Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
Mais filtros

Base de dados
Tipo de documento
Assunto da revista
Intervalo de ano de publicação
1.
Dis Colon Rectum ; 2024 Jun 11.
Artigo em Inglês | MEDLINE | ID: mdl-38871678

RESUMO

BACKGROUND: Although accurate preoperative diagnosis of lymph node metastasis is essential for optimizing treatment strategies for low rectal cancer, the accuracy of present diagnostic modalities has room for improvement. OBJECTIVE: To establish a high-precision diagnostic method for lymph node metastasis of low rectal cancer using artificial intelligence. DESIGN: A retrospective observational study. SETTINGS: A single cancer center and a college of engineering in Japan. PATIENTS: Patients with low rectal adenocarcinoma who underwent proctectomy, bilateral lateral pelvic lymph node dissection, and contrast-enhanced multi-detector row computed tomography (slice ≤1 mm) between July 2015 and August 2021 were included in the present study. All pelvic lymph nodes from the aortic bifurcation to the upper edge of the anal canal were extracted, regardless of whether within or beyond the total mesenteric excision area, and pathological diagnoses were annotated for training and validation. MAIN OUTCOME MEASURES: Sensitivity, specificity, positive predictive value, negative predictive value, and accuracy. RESULTS: A total of 596 pathologically negative and 43 positive nodes from 52 patients were extracted and annotated. Four diagnostic methods, with and without using super-resolution images and without using 3D shape data, were performed and compared. The super-resolution + 3D shape data method had the best diagnostic ability for the combination of sensitivity, negative predictive value, and accuracy (0.964, 0.966, and 0.968, respectively), while the super-resolution only method had the best diagnostic ability for the combination of specificity and positive predictive value (0.994 and 0.993, respectively). LIMITATIONS: Small number of patients at a single center and the lack of external validation. CONCLUSIONS: Our results enlightened the potential of artificial intelligence for the method to become another game changer in the diagnosis and treatment of low rectal cancer. See Video Abstract.

2.
Sensors (Basel) ; 24(6)2024 Mar 15.
Artigo em Inglês | MEDLINE | ID: mdl-38544143

RESUMO

How to obtain internal cavity features and perform image matching is a great challenge for laparoscopic 3D reconstruction. This paper proposes a method for detecting and associating vascular features based on dual-branch weighted fusion vascular structure enhancement. Our proposed method is divided into three stages, including analyzing various types of minimally invasive surgery (MIS) images and designing a universal preprocessing framework to make our method generalized. We propose a Gaussian weighted fusion vascular structure enhancement algorithm using the dual-branch Frangi measure and MFAT (multiscale fractional anisotropic tensor) to address the structural measurement differences and uneven responses between venous vessels and microvessels, providing effective structural information for vascular feature extraction. We extract vascular features through dual-circle detection based on branch point characteristics, and introduce NMS (non-maximum suppression) to reduce feature point redundancy. We also calculate the ZSSD (zero sum of squared differences) and perform feature matching on the neighboring blocks of feature points extracted from the front and back frames. The experimental results show that the proposed method has an average accuracy and repeatability score of 0.7149 and 0.5612 in the Vivo data set, respectively. By evaluating the quantity, repeatability, and accuracy of feature detection, our method has more advantages and robustness than the existing methods.


Assuntos
Algoritmos , Laparoscopia , Procedimentos Cirúrgicos Minimamente Invasivos , Veias , Microvasos
3.
Sensors (Basel) ; 20(4)2020 Feb 19.
Artigo em Inglês | MEDLINE | ID: mdl-32093132

RESUMO

LiDAR data contain feature information such as the height and shape of the ground target and play an important role for land classification. The effect of convolutional neural network (CNN) for feature extraction on LiDAR data is very significant, however CNN cannot resolve the spatial relationship of features adequately. The capsule network (CapsNet) can identify the spatial variations of features and is widely used in supervised learning. In this article, the CapsNet is combined with the residual network (ResNet) to design a deep network-ResCapNet for improving the accuracy of LiDAR classification. The capsule network represents the features by vectors, which can account for the direction of the features and the relative position between the features. Therefore, more detailed feature information can be extracted. ResNet protects the integrity of information by passing input information to the output directly, which can solve the problem of network degradation caused by information loss in the traditional CNN propagation process to a certain extent. Two different LiDAR data sets and several classic machine learning algorithms are used for comparative experiments. The experimental results show that ResCapNet proposed in this article `improve the performance of LiDAR classification.

4.
Sensors (Basel) ; 19(22)2019 Nov 12.
Artigo em Inglês | MEDLINE | ID: mdl-31726726

RESUMO

Light detection and ranging (LiDAR) is a frequently used technique of data acquisition and it is widely used in diverse practical applications. In recent years, deep convolutional neural networks (CNNs) have shown their effectiveness for LiDAR-derived rasterized digital surface models (LiDAR-DSM) data classification. However, many excellent CNNs have too many parameters due to depth and complexity. Meanwhile, traditional CNNs have spatial redundancy because different convolution kernels scan and store information independently. SqueezeNet replaces a part of 3 × 3 convolution kernels in CNNs with 1 × 1 convolution kernels, decomposes the original one convolution layer into two layers, and encapsulates them into a Fire module. This structure can reduce the parameters of network. Octave Convolution (OctConv) pools some feature maps firstly and stores them separately from the feature maps with the original size. It can reduce spatial redundancy by sharing information between the two groups. In this article, in order to improve the accuracy and efficiency of the network simultaneously, Fire modules of SqueezeNet are used to replace the traditional convolution layers in OctConv to form a new dual neural architecture: OctSqueezeNet. Our experiments, conducted using two well-known LiDAR datasets and several classical state-of-the-art classification methods, revealed that our proposed classification approach based on OctSqueezeNet is able to provide competitive advantages in terms of both classification accuracy and computational amount.

5.
Int J Comput Assist Radiol Surg ; 18(4): 723-732, 2023 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-36630071

RESUMO

PURPOSE: Lymph node (LN) detection is a crucial step that complements the diagnosis and treatments involved during cancer investigations. However, the low-contrast structures in the CT scan images and the nodes' varied shapes, sizes, and poses, along with their sparsely distributed locations, make the detection step challenging and lead to many false positives. The manual examination of the CT scan slices could be time-consuming, and false positives could divert the clinician's focus. To overcome these issues, our work aims at providing an automated framework for LNs detection in order to obtain more accurate detection results with low false positives. METHODS: The proposed work consists of two stages: candidate generation and false positive reduction. The first stage generates volumes of interest (VOI) of probable LN candidates using a modified U-Net with ResNet architecture to obtain high sensitivity but with the cost of increased false positives. The second-stage processes the obtained candidate LNs for false positive reduction using 3D convolutional neural network (CNN) classifier. We further present an analysis of various deep learning models while decomposing 3D VOI into different representations. RESULTS: The method is evaluated on two publicly available datasets containing CT scans of mediastinal and abdominal LNs. Our proposed approach yields sensitivities of 87% at 2.75 false positives per volume (FP/vol.) and 79% at 1.74 FP/vol. with the mediastinal and abdominal datasets, respectively. Our method presented a competitive performance in terms of sensitivity compared to the state-of-the-art methods and encountered very few false positives. CONCLUSION: We developed an automated framework for LNs detection using a modified U-Net with residual learning and 3D CNNs. The results indicate that our method could achieve high sensitivity with relatively low false positives, which helps avoid ineffective treatments.


Assuntos
Neoplasias , Tomografia Computadorizada por Raios X , Humanos , Tomografia Computadorizada por Raios X/métodos , Redes Neurais de Computação , Linfonodos/diagnóstico por imagem , Mediastino
6.
J Imaging ; 8(5)2022 Apr 25.
Artigo em Inglês | MEDLINE | ID: mdl-35621888

RESUMO

Roadway area calculation is a novel problem in remote sensing and urban planning. This paper models this problem as a two-step problem, roadway extraction, and area calculation. Roadway extraction from satellite images is a problem that has been tackled many times before. This paper proposes a method using pixel resolution to calculate the area of the roads covered in satellite images. The proposed approach uses novel U-net and Resnet architectures called U-net++ and ResNeXt. The state-of-the-art model is combined with the proposed efficient post-processing approach to improve the overlap with ground truth labels. The performance of the proposed road extraction algorithm is evaluated on the Massachusetts dataset and it is shown that the proposed approach outperforms the existing solutions which use models from the U-net family.

7.
Int J Biomed Imaging ; 2015: 109804, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-25949235

RESUMO

Medical diagnosis judges the status of polyp from the size and the 3D shape of the polyp from its medical endoscope image. However the medical doctor judges the status empirically from the endoscope image and more accurate 3D shape recovery from its 2D image has been demanded to support this judgment. As a method to recover 3D shape with high speed, VBW (Vogel-Breuß-Weickert) model is proposed to recover 3D shape under the condition of point light source illumination and perspective projection. However, VBW model recovers the relative shape but there is a problem that the shape cannot be recovered with the exact size. Here, shape modification is introduced to recover the exact shape with modification from that with VBW model. RBF-NN is introduced for the mapping between input and output. Input is given as the output of gradient parameters of VBW model for the generated sphere. Output is given as the true gradient parameters of true values of the generated sphere. Learning mapping with NN can modify the gradient and the depth can be recovered according to the modified gradient parameters. Performance of the proposed approach is confirmed via computer simulation and real experiment.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA