Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 42
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
AJR Am J Roentgenol ; 219(3): 397-405, 2022 09.
Artigo em Inglês | MEDLINE | ID: mdl-35319912

RESUMO

BACKGROUND. Lung-RADS version 1.1 (v1.1) classifies all solid nodules less than 6 mm as category 2. Lung-RADS v1.1 also classifies solid intermediate-size (6 to < 10 mm) nodules as category 2 if they are perifissural and have a triangular, polygonal, or ovoid shape (indicative of intrapulmonary lymph nodes). Additional category 2 criteria could reduce false-positive results of screening examinations. OBJECTIVE. The purpose of this study was to evaluate the impact of proposed strategies for reducing false-positive results for intermediate-size nodules on lung cancer screening CT evaluated using Lung-RADS v1.1. METHODS. This retrospective study entailed secondary analysis of National Lung Screening Trial (NLST) data. Of 1387 solid nodules measuring 6.0-9.5 mm on baseline screening CT examinations in the NLST, all 38 nodules in patients who developed cancer and a random sample of 200 nodules in patients who did not develop cancer were selected for further evaluation. Cancers were required to correspond with the baseline nodule on manual review. After exclusions, the sample included 223 patients (median age, 62 years; 143 men, 80 women; 196 benign nodules, 27 malignant nodules). Two thoracic radiologists independently reviewed baseline examinations to record nodule diameter and volume using semiautomated software and to determine whether nodules had perifissural location; other subpleural location; and triangular, polygonal, or ovoid shape. Different schemes for category 2 assignment were compared. RESULTS. Across readers, standard Lung-RADS v1.1 had sensitivity of 89-93% and specificity of 26-31%. A modification assigning nodules less than 10 mm with triangular, polygonal, or ovoid shape in other subpleural locations (vs only perifissural location) as category 2 had sensitivity of 85-93% and specificity of 47-51%. Lung-RADS v1.1 using volume cutoffs had sensitivity of 89-93% and specificity of 37% (both readers). The sensitivity of both modified Lung-RADS v1.1 and Lung-RADS v1.1 with volume cutoffs was not significantly different from standard Lung-RADS v1.1 (all p > .05). However, both schemes' specificity was significantly better than standard Lung-RADS v1.1 (all p < .05). Combining the two strategies yielded sensitivity of 85-93% and specificity of 58-59%. CONCLUSION. Classifying intermediate-size nodules with triangular, polygonal, or ovoid shape in any subpleural (not just perifissural) location as category 2 and using volume- rather than diameter-based measurements improves Lung-RADS specificity without decreased sensitivity. CLINICAL IMPACT. The findings can help reduce false-positive results, decreasing 6-month follow-up examinations for benign findings.


Assuntos
Detecção Precoce de Câncer , Neoplasias Pulmonares , Detecção Precoce de Câncer/métodos , Feminino , Humanos , Pulmão/diagnóstico por imagem , Pulmão/patologia , Neoplasias Pulmonares/diagnóstico por imagem , Neoplasias Pulmonares/patologia , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Tomografia Computadorizada por Raios X/métodos
2.
AJR Am J Roentgenol ; 215(1): 116-120, 2020 07.
Artigo em Inglês | MEDLINE | ID: mdl-32160056

RESUMO

OBJECTIVE. For nondiagnostic CT-guided lung biopsies, we tested whether radiologicpathologic correlation could identify patients who may benefit from repeat biopsy. MATERIALS AND METHODS. In this retrospective study, 1525 lung biopsies were performed between July 2013 and June 2017, 243 of which were nondiagnostic. Of these 243 lung biopsies, 98 were performed to evaluate for lung malignancy; 17 were excluded because of insufficient follow-up, leaving a total of 81 cases. The Brock and Herder models were used to calculate risk; in addition, cases were independently blindly reviewed by two thoracic radiologists who assigned a score from 1 (probably benign) to 5 (probably malignant). The final diagnosis was established by pathology results or benignancy was established if the lesion resolved or remained stable for at least 2 years. RESULTS. Of the 81 nondiagnostic lung biopsies, initial pathology results included 33 cases of inflammation, 28 cases of normal lung tissue or insufficient sample, 10 cases of organizing pneumonia, and 10 cases of atypical cells. 42% (34/81) of cases were eventually determined to be malignant (negative predictive value [NPV] of 58%). Pathology results of organizing pneumonia had the lowest rate of malignancy (2/10 = 20%), and pathology results of atypical cells had the highest rate of malignancy (5/10 = 50%, p = 0.51). Within this highly selected cohort, the Brock and Herder models were not predictive of malignancy, with areas under the ROC curve (AUCs) of 0.52 and 0.52, respectively. Evaluation by thoracic radiologists yielded AUCs of 0.85 and 0.77. When radiologist-assigned scores of 1 and 2 were considered as benign, the NPV was 90% and 95%. CONCLUSION. Review of nondiagnostic lung biopsies for radiologic-pathologic concordance by thoracic radiologists can triage patients who may benefit from repeat biopsy.


Assuntos
Biópsia Guiada por Imagem/métodos , Neoplasias Pulmonares/patologia , Tomografia Computadorizada por Raios X , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos
3.
Radiology ; 293(2): 441-448, 2019 11.
Artigo em Inglês | MEDLINE | ID: mdl-31526256

RESUMO

Background Subsolid pulmonary nodules, comprising pure ground-glass nodules (GGNs) and part-solid nodules (PSNs), have a high risk of indolent malignancy. Lung Imaging Reporting and Data System (Lung-RADS) nodule management guidelines are based on expert opinion and lack independent validation. Purpose To evaluate Lung-RADS estimates of the malignancy rates of subsolid nodules, using nodules from the National Lung Screening Trial (NLST), and to compare Lung-RADS to the NELSON trial classification as well as the Brock University calculator. Materials and Methods Subsets of GGNs and PSNs were selected from the NLST for this retrospective study. A thoracic radiologist reviewed the baseline and follow-up CT images, confirmed that they were true subsolid nodules, and measured the nodules. The primary outcome for each nodule was the development of malignancy within the follow-up period (median, 6.5 years). Nodules were stratified according to Lung-RADS, NELSON trial criteria, and the Brock model. For analyses, nodule subsets were weighted on the basis of frequency in the NLST data set. Nodule stratification models were tested by using receiver operating characteristic curves. Results A total of 622 nodules were evaluated, of which 434 nodules were subsolid. At baseline, 304 nodules were classified as Lung-RADS category 2, with a malignancy rate of 3%, which is greater than the 1% in Lung-RADS (P = .004). The malignancy rate for GGNs smaller than 10 mm (two of 129, 1.3%) was smaller than that for GGNs measuring 10-19 mm (11 of 153, 6%) (P = .01). The malignancy rate for Lung-RADS category 3 was 14% (13 of 67), which is greater than the reported 2% in Lung-RADS (P < .001). The Brock model predicted malignancy better than Lung-RADS and the NELSON trial scheme (area under the receiver operating characteristic curve = 0.78, 0.70, and 0.67, respectively; P = .02 for Brock model vs NELSON trial scheme). Conclusion Subsolid nodules classified as Lung Imaging Reporting and Data System (Lung-RADS) categories 2 and 3 have a higher risk of malignancy than reported. The Brock risk calculator performed better than measurement-based classification schemes such as Lung-RADS. © RSNA, 2019 Online supplemental material is available for this article. See also the editorial by Kauczor and von Stackelberg in this issue.


Assuntos
Neoplasias Pulmonares/diagnóstico por imagem , Nódulos Pulmonares Múltiplos/diagnóstico por imagem , Tomografia Computadorizada por Raios X , Idoso , Detecção Precoce de Câncer , Feminino , Humanos , Neoplasias Pulmonares/patologia , Masculino , Pessoa de Meia-Idade , Nódulos Pulmonares Múltiplos/patologia , Lesões Pré-Cancerosas/diagnóstico por imagem , Lesões Pré-Cancerosas/patologia , Estudos Retrospectivos , Medição de Risco
4.
J Comput Assist Tomogr ; 43(1): 98-103, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-30052619

RESUMO

OBJECTIVE: We set out to evaluate a set of demographic and computed tomography imaging features for diagnosing anterior mediastinal masses. METHODS: We identified 223 patients with anterior mediastinal masses, which we divided into training and validation sets. One radiologist evaluated computed tomography imaging features on the training set. Then, predictive features were identified, and 3 radiologists evaluated these on the validation set. A naive Bayesian classifier based on the features was compared with the radiologists' first-choice diagnosis. RESULTS: Internal mammary lymphadenopathy and mediastinal encasement were strongly associated with lymphomas. Low attenuation and midline location were strongly associated with benign lesions, and older age was associated with thymic epithelial neoplasms. The average accuracy of the 3 radiologists' diagnoses was 78%, compared with 71% for the classifier. CONCLUSIONS: Nine demographic and imaging features were found to be helpful in diagnosing anterior mediastinal masses. By using these features, radiologists can suggest the diagnosis with fair accuracy.


Assuntos
Neoplasias do Mediastino/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Neoplasias do Mediastino/patologia , Mediastino/diagnóstico por imagem , Mediastino/patologia , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Reprodutibilidade dos Testes , Estudos Retrospectivos , Adulto Jovem
9.
Radiology ; 279(1): 287-96, 2016 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-26479161

RESUMO

PURPOSE: To evaluate the frequency and severity of pulmonary hemorrhage after transthoracic needle lung biopsy (TTLB) and assess possible factors associated with pulmonary hemorrhage. MATERIALS AND METHODS: This retrospective study was approved by the institutional review board. The requirement to obtain informed consent was waived. Records from 1113 patients who underwent 1175 TTLBs between January 2008 and April 2013 were retrospectively reviewed. Primary outcomes were pulmonary hemorrhage, documented hemoptysis, and bleeding complications necessitating intervention. Pulmonary hemorrhage was graded as follows: 0, none; 1, less than or equal to 2 cm around the needle; 2, more than 2 cm and sublobar; 3, at least lobar; and 4, hemothorax. Patient, technique, and lesion-related variables were evaluated as predictors of pulmonary hemorrhage. Patient-related variables included main pulmonary artery diameter (mPAD) at computed tomography (CT), pulmonary artery pressures at echocardiography and right-sided heart catheterization, medications, chronic lung disease, bleeding diathesis, and immunodeficiency. Technique- and lesion-related variables included needle gauge, number of passes, pleura-needle angle, lesion size and morphologic characteristics, and distance to pleura. Univariate analysis was performed with χ(2), Fisher exact, and Student t tests. RESULTS: Pulmonary hemorrhage occurred in 483 of the 1175 TTLBs (41.1%); hemoptysis was documented in 21 of the 1175 TTLBs (1.8%). Higher-grade hemorrhage (grade 2 or higher) occurred in 201 of the 1175 TTLBs (17.1%); five of the 1175 TTLBs (0.4%) necessitated hemorrhage-related admission. Higher-grade hemorrhage was more likely to occur with female sex (P = .001), older age (P = .003), emphysema (P = .004), coaxial technique (P = .025), nonsubpleural location (P < .001), lesion size of 3 cm or smaller (P < .001), and subsolid lesions (P = .028). Enlarged mPAD at CT (≥2.95 cm) was not significantly associated with higher-grade hemorrhage (P = .430). CONCLUSION: Pulmonary hemorrhage after TTLB is common but rarely requires intervention. An enlarged mPAD at CT may not be a risk factor for higher-grade hemorrhage.


Assuntos
Hemorragia/etiologia , Biópsia Guiada por Imagem/efeitos adversos , Pneumopatias/patologia , Tomografia Computadorizada por Raios X/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Hemorragia/diagnóstico por imagem , Humanos , Masculino , Pessoa de Meia-Idade , Radiografia Intervencionista , Estudos Retrospectivos , Fatores de Risco
10.
J Biomed Inform ; 52: 386-93, 2014 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-25117751

RESUMO

In this paper we describe an efficient tool based on natural language processing for classifying the detail state of pulmonary embolism (PE) recorded in CT pulmonary angiography reports. The classification tasks include: PE present vs. absent, acute PE vs. others, central PE vs. others, and subsegmental PE vs. others. Statistical learning algorithms were trained with features extracted using the NLP tool and gold standard labels obtained via chart review from two radiologists. The areas under the receiver operating characteristic curves (AUC) for the four tasks were 0.998, 0.945, 0.987, and 0.986, respectively. We compared our classifiers with bag-of-words Naive Bayes classifiers, a standard text mining technology, which gave AUC 0.942, 0.765, 0.766, and 0.712, respectively.


Assuntos
Angiografia/métodos , Processamento de Linguagem Natural , Embolia Pulmonar/diagnóstico por imagem , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Tomografia Computadorizada por Raios X/métodos , Algoritmos , Humanos , Curva ROC
11.
Acad Radiol ; 2024 Jun 29.
Artigo em Inglês | MEDLINE | ID: mdl-38945743

RESUMO

PURPOSE: To determine the risk of lung cancer and inter-observer agreement for small pulmonary nodules either touching or near the pleura. METHODS: Nodules were derived from two cohorts: patients from the National Lung Screening Trial with a solid nodule measuring 6-9.5 mm; and patients with incidental pulmonary nodules in our healthcare system with a solid nodule measuring 1-8 mm. Only the dominant nodule was evaluated for each patient. All malignant nodules as well as a random sample of 200 benign nodules from each cohort were included. Two fellowship-trained thoracic radiologists independently reviewed each case to record nodule morphology (compatible with lymph node or not) and nodule location (pleural-based, septal connection to the pleura, or neither). One radiologist measured the distance to the pleura. RESULTS: After exclusion criteria were applied, a total of 434 nodules were included, of which 45 were lung cancers. Considering all pleural-based nodules with lymph node morphology as benign, 0-7% of cancers were misclassified as benign, specificity 33%, and κ = 0.69. Considering subpleural nodules and those with septal connection to the pleura, 7-11% of cancers were misclassified (p = 0.16-0.25 versus pleural-based), specificity 40-52% (p < .0001), and κ = 0.60. Considering nodules with lymph node morphology ≤ 2 mm from the pleura, 2-7% of cancers were misclassified (p = 1 versus pleural-based), specificity 41-36% (p < .0001), and κ = 0.78. CONCLUSION: Considering nodules with lymph node morphology with septal connection, or those ≤ 2 mm from the pleura, as benign does not lead to significant misclassification of lung cancers as benign.

12.
J Am Coll Radiol ; 21(3): 473-488, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-37820837

RESUMO

The ACR created the Lung CT Screening Reporting and Data System (Lung-RADS) in 2014 to standardize the reporting and management of screen-detected pulmonary nodules. Lung-RADS was updated to version 1.1 in 2019 and revised size thresholds for nonsolid nodules, added classification criteria for perifissural nodules, and allowed for short-interval follow-up of rapidly enlarging nodules that may be infectious in etiology. Lung-RADS v2022, released in November 2022, provides several updates including guidance on the classification and management of atypical pulmonary cysts, juxtapleural nodules, airway-centered nodules, and potentially infectious findings. This new release also provides clarification for determining nodule growth and introduces stepped management for nodules that are stable or decreasing in size. This article summarizes the current evidence and expert consensus supporting Lung-RADS v2022.


Assuntos
Cistos , Neoplasias Pulmonares , Humanos , Neoplasias Pulmonares/diagnóstico por imagem , Neoplasias Pulmonares/terapia , Tomografia Computadorizada por Raios X , Consenso , Pulmão/diagnóstico por imagem
13.
Chest ; 165(3): 738-753, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38300206

RESUMO

The American College of Radiology created the Lung CT Screening Reporting and Data System (Lung-RADS) in 2014 to standardize the reporting and management of screen-detected pulmonary nodules. Lung-RADS was updated to version 1.1 in 2019 and revised size thresholds for nonsolid nodules, added classification criteria for perifissural nodules, and allowed for short-interval follow-up of rapidly enlarging nodules that may be infectious in etiology. Lung-RADS v2022, released in November 2022, provides several updates including guidance on the classification and management of atypical pulmonary cysts, juxtapleural nodules, airway-centered nodules, and potentially infectious findings. This new release also provides clarification for determining nodule growth and introduces stepped management for nodules that are stable or decreasing in size. This article summarizes the current evidence and expert consensus supporting Lung-RADS v2022.


Assuntos
Neoplasias Pulmonares , Nódulos Pulmonares Múltiplos , Nódulo da Glândula Tireoide , Humanos , Neoplasias Pulmonares/diagnóstico por imagem , Neoplasias Pulmonares/terapia , Tomografia Computadorizada por Raios X , Consenso , Pulmão/diagnóstico por imagem , Estudos Retrospectivos , Ultrassonografia
14.
J Comput Assist Tomogr ; 37(5): 737-42, 2013.
Artigo em Inglês | MEDLINE | ID: mdl-24045250

RESUMO

OBJECTIVE: This study aimed to evaluate the interobserver variability of right-to-left ventricular (RV/LV) diameter ratios on computed tomographic pulmonary angiographies at reduced tube potential. METHODS: Consecutive computed tomographic pulmonary angiographies performed at 80 kVp for subjects weighing less than 80 kg (n = 40) and 100 kVp for those weighing 80 kg or greater (n = 40) were selected as the low peak kilovoltage cohort, with age- and sex-matched studies performed at 120 kVp forming the controls (n = 40 each). The interobserver variability in RV/LV diameter ratio on axial and 4-chamber images was evaluated. RESULTS: Interobserver correlation was excellent at both reduced tube voltages (correlation coefficients, 0.81-0.91; P < 0.001). Bland-Altman plots indicated higher variability at lower peak kilovoltage, confirmed only for axial measurements by multivariate regression adjusting for body weight and ventricular ratio (ß coefficient = 0.04 and 0.03, P = 0.049 and 0.022, for 80 kVp and 100 kVp, respectively). CONCLUSIONS: Lower tube voltage did not affect the reproducibility of RV/LV diameter ratio on 4-chamber images; for axial measurements, the increase in variability was 3% to 4% of the average ventricular ratio.


Assuntos
Angiografia/métodos , Ventrículos do Coração/diagnóstico por imagem , Hipertrofia Ventricular Direita/diagnóstico por imagem , Hipertrofia Ventricular Direita/etiologia , Embolia Pulmonar/diagnóstico por imagem , Embolia Pulmonar/etiologia , Tomografia Computadorizada por Raios X/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Tamanho do Órgão , Doses de Radiação , Proteção Radiológica/métodos , Intensificação de Imagem Radiográfica/métodos , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Adulto Jovem
15.
Thromb Haemost ; 123(6): 649-662, 2023 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-36809777

RESUMO

BACKGROUND: Contemporary pulmonary embolism (PE) research, in many cases, relies on data from electronic health records (EHRs) and administrative databases that use International Classification of Diseases (ICD) codes. Natural language processing (NLP) tools can be used for automated chart review and patient identification. However, there remains uncertainty with the validity of ICD-10 codes or NLP algorithms for patient identification. METHODS: The PE-EHR+ study has been designed to validate ICD-10 codes as Principal Discharge Diagnosis, or Secondary Discharge Diagnoses, as well as NLP tools set out in prior studies to identify patients with PE within EHRs. Manual chart review by two independent abstractors by predefined criteria will be the reference standard. Sensitivity, specificity, and positive and negative predictive values will be determined. We will assess the discriminatory function of code subgroups for intermediate- and high-risk PE. In addition, accuracy of NLP algorithms to identify PE from radiology reports will be assessed. RESULTS: A total of 1,734 patients from the Mass General Brigham health system have been identified. These include 578 with ICD-10 Principal Discharge Diagnosis codes for PE, 578 with codes in the secondary position, and 578 without PE codes during the index hospitalization. Patients within each group were selected randomly from the entire pool of patients at the Mass General Brigham health system. A smaller subset of patients will also be identified from the Yale-New Haven Health System. Data validation and analyses will be forthcoming. CONCLUSIONS: The PE-EHR+ study will help validate efficient tools for identification of patients with PE in EHRs, improving the reliability of efficient observational studies or randomized trials of patients with PE using electronic databases.


Assuntos
Embolia Pulmonar , Humanos , Reprodutibilidade dos Testes , Embolia Pulmonar/diagnóstico , Registros Eletrônicos de Saúde , Valor Preditivo dos Testes , Classificação Internacional de Doenças , Algoritmos
16.
AJR Am J Roentgenol ; 198(6): 1353-60, 2012 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-22623548

RESUMO

OBJECTIVE: The purpose of this article is to retrospectively compare right ventricular-to-left ventricular (RV/LV) diameter ratios measured on the standard axial view versus the reformatted four-chamber view as predictors of mortality after acute pulmonary embolism (PE). MATERIALS AND METHODS: Six hundred seventy-four consecutive patients (mean age, 58 years; 372 women) with a diagnosis of acute PE on pulmonary CT angiography were considered. The axial and reformatted four-chamber RV/LV diameter ratios were compared as predictors of 30-day all-cause and PE-related mortality. RESULTS: Ninety-seven patients (14%) died within 30 days; 39 deaths were PE related. There was no significant difference in the univariate hazard ratios (HRs) of axial and four-chamber RV/LV diameter ratios greater than 0.9 for both all-cause (HR, 2.13 [95% CI, 1.29-3.51] vs HR, 1.95 [95% CI, 1.22-3.14]; p = 0.74) and PE-related (HR, 19.6 [95% CI, 2.70-143] vs HR, 21.8 [95% CI, 2.99-158]; p = 1.0) mortality. Axial and four-chamber multivariate HRs accounting for potential confounders such as age and cancer were also similar for all-cause (HR, 1.79 [95% CI, 1.07-2.99] vs HR, 1.54 [95% CI, 0.95-2.49]; p = 0.62) and PE-related (HR, 16.3 [95% CI, 2.22-119] vs HR, 17.7 [95% CI, 2.43-130]; p = 1.0) mortality. There was no significant difference in sensitivity, specificity, negative predictive value, or positive predictive value. Axial and four-chamber measurements were well correlated (correlation coefficient, 0.857), and there was no significant difference in overall accuracy for predicting all-cause (area under the curve [AUC], 0.582 vs 0.577; p = 0.72) and PE-related (AUC, 0.743 vs 0.744; p = 1.0) mortality. CONCLUSION: The axial RV/LV diameter ratio is no less accurate than the reformatted four-chamber RV/LV diameter ratio for predicting 30-day mortality after PE.


Assuntos
Angiografia/métodos , Ventrículos do Coração/diagnóstico por imagem , Embolia Pulmonar/diagnóstico por imagem , Embolia Pulmonar/mortalidade , Tomografia Computadorizada por Raios X , Comorbidade , Meios de Contraste , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Interpretação de Imagem Radiográfica Assistida por Computador , Estudos Retrospectivos , Sensibilidade e Especificidade , Taxa de Sobrevida
17.
Chest ; 160(6): 2220-2231, 2021 12.
Artigo em Inglês | MEDLINE | ID: mdl-34270966

RESUMO

BACKGROUND: Pulmonary hypertension is a heterogeneous disease, and a significant portion of patients at risk for it have CT imaging available. Advanced automated processing techniques could be leveraged for early detection, screening, and development of quantitative phenotypes. Pruning and vascular tortuosity have been previously described in pulmonary arterial hypertension (PAH), but the extent of these phenomena in arterial vs venous pulmonary vasculature and in exercise pulmonary hypertension (ePH) have not been described. RESEARCH QUESTION: What are the arterial and venous manifestations of pruning and vascular tortuosity using CT imaging in PAH, and do they also occur in ePH? STUDY DESIGN AND METHODS: A cohort of patients with PAH and ePH and control subjects with available CT angiograms were retrospectively identified to examine the differential arterial and venous presence of pruning and tortuosity in patients with precapillary pulmonary hypertension not confounded by lung or thromboembolic disease. The pulmonary vasculature was reconstructed, and an artificial intelligence method was used to separate arteries and veins and to compute arterial and venous vascular volumes and tortuosity. RESULTS: A total of 42 patients with PAH, 12 patients with ePH, and 37 control subjects were identified. There was relatively lower (median [interquartile range]) arterial small vessel volume in subjects with PAH (PAH 14.7 [11.7-16.5; P < .0001]) vs control subjects (16.9 [15.6-19.2]) and venous small vessel volume in subjects with PAH and ePH (PAH 8.0 [6.5-9.6; P < .0001]; ePH, 7.8 [7.5-11.4; P = .004]) vs control subjects (11.5 [10.6-12.2]). Higher large arterial volume, however, was only observed in the pulmonary arteries (PAH 17.1 [13.6-23.4; P < .0001] vs control subjects 11.4 [8.1-15.4]). Similarly, tortuosity was higher in the pulmonary arteries in the PAH group (PAH 3.5 [3.3-3.6; P = .0002] vs control 3.2 [3.2-3.3]). INTERPRETATION: Lower small distal pulmonary vascular volume, higher proximal arterial volume, and higher arterial tortuosity were observed in PAH. These can be quantified by using automated techniques from clinically acquired CT scans of patients with ePH and resting PAH.


Assuntos
Hipertensão Arterial Pulmonar/diagnóstico por imagem , Tomografia Computadorizada por Raios X , Adulto , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Hipertensão Arterial Pulmonar/fisiopatologia , Artéria Pulmonar/diagnóstico por imagem , Artéria Pulmonar/fisiopatologia , Veias Pulmonares/diagnóstico por imagem , Veias Pulmonares/fisiopatologia , Testes de Função Respiratória , Estudos Retrospectivos
18.
Circ Cardiovasc Imaging ; 14(9): e012347, 2021 09.
Artigo em Inglês | MEDLINE | ID: mdl-34544259

RESUMO

BACKGROUND: In acute pulmonary embolism, chest computed tomography angiography derived metrics, such as the right ventricle (RV): left ventricle ratio are routinely used for risk stratification. Paucity of intraparenchymal blood vessels has previously been described, but their association with clinical biomarkers and outcomes has not been studied. We sought to determine if small vascular volumes measured on computed tomography scans were associated with an abnormal RV on echocardiography and mortality. We hypothesized that decreased small venous volume would be associated with greater RV dysfunction and increased mortality. METHODS: A retrospective cohort of patients with intermediate risk pulmonary embolism admitted to Brigham and Women's Hospital between 2009 and 2017 was assembled, and clinical and radiographic data were obtained. We performed 3-dimensional reconstructions of vasculature to assess intraparenchymal vascular volumes. Statistical analyses were performed using multivariable regression and cox proportional hazards models, adjusting for age, sex, lung volume, and small arterial volume. RESULTS: Seven hundred twenty-two subjects were identified of whom 573 had documented echocardiography. A 50% reduction in small venous volume was associated with an increased risk of RV dilation (relative risk: 1.38 [95% CI, 1.18-1.63], P<0.001), RV dysfunction (relative risk: 1.62 [95% CI, 1.36-1.95], P<0.001), and RV strain (relative risk: 1.67 [95% CI, 1.37-2.04], P<0.001); increased cardiac biomarkers, and higher 30-day and 90-day mortality (hazard ratio: 2.50 [95% CI, 1.33-4.67], P=0.004 and hazard ratio: 1.84 [95% CI, 1.11-3.04], P=0.019, respectively). CONCLUSIONS: Loss of small venous volume quantified from computed tomography angiography is associated with increased risk of abnormal RV on echocardiography, abnormal cardiac biomarkers, and higher risk of 30- and 90-day mortality. Small venous volume may be a useful marker for assessing disease severity in acute pulmonary embolism.


Assuntos
Ventrículos do Coração/diagnóstico por imagem , Artéria Pulmonar/diagnóstico por imagem , Embolia Pulmonar/mortalidade , Medição de Risco/métodos , Disfunção Ventricular Direita/fisiopatologia , Doença Aguda , Idoso , Angiografia por Tomografia Computadorizada , Ecocardiografia/métodos , Feminino , Seguimentos , Ventrículos do Coração/fisiopatologia , Humanos , Masculino , Pessoa de Meia-Idade , Prognóstico , Artéria Pulmonar/fisiopatologia , Embolia Pulmonar/complicações , Embolia Pulmonar/fisiopatologia , Estudos Retrospectivos , Índice de Gravidade de Doença , Taxa de Sobrevida/tendências , Estados Unidos/epidemiologia , Disfunção Ventricular Direita/diagnóstico , Disfunção Ventricular Direita/etiologia
19.
AJR Am J Roentgenol ; 195(2): W118-24, 2010 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-20651170

RESUMO

OBJECTIVE: The purpose of our study was to evaluate whether a reduced volume of iodinated contrast material for pulmonary CT angiography (CTA) using a low peak kilovoltage (kVp) technique yields equivalent opacification in all vessels. MATERIALS AND METHODS: Four hundred fifty-two consecutive pulmonary CTA patients (265 women and 187 men; age range, 18-91 years; mean age, 56.2 years) were retrospectively evaluated. Patients were grouped into those receiving 125 mL (n = 229) and 75 mL (n = 223) of 370 mg I/mL iodinated contrast material. Low kVp was used in all patients. Hounsfield units were measured at lobar, posterobasal segment, posterobasal ramus, and medial basal subsegmental ramus in the left lower lobe. Three thoracic radiologists blinded to contrast dose independently and randomly evaluated the quality of enhancement using a 3-point scale at the same levels. The two-sample Student's t test was used to compare contrast opacification between groups; Spearman's correlation and the C-statistic were used to assess objective and subjective measurements. Interreader agreement was measured using Kendall's coefficient. RESULTS: Mean contrast opacification differences between 125 mL versus 75 mL were not statistically significant (p > 0.21) at the lobar, segmental, and posterior basal rami, although the mean trended (p = 0.07) toward higher opacification of the medial basal ramus among 75 mL patients. Across all four pulmonary artery segments, there was good concordance between subjective and objective measurements, significantly higher than the null value of 0.50 (p > 0.05). For subsegmental arteries, concordance between objective and subjective measures was greater for the 75 mL group (p < 0.05). There was good interreader concordance, with a concordance coefficient of 0.70 (95% CI, 0.66-0.74). CONCLUSION: Both objective and subjective measures of contrast opacification support a reduction from 125 to 75 mL of contrast medium required for pulmonary CTA.


Assuntos
Angiografia/métodos , Iodo , Artéria Pulmonar/diagnóstico por imagem , Intensificação de Imagem Radiográfica/métodos , Tomografia Computadorizada por Raios X/métodos , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Meios de Contraste/administração & dosagem , Feminino , Humanos , Iodo/administração & dosagem , Masculino , Pessoa de Meia-Idade , Variações Dependentes do Observador , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Adulto Jovem
20.
J Am Coll Radiol ; 17(8): 1056-1060, 2020 08.
Artigo em Inglês | MEDLINE | ID: mdl-32590015

RESUMO

PURPOSE: The aim of this study was to evaluate the adoption and outcomes of locally designed reporting guidelines for patients with possible coronavirus disease 2019 (COVID-19). METHODS: A departmental guideline was developed for radiologists that specified reporting terminology and required communication for patients with imaging findings suggestive of COVID-19, on the basis of patient test status and imaging indication. In this retrospective study, radiology reports completed from March 1, 2020, to May 3, 2020, that mentioned COVID-19 were reviewed. Reports were divided into patients with known COVID-19, patients with "suspected" COVID-19 (having an order indication of respiratory or infectious signs or symptoms), and "unsuspected patients" (other order indications, eg, trauma or non-chest pain). The primary outcome was the percentage of COVID-19 reports using recommended terminology; the secondary outcome was percentages of suspected and unsuspected patients diagnosed with COVID-19. Relationships between categorical variables were assessed using the Fisher exact test. RESULTS: Among 77,400 total reports, 1,083 suggested COVID-19 on the basis of imaging findings; 774 of COVID-19 reports (71%) used recommended terminology. Of 574 patients without known COVID-19 at the time of interpretation, 345 (60%) were eventually diagnosed with COVID-19, including 61% (315 of 516) of suspected and 52% (30 of 58) of unsuspected patients. Nearly all unsuspected patients (46 of 58) were identified on CT. CONCLUSIONS: Radiologists rapidly adopted recommended reporting terminology for patients with suspected COVID-19. The majority of patients for whom radiologists raised concern for COVID-19 were subsequently diagnosed with the disease, including the majority of clinically unsuspected patients. Using unambiguous terminology and timely notification about previously unsuspected patients will become increasingly critical to facilitate COVID-19 testing and contact tracing as states begin to lift restrictions.


Assuntos
Infecções por Coronavirus/diagnóstico por imagem , Fidelidade a Diretrizes/estatística & dados numéricos , Pneumonia Viral/diagnóstico por imagem , Guias de Prática Clínica como Assunto , Radiologistas/normas , Serviço Hospitalar de Radiologia/normas , Projetos de Pesquisa/normas , COVID-19 , Estudos de Coortes , Infecções por Coronavirus/epidemiologia , Feminino , Humanos , Masculino , Avaliação de Resultados em Cuidados de Saúde , Pandemias , Pneumonia Viral/epidemiologia , Valor Preditivo dos Testes , Radiografia Torácica/métodos , Radiografia Torácica/estatística & dados numéricos , Estudos Retrospectivos , Tomografia Computadorizada por Raios X/métodos , Tomografia Computadorizada por Raios X/estatística & dados numéricos , Estados Unidos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA