Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 48
Filtrar
Mais filtros

Tipo de documento
Intervalo de ano de publicação
1.
Am Heart J ; 2024 Jun 03.
Artigo em Inglês | MEDLINE | ID: mdl-38838970

RESUMO

BACKGROUND: The impact of prosthesis-patient mismatch (PPM) on major endpoints after transcatheter aortic valve replacement (TAVR) is controversial and the effects on progression of heart damage are poorly investigated. Therefore, our study aims to evaluate the prevalence and predictors of PPM in a "real world" cohort of patients at intermediate and low surgical risk, its impact on mortality and the clinical-echocardiographic progression of heart damage. METHODS: 963 patients who underwent TAVR procedure between 2017 and 2021, from the RECOVERY-TAVR international multicenter observational registry, were included in this analysis. Multiparametric echocardiographic data of these patients were analyzed at 1-year follow-up (FU). Clinical and echocardiographic features were stratified by presence of PPM and PPM severity, as per the most current international recommendations, using VARC-3 criteria. RESULTS: 18% of patients developed post-TAVR. PPM, and 7.7% of the whole cohort had severe PPM. At baseline, 50.3% of patients with PPM were male (vs 46.2% in the cohort without PPM, p=0.33), aged 82 (IQR 79-85y) years vs 82 (IQR 78-86 p=0.46), and 55.6% had Balloon-Expandable valves implanted (vs 46.8% of patients without PPM, p=0.04); they had smaller left ventricular outflow tract (LVOT) diameter (20 mm, IQR 19-21 vs 20 mm, IQR 20-22, p=0.02), reduced SVi (34.2 vs 38 ml/m2, p<0.01) and transaortic flow rate (190.6 vs 211 ml/s, p<0.01). At pre-discharge FU patients with PPM had more paravalvular aortic regurgitation (moderate-severe AR 15.8% vs 9.2%, p<0.01). At 1-year FU, maladaptive alterations of left ventricular parameters were found in patients with PPM, with a significant increase in end-systolic diameter (33 mm vs 28 mm, p=0.03) and a significant increase in left ventricle end systolic indexed volume in those with moderate and severe PPM (52 IQR 42-64 and 52, IQR 41-64 vs.44 IQR 35-59 in those without, p=0.02)). No evidence of a significant impact of PPM on overall (p=0.71) and CV (p=0.70) mortality was observed. Patients with moderate/severe PPM had worse NYHA functional class at 1 year (NYHA III-IV 13% vs 7.8%, p=0.03). Prosthesis size≤23 mm (OR 11.6, 1.68-80.1) was an independent predictor of PPM, while SVi (OR 0.87, 0.83-0.91, p<0.001) and LVOT diameter (OR 0.79, 0.65-0.95, p=0.01) had protective effect. CONCLUSIONS: PPM was observed in 18% of patients undergoing TAVR. Echocardiographic evaluations demonstrated a PPM-related pattern of early ventricular maladaptive alterations, possibly precursor to a reduction in cardiac function, associated with a significant deterioration in NYHA class at 1 year. These findings emphasize the importance of prevention of PPM of any grade in patients undergoing TAVR procedure, especially in populations at risk.

2.
Cardiovasc Diabetol ; 23(1): 35, 2024 01 20.
Artigo em Inglês | MEDLINE | ID: mdl-38245750

RESUMO

BACKGROUND: Diabetes mellitus (DM) is associated with a worse prognosis in patients with heart failure. Our aim was to analyze the clinical and imaging features of patients with DM and their association with outcomes in comparison to nondiabetic patients in a cohort of patients with nonischemic dilated cardiomyopathy (DCM). METHODS: This is a prospective cohort study of patients with DCM evaluated in a tertiary care center from 2018 to 2021. Transthoracic echocardiography and cardiac magnetic resonance findings were assessed. A high-risk late gadolinium enhancement (LGE) pattern was defined as epicardial, transmural, or septal plus free-wall. The primary outcome was a composite of heart failure hospitalizations and all-cause mortality. Multivariable analyses were performed to evaluate the impact of DM on outcomes. RESULTS: We studied 192 patients, of which 51 (26.6%) had DM. The median left ventricular ejection fraction was 30%, and 106 (55.2%) had LGE. No significant differences were found in systolic function parameters between patients with and without DM. E/e values were higher (15 vs. 11.9, p = 0.025), and both LGE (68.6% vs. 50.4%; p = 0.025) and a high-risk LGE pattern (31.4% vs. 18.5%; p = 0.047) were more frequently found in patients with DM. The primary outcome occurred more frequently in diabetic patients (41.2% vs. 23.6%, p = 0.017). DM was an independent predictor of outcomes (OR 2.01; p = 0.049) and of LGE presence (OR 2.15; p = 0.048) in the multivariable analysis. Patients with both DM and LGE had the highest risk of events (HR 3.1; p = 0.003). CONCLUSION: DM is related to a higher presence of LGE in DCM patients and is an independent predictor of outcomes. Patients with DM and LGE had a threefold risk of events. A multimodality imaging approach allows better risk stratification of these patients and may influence therapeutic options.


Assuntos
Cardiomiopatia Dilatada , Diabetes Mellitus , Insuficiência Cardíaca , Humanos , Cardiomiopatia Dilatada/complicações , Cardiomiopatia Dilatada/diagnóstico por imagem , Meios de Contraste , Volume Sistólico , Gadolínio , Função Ventricular Esquerda , Estudos Prospectivos , Diabetes Mellitus/diagnóstico , Diabetes Mellitus/epidemiologia , Prognóstico , Insuficiência Cardíaca/etiologia , Insuficiência Cardíaca/complicações , Valor Preditivo dos Testes , Imagem Cinética por Ressonância Magnética
3.
Clin Sci (Lond) ; 135(1): 143-159, 2021 01 15.
Artigo em Inglês | MEDLINE | ID: mdl-33355632

RESUMO

Myocardial infarction (MI) is associated with renal alterations resulting in poor outcomes in patients with MI. Renal fibrosis is a potent predictor of progression in patients and is often accompanied by inflammation and oxidative stress; however, the mechanisms involved in these alterations are not well established. Endoplasmic reticulum (ER) plays a central role in protein processing and folding. An accumulation of unfolded proteins leads to ER dysfunction, termed ER stress. Since the kidney is the organ with highest protein synthesis fractional rate, we herein investigated the effects of MI on ER stress at renal level, as well as the possible role of ER stress on renal alterations after MI. Patients and MI male Wistar rats showed an increase in the kidney injury marker neutrophil gelatinase-associated lipocalin (NGAL) at circulating level or renal level respectively. Four weeks post-MI rats presented renal fibrosis, oxidative stress and inflammation accompanied by ER stress activation characterized by enhanced immunoglobin binding protein (BiP), protein disulfide-isomerase A6 (PDIA6) and activating transcription factor 6-alpha (ATF6α) protein levels. In renal fibroblasts, palmitic acid (PA; 50-200 µM) and angiotensin II (Ang II; 10-8 to 10-6M) promoted extracellular matrix, superoxide anion production and inflammatory markers up-regulation. The presence of the ER stress inhibitor, 4-phenylbutyric acid (4-PBA; 4 µM), was able to prevent all of these modifications in renal cells. Therefore, the data show that ER stress mediates the deleterious effects of PA and Ang II in renal cells and support the potential role of ER stress on renal alterations associated with MI.


Assuntos
Estresse do Retículo Endoplasmático , Fibroblastos/patologia , Nefropatias/etiologia , Rim/patologia , Infarto do Miocárdio/complicações , Adulto , Animais , Células Cultivadas , Modelos Animais de Doenças , Estresse do Retículo Endoplasmático/efeitos dos fármacos , Feminino , Fibroblastos/efeitos dos fármacos , Fibroblastos/metabolismo , Fibrose , Humanos , Mediadores da Inflamação/metabolismo , Rim/efeitos dos fármacos , Rim/metabolismo , Nefropatias/metabolismo , Nefropatias/patologia , Nefropatias/prevenção & controle , Masculino , Pessoa de Meia-Idade , Estresse Oxidativo , Ácido Palmítico/farmacologia , Fenilbutiratos/farmacologia , Ratos Wistar , Transdução de Sinais
4.
Echocardiography ; 36(6): 1217-1218, 2019 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-31116438

RESUMO

We present the case of a healthy young woman that was evaluated before participation in amateur sports. A systolic and diastolic murmur was heard during the physical examination. Two-dimensional echocardiography was performed, and a direct insertion of the posteromedial papillary muscle into the mitral valve leaflets was found. Mild mitral stenosis and moderate regurgitation were also found. Because she was asymptomatic, a follow-up in 6 months was planned to control the evaluation of her valve disease.


Assuntos
Ecocardiografia/métodos , Sopros Cardíacos/complicações , Insuficiência da Valva Mitral/complicações , Estenose da Valva Mitral/complicações , Valva Mitral/diagnóstico por imagem , Músculos Papilares/anormalidades , Adulto , Cardiomiopatia Hipertrófica , Feminino , Humanos , Insuficiência da Valva Mitral/diagnóstico por imagem , Estenose da Valva Mitral/diagnóstico por imagem , Músculos Papilares/diagnóstico por imagem
5.
Echocardiography ; 36(4): 742-751, 2019 04.
Artigo em Inglês | MEDLINE | ID: mdl-30805998

RESUMO

PURPOSE: Vegetation size is a prognostic predictor in infective endocarditis (IE) and guides surgical management. The aim of this study was to evaluate the accuracy of real-time 3-dimensional transesophageal echocardiography (RT3DTEE) compared to 2DTEE in the diagnosis and characterization of vegetation, as well as its potential clinical impact. METHODS: Two hundred and three consecutive patients with IE were recruited (2009-2016) and retrospectively analyzed. Vegetation diameters and area from 68 patients were measured by 2DTEE and RT3DTEE at admission. The association between size and systemic embolisms was evaluated with logistic regression models. Differences in the discriminative power for the best dimensions' cutoff points were assessed by comparing the area under the ROC curves (AUC). RESULTS: Vegetation size and area were larger by RT3DTEE (P < 0.001) than by 2DTEE, and RT3DTEE was especially relevant in the characterization of nonfiliform vegetation, Morphology was strongly associated with friability, being sessile vegetation less likely to embolize, compared to filiform and raceme-shaped ones (15.4% vs 46% vs 50%). Major diameter by RT3DTEE had better embolic predictive performance than 2DTEE (AUC 0.76 [0.57-0.89] vs 0.71 [0.53-0.86]; P = 0.611). The best cutoff points associated with embolic events during the infection were 17 mm for RT3DTEE and 15 mm for 2DTEE. Based exclusively on vegetation size, the proportion of patients meeting a surgical indication according to current guidelines is higher using RT3DTEE. CONCLUSIONS: RT3DTEE allows a better characterization of IE vegetation than 2DTEE, what may have a clinical impact on surgical management and also prognostic due to a more accurate prediction of embolic risk.


Assuntos
Ecocardiografia Tridimensional/métodos , Ecocardiografia Transesofagiana/métodos , Endocardite/diagnóstico por imagem , Idoso , Endocárdio/diagnóstico por imagem , Endocárdio/microbiologia , Feminino , Humanos , Masculino , Reprodutibilidade dos Testes , Estudos Retrospectivos , Índice de Gravidade de Doença
6.
Circ J ; 82(11): 2880-2886, 2018 10 25.
Artigo em Inglês | MEDLINE | ID: mdl-30135324

RESUMO

BACKGROUND: Prosthesis-patient mismatch (PPM) after transcatheter aortic valve replacement (TAVR) remains an important issue. The aim of this study was to assess the value of a new discongruence index, to predict PPM after TAVR.Methods and Results: A total of 185 patients with severe aortic stenosis who underwent TAVR with the Edwards Sapien prosthesis or CoreValve Revalving system were included (Edwards valve, n=119; Core Valve Revalving system, n=66). Discongruence index was calculated pre-procedurally as the ratio of selected transcatheter valve size (mm) to body surface area (cm2). PPM was defined as effective orifice area (EOA) ≤0.85 cm2/m2 on transthoracic echocardiography before hospital discharge. Mean age was 82±5 years and 72 patients (38.9%) were men. The overall incidence of post-TAVR PPM was 35.1% (n=65). Discongruence index correlated with post-TAVR indexed EOA (y=0.18+0.057x; P<0.001). On multivariate logistic regression analysis, discongruence index was the only independent predictor of post-TAVR PPM (OR, 0.15; 95% CI: 0.03-0.66; P=0.012), and the area under the receiver operating characteristic curve was 0.62 (95% CI: 0.54-0.70, P=0.003), with an optimal cut-off point of 15.02 (sensitivity, 86.2%; specificity, 72.5%; positive predictive value, 74.3%; negative predictive value, 83.4%). CONCLUSIONS: The new discongruence index may be useful tool to predict PPM after TAVR.


Assuntos
Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Ecocardiografia , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino
7.
Catheter Cardiovasc Interv ; 90(5): 809-816, 2017 Nov 01.
Artigo em Inglês | MEDLINE | ID: mdl-27515377

RESUMO

OBJECTIVES: To evaluate the safety and midterm hemodynamic results of direct transcatheter aortic valve replacement (TAVR) without pre-implantation balloon aortic valvuloplasty (BAV). BACKGROUND: BAV was considered a mandatory previous step in TAVR procedures. METHODS: A total of 339 consecutive patients who underwent transfemoral TAVR were prospectively selected. A 1:1 matching was conducted, pairing age, prosthesis type (self-expandable or balloon expandable) and size, and valve calcification grade (48% with moderate to severe valve calcification). Finally, 102 pairs (102 patients with previous BAV and 102 without BAV) were obtained. RESULTS: Direct TAVR was feasible in all patients without any crossover to BAV group. Device success was achieved in 91.2% and 90.2% of cases in direct TAVR and pre-BAV groups (P = 0.810), respectively, without any differences in balloon postdilation rate and residual aortic regurgitation. The amount of contrast agent, acute kidney injury and myocardial injury was significantly lower in the direct implantation group (P < 0.05). No differences were found in 30-day and 1-year mortality between both groups (4.9% vs. 9.8%, P = 0.177 and 14.0% vs. 23.8%, P = 0.771, respectively). Hemodynamic parameters remained stable after 1-year follow-up in both groups. CONCLUSIONS: Direct transfemoral TAVR without prior BAV was safe in patients with calcified severe aortic stenosis. Pre-implantation BAV could be omitted in patients undergoing TAVR, without influence in procedure success rate, and subsequent patients' clinical course and valve hemodynamic performance. © 2016 Wiley Periodicals, Inc.


Assuntos
Estenose da Valva Aórtica/cirurgia , Valva Aórtica/patologia , Valva Aórtica/cirurgia , Valvuloplastia com Balão , Calcinose/cirurgia , Hemodinâmica , Substituição da Valva Aórtica Transcateter , Idoso , Idoso de 80 Anos ou mais , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/fisiopatologia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/mortalidade , Estenose da Valva Aórtica/fisiopatologia , Valvuloplastia com Balão/efeitos adversos , Valvuloplastia com Balão/mortalidade , Calcinose/diagnóstico por imagem , Calcinose/mortalidade , Calcinose/fisiopatologia , Feminino , Próteses Valvulares Cardíacas , Humanos , Estimativa de Kaplan-Meier , Masculino , Estudos Prospectivos , Desenho de Prótese , Recuperação de Função Fisiológica , Fatores de Risco , Índice de Gravidade de Doença , Fatores de Tempo , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/instrumentação , Substituição da Valva Aórtica Transcateter/mortalidade , Resultado do Tratamento , Procedimentos Desnecessários
8.
J Mol Cell Cardiol ; 92: 96-104, 2016 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-26780438

RESUMO

Lysyl oxidase (LOX) is an extracellular matrix (ECM)-modifying enzyme that has been involved in cardiovascular remodeling. We explore the impact of LOX inhibition in ECM alterations induced by obesity in the cardiovascular system. LOX is overexpressed in the heart and aorta from rats fed a high-fat diet (HFD). ß-Aminopropionitrile (BAPN), an inhibitor of LOX activity, significantly attenuated the increase in body weight and cardiac hypertrophy observed in HFD rats. No significant differences were found in cardiac function or blood pressure among any group. However, HFD rats showed cardiac and vascular fibrosis and enhanced levels of superoxide anion (O2(-)), collagen I and transforming growth factor ß (TGF-ß) in heart and aorta and connective tissue growth factor (CTGF) in aorta, effects that were attenuated by LOX inhibition. Interestingly, BAPN also prevented the increase in circulating leptin levels detected in HFD fed animals. Leptin increased protein levels of collagen I, TGF-ß and CTGF, Akt phosphorylation and O2(-) production in both cardiac myofibroblasts and vascular smooth muscle cells in culture, while LOX inhibition ameliorated these alterations. LOX knockdown also attenuated leptin-induced collagen I production in cardiovascular cells. Our findings indicate that LOX inhibition attenuates the fibrosis and the oxidative stress induced by a HFD on the cardiovascular system. The reduction of leptin levels by BAPN in vivo and the ability of this compound to inhibit leptin-induced profibrotic mediators and ROS production in cardiac and vascular cells suggest that interactions between leptin and LOX regulate downstream events responsible for myocardial and vascular fibrosis in obesity.


Assuntos
Fibrose/tratamento farmacológico , Leptina/metabolismo , Miocárdio/metabolismo , Obesidade/tratamento farmacológico , Proteína-Lisina 6-Oxidase/biossíntese , Aminopropionitrilo/administração & dosagem , Animais , Aorta/metabolismo , Aorta/patologia , Pressão Sanguínea/efeitos dos fármacos , Peso Corporal , Dieta Hiperlipídica , Matriz Extracelular/efeitos dos fármacos , Matriz Extracelular/genética , Fibrose/genética , Fibrose/patologia , Regulação da Expressão Gênica/efeitos dos fármacos , Humanos , Miocárdio/patologia , Obesidade/genética , Obesidade/patologia , Proteína-Lisina 6-Oxidase/antagonistas & inibidores , Proteína-Lisina 6-Oxidase/genética , Ratos , Espécies Reativas de Oxigênio/metabolismo
9.
Echocardiography ; 32(4): 644-53, 2015 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-25091933

RESUMO

BACKGROUND/OBJECTIVES: Atrial fibrillation (AF) is the most common cardiac arrhythmia and is associated with a significantly high risk of stroke and systemic embolism. The aim of our study was to assess the association between left atrium (LA) mechanics measured by 3D wall-motion tracking (3DWMT) technology and the most common thromboembolic risk scores (CHADS2, CHA2DS2-VASc). METHODS: A total of 101 consecutive patients with permanent AF referred were included. Conventional bidimensional (2D) LA parameters, and LA mechanics by means of 3DWMT were studied. Association between LA 2D and 3DWMT parameters and both risk scores was evaluated as well as its correlation with every component of the score individually. RESULTS: Mean age was 78 ± 10 years. Mean CHADS2 was 2.7 ± 1.3 and mean CHA2DS2-VASc was 4.4 ± 1.7. Values of 2D and 3DWTM LA parameters were: 2D area 26.4 ± 9.7 cm(2) , 2D volume index 49.4 ± 10.1 mL/m(2) , 3DWMT left atrial emptying fraction (LAEF) 15.9 ± 8.4%, longitudinal strain 9.1 ± 4.5% and area strain 14.9 ± 8.8%. Linear regression analysis showed statistically significant correlation between LA longitudinal strain and LAEF with CHADS2 and CHA2DS2-VASc scores. For each 10% variation in longitudinal strain, CHADS2 and CHA2DS2-VASc scores change in 0.7 and 0.8 points, respectively. CONCLUSIONS: Left atrial longitudinal strain and emptying fraction assessed by 3D WMT technology have correlation with both CHADS2 and CHA2DS2-VASc scores. Each 10% of variation in longitudinal strain represents a 0.7 and 0.8 points change in those risk scores. LA mechanics evaluation might provide additional value to risk scores and could be considered to be a predictor of stroke in patients with AF.


Assuntos
Fibrilação Atrial/epidemiologia , Ecocardiografia Tridimensional/estatística & dados numéricos , Átrios do Coração/diagnóstico por imagem , Átrios do Coração/fisiopatologia , Tromboembolia/diagnóstico por imagem , Tromboembolia/epidemiologia , Idoso , Fibrilação Atrial/diagnóstico por imagem , Causalidade , Comorbidade , Ecocardiografia Tridimensional/métodos , Feminino , Humanos , Aumento da Imagem/métodos , Interpretação de Imagem Assistida por Computador/métodos , Incidência , Masculino , Reprodutibilidade dos Testes , Medição de Risco , Sensibilidade e Especificidade , Espanha/epidemiologia
11.
Methods Cell Biol ; 185: 151-164, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38556446

RESUMO

Cardiovascular disease (CVD) is the main cause of death worldwide, with myocardial infarction (MI) being the most prevalent pathology involved in CVD. MI is characterized by a deficiency in oxygen supply to the myocardium, thereby promoting ventricular remodeling of the ischemic and remote zone of the heart. Cardiac remodeling associated with MI could promote the development of heart failure and finally death. For these reasons, it is important to develop animal models that mimic human cardiac disease which could help to identify new mechanisms involved in the pathology and, consequently, develop new therapeutic strategies. We herein describe in detail a protocol for MI induction with low mortality rate (<15%) in rats by ligation of the left anterior descending artery. In addition, we also describe two imaging techniques which allow to evaluate cardiac structure and function-including deformation parameters in rats such as transthoracic echocardiography and cardiac magnetic resonance. This animal model could be useful for acute and chronic studies and for evaluating the potential usefulness of different treatments.


Assuntos
Infarto do Miocárdio , Função Ventricular Esquerda , Ratos , Humanos , Animais , Modelos Animais de Doenças , Infarto do Miocárdio/diagnóstico por imagem , Miocárdio , Coração
12.
J Clin Med ; 13(12)2024 Jun 17.
Artigo em Inglês | MEDLINE | ID: mdl-38930068

RESUMO

Background/Objectives: Severe aortic stenosis (AS) is the most frequent valvular heart disease. Models for stratifying cardiac damage associated with aortic stenosis have been developed to predict outcomes following valve replacement. However, evidence regarding morphological and functional evolution, as well as potential changes in the degree of cardiac damage, is limited. We aim to provide information on the evolution of cardiac morphology and the function of patients undergoing transcatheter aortic valve replacement (TAVR) who have been classified using a cardiac damage staging system. Methods: In total, 496 patients were included in the analysis, and were classified into four stages based on the extent of cardiac damage as follows: Stage 0, no cardiac damage: left ventricle global longitudinal strain (LV-GLS) < -17%; right ventricular-arterial coupling (RVAc) ≥ 0.35), and absence of significant mitral regurgitation (MR). Stage 1, left-sided subclinical damage: LV-GLS ≥ -17%. Stage 2, left-sided damage: significant MR. Stage 3, right-sided damage: RVAc < 0.35. Results: The mean age was 82.1 ± 5.9 years, and 53.0% were female. In total, 24.5% of patients met the criteria for Stage 0, and Stage 1 included 42.8% of patients, Stage 2 included 16.5%, and Stage 3 comprised 16.2% of patients. Mortality was 8.4% for stage 0, 17.4% for stage 1, 25.6% for stage 2, and 28.6% for stage 3 patients (p = 0.004). Diabetes mellitus (DM) (p = 0.047) and chronic kidney disease (CKD) (p = 0.024) were the only clinical predictors of no change or worsening in the stage of cardiac damage. Regarding echocardiographic variables, concomitant tricuspid, and mitral regurgitation, ≥ 2 were both significantly associated with no change or worsening, also (p < 0.001). Conclusions: Cardiac damage that is secondary to severe aortic stenosis has morphological and functional repercussions that, even after valve replacement, persist and might worsen the prognosis.

13.
Artigo em Inglês, Espanhol | MEDLINE | ID: mdl-38521440

RESUMO

INTRODUCTION AND OBJECTIVES: Diffuse homogeneous hypoechoic leaflet thickening, with a wavy leaflet motion documented by transesophageal echocardiography (TEE), has been described in some cases of prosthetic valve endocarditis (PVE) involving aortic bioprosthesis (AoBio-PVE). This echocardiographic finding has been termed valvulitis. We aimed to estimate the prevalence of valvulitis, precisely describe its echocardiographic characteristics, and determine their clinical significance in patients with AoBio-PVE. METHODS: From 2011 to 2022, 388 consecutive patients with infective endocarditis (IE) admitted to a tertiary care hospital were prospectively included in a multipurpose database. For this study, all patients with AoBio-PVE (n=86) were selected, and their TEE images were thoroughly evaluated by 3 independent cardiologists to identify all cases of valvulitis. RESULTS: The prevalence of isolated valvulitis was 12.8%, and 20.9% of patients had valvulitis accompanied by other classic echocardiographic findings of IE. A total of 9 out of 11 patients with isolated valvulitis had significant valve stenosis, whereas significant aortic valve regurgitation was documented in only 1 patient. Compared with the other patients with AoBio-PVE, cardiac surgery was less frequently performed in patients with isolated valvulitis (27.3% vs 62.7%, P=.017). In 4 out of 5 patients with valve stenosis who did not undergo surgery but underwent follow-up TEE, valve gradients significantly improved with appropriate antibiotic therapy. CONCLUSIONS: Valvulitis can be the only echocardiographic finding in infected AoBio and needs to be identified by imaging specialists for early diagnosis. However, this entity is a diagnostic challenge and additional imaging techniques might be required to confirm the diagnosis. Larger series are needed.

14.
Eur Heart J Cardiovasc Imaging ; 24(12): 1608-1617, 2023 11 23.
Artigo em Inglês | MEDLINE | ID: mdl-37315235

RESUMO

AIMS: Cardiac damage staging has been postulated as a prognostic tool in patients undergoing transcatheter aortic valve replacement (TAVR). The aims of our study are (i) to validate cardiac damage staging systems previously described to stratify patients with aortic stenosis (AS), (ii) to identify independent risk factors for 1-year mortality in patients with severe AS undergoing TAVR, and (iii) to develop a novel staging model and compare its predictive performance to that of the above mentioned. METHODS AND RESULTS: Patients undergoing TAVR from 2017 to 2021 were included in a single-centre prospective registry. Transthoracic echocardiography was performed in all patients before TAVR. Logistic and Cox's regression analysis were used to identify predictors of 1-year all-cause mortality. In addition, patients were classified based on previously published cardiac damage staging systems, and the predictive performance of the different scores was measured.Four hundred and ninety-six patients (mean age 82.1 ± 5.9 years, 53% female) were included. Mitral regurgitation (MR), left ventricle global longitudinal strain (LV-GLS) and right ventricular-arterial coupling (RVAc) were independent predictors of all-cause 1-year mortality. A new classification system with four different stages was developed using LV-GLS, MR, and RVAc. The area under the receiver operating characteristic curve was 0.66 (95% confidence interval 0.63-0.76), and its predictive performance was superior compared with the previously published systems (P < 0.001). CONCLUSION: Cardiac damage staging might have an important role in patients' selection and better timing for TAVR. A model that includes LV-GLS, MR, and RVAc may help to improve prognostic stratification and contribute to better selection of patients undergoing TAVR.


Assuntos
Estenose da Valva Aórtica , Insuficiência da Valva Mitral , Substituição da Valva Aórtica Transcateter , Humanos , Feminino , Idoso , Idoso de 80 Anos ou mais , Masculino , Valva Aórtica/cirurgia , Ventrículos do Coração/cirurgia , Função Ventricular Esquerda , Resultado do Tratamento , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/etiologia , Substituição da Valva Aórtica Transcateter/métodos , Insuficiência da Valva Mitral/cirurgia , Fatores de Risco , Estudos Retrospectivos , Índice de Gravidade de Doença
15.
Eur Heart J Cardiovasc Imaging ; 24(8): 1052-1061, 2023 07 24.
Artigo em Inglês | MEDLINE | ID: mdl-36752044

RESUMO

AIMS: The prognostic impact of flow trajectories according to stroke volume index (SVi) and transvalvular flow rate (FR) in patients with severe aortic stenosis (AS) undergoing transcatheter aortic valve replacement (TAVR) remains poorly assessed. We evaluated and compared SVi and FR prior and after TAVR for severe AS. METHODS AND RESULTS: Patients were categorized according to SVi (<35 mL/m2) and FR (<200 mL/s). The association of pre- and post-TAVR SVi and FR with all-cause mortality up to 3 years was assessed with multivariable Cox regression models. Among 980 patients with pre-TAVR flow assessment, SVi was reduced in 41.3% and FR in 48.1%. Baseline flow status was not an independent mortality predictor [SVi: hazard ratio (HR) 1.22, 95% confidence interval (CI) 0.85-1.82, FR: HR 0.78, 95% CI 0.48-1.27]. Among 731 patients undergoing early (5 days, interquartile range 2-29) post-TAVR flow assessment, SVi recovered in 40.1% and FR in 49.0% patients with baseline low flow. Reduced FR following TAVR was an independent predictor of mortality (HR 1.67, 95% CI 1.02-2.74), whereas SVi was not (HR 0.97, 95% CI 0.53-1.78). Three-year estimated mortality in patients with recovered FR was lower than that in patients with reduced FR (13.3 vs. 37.7% vs, P = 0.003) and similar to that in patients with normal baseline FR (P = 0.317). CONCLUSION: Baseline flow status was not an independent predictor of mid-term mortality among all-comers with severe AS undergoing TAVR. Flow recovery early after TAVR was frequent. Post-TAVR FR, but not SVi, was independently associated with mid-term all-cause mortality. By impacting flow status, AV replacement modifies the association of flow status with outcomes.


Assuntos
Estenose da Valva Aórtica , Substituição da Valva Aórtica Transcateter , Humanos , Substituição da Valva Aórtica Transcateter/métodos , Volume Sistólico , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Resultado do Tratamento , Fatores de Risco , Estudos Retrospectivos , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Índice de Gravidade de Doença
16.
Sci Rep ; 12(1): 10713, 2022 06 23.
Artigo em Inglês | MEDLINE | ID: mdl-35739236

RESUMO

More than 91,000 fatalities due to Coronavirus Disease 2019 (COVID-19) have occurred in Spain. Several factors are associated with increased mortality in this disease, including cardiovascular risk factors (CVRF). However, information on the cardiac function of patients prior to the onset of COVID-19 is scarce and the potential impact it may have is uncertain. The aim of the EchoVID study was to describe the potential association between CVRF and cardiac function status prior to SARS-CoV-2 infection and in-hospital mortality. We studied clinical characteristics and cardiac function of patients admitted during the first wave of COVID-19. All patients had a transthoracic echocardiogram performed in the previous 12 months prior to diagnosis; conventional systolic and diastolic function parameters were analyzed. Logistic regression analysis was performed to identify predictors of in-hospital mortality. We included 296 individuals. Median age was higher in the group of patients who died (81.0 vs 76.1 years; p = 0.007). No significant differences were found in CVRF. Survivors were more frequently receiving anticoagulation therapy (52.9% vs 70.8%; p = 0.003). LVEF, although preserved on average in both groups, was significantly lower in the group of deceased patients (56.9% vs 61.1%; p = 0.017). Average E/e' ratio was higher in the deceased group (11.1 vs 10.1; p = 0.049). Five variables were found to be independently associated with in-hospital mortality due to COVID-19: Age, male gender, LVEF, E/e' ratio and anticoagulation therapy. A model including these variables had an area under the ROC curve of 0.756 (CI 0.669-0.843). The echocardiographic variables included in the model significantly improved the discriminative power, compared to a model including only demographic data. Left ventricular ejection fraction and E/e' ratio prior to SARS-CoV-2 infection are two easily-obtained echocardiographic parameters that provide additional prognostic information over clinical factors when assessing patients admitted for SARS-CoV-2 infection.


Assuntos
COVID-19 , Idoso , Anticoagulantes , Ecocardiografia , Humanos , Masculino , SARS-CoV-2 , Volume Sistólico , Função Ventricular Esquerda
17.
Front Cardiovasc Med ; 9: 995367, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36451918

RESUMO

Background: Over the past years, information about the crosstalk between the epicardial adipose tissue (EAT) and the cardiovascular system has emerged. Notably, in the context of acute myocardial infarction (AMI), EAT might have a potential role in the pathophysiology of ventricular structural changes and function, and the clinical evolution of patients. This study aims to assess the impact of EAT on morpho-functional changes in the left ventricle (LV) and the outcome of patients after an AMI. Methods: We studied prospectively admitted patients to our hospital with a first episode of AMI. All patients underwent percutaneous coronary intervention (PCI) during admission. Transthoracic echocardiography (TTE) was performed within 24-48 h after PCI, as well as blood samples to assess levels of galectin-3 (Gal-3). Cardiac magnetic resonance (CMR) was performed 5-7 days after PCI. Clinical follow-up was performed at 1 and 5 years after MI. Results: Mean age of our cohort (n = 41) was 57.5 ± 10 years, and 38 (93%) were male. Nine patients had normal BMI, 15 had overweight (BMI 25-30), and 17 were obese (BMI > 30). Twenty three patients (56%) had ≥ 4 mm thickness of EAT measured with echo. In these patients, baseline left ventricular ejection fraction (LVEF) after AMI was significantly lower, as well as global longitudinal strain. EAT thickness ≥ 4 m patients presented larger infarct size, higher extracellular volume, and higher T1 times than patients with EAT < 4 mm. As for Gal-3, the median was 16.5 ng/mL [12.7-25.2]. At five-year follow-up 5 patients had major cardiac events, and all of them had EAT ≥ 4 mm. Conclusions: Patients with EAT >4 mm have worse LVEF and GLS, larger infarct size and longer T1 values after a MI, and higher levels of Gal-3. EAT >4 mm was an independent predictor of MACE at 5-year follow-up. EAT thickness is a feasible, noninvasive, low-cost parameter that might provide important information regarding the chronic inflammatory process in the myocardium after an infarction.

18.
Antioxidants (Basel) ; 11(7)2022 Jun 23.
Artigo em Inglês | MEDLINE | ID: mdl-35883722

RESUMO

We have evaluated cardiac function and fibrosis in infarcted male Wistar rats treated with MitoQ (50 mg/kg/day) or vehicle for 4 weeks. A cohort of patients admitted with a first episode of acute MI were also analyzed with cardiac magnetic resonance and T1 mapping during admission and at a 12-month follow-up. Infarcted animals presented cardiac hypertrophy and a reduction in the left ventricular ejection fraction (LVEF) and E- and A-waves (E/A) ratio when compared to controls. Myocardial infarction (MI) rats also showed cardiac fibrosis and endoplasmic reticulum (ER) stress activation. Binding immunoglobulin protein (BiP) levels, a marker of ER stress, were correlated with collagen I levels. MitoQ reduced oxidative stress and prevented all these changes without affecting the infarct size. The LVEF and E/A ratio in patients with MI were 57.6 ± 7.9% and 0.96 ± 0.34, respectively. No major changes in cardiac function, extracellular volume fraction (ECV), or LV mass were observed at follow-up. Interestingly, the myeloperoxidase (MPO) levels were associated with the ECV in basal conditions. BiP staining and collagen content were also higher in cardiac samples from autopsies of patients who had suffered an MI than in those who had died from other causes. These results show the interactions between mitochondrial oxidative stress and ER stress, which can result in the development of diffuse fibrosis in the context of MI.

19.
Artigo em Inglês | MEDLINE | ID: mdl-35006473

RESUMO

Change in longitudinal left ventricular (LV) systolic function serves as an early marker of the deleterious effect of aortic stenosis (AS) and other cardiac comorbidities on cardiac function. We explored the prognostic value of tissue Doppler imaging (TDI)-derived longitudinal LV systolic function, defined by the peak systolic average of lateral and septal mitral annular velocities (average S') among symptomatic patients with severe AS undergoing transcatheter aortic valve implantation (TAVI). 297 consecutive patients with severe AS undergoing TAVI at three european centers with available average S' at preprocedural echocardiography were retrospectively included. The primary endpoint was the Kaplan Meier estimate of all-cause mortality. After a median 18 months (IQR 12-18) follow-up, 36 (12.1%) patients had died. Average S' was associated with all-cause mortality (per 1 cm/sec decrease: HR 1.29, 95%CI 1.03-1.60, p = 0.025), the cut-off of 6.5 cm/sec being the most accurate. Patients with average S' < 6.5 cm/sec (55.2%) presented characteristics of more advanced LV remodeling and functional impairment along with higher burden of cardiac comorbidities, and experienced higher all-cause mortality (17.6% vs. 7.5%, p = 0.007), also when adjusted for in-study outcome predictors (adj-HR: 2.69, 95%CI 1.22-5.93, p = 0.014). Results were consistent among patients with preserved ejection fraction, normal-flow AS, high-gradient AS and in those without LV hypertrophy. Longitudinal LV systolic function assessed by average S' is independently associated with long-term all-cause mortality among TAVI patients. An average S' below 6.5 cm/sec best defines clinically meaningful reduced longitudinal systolic function and may aid clinical risk stratification in these patients.

20.
JACC Cardiovasc Interv ; 15(12): 1266-1274, 2022 06 27.
Artigo em Inglês | MEDLINE | ID: mdl-35738747

RESUMO

BACKGROUND: Data on outcomes of transcatheter aortic valve replacement (TAVR) using balloon-expandable valves (BEVs) or self-expandable valves (SEVs) as well as the impact of center valve preference on these outcomes are limited. OBJECTIVES: The aim of this study was to compare outcomes of TAVR procedures using third-generation BEVs and SEVs stratified by center valve preference. METHODS: In a multicenter registry (n = 17), 13 centers exhibited valve preference (66.6%-90% of volume) and were included. Outcomes were compared between BEVs and SEVs stratified by center valve preference. RESULTS: In total, 7,528 TAVR procedures (3,854 with SEVs and 3,674 with BEVs) were included. The mean age was 81 years, and the mean Society of Thoracic Surgeons score was 5.2. Baseline characteristics were similar between BEVs and SEVs. Need for pacemaker implantation was higher with SEVs at BEV- and SEV-dominant centers (17.8% vs 9.3% [P < 0.001] and 12.7% vs 10.0% [P = 0.036], respectively; HR: 1.51; P for interaction = 0.021), risk for cerebrovascular accident was higher with SEVs at BEV-dominant but not SEV-dominant centers (3.6% vs 1.1% [P < 0.001] and 2.2% vs 1.4% [P = 0.162]; HR: 2.08; P for interaction < 0.01). Aortic regurgitation greater than mild was more frequent with SEVs at BEV-dominant centers and similar with BEVs regardless of center dominance (5.2% vs 2.8% [P < 0.001] and 3.4% vs 3.7% [P = 0.504], respectively). Two-year mortality was higher with SEVs at BEV-dominant centers but not at SEV-dominant centers (21.9% vs 16.9% [P = 0.021] and 16.8% vs 16.5% [P = 0.642], respectively; HR: 1.20; P for interaction = 0.032). CONCLUSIONS: Periprocedural outcomes, aortic regurgitation greater than mild, and 2-year mortality are worse when TAVR is performed using SEVs at BEV-dominant centers. Outcomes are similar regardless of valve type at SEV-dominant centers. The present results stress the need to account for this factor when comparing BEV and SEV outcomes. (The Aortic+Mitral Transcatheter [AMTRAC] Valve Registry; NCT04031274).


Assuntos
Insuficiência da Valva Aórtica , Estenose da Valva Aórtica , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Idoso de 80 Anos ou mais , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Insuficiência da Valva Aórtica/diagnóstico por imagem , Insuficiência da Valva Aórtica/etiologia , Insuficiência da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Humanos , Desenho de Prótese , Sistema de Registros , Fatores de Risco , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/métodos , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA