Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Ano de publicação
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
J Hosp Infect ; 148: 77-86, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38554807

RESUMO

BACKGROUND: Pseudomonas aeruginosa (PA) is a common cause of healthcare-associated infection (PA-HAI) in the intensive care unit (ICU). AIM: To describe the epidemiology of PA-HAI in ICUs in Ontario, Canada, and to identify episodes of sink-to-patient PA transmission. METHODS: This was a prospective cohort study of patients in six ICUs from 2018 to 2019, with retrieval of PA clinical isolates, and PA-screening of antimicrobial-resistant organism surveillance rectal swabs, and of sink drain, air, and faucet samples. All PA isolates underwent whole-genome sequencing. PA-HAI was defined using US National Healthcare Safety Network criteria. ICU-acquired PA was defined as PA isolated from specimens obtained ≥48 h after ICU admission in those with prior negative rectal swabs. Sink-to-patient PA transmission was defined as ICU-acquired PA with close genomic relationship to isolate(s) previously recovered from sinks in a room/bedspace occupied 3-14 days prior to collection date of the relevant patient specimen. FINDINGS: Over ten months, 72 PA-HAIs occurred among 60/4263 admissions. The rate of PA-HAI was 2.40 per 1000 patient-ICU-days; higher in patients who were PA-colonized on admission. PA-HAI was associated with longer stay (median: 26 vs 3 days uninfected; P < 0.001) and contributed to death in 22/60 cases (36.7%). Fifty-eight admissions with ICU-acquired PA were identified, contributing 35/72 (48.6%) PA-HAIs. Four patients with five PA-HAIs (6.9%) had closely related isolates previously recovered from their room/bedspace sinks. CONCLUSION: Nearly half of PA causing HAI appeared to be acquired in ICUs, and 7% of PA-HAIs were associated with sink-to-patient transmission. Sinks may be an under-recognized reservoir for HAIs.


Assuntos
Infecção Hospitalar , Unidades de Terapia Intensiva , Infecções por Pseudomonas , Pseudomonas aeruginosa , Humanos , Unidades de Terapia Intensiva/estatística & dados numéricos , Pseudomonas aeruginosa/genética , Pseudomonas aeruginosa/isolamento & purificação , Pseudomonas aeruginosa/classificação , Infecção Hospitalar/epidemiologia , Infecção Hospitalar/microbiologia , Infecção Hospitalar/transmissão , Infecções por Pseudomonas/epidemiologia , Infecções por Pseudomonas/transmissão , Infecções por Pseudomonas/microbiologia , Estudos Prospectivos , Ontário/epidemiologia , Masculino , Pessoa de Meia-Idade , Feminino , Idoso , Adulto , Idoso de 80 Anos ou mais , Sequenciamento Completo do Genoma
2.
J Hosp Infect ; 106(4): 820-827, 2020 12.
Artigo em Inglês | MEDLINE | ID: mdl-32916210

RESUMO

BACKGROUND: Hospital drains may be an important reservoir for carbapenemase-producing Enterobacterales (CPE). AIM: To determine prevalence of CPE in hospital drains exposed to inpatients with CPE, relatedness of drain and patient CPE, and risk factors for drain contamination. METHODS: Sink and shower drains in patient rooms and communal shower rooms exposed to 310 inpatients with CPE colonization/infection were cultured at 10 hospitals. Using short- and long-read whole-genome sequencing, inpatient and corresponding drain CPE were compared. Risk factors for drain contamination were assessed using multi-level modelling. FINDINGS: Of 1209 exposed patient room and communal shower room drains, 53 (4%) yielded 62 CPE isolates in seven (70%) hospitals. Of 49 CPE isolates in patient room drains, four (8%) were linked to prior room occupants. Linked drain/room occupant pairs included Citrobacter freundii ST18 isolates separated by eight single nucleotide variants (SNVs), related blaKPC-containing IncN3-type plasmids (different species), related blaKPC-3-containing IncN-type plasmids (different species), and related blaOXA-48-containing IncL/M-type plasmids (different species). In one hospital, drain isolates from eight rooms on two units were Enterobacter hormaechei separated by 0-6 SNVs. Shower drains were more likely to be CPE-contaminated than hand hygiene (odds ratio: 3.45; 95% confidence interval: 1.66-7.16) or patient-use (13.0; 4.29-39.1) sink drains. Hand hygiene sink drains were more likely to be CPE-contaminated than patient-use sink drains (3.75; 1.17-12.0). CONCLUSION: Drain contamination was uncommon but widely dispersed. Drain CPE unrelated to patient exposure suggests contamination by undetected colonized patients or retrograde (drain-to-drain) contamination. Drain types had different contamination risks.


Assuntos
Enterobacter/isolamento & purificação , Contaminação de Equipamentos , Hospitais , Quartos de Pacientes , Abastecimento de Água , Proteínas de Bactérias , Farmacorresistência Bacteriana , Infecções por Enterobacteriaceae/prevenção & controle , Humanos , Ontário , beta-Lactamases
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA