Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 181
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
J Appl Clin Med Phys ; : e14467, 2024 Jul 23.
Artigo em Inglês | MEDLINE | ID: mdl-39042480

RESUMO

PURPOSE: Currently, precise patient body weight (BW) at the time of diagnostic imaging cannot always be used for radiation dose management. Various methods have been explored to address this issue, including the application of deep learning to medical imaging and BW estimation using scan parameters. This study develops and evaluates machine learning-based BW prediction models using 11 features related to radiation dose obtained from computed tomography (CT) scans. METHODS: A dataset was obtained from 3996 patients who underwent positron emission tomography CT scans, and training and test sets were established. Dose metrics and descriptive data were automatically calculated from the CT images or obtained from Digital Imaging and Communications in Medicine metadata. Seven machine-learning models and three simple regression models were employed to predict BW using features such as effective diameter (ED), water equivalent diameter (WED), and mean milliampere-seconds. The mean absolute error (MAE) and correlation coefficient between the estimated BW and the actual BW obtained from each BW prediction model were calculated. RESULTS: Our results found that the highest accuracy was obtained using a light gradient-boosting machine model, which had an MAE of 1.99 kg and a strong positive correlation between estimated and actual BW (ρ = 0.972). The model demonstrated significant predictive power, with 73% of patients falling within a ±5% error range. WED emerged as the most relevant dose metric for BW estimation, followed by ED and sex. CONCLUSIONS: The proposed machine-learning approach is superior to existing methods, with high accuracy and applicability to radiation dose management. The model's reliance on universal dose metrics that are accessible through radiation dose management software enhances its practicality. In conclusion, this study presents a robust approach for BW estimation based on CT imaging that can potentially improve radiation dose management practices in clinical settings.

2.
Pediatr Cardiol ; 44(3): 624-630, 2023 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-35943519

RESUMO

The study aimed to investigate the long-term influence of atrial switch on post-Rastelli hemodynamic condition. Of 112 patients with transposition of the great arteries (TGA) or TGA-type double outlet right ventricle, ventricular septal defect (VSD), and pulmonary stenosis (PS) who underwent intra-cardiac repair between 1979 and 2018, 50 patients with levo-TGA underwent atrial switch and Rastelli as an anatomic repair and 62 patients with dextro-TGA underwent Rastelli. Postoperative outcomes were retrospectively compared. The median follow-up durations were 20.1 years (interquartile range: 4.3, 32.4) in the Rastelli group and 15.3 years (7.1, 23.0) in the atrial switch plus Rastelli group (p = 0.19). Sex, age, and weight at operation were similar in both groups. Overall survival rates at 30 years were 69.8% in the Rastelli group and 80.1% in the atrial switch plus Rastelli group (p = 0.18). The atrial switch plus Rastelli group required more frequent catheter interventions (p < 0.001), mainly for caval obstruction (n = 8) and atrial arrhythmia (n = 6). Medication was more frequent in the atrial switch plus Rastelli group (p = 0.009). Exercise capacity was similarly reduced in two groups. Protein-losing enteropathy (PLE) occurred in three long-term survivors in the atrial switch plus Rastelli group (p = 0.07). Concomitantly performed atrial switch operation did not affect long-term survival and exercise capacity after Rastelli procedure. However, the occurrence of PLE, a frequent need for medication, and catheter interventions after atrial switch plus Rastelli may result from atrial switch under the post-Rastelli condition.


Assuntos
Transposição das Grandes Artérias , Fibrilação Atrial , Transposição dos Grandes Vasos , Humanos , Lactente , Transposição dos Grandes Vasos/cirurgia , Estudos Retrospectivos , Resultado do Tratamento , Hemodinâmica
3.
Cardiol Young ; 33(3): 383-387, 2023 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-35351222

RESUMO

The prevalence of congenital left main coronary artery atresia is very low. We report the characteristics and long-term outcomes of four children with left main coronary artery atresia. Three patients had heart murmurs due to mitral regurgitation at less than 1 year old. Their myocardial ischaemia worsened on exercise with aging. In the fourth patient, hypertrophic cardiomyopathy and Noonan syndrome were suspected at 1 year old. The development of communicating arteries between the conus branch and the left anterior descending artery was detected at 7 years old. The left main coronary artery atresia was confirmed by a selective coronary angiogram at 15 years old. Congenital left main coronary artery atresia could not be diagnosed by two-dimensional echocardiography; however, the left coronary arteries were small. Two patients underwent coronary artery bypass grafting of the left anterior descending artery using the left internal thoracic artery at 3 years and 6 years old, respectively. Two patients had an angioplasty with a cut back at the orifice of the left coronary artery at 2 years old and 17 years old, respectively. Two patients had no cardiac events without medication for more than 30 years after the operation. We must differentiate the diagnosis of left main coronary artery atresia in the small left coronary arteries with mitral regurgitation during the first year. Coronary artery revascularisation and mitral annuloplasty are needed. The long-term outcome of both coronary artery bypass grafting and angioplasty were good. The degree of mitral regurgitation after surgery may affect the prognosis.


Assuntos
Doença da Artéria Coronariana , Insuficiência da Valva Mitral , Isquemia Miocárdica , Criança , Humanos , Adolescente , Pré-Escolar , Lactente , Insuficiência da Valva Mitral/diagnóstico , Insuficiência da Valva Mitral/cirurgia , Insuficiência da Valva Mitral/etiologia , Ponte de Artéria Coronária/métodos , Isquemia Miocárdica/etiologia , Doença da Artéria Coronariana/etiologia , Resultado do Tratamento
4.
Circ J ; 86(1): 138-146, 2021 12 24.
Artigo em Inglês | MEDLINE | ID: mdl-34497162

RESUMO

BACKGROUND: Pregnant women with a Fontan circulation have a high risk of obstetric complications, such as preterm delivery and small for gestational age (SGA), which may be affected by low blood flow to the placenta and hypoxia. This study investigated placental pathology in a Fontan circulation.Methods and Results:Eighteen pregnancies in 11 women with a Fontan circulation were reviewed. Pregnancy outcomes showed 9 miscarriages and 9 live births, with 4 preterm deliveries. Five neonates were SGA (<5th percentile). Eight placentas from live births in 7 women were available for the study. Five placentas had low weight placenta for gestational age, and 7 grossly showed a chronic subchorionic hematoma. Histological examination revealed all placentas had some form of histological hypoxic lesions: maternal vascular malperfusion in 7, fetal vascular malperfusion in 1, and other hypoxia-related lesions in 8. Quantitative analyses, including immunohistochemistry (CD31, CD68, and hypoxia inducible factor-1α antibodies) and Masson's trichrome staining, were also performed and compared with 5 control placentas. Capillary density and the area of fibrosis were significantly greater in placentas from women with a Fontan circulation than in control placentas. CONCLUSIONS: Placentas in a Fontan circulation were characterized by a high frequency of low placental weight, chronic subchorionic hematoma, and constant histological hypoxic changes, which could reflect altered maternal cardiac conditions and lead to poor pregnancy outcomes.


Assuntos
Técnica de Fontan , Criança , Feminino , Retardo do Crescimento Fetal , Técnica de Fontan/efeitos adversos , Hematoma , Humanos , Hipóxia/patologia , Recém-Nascido , Recém-Nascido Pequeno para a Idade Gestacional , Placenta/irrigação sanguínea , Placenta/patologia , Gravidez
5.
Heart Vessels ; 36(9): 1384-1391, 2021 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-33649908

RESUMO

Heterograft and artificial materials have been used for extracardiac conduit implantation to create right ventricular (RV) to pulmonary artery (PA) continuity for biventricular repair in Japan because of the limited availability of homograft valves. However, few studies have examined morphological changes and number of candidates for transcatheter pulmonary valve implantation (TPVI) in which the conduit includes more than one type of material. Overall, 88 patients who underwent biventricular repair with an external conduit were included in this evaluation. Based on catheterization data and surgical records, we estimated morphological change in the RV outflow tract for each material and the number of candidates for Melody valve implantation based on premarket approval application criteria established by the U.S. Food and Drug Administration. There were 63 candidates for TPVI (72%, 63/88). Median anteroposterior and lateral diameter of the RV outflow tract was 20.4 mm (range 9.0-41.5) and 17.8 mm (range 9.5-34.9), respectively. Bovine pericardium tended to dilate by 11.2%. Polytetrafluoroethylene (ePTFE), homograft, and Dacron polyethylene terephthalate (PET) tended to become stenotic by 11.1%, 28.0%, and 13.4%, respectively. While ePTFE (27/33, 82%) and Dacron PET (2/2, 100%) were highly suitable for TPVI, bovine pericardium (32/48, 67%) was less suitable. In Japan, many patients with hemodynamic indications for TPVI following extracardiac conduit implantation to create RV to PA continuity may also meet the morphological indications.


Assuntos
Implante de Prótese de Valva Cardíaca , Próteses Valvulares Cardíacas , Valva Pulmonar , Obstrução do Fluxo Ventricular Externo , Animais , Cateterismo Cardíaco , Bovinos , Xenoenxertos , Humanos , Polietilenotereftalatos , Valva Pulmonar/diagnóstico por imagem , Valva Pulmonar/cirurgia , Estudos Retrospectivos , Resultado do Tratamento
6.
J Artif Organs ; 24(3): 398-401, 2021 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-33416978

RESUMO

Two neonates with right atrial isomerism, single right ventricle, common atrioventricular valve regurgitation, and obstructive extra-cardiac total anomalous pulmonary venous connection underwent emergent total anomalous pulmonary venous connection repair combined with adjustment of pulmonary blood flow soon after birth. After the operation, both patients developed serious capillary leak syndrome, acute kidney injury, and lethal lactic acidosis with hemodynamic instability. Continuous renal replacement therapy was initiated with a cytokine-adsorbing hemofilter of polymethyl methacrylate membrane and a double lumen dialysis catheter inserted directly into the atrium. Elevated serum lactate levels were successfully decreased, and blood pressure was immediately increased.


Assuntos
Procedimentos Cirúrgicos Cardíacos , Citocinas , Átrios do Coração , Humanos , Recém-Nascido , Terapia de Substituição Renal
7.
Pediatr Cardiol ; 42(6): 1356-1364, 2021 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-33881601

RESUMO

The study aimed to assess the long-term outcomes after fenestration closure in patients at risk for Fontan failure. Of 119 patients who underwent Fontan operation between 1995 and 2004, fenestration was not created in 89 patients (NF group) and created in 30 patients with hypoplastic left heart syndrome, heterotaxy syndrome, high pulmonary arterial pressure, high systemic ventricular end-diastolic pressure, low ventricular ejection fraction, or atrioventricular valve regurgitation. All fenestrations were closed spontaneously or by catheter/surgical interventions, excepting two patients, and therefore, they were excluded. In fenestration group, patients with pre-Fontan mean pulmonary arterial pressure ≥ 15 mmHg or systemic atrioventricular valve regurgitation ≥ moderate were classified as high-risk Fontan candidates (F-HR group, n = 16), and the remaining patients were as standard-risk (F-SR group, n = 12). Protein-losing enteropathy-free survival rates did not differ among the three groups (p = 0.72). Serial follow-up catheter examinations after Fontan operation were completed in 69 patients in NF group and 11 patients in both F-SR and F-HR groups. Cardiac index and pulmonary vascular resistance significantly and similarly decreased over time in all groups, though the F-HR group showed lowest arterial oxygen saturation, lowest cardiac index, and highest pulmonary vascular resistance. The F-HR group also showed much veno-venous collaterals (p = 0.049), low peak oxygen consumption (p = 0.019), and low anaerobic threshold (p = 0.023) as compared to those in the F-SR group. In F-HR group, cyanosis remained after fenestration closure due to transformation from fenestration to veno-venous collaterals, which resulted in elevation of pulmonary vascular resistance, low cardiac index, and deterioration of exercise tolerance.


Assuntos
Técnica de Fontan/métodos , Cardiopatias Congênitas/cirurgia , Hemodinâmica/fisiologia , Cateterismo Cardíaco/métodos , Criança , Pré-Escolar , Feminino , Seguimentos , Cardiopatias Congênitas/fisiopatologia , Ventrículos do Coração/fisiopatologia , Humanos , Masculino , Fatores de Tempo , Resultado do Tratamento
8.
J Appl Clin Med Phys ; 22(2): 165-177, 2021 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-33426812

RESUMO

PURPOSE: A high-energy-resolution whole-body SPECT-CT device (NM/CT 870 CZT; C-SPECT) equipped with a CZT detector has been developed and is being used clinically. A MEHRS collimator has also been developed recently, with an expected improvement in imaging accuracy using medium-energy radionuclides. The objective of this study was to compare and analyze the accuracies of the following devices: a WEHR collimator and the MEHRS collimator installed on a C-SPECT, and a NaI scintillation detector-equipped Anger-type SPECT (A-SPECT) scanner, with a LEHR and LMEGP. METHODS: A line phantom was used to measure the energy resolutions including collimator characteristics in the planar acquisition of each device using 99m Tc and 123 I. We also measured the system's sensitivity and high-contrast resolution using a lead bar phantom. We evaluated SPECT spatial resolution, high-contrast resolution, radioactivity concentration linearity, and homogeneity, using a basic performance evaluation phantom. In addition, the effect of scatter correction was evaluated by varying the sub window (SW) employed for scattering correction. RESULTS: The energy resolution with 99m Tc was 5.6% in C-SPECT with WEHR and 9.9% in A-SPECT with LEHR. Using 123I, the results were 9.1% in C-SPECT with WEHR, 5.5% in C-SPECT with MEHRS, and 10.4% in A-SPECT with LMEGP. The planar spatial resolution was similar under all conditions, but C-SPECT performed better in SPECT acquisition. High-contrast resolution was improved in C-SPECT under planar condition and SPECT. The sensitivity and homogeneity were improved by setting the SW for scattering correction to 3% of the main peak in C-SPECT. CONCLUSION: C-SPECT demonstrates excellent energy resolution and improved high-contrast resolution for each radionuclide. In addition, when using 123I, careful attention should be paid to SW for scatter correction. By setting the appropriate SW, C-SPECT with MEHRS has an excellent scattered ray removal effect, and highly homogenous imaging is possible while maintaining the high-contrast resolution.


Assuntos
Cádmio , Telúrio , Humanos , Imagens de Fantasmas , Tomografia Computadorizada de Emissão de Fóton Único , Tomografia Computadorizada por Raios X , Zinco
9.
Artigo em Japonês | MEDLINE | ID: mdl-33473078

RESUMO

Validation study of simulation codes was performed based on the measurement of a sphere phantom and the National Electrical Manufacturers Association (NEMA) body phantoms. SIMIND and Prominence Processor were used for the simulation. Both source and density maps were generated using the characteristics of 99mTc energy. A full width at half maximum (FWHM) of the sphere phantom was measured and simulated. Simulated recovery coefficient and the background count coefficient of variation were also compared with the measured values in the body phantom study. When the two simulation codes were compared with actual measurements, maximum relative errors of FWHM values were 3.6% for Prominence Processor and -10.0% for SIMIND. The maximum relative errors of relative recovery coefficients exhibited 11.8% for Prominence Processor and -2.0% for SIMIND in the body phantom study. The coefficients of variation of the SPECT count in the background were significantly different among the measurement and two simulation codes. The simulated FWHM values and recovery coefficients paralleled measured results. However, the noise characteristic differed among actual measurements and two simulation codes in the background count statistics.


Assuntos
Tomografia Computadorizada de Emissão de Fóton Único , Simulação por Computador , Imagens de Fantasmas
10.
Circ J ; 84(3): 495-500, 2020 02 25.
Artigo em Inglês | MEDLINE | ID: mdl-32023573

RESUMO

BACKGROUND: The aim of this study was to assess the impact of surgeon years of experience on clinical outcomes of tetralogy of Fallot (TOF) repair using technical performance score (TPS), and to investigate the possibility of safe operations by surgical trainees.Methods and Results:We assessed the cases of 159 consecutive patients who underwent TOF repair between 2001 and 2015. Thirteen different primary surgeons performed operations with 41 different first assistants. The primary surgeon and first assistant mean postgraduate years were 19.1±5.1 years (range, 5.7-31.6 years) and 11.2±6.3 years (range, 3.2-36.3 years), respectively. TPS was assigned using pre-discharge echocardiography based on original criteria. Logistic regression analysis was used to examine the factors associated with TPS. TPS could be scored for all patients, 16 of whom were graded as having optimal (10%), 119 as adequate (75%), and 24 as having inadequate (15%) TPS. None of the preoperative and perioperative variables affected TPS. Although neither the primary surgeon nor the first assistant postgraduate years was associated with TPS independently, total primary surgeon and first assistant postgraduate years correlated with TPS (OR, 1.07; 95% CI: 1.01-1.13, P=0.031). CONCLUSIONS: Primary surgeon postgraduate years was not associated with TPS for TOF repair. TOF repair can be performed adequately and safely by surgical trainees under the support of highly experienced supervisors.


Assuntos
Procedimentos Cirúrgicos Cardíacos/educação , Cardiologistas/educação , Competência Clínica , Educação de Pós-Graduação em Medicina , Cirurgiões/educação , Tetralogia de Fallot/cirurgia , Procedimentos Cirúrgicos Cardíacos/efeitos adversos , Pré-Escolar , Humanos , Lactente , Japão , Estudos Retrospectivos , Medição de Risco , Fatores de Risco , Análise e Desempenho de Tarefas , Tetralogia de Fallot/diagnóstico por imagem , Tetralogia de Fallot/fisiopatologia , Resultado do Tratamento
11.
Circ J ; 84(12): 2275-2285, 2020 11 25.
Artigo em Inglês | MEDLINE | ID: mdl-33148938

RESUMO

BACKGROUND: Congenital heart disease (CHD) is often diagnosed prenatally using fetal echocardiography, but few studies have evaluated the accuracy of these fetal cardiac diagnoses in detail. We investigated the discrepancy between pre- and postnatal diagnoses of CHD and the impact of discrepant diagnoses.Methods and Results:This retrospective study at a tertiary institution included data from the medical records of 207 neonates with prenatally diagnosed CHD admitted to the cardiac neonatal intensive care unit between January 2011 and December 2016. Pre- and postnatal diagnoses of CHD differed in 12% of neonates. Coarctation of the aorta and ventricular septal defects were the most frequent causes of discrepant diagnosis. Unexpected treatments were added to 38% of discrepant diagnostic cases. However, discrepant diagnoses did not adversely affect the clinical course. The 9% of the 207 neonates who required invasive intervention within 24 h of delivery were accurately diagnosed prenatally. CONCLUSIONS: Pre- and postnatal diagnoses differed in only a few neonates, with differences not adversely affecting the clinical course. Neonates who required invasive intervention immediately after delivery were accurately diagnosed prenatally. Prenatal diagnosis thus seems to contribute to improved prognosis in neonates with CHD.


Assuntos
Cardiopatias Congênitas , Triagem Neonatal , Diagnóstico Pré-Natal , Ecocardiografia , Feminino , Cardiopatias Congênitas/diagnóstico por imagem , Humanos , Recém-Nascido , Japão/epidemiologia , Gravidez , Estudos Retrospectivos
12.
Artigo em Japonês | MEDLINE | ID: mdl-32201419

RESUMO

The aim of the present study was to clarify the routine protocols and the frequency of added or omitted imaging on nuclear medicine imaging in Japan. A nationwide survey on routine protocols and current state of added or omitted imaging in major nuclear medicine imaging were performed for Japanese nuclear medicine technologist. The survey showed that the routine protocols were almost 100% fixed, some of the routine protocols were found to be useful and percentage of imaging techniques such as single photon emission computed tomography/computed tomography that increased patient burden and reduced through put were low. Furthermore, the survey showed that additional or omission imaging were frequently performed on bone scintigraphy and positron emission tomography and added or omitted judgements were often depend upon the rule of thumb by nuclear medicine technologist. In this study, we have concluded that the quality of examination and the diagnosis might depend on the knowledge of nuclear medicine technologist, performed added or omitted imaging.


Assuntos
Medicina Nuclear , Humanos , Japão , Tomografia por Emissão de Pósitrons , Cintilografia , Inquéritos e Questionários , Tomografia Computadorizada de Emissão de Fóton Único
13.
Heart Vessels ; 34(8): 1340-1350, 2019 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-30863899

RESUMO

BACKGROUND: In cardiac resynchronization therapy (CRT) for patients with congenital heart disease (CHD) and a ventricular morphology other than a systemic left ventricle (LV), we previously proposed pacing sites that are different from those used for a systemic LV. The leads should be placed laterally on opposite sides of both ventricles in patients with short-axis dyssynchrony and a single ventricular physiology with two ventricles, whereas they should be placed at the farthest sites along the longitudinal direction in the right ventricle (RV) in patients with long-axis dyssynchrony of the RV. Moreover, in patients with interventricular dyssynchrony and a biventricular physiology with a systemic RV, they should be placed at sites that both ventricles can contract simultaneously. We retrospectively investigated 27 consecutive procedures in 24 patients with CHD who underwent CRT to evaluate the effectiveness of a new ventricular morphology-based CRT strategy. The responder rate was 63% (17/27). The reasons for a non-response to CRT in 10 cases were as follows: non-optimal lead positions during CRT, 4; no systemic ventricular conduction delay or heart failure symptoms before the CRT, 5; short follow-up periods after the CRT, 2; and an extremely dilated systemic RV, 1. The responder rate became 88% (14/16), after excluding the procedures without a ventricular conduction delay or heart failure symptoms and those with non-optimal lead positions. This new strategy for CRT can provide favorable results for CHD patients with a systemic ventricular conduction delay and heart failure.


Assuntos
Dispositivos de Terapia de Ressincronização Cardíaca , Terapia de Ressincronização Cardíaca , Cardiopatias Congênitas/complicações , Insuficiência Cardíaca/terapia , Função Ventricular Direita , Adolescente , Adulto , Criança , Pré-Escolar , Ecocardiografia , Feminino , Cardiopatias Congênitas/cirurgia , Insuficiência Cardíaca/diagnóstico por imagem , Insuficiência Cardíaca/etiologia , Humanos , Lactente , Japão , Masculino , Pessoa de Meia-Idade , Seleção de Pacientes , Recuperação de Função Fisiológica , Estudos Retrospectivos , Resultado do Tratamento , Função Ventricular Esquerda , Adulto Jovem
14.
Artigo em Japonês | MEDLINE | ID: mdl-31548465

RESUMO

OBJECTIVES: The aim of this study was to evaluate an influence of post-processing scatter correction in portable abdominal radiography using a low ratio anti-scatter grid (grid). METHODS: To assess tube voltage on portable abdominal radiography, a burger phantom was used to measure for inverse of image quality figure (IQFinv). For evaluation of the influence on using or not the grid, IQFinv were measured. Abdominal phantom radiographies were assessed subjectively, in random order, by six radiologic technologists. The radiographies were performed without scatter correction [IG (-)] and with scatter correction at equivalent for grid ratio 6 [IG (6)] and 8 [IG (8)]. RESULTS: There was no significant decrease in IQFinv with 75 and 80 kV in comparison of 70 kV. Even processing scatter correction, IQFinv with using the grid was significantly higher than that without using the grid. The ability to detect nasogastric tube and stomach gas were significantly better in the scatter correction. Deviation index for IG (6) and IG (8) were significantly lower than that of IG (-). DISCUSSION: Portable abdominal radiographies will be improved image quality by utilizing scatter correction, although, it is necessary to consider the scatter correction processing as this may significant decrease deviation index in the practical situation. CONCLUSION: The post-processing scatter correction should be useful for detection nasogastric tube and stomach gas in portable abdominal radiography.


Assuntos
Intensificação de Imagem Radiográfica , Radiografia Abdominal , Humanos , Imagens de Fantasmas , Radiografia Abdominal/métodos , Radiografia Torácica , Distribuição Aleatória , Espalhamento de Radiação
15.
Circ J ; 82(2): 403-408, 2018 01 25.
Artigo em Inglês | MEDLINE | ID: mdl-28904256

RESUMO

BACKGROUND: Current surgical outcomes of congenital heart surgery for patients with Down syndrome are unclear.Methods and Results:Of 29,087 operations between 2008 and 2012 registered in the Japan Congenital Cardiovascular Surgery Database (JCCVSD), 2,651 were carried out for patients with Down syndrome (9%). Of those, 5 major biventricular repair procedures [ventricular septal defect repair (n=752), atrioventricular septal defect repair (n=452), patent ductus arteriosus closure (n=184), atrial septal defect repair (n=167), tetralogy of Fallot (TOF) repair (n=108)], as well as 2 major single ventricular palliations [bidirectional Glenn (n=21) and Fontan operation (n=25)] were selected and their outcomes were compared. The 90-day and in-hospital mortality rates for all 5 major biventricular repair procedures and bidirectional Glenn were similarly low in patients with Down syndrome compared with patients without Down syndrome. On the other hand, mortality after Fontan operation in patients with Down syndrome was significantly higher than in patients without Down syndrome (42/1,558=2.7% vs. 3/25=12.0%, P=0.005). CONCLUSIONS: Although intensive management of pulmonary hypertension is essential, analysis of the JCCVSD revealed favorable early prognostic outcomes after 5 major biventricular procedures and bidirectional Glenn in patients with Down syndrome. Indication of the Fontan operation for patients with Down syndrome should be carefully decided.


Assuntos
Procedimentos Cirúrgicos Cardíacos , Síndrome de Down/cirurgia , Cardiopatias/cirurgia , Criança , Bases de Dados Factuais , Síndrome de Down/complicações , Feminino , Cardiopatias Congênitas/cirurgia , Cardiopatias/congênito , Ventrículos do Coração/cirurgia , Mortalidade Hospitalar , Humanos , Lactente , Japão , Masculino , Prognóstico , Resultado do Tratamento
16.
Pediatr Cardiol ; 39(5): 1001-1008, 2018 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-29523921

RESUMO

The purpose of the study is to analyze the impact of hybrid stage 1 palliation on right ventricular myocardial pathology in hypoplastic left heart syndrome. Sufficient amount of right ventricular biopsies could be obtained from 16 of 32 patients who underwent Norwood operation between 2007 and 2013. Histopathological findings of right ventricle in patients who underwent primary Norwood operation (primary group, n = 5), patients with aortic atresia (HS1P AA group, n = 6) or aortic stenosis (HS1P AS group, n = 5) who underwent staged Norwood palliation following hybrid stage 1 palliation were compared. To eliminate the influence of right ventricular pressure afterload, right ventricular biopsies were obtained from patients with truncus arteriosus communis (TAC group, n = 6) at total correction. The percentage of myocardial fibrosis was significantly higher in both HS1P groups than in TAC group; moreover, it was significantly higher in HS1P AA group than in primary group. Capillary vascular density was significantly lower in all hypoplastic left heart syndrome groups than in TAC group. At the sub-endocardial layer, collagen type I/III ratios were higher in HS1P AA group than in other hypoplastic left heart syndrome groups. The proportions of N-cadherin immunolocalized to myocyte termini were lower in all hypoplastic left heart syndrome groups than in TAC group. Right ventricle in hypoplastic left heart syndrome showed more significant ischemic change and myocardial immaturity than that in truncus arteriosus communis. Hybrid stage 1 palliation for aortic atresia would be a risk factor for further right ventricular myocardial ischemia.


Assuntos
Ventrículos do Coração/patologia , Síndrome do Coração Esquerdo Hipoplásico/cirurgia , Miocárdio/patologia , Procedimentos de Norwood/métodos , Estenose da Valva Aórtica/patologia , Estenose da Valva Aórtica/cirurgia , Feminino , Ventrículos do Coração/metabolismo , Humanos , Síndrome do Coração Esquerdo Hipoplásico/patologia , Lactente , Recém-Nascido , Masculino , Miocárdio/metabolismo , Cuidados Paliativos/métodos , Resultado do Tratamento
17.
Am Heart J ; 189: 9-18, 2017 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-28625386

RESUMO

BACKGROUND: Elevated central venous pressure (CVP), low cardiac output, and mild hypoxia are common early and late after Fontan operations. However, the association of these characteristics with late mortality is unclear. We aimed to elucidate the hemodynamic determinants of mortality after Fontan operation. METHOD: We evaluated early (group early; 0.5-5years postoperatively, n=387) and late (group late; ≥15years postoperatively, n=161) Fontan hemodynamics that included CVP (mm Hg), cardiac index (CI; L/min per m2), systemic ventricular end-diastolic volume index (mL/m2), ejection fraction (EF; %), and arterial blood oxygen saturation (%). We examined the effect of these variables on 5-year all-cause mortality. RESULTS: Mortality was higher in group late than in group early (17 vs 11, P<.0001). In both groups, higher CVP (hazard ratio [HR]1.46 and 1.38, respectively; P<.001-.0001) and lower arterial blood oxygen saturation (HR 1.12, P<.001 for both) were associated with increased mortality. Greater end-diastolic volume index (HR per 20: 1.73) and lower EF (HR per 10%: 3.38) were associated with increased mortality only in group early (P<.0001 for both). In contrast, only in group late was higher CI associated with increased mortality (HR 2.50, 95% CI 1.30-4.55, P<.01). Seven patients in group late with both high CVP (≥14) and CI (≥3.0) had the highest mortality (HR 18.1, 5.55-52.4, P<.0001). CONCLUSIONS: Elevated CVP and low arterial blood oxygen saturation correlate with mortality in both early and late Fontan survivors. End-diastolic volume index and EF are associated with mortality only in the earlier cohort, whereas interestingly, elevated cardiac output is associated with increased mortality in the later cohort.


Assuntos
Técnica de Fontan , Cardiopatias Congênitas/cirurgia , Hemodinâmica/fisiologia , Medição de Risco , Adolescente , Fatores Etários , Criança , Pré-Escolar , Feminino , Seguimentos , Cardiopatias Congênitas/mortalidade , Cardiopatias Congênitas/fisiopatologia , Humanos , Lactente , Japão/epidemiologia , Masculino , Estudos Retrospectivos , Fatores de Risco , Taxa de Sobrevida/tendências , Adulto Jovem
19.
Heart Vessels ; 32(2): 234-239, 2017 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-27385023

RESUMO

We describe of a unique pattern of cardiac dyssynchrony in a patient with a biventricular physiology and systemic right ventricle (RV): the interventricular dyssynchrony due to a contraction delay between the left ventricle and RV. In the present case, the cineangiography and intracardiac electrocardiography of the RV did not reveal intraventricular dyssynchrony of the RV, but revealed interventricular dyssynchrony. In addition, the pressure curves of the ventricles exhibited time phase differences between the two ventricles. The cardiac resynchronization therapy determining the pacing lead positions based on the idea of interventricular dyssynchrony induced reverse cardiac remodeling in this patient with systemic RV dysfunction.


Assuntos
Terapia de Ressincronização Cardíaca/métodos , Ventrículos do Coração/fisiopatologia , Disfunção Ventricular Direita/terapia , Adulto , Eletrocardiografia , Humanos , Masculino , Volume Sistólico , Resultado do Tratamento
20.
Nihon Hoshasen Gijutsu Gakkai Zasshi ; 73(12): 1197-1206, 2017.
Artigo em Japonês | MEDLINE | ID: mdl-29269614

RESUMO

PURPOSE: We conducted a field survey about pediatric nuclear medicine. As a result, it was suggested that 99mTc-DMSA scintigraphy was performed at many institutions, whereas various examinations such as image acquisition and processing are not carried out using the renal phantom. Therefore, we developed the body phantom for the evaluation of appropriate administered radioactivities and image quality with renal scintigraphy in pediatric nuclear medicine. METHODS: We created three differently sized body phantoms (1-, 5-, and 20-year-old models). These pediatric body phantoms were filled with a 99mTc solution based on the consensus guideline of pediatric radiopharmaceutical administered radioactivity in Japan. The planar image was evaluated using acquisition count, uniformity and defect contrast. SPECT images were evaluated with a recovery coefficient (RC). RESULTS: The acquisition counts for pediatric body phantoms were relatively corresponded to the clinical study. The appropriate acquisition counts and the pixel size for the planar image were approximately 140 counts per pixel and 1.23-1.35 mm at 5 min acquisition times in 1- and 5-year-old pediatric body phantom studies, respectively. Although the uniformity and the cold contrast did not depend on pixel size and body size, the cold contrast was affected by body size. The RC for SPECT images depended on the performance of SPECT systems, the resolution recovery algorithm and body phantom size. CONCLUSION: The developed pediatric body phantom could allow us to establish optimal image acquisition and more evidence on renal scintigraphy in pediatric nuclear medicine.


Assuntos
Imagens de Fantasmas , Cintilografia , Succímero/uso terapêutico , Criança , Humanos , Medicina Nuclear/métodos , Radioatividade , Succímero/análise , Tecnécio
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA