Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 35
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
Catheter Cardiovasc Interv ; 99(3): 889-895, 2022 02.
Artigo em Inglês | MEDLINE | ID: mdl-34390296

RESUMO

OBJECTIVES: We aimed to describe hemodynamic performance and clinical outcomes at 30-day follow-up of the balloon-expandable (BE) Myval transcatheter heart valve (THV) in low-risk patients. BACKGROUND: The results of the next-generation BE Myval THV in low-risk aortic stenosis (AS) patients are still unknown. METHODS: Retrospective registry performed in nine European centers including patients with low predicted operative mortality risk according to Society of thoracic surgeons (STS) and European system for cardiac operative risk evaluation (EuroSCORE-II) scores. RESULTS: Between September 2019 and February 2021, a total of 100 patients (51% males, mean age 80 ± 6.5 years) were included. Mean STS score and EuroSCORE-II were 2.4 ± 0.8% and 2.2 ± 0.7%, respectively. Intermediate sizes were used in 39% (21.5 mm: 8%, 24.5 mm: 15%, 27.5 mm: 15%). There were no cases of valve embolization, coronary artery occlusion, annulus rupture, or procedural death. A definitive pacemaker implantation was needed in eight patients (8%). At 30-day follow-up aortic valve area (0.7 ± 0.2 vs. 2.1 ± 0.6 cm2 ) and mean aortic valve gradient (43.4 ± 11.1 vs. 9.0 ± 3.7 mmHg) improved significantly (p < 0.001). Moderate aortic regurgitation occurred in 4%. Endpoints of early safety and clinical efficacy were 3 and 1%, respectively. CONCLUSIONS: Hemodynamic performance and 30-day clinical outcomes of the BE Myval THV in low-risk AS patients were favorable. Longer-term follow-up is warranted.


Assuntos
Estenose da Valva Aórtica , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Idoso , Idoso de 80 Anos ou mais , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/etiologia , Estenose da Valva Aórtica/cirurgia , Feminino , Humanos , Masculino , Desenho de Prótese , Estudos Retrospectivos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/métodos , Resultado do Tratamento
2.
J Interv Cardiol ; 2022: 3139476, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36320718

RESUMO

Objective: In TAVR, area sizing is used for balloon-expandable (BE) valves, whereas self-expanding valves are sized to annulus perimeter. For BE valves, this seems illogical: these frames force a circular shape even on an ellipsoid annulus. This can potentially lead to relative undersizing when area sizing is being applied. We developed a perimeter-based sizing algorithm to evaluate the safety and feasibility of perimeter sizing for the Myval BE valve. Methods: In this prospective single-center study, 60 patients with severe aortic stenosis treated with the Myval BE valve were included. Perimeter sizing was used with limited oversizing of 3.7% ± 1.3% compared to the annulus perimeter. After TAVR, clinical outcomes were evaluated at 30 days and 1 year. An echocardiographic follow-up took place at 30 days. Results: At 30 days, the need for PPI and stroke occurred in 2% and 3% of the patients, respectively. Moreover, cardiac death and moderate-severe PVL were absent. At 1-year, cardiac death and stroke were observed in 3% and 8% of the patients, respectively. In 33.3% of the patients, a larger valve size was implanted compared to the valve size calculated by area sizing. Conclusions: Perimeter sizing with the Myval BE valve leads to substantial use of larger valve sizes and favorable clinical outcomes, with low PPI and the absence of significant PVL. A randomized controlled trial is being planned to prove the superiority of this alternative sizing method.


Assuntos
Estenose da Valva Aórtica , Bioprótese , Próteses Valvulares Cardíacas , Acidente Vascular Cerebral , Substituição da Valva Aórtica Transcateter , Humanos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Estenose da Valva Aórtica/cirurgia , Valva Aórtica/cirurgia , Projetos Piloto , Estudos Prospectivos , Tomografia Computadorizada Multidetectores/métodos , Acidente Vascular Cerebral/etiologia , Morte , Desenho de Prótese , Resultado do Tratamento
3.
J Interv Cardiol ; 2022: 6858962, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36128073

RESUMO

Objectives: To determine the incidence of upper extremity dysfunction (UED), after a transradial percutaneous coronary intervention (TR-PCI). Background: Transradial approach (TRA) is the preferred approach for coronary interventions. However, upper extremity complications may be underreported. Methods: The ARCUS was designed as a prospective cohort study, including 502 consecutive patients admitted for PCI. Patients treated with transfemoral PCI (TF-PCI) acted as a control group. A composite score of physical examinations and questionnaires was used for determining UED. Clinical outcomes were monitored during six months of follow-up, with its primary endpoint at two weeks. Results: A total of 440 TR-PCI and 62 control patients were included. Complete case analysis (n = 330) at 2 weeks of follow-up showed that UED in the TR-PCI group was significantly higher than that in the TF-PCI group: 32.7% versus 13.9%, respectively (p=0.04). The three impaired variables most contributing to UED were impaired elbow extension, wrist flexion, and extension. Multivariate logistic regression showed that smokers were almost three times more likely to develop UED. Conclusions: This study demonstrates that UED seems to occur two times more in TR-PCI than in TF-PCI at 2 weeks of follow-up. However, no significant long-term difference or difference between the intervention arm and the contralateral arm was found at all timepoints.


Assuntos
Intervenção Coronária Percutânea , Artéria Femoral , Humanos , Intervenção Coronária Percutânea/efeitos adversos , Intervenção Coronária Percutânea/métodos , Estudos Prospectivos , Artéria Radial , Resultado do Tratamento , Extremidade Superior
4.
Eur Heart J ; 42(45): 4671-4679, 2021 12 01.
Artigo em Inglês | MEDLINE | ID: mdl-34345911

RESUMO

AIMS: The aim of this study was to understand the impact of optical coherence tomography (OCT)-detected thin-cap fibroatheroma (TCFA) on clinical outcomes of diabetes mellitus (DM) patients with fractional flow reserve (FFR)-negative lesions. METHODS AND RESULTS: COMBINE OCT-FFR study was a prospective, double-blind, international, natural history study. After FFR assessment, and revascularization of FFR-positive lesions, patients with ≥1 FFR-negative lesions (target lesions) were classified in two groups based on the presence or absence of ≥1 TCFA lesion. The primary endpoint compared FFR-negative TCFA-positive patients with FFR-negative TCFA-negative patients for a composite of cardiac mortality, target vessel myocardial infarction, clinically driven target lesion revascularization or unstable angina requiring hospitalization at 18 months. Among 550 patients enrolled, 390 (81%) patients had ≥1 FFR-negative lesions. Among FFR-negative patients, 98 (25%) were TCFA positive and 292 (75%) were TCFA negative. The incidence of the primary endpoint was 13.3% and 3.1% in TCFA-positive vs. TCFA-negative groups, respectively (hazard ratio 4.65; 95% confidence interval, 1.99-10.89; P < 0.001). The Cox regression multivariable analysis identified TCFA as the strongest predictor of major adverse clinical events (MACE) (hazard ratio 5.12; 95% confidence interval 2.12-12.34; P < 0.001). CONCLUSIONS: Among DM patients with ≥1 FFR-negative lesions, TCFA-positive patients represented 25% of this population and were associated with a five-fold higher rate of MACE despite the absence of ischaemia. This discrepancy between the impact of vulnerable plaque and ischaemia on future adverse events may represent a paradigm shift for coronary artery disease risk stratification in DM patients.


Assuntos
Doença da Artéria Coronariana , Diabetes Mellitus , Reserva Fracionada de Fluxo Miocárdico , Placa Aterosclerótica , Angiografia Coronária , Doença da Artéria Coronariana/diagnóstico por imagem , Vasos Coronários/diagnóstico por imagem , Humanos , Placa Aterosclerótica/diagnóstico por imagem , Valor Preditivo dos Testes , Estudos Prospectivos , Tomografia de Coerência Óptica
5.
N Engl J Med ; 376(24): 2319-2328, 2017 06 15.
Artigo em Inglês | MEDLINE | ID: mdl-28402237

RESUMO

BACKGROUND: Bioresorbable vascular scaffolds were developed to overcome the shortcomings of drug-eluting stents in percutaneous coronary intervention (PCI). We performed an investigator-initiated, randomized trial to compare an everolimus-eluting bioresorbable scaffold with an everolimus-eluting metallic stent in the context of routine clinical practice. METHODS: We randomly assigned 1845 patients undergoing PCI to receive either a bioresorbable vascular scaffold (924 patients) or a metallic stent (921 patients). The primary end point was target-vessel failure (a composite of cardiac death, target-vessel myocardial infarction, or target-vessel revascularization). The data and safety monitoring board recommended early reporting of the study results because of safety concerns. This report provides descriptive information on end-point events. RESULTS: The median follow-up was 707 days. Target-vessel failure occurred in 105 patients in the scaffold group and in 94 patients in the stent group (2-year cumulative event rates, 11.7% and 10.7%, respectively; hazard ratio, 1.12; 95% confidence interval [CI], 0.85 to 1.48; P=0.43); event rates were based on Kaplan-Meier estimates in time-to-event analyses. Cardiac death occurred in 18 patients in the scaffold group and in 23 patients in the stent group (2-year cumulative event rates, 2.0% and 2.7%, respectively), target-vessel myocardial infarction occurred in 48 patients in the scaffold group and in 30 patients in the stent group (2-year cumulative event rates, 5.5% and 3.2%), and target-vessel revascularization occurred in 76 patients in the scaffold group and in 65 patients in the stent group (2-year cumulative event rates, 8.7% and 7.5%). Definite or probable device thrombosis occurred in 31 patients in the scaffold group as compared with 8 patients in the stent group (2-year cumulative event rates, 3.5% vs. 0.9%; hazard ratio, 3.87; 95% CI, 1.78 to 8.42; P<0.001). CONCLUSIONS: In this preliminary report of a trial involving patients undergoing PCI, there was no significant difference in the rate of target-vessel failure between the patients who received a bioresorbable scaffold and the patients who received a metallic stent. The bioresorbable scaffold was associated with a higher incidence of device thrombosis than the metallic stent through 2 years of follow-up. (Funded by Abbott Vascular; AIDA ClinicalTrials.gov number, NCT01858077 .).


Assuntos
Implantes Absorvíveis , Estenose Coronária/terapia , Stents Farmacológicos , Intervenção Coronária Percutânea , Stents Metálicos Autoexpansíveis , Implantes Absorvíveis/efeitos adversos , Idoso , Everolimo/administração & dosagem , Feminino , Seguimentos , Cardiopatias/mortalidade , Humanos , Incidência , Estimativa de Kaplan-Meier , Masculino , Pessoa de Meia-Idade , Infarto do Miocárdio/etiologia , Stents Metálicos Autoexpansíveis/efeitos adversos , Trombose/epidemiologia , Trombose/etiologia , Resultado do Tratamento
6.
Cardiovasc Diabetol ; 15(1): 144, 2016 10 10.
Artigo em Inglês | MEDLINE | ID: mdl-27724869

RESUMO

BACKGROUND: Fractional flow reserve (FFR) is a widely used tool for the identification of ischaemia-generating stenoses and to guide decisions on coronary revascularisation. However, the safety of FFR-based decisions in high-risk subsets, such as patients with Diabetes Mellitus (DM) or vulnerable stenoses presenting thin-cap fibro-atheroma (TCFA), is unknown. This study will examine the impact of optical coherence tomography (OCT) plaque morphological assessment and the identification of TCFA, in combination with FFR to better predict clinical outcomes in DM patients. METHODS: COMBINE (OCT-FFR) is a prospective, multi-centre study investigating the natural history of DM patients with ≥1 angiographically intermediate target lesion in three subgroups of patients; patients with FFR negative lesions without TCFA (group A) and patients with FFR negative lesions with TCFA (group B) as detected by OCT and to compare these two groups with each other, as well as to a third group with FFR-positive, PCI-treated intermediate lesions (group C). The study hypothesis is that DM patients with TCFA (group B) have a worse outcome than those without TCFA (group A) and also when compared to those patients with lesions FFR ≤0.80 who underwent complete revascularisation. The primary endpoint is the incidence of target lesion major adverse cardiac events (MACE); a composite of cardiac death, myocardial infarction or rehospitalisation for unstable/progressive angina in group B vs. group A. CONCLUSION: COMBINE (OCT-FFR) is the first prospective study to examine whether the addition of OCT plaque morphological evaluation to FFR haemodynamic assessment of intermediate lesions in DM patients will better predict MACE and possibly lead to new revascularisation strategies. Trial Registration Netherlands Trial Register: NTR5376.


Assuntos
Cateterismo Cardíaco , Doença da Artéria Coronariana/diagnóstico , Estenose Coronária/diagnóstico , Vasos Coronários/diagnóstico por imagem , Vasos Coronários/fisiopatologia , Angiopatias Diabéticas/diagnóstico , Reserva Fracionada de Fluxo Miocárdico , Hemodinâmica , Tomografia de Coerência Óptica , Protocolos Clínicos , Angiografia Coronária , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/fisiopatologia , Doença da Artéria Coronariana/terapia , Estenose Coronária/diagnóstico por imagem , Estenose Coronária/fisiopatologia , Estenose Coronária/terapia , Angiopatias Diabéticas/diagnóstico por imagem , Angiopatias Diabéticas/fisiopatologia , Angiopatias Diabéticas/terapia , Progressão da Doença , Europa (Continente) , Humanos , Intervenção Coronária Percutânea , Placa Aterosclerótica , Valor Preditivo dos Testes , Estudos Prospectivos , Projetos de Pesquisa , Índice de Gravidade de Doença , Fatores de Tempo , Resultado do Tratamento
7.
Catheter Cardiovasc Interv ; 88(7): 1036-1043, 2016 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-27037641

RESUMO

OBJECTIVE: The aim of this study is to provide a complete insight in the access-site morbidity and upper extremity function after Transradial Percutaneous Coronary Intervention (TR-PCI). BACKGROUND: In percutaneous coronary intervention the Transradial Approach (TRA) is gaining popularity as a default technique. It is a very promising technique with respect to post-procedure complications, but the exact effects of TRA on upper extremity function are unknown. METHODS AND RESULTS: The effects of trAnsRadial perCUtaneouS coronary intervention on upper extremity function (ARCUS) trial is a multicenter prospective cohort study that will be conducted in all patients admitted for TR-PCI. Clinical outcomes will be monitored during a follow-up of 6 months, with its primary endpoint at two weeks of follow-up. To investigate the complete upper extremity function, a combination of physical examinations and validated questionnaires will be used to provide information on anatomical integrity, strength, range of motion (ROM), coordination, sensibility, pain, and functioning in everyday life. Procedural and material specifications will be registered in order to include all possible aspects influencing upper extremity function. CONCLUSIONS: Results from this study will elucidate the effect of TR-PCI on upper extremity function. This creates the opportunity to further optimize TR-PCI, to make improvements in functional outcome and to prevent morbidity regarding full upper extremity function. © 2016 Wiley Periodicals, Inc.


Assuntos
Cateterismo Periférico/métodos , Doença da Artéria Coronariana/terapia , Intervenção Coronária Percutânea/métodos , Artéria Radial , Extremidade Superior/irrigação sanguínea , Extremidade Superior/fisiopatologia , Atividades Cotidianas , Fenômenos Biomecânicos , Cateterismo Periférico/efeitos adversos , Protocolos Clínicos , Doença da Artéria Coronariana/diagnóstico por imagem , Humanos , Força Muscular , Países Baixos , Dor/etiologia , Intervenção Coronária Percutânea/efeitos adversos , Intervenção Coronária Percutânea/instrumentação , Exame Físico , Estudos Prospectivos , Punções , Artéria Radial/diagnóstico por imagem , Amplitude de Movimento Articular , Projetos de Pesquisa , Stents , Inquéritos e Questionários , Fatores de Tempo , Resultado do Tratamento
8.
Eur Heart J Qual Care Clin Outcomes ; 9(4): 417-426, 2023 06 21.
Artigo em Inglês | MEDLINE | ID: mdl-35876646

RESUMO

BACKGROUND: Multisite artery disease is considered a 'malignant' type of atherosclerotic disease associated with an increased cardiovascular risk, but the impact of multisite artery disease on clinical outcomes after percutaneous coronary intervention (PCI) is unknown. METHODS: Patients enrolled in the large, prospective e-Ultimaster study were grouped into (1) those without known prior vascular disease, (2) those with known single-territory vascular disease, and (3) those with known two to three territories (i.e coronary, cerebrovascular, or peripheral) vascular disease (multisite artery disease). The primary outcome was coronary target lesion failure (TLF), defined as the composite of cardiac death, target vessel-related myocardial infarction, and clinically driven target lesion revascularization at 1-year. Inverse propensity score weighted (IPSW) analysis was performed to address differences in baseline patient and lesion characteristics. RESULTS: Of the 37 198 patients included in the study, 62.3% had no prior known vascular disease, 32.6% had single-territory vascular disease, and 5.1% had multisite artery disease. Patients with known vascular disease were older and were more likely to be men and to have more co-morbidities. After IPSW, the TLF rate incrementally increased with the number of diseased vascular beds (3.16%, 4.44%, and 6.42% for no, single, and multisite artery disease, respectively, P < 0.01 for all comparisons). This was also true for all-cause death (2.22%, 3.28%, and 5.29%, P < 0.01 for all comparisons) and cardiac mortality (1.26%, 1.91%, and 3.62%, P ≤ 0.01 for all comparisons). CONCLUSIONS: Patients with previously known vascular disease experienced an increased risk of adverse cardiovascular events and mortality post-PCI. This risk is highest among patients with multisite artery disease.Trial Registration: URL: https://www.clinicaltrials.gov. Unique identifier: NCT02188355.


Assuntos
Doença da Artéria Coronariana , Stents Farmacológicos , Intervenção Coronária Percutânea , Masculino , Humanos , Feminino , Intervenção Coronária Percutânea/efeitos adversos , Estudos Prospectivos , Fatores de Risco , Resultado do Tratamento , Sistema de Registros , Artérias
9.
Eur Heart J Cardiovasc Imaging ; 24(5): 687-693, 2023 04 24.
Artigo em Inglês | MEDLINE | ID: mdl-36342269

RESUMO

AIMS: To study if any qualitative or quantitative optical coherence tomography (OCT) variables in combination with thin cap fibroatheroma (TCFA) patients could improve the identification of lesions at risk for future major adverse cardiac events (MACEs). METHODS AND RESULTS: From the combined optical coherence tomography morphologic and fractional flow reserve hemodynamic assessment of non- culprit lesions to better predict adverse event outcomes in diabetes mellitus patients: COMBINE (OCT-FFR) trial database (NCT02989740), we performed a detailed assessment OCT qualitative and quantitative variables in TCFA carrying diabetes mellitus (DM) patients with vs. without MACE during follow-up. MACEs were defined as a composite of cardiac death, target vessel myocardial infarction, clinically driven target lesion revascularization, and hospitalization for unstable angina. From the 390 fractional flow reserve (FFR)-negative DM patients, 98 (25.2%) had ≥1 OCT-detected TCFA, of which 13 (13.3%) had MACE and 85 (86.7%) were event-free (non-MACE). The baseline characteristics were similar between both groups; however, a smaller minimal lumen area (MLA) and lower mean FFR value were observed in MACE group (1.80 vs. 2.50 mm2, P = 0.01, and 0.85 vs. 0.89, P = 0.02, respectively). Prevalence of healed plaque (HP) was higher in the MACE group (53.85 vs. 21.18%, P = 0.01). TCFA were predominantly located proximal to the MLA. TCFA area was smaller in the MACE group, while no difference was observed regarding the lesion area. CONCLUSION: Within TCFA carrying patients, a smaller MLA, lower FFR values, and TCFA location adjacent to a HP were associated with future MACE. Carpet-like measured lesion area surface was similar, while the TCFA area was smaller in the MACE arm, and predominantly located proximal to the MLA.


Assuntos
Doença da Artéria Coronariana , Reserva Fracionada de Fluxo Miocárdico , Infarto do Miocárdio , Placa Aterosclerótica , Humanos , Placa Aterosclerótica/patologia , Tomografia de Coerência Óptica/métodos , Angina Instável , Vasos Coronários/patologia , Doença da Artéria Coronariana/patologia , Valor Preditivo dos Testes , Angiografia Coronária
10.
Rev Esp Cardiol (Engl Ed) ; 76(11): 872-880, 2023 Nov.
Artigo em Inglês, Espanhol | MEDLINE | ID: mdl-36898524

RESUMO

INTRODUCTION AND OBJECTIVES: No comparisons have been published yet regarding the newest iteration of balloon- and self-expandable transcatheter heart valves for the treatment of bicuspid aortic valve (BAV) stenosis. METHODS: Multicenter registry of consecutive patients with severe BAV stenosis treated with balloon-expandable transcatheter heart valves (Myval and SAPIEN 3 Ultra, S3U) or self-expanding Evolut PRO+(EP+). TriMatch analysis was carried out to minimize the impact of baseline differences. The primary endpoint of the study was 30-day device success, and the secondary endpoints were the composite and individual components of early safety at 30 days. RESULTS: A total of 360 patients (age 76.6±7.6 years, 71.9% males) were included: 122 Myval (33.9%), 129 S3U (35.8%), and 109 EP+(30.3%). The mean STS score was 3.6±1.9%. There were no cases of coronary artery occlusion, annulus rupture, aortic dissection, or procedural death. The primary endpoint of device success at 30 days was significantly higher in the Myval group (Myval: 100%; S3U: 87.5%; and EP+: 81.3%), mainly due to higher residual aortic gradients with S3U and greater≥moderate aortic regurgitation (AR) with EP+. No significant differences were found in the unadjusted rate of pacemaker implantation. CONCLUSIONS: In patients with BAV stenosis deemed unsuitable for surgery, Myval, S3U and EP+showed similar safety but balloon-expandable Myval had better gradients than S3U, and both balloon-expandable devices had lower residual AR than EP+, suggesting that, taking into consideration the patient-specific risks, any of these devices can be selected with optimal outcomes.


Assuntos
Estenose da Valva Aórtica , Doença da Válvula Aórtica Bicúspide , Doenças das Valvas Cardíacas , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Masculino , Humanos , Idoso , Idoso de 80 Anos ou mais , Feminino , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Constrição Patológica , Resultado do Tratamento , Estenose da Valva Aórtica/diagnóstico , Estenose da Valva Aórtica/cirurgia , Doenças das Valvas Cardíacas/complicações , Doenças das Valvas Cardíacas/cirurgia , Doença da Válvula Aórtica Bicúspide/cirurgia , Desenho de Prótese
11.
EuroIntervention ; 19(9): 766-771, 2023 Nov 17.
Artigo em Inglês | MEDLINE | ID: mdl-37605804

RESUMO

About one-third of patients undergoing transcatheter aortic valve implantation (TAVI) use oral anticoagulants (OAC), mainly due to atrial fibrillation. General guidelines advise interrupting OAC in patients with a high risk of bleeding undergoing interventions. However, preliminary observational data suggest that the continuation of OAC during TAVI is safe and may reduce the risk of periprocedural thromboembolic events. The Periprocedural Continuation Versus Interruption of Oral Anticoagulant Drugs During Transcatheter Aortic Valve Implantation (POPular PAUSE TAVI) is a multicentre, randomised clinical trial with open-label treatment and blinded endpoint assessment. Patients are randomised 1:1 to periprocedural continuation versus interruption of OAC and are stratified for vitamin K antagonist or direct oral anticoagulant use. The primary endpoint is a composite of cardiovascular mortality, all stroke, myocardial infarction, major vascular complications and type 2-4 bleeding within 30 days after TAVI, according to the Valve Academic Research Consortium-3 criteria. Secondary endpoints include separate individual and composite outcomes, quality of life and cost-effectiveness. Since continuation of OAC is associated with the ancillary benefit that it simplifies periprocedural management, the primary outcome is first analysed for non-inferiority; if non-inferiority is proven, superiority will be tested. Recruitment started in November 2020, and the trial will continue until a total of 858 patients have been included and followed for 90 days. In summary, POPular PAUSE TAVI is the first randomised clinical trial to assess the safety and efficacy of periprocedural continuation versus interruption of OAC in patients undergoing TAVI.


Assuntos
Estenose da Valva Aórtica , Substituição da Valva Aórtica Transcateter , Humanos , Qualidade de Vida , Anticoagulantes/uso terapêutico , Hemorragia , Resultado do Tratamento , Valva Aórtica/cirurgia , Fatores de Risco
12.
Catheter Cardiovasc Interv ; 79(6): 870-7, 2012 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-21735533

RESUMO

BACKGROUND: Although current clinical guidelines recommend the use of thrombus aspiration (TA) during primary percutaneous coronary intervention (PPCI), previous studies evaluating TA demonstrated contradictory results. The aim of this study was to evaluate long-term clinical outcome after TA in adjunct to PPCI for acute ST-segment myocardial infarction (STEMI), as compared with conventional treatment, with the use of paclitaxel-eluting stents or bare-metal stents. METHODS: We analyzed data of the PASSION trial, in which 619 patients with STEMI were randomly assigned to a paclitaxel-eluting stent or a bare-metal stent. TA was performed in 311 patients (50.2%). Clinical endpoints at 2 years were compared between patients who received TA during PPCI with patients who underwent conventional PPCI. The primary outcome of interest was a composite of cardiac death, recurrent myocardial infarction (MI), or target-lesion revascularization (TLR). A propensity score model was made to account for baseline differences that could have affected the probability of performing TA. RESULTS: Complete follow-up was available for 598 patients (96.6%). The cumulative incidence of the combined outcome measure of cardiac death, recurrent MI, or TLR was 40 (13.0%) in the TA group and 41 (13.5%) in the conventional PPCI group (HR 0.96; 95% CI 0.62-1.47; P = 0.84). Also after adjusting for propensity score, no significant difference in event rate was observed between both treatment groups. CONCLUSIONS: In this post-hoc analysis of the PASSION trial, TA in adjunct to PPCI did not affect rates of major adverse cardiac events at 2 years follow-up, as compared with conventional PPCI.


Assuntos
Angioplastia Coronária com Balão/instrumentação , Fármacos Cardiovasculares/administração & dosagem , Stents Farmacológicos , Metais , Infarto do Miocárdio/terapia , Paclitaxel/administração & dosagem , Stents , Trombectomia/métodos , Idoso , Angioplastia Coronária com Balão/efeitos adversos , Angioplastia Coronária com Balão/mortalidade , Distribuição de Qui-Quadrado , Angiografia Coronária , Feminino , Humanos , Estimativa de Kaplan-Meier , Modelos Logísticos , Masculino , Pessoa de Meia-Idade , Infarto do Miocárdio/diagnóstico por imagem , Infarto do Miocárdio/mortalidade , Países Baixos , Razão de Chances , Pontuação de Propensão , Modelos de Riscos Proporcionais , Desenho de Prótese , Recidiva , Estudos Retrospectivos , Medição de Risco , Fatores de Risco , Sucção , Trombectomia/efeitos adversos , Trombectomia/mortalidade , Fatores de Tempo , Resultado do Tratamento
13.
Eur Heart J ; 32(12): 1472-8, 2011 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-20051425

RESUMO

Aims Comparison of magnetic guidewire navigation in percutaneous coronary intervention (MPCI) vs. conventional percutaneous coronary intervention (CPCI) for the treatment of acute myocardial infarction. Methods and results We compared 65 sequential patients (mean age 61 ± 15 years) undergoing primary MPCI with those of 405 patients undergoing CPCI (mean age 61 ± 13 years). The major endpoint was contrast media use. Technical success and procedural outcomes were evaluated. Clinical demographics and angiographic characteristics of the two groups were similar, except for fewer patients with previous coronary artery bypass grafting (CABG) and hypertension in the CPCI group and fewer patients with diabetes in the MPCI group. The technical success rate was high in both the MPCI and CPCI groups (95.4 vs. 98%). There was significantly less contrast media usage in the MPCI compared with the CPCI group, median reduction of contrast media of 30 mL with an OR = 0.41 (0.21-0.81). Fluoroscopy times were significantly reduced for MPCI compared with CPCI, median reduction of 7.2 min with an OR = 0.42 (0.20-0.79). Conclusion This comparison indicates the feasibility and non-inferiority of magnetic navigation in performing primary PCI and suggests the possibility of reductions in contrast media use and fluoroscopy time compared with CPCI.


Assuntos
Angioplastia Coronária com Balão/métodos , Magnetismo/métodos , Infarto do Miocárdio/terapia , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Angioplastia Coronária com Balão/instrumentação , Estudos de Casos e Controles , Meios de Contraste , Desenho de Equipamento , Estudos de Viabilidade , Feminino , Fluoroscopia , Humanos , Masculino , Pessoa de Meia-Idade , Resultado do Tratamento
14.
J Invasive Cardiol ; 34(6): E462-E468, 2022 06.
Artigo em Inglês | MEDLINE | ID: mdl-35652709

RESUMO

BACKGROUND: Randomized controlled trials for in-stent restenosis (ISR) and de novo lesions in small-diameter vessels have shown promising results, but data on DCB use in real-world practice are still scarce. The aim of the PEARL (Paclitaxel-Eluting Angioplasty Balloon in the Real-World) registry was to evaluate the safety and efficacy of a paclitaxel DCB in real-world percutaneous coronary intervention (PCI) practice. METHODS: Between 2014 and 2019, a total of 513 patients treated with the Protégé paclitaxel DCB (Wellinq) were prospectively included at 4 hospitals in the Netherlands. The primary endpoint was 2-year major adverse cardiac event (MACE), defined as cardiac death, target-vessel myocardial infarction, or target-lesion revascularization (TLR). RESULTS: DCB was used for ISR in 382 patients and for de novo lesions in 131 patients. Acute coronary syndrome was the reason for presentation in 58.9% of patients. At lesion level, 34.1% of lesions were classified as type B2 and 36.1% as type C. Predilation was performed in 62.2% and noncompliant DCB was used in 40.7% of lesions. DCB-related procedural complications were infrequent (3.3%, mostly coronary dissection [2.3%]). Bailout stenting was required in 3.1%. MACE during 2-year follow-up occurred in 17.1% of patients treated for ISR and 9.7% of patients treated for de novo lesions. The incidence of TLR was 11.7% of ISR patients and 2.9% of de novo patients. History of coronary artery bypass grafting and lesion length were predictors of MACE in patients treated for ISR. CONCLUSION: The use of Protégé paclitaxel DCB for PCI of ISR and de novo lesions is safe and effective during 2-year follow-up.


Assuntos
Angioplastia Coronária com Balão , Doença da Artéria Coronariana , Intervenção Coronária Percutânea , Angioplastia Coronária com Balão/efeitos adversos , Angioplastia Coronária com Balão/métodos , Doença da Artéria Coronariana/diagnóstico , Doença da Artéria Coronariana/etiologia , Doença da Artéria Coronariana/cirurgia , Humanos , Paclitaxel/farmacologia , Intervenção Coronária Percutânea/efeitos adversos , Sistema de Registros , Resultado do Tratamento
15.
Hand (N Y) ; : 15589447211073832, 2022 Mar 04.
Artigo em Inglês | MEDLINE | ID: mdl-35245991

RESUMO

BACKGROUND: The transradial artery access is the benchmark approach in transradial percutaneous coronary intervention (TR-PCI). The purpose of this study was to evaluate the different complications, treatments, and outcome of upper extremity dysfunction following a TR-PCI. METHODS: This was a prospective cohort substudy of patients with access-site complications. The study population consisted of 433 patients treated with TR-PCI. Referral to the hand center was mandated if the patient experienced new-onset or increase of preexistent symptoms in the upper extremity. Patients were followed up to the last control visit (5-7 months after the index procedure) at the hand center. Outcome results were categorized in "symptom-free," "improvement of symptoms," and "no improvement." RESULTS: Forty-one (9% of total) patients underwent assessment at the hand center. Most frequent referral indication was pain in the intervention arm. Women, preexisting sensibility disorder, and osteoarthritis in the intervention arm were associated with increased odds of referral. The most common complications diagnosed were carpal tunnel syndrome (n = 18) and osteoarthritis (n = 15). Thirty patients required further medical treatment. Immobilization therapy was most applied. Seventeen (4% of total) patients had persisting symptoms despite medical treatment. CONCLUSIONS: The occurrence of complications in the upper extremity after a TR-PCI is small. Despite medical treatment, symptoms persisted in 4% of all patients treated with TR-PCI. Possible explanations for the persisting symptoms are exacerbation of latent osteoarthritis and carpal tunnel syndrome by trauma-induced edema. Awareness of TR-PCI-induced complications among all specialists is essential to optimize patient care.

16.
J Am Heart Assoc ; 11(17): e025459, 2022 09 06.
Artigo em Inglês | MEDLINE | ID: mdl-36000428

RESUMO

Background Coronary bifurcation lesions (CBLs) are frequently encountered in clinical practice and are associated with worse outcomes after percutaneous coronary intervention. However, there are limited data around the prognostic impact of different CBL distributions. Methods and Results All CBL percutaneous coronary intervention procedures from the prospective e-Ultimaster (Prospective, Single-Arm, Multi Centre Observations Ultimaster Des Registry) multicenter international registry were analyzed according to CBL distribution as defined by the Medina classification. Cox proportional hazards models were used to compare the hazard ratio (HR) of the primary outcome, 1-year target lesion failure (composite of cardiac death, target vessel-related myocardial infarction, and clinically driven target lesion revascularization), and its individual components between Medina subtypes using Medina 1.0.0 as the reference category. A total of 4003 CBL procedures were included. The most prevalent Medina subtypes were 1.1.1 (35.5%) and 1.1.0 (26.8%), whereas the least prevalent was 0.0.1 (3.5%). Overall, there were no significant differences in patient and procedural characteristics among Medina subtypes. Only Medina 1.1.1 and 0.0.1 subtypes were associated with increased target lesion failure (HR, 2.6 [95% CI, 1.3-5.5] and HR, 4.0 [95% CI, 1.6-9.0], respectively) at 1 year, compared with Medina 1.0.0, prompted by clinically driven target lesion revascularization (HR, 3.1 [95% CI, 1.1-8.6] and HR, 4.6 [95% CI, 1.3-16.0], respectively) as well as cardiac death in Medina 0.0.1 (HR, 4.7 [95% CI, 1.0-21.6]). No differences in secondary outcomes were observed between Medina subtypes. Conclusions In a large multicenter registry analysis of coronary bifurcation percutaneous coronary intervention procedures, we demonstrate prognostic differences in 1-year outcomes between different CBL distributions, with Medina 1.1.1 and 0.0.1 subtypes associated with an increased risk of target lesion failure.


Assuntos
Doença da Artéria Coronariana , Stents Farmacológicos , Intervenção Coronária Percutânea , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/cirurgia , Morte , Humanos , Intervenção Coronária Percutânea/efeitos adversos , Intervenção Coronária Percutânea/métodos , Estudos Prospectivos , Sistema de Registros , Fatores de Risco , Resultado do Tratamento
17.
Clin Cardiol ; 45(12): 1211-1219, 2022 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-36072999

RESUMO

BACKGROUND: Elderly patients with ST-elevation myocardial infarction (STEMI) who undergo percutaneous coronary intervention (PCI) are usually excluded from major trials. HYOPTHESIS: This study sought to assess 1-year clinical outcomes following PCI with a drug-eluting stent in patients older than 80 years old with STEMI. METHODS: The large all-comer, multicontinental e-ULTIMASTER registry included 7507 patients with STEMI who underwent PCI using the Ultimaster stent. The primary clinical endpoint was 1-year target lesion failure, a composite of cardiac death (CD), target vessel-related myocardial infarction (TV-MI), or clinically driven target lesion revascularization (CD-TLR). RESULTS: There were 457 (6.1%) patients in the elderly group (≥80 years old) that were compared to 7050 (93.9%) patients <80 years. The elderly patients included more female patients and had significantly more comorbidities and had more complex coronary anatomy. The primary endpoint occurred in 7.2% of the elderly, compared to 3.1% of the younger group (p < .001). All-cause mortality was significantly higher among the elderly group compared to the younger group (10.1% vs. 2.3%, p < .0001), as well as CD (6.1% vs. 1.6%, p < .0001), but not TV-MI (1.1% vs. 0.7%, p = .34) or CD-TLR (1.1% vs. 1.4%, p = .63). CONCLUSION: Elderly patients with STEMI presentation had a higher incidence of the composite endpoint than younger patients. All-cause and CD were higher for elderly patients compared to patients younger than 80 years old. However, there was no difference in the incidence of TV-MI or target lesion revascularizations. These findings suggest that PCI for STEMI in elderly patients is relatively safe.


Assuntos
Stents Farmacológicos , Infarto do Miocárdio , Intervenção Coronária Percutânea , Infarto do Miocárdio com Supradesnível do Segmento ST , Humanos , Feminino , Idoso , Idoso de 80 Anos ou mais , Intervenção Coronária Percutânea/efeitos adversos , Infarto do Miocárdio com Supradesnível do Segmento ST/diagnóstico , Infarto do Miocárdio com Supradesnível do Segmento ST/cirurgia , Estudos Prospectivos , Resultado do Tratamento , Sistema de Registros , Prognóstico
18.
Circ Cardiovasc Interv ; 15(5): e011728, 2022 05.
Artigo em Inglês | MEDLINE | ID: mdl-35485232

RESUMO

BACKGROUND: Autopsy studies have established that thin-cap fibroatheromas (TCFAs) are the most frequent cause of fatal coronary events. In living patients, optical coherence tomography (OCT) has sufficient resolution to accurately differentiate TCFA from thick-cap fibroatheroma (ThCFA) and not lipid rich plaque (non-LRP). However, the impact of OCT-detected plaque phenotype of nonischemic lesions on future adverse events remains unknown. Therefore, we studied the natural history of OCT-detected TCFA, ThCFA, and non-LRP in patients enrolled in the prospective multicenter COMBINE FFR-OCT trial (Combined Optical Coherence Tomography Morphologic and Fractional Flow Reserve Hemodynamic Assessment of Non-Culprit Lesions to Better Predict Adverse Event Outcomes in Diabetes Mellitus Patients). METHODS: In the COMBINE FFR-OCT trial, patients with diabetes and ≥1 lesion with a fractional flow reserve >0.80 underwent OCT evaluation and were clinically followed for 18 months. A composite primary end point of cardiac death, target vessel-related myocardial infarction, target-lesion revascularization, and hospitalization for unstable angina was evaluated in relation to OCT-based plaque morphology. RESULTS: A total of 390 patients (age 67.5±9 years; 63% male) with ≥1 nonischemic lesions underwent OCT evaluation: 284 (73%) had ≥1 LRP and 106 (27%) non-LRP lesions. Among LRP patients, 98 (34.5%) had ≥1 TCFA. The primary end point occurred in 7% of LRP patients compared with 1.9% of non-LRP patients (7.0% versus 1.9%; hazard ratio [HR], 3.9 [95% CI, 0.9-16.5]; P=0.068; log rank-P=0.049). However, within LRP patients, TCFA patients had a much higher risk for primary end point compared with ThCFA (13.3% versus 3.8%; HR, 3.8 [95% CI, 1.5-9.5]; P<0.01), and to non-LRP patients (13.3% versus 1.9%; HR, 7.7 [95% CI, 1.7-33.9]; P<0.01), whereas ThCFA patients had risk similar to non-LRP patients (3.8% versus 1.9%; HR, 2.0 [95% CI, 0.42-9.7]; P=0.38). Multivariable analyses identified TCFA as the strongest independent predictor of primary end point (HR, 6.79 [95% CI, 1.50-30.72]; P=0.013). CONCLUSIONS: Among diabetes patients with fractional flow reserve-negative lesions, patients carrying TCFA lesions represent only one-third of LRP patients and are associated with a high risk of future events while patients carrying LRP-ThCFA and non-LRP lesions portend benign outcomes. REGISTRATION: URL: https://www. CLINICALTRIALS: gov; Unique identifier: NCT02989740.


Assuntos
Doença da Artéria Coronariana , Diabetes Mellitus , Reserva Fracionada de Fluxo Miocárdico , Placa Aterosclerótica , Idoso , Angiografia Coronária , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/patologia , Doença da Artéria Coronariana/terapia , Vasos Coronários , Diabetes Mellitus/diagnóstico , Feminino , Humanos , Lipídeos , Masculino , Pessoa de Meia-Idade , Placa Aterosclerótica/patologia , Valor Preditivo dos Testes , Estudos Prospectivos , Tomografia de Coerência Óptica/métodos , Resultado do Tratamento
19.
Int J Cardiol ; 351: 25-31, 2022 Mar 15.
Artigo em Inglês | MEDLINE | ID: mdl-34979152

RESUMO

BACKGROUND: Several studies have compared surface electrocardiographic changes following different self-expandable (SE) (Evolut (Medtronic, USA); Acurate (Boston Scientific, USA); Portico (Abbott, USA); and Allegra (NVT, Germany)) and balloon-expandable (BE) Sapien-3 (Edwards Lifesciences, USA) transcatheter heart valves. We aimed to compare these prosthesis with the novel Myval BE prosthesis (Meril Life, India). METHODS: Academic European registry of consecutive patients with severe aortic stenosis who received any of the 6 aforementioned valves. Baseline, post-procedural, and discharge 12­leads electrocardiograms (ECG) were centrally analyzed and compared. RESULTS: A total of 1131 patients were included: 135 Myval (11.9%), 290 Sapien-3 (25.6%), 298 Evolut (26.3%), 180 Acurate (15.9%), 125 Portico (11.1%), and 103 Allegra (9.1%). There were no baseline differences in intraventricular conduction disturbances rate. Compared to the novel BE Myval, there were similar procedural and in-hospital outcomes. Similar rates of early new permanent pacemaker implant (PPI) were observed amongst Myval (7.4%), Sapien-3 (13.4%), and Acurate (9.1%), but Evolut, Portico, and Allegra presented significantly higher rates (18.5%, p = 0.003; 29.5% p < 0.001 and 22%, p = 0.001, respectively). Central analysis of ECGs, unraveled significant prolongation of the PR segment with Evolut, Portico and Allegra whereas Evolut, Acurate, and Portico showed significant QRS widening compared to Myval. However, at discharge no differences in PR segment duration were observed while, Evolut, and Portico- but not Acurate, Allegra or Sapien-3 - still presented significant widening of QRS segment compared to Myval. CONCLUSIONS: After blinded central ECG analysis, the novel Myval balloon-expandable prosthesis was associated with a low rate of early conduction disturbances.


Assuntos
Estenose da Valva Aórtica , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico , Estenose da Valva Aórtica/cirurgia , Humanos , Desenho de Prótese , Resultado do Tratamento
20.
Catheter Cardiovasc Interv ; 78(1): 14-9, 2011 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-21681888

RESUMO

OBJECTIVES: The objective of this study was to compare the efficacy and long-term clinical outcome of manual thrombus aspiration with the Export catheter (Medtronic, Minneapolis, MN) versus mechanical thrombus cutting/aspiration with the X-sizer system (eV3, White Bear Lake, MN) in primary percutaneous coronary intervention (PPCI). BACKGROUND: In PPCI for acute ST-segment elevation myocardial infarction (STEMI), markers of myocardial reperfusion are improved with adjunctive thrombectomy. Previous studies of different devices showed a variability in performance, suitability, and short-term clinical outcome. In current literature, no direct comparison is available. METHODS: We prospectively randomized 201 patients admitted for PPCI for STEMI to either the Export catheter or the X-sizer prior to stent deployment. Technical success in advancing to and across the lesion, improvement of flow, reduction of thrombus, and the effect on ST-segment resolution were examined. The primary endpoint of the follow-up study was the combined endpoint of cardiac death, recurrent myocardial infarction (MI), or target-vessel revascularization (TVR) at 3 years. RESULTS: Although the Export catheter was more successfully deployed, other procedural parameters were similar with a trend toward better ST-segment resolution (56.6% vs. 44%; P = 0.06) as compared to the X-sizer system. The occurrence of the primary clinical endpoint at 3 years was 22.2% and 18.6%, respectively (HR 1.20; 95% CI 0.65-2.22; P = 0.35). CONCLUSION: Despite shorter procedural times, better lesion crossing, and fewer complications, both surrogate endpoints as well as 3-year clinical follow-up were similar with the use of the Export catheter as compared to the X-sizer system.


Assuntos
Angioplastia Coronária com Balão , Trombose Coronária/terapia , Infarto do Miocárdio/terapia , Trombectomia/métodos , Idoso , Angioplastia Coronária com Balão/efeitos adversos , Angioplastia Coronária com Balão/instrumentação , Angioplastia Coronária com Balão/mortalidade , Catéteres , Distribuição de Qui-Quadrado , Trombose Coronária/complicações , Trombose Coronária/mortalidade , Desenho de Equipamento , Feminino , Humanos , Estimativa de Kaplan-Meier , Masculino , Pessoa de Meia-Idade , Infarto do Miocárdio/etiologia , Infarto do Miocárdio/mortalidade , Países Baixos , Estudos Prospectivos , Desenho de Prótese , Recidiva , Medição de Risco , Fatores de Risco , Stents , Sucção , Trombectomia/efeitos adversos , Trombectomia/instrumentação , Trombectomia/mortalidade , Fatores de Tempo , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA