Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
J Prosthet Dent ; 2024 May 09.
Artigo em Inglês | MEDLINE | ID: mdl-38729790

RESUMO

STATEMENT OF PROBLEM: The stability of mandibular removable partial dentures with bilateral distal extensions may be improved with the controlled tissue support achieved by using the altered cast impression technique, although this process is time-consuming and technique-sensitive. PURPOSE: The purpose of this pilot clinical study was to compare casts generated from a conventional definitive impression with casts generated from an altered cast impression using a 3-dimensional (3D) analysis software program. MATERIAL AND METHODS: Three partially edentulous participants with mandibular Kennedy Class I were enrolled, and impressions were made with the 2 techniques and poured in stone. The casts were scanned, aligned, and superimposed by using a 3D analysis software program. Surface deviations were measured to evaluate the differences in displacement induced by the impression on the tissue surface. Five observations were made in 4 different areas on each partially edentulous side. Means from these observations were generated, and the Wilcoxon and Mann Whitney tests were performed for all data to assess the differences between the right and left sides in the same participant and among the 3 participants (α=.05). RESULTS: The casts made from the altered cast impression had an overall mean ±standard deviation displacement of -0.05 ±1.25 mm on the right and left sides of the mandibular buccal shelf area. Moreover, the greatest overall difference of about 0.45 ±0.41 mm occurred on the lingual slope of the residual ridge, and the differences in the other areas were 0.10 ±0.99 mm (crest of the residual ridge) and 0.16 ±0.66 mm (buccal slope of the residual ridge). The overall differences varied statistically between significance and nonsignificance for the same participant and among the 3 participants. CONCLUSIONS: A digital comparative analysis of the conventional and altered cast methods of recording the bilateral distal extension areas in partially edentulous participants showed that the altered cast method exhibited more displacement on the buccal vestibule or buccal shelf area compared with other examined areas. The differences between the 2 impression methods in the displacement values among the examined areas were minimal and in close proximity, and such differences may lack clinical significance.

2.
J Prosthet Dent ; 2024 Jul 23.
Artigo em Inglês | MEDLINE | ID: mdl-39048390

RESUMO

STATEMENT OF PROBLEM: Studies on the biomechanics of obturators in the currently used designs of Aramany class I defect are lacking. Also, modifications of the designs presently used in unilateral palatal defects are needed to produce a prosthesis with more retention and less stress on the abutments. PURPOSE: The purpose of part I of this study was to differentiate among Aramany class I obturators of 4 designs regarding retention and associated stress using numerical and experimental methods. MATERIAL AND METHODS: Four finite element models and 36 different base obturators were fabricated and divided into 9 acrylic resin bases retained with Adams clasps and 9 linear, 9 tripodal, and 9 fully tripodal design obturators from casts obtained from a scanned skull. After modification, the prostheses were fabricated on the casts obtained from a 3-dimensionally printed cast. The retention was evaluated, and the data were collected and analyzed using a statistical software program (α=.05). The displacement and associated stress in the assorted casts were compared by using 5-N displacing force at 3 points using finite element analysis. The quantitative assessment was made by measuring the displacement and von Mises stress distribution on the prostheses and their supporting structures. The qualitative analysis was done by using a visual color mapping to depict stress location and intensity. RESULTS: No significant differences were found between fully tripodal (4.478 ±2.303 MPa) and tripodal obturators (4.478 ±2.286 MPa; P=.153), although fully tripodal showed more resistance to anterior displacement (4.522 ±0.979 and 3.553 ±1.58 MPa for fully tripodal and tripodal designs, respectively; P=.007), and tripodal obturators produced more resistance to middle displacement (5.441 ±1.778 and 2.784 ±0.432 MPa for tripodal and fully tripodal design respectively; P=.001). The fully tripodal obturator showed more retention (3.736 ±1.182 MPa) than the linear one (2.493 ±1.052 MPa; P=.001). The maxillary central incisor was the most stressed abutment, followed by the lateral incisor, while the second molar was the least. CONCLUSIONS: Regarding retention, the fully tripodal obturator produces retention comparable with the tripodal and significantly more than the linear. Acrylic resin prostheses retained with Adams clasps may be similar to metal-based prostheses regarding retention and stress distribution on the supporting structures.

3.
Quintessence Int ; 55(6): 430-440, 2024 06 28.
Artigo em Inglês | MEDLINE | ID: mdl-38847140

RESUMO

OBJECTIVE: Artificial intelligence (AI) applications in restorative dentistry have remarkably increased in the past 5 years. This review outlines the applications, promises, and limitations of AI in the most performed procedures in restorative dentistry. METHOD AND MATERIALS: An electronic search was performed in four databases: MEDLINE/PubMed, Embase, Web of Science, and Scopus. The search included articles published in English language without date restriction. Two independent reviewers assessed the eligibility of the studies and performed data extraction. Any discrepancy was resolved by the consensus of a third reviewer. RESULTS: A total of 33 studies were included in this review. For AI applications in restorative dentistry, the included studies were classified into three main groups: (1) diagnosis, detection, and prediction of the disease, (2) detection and prediction of the longevity of dental restorations, and (3) teeth detection and treatments. For each study, the AI model, type of dataset, sample size, and main results (accuracy, precision, sensitivity, and specificity) were reported. CONCLUSIONS: AI systems are promising as advantageous aids for diagnosis, prediction, and treatment in dentistry, with a high degree of accuracy. Despite the AI promises, several limitations are still unresolved and must be addressed to bridge the gap between technology and clinical applications.


Assuntos
Inteligência Artificial , Restauração Dentária Permanente , Humanos , Restauração Dentária Permanente/métodos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA