Meglumina/análogos & derivados , Compostos Organometálicos , Criança , Humanos , Imageamento Tridimensional , Reconhecimento Automatizado de Padrão
10.
Med Educ ; 54(7): 637-642, 2020 07.
Artigo em Inglês | MEDLINE | ID: mdl-32119145

RESUMO

OBJECTIVES: Implicit bias is common and is thought to drive discriminatory behaviour. Having previously demonstrated discrimination against specific applicant demographics by academic radiology departments in a simulated resident selection process, the authors sought to better understand the relationship between implicit bias and discrimination, as well as the potential and mechanisms for their mitigation. METHODS: A total of 51 faculty reviewers at three academic radiology departments, who had participated in a 2017 audit study in which they were shown to treat applicants differently based on race or ethnicity and physical appearance, were invited to complete testing for implicit racial and weight bias using the Implicit Association Test in 2019. Respondents were also surveyed regarding awareness of their own personal racial and weight biases, as well as any prior participation in formal diversity training. Comparisons were made between implicit bias scores and applicant ratings, as well as between diversity training and self-awareness of bias. RESULTS: A total of 31 out of 51 faculty reviewers (61%) completed and submitted results of race and weight Implicit Association Tests. A total of 74% (23/31) reported implicit anti-obese bias, concordant with discrimination demonstrated in the resident selection simulation, in which obese applicants were rated 0.40 standard deviations (SDs) lower than non-obese applicants (P < .001). A total of 71% (22/31) reported implicit anti-Black bias, discordant with application ratings, which were 0.47 SDs higher for Black than for White applicants (P < .001). A total of 84% (26/31) of participants reported feeling self-aware of potential racial bias at the time of application review, significantly higher than the 23% (7/31) reporting self-awareness of potential anti-obese bias (P < .001). Participation in formal diversity training was not associated with implicit anti-Black or anti-fat bias, nor with self-reported awareness of potential racial or weight-based bias (all P > .2). CONCLUSIONS: These findings suggest that implicit bias, as measured by the Implicit Association Test, does not inevitably lead to discrimination, and that personal awareness of implicit biases may allow their mitigation.


Assuntos
Racismo , Radiologia , Negro ou Afro-Americano , Etnicidade , Humanos , População Branca
11.
Pediatr Radiol ; 49(1): 76-81, 2019 01.
Artigo em Inglês | MEDLINE | ID: mdl-30232533

RESUMO

BACKGROUND: Ileocolic intussusception occurs when the terminal ileum "telescopes" into the colon. We observed that ileocolic intussusception lengths are similar regardless of location in the colon. OBJECTIVE: To examine the uniformity of ileocolic intussusception length and its relationship to colon location, symptom duration and reducibility. MATERIALS AND METHODS: We retrospectively reviewed ultrasound-diagnosed pediatric ileocolic intussusceptions initially treated with pneumatic reduction at the Mayo Clinic or Texas Children's Hospital. We recorded demographic, imaging and surgical findings including age, gender, symptom duration, location of the ileocolic intussusception, reducibility with air enema and, if fluoroscopically irreducible, surgical findings. RESULTS: We identified 119 ileocolic intussusceptions (64% boys), with 81% in the right colon. There was no significant relationship between ileocolic intussusception length and colon location (P=0.15), nor ileocolic intussusception length and symptom duration (P=0.36). Ileocolic intussusceptions were more distal with increasing symptom duration (P=0.016). Successful reductions were unrelated to symptom duration (P=0.84) but were more likely with proximal versus distal locations (P=0.02). CONCLUSION: Ileocolic intussusception lengths are relatively uniform regardless of location along the course of the colon where they present. Our findings suggest that most of the apparent distal propagation of ileocolic intussusceptions is not caused by increasing telescoping of small bowel across the ileocecal valve but rather by foreshortening of the right colon. This implies poor cecal fixation and confirms fluoroscopic and surgical observations of cecal displacement from the right lower quadrant with ileocolic intussusceptions. The movement of the leading edge of the ileocolic intussusception during reduction is first due to "relocating" the cecum into the right lower quadrant after which the reduction of small bowel back across the ileocecal valve then occurs.


Assuntos
Doenças do Colo/diagnóstico por imagem , Doenças do Íleo/diagnóstico por imagem , Intussuscepção/diagnóstico por imagem , Ultrassonografia/métodos , Doenças do Colo/terapia , Feminino , Humanos , Doenças do Íleo/terapia , Lactente , Intussuscepção/terapia , Masculino , Estudos Retrospectivos , Resultado do Tratamento
12.
Pediatr Radiol ; 49(3): 429, 2019 03.
Artigo em Inglês | MEDLINE | ID: mdl-30683960

RESUMO

In this article, the fourth author's name is misspelled. The correct spelling, as shown above, should be "Nadia F. Mahmood."

13.
Pediatr Radiol ; 48(7): 1031, 2018 07.
Artigo em Inglês | MEDLINE | ID: mdl-29299620

RESUMO

The published version of this article incorrectly lists the authors' affiliations. The correct affiliations are given below. The Publisher regrets this mistake.

14.
Pediatr Radiol ; 48(7): 1021-1030, 2018 07.
Artigo em Inglês | MEDLINE | ID: mdl-29218363

RESUMO

Performing chest CT angiography on pediatric patients on extracorporeal membrane oxygenation (ECMO) can be challenging. Successfully performing CT angiography in these children requires substantial communication and coordination between the radiologists and clinical care providers. Additionally, the radiologist must understand the child's anatomy and disease pathophysiology, flow dynamics of the ECMO circuit, image acquisition timing, contrast injection site, and volume, rate and duration of contrast administration. In this article we highlight the vital factors the radiologist needs to consider to optimize the chest CT angiography in pediatric patients on ECMO.


Assuntos
Angiografia por Tomografia Computadorizada , Oxigenação por Membrana Extracorpórea , Radiografia Torácica , Criança , Humanos
19.
AJR Am J Roentgenol ; 205(1): W124-32, 2015 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-26102410

RESUMO

OBJECTIVE: Digital slot scanning is a relatively new technology that has been used for imaging of pediatric orthopedic conditions such as scoliosis and leg-length discrepancies. This article will review the clinical applications, advantages, and unique artifacts of this new technology. CONCLUSION: Upright biplanar slot scanners acquire high-resolution radiographs simultaneously in two orthogonal planes with reduced radiation dose. Other advantages include a more physiologic weightbearing imaging position, improved Cobb angle measurements, and 3D modeling.


Assuntos
Desigualdade de Membros Inferiores/diagnóstico por imagem , Intensificação de Imagem Radiográfica/métodos , Escoliose/diagnóstico por imagem , Artefatos , Criança , Humanos , Imageamento Tridimensional , Doses de Radiação , Suporte de Carga
20.
Pediatr Radiol ; 45(13): 1934-44, 2015 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-26280637

RESUMO

BACKGROUND: Ultrasonography is considered the most appropriate initial imaging study in the evaluation of acute appendicitis in children but has recently come under criticism with reports of low specificity and high indeterminate study rates, particularly when used in obese patients and patients early in the course of their disease, or when performed by sonographers with limited experience. OBJECTIVE: To (1) assess the impact of patient factors (gender, age, body mass index, and symptom duration) and system factors (call status or year of exam) on pediatric appendiceal US accuracy and indeterminate study rate, (2) assess the impact of indeterminate study results on follow-up CT and negative laparotomy rates and (3) present strategies to reduce the rate of indeterminate US studies and improve accuracy. MATERIALS AND METHODS: We retrospectively reviewed all US reports performed for the assessment of acute appendicitis in children <18 years old at Mayo Clinic Rochester from January 2010 to June 2014. RESULTS: A total of 790 US examinations were performed in 452 girls (57%) and 338 boys (43%). The prevalence of appendicitis was 18.5% (146/790). There were 109 true-positive, 440 true-negative, 17 false-positive, 6 false-negative, 218 equivocal and 41 technically inadequate US studies. A definitive interpretation was made in 72% of the studies, with an accuracy, sensitivity and specificity of 0.960, 0.948 and 0.963, respectively. No patient or system factors significantly affected US accuracy. Indeterminate studies (28%) had significantly higher CT utilization (46% vs. 11%) and normal appendectomy rates (6.9% vs. 3.5%). CONCLUSION: US should be the initial imaging study of choice for pediatric appendicitis. When a definitive interpretation was given, the accuracy was 96%, was independent of patient and system factors and resulted in reduced follow-up CTs and negative laparotomies. Accuracy can be increased by requiring the presence of periappendiceal inflammatory changes prior to interpreting a mildly distended appendix as positive for acute appendicitis. The indeterminate study rate can be reduced by not requiring visualization of the normal appendix for the exclusion of acute appendicitis.


Assuntos
Apendicite/diagnóstico por imagem , Criança , Diagnóstico Diferencial , Feminino , Humanos , Masculino , Seleção de Pacientes , Estudos Retrospectivos , Sensibilidade e Especificidade , Tomografia Computadorizada por Raios X , Ultrassonografia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA